Loading...
HomeMy WebLinkAbout17090059 Building Plans 3042 AND DETAILSABBREVIATIONSDEMODEMOVENT ISOMETRICISOMETRICLEGEND, AND SHEET INDEXLEVEL M7-1MECHANICAL SCHEDULESPLUMBINGP0-1PLUMBING SYMBOLS ANDP1-1DPLUMBING UNDERSLAB PLANP2-1DPLUMBING DOMESTIC PLANP1-1PLUMBING UNDERSLAB PLANP1-2PLUMBING ABOVE SLAB PLANP2-1PLUMBING DOMESTIC PLANP5-0PLUMBING DETAILSP6-1PLUMBING SANITARY ANDP6-2PLUMBING DOMESTICP7-0PLUMBING SCHEDULESELECTRICALE001ABBREVIATIONS, G.P.N.,E201LIGHTING PLAN - MAIN LEVELE202LIGHTING PLAN - UPPERE301POWER PLAN - MAIN LEVELE302POWER PLAN - UPPER LEVELE602ELECTRICAL SCHEDULES VECINITY MAP PLANSRESTROOM PLANSPLANABBREVIATIONSDEMO HVAC PLANHVAC PLANDEMO HVAC PLANHVAC PLANPIPING PLAN DRAWING LIST GENERALG0-1CODE PLANS/ OVERALLDEMOLITIOND1-1MAIN LEVEL DEMO PLAND1-2UPPER LEVEL DEMO PLAND2-1MAIN LEVEL RCP DEMOD2-2UPPER LEVEL RCP DEMOARCHITECTUREA1-1MAIN LEVEL PLANA1-2UPPER LEVEL PLANA2-1MAIN LEVEL RCPA2-2UPPER LEVEL RCPA4-1EXTERIOR ELEVATIONSA4-2EXTERIOR ELEVATIONSA5-1BUILDING SECTIONSA8-1DOOR/FRAME SCHEDULEA9-1ENLARGED FLOOR PLANS/INTERIORI0-1MAIN LEVEL FURNITURE PLANI0-2UPPER LEVEL FURNITUREI1-1MAIN LEVEL FINISH PLANI1-2UPPER LEVEL FINISH PLANI2-1INTERIOR ELEVATIONSI2-2INTERIOR ELEVATIONSMECHANICALM0-1MECHANICAL SYMBOLS ANDM2-1DMECHANICAL MAIN LEVELM2-1MECHANICAL MAIN LEVELM2-2DMECHANICAL UPPER LEVELM2-2MECHANICAL UPPER LEVELM3-1MECHANICAL MAIN LEVEL 3042 SPACES = TOTAL OF 222 MAX CODE REVIEW PROVIDE MS @ FRAMEDOPENING ALL SIDES TYP. 6,000 S.F. ORIGINALLY BUILT AS FARM BUILDING & REMODELEDIN 1985 TO BE MULTIFUNCTION MEETING ROOMS. THERE WASAN INTERIOR REMODEL CHANGING OCCUPANCY TO A-3CHURCH ASSEMBLY. THIS IS A TWO STORY BUILDING. EQ = 2'- 2 3/4" NORTHVIEW CHRISTIAN CHURCH - ADULT CLASSROOM PROJECT2014 INDIANA BUILDING CODE (IBC)IBC INTERNATIONAL BUILDING CODE 2012 - (BASE CODE)2012 INTERNATIONAL MECHANIC CODE2006 INTERNATIONAL PLUMBING CODE2008 NFPA 70ASHRAE 90.1 20072012 INTERNATIONAL FIRE CODE2010 VERSION AMERICANS WITH DISABILITY ACT2014 IBC INTERNATIONAL BUILDING CODE, CHAPT 11 - ACCESSIBILITY6,000 S.F. INTERIOR REMODEL OF FINISHES AND MEP. THERENOVATION ALSO INCLUDES SUBDIVIDING SPACE FORMEETING ROOMS.ALTERATIONS ARE PERMITTED TO AN EXISTING BUILDINGWITHOUT REQUIRING THE ENTIRE EXISTING BUILDING ORPORTIONS OF THE EXISTING BUILDING UNAFFECTED BYTHE PROPOSED SCOPE OF RENOVATION TO BE BROUGHTINTO COMPLIANCE WITH CURRENT CODES \[RULE 4,SECTION 12, GAR - 107, IBC\] THE PROJECT DOES NOTINCLUDE A CHANGE OF OCCUPANCY PER RULE 4, SECTION12 (B) - THE AREA WILL REMAIN AN A-3 OCCUPANCY.GATHERING AND COLLABORATION A-3 OCCUPACY \[303.4\]TYPE IIB CONSTRUCTION EXISTING - NO CHANGESPROPOSED TO BUILDING ELEMENTS REGULATED BY TABLE 601ALL EXISTING VERTICAL OPENINGS TO BE MAINTAINED INEXISTING CONFIGURATIONNONE APPLICABLE TO THIS PROJECT \[TABLE 509\]EXISTING MEANS OF EGRESS, INCLUDING EXTERIOR EXITSWILL BE MAINTAINED IN EXISTING CONFIGURATIONTHE BUILDING IS NOT SPRINKLEREDTHE PROJECT SCOPE INCLUDES UPGRADE OF FIRE ALARMSYSTEMALTERATIONS TO THE BUILDING INCLUDE SIGNIFICANTUPGRADE TO ELECTRICAL REQUIRING A COM CHECK.BECAUSE THERE IS NO CHANGE IN OCCUPANCY,ARCHITECTURAL AND MECHANICAL COM CHECKS ARE NOTREQUIRED. ALTERATIONS TO BOTH ARCHITECTURE ANDMECHANICAL ARE SUCH THAT THE BUILDING WILL BE MOREENERGY EFFICIENT. ADDED VESTIBULE, INTERIOR INSULATION,AND MECHANICAL UPGRADES ARE PROVIDED AS PART OF THISBUILDING REMODEL. EQ = 9" EQ = 11 3/4" ELEV. PLAN EQ = 3'-10 5/8" EQ = 5'-0" EXIT1 HOUR RATED ENCLOSUREFIRE EXTINGUISHER CABINET. REFER TO DETAIL 3/G0-1NEW WALLS 1/8" = 1'-0" 1 HR FEC CODE PLAN NOTES(FEC) TYP. FIRE CABINET DETAIL SCALE: SEMI-RECESSED F.E. CABINET DEPTH POTTER-ROEMER 7000 SERIES OR EQ. 3 MIN. OPENING FINISHED WALL 11 11 11 22 MALEFEMALE LIST OF ARCH. ALTERNATES 1. REMOVE PLUMBING LAV. AND WATERCLOSET # TO CODE MIN. REDUCING STALLPARTITIONS AND R.R. FIXTURESACCORDINGLY.2. PRICE TO CHANGE FROM ALUMINUMEXTERIOR WINDOWS TO RESIDENTIAL TYPE\[AF-3, AF-6, AF-4\]3. RE-USE COILING DOOR AND COUNTERSIN NEW LOCATION.4. REMOVE FROM SCOPE PAINTING OFEXPOSED CEILING WHERE EXISTING OPENCEILING IS CALLED TO BE RE-PAINTED.5. REMOVE VESTIBULE DETAIL 3/A1-2COMPLETELY, NOTE 23 AND 26 ON A1-2.SHOP DRAWINGS NEEDED*DOORS AND DOOR HARDWARE*FRAMES, WINDOWS AND DOORS*R.R. PARTITIONS*FLOORING AND BASE MATERIAL*PAINT DRAW DOWN*GLAZING 12 13 MALEFEMALE NTS OCCUPANCY CHART SCALE: *A-3 OCCUPANCY** BASED ON CLASSROOM AREA OCCUPANCY LOAD (NON-FIXED SEATING)** BASED ON TABLE 2902.1 IN IBC 4 53' - 4" 111 108 270 SF/20OCC: 13412 SF/20OCC: 20 81 SF/300OCC: 1 108B MEETING ROOM #4 MEETING ROOM #3 MECH/STOR 26' - 1" MAIN LEVEL FLOOR PLAN 107 112 154 SF/20OCC: 7 . 186 SF/20OCC: 9 S T I X E W T B D MEETING ROOM #2E R I MEETING ROOM #5 U Q . E E R C FEC S IN A E T C S I N AD T D S IE DD I "V 6 -O ' R 1 2P " . 1 " 11 - 1' - 5 ' 3 2 4 S CONCRETESTOOP 109I E 839 SF/15OCC: 56C N 106AA T 174 SF/20OCC: 8 S I D L A N O GATHERING ROOMG 35' - 3" A I D MEETING ROOM #1 20' - 0" OPEN TO FLOORBELOW DN 201 STOR39 SF/300OCC: 1 UP FEC DN 200 83 SF 105 VESTIBULE 180 SF/300OCC: 1 136 SF MECHANICAL/STORAGE REF. 203 25' - 2" 801 SF/20OCC: 40 114 861 SF/20OCC: 43 OPEN TO FLOOR BELOW 26' - 3" MEETING ROOM #8 MEETING ROOM #6 104 DN 154 SF WOMENS RR FEC 202 108 SF/300OCC: 1 MECHANICAL B102 89 SF OPEN TO FLOOR BELOW CORRIDOR 103 144 SF MENS RR 116 512 SF/20OCC: 25 19' - 11" MEETING RM #7 1/8" = 1'-0" 1/8" = 1'-0" 101 100 51 SF STAND 58SF/300OCC: 1 VESTIBULE CONCESSION 02 - UPPER LEVEL CODE PLAN SCALE:01 -MAIN LEVEL CODE PLAN SCALE: 21 CONCRETESTOOP 49' - 7" NN PLAN NORTHPLAN NORTH 3042 D# ABLISH COSTS OF DEMOLITION DURING IBILITY TO BECOME FAMILIAR WITH ALL OR IN DETERMINING WHICH ITEMS ARE TO OOSE FURNITURE ITEMS TO BE REUSED. NCIES FOUND IN DIMENSIONS SHOWN TO WHEN REMOVING TO NOT DAMAGE. DRAWINGS FOR ADDITIONAL DEMOLITION UPPER LEVEL PLAN. FLOORING STAIRS ING COMPLETELY. PATCH AND REPAIROOR DEMO TO ACCESS LOWER LEVEL. RETY, INCLUDING UPPER CABINETS CONSTRUCTION. AFTER SUBSTANTIAL THE OWNER WILL HAVE 1ST RIGHT OF DISPOSITION DASHED LINES DENOTES WALLS / DOORSTO BE DEMOLISHED IN ITS ENTIRIETY.WALLS TO REMAINHATCH DEFINES WORK AREA NOT INSCOPE WINDOW. INFILL PORTION OF OPENING WITH CONSTRUCTION MATCHINGSURROUNDING WALL.DOOR.INSULATION. REFER TO DETAILOPENING FOR INSTALLATION OF NEW WINDOW.CONSTRUCTION OF WALL.NEW SLIDING BARN DOOR.COORDINATE WITH DOOR SCHEDULE AND FIRST FLOOR PLAN PRIOR TODEMO.INSTALLATION OF NEW DOOR AND WINDOW OR INFILL PER NEW PLAN.SURFACES SCHEDULED TO REMAIN.WALL AND FLOOR AS NEEDED.PLANS FOR ADDITIONAL INFO.PREP FOR REPLACEMENT WINDOW. OWNER/ARCH TO VERIFY IF ROLLINGDOOR CAN BE RE-USED. CAREFULL FLOOR FOR NEW FINISH.ACCESS. PATCH AND REPAIR AS NEEDED. PROVIDE NEW DOORHARDWARE FOR DOOR. REFER TO DOOR SCHEDULE AND SPECS FORADDITIONAL INFORMATION.BEHIND.RE-USED. CAREFULL WHEN REMOVING TO NOT DAMAGE.LOCATION.REMOVED COMPLETELY. COLUMNS AND HORIZONTAL BRACING TOREMAIN. COORDINATE WITH ARCH. PRIOR TO DEMO WORK. GENERAL DEMO NOTES A -- DASHED LINES INDICATE ITEMS TO BE REMOVED SEE OTHER DRAWINGS FORADDITIONAL ITEMS TO BE REMOVED DUE TO NEW