HomeMy WebLinkAbout17080173.22 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CODE SUMMARY SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE PREVIOUS USE OF SPACE BUSINESS) OCCUPANCY CLASSIFICATION B(USINESS) CHANGE OF OCCUPANCY CLASS? NO TOTAL BUILDING AREA 26,752 SF/FLOOR X 5 STORIES = 133,760 SF TOTAL PROJECT AREA OCCUPANCY CALCULATIONS NUMBER OF EXITS 1,563 SF SPACE TYPE AREA SF PER OCCUPANT OCCUP LOAD GEN. OFFICE 1,563 SF 100 16 TOTAL OCCUPANTS IN PROJECT AREA 16 REQUIRED: 1 PROVIDED: 2 SPRINKLER SYSTEM (YES/NO) YES - EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 26,752 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASHRAE 90.1 SUMMARY EXEMPT (SEE REFLECTED CEILING PLAN) BUILT BEFORE 1978? NO BUILDING CONSTRUCTION TYPE II -B LEGEND EP I EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT- BUILDING STAIR LOCATION TRA QI Fc FIRE EXTINGUISHER EXIT SIGN i EMERGENCY LIGHT TRAVEL DISTANCE LIFE SAFETY NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. GENERAL NOTES Ll I. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. o F _O O o O U N-qOa 0 l V) Z V 00 0 p w O U O C -1 L c THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. O 0 � Nuj N �z y oc Q JENNE V C� z0 LU n Q QWO z oc Q U:* Up Qoz = O• limmo■ LL. O sommol O�� 42' Q W Q °' CL LU W Q LL Lo ISSUE DATE DESCRIPTION 07.12.17 REVIEW SET 07.27.17 PERMIT SET REVISONS MARKT DATE DB iIDESCRIPTION H Soy'w N 0. 1 AR10700017 iF STATE ,,OFA� PROJECT NUMBER 2017.273 PROJ. MGR DRAWN BY SLF/AS SLF 2ND FLOOR LIFE SAFETY AREA NOT IN CONTRACT AREA OF WORK LIFE SAFETY PLAN 0 4' 8' 16'