Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
17070018.28
AIR D D.2 D.3 _ 1. 10.9 SEPW-11--' ,77 TEAM 06 ROOM 206 \ S EP W-7 SEPW-9 S C Nr� D.9 E E.3 E.5 F.1 F.4 F.8 GA 11 TEAM 65 TABLE TEAM k TABLE 1 I 1--- I TEAM i3 T E TEAM 62 TABLE SEPW-2,40 SEPW-6,8 O3 F SEPW-2,4/3 SEPW-6,803 6 v CD DO 0o v oo w o0 (0 N in LO(D to iTrT)� CO N in Lr) CD CO LO U')CO ( LL CORRIDOR 1 207 SEPW-10 2 BALL 48 AFF - — _ 10 D 141 EXISTING THEATER MECHANICAL ROOM SEPE-5,7,9 EPE-17 SEPE-19 IDEATION ROOM 204 SEPE-15 LExls. CHASE EXISTING SPACE IDEATION 4,171 SQ.FT 202 ION ROOM 203 WORK BENCH SEPE 0 T z Q EXIST. MENS RESTROOM 8 EXIST. WOMEN'S RESTROOM SEPE-23 POWER AND SYSTEM PLAN " E104 1/8" = V-0" G.8 H.1 H.7 J.1 OUTSIDE TEAM - - 47.5 VESTIBULE (OPEN TO BELOW) COORDINATE THE EXACT TTABLE 44, A SEPW-20 LOCATION OF THESE 2 7 2 7 2 9 9 2 CONDUITS TO ALLOW INSTALLATION OF LOW 16y , VOLTAGE CABLES TO THE SEPE-16,18 EXISTING SEP OFFICE ON THE 3RD FLOOR OF THIS BUILIDNG COMMONS 209 — 17 EXIT F CHASE EXIS. 800TH WS BOOTH 47 BOOTH 92 BOOTH K1 SECURED ENTRANCE 13 _�y % SEPW-11,13 ELVR OR 1 J EWHTR F SEPE-25 EXIT EXIST. EXIST. ELEVATOR ELEVATOR — - - -- 7 0' 4' 8' 16' NOTE: EC SHALL REWIRE ALL EXISTING OUTLETS WITH REMODELED SPACE TO NEW PANELBOARDS. 16.5 16 15.4 --20' 15.5 PROJECT LOCATION A: i' -p. --- KEY PLAN N.T.S. GENERAL NOTES • INSTALLATION & WORK SHALL MEET CURRENT NEC ADOPTED BY THE AGENCY OF AUTHORITY & SHALL COMPLY WITH ALL LOCAL REGULATIONS. ' ALL COMPONENTS SHALL UL LISTED FOR THE APPLICATION. ALL CONTRACTORS SHALL REFER TO THE PROJECT "GENERAL CONDITIONS" FOR PHASING AND ALLOWABLE WORK HOUR INSTRUCTIONS ELECTRICAL DISTRIBUTION COMPONENTS: PROVIDE UL LISTED COMPONENTS INSTALLED WITHIN THEIR RATINGS. NEW PANELBOARDS SHALL BE COMMERCIAL GRADE WITH BOLTIN BREAKERS. WIRING DEVICES & COVERPLATES " ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE. ALL DEVICES INSTALLED IN OCCUPIED AREAS (INCLUDING HALLS, CORRIDORS, PUBLIC AREAS) SHALL BE INSTALLED FLUSH WITH DRYWALL WITH CONCEALED CONDUITS. ALL DEVICES IN SERVICE ROOMS (MECH, ELEC, ELEV, ETC.) MAY BE INSTALLED SURFACE MOUNTED WITH SURFACE CONDUITS. COVERPLATES & DEVICES IN OCCUPIED AREAS SHALL BE COLOR AS SELECTED BY THE OWNER'S REPRESENTATIVE. DEVICE LOCATIONS DO NOT INSTALL BACK BOXES BACK TO BACK AT ANY LOCATION. INSTALL DEVICES ON OPPOSITE SIDES OF WALL STUDS. ALL WALL