CONSTRUCTION. THE PLAN NOTESON THIS SHEET ARE TO AID THE CONTRACTBE REMOVED FOR THE CONTRACTOR TO ESTBIDDING. IT IS THE CONTRACTORS RESPONSNEW CONSTRUCTION AND ANY ADDITIONAL ITEMS TO BE DEMOLISHED TO ACHIEVETHE NEW DESIGN: ANY & ALL FURNISHINGS, EQUIPMENT, FIXTURES, AND/OR DEVICESTO BE REMOVED BY DEMOLITION: OF ITEMS REMOVED BY CONTRACTOR B -- COORDINATE LIGHT FIXTURE & DOOR DEMOLITION W/ OWNER. ANY ITEMSREMOVED FOR THIS PROJECT TO GO TO OWNER. OWNER TO PROVIDE LOCATIONFOR STORAGEC -- ITEMS THAT ARE TO REMAIN THAT ARE DAMAGED DUE TO DEMOLITION OR NEWCONSTRUCTION ARE TO BE REPAIRED OR REPLACED TO OWNER'S SATISFACTIOND -- AT THE END OF DEMOLITION, THE CONTRACTOR IS TO VERIFY GIVEN DIMENSIONSAND NOTIFY THE ARCHITECT OF DISCREPAEXISTING WALLS & COLUMNSE -- COORDINATE WITH EXISTING MEP EXTENT & REQUIREMENTSF -- REFER TO ROOM FINISH SCHEDULE FOR FINISH ITEMS TO BE REMOVED SUCH ASWALL COVERINGS & FLOOR COVERINGS. IF THE ROOM FINISH SCHEDULE CALLS FORNEW COVERINGS THEN THE EXISTING IS TO BE REMOVED ENTIRELY AND THE WALL ISTO BE PREPARED FOR NEW FINISHESG -- ALL ABANDONED ELECTRICAL OUTLETS TO BE REMOVED IN THEIR ENTIRETY(INCLUDING DEVICES, CONDUIT, WIRING, ETC.) PATCH WALLS AS REQUIRED FORNEW FINISHES.H -- IT WILL BE THE RESPONSIBILITY OF OWNER TO REMOVE EXISTING LOOSEFURNITURE, ARTWORK, PRIOR TO COMPLETION, OWNER TO RELOCATE ANY LCONTRACTOR TO GIVE 1 WEEK NOTICE PRIOR TO BEGIN OF CONSTRUCTION ANDCOMPLETIONI -- IN LOCATIONS WHERE WALLS ARE REMOVED ON EXTERIOR OR INTERIOR,CONTRACTOR TO PROVIDE TEMPORARY BARRIERJ -- DEMOLITION CONTRACTOR TO PROVIDE DUMPSTER AND ANY TEMPORARYELECTRICITY/ POWER NEEDED TO COMPLETE WORKK -- REMOVE ALL EXISTING LIGHT FIXTURES, ANY TO REMAIN WILL BE CALLED OUTSPECIFICALLY ON THE PLANS.L -- DIGITAL COPIES OF EXISTING DRAWINGS ARE AVAILABLE- CONTACTARCHITECT FOR ACCESS TO DRAWINGS.M -- THE OWNER WILL PAY FOR TEMPORARY UTILITY COSTS INCURRED BY THECONTRACTOR SINCE BUILDING IS EXISTINGN -- PATCH ALL EXISTING WALLS WHERE SWITCHES, OUTLETS, DATA BOXES,SURFACE MOUNTED SOAP DISPENSERS, ETC ARE REMOVED.O -- RE-USE ANY EXISTING DOORS AND FRAMES WHERE POSSIBLE.P -- ALL HANGING LIGHT FIXTURES INTERIOR AND EXTERIOR TO BE REMOVEDCOMPLETELYQ -- REMOVE ALL EXISTING BLINDS ABOVE WINDOWS UNLESS NOTED OTHERWISE DEMO PLAN NOTES D2REMOVE DOOR AND REFRAME OPENING FOR INSTALLATION OF NEWD3REMOVE WINDOW AND REFRAME OPENING FOR INSTALLATION OF NEWD4REMOVE OVERHEAD DOOR AND FILL OPENING WITH METAL STUDS ANDD5REMOVE RESTROOM FIXTURES AND EQUIPMENTD6REMOVE R.R. PARTITIONSD7REMOVE EXISTING WINDOWS AND FRAMES COMPLETELY. PREPARED8REMOVE EXSITING DOOR COMPLETE. INFILL OPENING WITH MATCHINGD9REMOVE DOOR AND FRAME. PREPARE OPENING FOR INSTALLATION OFD10CUT OPENING IN WALL FOR INSTALLATION OF NEW DOOR/WINDOW.D11REMOVE DOOR AND FRAME COMPLETE. PREPARE OPENING FORD12REMOVE CASEWORK IN ITS ENTID13REMOVE EXISTING INTERIOR WALL IN ENTIRETY. PATCH ANY EXISTINGD14EXISTING DUCTOWKR TO REMAIND15REMOVE WOOD STAIRS AND RAILD16REMOVE INTERIOR WINDOW TO BE INFILLED PER NEW PLAN.D17REMOVE & REPLACE EXISTING WATER COOLER. REFER TO PLUMBINGD18REMOVE EXISTING SHUTTER COMPLETELY, PATCH ALL ADJACENT TOD20REMOVE ALL EXISTING FLOORING AND BASE DOWN TO SUBFLOOR. PREPD21PROVIDE ACCESS FOR CONDUIT AND WIRING FOR NEW ELECTRICAL CARDD22COORDINATE WITH MECH FOR FLD23REMOVE EXISTING MENU DISPLAY CASES. PATCH/REPAIR WOOD FINISHD24REMOVE EXISTING SIGNAGE. MEET WITH OWNER FOR POSSIBLE REUSE.D25REMOVE COUNTERTOP. OWNER/ARCH TO VERIFY IF COUNTERTOP CAN BED26REMOVE/RELOCATE FIRE EXTINGUISHER. REFER TO CODE PLAN FOR NEWD27REMOVE FINISH LAYER DOWN TO STUD ON GARAGE ROOM SIDE.D28UPPER LOFT TO BE REMOVED ON 2 A5-1 AE BCD 53' - 4" 13' - 11" D13 7' - 11" 7' - 11" STORAGE D13 D7 D23 25' - 1" 01 D13 1/4" = 1'-0" MAIN LEVEL DEMO PLAN SCALE: 16' - 10" 1 D7 N PLAN NORTH D13 02 8' - 1" D7 OPEN SPACE D13 16' - 8" D11 20' - 6" D7 EDGE OF SOFFIT 11" D7 D8 UP D10 03 D11 3' - 0 1/2" D10 9' - 4" D12 D13 MECHANICALROOM 11' - 11" D7 D12 D12 D17 1 A5-1 18' - 9" D5 FUME HOODLOUNGE AREA #1 D6 04 25' - 4" KITCHEN 1' - 4 1/2" WOMEN'SRR D13 D5 D12 D10 8' - 8" D13 D7 D13 11' - 10" D6 D5 6' - 5" 4' - 8" D8 D24 D26 REF. MEN'SRR FEC D11D13 05 UP D16D16 D27 D7 D15 D14 D2 D8 19' - 11" D13 GARAGELOUNGE AREA #2 D7 D25 D12 D4 D10D10 1' - 1" 06 13' - 7 1/2" D7 D23D23D24 D18D25 2 A1-1 3042 D# ER. REFER TO CODE PLAN FOR NEW ABLISH COSTS OF DEMOLITION DURING WHEN REMOVING TO NOT DAMAGE. OR IN DETERMINING WHICH ITEMS ARE TO OOSE FURNITURE ITEMS TO BE REUSED. NCIES FOUND IN DIMENSIONS SHOWN TO UPPER LEVEL PLAN. FLOORING STAIRS ING COMPLETELY. PATCH AND REPAIROOR DEMO TO ACCESS LOWER LEVEL. RETY, INCLUDING UPPER CABINETS ARY UTILITY COSTS INCURRED BY THE E SWITCHES, OUTLETS, DATA BOXES, DRAWINGS FOR ADDITIONAL DEMOLITION CONSTRUCTION. AFTER SUBSTANTIAL THE OWNER WILL HAVE 1ST RIGHT OF DISPOSITION XTURES AND EQUIPMENT DASHED LINES DENOTES WALLS / DOORSTO BE DEMOLISHED IN ITS ENTIRIETY.WALLS TO REMAINHATCH DEFINES WORK AREA NOT INSCOPE WINDOW. INFILL PORTION OF OPENING WITH CONSTRUCTION MATCHINGSURROUNDING WALL.DOOR.INSULATION. REFER TO DETAILOPENING FOR INSTALLATION OF NEW WINDOW.CONSTRUCTION OF WALL.NEW SLIDING BARN DOOR.COORDINATE WITH DOOR SCHEDULE AND FIRST FLOOR PLAN PRIOR TODEMO.INSTALLATION OF NEW DOOR AND WINDOW OR INFILL PER NEW PLAN.SURFACES SCHEDULED TO REMAIN.WALL AND FLOOR AS NEEDED.PLANS FOR ADDITIONAL INFO.PREP FOR REPLACEMENT WINDOW. OWNER/ARCH TO VERIFY IF ROLLINGDOOR CAN BE RE-USED. CAREFULL FLOOR FOR NEW FINISH.ACCESS. PATCH AND REPAIR AS NEEDED. PROVIDE NEW DOORHARDWARE FOR DOOR. REFER TO DOOR SCHEDULE AND SPECS FORADDITIONAL INFORMATION.BEHIND.RE-USED. CAREFULL WHEN REMOVING TO NOT DAMAGE.LOCATION.REMOVED COMPLETELY. COLUMNS AND HORIZONTAL BRACING TOREMAIN. COORDINATE WITH ARCH. PRIOR TO DEMO WORK. DEMO PLAN NOTES GENERAL DEMO NOTES A -- DASHED LINES INDICATE ITEMS TO BE REMOVED SEE OTHER DRAWINGS FORADDITIONAL ITEMS TO BE REMOVED DUE TO NEW CONSTRUCTION. THE PLAN NOTESON THIS SHEET ARE TO AID THE CONTRACTBE REMOVED FOR THE CONTRACTOR TO ESTBIDDING. IT IS THE CONTRACTORS RESPONSIBILITY TO BECOME FAMILIAR WITH ALLNEW CONSTRUCTION AND ANY ADDITIONAL ITEMS TO BE DEMOLISHED TO ACHIEVETHE NEW DESIGN: ANY & ALL FURNISHINGS, EQUIPMENT, FIXTURES, AND/OR DEVICESTO BE REMOVED BY DEMOLITION: OF ITEMS REMOVED BY CONTRACTOR B -- COORDINATE LIGHT FIXTURE & DOOR DEMOLITION W/ OWNER. ANY ITEMSREMOVED FOR THIS PROJECT TO GO TO OWNER. OWNER TO PROVIDE LOCATIONFOR STORAGEC -- ITEMS THAT ARE TO REMAIN THAT ARE DAMAGED DUE TO DEMOLITION OR NEWCONSTRUCTION ARE TO BE REPAIRED OR REPLACED TO OWNER'S SATISFACTIOND -- AT THE END OF DEMOLITION, THE CONTRACTOR IS TO VERIFY GIVEN DIMENSIONSAND NOTIFY THE ARCHITECT OF DISCREPAEXISTING WALLS & COLUMNSE -- COORDINATE WITH EXISTING MEP EXTENT & REQUIREMENTSF -- REFER TO ROOM FINISH SCHEDULE FOR FINISH ITEMS TO BE REMOVED SUCH ASWALL COVERINGS & FLOOR COVERINGS. IF THE ROOM FINISH SCHEDULE CALLS FORNEW COVERINGS THEN THE EXISTING IS TO BE REMOVED ENTIRELY AND THE WALL ISTO BE PREPARED FOR NEW FINISHESG -- ALL ABANDONED ELECTRICAL OUTLETS TO BE REMOVED IN THEIR