HomeMy WebLinkAbout17090012.23GENERAL PLUMBING NOTES 1. CONTRACTOR SHALL CONTACT AND COORDINATE WITH ALL APPLICABLE UTILITIES. 2. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND EXISTING UTILITY SERVICE LOCATIONS PRIOR TO COMMENCING WORK. NOTIFY CONSTRUCTION MANAGER OF ANY INCONSISTENCIES WITH THE PLANS AND 3. PLUMBING AND PIPING SYSTEMS SHALL BE INSTALLED COMPLETE PER ALL APPLICABLE STATE AND LOCAL CODES. ALL MATERIALS, FIXTURES, DEVICES SHALL BE SUBMITTED FOR APPROVAL TO ADMINISTRATIVE AUTHORITY AND SHALL CONFORM TO APPLICABLE STANDARDS AND BE FREE FROM DEFECTS PER INTERNATIONAL PLUMBING CODE (IPC) 301.1.1. TEST SYSTEM PER 2009 IPC SECTION 712.0 4. PROVIDE ALL REQUIRED WASTE, VENT, FLEX CONNECTIONS, GUAGES, SHUT-OFF VALVES, UNIONS AS REQUIRED FOR EACH FIXTURE TO MAKE A WORKING SYSTEM. 5. REFER TO ARCHITECTURAL AND SITE CIVIL DRAWINGS FOR EXACT LOCATIONS OF PIPING AND FIXTURES AND/OR ADDITIONAL PLUMBING DETAILS. DO NOT SCALE THESE DRAWINGS. 6. PIPE ROUTING IS DIAGRAMATIC. CONTRACTOR SHALL MAKE ROUTING CHANGES AS REQUIRED TO COORDINATE WITH OTHER TRADES. 7. ALL PIPE SIZES SHOWN ON DRAWINGS OR SCHEDULED ARE MINIMUM SIZES. 8. OVERHEAD PIPING SHALL BE HELD TIGHT TO UNDERSIDE OF STRUCTURAL MEMBERS EXCEPT WHEN IN CONFLICT WITH OTHER TRADES OR OTHERWISE NOTED ON THE PLANS. 9. SANITARY PIPING SHALL BE SCH. 40 PVC & PITCHED MINIMUM OF 1/8" PER FOOT. ABOVE GRADE STORM/SANITARY/VENT PIPING SHALL BE SCH. 40 PVC PIPE WITH ARMAFLEX FLAME SPREAD COVERING AS THEY PASS THRU RETURN AIR PLENUMS. COMPLY WITH ANSI/ASTM REQUIREMENTS WASTE, VENT, DRAIN PIPE SHALL COMPLY WITH IPC 701.0 TO 706.0 AND TABLE 14.1. 10. COMPLY WITH ALL ADA REQUIREMENTS. 11. PROVIDE WATER HAMMER ARRESTORS FOR EACH RESTROOM FIXTURE GROUP UPSTREAM OF LAST FIXTURE. 12. HOT AND COLD WATER PIPING ABOVE GRADE SHALL BE PER IPC 604.0 TO 609.0, AND TABLE 14.1 PIPING SIZED PER IPC 610.0 INSTALL PIPING SO THAT THE ENTIRE SYSTEM CAN BE DRAINED. INSTALL CHROME ESCUTCHEON PLATES AT ALL WALL/CABINET PENETRATIONS 13. ALL HOT AND COLD WATER PIPING LOCATED ABOVE CEILINGS, ON PERIMETER AND INTERIOR WALLS, AND EXPOSED SHALL BE INSULATED WITH RUBATEX. COLD WATER PIPE SIZE UP TO 2" THICKNESS 1/2". PIPE SIZE 2.5" AND LARGER THICKNESS 1". HOT WATER PIPE SIZE UP TO 2" THICKNESS 1". PIPE SIZE 2.5" AND LARGER THICKNESS 1-1/2". 