HomeMy WebLinkAbout17060277.9THIS WILL NOT BE A REQUIRED EXIT ART CENTER U > EX EXHAUST 2l I1 k ;I GFCI GFCI GFCI RH-1 Q / \ Q / — EM LIGHT C— GAil. Ail FC1I u 1 GFCI E K V IPJT�I'= \\ Q ELECTRICAL LEGEND SWITC3: ©-WAY SWITCHO MA D: DIMMER SWITCH @ 48" A.F.F. U.N.O. M: MOTION/OCCUPANCY SENSOR (U) SPECIFICATION GRADE 120V 3 -PRONG DUPLEX OUTLET z GFCI= OND. FAULT CIRCUIT INTERRUPT WP= WATERPROOF GFCI ENCLOSURE 240/208 V. OUTLET Q HALF -SWITCHED DUPLEX OUTLET. INSTALL WITH GROUND PRONG FACING UP, AND WIRE BOTTOM OUTLET TO SWITCH w N PHONE/DATA OUTLET: BOX & EMPTY CONDUIT TO ABOVE CEILING, CABLE BY OWNER D 0 J PHONE OUTLET W/ CONDUIT BACK TO PHONE Q BOARD OR I.T. ROOM TV CABLE OUTLET LOCATION W/BOX & EMPTY © CONDUIT TO ABOVE CEILING, CABLE BY OWNED SMOKE DETECTOR. DETECTOR SHALL SOUND SD ALARM AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING UNIT IN WHICH THEY ARE LOCATED. <FA> FIRE ALARM STATION @ 48" AFF U.N.O. 7 ELECTRIC MOTOR WIRED ELECTRICAL CONNECTION W/ DISCONNECT WIRED ELECTRICAL CONNECTION/ J -BOX Q PANEL BOARD ELECTRICAL NOTES 1. ALL WORK SHALL COMPLY WITH THE CURRENT INDIANA GAR AND ALL CODES APPLICABLE TO THIS PROJECT INCLUDING, BUT NOT LIMITED TO, THE 2009 IEC (2008 NEPA-70), THE NATIONAL FIRE ALARM CODE (NEPA-72), THE 2010 IECC (ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS), 2010 ADA STANDARDS, ICC/ANSI A117.1-2003, AND ALL OTHER APPLICABLE STATE & LOCAL STANDARDS & REGULATIONS. REPORT ANY CONFLICTS BETWEEN THESE CODES & REGULATIONS AND THE WORK INDICATED TO THE ARCHITECT/ENGINEER AT AWARD OF CONTRACT. 2. A COMCHECK REPORT HAS BEEN PREPARED FOR THIS PROJECT AND IS AVAILABLE FROM THE GENERAL CONTRACTOR. ALL SUBCONTRACTORS ARE EXPECTED TO OBTAIN A COPY AND COMPLY WITH THE REQUIREMENTS THEREIN. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE COMPLETION AND OPERATIONS OF ALL SYSTEMS IN THIS SECTION OF WORK. 4. SUBMIT LIGHT FIXTURE PRODUCT DATA FOR APPROVAL PRIOR TO PURCHASE. ALLOW AT LEAST (2) WEEKS FOR APPROVAL PROCESS AFTER SUBMITTAL. 5. COORDINATE ELECTRICAL WORK WITH OTHER TRADES TO AVOID CONFLICTS. COORDINATION MUST OCCUR PRIOR TO PURCHASING OR INSTALLING EQUIPMENT AND MATERIALS. 6. ALL EXTERIOR LIGHTING TO BE CONTROLLED BY TIMER AND PHOTOCELL. 7. ALL LIGHTING BALLAST SHALL BE ELECTRONIC. 8. ALL CONDUCTORS SHALL BE COPPER. 9. SIZE ALL CIRCUITS AND FEEDERS FOR LOADS AND LENGTHS. DO NOT EXCEED A 3% VOLTAGE DROP. 10. INSTALL EMT CONDUIT IN ALL OPEN AREAS AND WHERE EXPOSED. 11. LABEL ALL DISTRIBUTION EQUIPMENT, PANELS, DISCONNECTS, AND CIRCUITS. 12. INSTALL DUAL TECHNOLOGY OCCUPANCY SENSORS IN RESTROOMS TO COMPLY WITH REQUIREMENTS FOR AUTOMATIC SHUT-OFF OF EXHAUST FANS WHICH ARE SWITCHED WITH LIGHTS. GFCI GFCI Q — — — — — — — — — — \ \ RH-1 INTAKE Q E14FIRE / STROBE/HOkN 14 -TING F C I THIS WILL NOT BE A REQUIRED EXIT FA ACTIVITY CENTER \ Q EM LIGHT G ZtE I L DEMO 9 EXISTING WALL PACKS RETURN TO OWNER DEMO 2 EXISTING W/P RECEPTACLES EXTEND FIRE SPRINKLER SYSTEM INTO THESE NEW AREAS EXHAUST � I O IWEID RELOCATED LED WALL PACK LIGHT 4 EXIT ,KEX LIGHT m RE PIULLC>0 GFCI @1 MECHANICAL/ELECTRICAL FLOOR PLAN SCAL1E_--114"=1'-0" w O LL Lu m W 0 a F- w z V W a � (9IllielielleW Z (J) --� v W Q = a v a iiiiiiiiiiiie � N 9200 W. SMITH S- YORKTOWN, INDIAf TELEPHONE, 765 - FAX 765 - WEB usarchitectsn JERRY G. HOFFMA PARTNER KEITH L. GARY, PARTNER DRAWN: CHECKED ........._.....; ................................. REVISION W CD PHA a START DATE FINISH DATE PLOT INFORMA FILE NAME: K170C PLOTDATE: 5/12/ CAD 'OPER.: KAF SEAL H�L,,,I AGI STER9 �t No. AR0087012 STATE OF /ND W0- ,, q9.•.......... '' H M E