ENTIRETY(INCLUDING DEVICES, CONDUIT, WIRING, ETC.) PATCH WALLS AS REQUIRED FORNEW FINISHES.H -- IT WILL BE THE RESPONSIBILITY OF OWNER TO REMOVE EXISTING LOOSEFURNITURE, ARTWORK, PRIOR TO COMPLETION, OWNER TO RELOCATE ANY LCONTRACTOR TO GIVE 1 WEEK NOTICE PRIOR TO BEGIN OF CONSTRUCTION ANDCOMPLETIONI -- IN LOCATIONS WHERE WALLS ARE REMOVED ON EXTERIOR OR INTERIOR,CONTRACTOR TO PROVIDE TEMPORARY BARRIERJ -- DEMOLITION CONTRACTOR TO PROVIDE DUMPSTER AND ANY TEMPORARYELECTRICITY/ POWER NEEDED TO COMPLETE WORKK -- REMOVE ALL EXISTING LIGHT FIXTURES, ANY TO REMAIN WILL BE CALLED OUTSPECIFICALLY ON THE PLANS.L -- DIGITAL COPIES OF EXISTING DRAWINGS ARE AVAILABLE- CONTACTARCHITECT FOR ACCESS TO DRAWINGS.M -- THE OWNER WILL PAY FOR TEMPORCONTRACTOR SINCE BUILDING IS EXISTINGN -- PATCH ALL EXISTING WALLS WHERSURFACE MOUNTED SOAP DISPENSERS, ETC ARE REMOVED.O -- RE-USE ANY EXISTING DOORS AND FRAMES WHERE POSSIBLE.P -- ALL HANGING LIGHT FIXTURES INTERIOR AND EXTERIOR TO BE REMOVEDCOMPLETELYQ -- REMOVE ALL EXISTING BLINDS ABOVE WINDOWS UNLESS NOTED OTHERWISE D2REMOVE DOOR AND REFRAME OPENING FOR INSTALLATION OF NEWD3REMOVE WINDOW AND REFRAME OPENING FOR INSTALLATION OF NEWD4REMOVE OVERHEAD DOOR AND FILL OPENING WITH METAL STUDS ANDD5REMOVE RESTROOM FID6REMOVE R.R. PARTITIONSD7REMOVE EXISTING WINDOWS AND FRAMES COMPLETELY. PREPARED8REMOVE EXSITING DOOR COMPLETE. INFILL OPENING WITH MATCHINGD9REMOVE DOOR AND FRAME. PREPARE OPENING FOR INSTALLATION OFD10CUT OPENING IN WALL FOR INSTALLATION OF NEW DOOR/WINDOW.D11REMOVE DOOR AND FRAME COMPLETE. PREPARE OPENING FORD12REMOVE CASEWORK IN ITS ENTID13REMOVE EXISTING INTERIOR WALL IN ENTIRETY. PATCH ANY EXISTINGD14EXISTING DUCTOWKR TO REMAIND15REMOVE WOOD STAIRS AND RAILD16REMOVE INTERIOR WINDOW TO BE INFILLED PER NEW PLAN.D17REMOVE & REPLACE EXISTING WATER COOLER. REFER TO PLUMBINGD18REMOVE EXISTING SHUTTER COMPLETELY, PATCH ALL ADJACENT TOD20REMOVE ALL EXISTING FLOORING AND BASE DOWN TO SUBFLOOR. PREPD21PROVIDE ACCESS FOR CONDUIT AND WIRING FOR NEW ELECTRICAL CARDD22COORDINATE WITH MECH FOR FLD23REMOVE EXISTING MENU DISPLAY CASES. PATCH/REPAIR WOOD FINISHD24REMOVE EXISTING SIGNAGE. MEET WITH OWNER FOR POSSIBLE REUSE.D25REMOVE COUNTERTOP. OWNER/ARCH TO VERIFY IF COUNTERTOP CAN BED26REMOVE/RELOCATE FIRE EXTINGUISHD27REMOVE FINISH LAYER DOWN TO STUD ON GARAGE ROOM SIDE.D28UPPER LOFT TO BE REMOVED ON 2 A5-1 E ABCD MAIN LEVEL FLOOR PLAN 01 35' - 3" 02 12' - 4"9' - 3"13' - 9" D22OPEN TO FLOOR BELOW 3' - 0"8"3' - 0"1' - 3" DN 03 D21 D10D10 DN D21 1 A5-1 D28D28 21' - 4" D20D20 04 25' - 2" D22 OPEN TO FLOOR BELOW 2 D15 A1-2 D28D28 DN 05 D8 D15 OPEN TO FLOOR BELOW D22 1/4" = 1'-0" UPPER LEVEL DEMO PLAN SCALE: 1 06 N PLAN NORTH 3042 DC# IBILITY TO BECOME FAMILIAR WITH ALL OR IN DETERMINING WHICH ITEMS ARE TO NCIES FOUND IN DIMENSIONS SHOWN TO REPLACED TO OWNER'S SATISFACTION PRIOR TO BEGIN OF CONSTRUCTION AND E SWITCHES, OUTLETS, DATA BOXES, OVIDE DUMPSTER AND ANY TEMPORARY CONSTRUCTION. AFTER SUBSTANTIAL THE OWNER WILL HAVE 1ST RIGHT OF DISPOSITION DASHED LINES DENOTES WALLS / DOORSTO BE DEMOLISHED IN ITS ENTIRIETY.WALLS TO REMAINHATCH DEFINES WORK AREA NOT INSCOPE 2x2 RETURN AIR VENT 2X2 FLUORESCENT FIXTURE2x4 FLUORESCENT FIXTURE W/ACRYLIC LENSE2x2 LIGHT / FANDOWN LIGHT, RECESSED IN DRYWALLPLASTER OR ACOUSTICAL TILESINGLE POLE SWITCHSPEAKER2x2 SUPPLY DIFFUSEREXIT SIGNSMOKE DETECTORACT - ACOUSTIC CEILING 2'X2' GRID& TILEGYP - GYPBOARDEXP - EXPOSED TO STRUCTURE ANDFLOOR / ROOF ABOVE - BOTTOM OF EXPOSEDSTRUCTURE- BOTTOM OF SLOPE- TOP OF SLOPE- CEILING HEIGHT FOR CODE \[7'-0" AFF ALLOWABLE MIN\].UNUSED WIRING.FLOOR ABOVE. REMOVE ANY ABANDONED WIRES, CONDUIT, OR PIPING.NEW WINDOW.NEEDED.INFORMATION. SD S B.O.E.B.O.S.T.O.S.C.H. DEMO CEILING PLAN NOTES DC1HATCHED AREA INDICATES EXPOSED BEAMS WITHIN THE BARN TO REMAINDC2DRYWALL BULKHEAD FOR DUCTWORK TO BE REMOVED COMPLETELY, TOO LOWDC3EXISTING SLOPED CEILING TO REMAIN, PREP FOR NEW PAINT BY REMOVING ANYDC4EXISTING CEILING TO REMAINDC5DEMO HARD CEILING INCLUDING LIGHTS IN PREP FOR EXPOSED CEILING TODC6DEMO FOR NEW INTERIOR WINDOW. REFER TO WINDOW ELEVATIONS FOR SIZE OFDC7EXISTING 8'-0" WALLS TO BE DEMOLISHED IN IT'S ENTIRETY.DC8STAIRCASE AND WALL TO BE DEMOLISHED. PATCH AND REPAIR WALL ASDC9EXISTING TRACK LIGHT TO REMAIN.DC10EXISTING PENDANT LIGHT TO REMAIN.DC11DEMOLISH EXISTING LIGHTS. REFER TO ELECTRICAL FOR ADDITIONALDC12LINE OF DUCT WORK AT CELING LINE.DC13REMOVE EXISTING PLEXIGLASS SHEET. PREP FOR NEW WALL INFILL. GENERAL DEMO NOTES A -- DASHED LINES INDICATE ITEMS TO BE REMOVED SEE OTHER DRAWINGS FORADDITIONAL ITEMS TO BE REMOVED DUE TO NEW CONSTRUCTION. THE PLAN NOTESON THIS SHEET ARE TO AID THE CONTRACTBE REMOVED FOR THE CONTRACTOR TO ESTABLISH COSTS OF DEMOLITION DURINGBIDDING. IT IS THE CONTRACTORS RESPONSNEW CONSTRUCTION AND ANY ADDITIONAL ITEMS TO BE DEMOLISHED TO ACHIEVETHE NEW DESIGN: ANY & ALL FURNISHINGS, EQUIPMENT, FIXTURES, AND/OR DEVICESTO BE REMOVED BY DEMOLITION: OF ITEMS REMOVED BY CONTRACTOR B -- COORDINATE LIGHT FIXTURE & DOOR DEMOLITION W/ OWNER. ANY ITEMSREMOVED FOR THIS PROJECT TO GO TO OWNER. OWNER TO PROVIDE LOCATIONFOR STORAGEC -- ITEMS THAT ARE TO REMAIN THAT ARE DAMAGED DUE TO DEMOLITION OR NEWCONSTRUCTION ARE TO BE REPAIRED OR D -- AT THE END OF DEMOLITION, THE CONTRACTOR IS TO VERIFY GIVEN DIMENSIONSAND NOTIFY THE ARCHITECT OF DISCREPAEXISTING WALLS & COLUMNSE -- COORDINATE WITH EXISTING MEP DRAWINGS FOR ADDITIONAL DEMOLITIONEXTENT & REQUIREMENTSF -- REFER TO ROOM FINISH SCHEDULE FOR FINISH ITEMS TO BE REMOVED SUCH ASWALL COVERINGS & FLOOR COVERINGS. IF THE ROOM FINISH SCHEDULE CALLS FORNEW COVERINGS THEN THE EXISTING IS TO BE REMOVED ENTIRELY AND THE WALL ISTO BE PREPARED FOR NEW FINISHESG -- ALL ABANDONED ELECTRICAL OUTLETS TO BE REMOVED IN THEIR ENTIRETY(INCLUDING DEVICES, CONDUIT, WIRING, ETC.) PATCH WALLS AS REQUIRED FORNEW FINISHES.H -- IT WILL BE THE RESPONSIBILITY OF OWNER TO REMOVE EXISTING LOOSEFURNITURE, ARTWORK, PRIOR TO COMPLETION, OWNER TO RELOCATE ANY LOOSE FURNITURE ITEMS TO BE REUSED.CONTRACTOR TO GIVE 1 WEEK NOTICE COMPLETIONI -- IN LOCATIONS WHERE WALLS ARE REMOVED ON EXTERIOR OR INTERIOR,CONTRACTOR TO PROVIDE TEMPORARY BARRIERJ -- DEMOLITION CONTRACTOR TO PRELECTRICITY/ POWER NEEDED TO COMPLETE WORKK -- REMOVE ALL EXISTING LIGHT FIXTURES, ANY TO REMAIN WILL BE CALLED OUTSPECIFICALLY ON THE PLANS.L -- DIGITAL COPIES OF EXISTING DRAWINGS ARE AVAILABLE- CONTACTARCHITECT FOR ACCESS TO DRAWINGS.M -- THE OWNER WILL PAY FOR TEMPORARY UTILITY COSTS INCURRED BY THECONTRACTOR SINCE BUILDING IS EXISTINGN -- PATCH ALL EXISTING WALLS WHERSURFACE MOUNTED SOAP DISPENSERS, ETC ARE REMOVED.O -- RE-USE ANY EXISTING DOORS AND FRAMES WHERE POSSIBLE.P -- ALL HANGING LIGHT FIXTURES INTERIOR AND EXTERIOR TO BE REMOVEDCOMPLETELYQ -- REMOVE ALL EXISTING BLINDS ABOVE WINDOWS UNLESS NOTED OTHERWISE REFLECTED CEILING PLAN LEGEND ABE CD B.O.S. DC3DC3 DC11 DC11 DC11 9' - 10" DC7 DC11 SLOPE UP DC3DC3 B.O.E. 12' - 0" DC1DC1 01 1/4" = 1'-0" MAIN LEVEL RCP DEMO SCALE: DC11 DC11DC11DC11 1 T.O.S. B.O.E. 8' - 0" 18' - 2" N