Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
0159.03.3
SCOPE DOCUMENT THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT. AS SCOPE DOCUMENTS, THE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE PROJECT, THE CONTRACTOR AND SUBCONTRACTORS SHALL FURNISH ALL ITEMS OF WORK REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE PROJECT. GENERAL NOTES A. ALL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. B. ALL FINISHES SHALL COMPLY WITH FLAME SPREAD AND SMOKE DEVELOPMENT STANDARDS AS LISTED IN THE UNIFORM FIRE CODE AND THE UNIFORM BUILDING CODE. C. ALL DIMENSIONS ARE FROM FINISHED FACE OF WALL TO FINISHED FACE OF WALL OR FROM FINISHED FACE OF WALL TO FINISHED FACE OF MASONRY OR FROM FINISHED FACE OF MASONRY TO FINISHED FACE OF MASONRY, UNLESS OTHERWISE NOTED. ALL MASONRY DIMENSIONS ARE NOMINAL. D. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY DESIGNER OR ARCHITECT IMMEDIATELY OF ANY DIMENSIONAL CONFLICTS OR CONFLICTS DUE TO UNKNOWN CONDITIONS. WORK SHALL NOT PROCEED UNTIL CONFLICTS ARE RESOLVED. E. EACH CONTRACTOR SHALL EXAMINE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE, F. REVIEW ALL DRAWINGS (ARCHITECTURAL, PLUMBING, ELECTRICAL, HVAC) CONCERNING SLEEVES, OUTLETS, BOXES, ANCHORS, VENTS, OPENINGS, ETC. THAT MAY BE REQUIRED. EACH RESPECTIVE TRADE IS RESPONSIBLE FOR PROVIDING AND INSTALLING THESE ITEMS. G. ALL SUBCONTRACTORS SHALL PROVIDE SHOP DRAWINGS TO DESIGNER FOR REVIEW ON PRODUCTS OF WORK PRIOR TO FABRICATION AS REQUESTED. H. WHERE NIC = NOT IN CONTRACT, BY OTHERS OR BY OWNER, THE G.C. SHALL COORDINATE AND VERIFY ANY AND ALL SPECIFIC REQUIREMENTS OF FRAMING, BLOCKING, HOOK-UP, SERVICES, UTILITIES, ETC, WITH THE OWNER. I. G.C. TO TAPE, SPACKLE, AND SAND SMOOTH ALL GYPSUM WALL CONSTRUCTION AND PREPARE WALLS TO RECEIVE FINISHES. J. G.C. TO PROVIDE AND INSTALL ANY MISCELLANEOUS BLOCKING AS REQUIRED FOR ANY WALL MOUNTED SHELVING, EQUIPMENT OR ACCESSORIES. K, CONTRACTOR SHALL PROVIDE ALL BARRICADES, DUST PARTITIONS, ETC. AS REQUIRED BY LAW AND AS OTHERWISE REQUIRED. L. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, PALLETS, PACKAGING, UNUSED MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB, M. EACH CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ALL FINISHES SPECIFIED. FINISHES ARE SPECIFIED ONLY. PROPER INSTALLATION METHOD IS TO BE DETERMINED BY CONTRACTOR AND INSTALLER. WALL LEGEND --- i EXISTING WALL CONSTRUCTION ___ EXISTING WALL CONSTRUCTION TO BE REMOVED. NEW PARTIAL HEIGHT PARTITION NEW GLAZED WALL NEW INSULATED WALL APPROVAL FOR CONSTRUCTION The Tenant agrees that these drawings and specifications represent the entire scope of