DEVICE LOCATIONS INDICATED ARE APPROXIMATE LOCATIONS, COORDINATE WITH THIS REQUIREMENT AT THE PROJECT SITE. ' ALL WALL DEVICE LOCATIONS INDICATED ARE APPROXIMATE LOCATIONS REVIEWED WITH THE ARCHITECT. ELECTRICAL CONTRACTOR SHALL PREPARE A MOCK-UP IN ONE ROOM (FOR EACH TYPE OF UNIT) WITH LOCATIONS OF ALL DEVICES, FOR APPROVAL BY THE ARCHITECT. DO NOT PROCEED WITH ROUGH -IN UNTIL APPROVAL IS RECEIVED FROM ARCHITECT. BRANCH CIRCUIT WIRING/INSTALLATION ` CONDUCTOR & CONDUIT SIZES ARE BASED ON THHN CONDUCTORS & EMT CONDUIT. COORDINATE PROPER SIZE WITH INSTALLATION REQUIREMENTS & ALTERNATIVE CONDUCTOR & CONDUIT TYPE IF DIFFERENT THAN BASIS. • ALL DEVICES AND EQUIPMENT SHOWN ON THE PLANS ARE NEW UNLESS NOTED OTHERWISE. PROVIDE ALL NEW DEVICES AS SHOWN OR NOTED AND CONNECT TO PANELBOARD SERVING THE AREA AS REQUIRED, AS SHOWN, OR LISTED WITH APPROVED WIRING METHODS AS PER SPECIFICATIONS. • BRANCH CIRCUITS SHALL BE INSTALLED IN WALLS AND ABOVE CEILINGS WHERE EVER POSSIBLE. MINIMIZE ROUTING OF CONDUITS IN FLOOR SLAB. CONDUITS BELOW SLAB TERMINATING AT THE PANELBOARD SHALL BE INSTALLED 24" BELOW FINISHED FLOOR. ALL 20 AMPERE, 120 VOLT BRANCH CIRCUIT HOME RUN CONDUCTORS SHALL BE SIZED TO MAINTAIN A MAXIMUM OF 3 PER CENT VOLTAGE DROP AT FULL LOAD. ALL EXTENDED CIRCUITS, SWITCH LEGS, ETC. SHALL BE CALCULATED TO MAINTAIN THE MAXIMUM VOLTAGE DROP. AS A GUIDE THE FOLLOWING TABLE MAY BE USED AS A REFERENCE FOR BASIC SIMPLE BRANCH CIRCUITS, WIRING ORIGINATING AT PANELBOARD SHALL BE SIZED AS A MINIMUM OF THIS TABLE, NEAR THE END OF THE CIRCUIT, THE LAST 40' OF BRANCH CIRCUIT FROM LAST OUTLET CONNECTION TOWARDS PANELBOARD MAY BE #12. ALSO WIRE TAILS OF #12 MAY BE USED IN SHORT (20' LENGHTS) ALONG THE MAIN CIRCUIT TO SERVE DEVICES & BOXES. WIRING SCHEDULE GUIDE: DISTANCE CONDUCTOR CONDUIT SIZE FOR SIZES 4 WIRE CIRCUIT 0-60 FT #121#12G .75"C 60-100 FT #10/#10G .75"C 100-150 FT #8/#10G .75"C 150-230 FT #6/#10G 1"C 230+ FT #4/#8G 1"C SIZE CONDUITS FOR ACTUAL WIRING CONDITION. CONNECTIONS TO EXISTING BLDG & INSTALLATION REQUIREMENTS: ATTACHMENT TO, SUSPENSION FROM, OR PENETRATION OF EXISTING BUILDING STRUCTURE, FLOOR DECK, OR ROOF DECK IS NOT PERMITTED WITHOUT PRIOR APPROVAL. ALL ATTACHMENTS TO THE EXISTING BUILDING STRUCTURE SHALL BE MADE USING NON-DESTRUCTIVE METHODS, SUSPENDED FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL. DO