DC7 PLAN NORTH 02 B.O.S. 9' - 5" DC11 DC11DC11 DC3DC3 DC3DC3 DC3DC3 SLOPE UP T.O.S. UPB.O.S. SLOPE 16' - 0" 11' - 8" 03 DC2 14' - 2" DC4DC4 DC2 DC10 DC10 DC2 DC1 DC5DC5 DC5DC5 7' - 4" DC3DC3 C.H. 7' - 0" B.O.S. 04 DC5DC5 DC2 SLOPE UP DC1 10' - 5" C.H. T.O.S. DC11 DC5DC5 C.H. 7' - 0" 6' - 3" 16' - 0" C.H. 7' - 0" 14' - 2" C.H. 7' - 2" DC10 C.H. C.H. 7' - 0" 7' - 0" 6' - 5" 6' - 3" C.H.C.H. DC2 DC5DC5 6' - 5" DC11 7' - 0" DC10 05 T.O.S. B.O.S. DC8 14' - 2" 11' - 8" C.H. 16' - 0" DC10 8' - 0" B.O.E. DC3DC3 7' - 3" 9' - 6" DC1 DC12 DC9 T.O.S. 13' - 0" DC1 DC1DC3DC3 B.O.S. B.O.S. DC3DC3 9' - 5" 9' - 5" SLOPE UPSLOPE UP DC10 06 3042 DC# ABLISH COSTS OF DEMOLITION DURING OR IN DETERMINING WHICH ITEMS ARE TO NCIES FOUND IN DIMENSIONS SHOWN TO E SWITCHES, OUTLETS, DATA BOXES, OVIDE DUMPSTER AND ANY TEMPORARY CONSTRUCTION. AFTER SUBSTANTIAL THE OWNER WILL HAVE 1ST RIGHT OF DISPOSITION DASHED LINES DENOTES WALLS / DOORSTO BE DEMOLISHED IN ITS ENTIRIETY.WALLS TO REMAINHATCH DEFINES WORK AREA NOT INSCOPE 2x2 RETURN AIR VENT 2X2 FLUORESCENT FIXTURE2x4 FLUORESCENT FIXTURE W/ACRYLIC LENSE2x2 LIGHT / FANDOWN LIGHT, RECESSED IN DRYWALLPLASTER OR ACOUSTICAL TILESINGLE POLE SWITCHSPEAKER2x2 SUPPLY DIFFUSEREXIT SIGNSMOKE DETECTORACT - ACOUSTIC CEILING 2'X2' GRID& TILEGYP - GYPBOARDEXP - EXPOSED TO STRUCTURE ANDFLOOR / ROOF ABOVE - BOTTOM OF EXPOSEDSTRUCTURE- BOTTOM OF SLOPE- TOP OF SLOPE- CEILING HEIGHT FOR CODE \[7'-0" AFF ALLOWABLE MIN\].UNUSED WIRING.FLOOR ABOVE. REMOVE ANY ABANDONED WIRES, CONDUIT, OR PIPING.NEW WINDOW.NEEDED.INFORMATION. SD S B.O.E.B.O.S.T.O.S.C.H. GENERAL DEMO NOTES A -- DASHED LINES INDICATE ITEMS TO BE REMOVED SEE OTHER DRAWINGS FORADDITIONAL ITEMS TO BE REMOVED DUE TO NEW CONSTRUCTION. THE PLAN NOTESON THIS SHEET ARE TO AID THE CONTRACTBE REMOVED FOR THE CONTRACTOR TO ESTBIDDING. IT IS THE CONTRACTORS RESPONSIBILITY TO BECOME FAMILIAR WITH ALLNEW CONSTRUCTION AND ANY ADDITIONAL ITEMS TO BE DEMOLISHED TO ACHIEVETHE NEW DESIGN: ANY & ALL FURNISHINGS, EQUIPMENT, FIXTURES, AND/OR DEVICESTO BE REMOVED BY DEMOLITION: OF ITEMS REMOVED BY CONTRACTOR B -- COORDINATE LIGHT FIXTURE & DOOR DEMOLITION W/ OWNER. ANY ITEMSREMOVED FOR THIS PROJECT TO GO TO OWNER. OWNER TO PROVIDE LOCATIONFOR STORAGEC -- ITEMS THAT ARE TO REMAIN THAT ARE DAMAGED DUE TO DEMOLITION OR NEWCONSTRUCTION ARE TO BE REPAIRED OR REPLACED TO OWNER'S SATISFACTIOND -- AT THE END OF DEMOLITION, THE CONTRACTOR IS TO VERIFY GIVEN DIMENSIONSAND NOTIFY THE ARCHITECT OF DISCREPAEXISTING WALLS & COLUMNSE -- COORDINATE WITH EXISTING MEP DRAWINGS FOR ADDITIONAL DEMOLITIONEXTENT & REQUIREMENTSF -- REFER TO ROOM FINISH SCHEDULE FOR FINISH ITEMS TO BE REMOVED SUCH ASWALL COVERINGS & FLOOR COVERINGS. IF THE ROOM FINISH SCHEDULE CALLS FORNEW COVERINGS THEN THE EXISTING IS TO BE REMOVED ENTIRELY AND THE WALL ISTO BE PREPARED FOR NEW FINISHESG -- ALL ABANDONED ELECTRICAL OUTLETS TO BE REMOVED IN THEIR ENTIRETY(INCLUDING DEVICES, CONDUIT, WIRING, ETC.) PATCH WALLS AS REQUIRED FORNEW FINISHES.H -- IT WILL BE THE RESPONSIBILITY OF OWNER TO REMOVE EXISTING LOOSEFURNITURE, ARTWORK, PRIOR TO COMPLETION, OWNER TO RELOCATE ANY LOOSE FURNITURE ITEMS TO BE REUSED.CONTRACTOR TO GIVE 1 WEEK NOTICE PRIOR TO BEGIN OF CONSTRUCTION ANDCOMPLETIONI -- IN LOCATIONS WHERE WALLS ARE REMOVED ON EXTERIOR OR INTERIOR,CONTRACTOR TO PROVIDE TEMPORARY BARRIERJ -- DEMOLITION CONTRACTOR TO PRELECTRICITY/ POWER NEEDED TO COMPLETE WORKK -- REMOVE ALL EXISTING LIGHT FIXTURES, ANY TO REMAIN WILL BE CALLED OUTSPECIFICALLY ON THE PLANS.L -- DIGITAL COPIES OF EXISTING DRAWINGS ARE AVAILABLE- CONTACTARCHITECT FOR ACCESS TO DRAWINGS.M -- THE OWNER WILL PAY FOR TEMPORARY UTILITY COSTS INCURRED BY THECONTRACTOR SINCE BUILDING IS EXISTINGN -- PATCH ALL EXISTING WALLS WHERSURFACE MOUNTED SOAP DISPENSERS, ETC ARE REMOVED.O -- RE-USE ANY EXISTING DOORS AND FRAMES WHERE POSSIBLE.P -- ALL HANGING LIGHT FIXTURES INTERIOR AND EXTERIOR TO BE REMOVEDCOMPLETELYQ -- REMOVE ALL EXISTING BLINDS ABOVE WINDOWS UNLESS NOTED OTHERWISE DEMO CEILING PLAN NOTES DC1HATCHED AREA INDICATES EXPOSED BEAMS WITHIN THE BARN TO REMAINDC2DRYWALL BULKHEAD FOR DUCTWORK TO BE REMOVED COMPLETELY, TOO LOWDC3EXISTING SLOPED CEILING TO REMAIN, PREP FOR NEW PAINT BY REMOVING ANYDC4EXISTING CEILING TO REMAINDC5DEMO HARD CEILING INCLUDING LIGHTS IN PREP FOR EXPOSED CEILING TODC6DEMO FOR NEW INTERIOR WINDOW. REFER TO WINDOW ELEVATIONS FOR SIZE OFDC7EXISTING 8'-0" WALLS TO BE DEMOLISHED IN IT'S ENTIRETY.DC8STAIRCASE AND WALL TO BE DEMOLISHED. PATCH AND REPAIR WALL ASDC9EXISTING TRACK LIGHT TO REMAIN.DC10EXISTING PENDANT LIGHT TO REMAIN.DC11DEMOLISH EXISTING LIGHTS. REFER TO ELECTRICAL FOR ADDITIONALDC12LINE OF DUCT WORK AT CELING LINE.DC13REMOVE EXISTING PLEXIGLASS SHEET. PREP FOR NEW WALL INFILL. REFLECTED CEILING PLAN LEGEND A BCD 35' - 7" 12' - 3"12' - 0"11' - 4" DC6DC6 1/4" = 1'-0" 03 UPPER LEVEL RCP DEMO SCALE: 3'-0"3'-0" 1 DC13 SLOPE UP DC1DC3DC3 DC1 N 12' - 11" PLAN NORTH 19' - 10" DC3DC3 DC3DC3 T.O.S. 04 25' - 7" OPEN TO BELOW 7' - 5 1/2"7' - 5 1/2" B.O.E. 12' - 8" B.O.E. 8' - 6"SLOPE UP 3'-0" B.O.S. 05 DC6 3042 EXISTING EXISTING WALLSAND EXIST. GYP. W/80-120 GRIT SANDPAPER UNTIL PAINT ISREMOVEDAPPLY THIN SETMORTARTILE PER FINISH PLAN P6 LOR. BUILD OUT NEW WALL TO COVER COUNTERTOP W/CASEWORK BELOW. # CHITECT PRIOR TO INSTALLATION FOR OF NEW CONSTRUCTION WITH FACE OF DING/PROJECT STANDARDS. PROVIDE STRUCTIONS ARE CONTAINED HEREIN, 1" 5/8" WOOD CAP5/8" GYP. BOARD3-5/8"" METAL STUDS@ 16" O.C. (MAX.) UP TO 7'-0" AFFUP TO 8'-0" AFF 5/8" TYP. P5 P5A 3 9/16" 4 13/16" 1" FROM FINISH FLOORNEW ROLLING OVERHEAD DOOR. INSTALL ROUGH SAWN CEDAR SIDING TO MATCHEXISTING EXTERIOR.FOR WOOD DOORS. 2.1 M LENGTH STAINLESS STEEL HARDWARE.ELECTRICAL AND DOOR HARDWARE.ADJACENT.MATC H ADJACENT.INTERIOR ELEV. FOR MORE INFO.OPENING WITH 2 1/2" METAL STUDS AND ROUGH SAWN CEDAR PLANKS UP TO7'-0" ALONG ENTIRE LENGTH OF WALL. PLAN NOTES 1EXISTING TO REMAIN.272" TELEVISION MONITOR. PROVIDE BLOCKING AND MOUNTING HARDWARE AT 62"3FIREPLACE TO REMAIN, CLEAN BRICK/STONE.4STANDING HEIGHT SOLID SURFACE 6STAINLESS STEEL SINK.7FILL IN GARAGE DOOR OPENING WITH METAL STUDS & INSULATION. PREP FOR84' X 8' GLASS BOARD PAINTED WHITE ON BACK.98'-0" HIGH ROLLING BARN DOOR USE HAFELE, FLATEC I BARN DOOR HARDWARE10REMOVE EXSITING SHUTTER COUNTER AND FILL IN WITH NEW WINDOW.11CARD ACCESS PROVIDED BY OWNER SECURITY CONTRACTOR. COORDINATE WITH12PORCH OVERHANG.13NEW WATER COOLER. REFER TO PLUMBING.14LOCATION OF CHECK IN STATIONS15INFILL INTERIOR WINDOW W/ STUDS & GYP. ADD WOOD PANELING TO MATCH16INFILL OPENING W/ STUDS & DRYWALL TO MATCH ADJACENT FINISHES.17WATER DISPENSER. REFER TO PLUMBING.18RELOCATE RETURN AIR VENT. PAINT.19INFILL WALL WITH STUDS AND DRYWALL, ADDING A LAYER OF WOOD SLATS TO20NEW INTERIOR WINDOW WITH FIBERGLASS FRAME21ADD BATT INSULATION IN WALL CAVITY22BUILT IN BENCH, SEE 2/A1-223METAL STUD AND DRYWALL CONFIGURED WALL 8'-0" WITH WOOD CAP. SEE2418" FIREPLACE BASE26WALL UP TO 7' WITH NEW ADJUSTABLE SHELVES27PAINT EXISTING PLEXY GLASS SOLID CO GENERAL NOTES A. CONTRACTOR TO FOLLOW ALL BUILINTERIM LIFE SAFETY MEASURES AND FOLLOW ALL STATE AND LOCALBUILDING CODES. IF CONTRARY INREQUEST CLARIFICATION FROM OWNER/ARCHITECT.B. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALLDIMENSIONS, JOB CONDITIONS, ETC.C. NOT USED.D. ALL DIMENSIONS ARE FROM FINISHED FACE TO FINISHED FACE OR COLUMNGRID TO FINISH FACE.E. SEE WALL TYPES, DOORS AND HARDWARE SCHEDULES FOR ADDITIONALINFORMATION.F. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHOULD DO SO UNDERTHE CENTERLINE OF THE DOOR, UNLESS OTHERWISE NOTED.G. HINGE SIDE OF DOOR JAMBS IN METAL STUD WALLS SHALL TYPICALLY BELOCATED 4" FROM ADJACENT WALLS UNLESS OTHERWISE NOTED. SEE TYPICALDETAILS ON DOOR SCHEDULE FOR ADDITIONAL INFORMATION.H. PROVIDE BLOCKING IN NEW AND EXISTING WALLS FOR ALL WALLSUPPORTED ITEMS. SEE PLANS FOR CASEWORK LOCATIONS.I. ALL MATERIALS TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONSAND STANDARD SPECIFICATIONS.J. REFER TO ROOM FINISH SCHEDULE FOR ALL REQUIRED FINISH INFORMATION.K. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTINGEXISTING CONSTRUCTION, ALIGN FACE EXISTING CONSTRUCTION. SKIM ENTIRE WALL SURFACE AS REQUIRED TOPROVIDE SMOOTH, FLUSH TRANSITIONS.L. PROVIDE CONTROL JOINTS IN ALL RUNS OF GYPSUM BOARD. WALLS OVER 30FEET IN LENGTH. COORDINATE WITH ARCOMPLIANCE WITH DESIGN INTENT.M. PREP ALL WALL SURFACES TO RECEIVE NEW PAINT OR WALL COVERINGFINISH. PATCH ALL EXISTING HOLES IN AREAS TO RECEIVE NEW FINISHES. SANDWALLS SMOOTH PRIOR TOPAINTING. PROVIDE BLANK COVER PLATES WHERE NEEDED. REMOVEEMERGENCY LIGHTS, SIGNAGE, THERMOSTATS, FIRE STROBES, ETC. PRIOR TOPAINTING AND REINSTALL WHEN COMPLETE.N. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED WALLS SHALLBE SLEEVED AND FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS.O. ELECTRICAL & PLUMBING FIXTURES SHOWN FOR COORDINATION ONLY, NOTALL FIXTURES SHOWN ON ARCHITECTURAL DRAWINGS.P. NO NEW WORK SHOULD INTERFERE WITH ANY EXISTING DOOR SWINGS ORSIMILAR FUNCTIONAL BUILDING COMPONENTS, CONTACT ARCHITECT WITH ANYCONCERNS PRIOR TO BEGINNING WORK. 6" METAL STUDS@ 16" O.C. (MAX.)5/8" BACKER BOARDTHIN SET MORTARTILE. REFER TO INTERIORS TILE TO DECK. BOARD ABOVE COORDINATE W/INTERIORS DWG PROVIDE 5/8" GYP 2 A5-1 P4 ABE CD 6' - 7"16' - 10"28' - 2" EXISTING WALL COND.1.5"POLYISOCYANURATEFOAM SHEATHING, FOIL-BACKED5/8" GYP. BOARD2 1/2" METAL STUDS@ 16" O.C. (MAX.) FULL HT.TO DUCT 5/8" 126 P3 P3P1A P3 888 108B 2 1/2" P3 4 5/8" P1 UP TO 8' 1 1/2" 111 108 409 SF 108B 81 SF 12' - 4" 270 SF (TYP. AF-4) 22 P1 1/4" = 1'-0" MECH/STOR MEETING ROOM #4 MEETING ROOM #3 17' - 4" MAIN LEVEL PLAN SCALE: FURNACE ¡ 5 5/8" BACKER BOARDTHIN SET MORTAR3 5/8" METAL STUDS@ 16" O.C. (MAX.)TILE. REFER TOINTERIORS .5' - 0"12' - 7" 9 1 1 DECK 1 01 PROVIDE 5/8" ABOVE TILE TO A ¡ 1 0 . 5 P 3 P1A 1 P1A 4 1/4" 3 5/8"5/8" 6' - 9"¡ 02 P2 . 5 3 1 N A 1 P P1A PLAN NORTH 111 108A ¡ 0 ¡ . 10780 . 0 8 12' - 0"154 SF1 12' - 0" 1070 (TYP. AF-4) 112 1 186 SF MEETING ROOM #2 MEETING ROOM #5 7' - 3" 2 5/8" GYP. BOARDEACH SIDE3 5/8" METAL STUDS TD-1 ¡ 0112 . 8 0 1 FULL HT.WALL AT 14'-0" A.F.F. P1A BEAM LINE 6" ABOVE CLG.BD. TO 8'-0" A.F.F. STOP P1A TO DUCT ORIMPACT RESISTANT GYP. 02 P1 P1AP1B 4 7/8" P1A PARTITION TYPES 2 2 5/8"3 5/8"5/8" 1414 (TYP. AF-6) 3' - 0"11' - 4" 109 11 809 SF 106A 203 SF GATHERING ROOM 16' - 4" MEETING ROOM #1 106A 109 20' - 1" (TYP. AF-3) P1A 8 5' - 0" P1A 0" 18 106B (TYP. AF-6) P1 UP 106B STOR39 SF MAIN LEVEL EXISTING ROOF STRUCTUREEXISTING EXTERIOR WALL4' COUNTER COILING DOORANGLE COUNTER DOWN TO DRAINSTAINLESS STEEL CONCESSIONTRANSACTION TOP, MATCH COUNTERHEIGHT TO HEIGHT OF COILING DOORFRAMECOUNTER BRACKET SUPPORTS @ 48" O.C. MAX5/8" DENSE GLASSVAPOR BARRIER5/8" GYP BOARDAIR BARRIEREXT ROUGH SAWN CEDAR SIDINGTO MATCH EXISTING SEE A8-1 FOR DETAILSEXISTING CMU LINTEL 03 114C ICE 6'-0"3'-7" MW 2'-1" TILE 4 WALL 2 17 11 105 4' - 0" 105 06 6 MECHANICAL/STORAGE P6 (TYP. AF-4) 4' - 1" 3'-0" 1 A5-1 REF. 4 7'-0" 3/4" = 1'-0" 11' - 0" 114 842 SF 04 25' - 4" ALTERNATE CONCESSION DOOR INFILL SCALE: 13 MEETING ROOM #6 P1A 1 A9-1 2 3'-2" 104 104 3' - 0"3' - 4" WOMENS RR 31' - 10" 13' - 3" (TYP. AF-4) 12' - 9" 19191919 16 2 P6 114A 15 3' - 9" 21 P1AP1A 114B 05 UP B10215 3' - 0"3' - 8"6' - 0"3' - 7" RETURN TILE P4 116 WALL CORRIDOR 21 P2 (TYP. AF-6) P2 P1A 13'-0 1/2"103 MENS RR 103 116 512 SF 1414 2 P1A ABOVE 19' - 8" 16 MEETING RM #7 (TYP. AF-6) 21 100B 24 DOUBLE PANE INSULATEDGLAZINGWALL BEYONDMETAL END CAP. GORDON 911-EC-487INTERIOR WALLCONSTRUCTIONACOUSTICAL SEALANTINSULATED ALUMN. FRAME MULLION LIQUID APPLIED WATERCONTROL LAYEREXISTING CMUROUGH SAWN CEDAR SIDING2X4 WOOD FURRING TAP CONNEDINTU CMU @ 16" O.C. 4' - 2"10' - 0" 3 P1A 21 7' - 0" 101 06 5' - 8"4 STAND101 100 (TYP. AF-6) A1-1 4' - 1" CONCESSION VESTIBULE 06 101B100A 11 11 6'-0" (TYP. AF-6) 1 1/2" = 1'-0" 1 1/2" = 1'-0" 11(TYP. AF-6) 7 2 2 TYP. WALL JOIN AT WINDOW FRAME SCALE:EXTERIOR CONCESSION DETAIL SCALE: A1-1 3 A4-2 A1-1 13' - 8" 34 12' - 5"7' - 3"28' - 1" 3042 KING AND MOUNTING HARDWARE AT 62" , ADDING A LAYER OF WOOD SLATS TO E COUNTERTOP W/CASEWORK BELOW. # ILDING/PROJECT STANDARDS. PROVIDE FROM FINISH FLOORNEW ROLLING OVERHEAD DOOR. INSTALL ROUGH SAWN CEDAR SIDING TO MATCHEXISTING EXTERIOR.FOR WOOD DOORS. 2.1 M LENGTH STAINLESS STEEL HARDWARE.ELECTRICAL AND DOOR HARDWARE.ADJACENT.MATC H ADJACENT.INTERIOR ELEV. FOR MORE INFO.OPENING WITH 2 1/2" METAL STUDS AND ROUGH SAWN CEDAR PLANKS UP TO7'-0" ALONG ENTIRE LENGTH OF WALL. GENERAL NOTES A. CONTRACTOR TO FOLLOW ALL BUINTERIM LIFE SAFETY MEASURES AND FOLLOW ALL STATE AND LOCALBUILDING CODES. IF CONTRARY INSTRUCTIONS ARE CONTAINED HEREIN,REQUEST CLARIFICATION FROM OWNER/ARCHITECT.B. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALLDIMENSIONS, JOB CONDITIONS, ETC.C. NOT USED.D. ALL DIMENSIONS ARE FROM FINISHED FACE TO FINISHED FACE OR COLUMNGRID TO FINISH FACE.E. SEE WALL TYPES, DOORS AND HARDWARE SCHEDULES FOR ADDITIONALINFORMATION.F. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHOULD DO SO UNDERTHE CENTERLINE OF THE DOOR, UNLESS OTHERWISE NOTED.G. HINGE SIDE OF DOOR JAMBS IN METAL STUD WALLS SHALL TYPICALLY BELOCATED 4" FROM ADJACENT WALLS UNLESS OTHERWISE NOTED. SEE TYPICALDETAILS ON DOOR SCHEDULE FOR ADDITIONAL INFORMATION.H. PROVIDE BLOCKING IN NEW AND EXISTING WALLS FOR ALL WALLSUPPORTED ITEMS. SEE PLANS FOR CASEWORK LOCATIONS.I. ALL MATERIALS TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONSAND STANDARD SPECIFICATIONS.J. REFER TO ROOM FINISH SCHEDULE FOR ALL REQUIRED FINISH INFORMATION.K. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTINGEXISTING CONSTRUCTION, ALIGN FACE OF NEW CONSTRUCTION WITH FACE OFEXISTING CONSTRUCTION. SKIM ENTIRE WALL SURFACE AS REQUIRED TOPROVIDE SMOOTH, FLUSH TRANSITIONS.L. PROVIDE CONTROL JOINTS IN ALL RUNS OF GYPSUM BOARD. WALLS OVER 30FEET IN LENGTH. COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION FORCOMPLIANCE WITH DESIGN INTENT.M. PREP ALL WALL SURFACES TO RECEIVE NEW PAINT OR WALL COVERINGFINISH. PATCH ALL EXISTING HOLES IN AREAS TO RECEIVE NEW FINISHES. SANDWALLS SMOOTH PRIOR TOPAINTING. PROVIDE BLANK COVER PLATES WHERE NEEDED. REMOVEEMERGENCY LIGHTS, SIGNAGE, THERMOSTATS, FIRE STROBES, ETC. PRIOR TOPAINTING AND REINSTALL WHEN COMPLETE.N. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED WALLS SHALLBE SLEEVED AND FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS.O. ELECTRICAL & PLUMBING FIXTURES SHOWN FOR COORDINATION ONLY, NOTALL FIXTURES SHOWN ON ARCHITECTURAL DRAWINGS.P. NO NEW WORK SHOULD INTERFERE WITH ANY EXISTING DOOR SWINGS ORSIMILAR FUNCTIONAL BUILDING COMPONENTS, CONTACT ARCHITECT WITH ANYCONCERNS PRIOR TO BEGINNING WORK. 3 5/8" METAL STUD @ 16" O.C.OPENING FOR CHASE AS NEEDEDBY MEP CONTRACTORTRIM PER FINISH PLAN 5/8" GYP BOARD FINISH1 1/2" SOLID WOOD SEATSEALANT4"X4"X1/4" STEEL ANGLE FORSUPPORT FASTENED TOEXISTING STRUCTURE @EVERY STUD CONTINUOUSALONG WALL5/8" GYP BOARD PLAN NOTES 1EXISTING TO REMAIN.272" TELEVISION MONITOR. PROVIDE BLOC3FIREPLACE TO REMAIN, CLEAN BRICK/STONE.4STANDING HEIGHT SOLID SURFAC6STAINLESS STEEL SINK.7FILL IN GARAGE DOOR OPENING WITH METAL STUDS & INSULATION. PREP FOR84' X 8' GLASS BOARD PAINTED WHITE ON BACK.98'-0" HIGH ROLLING BARN DOOR USE HAFELE, FLATEC I BARN DOOR HARDWARE10REMOVE EXSITING SHUTTER COUNTER AND FILL IN WITH NEW WINDOW.11CARD ACCESS PROVIDED BY OWNER SECURITY CONTRACTOR. COORDINATE WITH12PORCH OVERHANG.13NEW WATER COOLER. REFER TO PLUMBING.14LOCATION OF CHECK IN STATIONS15INFILL INTERIOR WINDOW W/ STUDS & GYP. ADD WOOD PANELING TO MATCH16INFILL OPENING W/ STUDS & DRYWALL TO MATCH ADJACENT FINISHES.17WATER DISPENSER. REFER TO PLUMBING.18RELOCATE RETURN AIR VENT. PAINT.19INFILL WALL WITH STUDS AND DRYWALL20NEW INTERIOR WINDOW WITH FIBERGLASS FRAME21ADD BATT INSULATION IN WALL CAVITY22BUILT IN BENCH, SEE 2/A1-223METAL STUD AND DRYWALL CONFIGURED WALL 8'-0" WITH WOOD CAP. SEE2418" FIREPLACE BASE26WALL UP TO 7' WITH NEW ADJUSTABLE SHELVES27PAINT EXISTING PLEXY GLASS SOLID COLOR. BUILD OUT NEW WALL TO COVER A 1'-8" 2 A5-1 1 1/2" = 1'-0" E ABCD LOFT BENCH SCALE: 1'-6" 2 12' - 3"12' - 0"11' - 4"18' - 8" NOTE: COORDINATE WITHINTERIOR DETAILSBUILD UP WITH METALSTUDS AND 5/8" GYPBOARD ON ALL SIDES. CAPWITH DRYWALL EDGE UP TO8' AFFBUILD UP TO7'-0" AFF 1' - 4" 9" 1' - 9" 01 4' - 0" 1" = 1'-0" LOFT LEVEL DETAIL SCALE: 12' - 5" 3 02 EXISTING EXISTING WALLSAND EXIST. GYP. W/80-120 GRIT SANDPAPER UNTIL PAINT ISREMOVEDAPPLY THIN SETMORTARTILE PER FINISH PLAN P6 20' - 4" OPEN TO FLOOR BELOW 1" 5/8" WOOD CAP5/8" GYP. BOARD3-5/8"" METAL STUDS@ 16" O.C. (MAX.) UP TO 7'-0" AFFUP TO 8'-0" AFF 35' - 7"5/8" 35' - 3" TYP. P5 P5A 3 9/16" (TYP. AF-5)(TYP. AF-5) 4 13/16" 1" DN 201 8' - 3" STOR39 SF 201203 03 20 20 6" METAL STUDS@ 16" O.C. (MAX.)5/8" BACKER BOARDTHIN SET MORTARTILE. REFER TO INTERIORS P5 DN 200 83 SF 3 VESTIBULE TILE TO DECK. EXISTINGAF-2BOARD ABOVE A1-2 COORDINATE W/INTERIORS DWG PROVIDE 5/8" GYP 12' - 11" 26 27 P4 200 P2A 1 A5-1 4' - 4" P2A 11 04 25' - 7" 25' - 2" 23 OPEN TO FLOOR BELOW 203 785 SF 2 A1-2 EXISTING WALL COND.1.5"POLYISOCYANURATEFOAM SHEATHING, FOIL-BACKED5/8" GYP. BOARD2 1/2" METAL STUDS@ 16" O.C. (MAX.) MEETING ROOM #8 5/8"FULL HT.TO DUCT 14' - 6" DN 12' - 8" 2 1/2" P3 4 5/8" 22 27 20 1 1/2" 27 202 05 5/8" BACKER BOARDTHIN SET MORTAR3 5/8" METAL STUDS@ 16" O.C. (MAX.)TILE. REFER TOINTERIORS (TYP. AF-5) DECK 202 108 SFPROVIDE 5/8" ABOVE TILE TO MECHANICAL 4 1/4" 3 5/8"5/8" P2 OPEN TO FLOOR BELOW 1/4" = 1'-0" 19' - 11" UPPER LEVEL PLAN SCALE: 1 5/8" GYP. BOARDEACH SIDE3 5/8" METAL STUDS TD-1 FULL HT.WALL AT 14'-0" A.F.F. BEAM LINE 6" ABOVE CLG.BD. TO 8'-0" A.F.F. STOP TO DUCT ORIMPACT RESISTANT GYP. N P1 P1A 4 7/8"P1B PLAN NORTH PARTITION TYPES 5/8"3 5/8"5/8" 06 3042 EXISTING SLOPED CEILINGEXISTING 4" WIDE BEAM TO BEEXPOSED AND PAINTEDMAINTAIN A 2" GAP TOSHOW BEAMNEW 1/2" GYP. BOARDNEW 1/2" GYP. BOARD AND METALSTUDS TO MAINTAINT 2" OFFSETFROM EXISTING BEAMALLIGN NEW WALL WITHBULKHEAD ABOVE FINISH PLAN. C# FINISH PLAN. . SEE ELECTRICAL AND HVAC PLANS FOR E TAKEN FINISHED FACE TO FINISHED FACE. WITH STRUCTURE, BULKHEAD AND CEILING TO NISH PLAN. PATCH ANY OPENINGS/ HOLES 10' - 0" PAINTED. REFER TO 12' - 0" PAINTED. REFER TO 2" 01 1 1/2" = 1'-0" STRUCTURAL SECTION 1 SCALE: 2X2 FLUORESCENT FIXTURE2x4 FLUORESCENT FIXTURE W/ACRYLIC LENSE2x2 LIGHT / FANDOWN LIGHT, RECESSED IN DRYWALLPLASTER OR ACOUSTICAL TILESINGLE POLE SWITCHSPEAKER2x2 SUPPLY DIFFUSER2x2 RETURN AIR VENTEXIT SIGNSMOKE DETECTORACT - ACOUSTIC CEILING 2'X2' GRID& TILEGYP - GYPBOARDEXP - EXPOSED TO STRUCTURE ANDFLOOR / ROOF ABOVE - BOTTOM OF EXPOSEDSTRUCTURE- BOTTOM OF SLOPE- TOP OF SLOPE- CEILING HEIGHT PRIOR TO PAINTING.PATCHED TO CREATE SMOOTH CEILING WITH ADJACENT ELEVATION TO ESIXTINGHARD CEILING 2 SD DECK CLEARANCES PRIOR TO STARTING WORK.FIXTURE COUNTS AND TYPES.MAINTAIN MINIMUM EDGE TILE AT 6".S B.O.E.B.O.S.T.O.S.C.H. 3 5/8" METALSTUD @ 16 O.C. A.DIMENSIONS ON REFLECTED CEILING PLAN ARE.UNLESS OTHERWISE NOTED/SHOWN - CENTER NEW GRID EACH DIRECTION IN ROOM.F.MUST MAINTAIN MIN 7'-0" IN CEILING HEIGHT. B.SEE ELECTRICAL FOR SWITCHING OPERATION AND LOCATION.C.COORDINATE ALL DUCTWORK AND LIGHTING D.LIGHTS AND DIFFUSERS SHOWN FOR LOCATION CEILING PLAN NOTES C1EXISTING HARD CEILING TO BE PAINTED, SMOOTH WHERE NEEDEDC2EXISTING TO REMAIN.C3NEW GYP HARD SURFACE CEILING OR BULKHEADC42 X 2 ACOUSTICAL TILE AND GRID. REFER TO FINISH PLAN AND SPECS.C5LINE OF EXISTING BEAMS TO BE C6LINE OF EXISTING BULKHEAD TO BEC7PAINT EXPOSED CEILING. REFER TO FIC8CEILING CONTINUES TO SLOPE UP. REFER TO D2-1 FOR HEIGHTSC9HATCHED AREA INDICATES LOW BULKHEAD AREA THAT WAS REMOVED AND NEEDSC10GYP BULKHEAD TO BE PAINTEDC11GYP. CONTROL JOINT DETAIL SEE DETAIL 3/A2-1C12CLEAN, PREP AND PAINT EXISTING SOFFIT AND BEAMS. REFLECTED CEILING PLAN LEGEND REFLECTED CEILING GENERAL NOTES E ABCD 5/8" GYP BOARD SLOPE UP 9' - 10" 1/2" B.O.S. NEW WALL UP TOEXISTING CEILINGNEW WALL UP TOEXISTING CIELING 108EXP C2C2 EXPC7C7 111 108BEXP MECH/STOR MEETING ROOM #3 MEETING ROOM #4 12" = 1'-0" 2 A2-1 12' - 0" GYP. CONTROL JOINT DETAIL SCALE: B.O.E. 01 3 C11 C11 C3C3 10' - 0" C3C3 10' - 0" B.O.E. BOTTOM OF 12' WALL UP TOEXPOSED BEAM C5C5 112 C5C5 107 ACT C12 12' WALL UP TO 10' - 0" A.F.F. MEETING ROOM #5 10' - 0" MEETING ROOM #2 C3C3 8' WALL UP TO B.O.E.8' WALL UP TOBOTTOM OFEXPOSED BEAM ACT C8 10' - 0" A.F.F. 02 C11 C11 8' - 0" 9' - 5" B.O.E. B.O.S.C7C7 SLOPE UP C7C7 EXP 106A NEW WALLS UP TOEXISTING CEILING SLOPE UP C7C7 MEETING ROOM #1109 EXP C12C12 GATHERING ROOM T.O.S. SLOPE UP B.O.S. 11' - 8" 16' - 0" EXPC2C2 106B STOR 03 C5 C5 105C2C2 EXP C12 7' - 8" 6' - 8" MECHANICAL/STORAGE 7' - 4" 7' - 8" 7' - 8" C2C2 EXP C5 C5 C7C7 04 C7C7 114 EXP SLOPE UP B.O.S. MEETING ROOM #6 10' - 5" B.O.E. T.O.S. 16' - 0"9' - 6" C4C4 C7C1 104 C5 7' - 0"EXP 6' - 8" WOMENS RR ACT 7' - 0" A.F.F. 05 7' - 0" EXP B102 14' - 2" C4C4 16' - 0" ACT CORRIDOR B.O.E. 6' - 8" 7' - 0" A.F.F. C5 T.O.S. C7C7 C5 B.O.S. 11' - 8" 5" 9' - 6" GYP 6' - 8" A.F.F. 9' - 6" C10 C5 116EXPC7C7 1/4" = 1'-0" 103 C12C12 ACT 8' - 6" MENS RR C4C4 8' - 6" A.F.F. MEETING RM #7 MAIN LEVEL RCP SCALE: 1 B.O.S. C7C7 100 EXP C7C7 9' - 5" 101EXP