Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17070018.27
C.8 D D.2 D.3 10.9 B-1616&16 f Ei-1E TEAK I - SEPW-1 D.9 E E.3 E.5 F.1 F.4 F.8 GA G.8 H.1 H.7 J.1 10. - 1 Op OC Oc On CORRIDOR SEPW-3 4 207 10 _ 77 9.7r� LUMINAIRE SCHEDULE Symbol Oty Label 24 A 8 8 B --_ 4 O 4 D 10 E 4 IF 16 t3 I 3 8-12 EM ® X1 ® X2 WIKt IU EXISTING EXIT LIGHT CIRCUIT IN ROOM SEP EXISTING THEATER ME Room AL &16 EXIS. CHASE 41 -- 6 ILI-3 EXIST. WOMEN" RESTROOM ILI-22 1 LIGHTING PLAN " E103 1/8" = V-0" 0' 4' 8' 16' Arrangement Description SINGLE HRZ-4-LED-5050-FL-SS-35 Lum. Watts Total Watts Lum. Lumens 80.8 3693 SINGLE LED TAPE LIGHT - 1 FT SECTION - 3.4 WATTS PER FOOT 255 LUMENS PER FOOT 13.4 50.6 GROUP 16FT SECTION OF TYPE B LED TAPE N.A. 435.2001 SINGLE LINEA 3600 04 MO/MO 835 FF COLOR 010 MOUNTING 62,5 250 -...._____ ... .._. SINGLE IMG99 835 00 00 UNV 010 - SEMI RECESSED 20 s0 SINGLE SOSSF03LED-OCIOL-E1-H12-SD3F-OC10L-35K-42-MW-SO RECESSED 20 1200 SINGLE DRUM PENDANT- 3000 LUMENS - DIFFUSED DISTRIBUTION }36.7 146.8 SINGLE 1 COUNTER PENDANT - 8 WATTLED OR EQUAL TO 5OWMR16 8 120 GROUP 12FT SECTION OF TYPE 8 LED TAPE i N.A. 122.4 SINGLE LITHONIA ELM2 LED - 120/277V - WHITE SURE-LITES ES713 SURFACE MOUNTED EDGE -LIT SINGLE FACE EXIT SIGN WITH RED LETTERS (ARROWS)AS INDICATED ON THE DRAWINGS AND LED LAMPS WITH EM BATTERY SURE-LITES ES723 SURFACE MOUNTED EDGE -LIT DOUBLE FACE EXIT SIGN WITH RED LETTERS (ARROWS)AS INDICATED ON THE DRAWINGS AND LED LAMPS WITH EM BATTERY 255 N.A. 3693 1028 1026 3693 1026 N.A. EXFT 'E-5_, 20 21 CONNECTIONS TO EXISTING BLDG & INSTALLATION REQUIREMENTS: ATTACHMENT TO, SUSPENSION FROM, OR PENETRATION OF EXISTING BUILDING STRUCTURE, FLOOR DECK, OR ROOF DECK IS NOT PERMITTED WITHOUT PRIOR APPROVAL, ALL ATTACHMENTS TO THE EXISTING BUILDING STRUCTURE SHALL 15.5 BE MADE USING NON-DESTRUCTIVE METHODS, SUSPENDED FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL. DO NOT DRILL, WELD, SCREW, OR SHOOT INTO THE EXISTING STRUCTURE. PLAN NOTES O REMOVE, STORE. REINSTALL. AND RECONNECT EXISTING DEVICE AT THIS LOCATION RECONNECT TO EXISTING WIRING SERVING DEVICE AS REQUIRED. SEE DEMOLITION PLAN. O EXISTING DEVICE TO REMAIN. OWIRE 4' SECTION OF'B' LIGHTING TO NL CIRCUIT, WIRED WITH EXIT LIGHTS AND EMERGENCY LIGHTING AS INDICATED. THIS SECTION IS NOT TO BE SWITCHED. ®PROVIDE WALL SWITCH(ES) TO TURN OFF OVERHEAD LIGHTS (LIGHTS TURN ON WITH SENSOR & SWITCH MUST BE ON FOR SENSOR TO OPERATE). THIS IS TO ALLOW USERS TO TURN OFF LIGHTS IF NEEDED FOR PRESENTATIONS. IF 2 SWITCHES ARE INDICATED, WIRE ONE SWITCH TO PENDANT FIXTURES AND OTHER SWITCH TO DOWNLIGHTS IN THIS ROOM. LABEL SWITCHES. OMAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS THROUGH AREA REWIRED TO NEW PANEL. VERIFY EXACT LOCATION OF EXISTING CIRCUIT ROUTING AT JOB SITE AND EXTEND AS REQUIRED. EXISTING CIRCUIT ON ORIGINAL PLANS INDICATED ADJACENT PLAN NOTE. ©MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS SERVING THIS AREA, FED ON SAME EXISTING CIRCUIT AS THE TO BE REWIRED BATHROOMS. VERIFY EXACT LOCATION OF EXISTING CIRCUIT ROUTING AT JOB SITE AND EXTEND AS REQUIRED. EXISTING CIRCUIT ON ORIGINAL PLANS INDICATED ADJACENT PLAN NOTE, OREWIRE ALL EXISTING LIGHTING DEVICES IN THIS ROOM TO NEW SEP PANEL AS INDICATED ADJACENT PLAN NOTE. MAINTAIN SWITCHING AND NIGHT LIGHTS AS PRESENTLY WIRED. PROJECT LOCATION =- 7J, KEY PLAN C - - N.T.S. Wool Architecture I E 7635 Interw Suite 100 Indianapolis 317.299.750 4tN1~I A Pu R Q u City I J Q Z W LL a z w LL z L z LL LL a 0. � W LL V) Cr. REV DATE I 02/28/2017 60% 03/13/2017 75% 04/04/2017 BID Proj. No.: Date: Sheet Narr LIGHIT PLAN E' GENERAL NOTES ' INSTALLATION & WORK SHALL MEET CURRENT NEC ADOPTED BY THE AGENCY OF AUTHORITY & SHALL COMPLY WITH ALL LOCAL REGULATIONS. ALL COMPONENTS SHALL UL LISTED FOR THE APPLICATION. t ALL CONTRACTORS SHALL REFER TO THE PROJECT "GENERAL CONDITIONS" FOR PHASING AND ALLOWABLE WORK HOUR INSTRUCTIONS. ELECTRICAL DISTRIBUTION COMPONENTS: PROVIDE UL LISTED COMPONENTS INSTALLED WITHIN THEIR RATINGS. NEW PANELBOARDS SHALL BE COMMERCIAL GRADE WITH BOLTIN BREAKERS. 18.1 WIRING DEVICES & COVERPLATES ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE. 18 ALL DEVICES INSTALLED IN OCCUPIED AREAS (INCLUDING HALLS, CORRIDORS. PUBLIC AREAS) SHALL BE INSTALLED FLUSH WITH DRYWALL WITH CONCEALED CONDUITS. 17.9 ALL DEVICES IN SERVICE ROOMS (MECH, ELEC, ELEV, ETC.) MAY BE INSTALLED SURFACE MOUNTED WITH SURFACE CONDUITS. COVERPLATES & DEVICES IN OCCUPIED AREAS SHALL BE COLOR AS SELECTED BY THE OWNER'S REPRESENTATIVE. 17.5 DEVICE LOCATIONS • DO NOT INSTALL BACK BOXES BACK TO BACK AT ANY LOCATION. INSTALL DEVICES ON OPPOSITE SIDES OF WALL STUDS. ALL WALL DEVICE LOCATIONS INDICATED ARE APPROXIMATE LOCATIONS, COORDINATE WITH THIS REQUIREMENT AT THE PROJECT SITE. • ALL WALL DEVICE LOCATIONS INDICATED ARE APPROXIMATE LOCATIONS REVIEWED WITH THE ARCHITECT. ELECTRICAL CONTRACTOR SHALL PREPARE A MOCK-UP IN ONE ROOM (FOR EACH TYPE OF UNIT) WITH LOCATIONS OF ALL DEVICES, FOR APPROVAL BY THE ARCHITECT. DO NOT PROCEED WITH ROUGH -IN UNTIL APPROVAL IS RECEIVED FROM ARCHITECT. BRANCH CIRCUIT WIRING/INSTALLATION ` CONDUCTOR & CONDUIT SIZES ARE BASED ON THHN CONDUCTORS & EMT CONDUIT. COORDINATE PROPER SIZE WITH INSTALLATION REQUIREMENTS & ALTERNATIVE CONDUCTOR & CONDUIT TYPE IF DIFFERENT THAN BASIS. 17 ` ALL DEVICES AND EQUIPMENT SHOWN ON THE PLANS ARE NEW UNLESS NOTED OTHERWISE. PROVIDE ALL NEW DEVICES AS SHOWN OR NOTED AND CONNECT TO PANELBOARD SERVING THE AREA AS REQUIRED, AS SHOWN, OR LISTED WITH APPROVED WIRING METHODS AS PER SPECIFICATIONS. 