NOT DRILL, WELD, SCREW, OR SHOOT INTO THE EXISTING STRUCTURE. LOW VOLTAGE CABLE & INSTALLATION REQUIREMENTS: ALL DATAIPHONENIDEO CABLING AND SYSTEM COMPONENTS ARE BY THE OWNERS VENDOR. PLENUM RATED CABLE MUST BE USED ABOVE THE CEILING OF ROOM 205. ALL OTHER AREAS MAY USE NON -PLENUM RATED CABLES. PLAN NOTES U REMOVE, STORE, REINSTALL, AND RECONNECT EXISTING DEVICE AT THIS LOCATION. RECONNECT TO EXISTING WIRING SERVING DEVICE AS REQUIRED. SEE DEMOLITION PLAN. O EXISTING DEVICE TO REMAIN. O INSTALL SINGLE DUPLEX & DATA ROUGH -IN CENTERED ON WALL AT 5'0"AFF FOR TV MONITOR. INSTALL DOUBLE DUPLEX AND 6PLEX DATA ROUGHIN V FROM EAST END OF WALL FOR TABLE POWER. 6PLEX DATA ROUGHIN SHALL USE 1 1/4"C TO ABOVE CEILING. EACH DUPLEX (IN DOUBLE DUPLEX BOX) SHALL BE WIRED TO SEPARATE CIRCUIT, OINSTALL SINGLE DUPLEX & DATA ROUGH -IN CENTERED ON WALL AT 50"AFF FOR TV MONITOR, COORDINATE WITH TV VENDOR AND ARCHITECTURAL ELEVATIONS. OFOR POWER AND LOW VOLTAGE OUTLETS PROVIDE WIREMOLD 4000 INSTALLED CONTINUOUSLY BELOW COUNTER. PROVIDE A DIVIDER WITH A DUPLEX OUTLET INSTALLED AS INDICATE ABOVE DIVIDER. DIVIDE OUTLETS BETWEEN BRANCH CIRCUITS INDICATED. ALL LOW VOLTAGE OUTLETS SHALL BE INSTALLED BELOW DIVIDER. PROVIDE OUTLETS AS INDICATED (DATA QUANTITIES INDICATED). OWNER MAY USE RACEWAY FOR ALL COMMUNICATION CABLES AS REQUIRED. PROVIDE BLANK PLATES OVER ALL UNUSED POSITIONS. TABLE HAS 2 COUNTER HEIGHTS, PROVIDE WM4000 OFFSETS OR CONDUIT CONNECTIONS AS REQUIRED FOR POWER, DATA CABLES MAY BE RUN EXPOSED IF PROTECTED FROM EDGES OF WM. LEAVE COVERS OFF WM UNTIL OWNERS VENDOR HAS INSTALL DATA CABLES AND OUTLETS. PROVIDE BOX/COVERPLATE SUPPORT FOR DATA OUTLETS, OWNERS VENDOR SHALL PROVIDE STANDARD BOX STRAP TYPE OUTLETS AND COVERPLATES FOR HIS DEVICES. ©PROVIDE 1.5" CONDUIT IN WALL TO ABOVE CEILING IF POSSIBLE, OTHERWISE PROVIDE WIREMOLD 4000 INSTALLED CONTINUOUSLY TO ABOVE CEILING AT OR NEAR THIS LOCATION. NO OUTLETS TO BE INSTALLED IN VERTICAL SECTION. CONNECT TO WM IN TABLE AREA LEAVE COVERS OFF WM UNTIL OWNERS VENDOR HAS INSTALL DATA CABLES AND OUTLETS. O MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS SERVING THIS AREA, FED ON SAME EXISTING CIRCUIT AS THE TO BE REWIRED BATHROOMS. VERIFY EXACT LOCATION OF EXISTING CIRCUIT ROUTING AT JOB SITE AND EXTEND AS REQUIRED. EXISTING CIRCUIT ON ORIGINAL PLANS INDICATED ADJACENT PLAN