VESTIBULE STAND CONCESSION N PLAN NORTH 06 2 A1-1 3042 C# FINISH PLAN. FINISH PLAN. . SEE ELECTRICAL AND HVAC PLANS FOR E TAKEN FINISHED FACE TO FINISHED FACE. NISH PLAN. PATCH ANY OPENINGS/ HOLES PAINTED. REFER TO PAINTED. REFER TO 2x2 RETURN AIR VENT 2X2 FLUORESCENT FIXTURE2x4 FLUORESCENT FIXTURE W/ACRYLIC LENSE2x2 LIGHT / FANDOWN LIGHT, RECESSED IN DRYWALLPLASTER OR ACOUSTICAL TILESINGLE POLE SWITCHSPEAKER2x2 SUPPLY DIFFUSEREXIT SIGNSMOKE DETECTORACT - ACOUSTIC CEILING 2'X2' GRID& TILEGYP - GYPBOARDEXP - EXPOSED TO STRUCTURE ANDFLOOR / ROOF ABOVE - BOTTOM OF EXPOSEDSTRUCTURE- BOTTOM OF SLOPE- TOP OF SLOPE- CEILING HEIGHT DECK CLEARANCES PRIOR TO STARTING WORK.FIXTURE COUNTS AND TYPES.MAINTAIN MINIMUM EDGE TILE AT 6". PRIOR TO PAINTING.PATCHED TO CREATE SMOOTH CEILING WITH ADJACENT ELEVATION TO ESIXTINGHARD CEILING A.DIMENSIONS ON REFLECTED CEILING PLAN ARB.SEE ELECTRICAL FOR SWITCHING OPERATION AND LOCATION.D.LIGHTS AND DIFFUSERS SHOWN FOR LOCATIONE.UNLESS OTHERWISE NOTED/SHOWN - CENTER NEW GRID EACH DIRECTION IN ROOM.F.MUST MAINTAIN MIN 7'-0" IN CEILING HEIGHT.SD C.COORDINATE ALL DUCTWORK AND LIGHTING WITH STRUCTURE, BULKHEAD AND CEILING TO S B.O.E.B.O.S.T.O.S.C.H. REFLECTED CEILING GENERAL NOTES CEILING PLAN NOTES C1EXISTING HARD CEILING TO BE PAINTED, SMOOTH WHERE NEEDEDC2EXISTING TO REMAIN.C3NEW GYP HARD SURFACE CEILING OR BULKHEADC42 X 2 ACOUSTICAL TILE AND GRID. REFER TO FINISH PLAN AND SPECS.C5LINE OF EXISTING BEAMS TO BE C6LINE OF EXISTING BULKHEAD TO BEC7PAINT EXPOSED CEILING. REFER TO FIC8CEILING CONTINUES TO SLOPE UP. REFER TO D2-1 FOR HEIGHTSC9HATCHED AREA INDICATES LOW BULKHEAD AREA THAT WAS REMOVED AND NEEDSC10GYP BULKHEAD TO BE PAINTEDC11GYP. CONTROL JOINT DETAIL SEE DETAIL 3/A2-1C12CLEAN, PREP AND PAINT EXISTING SOFFIT AND BEAMS.REFLECTED CEILING PLAN LEGEND 2 A5-1 E ABCD 01 02 35' - 7" 12' - 3"12' - 0"11' - 4" C2C2 03 SLOPE UP 200 C3C3 83 SF EXP VESTIBULE 12' - 11" 1 19' - 10" A5-1 TOP OF SLOPE @ BOTTOM OF UPPER RIDGE C7C7 04 25' - 7" 12' - 8" 8' - 6"SLOPE UP BOTTOM OF SLOPE 05 C2C2 1/4" = 1'-0" UPPER LEVEL RCP SCALE: 1 N PLAN NORTH 06 3042 E# AND COORDINATE DEMOLITION OR ILINGS, STRINGERS, AND STEPS. SCHEDULE FOR DETAILS INFORMATION ON WALL CONSTRUCTION AND FINISH TECHNIQUES.REMOVAL WORK WITH CORRESPONDING NEW CONSTRUCTION WORK ANDAPPROPRIATE TRADES PRIOR TO STARTING DEMO WORK. IFDISCREPANCIES ARE FOUND BETWEEN CONTRACT DOCS. AND ACTUALFIELD CONDITIONS, NOTIFY ARCHTIECT.EXTERIOR WOOD PANELS TO CREATE CONSISTANT LOOK.MATCH WITH EXISTING SIDING. 1.REFER TO ALL SECTION AND DETAIL SHEETS FOR ADDITIONAL2.FIELD VERIFY EXISTING CONDITIONS GENERAL ELEVATION NOTESELEVATION NOTES E1PREP AND PAINT EXISTING SURFACE. USE P-1. USE MATCHINGE2NEW ALUMINUM WINDOWE3NEW DOOR, REFER TO DOORE48" HIGH ACRYLC LETTERS 2" THICK. MOUNT TO END OF ROOF.E5PROVIDE NEW ROUGH SAWN CEDAR SIDING TO ALLIGN ANDE6CLEAN, PREP AND PAINT TRIM.E7REMOVE EXISTING SIGNAGE.E8CLEAN, PREP, AND PAINT CHIMNEY.E9CLEAN, PREP, AND PAINT ALL RA 0" 8' - 0" MAIN LEVEL UPPER LEVEL 0" 8' - 0" MAIN LEVEL UPPER LEVEL 1/4" = 1'-0" 1/4" = 1'-0" SOUTH ELEVATION SCALE:NORTH ELEVATION SCALE: 12 E6 06 E2 E1 E8 E6 01 E2 E1E1 05 02 E9 E2 E6 E1 E3 E6 04 E2 E1E1 03 E9 E6 03 E1 E2 E6 04 E1 E2 02 05 E2 E6 LINE OF EXISTING DOORTO BE PATCHED E7 E2 E5 01 E8 E2 06 3042 E# S AND COORDINATE DEMOLITION OR ILINGS, STRINGERS, AND STEPS. SCHEDULE FOR DETAILS EXTERIOR WOOD PANELS TO CREATE CONSISTANT LOOK.MATCH WITH EXISTING SIDING. INFORMATION ON WALL CONSTRUCTION AND FINISH TECHNIQUES.REMOVAL WORK WITH CORRESPONDING NEW CONSTRUCTION WORK ANDAPPROPRIATE TRADES PRIOR TO STARTING DEMO WORK. IFDISCREPANCIES ARE FOUND BETWEEN CONTRACT DOCS. AND ACTUALFIELD CONDITIONS, NOTIFY ARCHTIECT. ELEVATION NOTES E1PREP AND PAINT EXISTING SURFACE. USE P-1. USE MATCHINGE2NEW ALUMINUM WINDOWE3NEW DOOR, REFER TO DOORE48" HIGH ACRYLC LETTERS 2" THICK. MOUNT TO END OF ROOF.E5PROVIDE NEW ROUGH SAWN CEDAR SIDING TO ALLIGN ANDE6CLEAN, PREP AND PAINT TRIM.E7REMOVE EXISTING SIGNAGE.E8CLEAN, PREP, AND PAINT CHIMNEY.E9CLEAN, PREP, AND PAINT ALL RA 1.REFER TO ALL SECTION AND DETAIL SHEETS FOR ADDITIONAL2.FIELD VERIFY EXISTING CONDITION GENERAL ELEVATION NOTES 0" 0" 8' - 0" 1/4" = 1'-0" 1/4" = 1'-0" 8' - 0" MAIN LEVEL EAST ELEVATION SCALE:WEST ELEVATION SCALE: MAIN LEVEL UPPER LEVEL UPPER LEVEL 12 E A 3'-0" B E2 D 2 A5-1 E1 C C 2 A5-1 E2 E4 D E3 B E5 A E 3042 0" 8' - 0" MAIN LEVEL UPPER LEVEL 9' - 5" 06 100 51 SF VESTIBULE B102 89 SF CORRIDOR 16' - 0" 8' - 6" KEEP COLOUMNS AND HORIZONTAL BRACING IN TACT 05 BOTTOM OF SLOPE 203 785 SF TOP OF SLOPE 19' - 10" MEETING ROOM #8 04 0" 8' - 0" 1 KEEP COLOUMNS AND HORIZONTAL BRACING IN TACTNEW BOOK CASE. VESTIBULE SIDE. A5-1 MAIN LEVEL FROM UPPER LEVEL UPPER LEVEL 17' - 0" 114 842 SF A MEETING ROOM #6 200 83 SF VESTIBULE 03 105 136 SF MECHANICAL/STORAGE EXISTING TO REMAIN 16' - 0" B TOP OF SLOPE 2 A5-1 BOTTOM OF SLOPE 9' - 5" 109 809 SF 6' - 8" GATHERING ROOM C 02 8' - 0" 203 785 SF MEETING ROOM #8 114 842 SF MEETING ROOM #6 BOTTOM OF STRUCTURE 6' - 8" D 01 10' - 0" BOTTOM OF BEAM 16' - 0"9' - 6"108 270 SF BOTTOM OF STRUCTURE MEETING ROOM #3 NEW WALL TO COVER OPENINGSFROM MAIN LEVEL E 10' - 5" 1/4" = 1'-0" 1/4" = 1'-0" FROM MAIN LEVEL NORTH/SOUTH SECTION SCALE:EAST/WEST SECTION SCALE: 12 3042 42" MIN. 54" MIN. WHITE 8" TALL CAPS ROTATED X 24" 12" 4 7/8" NOTE:Y = 48" MIN. IF DOOR HASBOTH A LATCH & CLOSER 42" MIN. SEE SCHEDULE SHIMSCHEDULED PARTITION5/8" GYP BD.GYP. BD. CORNERBEAD (IF REQUIRED) 3-5/8" MTL. STUDw/ 5/8" GYP.(2) 3-5/8" METALBOARD EACH SIDESTUDSSEALANT EACH SIDEHOLLOW METAL DOORFRAMEDOOR AS SCHEDULED NOTES A - ALUM FRAMES TO BE DARK BRONZE MANUFACTURED FINISHSTEEL FRONT.B - ADD WINDOW FILM TO DOOR 100A NEW ENTRY DOOR. FILMTO SAY "MAIN ENTRY" IN VERTICALLYC - ALL DOOR HARDWARE TO BE CENTERED BETWEEN 30" A.F.F.TO 44" A.F.F.D - ALL DOORS (INTERIOR & EXTERIOR) TO HAVE A MAXIMUMOPENING FORCE OF 5 LBS.E - ALL THRESHOLDS TO BE 1/2" MAXIMUM A.F.F. ANY CHANGEIN LEVEL BETWEEN 1/4: A.F.F. TO 1/2" A.F.F. TO BE BEVELED WITHSLOPE NO GREATER THAN 1:2 (RISE:RUN).F - EXTERIOR HOLLOW METAL DOORS TO BE INSULATED.G - ALL EXTERIOR DOORS TO HAVE FULL PERMITER WEATHERSEALS.H - INTERIOR SOLID CORE FACTORY FINISHED DOORS TO BEFLUSH WOOD DOORS. MANUFACTURE OSHGOSHARCHITECTURAL DOOR COMPANY. FACTORY FINISH ALLOPENINGS AND TRIM LIKE OPENING WITH MOLDING. ARCH. TOSELECT FINISH.1/2" D DOOR JAMB 4" SEE SCHEDULE VARIES +/- 5 7/8" 1/2" X 2" HM HEAD DETAIL ALUM. JAMB DETAILS SCHD. FRAME 24" CASEDOPENINGSEE SCHEDULE SCHD. DOOR HINGE SIDE APPROACHES 2" DOOR JAMB WITH SIDELITE C Y NOTE:x = 36" MIN. IF Y = 60";X = 42" MIN. IF Y = 54" Y 2" 48" MIN. SEE SCHEDULENOTE:Y = 54" MIN. IF DOOR HAS CLOSER 2" GL-1 ORGL-2 8"5'-4"1'-0" 6" WALL GUARD VARIES 6" +/- 5 7/8" 18"3 5/8" METALSTUDS5/8" GYP BOARD(2) 3-5/8" METALSTUDSCAULK (BOTH SIDES)HOLLOW METALDOOR FRAME SCHD. GLASSSCHD. TRANSOMSCHD. ALUM FRAMESCHD. DOOR 2" AB ADA APPROACH LEGEND CENTER HUNG T-BAR FORCONCEALED CLOSER X 12" 60" MIN.HM JAMB DETAIL ALUM. T BAR VARIES DOOR & WINDOW ABBREVIATIONSDOOR ELEVATIONS SEE SCHEDULE SCW=SOLID CORE WOODHCW=HOLLOW CORE WOODHM=HOLLOW METALALUM=ALUMINUMTME=TO MATCH EXISTINGPMR=PER MANUFACTURERS RECOMMENDATIONSIG=1" INSULATED GLASS.TG=1" CLEAR TEMPERED GLASS.SSV=STAIN STEAL VARNISHPFN=PREFINISHEDAFF=ABOVE FINISHED FLOORETR=EXISTING TO REMAIN DETAIL - DOOR JAMB @ STOP MIN. SEE SCHEDULE FRONT APPROACHES 48" MIN.NOTE:x = 12" MIN. IF DOOR HASBOTH A LATCH & CLOSER HM DETAILS DRIVE ENDCOUNTER TOP41-1/2" A.F.F. 4' - 0" B 3' - 4" 2" 2"2' - 8" 6" 2" IG B Remarks SEE SCHED A A SEE SCHEDULE FOR DOOR TYPE 3' - 0"2' - 8" 5'-5 5/8" 6'-0" V.I.F. 2" (TYP. AF-3) SEE SCHEDULE D FRAME - EXISTING TO REMAIN - PREP FOR CARD ACCESS 2" 2" COILING DOOR - (101B) SEE SCHEDULE 2" 2" 6" TENSION END 2-3/8" Details VARIES SEE SCHED 5' - 0" 6" 2 1/2"4' - 7"2 1/2" 2" 2-1/8"SECTION B-B BEYOND 8"VARIES1' - 0" CURTAIN (TYP. HM -2)(TYP. HM -1) 2 1/2" HEADPLATE IG 1' - 8"2' - 0" Hardware EQ 2 1/2" IG (EXTERIOR)MIN 8" SLOPEDTO DRAINRIGHT HANDOPERATIONSHOWN, LEFTHANDOPPOSITE EQ MR#ALUMSEE COUNTER DOOR DETAILS FOR MORE INFORMATION BELOW. 