HomeMy WebLinkAbout17090012.101
3 5/8", 20 GA. MTL.
STUDS W/ 5/8"
GYP. BD. EA. SIDE
SINGLE CSE STUD
3 5/8"W x 2 1/2"D
16GAUGE, FLOOR TO
DECK. (OPTION, SUB-
STITUTE DOUBLE STUD,
18 GA., AT JAMB IN
PLACE OF CSE STUD).
SEALANT EACH
SIDE
HOLLOW MTL.
DOOR FRAME
JAMB ANCHORS
(3) PER JAMB
DOOR AS
SCHEDULED
DOOR JAMB, TYP.
L 4 7/8-
-4-
C14
/8 L
/8", 20 GA. MTL.
DS W/ 5/8"
BD. EA. SIDE
16 GA. BOX HEADER
BETWEEN JAMB STUDS.
SEALANT EACH
SIDE
7'-2" AFF Q�
P OF FRAME
HOLLOW MTL.
DOOR FRAME
DOOR AS
SCHEDULED
6"
DOOR H EAP, TYP.
3 "=1'-0"
1/4"
TEMPERED
GLASS
II
I
KICK PLATE
WHERE
SCHEDULED
FLUSH
SCW
4" I.I. X10"
in
a
Q
0
w
Of
� o
1.1
FLUSH SCW
W/ LITE
(4" X 25" LITE)
DOOR TYPES
1/4"=1'-0"
DECK
NOTE: JAMB
ANCHOR CLIPS,
SHOP WELD TO
FRAME. SCREW
OR BOLT TO
MTL. STUDS.
C
Scw w/
LITE
DOOR FRAMING, TYP.
140,/ 1/4"=V-0"
4 7/8"
'8", 20 GA. MTL.
S W/ 5/8"
BD. EA. SIDE
BARN DOOR
AS SCHEDULED
BARN DOOR JAMB
L 4 7/8-
6 "
/8"
/4"
EMPERED
LASS
ROSTED FILM
,NOD.
LUM.
COR
SCW= SOLID CORE WOOD
HM= HOLLOW METAL
ALUM= ALUMINUM
HCW= HOLLOW CORE WOOD
PROVIDE BOX HEADER BETWEEN
STUDS TO DECK, TYP.
CSE STUD, 16 GAUGE. MATCH
WIDTH OF WALL FRAMING, EACH
SIDE OF DOOR, FLOOR TO DECK.
6" WIDE FLAT MTL. STRAP. 18 GA.
CENTERED AT STRIKE AND HINGE
POINTS, TIED TO ADJACENT STUD.
FLOOR ANCHOR CLIPS
SECURED W/ NO LESS THAN
TWO SUITABLE FASTENERS
3 5/8" 20 GA. MTL.
STUDS W/ 5/8"
GYP. BD. EA. SIDE
BARN DOOR
HARDWARE
STAINLESS
STEEL WHEELS
STAINLESS
STEEL TRACK
7'-0" AFF
TOP OF FRAME
BARN DOOR
AS SCHEDULED
BARN DOOR HEAD
3"=1'-0"
WALL STOP (ALIGN WITH DOOR
LEVERSET IN NEUTRAL POSITION)
TYP. WALL STOP
N
2"
ww
N
VARIES
SEE DOOR
SCH. FOR SIZE
Lj, 2" 2" VARIES 2" -2"
SEE DOOR
SCH. FOR SIZE
2"
N
N
NO.
LOCATION
Cn
ELEV
MAT'L
N
ELEV
MAT'L
,r,r
0
SILL
HEAD
0
HARDWARE
DOOR RATIN G
REMARKS
400A
WAITING
3'-6" X 7'-0"
C
V)
O
==w
F1
1/4"
NQ
--
Q
1 B/A140
1
TEMPERED
>
400B
>
fy-GLASS
0
C
GLASS
0
F1
HM
0
0
--
1 C/A140
0
0
4
--
w
401A
MED. DERM EXAM
w
N
A
SCW
C
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
FULLY WELDED
402A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
HOLLOW METAL
F1
HM
P-2
--
F1
FRAME. (TYP.) F2
4
--
DOOR FRAMES
14 1/4"=1'-0"
4
DOOR SCHEDULE
DOOR
FRAME
= MATCH EXISTING
WD
= WOOD
NO.
