Loading...
HomeMy WebLinkAboutIUH Dermatology_Permit Set CARMEL, IN 11590 N. MERIDIAN SUITE #450 & PIPING CONTRACTORS, INC.TANK DERMATOLOGY CLINIC REV DATE HEALTH P CT REVISIONS INDIANA UNIVERSITY REV # 8-18-2017 ISSUE DATE:M101 SHEET NO. 1/8" = 1'-0" HVAC PLAN 1 HVAC PLAN NOTES GENERAL HVAC NOTES TYPICAL VAV BOX DETAIL AIR INLET / OUTLET SCHEDULE EXHAUST FAN SCHEDULE TYPICAL FLEX DUCT TO SLOT DETAIL TYPICAL FLEX DUCT TO DIFFUSER DETAIL C:\\_Revit Projects\\Jones, Sean - 652\\05890-Albrecht, Ben\\05890-Ahlbrecht-Detail.rvt CARMEL, IN 11590 N. MERIDIAN SUITE #450 & PIPING CONTRACTORS, INC.TANK DERMATOLOGY CLINIC REV DATE HEALTH P T C REVISIONS INDIANA UNIVERSITY REV # 8-22-2017 P101 ISSUE DATE: SHEET NO. 1/8" = 1'-0" PLUMBING PLAN PLUMBING PLAN KEY NOTES: WATER HEATER DETAIL TYP PRIVATE TOILET ISOMETRIC TYP EXAM SINK ISOMETRIC PLUMBING FIXTURE SCHEDULE WATER HEATER SCHEDULE GENERAL PLUMBING NOTES C:\\_Revit Projects\\Jones, Sean - 652\\05890-Albrecht, Ben\\05890-Ahlbrecht-Detail.rvt 317-780-8350 | WWW.CBMCINC.COM BY IU Dermatology 5855 KOPETSKY DR | INDIANAPOLIS, IN 46217 8/21/17 DATE REVISIONS INTERIOR LAYOUT SJM NO SCALE:1/8"=1'-0" LIGHTING PLAN N.I.C. C C NEW WORK C CC CC C CC CC C C CCC SYLVANIA RT6 900 LUMEN (WITH CONTECH HOUSING) DescriptionLPEC24-LED-HO-WW2 HEAD EXIT-EMERGENCY UNIT 45.8 Lum. Watts14 -- 0.9000.900-- LLF 9514202 Lum. Lumens-- Arrangement SINGLESINGLESINGLE C LabelL1EM Qty 1715915 Symbol Luminaire Schedule NOTE: ASHREA 90.1 2007 REQUIRES A MINIMUM OF (1) LIGHT SWITCH OR CONTROL DEVICE PER ROOM 3/4" X 10'-0" COPPER CLADGROUND RODS. A SINGLE ELECTRODE THAT DOES NOTSPECIFIED IN NEC:250.52 (A)(4)250.52 (A)(5)250.52 (A)(6)250.52 (A)(7) HAVE A RESISTANCE TO GRD OFLESS THAN 25 OHMS SHALL BE AUGMENTEDBY ADDITIONAL ELECTRODE(S) AS TELEBOARD TYP BRANCH PANEL #6 Cu. GRD WM WATER METER JUMPER. WATER PIPE.ELECTRODE PER 250.52(A)(1) CONDUCTOR. 250.122 SIZE PER NEC EQUIPMENT BONDING JUMPERPER TABLE 250.122 GROUNDING ELECTRODE MDP MAIN GROUND BUS (MGB)IN ELECTRICAL ROOM. MAIN BONDING JUMPER NEUTRAL BAR SLEEVE ELECTRODE PER 250.52(A)(2) FOR PURPOSE GROUNDING ELECTRODECONDUCTOR. CONNECTION LISTED NON-METALLIC PROTECTIVE CONCRETE ENCASED ELECTRODE PER 250.52(A)(3) INCOMINGSERVICE SERVICE GROUNDING DETAIL NOT TO SCALE.NOT TO SCALE. RISER DIAGRAM 317-780-8350 | WWW.CBMCINC.COM BY IU Dermatology 5855 KOPETSKY DR | INDIANAPOLIS, IN 46217 8/21/17 DATE REVISIONS INTERIOR LAYOUT SJM NO 208 F F F 208 F 208 SCALE:1/8"=1'-0" POWER PLAN 208 F F 208 FF F N.I.C. F F NEW WORK 208 F F F F 208 F 208 GFI F GFI F F F F F GFI F 208 F F F 208 F F F F F F F F 208 208 F F 208 F F F F F F 208 F F F 208 F 208 F 208 F F F GFI 208 F 208 F F GFI GFI 208 HORN/STROBESTROBEFIRE ALARM DUPLEX OUTLET 110 VOLTDEDICATED CIRCUIT 110 VOLTDUPLEX OUTLET W/GROUND FAULT INTERRUPTER208 VOLT OUTLETVOICE/DATA OUTLETPULL STATION DGFI F F F ELECTRICAL LEGEND