Loading...
HomeMy WebLinkAbout17090012.8I �� MED. DERM AAFn nFRM 3 !" I NEW REFLECTED CEILING PLAN 1/8" = 1'-0" NORTH 6 7 GEN ERALNOTES: 1. COORDINATE WITH MEP DESGIN/BUILD PLANS FOR ALL LIGHTING AND DIFFUSER LOCATIONS. REFLECTED CEILING KEYNOTES: OA NEW CEILING GRID, TILES, LED 2'x2' LIGHTING FIXTURES, HVAC, DIFFUSERS/RETURNS. SEE MEP DRAWINGS. ANGLE GRID AS SHOWN. CENTER GRID INSIDE EACH ROOM. ©TYPICAL BULKHEAD. (SEE DETAIL 3E/A150.) PAINT BULKHEAD TO MATCH ADJACENT WALL U.O.N. ©TYPICAL BULKHEAD. (SEE DETAIL 3D/A150.) PAINT BULKHEAD TO MATCH ADJACENT WALL. U.O.N. O NOT USED. O NOT USED. PROVIDE NEW RECESSED LED 10" CAN LIGHT FIXTURE. LOCATE PER MEP O DESIGN/BUILD DWGS. OG PROVIDE NEW RECESSED LED 6" CAN LIGHT FIXTURE. LOCATE PER MEP DESIGN/BUILD DWGS. O PROVIDE NEW SCONCE, TECH LIGHTING, DOBSON WALL, WHITE ASH. PROVIDE ABOVE CEILING STRUCTURAL SUPPORT & ALL RELATED CONNECTIONS JO FOR SINGLE/DOUBLE HEAD EXAM LIGHT AS SHOWN. SEE DETAIL 1 E/A150 FOR ABOVE CEILING STRUCTURAL SUPPORT. REFLECTED CEILING LEGEND: LCEILING TYPE MATERIAL/DETAIL VARIATION CEILING HEIGHT CLGt o' -o" 2' X 2' ACOUSTICAL CEILING TILE cLc2 0'-0' GYP. BOARD CEILING OR BULKHEAD CLG3 0'-0" OPEN TO DECK xisT o' -o" EXISTING CEILING TO REMAIN EXISTING CEILING GRID NEW CEILING GRID r 2' X 4' RECESSED FLUORESCENT ® 2' X 2' RECESSED FLUORESCENT MEP DESIGN BUILD: O RECESSED LIGHT PENDANT LIGHT 04 WALL MOUNTED SCONCE 0 EXHAUST FAN WALL MOUNTED EXIT SIGN ® CEILING MOUNTED EXIT SIGN 0 IL S 20A, SINGLE POLE SWITCH S. 20A, 3 -WAY SWITCH C QS PROVIDE BLOCKING FOR ROUND CEILING MOUNTED SPEAKERS ® HVAC SUPPLY DIFFUSER 17 HVAC RETURN GRILLE SD SMOKE DETECTOR 1. GENERAL CONTRACTOR SHALL COORDINATE ALL TRADES, INCLUDING DESIGN BUILD CONTRACTORS, AND ENSURE MEP SUBCONTRACTORS MEET WITH OWNER, DESIGNER, & OTHERS TO ENGINEER SYSTEMS TO MEET THE OWNER'S NEEDS. 2. GENERAL CONTRACTOR SHALL PROVIDE MEP DESIGN DOCUMENTS & DRAWINGS TO OWNER & DESIGNER FOR REVIEW, COMMENT, AND APPROVAL. 3. GENERAL CONTRACTOR SHALL ENSURE MEP DESIGN BUILD DOCUMENTS ARE SUBMITTED TO THE STATE & LOCAL CODE OFFICIAL AS REQUIRED BY STATE STATUE/LAW. 4. HVAC SYSTEMS TO BE VENDOR ENGINEERED UNDER SEPARATE CONTRACT. 5. ELECTRICAL POWER & DATA SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPARATE CONTRACT. 6. LIGHTING SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPARATE CONTRACT. 7. PLUMBING SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPARATE CONTRACT. 8. G.C. IS RESPONSIBLE TO PROVIDE ALL COORDINATION OF DESIGN & CONSTRUCTION DISCIPLINES. 9. G.C. IS RESPONSIBLE TO PROVIDE ALL DESIGN, MATERIAL AND LABOR UNDER SEPARATE VENDOR CONTRACT AS REQUIRED FOR A COMPLETE INSTALLATION IN COMPLIANCE WITH ALL STATE, LOCAL AND HEALTH DEPARTMENT BUILDING CODES. 10. ARCHITECTURAL DOCUMENTS PROVIDE SUGGESTED LIGHTING LOCATIONS & FIXTURE TYPES. ALL CIRCUITING TO BE VENDOR ENGINEERED BY CONTRACTOR. 11. ELECTRICIAN &/OR DESIGN BUILD CONTRACTOR TO VERIFY THAT PROJECT CRITERIA MEETS 2010 INDIANA ASHRAE 90.1-2007 WITH INDIANA AMENDMENTS ENERGY CODES. DESIGN INTENT IS TO BE WITHIN WATTS PER SQUARE FOOT. PROVIDE ENERGY MANAGEMENT CONTROLS, SUCH AS SENSOR CONTROLS (ULTRASONIC & MOTION DETECTION) AND/OR RELAY TIME CLOCKS, AS REQUIRED BY THE CODE. KEYPLAN N.T.S. I I I I 0 E THIS DRAWI NC IS THE PROPERT OF ST-UDI0 3 DESIGN, INC., u STUDIO THREE DESIGN -architecture M interior www.studio3design.net 317 595.1000 main 317 572.1231 8604 Allisonville Road, Suite 330 Indianapolis, IN Indiana University He v o Ln Z LLJ w U �� < w wC)� -- z _ WC) < w � C < < r< O t ' , ON W Ln r PRO) ECT NO. 17029 DATE 08/09/17 CERTI FICATI0N o�NY W'Co No. ,r *, 910110 i*= STATE OF i ND}ANP�l '7 HITEG srrs REVISIONS SHEET DESCRI PTION NEW REFLECTED CEILING PLAN SHEET NUMBER A120 THIS DRAWI NC IS THE PROPERT OF ST-UDI0 3 DESIGN, INC.,