14. ALL WATER HEATERS SHALL COMPLY WITH IPC SECTION 501.0 TO 506.0 AND TABLE 14.1. ANSI Z21 TANK CONSTRUCTION 15. TEST WATER SYSTEM UNDER 150 PSIG HYDROSTATIC PRESSURE FOR A MIN. OF 4 HOURS. 16. PROVIDE CLEANOUTS AT ENDS OF ALL HORZ. RUNS AND AT BASE OF VERTICAL WASTE STACKS. CLEANOUTS SAME SIZE AS PIPE THEY SERVE. PROVIDE SUITABLE WALL OR FLOOR CLEANOUT AND COVER APPROPRIATE FOR THE SUBSTRATE 17. ALL PLUMBING FIXTURES SHALL BE INSTALLED PER STATE CODE AND IPC 402 AND TABLE 4.1 FOR WATER CONSERVING FIXTURES AND FITTINGS. ALL FIXTURES SHALL COMPLY WITH IPC SECTION 401.0 TO 420.0 AND TABLE 14.1. 18. ALL PLUMBING SYSTEMS SHALL BE INSTALLED PER STATE & LOCAL CODES AND BE FREE OF LEAKS AND SHALL SUPPLY WATER AT SUFFICIENT PRESSURE TO OPERATE ALL FIXTURES DURING PEAK DEMAND. 19. ALL PUBLIC HAND WASH SINK SHALL COMPLY WITH 2012 IPC SECTION 416.5 TO HAVE THERMOSTATIC MIXING DEVICE ON HOT WATER. 20. PROVIDE RUBBER WATERLESS TRAP SEALER FOR ALL RESTROOM FLOOR DRAINS. PLUMBING FIXTURE SCHEDULE MARK TYPE MODEL MIN. WASTE MIN. VENT MIN. CW MIN. HW REMARKS MODEL CAPACITY OR EQUAL CONN. CONN. CONN. CONN. 4.5 KW T&P VALVE, 3/4" HW/CW CONN. ELEC ECL -50 50 240/1 TANK TYPE, ELONGATED BOWL, CHAMPION 4 P-1 H WATER CLOSET FLOOR MOUNT TANK AMERICAN STD 2" 1/2" -- CHURCH 295 SEAT (HDCP) 2002.014 3" FLOOD RIM HEIGHT 18" P -2H LAVATORY AMERICAN STD. 1/2" 1/2" DELTA FAUCET 2529-LGHDF-2HDL WALL HUNG 2" 1-1/2- OFFSET TRAP/ TRUEBRO TRAP INSUL.KIT (HDCP) 0355.012 P-2 LAVATORY WALL HUNG AMERICAN STD. 2" 1-1/2" 1/2" 1/2" DELTA FAUCET 2529-LGHDF-2HDL 0355.012 STAIN. ST. SINK DAYTON1/2" 15" X 15" STAINLESS SINK, 1 GPM AERATOR P-3 SINGLE CPT D11515 2" 1-1 /2" 1/2" ZURN Z831 B4 -XL GOOSENECK FAUCET COUNTERTOP STAIN. ST. SINK DAYTON25" X 22" STAINLESS SINK P-4 SINGLE COMPT D12522 2" 1-1/2" 1/2" 1/2' ZURN 283164 -XL GOOSENECK FAUCET COUNTERTOP STAIN. ST. SINK DAYTON33"X 22" STAINLESS, DOUBLE COMPARTMENT SINK P-5 DOUBLE COMPT 2" 1-1/2" 1/2- 1/2- PROVIDE VAC. BREAKER ON FAUCET COUNTERTOP D23322 DELTA 40OWF FAUCET, W SPRAY, 1 2HP GAR. DISP. WATER HEATER SCHEDULE GALLON HEATING MARK TYPE MODEL CAPACITY CAPACITY REMARKS WH -1 A.O.SMITH 4.5 KW T&P VALVE, 3/4" HW/CW CONN. ELEC ECL -50 50 240/1 HEAT TRAPS THERMOSTATIC MIXING VALVE 1" 1-1 /2"V. P3 2" SAN 1 TYP EXAM SINK ISOMETRIC P10t NO SCALE `2" 1 1/2"- P P2H 1 H C. 0. 