NOTE. ® REWIRE ALL EXISTING OUTLET DEVICES IN THIS ROOM TO NEW SEP PANEL AS INDICATED ADJACENT PLAN NOTE. MAINTAIN SWITCHING AND NIGHT LIGHTS AS PRESENTLY WIRED. Og REWIRE EXISTING DEVICE AS LISTED ADJACENT PLAN NOTE TO NEW SEP PANEL AS INDICATED 10 PROVIDE (1) 3" CONDUIT IN FLOOR TO ABOVE ACCESSIBLE CEILING OF FLOOR BELOW FOR INSTALLATION OF LOW VOLTAGE CABLES. PROVIDE (3) 3" CONDUITS ABOVE ACCESSIBLE CEILING FROM THIS ROOM INTO SUITE FOR INSTALLATION OF LOW VOLTAGE CABLES. PROVIDE 314" THICK FIRE RESISTANT PLYWOOD BACKBOARD FOR OF COMPONENTS (CONTRACTOR MAY USE EXISTING PLYWOOD IF NOT DAMAGED). CLOSE INTERIOR OF ALL CONDUITS WITH FIRE RATED MATERIAL AFTER ALL CABLES ARE INSTALLED. 11 PROVIDE (3)4' CONDUITS THROUGH FIRE WALL, LOCATE ABOVE THE ACCESSIBLE CEILINGS FOR INSTALLATION OF LOW VOLTAGE CABLES. CLOSE INTERIOR OF CONDUITS INSTALLED IN FIRE WALLS WITH FIRE RATED MATERIAL AFTER ALL CABLES ARE INSTALLED. %A WOOLI Architecture I Engine 7635 Interactive Suite 100 Indianapolis, IN 317.299.7500 O�vE%-OPN A Public / F Partners u City Of C India 'Q No. * ARI 9600 STATE I ND A� /"1 9RCHiT' VJ C DES, 02/28/2017 r Q L Z 75% PRE[ f S C Nr� D.9 E E.3 E.5 F.1 F.4 F.8 GA 11 TEAM 65 TABLE TEAM k TABLE 1 I 1--- I TEAM i3 T E TEAM 62 TABLE SEPW-2,40 SEPW-6,8 O3 F SEPW-2,4/3 SEPW-6,803 6 v CD DO 0o v oo w o0 (0 N in LO(D to iTrT)� CO N in Lr) CD CO LO U')CO ( LL CORRIDOR 1 207 SEPW-10 2 BALL 48 AFF - — _ 10 D 141 EXISTING THEATER MECHANICAL ROOM SEPE-5,7,9 EPE-17 SEPE-19 IDEATION ROOM 204 SEPE-15 LExls. CHASE EXISTING SPACE IDEATION 4,171 SQ.FT 202 ION ROOM 203 WORK BENCH SEPE 0 T z Q EXIST. MENS RESTROOM 8 EXIST. WOMEN'S RESTROOM SEPE-23 POWER AND SYSTEM PLAN " E104 1/8" = V-0" G.8 H.1 H.7 J.1 OUTSIDE TEAM - - 47.5 VESTIBULE (OPEN TO BELOW) COORDINATE THE EXACT TTABLE 44, A SEPW-20 LOCATION OF THESE 2 7 2 7 2 9 9 2 CONDUITS TO ALLOW INSTALLATION OF LOW 16y , VOLTAGE CABLES TO THE SEPE-16,18 EXISTING SEP OFFICE ON THE 3RD FLOOR OF THIS BUILIDNG COMMONS 209 — 17 EXIT F CHASE EXIS. 800TH WS BOOTH 47 BOOTH 92 BOOTH K1 SECURED ENTRANCE 13 _�y % SEPW-11,13 ELVR OR 1 J EWHTR F SEPE-25 EXIT EXIST. EXIST. ELEVATOR ELEVATOR — - - -- 7 0' 4' 8' 16' NOTE: EC SHALL REWIRE ALL EXISTING OUTLETS WITH REMODELED SPACE TO NEW PANELBOARDS. 