work for the improvements to be provided, The Tenant's signature below represents acceptance of the final design. Any changes to this scope of work initiated by the Tenant will cause changes in the total cost to the Tenant and in the completion dote for the project. r1 p it 1. ALL DOORS TO BE NEW BUILDING STANDARD SOLID CORE WOOD DOORS WITH HOLLOW METAL FRAMES. DOORS TO BE STAINED. FRAMES TO BE PAINTED. ALL DOORS TO HAVE LEVER HANDLES. 2. DOOR #1 TO BE NEVA! ENTRY DOOR AND FRAME. 3. CONTRACTOR TO PROVIDE BLOCKING IN ALL LOCATIONS WHERE SHELVING, CABINETRY OR WORKSURFACES ARE SHOWN. 4. BUILDING STANDARD EXTERIOR WINDOW BLINDS TO BE PROVIDED FOR ALL EXTERIOR WINDOWS. 5. ALL EXPOSED CORNERS TO RECEIVE CLEAR PLASTIC CORNER GUARDS. 6. TOWEL AND SOAP DISPENSERS IN RESTROOMS TO BE PROVIDED BY CONTRACTOR. 7. CONTRACTOR TO PROVIDE CEAR CAULKING AROUND ALL DOOR FRAMES WOOD AND METAL) AFTER DOOR FRAMES HAVE �EEN ADJUSTED AND SET. 8. CONTRACTOR TO PROVIDE LEG SUPPORT FOR ALL COUNTERTOPS NOT SUPPORTED BY BASE CABINETS. 9. CONTRACTOR TO PROVIDE ALL CODE AND ADA REQUIRED FIXTURES AND ACCESSORIES FOR ROOMS 304, 307, 308, AND 311. 10. CONTRACTOR TO PROVIDE STANDARD MIDSIZE SINGLE BOWL STAINLESS STEEL SINK FOR 312 AND 313. 11. ANY FIRE ALARM PULLS EFFECTED BY DEMOLITION TO BE RELOCATED TO NEAREST REMAINING OR NEW WALL. 12. ANY INTERIOR GLAZING REQUIRED TO BE 1/4" LAMINATED SAFETY GLASS. 13. CONTRACTOR TO PROVIDE DOUBLE INSULATION IN WALLS AND EXTRA INSULATION ABOVE CEILING. 14. CONTRACTOR TO PROVIDE ALL MIRRORS AND ACCESSORIES FOR 304, 307, 308, AND 311. 1. NEW WALL CONSTRUCTION TO ALIGN WITH EXISTING COLUMN, WINDOW MULLION, OR EXISTING WALL. 2. CONTRACTOR TO PROVIDE STANDARD MIDSIZE STAINLESS STEEL SINGLE BOWL SINK. 3. CONTRACTOR TO PROVIDE 15"D ADJUSTABLE SHELVING. CONTRACTOR TO DETERMINE BEST ARRANGEMENT AND SUPPORT. 4. CONTRACTOR TO PROVIDE 12"D ADJUSTABLE SHELVING. CONTRACTOR TO DETERMINE BEST ARRANGEMENT AND SUPPORT. 5. CONTRACTOR TO PROVIDE NEW CORRIDOR WALL CONSTRUCTION TO MATCH EXISTING WALL CONSTRUCTION TYPE. 6. CONTRACTOR TO PROVIDE NEW ADA ACCESSIBLE SHOWER/TUB UNIT. 7. LOCATION FOR TECH UNITS (MOBILE) .BY TENANT. 8. LOCATION FOR CEILING MOUNTED TV BY TENANT. CONTRACTOR TO PROVIDE PROPER BLOCKING IN CEILING. T XTRA INSULATION BOVE CEILING X 4 ACOUSTICAL TILE JILDING STANDARD 5/8" METAL STUDS SCOPE OF WORK 1 1 ■ u v Lav I Q (0 >y r\ ■ ■ `� A I L ---I 3 �N 1 RR ■ ■ 1 I 2 "�' RECEPTION 304 �� PATIENT ROOM -' ■ ■ TECH. _ _ 30 _ a ■ 301 j i 4 I 2 c I 31 4 6 J ,-0" 5 O I a, I I w WORK/ ■ COPY I 13 _ _ ■ 312 2 0 o HALL i n " ■ I v 0 302 5'-6" 5-6 ■ JL- HOLD�I H� OLD ii 6 ■. O 10 O v I ;---- , ADA © 4'-0" i ■ I RR o 42 _ Q ■ ■ 311 , I DATIENT ROOM , D ADA ` PATI NT ROOM a ■ ■ ; fi _ PATIENT ROOM iv 309 I RR I W ■ ■ ,,[[�� D `3 t 308 1 RR , 8O 306 ■ ■ 'CJ �,�0 i �\ 307 � � ■ L�1) 0 ■ HOLD 1 *Mmmm■■■■■■■■■■■■mmmmMM■■■MMEMEM■■■■MMMMMMMm■t■■■■■■■■mmm■■1■■ms* 'FLOOR PLAT ' SCALE: 1/8"=1'-0" 0 t 00 -- ---- --- f '�1` I IAMINAI- COUNTER - PL1 W/ BACKSPLASH AND 90 DEGREE RADIUS CORNERS SINGLE BOWL MIDSIZE STAINLESS STEEL SINK r - VINYL BASE - VB1 L - PLASTIC LAMINATE BASE CABINETS - PL2 CONTRACTOR TO DETERMINE BEST ARRANGEMENT. EL EVATION A SCALE: 1 /4"= I'--0" PEDESTAL - PL2 BOX/BOY/FILE ELEVATION B1 SCALE: 1/4"= 1 '-0" PLASTIC LAMINATE UPPER CABINETS - PL2 CONTRACTOR TO DETERMINE O BEST ARRANGEMENT. I J -SINGLE BOWL MIDSIZE N I I I I STAINLESS STEEL SINK PLASTIC LAMINATE I 0 COUNTER - PL1 O� I - W/ BACKSPLASH AND 90 DEGREE co RADIUS CORNERS �- SUPPORT AS REQUIREL O OPEN FOR UNDERCOUNTER ` REFRIGERATOR BY rrl I TENANT I rr i VINYL BASE - VB 1 / P! ASTIC LAMINATE BASE CABINETS - PL2 CONTRACTOR TO DETERMINE BEST ARRANGEMENT. ELEVATION C 1 SCALE :1 /4"=1'-0" PLASTIC LAMINATE UPPER CABINETS - PL2 CONTRACTOR TO DETERMINE BEST ARRANGEMENT, PLASTIC LAMINATE COUNTER - PL1 W/ GROMMETS 4,11) 90 DEGREE RADIUS CORNERS 24" DEEP SUPPORT AS REQUIRED VINYL BASE - V81 BASE CABINETS - PL2 ONTRACTOR TO DETERMINE BEST ARRANGEMENT. ELEVATION C2 SCALE:1 /4"=1'-0" 1 cel•: BE`, { I I I PLASTIC LAMINA - 0 0 I II OPEN _ N PLASTIC LAMINATE PEDESTAL - PL2 BOX/Box/FILE ELEVATION B2 SCALE: 1/4'= V-0" COUNTER - PL' W/ GROMMETS AND 90 DEGREE RADIUS CORNERS 24" DEEP SUPPORT AS REQUIRED VINYL BASE - VB 1 SCALE: 1 /4"=1 ' - 0" r\ DECORATIVE LIGHT , LLJ FIXTURE OVER MIRROR STANDARD ADA FIXTURES SELF EDGE MIRROR J r� PLASTIC LAMINATE UPPER CABINETS - PL2 m SINGLE BOWL CONTRACTOR TO DETERMINE cz DROP IN SINK BEST ARRANGEMENT.6 U N 1/2" MAX DEPTH (7-) y'� •LL O I C W Vco �Q ' 0� PLASTIC LAMINATE r-4 O COUNTER - PL1 PLASTIC LAMINATE �Y W/ APRON, COUNTER - PLI SELF EDGE, AND W/ 90 DEGREEO Li RADIUS CORNERS RADIUS CORNERS N SUPPORT AS REQUIRED 00 x Z Z x x z O < u) O N n ANYL BASE - V81 iv o O m� ®� }\ CD a 4" VINYL BASE I ELEVATION D - ' YP. RESTROOM SINK SCALE: 1 /4"=1 ' - 0" 0- r\ LLJ O ,��r,Netrc��i�lr J r� Q O m W z cz 00 . U N 7D (7-) y'� •LL O I C W Vco �Q ' L O./� r-4 6. �Y cn L 0- r\ LLJ O W Q O m W z cz 00 o cn U N 7D (7-) LL -Q I C t w cn L L L 1 Li rJ OLLi N ;4t- O a' x z O u) L 1 O L V O m� ®� Q CD a pp LJ lG O � 00 07 v �• 0- LLJ W Q O m W z o I _J W o cn U N UJ 0') ?: J LL -Q I CV Q w V) L L L C� Li = OLLi CL O LLJ > z O � U� O L V O m� 0- LLJ Q O m m Z Cp o I z m o U N UJ 0') ?: J Y 1_i•, CV Q U w a SHEET NUMBER` l �r r r, rrrr