LOCATION
SIZE
ELEV
MAT'L
FINISH
ELEV
MAT'L
FINISH
SILL
HEAD
JAMB
HARDWARE
DOOR RATIN G
REMARKS
400A
WAITING
3'-6" X 7'-0"
C
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
1
--
2,3,4,6
400B
WAITING
3'-0" X 7'-0"
C
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
2
401A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
402A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
403A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1C/A1 40
1 B/A140
4
--
404A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
405A
WORK ROOM
4'-6" X 7'-0"
A
SCW
ST
--
HM
--
--
2C/A140
2B/A140
6
--
406A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
407A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
408A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
409A
WORK ROOM
4'-6" X 7'-0"
A
SCW
ST
--
HM
--
--
2C/A140
2B/A140
6
--
410A
SOILED HOLD
4'-6" X 7'-0"
A
SCW
ST
--
HM
--
--
2C/A140
2B/A140
6
--
411A
WORK ROOM
4'-6" X 7'-0"
A
SCW
ST
--
HM
--
--
2C/A140
2B/A140
6
--
412A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
413A
PATIENT RESTROOM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
5
--
414A
STORAGE
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
3
--
415A
REGISTRATION
3'-0" X 7'-0"
B
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
416A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1C/A140
18/A140
4
--
417A
MED. DERM EXAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
113/A140
4
--
5
418A
UVB/BLU-U
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
419A
EXCIMER LASER
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
420A
V -BEAM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
421A
WORK ROOM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
422A
MED. DERM SURGICAL
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
423A
MED. DERM SURGICAL
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
424A
MED. DERM SURGICAL
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
425A
NURSE MGR
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
426A
BREAK ROOM
3'-0" X 7'-0"
B
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
2
427A
PHYS. WORK ROOM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
428A
TRIAGE
3'-0" X 7'-0"
B
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
429A
STAFF RESTROOM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
5
--
430A
STORAGE
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
3
--
431A
WHITE COAT
4'-6" X 7'-0"
A
SCW
ST
--
HM
--
--
2C/A140
2B/A140
6
--
432A
SOILED/1310
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
3
--
2
434A
MOHS
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
435A
MOHS
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
436A
MOHS
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
437A
MOHS
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
8
438A
LAB
3'-0" X 7'-0"
B
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
2
439A
MOHS STORAGE
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
3
--
440A
MED
PAIR 2'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
3
441A
MOHS WAITING
3'-0" X 7'-0"
B
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
442A
PATIENT RESTROOM
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
5
--
443A
LASER
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
444A
LASER
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
445A
STORAGE
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
3
--
446A
LASER
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
447A
RN/MA
3'-0" X 7'-0"
B
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
5
448A
PATIENT RESTROOM
3'-6" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1B/Al 40
5
--
4
449A
COMESTIC AESTH
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
450A
COMESTIC AESTH
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
451A
OFFICE
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
452A
MIXING STORAGE
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
3
--
3
453A
LASER
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
454A
LASER
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
455A
LASER
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
456A
LASER
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
457A
PHOTO
4'-6" X 7'-0"
A
SCW
ST
--
HM
2C/A140
2B/A140
6
--
458A
SURGICAL
3'-6" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
2
--
4, 5, 8
459A
REGISTRATION
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
461A
WAITING
3'-6" X 7'-0"
C
SCW
ST
F1
HM
P-2
--
1 C/A14C
1 B/A140
1
--
2, 3, 41 6
461B
WAITING
3'-6" X 7'-0"
C
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
4
--
2
484A
CORRIDOR
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
1
--
3
490A
CORRIDOR
3'-0" X 7'-0"
A
SCW
ST
F1
HM
P-2
--
1 C/A140
1 B/A140
1
--
3
7
GENERAL DOOR NOTES:
1. DOOR PANEL THICKNESS TO BE 1 3/4" TYPICAL FOR ALL SCW
DOORS.
2. PROVIDE WALL STOPS AT ALL DOORS. PROVIDE OVERHEAD STOP
AT LOCATIONS WITHOUT AN ADJACENT PERPENDICULAR WALL.