16.5 • BRANCH CIRCUITS SHALL BE INSTALLED IN WALLS AND ABOVE CEILINGS WHERE EVER POSSIBLE. MINIMIZE ROUTING OF CONDUITS IN FLOOR SLAB. CONDUITS BELOW SLAB TERMINATING AT THE PANELBOARD SHALL BE INSTALLED 24" BELOW FINISHED FLOOR. ' ALL 20 AMPERE, 120 VOLT BRANCH CIRCUIT HOME RUN CONDUCTORS SHALL BE SIZED TO MAINTAIN A MAXIMUM OF 3 PER CENT VOLTAGE DROP AT FULL LOAD. ALL EXTENDED CIRCUITS, SWITCH LEGS, ETC. SHALL BE CALCULATED TO MAINTAIN THE MAXIMUM VOLTAGE DROP. 16 AS A GUIDE THE FOLLOWING TABLE MAY BE USED AS A REFERENCE FOR BASIC SIMPLE BRANCH CIRCUITS. WIRING ORIGINATING AT PANELBOARD SHALL BE SIZED AS A MINIMUM OF THIS TABLE. NEAR THE END OF THE CIRCUIT, THE LAST 40' OF BRANCH CIRCUIT FROM LAST OUTLET CONNECTION TOWARDS PANELBOARD MAY BE #12. ALSO WIRE TAILS OF #12 MAY BE USED IN SHORT (20' LENGHTS) ALONG THE MAIN CIRCUIT TO SERVE DEVICES & BOXES. WIRING SCHEDULE GUIDE: DISTANCE CONDUCTOR CONDUIT SIZE FOR SIZES 4 WIRE CIRCUIT 0-60 FT #12/#12G .75"C 15.4 60-100 FT #10/#10G .75"C 100-150 FT #8/#10G .75"C 150-230 FT #6/#10G 1"C 230+ FT #4/#8G 1 "C SIZE CONDUITS FOR ACTUAL WIRING CONDITION, 20 21 CONNECTIONS TO EXISTING BLDG & INSTALLATION REQUIREMENTS: ATTACHMENT TO, SUSPENSION FROM, OR PENETRATION OF EXISTING BUILDING STRUCTURE, FLOOR DECK, OR ROOF DECK IS NOT PERMITTED WITHOUT PRIOR APPROVAL, ALL ATTACHMENTS TO THE EXISTING BUILDING STRUCTURE SHALL 15.5 BE MADE USING NON-DESTRUCTIVE METHODS, SUSPENDED FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL. DO NOT DRILL, WELD, SCREW, OR SHOOT INTO THE EXISTING STRUCTURE. PLAN NOTES O REMOVE, STORE. REINSTALL. AND RECONNECT EXISTING DEVICE AT THIS LOCATION RECONNECT TO EXISTING WIRING SERVING DEVICE AS REQUIRED. SEE DEMOLITION PLAN. O EXISTING DEVICE TO REMAIN. OWIRE 4' SECTION OF'B' LIGHTING TO NL CIRCUIT, WIRED WITH EXIT LIGHTS AND EMERGENCY LIGHTING AS INDICATED. THIS SECTION IS NOT TO BE SWITCHED. ®PROVIDE WALL SWITCH(ES) TO TURN OFF OVERHEAD LIGHTS (LIGHTS TURN ON WITH SENSOR & SWITCH MUST BE ON FOR SENSOR TO OPERATE). THIS IS TO ALLOW USERS TO TURN OFF LIGHTS IF NEEDED FOR PRESENTATIONS. IF 2 SWITCHES ARE INDICATED, WIRE ONE SWITCH TO PENDANT FIXTURES AND OTHER SWITCH TO DOWNLIGHTS IN THIS ROOM. LABEL SWITCHES. OMAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS THROUGH AREA REWIRED TO NEW PANEL. VERIFY EXACT LOCATION OF EXISTING CIRCUIT ROUTING AT JOB SITE AND EXTEND AS REQUIRED. EXISTING CIRCUIT ON ORIGINAL PLANS INDICATED ADJACENT PLAN NOTE. ©MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS SERVING THIS AREA, FED ON SAME EXISTING CIRCUIT AS THE TO BE REWIRED BATHROOMS. VERIFY EXACT LOCATION OF EXISTING CIRCUIT ROUTING AT JOB SITE AND EXTEND AS REQUIRED. EXISTING CIRCUIT ON ORIGINAL PLANS INDICATED ADJACENT PLAN NOTE, OREWIRE ALL EXISTING LIGHTING DEVICES IN THIS ROOM TO NEW SEP PANEL AS INDICATED ADJACENT PLAN NOTE. MAINTAIN SWITCHING AND NIGHT LIGHTS AS PRESENTLY WIRED. PROJECT LOCATION =- 7J, KEY PLAN C - - N.T.S. Wool Architecture I E 7635 Interw Suite 100 Indianapolis 317.299.750 4tN1~I A Pu R Q u City I J Q Z W LL a z w LL z L z LL LL a 0. � W LL V) Cr. REV DATE I 02/28/2017 60% 03/13/2017 75% 04/04/2017 BID Proj. No.: Date: Sheet Narr LIGHIT PLAN E'