HomeMy WebLinkAbout17090012.6I
2
WORK 1AE-n mc -OLA
3
4
Solid surface tops included
Solid surface tops NOT included
5
NEW FLOOR PLAN
1/S"' = 1'-O"
NORTH
6
7
GENERAL NOTES:
1. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, JOB
CONDITIONS, ETC.
2. ALL DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS
NOTED OTHERWISE
3. SEE WALL TYPES, DOORS AND HARDWARE SCHEDULES FOR ADDITIONAL INFORMATION.
4. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHALL DO SO UNDER THE CENTERLINE OF
THE DOOR, UNLESS OTHERWISE NOTED.
5. HINGE SIDE OF DOOR JAMBS IN METAL STUD WALLS SHALL TYPICALLY BE LOCATED 4"
FROM ADJACENT WALL UNLESS OTHERWISE NOTED. SEE TYPICAL DETAILS ON SHEET A140
FOR ADDITIONAL INFORMATION.
6. PROVIDE BLOCKING IN NEW METAL STUD WALLS FOR ALL WALL SUPPORTED ITEMS. SEE
PLANS FOR CASEWORK LOCATIONS. A
7. PROVIDE FIRE STOPPING AT PENETRATIONS OF ALL RATED WALLS AND TENANT DEMISING
WALLS.
8. SEE REFLECTED CEILING PLANS FOR BULKHEAD LOCATIONS AND ASSOCIATED DETAIL
REFERENCES.
9. ALL MATERIALS TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS & STANDARD
SPECIFICATIONS.
10. REFER TO ROOM FINISH SCHEDULE FOR ALL REQUIRED FINISH INFORMATION.
11. REFER TO DOOR SCHEDULE FOR ALL DOOR AND FRAME TYPES, HARDWARE INFORMATION
AND ALL OTHER DOOR INFO.
12. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTING EXISTING
CONSTRUCTION, ALIGN FACE OF NEW CONSTRUCTION WITH FACE OF EXISTING CONSTRUCTION.
13. PROVIDE CONTROL JOINTS IN ALL RUNS OF GYP. BD. WALLS OVER 30 FEET IN LENGTH.
COORDINATE WITH DESIGNER PRIOR TO INSTALLATION FOR COMPLIANCE WITH DESIGN INTENT.
ALIGN CONTROL JOINTS W/ THE EDGE OF DOORFRAMES AT ALL POSSIBLE LOCATIONS.
14. ALL INTERIOR WALLS TO BE WALL TYPE 'A' UNLESS OTHERWISE NOTED. SEE SHEET A150
FOR ADDITIONAL INFORMATION.
15. AT ANY EXISTING RECEPTACLES WITHOUT COVER PLATE, PROVIDE COVER PLATE.
16. TOUCH UP ALL EXISTING FINISHES AS REQUIRED.
17. PROVIDE METAL CORNER BEAD AT ALL EXISTING GYPSUM BOARD HEADS, JAMBS, AND SILLS
WITH LEVEL 4 DRYWALL FINISH TO 3" ABOVE FINISHED CEILING LINE AT ALL EXISTING
PERIMETER EXTERIOR WALLS. TYP.
18. PROVIDE MIN. 4" GYPSUM BOARD OVER EXISTING STUDS ABOVE CEILING AT EXTERIOR WALLS
(WHERE FIBERGLASS INSULATION IS PRESENT), TYPICAL. TAPING AND FINISHING IS NOT
REQUIRED.
PLAN KEY NOTES: 1 13
OALIGN NEW WALL WITH EDGE OF GYPSUM BOARD SILL AT EXTERIOR STOREFRONT WINDOW
SYSTEM.
OPROVIDE GYP. BD. OPENING. SEE A600 SERIES.
OPROVIDE WATER LINE W/SHUTOFF VALVE FOR TENANT PROVIDED REFRIGERATOR AND/OR
ICEMAKER W/WATER PURIFICATION SYSTEM. LOCATE WATER SHUT—OFF VALVE IN OATEY 12K
OUTLET BOX IN WALL ® 48" AFF. SEE MEP DOCUMENTS.
OALIGN NEW WALL WITH EDGE OF EXISTING WALL CONSTRUCTION.
OPROVIDE 5/8" TYPE "X" GYP. BD. WALL FINISH AT EXISTING UNFINISHED METAL STUD WALL
CONSTRUCTION. PROVIDE LEVEL 4 FINISH AND PAINT ACCORDING TO FINISH SCHEDULE, TYP.
OPROVIDE COAT ROD AND SHELF PER DETAIL 5D/A150. FINISH PL -2. PROVIDE BLOCKING IN
PARTITION.
OPROVIDE WALL MOUNTED MELAMINE SHELVES ON HEAVY DUTY KV BRACKETS & STANDARDS C9
15" O.C. PROVIDE SHELVES 12"D (U.N.O.) x LENGTH NOTED. PROVIDE FIRE RETARDANT
TREATED WOOD BLOCKING IN WALL FOR STANDARDS. SEE DETAIL 1 B/A750. AT EXISTING
WALLS REMOVE & REPLACE DRYWALL TO FACILITATE BLOCKING INSTALLATION.
