HomeMy WebLinkAbout17080173.1M,
MECHANICAL &
GENERAL PROJECT NOTES
ELECTRICALNOTES
1.
ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING
19.
ENSURE THAT ALL MATERIALS AND LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY
CONSTRUCTION TYPE AS DEFINED BY SECTION 601 OF THE INDIANA BUILDING CODE.
STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL
1. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPES OF WORK ARE LIMITED TO
CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH
BASIC DESIGN -BUILD ALTERATIONS WHICH ARE OUTLINED IN THESE PLANS. THE
2.
ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND
ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL,
DESIGN -BUILD CONTRACTORS FOR EACH TRADE MUST NOTIFY THE ARCHITECT IF THEY
LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE
MECHANICAL, AND ELECTRICAL CONSTRUCTION.
FIND THAT THE SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTRICAL OR
CURRENT APPLICABLE BUILDING CODE(S) FOR THEIR RESPECTIVE SCOPE OF WORK.
PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT ANY NECESSARY
20.
ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY
ENGINEERING CAN OCCUR AND ADDITIONAL PLANS CAN BE FILED, OR IF ADDITIONAL
3.
CONTRACTOR(S) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT. THE
SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER.
INFORMATION IS NEEDED IN ORDER TO DO THE WORK IN THE FIELD. THE MECHANICAL,
DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS
ELECTRICAL AND PLUMBING DESIGN -BUILD CONTRACTORS SHALL COMPLY WITH ALL
OR NEW WORK REQUIREMENTS. CONTRACTOR(S) SHALL MAKE THEMSELVES FAMILIAR
21.
REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER
APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM
WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS
TRADES. FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY
SYSTEMS SHALL BE INSTALLED BY THE APPROPRIATE DESIGN -BUILD CONTRACTOR AND
OF THE SCOPE OF WORK.
CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER
MUST COMPLY WITH ALL APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE
DURING PRE-BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT.
SUPPRESSION AND FIRE ALARM DESIGN -BUILD CONTRACTORS ARE RESPONSIBLE FOR
4.
FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL
COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR PERMITS.
CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS
22.
FURNITURE, OFFICE EQUIPMENT, OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING
PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS.
MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT
2, MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE
NOTED DIMENSIONS TAKE PRECEDENCE.
ATTACHED TO THE BUILDING ARE FOR REFERENCE ONLY AND ARE NOT TO BE PROVIDED
DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING
AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED.
PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
5.
VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS
DISCREPANCY THROUGH THE GENERAL CONTRACTOR TO SCHOTT DESIGN, INC.
23.
REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF
WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION
ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST
6.
THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL
JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS.
COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
ON-SITE ACTIVITIES; SUCH AS, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS
STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL,
24.
PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH
3. VERIFY HEAT LOADS OF ANY SPECIAL EQUIPMENT IN THE TENANT SPACE, AND PROVIDE
AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE
DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE
ADDITIONAL AIR FLOW IF REQUIRED. CONFIRM WITH OWNER PRIOR TO ANY PURCHASE
CONTRACTOR SHALL ALSO COORDINATE WORK "BY OTHERS" WITH HIS/HER OWN
FOR FINISH.
OF NEW EQUIPMENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE
ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE.
25.
ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH
OFFICE SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING
OWNER/LANDLORD.
7.
THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING
THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS.
HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURING
4. RELOCATE AIR -SUPPLY DIFFUSERS AND RETURN -AIR GRILLES AS REQUIRED. PROVIDE
HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND
26.
EXECUTE A THOROUGH FINAL CLEAN AND INSPECTION OF THE SPACE UPON
PROPER AIR SUPPLY FOR DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES.
WEEKENDS WHEN THAT CONSTRUCTION IS DEEMED TO INTERFERE WITH THE OPERATIONS
COMPLETION OF THE PROJECT. ALL SURFACES, FIXTURES, AND EQUIPMENT SHALL BE
CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS
OF ADJACENT TENANTS.
CLEAN, AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT
REQUIRED BY CODE.
REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL
8.
FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL
CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK.
5. POSITION LOCATION OF ALL THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE
DESIGN. COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNITURE PANEL OR
OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER
27.
PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR
OTHER CONFLICTS.
FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE. THE OWNER, TENANT, OR
INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT.
DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE
6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE
CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES.
28.
ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM
DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF
BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE
ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF
9.
SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT
DRAWINGS. WRITTEN DIMENSIONS GOVERN.
THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL
PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH
APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY
29.
CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS.
PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES.
SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION.
REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING
STANDARD.
7. COMPLY WITH THE INDIANA ELECTRICAL AND MECHANICAL CODE AND ALL OTHER
10.
SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND
SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS,
30.
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS
APPLICABLE CODES.
SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR
REGARDING LOCAL PLAN REVIEW, PERMITS, INSPECTIONS, AND FEES. THE GENERAL
8. SIZE AND CIRCUIT ELECTRICAL POWER ITEMS. PROVIDE OR REUSE ELECTRICAL POWER
MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AND THE PUBLIC AT ALL TIMES.
CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND
AND DATA OUTLETS AS REQUIRED.
SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT
11.
THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP
DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL
9. ALL ELECTRICAL OUTLETS WITHIN 6-0" OF WATER ARE TO BE G.F.C.I.
PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO
CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR
CONDUCT BUSINESS IN A SAFE AND CLEAN ENVIRONMENT.
AGREEMENT.
10. AT EACH PHONE AND DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO
BOX. TENANT'S DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND
12.
THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR
31.
FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH
PROVIDING APPROPRIATE TERMINALS AT FACE PLATE.
STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING
APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS.
CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES
11. PROVIDE COLORED FACEPLATES FOR ELECTRICAL OUTLETS & SWITCHPLATES TO MATCH
SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED
32.
WHERE STRUCTURAL BEAMS, DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED
EXISTING, UNLESS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TO
BY CONSTRUCTION CREWS.
PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE
PURCHASE.
DAMPERED IF REQUIRED.
13.
THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF
12. PROVIDE JUNCTION BOXES OR POWER POLES AT WORKSTATIONS WHERE SHOWN.
DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST
33.
CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN
REFER TO THE PLAN FOR THE APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE
PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS ,a 24"O.C., INSULATION AND 6
INDICATOR OF BUILDING TYPE. BUILDING TYPE LISTED ON 1_100 IS BASED UPON AVAILABLE
TENANT'S DATA VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM
MIL VAPOR BARRIER ON EACH SIDE.
INFORMATION AND FIELD VERIFICATION.
WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE
FOR WIRING THE BASE PANELS OF THE WORKSTATIONS.
14.
CONTACT THE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED
34.
CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND
BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF
WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW
13. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE
THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING
CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED.
SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL
MECHANICAL DUCTWORK MAY PREVENT THE INSTALLATION OF LIGHTING FIXTURES AS
CONDUITS TO JUNCTION BOXES.
INDICATED ON THE CEILING PLAN).
MILL/CASEWORK
NOTES
14. IF REQUIRED, AND AS NECESSARY, PROVIDE NEW BALLASTS AND LAMPS IN ALL LIGHTS IN
15.
SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY,
EXISTING SPACES. CONSULT WITH LANDLORD.
PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT
OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE.
1.
CASEWORK AND MILLWORK GENERALLY INDICATED ON THESE DRAWINGS ARE TO BE
15. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE
PROVIDED UNDER THE GENERAL CONTRACT.
NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES.
16.
PROVIDE FIRE -TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS
INCLUDING MILLWORK, WALL STOPS, CABINETRY, ETC.
2.
UNLESS INDICATED OTHERWISE, COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE
16. ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEET A.D.A.
(A.W.I.) CURRENT STANDARDS FOR CUSTOM GRADE WOODWORK.
REQUIREMENTS.
17.
SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR
APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO
3.
FURNISH SHOP DRAWINGS ON ALL MILLWORK AND CASEWORK FOR APPROVAL BY THE
17. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE (1) GANG BOX WITH A SINGLE
DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT
TENANT AND SCHOTT DESIGN PRIOR TO FABRICATION.
COVER PLATE.
INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER.
4.
WHERE CASEWORK AND MILLWORK ARE TO BE INSTALLED, VERIFY ALL DIMENSIONS ON
18. CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWN LIGHTS,
18.
EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT
PLANS AGAINST DIMENSIONS OF AS -BUILT CONDITIONS IN FIELD. REPORT ANY
SMOKE DETECTORS, SPRINKLER HEADS, AND EXIT SIGNS UNLESS OTHERWISE NOTED.
TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF
DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL CONTRACTOR. MAKE
MATERIALS AND EQUIPMENT.
ADJUSTMENTS TO CASEWORK AND MILLWORK TO FIT FIELD CONDITIONS UNLESS DOING
19. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC.
SO WILL SIGNIFICANTLY ALTER THE INTENT OF THE DESIGN SHOWN ON THE DRAWINGS.
EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURESFINISH
NOTES
5.
VERIFY FINISHES (LAMINATE, VENEER, STAINS, ETC.) ON THE SECTIONS AND ELEVATION
WITH FINISHES INDICATED ON THE FINISH PLAN/SCHEDULES. IMMEDIATELY
SHOWN ON PLAN ARE FOR REFERENCE ONLY.
DRAWINGS
REPORT ANY DISCREPANCIES TO SCHOTT DESIGN THROUGH THE GENERAL
20. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY
1.
