Loading...
HomeMy WebLinkAbout17070018.26:1 D D.2 D.3 D.9 E E.3 E.5 F.1 F.4 F.8 GA 10.9 - —� O - 01- aOJ TU -2.3 > O O WHTR = O TU -21 1 10 TU -2.2 I TU -2.4 - -- 0- O OTU -C2 3 2 (/ PROJECTOR y - -r-- - jjTU-C2 10F 5 ® !� 7/ -- n 3 } UP I: WAP r EXISTING F DH THEATER k ME ROOM g,I 0 EWC EXIST. MEN'S RESTROOM EXIST. WOMENS O RESTROOM G.8 H.1 O O VESTIBULE (OPEN TO BELOW) - H.7 J.1 EWHTRO-, LEM 0 0 0 � o r O O O C O EXIST, EXIST. ELEVATOR ELEVATOR 1 ELECTRICAL DEMOLITION PLAN ' E102 118" = 1'-0" 7 � 0' 4' 8' 16' 0 EXIT 0I 16 SPECIALTY SYSTEMS: SECURITY SYSTEM THE SYSTEM COMPONENTS SHALL BE THE RESPONSIBLITY OF THE OWNER OR OWNER'S SUBCONTRACTOR. EXISTING COMPONENTS MAY REMAIN OR MAY BE REMOVED, COORDINATE WITH THE OWNERS SUBCONTRACTOR, 15.4 GENERAL DEMOLITON NOTES [ GENERAL DEMOLITION CONTRACTOR SHALL, EXCEPT WHERE OTHERWISE NOTED OR SHOWN, REMOVE EXISTING LIGHTING IN THIS AREA. ALL EXISTING WORK IS INDICATED AS COMPLETE AS POSSIBLE; CONTRACTOR SHALL SITE VERIFY ALL EXISTING CONDITIONS. EXISTING DEVICE QUANTITIES, EXACT LOCATION, EXACT WIRING METHOD MAY NOT BE AS IT APPEARS ON THIS DRAWING, VERIFY 18.1 ACTUAL CONDITIONS AT PROJECT SITE FOR EACH ROOM & LOCATION. GENERAL DEMOLITION AND REMOVAL. PROJECT COORDINATION: 18 CONSULT THE ARCHITECTURAL, MECHANICAL, PLUMBING, AND OTHER DRAWINGS FOR SCOPE OF THIS PROJECT, COORDINATION OF WORK WITH ALL TRADES, SCOPE AND ADDITIONAL WORK RELATING TO ELECTRICAL WORK INDICATED. WHERE THERE IS A 17.9 CONFLICT FOR SPACE WITH OTHER TRADES, OR SPACE ALLOCATIONS ARE NOT ADEQUATE, IDENTIFY THE SCOPE OF THE PROBLEM WITH THE ARCHITECT/ENGINEER FOR A DIRECTIVE BEFORE THE INSTALLATION OF EQUIPMENT IS STARTED. EXISTING WIRING, COMPONENTS & DEVICES: THE DRAWINGS REPRESENTS A GENERAL SCHEME OF EXISTING CONDITIONS. ALL ELECTRICALLY DISCONNECT EQ THAT IS TO BE REMOVED; MOST MECHANICAL & PLUMBING EQUIPMENT IS TO DETAILS OF THE EXISTING CONDITIONS MAY NOT APPEAR ON THE DRAWINGS. EACH CONTRACTOR SHALL VISIT THE SITE TO 17.5 IDENTIFY ALL WORK INCLUDING THE FOLLOWING: 15.5 DISCONNECTION OF ALL EQUIPMENT THAT IS TO BE RELOCATED OR REMOVED FROM SERVICE. EQUIPMENT IS TO BE BE REMOVED MAINTAIN CIRCUIT CONTINUITY FOR ALL EQUIPMENT THAT IS TO REMAIN IN DISCONNECTION AND REMOVAL OF ALL EQUIPMENT THAT IS NOT TO BE REUSED. RECONNECTION AF ALL EXISTING EQUIPMENT THAT IS TO BE RELOCATED. MAINTAINING CIRCUIT CONTINUITY FOR ALL EXISTING EQUIPMENT THAT IS TO REMAIN. WHICH ARE SERVED FROM THIS AREA OR PASS THROUGH THIS AREA, PROVIDE BLANK COVERPLATES FOR ALL MAINTAIN ALL OPERATING EQUIPMENT, DEVICES AND COMPONENTS COMPLETE AND OPERATIONAL IN ACCORDANCE WITH THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS. GENERAL ITEMS: PROVIDE BLANK COVERPLATES FOR ALL REMOVED DEVICES AND OTHER OPEN JUNCTION BOXES BEFORE CONDUCTORS. JUNCTION BOXES, ETC. IN THIS AREA. COMPLETION OF THE PROJECT. 