8" 2 1/2" IGADD 3M FILM PRIVACY TODOOR @ MEETING ROOMS 9' - 10" V.IF A EQ (TYP. AF-4) UPSET1' - 6" SECTION A-A INSIDE FACE-OF-WALL MOUNTEDSERIES 650 A 2 1/2" 4'-0" IG 1" TypeMaterialFinishJambHead EQ HOOD CURLSQUAREHOODMAX DOOR 2 1/2" Fire CONCESSIONS Rating 2' - 0" 7' - 0" STAINLESS STEEL DOOR SCHEDULE TMETME TRANSACTION TOP. COUNTER BRACKET (INTERIOR) TO ALIGN W/ COILING SUPPORTS AT 36" O.C. MATCH COUNTER HEIGHT 4'-0" TG SEE SCHEDULE SEE SCHEDULE FOR DOOR TYPE 3'-0" 2" 2" DoorFrame(TYP. AF-1) FULLY OPEN LINE"HAFELE FLATEC 1"HANGING HARDWARE"HAFELE FLATEC1" 3' TALL GRABBARWALL OPENING LINE1' 3/4" SOLIDCORE WOODDOOR SEE SCHEDULE (TYP. AF-5) 3' - 0" 3' - 0" 3'-0" 3M FILM SAYING"MEETING ROOM #1"USE DOOR HM-2 FOROTHER MEETINGROOMS, 2" HIGHLETTERS 5' - 0" 2 1/2"4' - 7"2 1/2" 2" 2 1/2" IG 6' -0" WALL OPENING COMMENTS 3' - 0" EQ 3'-0" SEE SCHEDULE FOR DOOR TYPE 2" .............. 2" IG 3' - 0" 5' - 0" V.IF 4' - 0" SLIDING DOOR - (114B) EQ 1' - 8" (TYP. AF-6) 2" (TYP. AF-2) 7' - 0" Door 2 1/2" 3' - 10"2"2' - 10" 7' - 0" 2' - 0" TMETME 100A3' - 0"7' - 0"BALUMNPFNAF-1ALUMNPFN#ALUMCARD ACCESS. PROVIDE ELECTRICAL100B3' - 0"7' - 0"BSCWSSVHM-2HMPAINT#021013' - 0"7' - 0"ASCWSSVHM-1HMPAINT#05101B6' - 0"7' - 2 1/2"SEE FRAME ELEVATIONALUMNPMRCOILINGALUMNP1033' - 0"7' - 0"ASCWSSVHM-1HMPAINT#021043' - 0"7' - 0"ASCWSSVHM-1HMPAINT#031053' - 0"7' - 0"ASCWSSVHM-1HMPAINT#04106A3' - 0"7' - 0"BSCWSSVHM-2HMPMR#05106B3' - 0"7' - 0"ASCWSSVHM-2HMPAINT#041073' - 0"7' - 0"BSCWSSVHM-2HMPAINT#06108A3' - 0"7' - 0"BSCWSSVHM-2HMPAINT#06108B3' - 0"7' - 0"ASCWSSVHM-1HMPAINT#041096' - 0"7' - 0"BHMPAINTHM-1HMPAINT#08CARD ACCESS1113' - 0"7' - 0"BSCWSSVHM-2HMPAINT#061123' - 0"7' - 0"BSCWSSVHM-2HMPAINT#06114A3' - 0"7' - 0"BSCWSSVHM-2HMPAINT#07114B3' - 0"7' - 0"SEE FRAME ELEVATIONSCWSSVBARNHMPAINT#09SLIDING DOOR114C6' - 0"7' - 0"ETRASCWSSVETRETRETR#01PATCH AND PREP FOR NEW HARDWARE. REMOVE BLINDS1163' - 0"7' - 0"BSCWSSVHM-2HMPMR#071262' - 6"6' - 8"ETRASCWSSVETRETRETRETR2003' - 0"7' - 0"ETRBALUMNPMRAF-2 ETRETR#ALUMDOOR AN2013' - 0"7' - 0"ASCWSSVETRETRETRETR2023' - 0"7' - 0"ETRASCWSSVETRETRETRETR2033' - 0"7' - 0"ETRBSCWSSVETRETRETR#ALUMNEW HARDWARE NumberWidthHeightFire RatingTypeMaterialFinish 3042 T# NG WORK IN AND NEAR THE RESTROOMS L SIZE TILES ON EACH END OF PARTITION. INTAIN ALL CLEARANCES NOTED, AND AREA, BUT MAY NOT OVERLAP THE ACTUAL WALLS FOR ALL TOILET ROOM ACCESSORIES BAR WITH AN 18" VERTICAL GRAB BAR REFERENCE INTERIOR FOR MATERIAL. TH STAINLESS GROMMET 2" DEEP. D, CONTRACTOR INSTALLED. TOILET ROOM GENERAL NOTES AND PARTITIONS FOR OWNER AND CONTRACTOR SUPPLIED ITEMS.SEE SPECIFICATIONS.SHALL CONFIRM THEIR WORK EFFORTS, MACOORDINATE CLEARANCES REQUIRED WITH ALL OTHER TRADES.UNDER THE SINK BY 8".OVERLAP THIS CLEARANCE AREA.MAY OVERLAP THE FIXTURE'S CLEARANCE FIXTURES. (C.F.C.I.). SEE ADA MOUNTING HEIGHTS#4A1051-1/2"H. A.F.F.MOUNT TOP OF DISPENSER AT 30" AFF. I.G.C. AND ALL SUB-CONTRACTORS PERFORMI F.O.F.C.I. = OWNER FURNISHEJ.FIXTURES SHALL NOT OVERLAP INTO AREAS OF OTHER FIXTURE'S CLEARANCES.L.TOILET CLEARANCE AREA REQUIRED SHALL BE 5'-0"w. x 5'-6"D. THE TOILET MAY A.SEE SHEET A000 FOR TYPICAL ADA MOUNTING HEIGHTS FOR ACCESSORIES.B.CONTRACTOR TO PROVIDE BLOCKING IN C.COORDINATE FLOOR DRAIN LOCATIONS WITH MEP.D.CENTER ALL TILE PATTERNS, LEAVING EQUAE.C.F.C.I. = CONTRACTOR FURNISHED, CONTRACTOR INSTALLED.G.O.F.O.I. = OWNER FURNISHED, OWNER INSTALLED.H.T.F.O.I. = TENANT FURNISHED, CONTRACTOR INSTALLED.K.SINK CLEARANCE SHALL BE 2'-6"W. x 4'-0"D., ALLOWING CLEARANCE AREA TO EXTENDN.60" TURNING RADIUS SHALL BE PROVIDED WITHIN THE RESTROOM. THE TURNING RADIUS M.SHOWER CLEARANCE AREA REQUIRED SHALL BE 3'-0" D x 4'-0" W. TOILET ROOM NOTES T1PROVIDE 36" LENGTH GRAB BAR. (C.F.C.I.)T2PROVIDE 42" LENGTH HORIZONTAL GRABT3INTEGRAL BOWL IN SURFACE.T4PROVIDE SANITARY NAPKIN DISPOSAL AND TOILET TISSUE DISPENSER. BRADLEYT5PROVIDE SOLID SURFACE COUNTERTOP, SS-1 WITH INTEGRATED BOWL. (C.F.C.I.)T6WALL MOUNTED MIRROR (24"x 36"), (C.F.C.I.) BRADLEY MODEL #781-2436T7PROVIDE TOILET, C.F.C.I. SEE MEP DRAWINGS.T8MINIMUM 60" TURNING RADIUS CLEARANCE.T9PROVIDE PAPER TOWEL DISPENSE (C.F.C.I.) MOUNT TOP OF DISPENSER ATT108" DIAMETER CUT IN SURFACE WIT11KOALA KARE BABY CHANGING STATION (MODEL KB200-00)T12FLOOR MOUNTED PARTITION WALLS. T13PROVIDE SURFACE MOUNTED TOILET TISSUE DISPENSER. BRADLEY 5A20 (C.F.C.I.)T14PROVIDE WALL MOUNTED SOAP DISPENSER. BRADLEY MODEL #6A00T15WASTE RECEPTICAL. BRADLEY MODEL #377 18" MIN38" -41" TOILET GRABBARS 0" 2'-10" MAX PAPER TOWELDISPENSER MAIN LEVEL 3'-3 7/8" 48" MAX. FIREEXTINGUISHERCABINET NOTE: MOUNT ALL NON-HANDICAPACCESSORIES ACCORDING TOMANUFACTURER'S RECOMMENDATIONS. 48" MAX. T11 12" = 1'-0" 4' - 4" SOAPDISPENSER ADA MOUNTING HEIGHTS SCALE: 2' - 6" T9 4 WASTE RECEPTACLE T14 T5 1' - 7" A B DIAPER DISPENSER ORSANITARY NAPKIN DISPENSER T6 2' - 0" 5 A9-1 6' - 0"11" T10 2' - 10" SURFACE 1/2" = 1'-0" REFLECTING TO T15 WOMENS RR INTERIOR ELEVATION SCALE: T6 7" 40" MAX. 2' - 0" 04 T14 T5 T9 T14T9 T10T11 1' - 7" T3T3 2 T14 7" 2 MIRROR T9 2' - 8"6"2' - 10" A9-1 40" MAX 5 A9-1 TUO PS OT T8 34" MAX. 104 154 SF ELECTRIC WATERCOOLER WOMENS RR 1/2" = 1'-0" 13' - 2" V.I.F. MAIN LEVEL ENLARGED RR PLAN SCALE: 1 T12 EQEQEQEQ T2 T7 T7 N T4 T7 5' - 0" PLAN NORTH T1 T13 05 5'-1"3'-5"3'-3" 2' - 11" 40" MAX T13 T1 2' - 8"6"2' - 10" T7 2' - 2"2' - 2" 7" T14 T9 5' - 0" T7T4 1' - 7" 6' - 0" T6 T2 2' - 0" 4" INTEGRAL SOLIDSURFACE BACKSPLASHEDGE OF WALLANGLE SUPPORTS PAINTEDTO MATCH WALL T15 T12 1 1/2" = 1'-0" 11"T10 2' - 10" ADA CASEWORK SCALE: 2'-10" 5 A9-1 2' - 0" T6 5 13' - 0" 103T5 1' - 7" 144 SF MENS RR T8 T14 T9 A9-1 1/2" = 1'-0"2'-0" 3' - 1" 3 4' - 4" MENS RR INTERIOR ELEVATION SCALE: T9 T14 3 T3T3 T5T9 T14T10T11 T11 5" B 5 3'-3 7/8" A9-1 1/2" OVERHANG 6' - 0" COVER EXPOSED PIPES BLOCKING AS REQUIRED SOLID SURFACE COUNTERTOP MAIN LEVEL 0" 12' - 5" DWG # SHEET # DWG # SHEET # DWG # SHEET # 3 I2-1 7 I2-2 6 I2-1 5 I2-1 2 I2-1 12 I2-2I2-2 1 I2-1 5 I2-2 3 I2-2 4 I2-2 8 I2-1 9 I2-1 DWG # SHEET # 6 I2-2 7 I2-2 DWG # SHEET # 3 I2-1 21 I2-1I2-1 DWG # SHEET #