16.5 16 15.4 --20' 15.5 PROJECT LOCATION A: i' -p. --- KEY PLAN N.T.S. GENERAL NOTES • INSTALLATION & WORK SHALL MEET CURRENT NEC ADOPTED BY THE AGENCY OF AUTHORITY & SHALL COMPLY WITH ALL LOCAL REGULATIONS. ' ALL COMPONENTS SHALL UL LISTED FOR THE APPLICATION. ALL CONTRACTORS SHALL REFER TO THE PROJECT "GENERAL CONDITIONS" FOR PHASING AND ALLOWABLE WORK HOUR INSTRUCTIONS ELECTRICAL DISTRIBUTION COMPONENTS: PROVIDE UL LISTED COMPONENTS INSTALLED WITHIN THEIR RATINGS. NEW PANELBOARDS SHALL BE COMMERCIAL GRADE WITH BOLTIN BREAKERS. WIRING DEVICES & COVERPLATES " ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE. ALL DEVICES INSTALLED IN OCCUPIED AREAS (INCLUDING HALLS, CORRIDORS, PUBLIC AREAS) SHALL BE INSTALLED FLUSH WITH DRYWALL WITH CONCEALED CONDUITS. ALL DEVICES IN SERVICE ROOMS (MECH, ELEC, ELEV, ETC.) MAY BE INSTALLED SURFACE MOUNTED WITH SURFACE CONDUITS. COVERPLATES & DEVICES IN OCCUPIED AREAS SHALL BE COLOR AS SELECTED BY THE OWNER'S REPRESENTATIVE. DEVICE LOCATIONS DO NOT INSTALL BACK BOXES BACK TO BACK AT ANY LOCATION. INSTALL DEVICES ON OPPOSITE SIDES OF WALL STUDS. ALL WALL DEVICE LOCATIONS INDICATED ARE APPROXIMATE LOCATIONS, COORDINATE WITH THIS REQUIREMENT AT THE PROJECT SITE. ' ALL WALL DEVICE LOCATIONS INDICATED ARE APPROXIMATE LOCATIONS REVIEWED WITH THE ARCHITECT. ELECTRICAL CONTRACTOR SHALL PREPARE A MOCK-UP IN ONE ROOM (FOR EACH TYPE OF UNIT) WITH LOCATIONS OF ALL DEVICES, FOR APPROVAL BY THE ARCHITECT. DO NOT PROCEED WITH ROUGH -IN UNTIL APPROVAL IS RECEIVED FROM ARCHITECT. BRANCH CIRCUIT WIRING/INSTALLATION ` CONDUCTOR & CONDUIT SIZES ARE BASED ON THHN CONDUCTORS & EMT CONDUIT. COORDINATE PROPER SIZE WITH INSTALLATION REQUIREMENTS & ALTERNATIVE CONDUCTOR & CONDUIT TYPE IF DIFFERENT THAN BASIS. • ALL DEVICES AND EQUIPMENT SHOWN ON THE PLANS ARE NEW UNLESS NOTED OTHERWISE. PROVIDE ALL NEW DEVICES AS SHOWN OR NOTED AND CONNECT TO PANELBOARD SERVING THE AREA AS REQUIRED, AS SHOWN, OR LISTED WITH APPROVED WIRING METHODS AS PER SPECIFICATIONS. • BRANCH CIRCUITS SHALL BE INSTALLED IN WALLS AND ABOVE CEILINGS WHERE EVER POSSIBLE. MINIMIZE ROUTING OF CONDUITS IN FLOOR SLAB. CONDUITS BELOW SLAB TERMINATING AT THE PANELBOARD SHALL BE INSTALLED 24" BELOW FINISHED FLOOR. ALL 20 AMPERE, 120 VOLT BRANCH CIRCUIT HOME RUN CONDUCTORS SHALL BE SIZED TO MAINTAIN A MAXIMUM OF 3 PER CENT VOLTAGE DROP AT FULL LOAD. ALL EXTENDED CIRCUITS, SWITCH LEGS, ETC. SHALL BE CALCULATED TO MAINTAIN THE MAXIMUM VOLTAGE DROP. AS