ALL FINISHES SHALL COMPLY WITH CHAPTER 8 (INTERIOR FINISHES) OF THE INDIANA
CONTRACTOR.
SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM &
DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE FOR CLASS A FIRE RATINGS.
6.
REFER TO MILLWORK SECTIONS & ELEVATIONS. UNLESS OTHERWISE SHOWN, PLASTIC
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
2.
FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM
LAMINATE CLAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED.
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS
ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS,
BACKSPLASHES TO BE FIELD APPLIED.
OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION.
CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR
7.
EDGES PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWERS TO BE PLASTIC
FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR
NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS
LAMINATTEE AND NOT PVC OR OTHER STOCK PLASTIC EDGING UNLESS NOTED
EXPENSE.
3.
ALL NEW PLATES AND SWITCHES ARE TO MATCH EXISTING COLOR, UNLESS OTHERWISE
OTHERWISE.
21. COORDINATE WITH THE OWNER/TENANT PRIOR TO INSTALLATION OF FIRE DETECTION
NOTED. REMOVE ALL PLATES BEFORE PAINTING AND REATTACH AFTERWARDS.
8.
REFER TO MILLWORK SECTIONS &ELEVATIONS FOR CABINETRY SPECIFICATIONS
DEVICES REGARDING ALL DEVICE LOCATIONS TO AVOID CONFLICT WITH FEATURE
CONTRACTOR TO CONFIRM EXISTING COLOR PRIOR TO PURCHASING NEW.
(CUSTOM PLASTIC LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY).
WALLS (CONFERENCE ROOMS AND RECEPTION AREAS) AND TENANT -INSTALLED ITEMS
(I.E. PRESENTATION BOARDS, AN EQUIPMENT AND PROJECTION SCREENS).
4.
ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AND TWO (2) FINISH
9.
TO PROVIDE BLOCKING IN WALLS FOR ALL MILLWORK, WALL STOPS, HARDWARE, AND
COATS.
CABINETRY WHERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED.
5.
FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR
OPENINGS AS NOTED ON FINISH PLAN (I.E. WHERE VCT MEETS CARPET).
6.
WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE
NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK.
PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING
DOCUMENT APPROVAL
OWNER.
7.
REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED,
TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE
8.
WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO
MATCH ADJACENT WALL FINISH.
9.
SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT
TENANT/CLIENT COMANY NAME TENANT REPRESENTATIVE SIGNATURE
DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL
MILLWORK.
ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCU
10.
REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH
THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE
INFORMATION.
USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOT
11.
ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE LOW VOC CONTENT.
12.
ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT
MANUFACTURER.
DEMOLITION NOTES
1. COORDINATE DEMOLITION WITH NEW WORK CONSTRUCTION DRAWINGS IN ORDER TO
DETERMINE THE FULL EXTENT OF NECESSARY DEMOLITION. SALVAGE REUSABLE ITEMS.
2. NO STRUCTURAL OR LOAD-BEARING CONSTRUCTION SHALL BE REMOVED,
DEMOLISHED, OR DAMAGED AS A RESULT OF THIS PROJECT UNLESS SPECIFICALLY
NOTED OTHERWISE ON THE DRAWINGS. PROTECT ALL EXISTING STRUCTURAL MEMBERS
DURING DEMOLITION/CONSTRUCTION. THE CONTRACTOR SHALL VERIFY IN THE FIELD,
PRIOR TO DEMOLITION, THAT ALL ITEMS NOTED TO BE DEMOLISHED ARE NOT
STRUCTURAL. CONTACT SCHOTT DESIGN IMMEDIATELY IF THE CONTRACTOR(S) IN THE
FIELD SUSPECT THAT AN ITEM NOTED FOR DEMOLITION APPEARS TO BE STRUCTURAL OR
OTHERWISE LOAD-BEARING. BEWARE OF STRUCTURAL COLUMNS AND/OR BEAMS THAT
MAY BE CONCEALED BEHIND FINISHES THAT ARE NOTED FOR REMOVAL. EXERCISE
CAUTION WHEN DEMOLISHING BUILDING FINISHES OR PARTITIONS ADJACENT TO OR
AROUND STRUCTURAL MEMBERS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR
INADVERTENT DAMAGE TO THE BUILDING STRUCTURAL SYSTEM.
3. PRIOR TO DEMOLITION, COORDINATE WITH THE OWNER IN THE FIELD REGARDING
THOSE ITEMS THAT MAY BE REMOVED AND REUSED. CONFIRM WITH THE OWNER THOSE
ITEMS THE OWNER CHOOSES TO RETAIN FROM DEMOLITION, AND THOSE ITEMS OF
WHICH THE OWNER CHOOSES TO DISPOSE. COMPLY WITH THE OWNER'S REQUESTS.
4. WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE
BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN
THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING
AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY
OWNER.
5. REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR
DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DEMOLITION PLAN.