OPROVIDE ROUGH—IN FOR CARD KEY ENTRY SYSTEM. SEE DOOR SCHEDULE A140 FOR MORE
INFORMATION. COORDINATE W/ OWNER & TENANT'S VENDOR.
OPROVIDE NEW TRANSACTION COUNTER (WITHOUT SLIDING WINDOW) AT OPENING IN WALL. SEE
DETAILS.
ALIGN NEW WALL AT WINDOW MULLION. FINISH END WALL WITH ANODIZED ALUMINUM BRAKE
1 METAL CHANNEL W/ EDGES RETURNED. FINISH TO MATCH MULLION. SEE DETAIL 7E/A150.
PROVIDE SELF—RIMMING STAINLESS STEEL SINK AT CASEWORK WITH HOT & COLD WATER
11 SUPPLY AND DRAIN. PROVIDE PAPER TOWEL DISPENSER BOBRICK B-262 AND SOAP
DISPENSER AT ALL SINKS. ALL SINKS TO HAVE WRIST BLADE HANDLES AND GOOSE NECK
FAUCET WITH AERATOR.
12 PROVIDE BUILT—IN CASEWORK BENCH WITH 3' WALL CABINET ABOVE. VERTICAL FINISH PL -1,
HORIZONTAL FINISH PL -2. SEE DETAIL 6C/A750 & 6D/A751.
13 PROVIDE CASEWORK. SEE A600 SERIES.
PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING IN PARTITION FOR SUPPORT OF
14 OWNER—PROVIDED FLAT SCREEN MONITOR(S). PROVIDE DATA, N & ELECTRICAL CONNECTIONS,
PER MANUFACTURER'S REQUIREMENTS, FOR MONITORS. COORDINATE LOCATIONS WITH OWNER.
15 PROVIDE SURFACE APPLIED MECHOSHADE MANUAL THERMOVIEL VERTICAL WINDOW BLINDS AT
ALL EXTERIOR WINDOWS, ANCHORED INTO DRYWALL AT HEAD OF WINDOW OPENING.
16 PROVIDE JL INDUSTRIES AMBASSADOR MODEL 10171`10 SEMI—RECESSED FIRE EXTINGUISHER
CABINET AND FIRE EXTINGUISHER WHERE INDICATED, TO MEET STATE FIRE CODES.
COORDINATE LOCATION WITH LIFE SAFETY PLAN. 10LB. SEE DETAIL 5E/A150.
17 PROVIDE WORKSURFACE, TYP, AT THIS LOCATION AS SHOWN. SEE DETAIL 6E/A750.
18 PROVIDE NEW FULL—HEIGHT CASEWORK. SEE CASEWORK DWGS.
1 g PROVIDE BUILDING STANDARD METAL HORIZONTAL BLINDS.
20 PROVIDE FAUCET WITH INTEGRATED EYEWASH ON THIS SINK.
21 PROVIDE WALL—MOUNTED PORCELAIN SINK AT CASEWORK WITH HOT & COLD WATER SUPPLY
AND DRAIN. PROVIDE PAPER TOWEL DISPENSER BOBRICK B-262 AND SOAP DISPENSER AT
ALL SINKS. ALL WALL—MOUNTED SINKS TO HAVE FOOT PEDAL ACTIVATION WITH GOOSE NECK
FAUCET AND AERATOR.
22 PROVIDE WALL INFILL AT LOCATION SHOWN, TO MATCH CONSTRUCTION OF EXISTING ADJACENT
WALL CONSTRUCTION. PROVIDE LEVEL 4 DRYWALL FINISH AND FINAL WALL FINISH (PAINT
AND/OR VINYL WALL COVERING) TO MATCH EXISTING ADJACENT WALL SURFACES, TYP.
23 PROVIDE NEW INTERIOR H.M WINDOW FRAME AND J" TEMPERED GLASS, TYPICAL. SEE
INTERIOR ELEVATIONS FOR SIZES AND LOCATION IN WALL.
PROVIDE ELECTRICAL, DATA, & MONITOR AT MEDICAL REFRIGERATOR LOCATION.
KEYPLAN
N.T.S.
C
D
E
STUDIO
THREE
DESIGN
architecture — in
www.studio3design.r
317 595.1000 main 317 57,
8604 Allisonville Road, Suite 330 Indianapc
Indiana University
v�
}
L vt
}
Z
}
W .
1 (,
Z r (
Z w
I
PRO) ECT N O .
17029
DATE
08/09/17
CERTIFICATION
`\`\\aa►uuw uuuui�p�
�HYWC
0.
910110
STATE OF j
C H I T E�
°�'A�nnumninina ��\\
REVIS10NS
5H EET DESC RI PTI
NEW FLOOR PLS
SHEET NUMBER
Al 0(
THIS DRAWING IS THE PRO
OF STUDIO 3 DESIGN, IN