A GUIDE THE FOLLOWING TABLE MAY BE USED AS A REFERENCE FOR BASIC SIMPLE BRANCH CIRCUITS, WIRING ORIGINATING AT PANELBOARD SHALL BE SIZED AS A MINIMUM OF THIS TABLE, NEAR THE END OF THE CIRCUIT, THE LAST 40' OF BRANCH CIRCUIT FROM LAST OUTLET CONNECTION TOWARDS PANELBOARD MAY BE #12. ALSO WIRE TAILS OF #12 MAY BE USED IN SHORT (20' LENGHTS) ALONG THE MAIN CIRCUIT TO SERVE DEVICES & BOXES. WIRING SCHEDULE GUIDE: DISTANCE CONDUCTOR CONDUIT SIZE FOR SIZES 4 WIRE CIRCUIT 0-60 FT #121#12G .75"C 60-100 FT #10/#10G .75"C 100-150 FT #8/#10G .75"C 150-230 FT #6/#10G 1"C 230+ FT #4/#8G 1"C SIZE CONDUITS FOR ACTUAL WIRING CONDITION. CONNECTIONS TO EXISTING BLDG & INSTALLATION REQUIREMENTS: ATTACHMENT TO, SUSPENSION FROM, OR PENETRATION OF EXISTING BUILDING STRUCTURE, FLOOR DECK, OR ROOF DECK IS NOT PERMITTED WITHOUT PRIOR APPROVAL. ALL ATTACHMENTS TO THE EXISTING BUILDING STRUCTURE SHALL BE MADE USING NON-DESTRUCTIVE METHODS, SUSPENDED FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL. DO NOT DRILL, WELD, SCREW, OR SHOOT INTO THE EXISTING STRUCTURE. LOW VOLTAGE CABLE & INSTALLATION REQUIREMENTS: ALL DATAIPHONENIDEO CABLING AND SYSTEM COMPONENTS ARE BY THE OWNERS VENDOR. PLENUM RATED CABLE MUST BE USED ABOVE THE CEILING OF ROOM 205. ALL OTHER AREAS MAY USE NON -PLENUM RATED CABLES. PLAN NOTES U REMOVE, STORE, REINSTALL, AND RECONNECT EXISTING DEVICE AT THIS LOCATION. RECONNECT TO EXISTING WIRING SERVING DEVICE AS REQUIRED. SEE DEMOLITION PLAN. O EXISTING DEVICE TO REMAIN. O INSTALL SINGLE DUPLEX & DATA ROUGH -IN CENTERED ON WALL AT 5'0"AFF FOR TV MONITOR. INSTALL DOUBLE DUPLEX AND 6PLEX DATA ROUGHIN V FROM EAST END OF WALL FOR TABLE POWER. 6PLEX DATA ROUGHIN SHALL USE 1 1/4"C TO ABOVE CEILING. EACH DUPLEX (IN DOUBLE DUPLEX BOX) SHALL BE WIRED TO SEPARATE CIRCUIT, OINSTALL SINGLE DUPLEX & DATA ROUGH -IN CENTERED ON WALL AT 50"AFF FOR TV MONITOR, COORDINATE WITH TV VENDOR AND ARCHITECTURAL ELEVATIONS. OFOR POWER AND LOW VOLTAGE OUTLETS PROVIDE WIREMOLD 4000 INSTALLED CONTINUOUSLY BELOW COUNTER. PROVIDE A DIVIDER WITH A DUPLEX OUTLET INSTALLED AS INDICATE ABOVE DIVIDER. DIVIDE OUTLETS BETWEEN BRANCH CIRCUITS INDICATED. ALL LOW VOLTAGE OUTLETS SHALL BE INSTALLED BELOW DIVIDER. PROVIDE OUTLETS AS INDICATED (DATA QUANTITIES INDICATED). OWNER MAY USE RACEWAY FOR ALL COMMUNICATION CABLES AS REQUIRED. PROVIDE BLANK PLATES