VISIT AREA OF WORK TO ASSURE EXTENT OF DEMOLITION.
6. REMOVE ALL CARPET, VINYL BASE, VCT, WALL FABRIC, AND ANY OTHER FINISHES AS
REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING
CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING
FINISHES TO REMAIN.
7. REMOVE ALL ELECTRICAL OUTLETS AND CONDUCTORS AS REQUIRED OR INDICATED.
SALVAGE OUTLETS FOR REUSE IN NEW CONSTRUCTION.
8. REFER TO DEMOLITION PLAN AND REFLECTED CEILING PLAN LEGEND FOR CEILING GRID
INSTRUCTIONS.
9. USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO
REMAIN SUCH AS, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION
EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE
CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY
SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE
BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE
OWNER'S USE IN THE PROJECT.
10. PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION)
REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING
BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES,
AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES/RACEWAYS, AND PLTC CABLES.
REFER TO SECTION 300.21.
11. WHERE FIXTURES OR EQUIPMENT ARE REMOVED FROM ANY ELECTRICAL, PLUMBING,
MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE
CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND
GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL
TERMINATED SYSTEMS FOR FUTURE REFERENCE. CONTRACTOR TO PROVIDE AN
"AS -BUILT" SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS.
12. GENERAL CONTRACTOR TO PROVIDE RECYCLING COSTS TO THE BUILDING
OWNER/LANDLORD ON ALL ITEMS BEING DEMOLISHED, SUCH AS, METAL STUDS,
DRYWALL, CARPET, CEILING TILES, DOORS,GLASS, AND CABINETRY.
FIRE PROTECTION NOTES
1. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE
EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH
OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL
DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
2. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE
GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN,
INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE
SPRINKLER SYSTEM.
3. THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE,
THE INDIANA FIRE CODE, AND ALL OTHER APPLICABLE LAWS, CODES, RULES AND
REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE
SUPPRESSION SYSTEMS.
4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND
SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
5. PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED. PROVIDE
MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE.
FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK.
i'1'trt=c VNSIi
-
EPi\h It 01 � 0\1\1.1\I1Y St ID\ k F� - hLlll_i)IN( &��`l)E �EI�\'iCI:
# 1 c-
I\ k. - C \R,\MEL IN A60 3-'
"IM 57!-'444 - I A\ "3i71 571-'499 - I\ I EI:\E1
PLAN AZ, 11JENTICATION CERTIFICATION & AGREEMENT
As an authorize agent responsible for permitting, including but not limited to obtaining
permit/s*, I certify that these plans are identical to the plans released for construction
by the State of 'Indiana Department of Homeland Security, Division of Fire & Building
Safety. I also understand that if it is determined that these plans are not identical, a
Stop Work Order will be served, as required under the ordinances referenced below.
Authorized Si nature Printed Name Date
' Permitting is required under Carmel City Code under Chapter 7, entitled "Building Code", Section 9 and under Chapter 10, entitled
"Zoning and Subdivisions", Section i and under Carmel Zoning Ordinance under Chapter 29, entitled "Administration", Sections 4.2 and
4.4 and under Chapter 31, e-ttitled "General Pro0sion<-". Section 31.1.
S.!Rvnit� F.rtm�i .4ppiicati.miPlun Auai,cnncehon
N
VICINITY MAP KEY PLAN - 2ND FLOOR
NOT TO SCALE NOT TO SCALE
INDEX OF DRAWINGS
T111 COVER SHEET AND GENERAL PROJECT NOTES
SCOPE OF WORK CONTAINED IN THESE DOCUMENTS.
1_100 LIFE SAFETY PLAN
D111 DEMOLITION PLAN
TENANT REPRESENTATIVE PRINTED NAME DATE Al I I ARCHITECTURAL FLOOR PLAN
MENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT. A121 REFLECTED CEILING PLAN: HVAC / LIGHTING
EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE Al 31 FINISH PLAN
T DESIGN.
E111 ELECTRICAL PLAN
o
_ O
O 0 O U
O0
N Z
vi 0
Cr 0 t� O
LJ O U
O C �?
LO 0 Q 3
C
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOTT DESIGN.
O
CN
N
W
N �
Z
y `
oc Q 1 v)
i- V CD J
Z
W- - CL
y Q
QWpz
IR Q
U:*
Up
QpZ
= O•
LL O V3
I
O F" -
Q
W Q °�,
CL w
W O
r-
L�L L0
ISSUE
DATE DESCRIPTION
07.12.17 REVIEW SET
07.27.17 PERMIT SET
REVISONS
MARK DATE DB IDESCRIPTION
w�f AR10700017�
STATE��OFff
nnln�
PROJECT NUMBER
2017.273
PROJ. MGR DRAWN BY
SLF/AS SLF
2ND FLOOR
COVER SHEET AND
GENERAL NOTES
T1 1 1