2'-'- 4" ' 4" 2 TYP PRIVATE TOILET ISOMETRIC P101 NO SCALE .. MED: 0EN�; ZX IMER� E` / " LASER` j` 416 ' 419 P20 � CORRIDO -, 484 -_ :. DERM _ll WORK � EXAM P � 4a ROOM" 405 E RM P3 1 �;� i 0 / ° --- - -- 1 HW�,� P30 CORRIDOR ° P30 4-82 _ ®P30 i --� MEV�L- MED. DERM ` EXAM -;7 I \� MED. i WORK', EXA ROOM X 411 > \ CO IDOR P3 1 COR IDOR 48 - 4 3 MED. r r` s EXAM l> 412 v1E(7 �VERM EXAM SAT--/. ` S ILED � P3 -, P3 1 0 OLD 10 i WORK MED. nL"Dw, R I i > E' PIH /CORRIDOR UVB/ ` \ RE ;'7. BLU -U //� �� �� 418 �' = P3Q-__ C O R R RA01 ----- - ° STORAGE O ME DERM N0Rn RI 445 O P2 1 S�RGICAL �� PHYS. v P2 10 423 _ / ` 42' � ' D. D� J9 RG�CALr suaa P30 VEP.' DERM i X, SU �' P30 422 P3O ° / _,4SERf 444 NURSE/ �P4 10 /P300 CORRIDOR MGR ,"BAITING \� 461 P4 0 r 425TRIGE 490. S 428/, .�i SOILED/ .G 443 f _. BIO ,�A`ti i` /�< - a_ REGIST. CORRIDOR CORRID 432 �459 =4=87=f"\-- 486 STAFF I_- - - OH % , / PHOTO ; g, R /R �WHITE �` MA RN MA 457 BREAK RM 429 CO A 433 CORRIDOR 447 42 6 P2 489 '�!y 1 CORRI R LASE P5 0® /� STO RN MA ..��' ` 492 45 �!\ - 427 430 ` 1 SAT. ,�,� MfXING STOR \ P30 MOHS IT � y c \ P1 448 / 452 " ) WAIN � & i � '\\. PIH Alaw \� 2 ' y�SMf TI C , / PAT, , AESH 45 %r 449 �`yt34 P3 1 'r �42 0 / - �% MEG �� P3 10 CORRIDG P3 P �P1H (� 91 RA C 0co P30 P3 1 Q P30 i MOHS �. �� � OHS� � �,SME 'T- >,' 5 GAL. EXP. TANK AEST 435 STO.R GL �� P4(1>"r 450 A . - _ LA54R SUPPORT ON `Ji 439 :AB°� WALL, NOT PIPE HOT WATER 105° F / ,� �.' CORRI ��� ! �i D��K4fi� L - 1_ 1/ 2 48 s OFFICt r_ 2„ COLD WATER-- -- P3 BALC. 1/2" Ba 1. V. 34" -> VALVE / /r P30 HOT WATER RET. , PLUMBING PLAN 1 BALL VALVE / -0/ Q 1 _1�2'n _ 1 �_On V 1 /2" Y -STRAINER N O R T H T 1 " HOT WATER CIRCULATION PUMP 1 " B&G #NFB-22, 115 V, 0.8 AMPS GROUNDED PLUG CONNECTION AUTO TIMER CONTROL THERMOSTATIC MIXING VALVE (Locate below W.H. outlet) APPROVED ASSE 1070 MIXING VALVE AUTO TIMER CONTROL SET TMV FOR 105E OUTLET 3/4" FROM PRV TO MOP SINK 3 WATER HEATER DETAIL NO SCALE PLUMBING PLAN KEY NOTES: 1. 1/2" COLD(NEW) & 1/2" HOT WATER(NEW) DOWN TO NEW SINK FIXTURE PER SCHEDULE. TIE-IN 2" SANITARY & 1-1/2" VENT TO EXISTING. VERIFY CONNECTION LOCATION PRIOR TO INSTALLING NEW PIPING. 2. 1/2" COLD WATER DOWN TO FIXTURE FROM EXISTING CW MAIN. TIE-IN 3" SANITARY & 2" VENT TO EXISTING. VERIFY CONNECTION LOCATION PRIOR TO INSTALLING NEW PIPING. 3. SEE DETAIL THIS SHEET FOR NEW WATER HEATER. 4. EXISTING SANITARY -COLD WATER RISER 3::� 1" BAR ON ORIGINAL DRAWING 0 1"