OVER ALL UNUSED POSITIONS. TABLE HAS 2 COUNTER HEIGHTS, PROVIDE WM4000 OFFSETS OR CONDUIT CONNECTIONS AS REQUIRED FOR POWER, DATA CABLES MAY BE RUN EXPOSED IF PROTECTED FROM EDGES OF WM. LEAVE COVERS OFF WM UNTIL OWNERS VENDOR HAS INSTALL DATA CABLES AND OUTLETS. PROVIDE BOX/COVERPLATE SUPPORT FOR DATA OUTLETS, OWNERS VENDOR SHALL PROVIDE STANDARD BOX STRAP TYPE OUTLETS AND COVERPLATES FOR HIS DEVICES. ©PROVIDE 1.5" CONDUIT IN WALL TO ABOVE CEILING IF POSSIBLE, OTHERWISE PROVIDE WIREMOLD 4000 INSTALLED CONTINUOUSLY TO ABOVE CEILING AT OR NEAR THIS LOCATION. NO OUTLETS TO BE INSTALLED IN VERTICAL SECTION. CONNECT TO WM IN TABLE AREA LEAVE COVERS OFF WM UNTIL OWNERS VENDOR HAS INSTALL DATA CABLES AND OUTLETS. O MAINTAIN CONTINUITY OF EXISTING BRANCH CIRCUITS SERVING THIS AREA, FED ON SAME EXISTING CIRCUIT AS THE TO BE REWIRED BATHROOMS. VERIFY EXACT LOCATION OF EXISTING CIRCUIT ROUTING AT JOB SITE AND EXTEND AS REQUIRED. EXISTING CIRCUIT ON ORIGINAL PLANS INDICATED ADJACENT PLAN NOTE. ® REWIRE ALL EXISTING OUTLET DEVICES IN THIS ROOM TO NEW SEP PANEL AS INDICATED ADJACENT PLAN NOTE. MAINTAIN SWITCHING AND NIGHT LIGHTS AS PRESENTLY WIRED. Og REWIRE EXISTING DEVICE AS LISTED ADJACENT PLAN NOTE TO NEW SEP PANEL AS INDICATED 10 PROVIDE (1) 3" CONDUIT IN FLOOR TO ABOVE ACCESSIBLE CEILING OF FLOOR BELOW FOR INSTALLATION OF LOW VOLTAGE CABLES. PROVIDE (3) 3" CONDUITS ABOVE ACCESSIBLE CEILING FROM THIS ROOM INTO SUITE FOR INSTALLATION OF LOW VOLTAGE CABLES. PROVIDE 314" THICK FIRE RESISTANT PLYWOOD BACKBOARD FOR OF COMPONENTS (CONTRACTOR MAY USE EXISTING PLYWOOD IF NOT DAMAGED). CLOSE INTERIOR OF ALL CONDUITS WITH FIRE RATED MATERIAL AFTER ALL CABLES ARE INSTALLED. 11 PROVIDE (3)4' CONDUITS THROUGH FIRE WALL, LOCATE ABOVE THE ACCESSIBLE CEILINGS FOR INSTALLATION OF LOW VOLTAGE CABLES. CLOSE INTERIOR OF CONDUITS INSTALLED IN FIRE WALLS WITH FIRE RATED MATERIAL AFTER ALL CABLES ARE INSTALLED. %A WOOLI Architecture I Engine 7635 Interactive Suite 100 Indianapolis, IN 317.299.7500 O�vE%-OPN A Public / F Partners u City Of C India 'Q No. * ARI 9600 STATE I ND A� /"1 9RCHiT' REV VJ C DES, 02/28/2017 r Q L Z 75% PRE[ 0< 04/04/2017 U'^) s VJ W Odd CL `` L.L rV n 00 L Z L CL W L W L Z 0 C Z W W CL � L W (n () REV DATE DES, 02/28/2017 60% OWN 03/13/2017 75% PRE[ 04/04/2017 BID AND I Proj. No.: Date: Sheet Name: POWER & SYSTEM F E=1 1