2O DEMOLITION COMPONENTS: REVEIW DEVICES TO BE REMOVED WITH THE OWNER BEFORE REMOVAL FROM THE 17 PROJECT SITE. EXISTING COMPONENTS MAY WANT TO BE RETAINED BY THE OWNER, NOT LIMITED TO BUT REMOVE, STORE, REINSTALL, AND RECONNECT EXISTING DEVICE. SEE LIGHTING, POWER, OR SYSTEMS PLAN. INCLUDING ITEMS INDICATED ON THE PLANS. O CONDUITS AND WIRING: REUSE OF EXISTING CONDUIT IN PLACE IS PERMITTED WHERE SUCH USE IS WITHIN THE LIMITS OF THE NATIONAL ELECTRICAL REMOVE AND DELIVER TO OWNER UNDAMAGED. IF IT IS A COMPONENT OF ANOTHER TRADE, UNIT SHALL BE CODE; OF ADEQUATE SIZE FOR THE INTENDED USE, AND IN GOOD CONDITION WITHOUT DENTS, OBSTRUCTIONS, ETC. 16.5 REMOVE ALL EXISTING ABANDONED WIRING AND ALL ACCESSIBLE ABANDONED CONDUIT WHICH ARE NO LONGER REQUIRED, UNLESS OTHERWISE NOTED. EXISTING IDF. AT NEW CONSTRUCTION, ABANDONED CONDUITS SHALL BE REMOVED CLEAR OF NEW CONSTRUCTION AND FINISHES. CUT OFF FLUSH OR WHERE CONDUIT ENTERS DEMOLISHED AREAS. 16 SPECIALTY SYSTEMS: SECURITY SYSTEM THE SYSTEM COMPONENTS SHALL BE THE RESPONSIBLITY OF THE OWNER OR OWNER'S SUBCONTRACTOR. EXISTING COMPONENTS MAY REMAIN OR MAY BE REMOVED, COORDINATE WITH THE OWNERS SUBCONTRACTOR, 15.4 DEMOLITION PLAN NOTES [ (D CONTRACTOR SHALL, EXCEPT WHERE OTHERWISE NOTED OR SHOWN, REMOVE EXISTING LIGHTING IN THIS AREA. 60% DISCONNECT POWER TO ALL ELECTRICAL EQUIPMENT AND DEVICES, IN WALLS INDICATED TO BE REMOVED, FOR 20 GENERAL DEMOLITION AND REMOVAL. BID THE EC SHALL DISCONNECT POWER TO EQUIPMENT FOR GENERAL DEMOLITION AND REMOVAL. REMOVE EXISTING OUTLETS IN WALLS WHICH ARE INDICATED TO BE REMOVED. IN THE AREAS OF REMODEL, NEW OUTLETS WILL BE 21 INSTALLED, REMOVE ALL EXISTING OUTLETS, REVIEW ARCHITECTURAL. MECHANICAL & PLUMBING DRAWINGS AND ELECTRICALLY DISCONNECT EQ THAT IS TO BE REMOVED; MOST MECHANICAL & PLUMBING EQUIPMENT IS TO REMAIN IN SERVICE (DO NOT DISCONNECT FROM THE ELECTRICAL SYSTEM); WHERE OWNER, MECH & PLUMBING 15.5 EQUIPMENT IS TO BE BE REMOVED MAINTAIN CIRCUIT CONTINUITY FOR ALL EQUIPMENT THAT IS TO REMAIN IN USE. PROVIDE CIRCUIT CONTINUITY FOR ALL FEEDERS, BRANCH CIRCUITS. OUTLETS, LIGHTING FIXTURES, ETC. WHICH ARE SERVED FROM THIS AREA OR PASS THROUGH THIS AREA, PROVIDE BLANK COVERPLATES FOR ALL JUNCTION BOXES ABANDONED IN WALLS THAT ARE TO REMAIN. REMOVE ALL ABANDONED CONDUIT, CONDUCTORS. JUNCTION BOXES, ETC. IN THIS AREA. 2O EXISTING DEVICE TO REMAIN. O REMOVE, STORE, REINSTALL, AND RECONNECT EXISTING DEVICE. SEE LIGHTING, POWER, OR SYSTEMS PLAN. O ELECTRICALLY DISCONNECT DEVICE AS LISTED ADJACENT PLAN NOTE. IF IT IS AN ELECTRICAL COMPONENT, REMOVE AND DELIVER TO OWNER UNDAMAGED. IF IT IS A COMPONENT OF ANOTHER TRADE, UNIT SHALL BE REMOVED BY THAT TRADE. O EXISTING IDF. PROJECT LOCATION 1 i KEY PLAN N.T.S. Woo Architecture 1 1 7635 Intera Suite 100 Indianapoli 317.299.751 A P. Q Cit) J Q z Q UDW LL C a Cr z LL LL Z L z LL LL Q W LL C/) V REV DATE [ 02/28/2017 60% 03/13/2017 75% 04/04/2017 BID Proj. No.: Date: Sheet Nam DEMOL PLAN EI