3. GENERAL HARDWARE NOTES:
A. COORDINATE HARDWARE WITH LANDLORD'S BUILDING
STANDARDS.
B. ALL DOOR HANDLES TO BE "LEVER" TYPE.
C. HARDWARE FINISHES TO BE US26D, DULL CHROME, TYPICAL.
D. ALL KEYING FOR LOCK SETS TO BE COORDINATED WITH
TENANT AND SHALL BE CAPABLE OF ACCEPTING BEST
CORES.
E. ALL TRIM SHALL MATCH EXISTING IN USE.
4. WOOD SPECIES SHALL MATCH ALGOMA PLAIN SLICED CHERRY
RA -1052.
5. PAINT ALL H.M. DOOR FRAMES P-6.
DOOR HARDWARE:
SET 1: SUITE ENTRY LOCKSET
1.5 PR BALL BEARING HINGES
1 SUITE LOCKSET
1 WALL STOP.
1 CLOSER.
SET 2: OFFICE LOCKSET
1.5 PAIR BALL BEARING HINGES
1 OFFICE LOCKSET.
1 WALL STOP.
SET 3: STORAGE ROOM SET.
1.5 PAIR BALL BEARING HINGES
1 STORAGE LOCKSET.
1 WALL STOP.
1 CLOSER.
SET 4: LATCH/PASSAGE SET
1.5 PR BALL BEARING HINGES.
1 LATCH/PASSAGE HARDWARE SET
1 WALL STOP.
SET 5: PRIVACY LOCKSET
1.5 PR BALL BEARING HINGES
1 PUSH BUTTON PRIVACY LOCKSET
1 PRIVACY WITH COIN TURN
1 WALL STOP.
ABBREVIATIONS:
ETR
= EXISTING TO REMAIN
ME
= MATCH EXISTING
WD
= WOOD
HM
= HOLLOW METAL
PTD
= PAINTED
ST
= STAIN
EFR
= EXISTING FRAME REUSED
EDR
= EXISTING DOOR REUSED
DOOR RE,%LARKS:
SET 6: BARN DOOR
1 BARN DOOR TRACK & HARDWARE
1 STOP IN TRACK
2 DOOR PULLS - 24" VERTICAL
BRUSHED ALUM.
1. PROVIDE ELECTRIC STRIKE AND PUSH-BUTTON DOOR
RELEASE ACCUATOR. LOCATE DOOR RELEASE ACCUATOR AT
REGISTRATION WORKSTATIONS.
2. PROVIDE CLOSER.
3. PROVIDE ELECTRIC STRIKE AND ROUGH -IN FOR CARD
READER TO BE INSTALLED UNDER SEPARATE CONTRACT.
4. PROVIDE CONTINUOUS GEARED HINGE AT DOORS LARGER
THAN 3'-0" W.
5. PROVIDE FLOOR STOP IN PLACE OF WALL STOP. DO NOT
INSTALL UNTIL TENANT VERIFIES EXACT LOCATION FOR
INSTALLATION.
6. PROVIDE STANLEY DOOR OPERATOR AND ACTUATOR PADS.
7. PROVIDE ELECTRIC STRIKE.
8. PROVIDE 18 GA. STAINLESS STEEL KICKPLATES ON BOTH
SIDES OF DOOR. KICKPLATES TO BE 2" NARROWER THAN
DOOR, CENTERED IN DOOR WIDTH, AS SHOWN IN ELEVATION
"A" IN 1 D/A140.
A
C
D
E
� tt tt
STUDIO
THREE
DESIGN
architecture M interior dE
www.studio3design.net
317 595.1000 main 317 572.1236
8604 Allisonville Road, Suite 330 Indianapolis, IN 41
Indiana University Hey
v o
Ln
Lij
� v
w
w L
C)
L
W
Z
w <
<
O
Nz
P IRO) ECT N O.
17029
DATE
08/09/17
CERTIFICATION
No.
=* 910110 '*=
STATE OF
H I T E�
,,,p,rminui�nu
...mss
REVISIONS
SH EET DESC RI PTI ON
DOOR SCHEDULE &
DETAILS
SHEET NUMBER
A14C
THIS DRAWING IS THE PROPER
OF STUDIO 3 DESIGN, INC.,
ALL RIGHTS RESERVED.