Loading...
HomeMy WebLinkAbout17080173.4ARCHITECTURAL LEGEND NEW CONSTRUCTION 71 WALL v7z= PARTIAL HEIGHT WALL m ---a WINDOW / SIDELIGHT ## DOOR AND FRAME (SEE DOOR SCHEDULE) EXISTING TO REMAIN WALL ® PARTIAL HEIGHT WALL �-� WINDOW / SIDELIGHT 7 DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE W71 UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. W1 STANDARD WALL 2-1/2 " METAL STUDS AT 16" O.C.; ONE LAYER OF %" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING WALL WITH INSULATION 2-1/2 " METAL STUDS AT 16" O.C.; ONE LAYER OF %" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING DEMISING WALL TO DECK W3 WITH INSULATION 2-1/2" METAL STUDS AT 16" O.C.; ONE LAYER OF %" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL W4 DEMISING WALL WITH SECURITY MESH 3%" METAL STUDS AT 16" O.C.; ONE LAYER OF %" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" SOUND BATT INSULATION EACH SIDE OF WALL ABOVE CEILING; PROVIDE METAL SECURITY MESH ON TOP OF WALL ABOVE CEILING TO DECK GENERAL NOTES 1. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. ALL EXISTING FINISHES TO REMAIN UNLESS NOTED OTHERWISE; WHEN APPLICABLE, NEW WALLS ARE TO BE BUILT ON TOP OF EXISTING FINISHES. CONTRACTOR TO VERIFY EXISTING STUD SIZE IN FIELD; NEW WALLS ARE TO MATCH EXISTING STUD SIZE PLAN NOTES ALL NOTES ARE NOT USED.a PATCH AND REPAIR WALL WHERE EXISTING RECESSED MONITOR WAS REMOVED AND PREP TO RECEIVE NEW FINISH. PROVIDE OA01 NO ARCHITECTURAL WORK IN THIS ROOM OR AREA; EXISTING TO BLOCKING IN WALL FOR NEW WALL MOUNTED TELEVISION IN THIS REMAIN. LOCATION. CONFIRM EXACT REQUIREMENTS AND LOCATION WITH TENANT. ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS A02 STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. CONTRACTOR TO PROVIDE NEW FIRE EXTINGUISHER IN THIS A03 LOCATION. FIRE EXTINGUISHER IS TO MATCH STYLE OF EXISTING IN THIS SUITE. IF IN PORPWER WORKING ORDER, REUSE EXISTING FIRE EXTINGUISHERS SALVAGED FROM DEMOLTION. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. A04 EXISTING FIRE EXTINGUISHER AND CABINET TO REMAIN. CONTRACTOR TO CONFIRM THAT ALL FIRE EXTINGUISHERS ARE TO INSTALLED ACCORDING TO NFPA 10. A05 CONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W3". IF NOT ALTER EXISTING WALL AS REQUIRED TO MATCH "W3". A06 PROVIDE ADDITIONAL BLOCKING IN WALL AS REQUIRED FOR WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. TELEVISION TO BE PROVIDED BY CONTRACTOR; CONFIRM WITH TENANT ON EXACT REQUIREMENTS AND IF EXISTING TELEVISIONS CAN BE REUSED OR IF NEW NEED TO BE PURCHASED. A07 ALL APPLIANCES IN BREAK ROOM ARE TO BE NEW AND PROVIDED BY CONTRACTOR. PROVIDE CUT SHEETS TO TENANT FOR APPROVAL PRIOR TO ORDERING. SEE ELEVATIONS 2/A211 AND 3/A21 1 FOR MORE INFORMATION. A08 COORDINATE WITH TENANT ON LOCATION AND REQUIREMENTS FOR NEW WALL MOUNTED SIGNAGE. PROVIDE BLOCKING AND PATCH AND REPAIR WALL AFTER INSTALLATION AS REQUIRED. A10 REINSTALL SALVAGED BASE CABINETS AS SHOWN. PROVIDE NEW SOLID SURFACE (SSI) COUNTERTOP IN SAME LAYOUT AND DIMENSIONS AS COUNTERTOP THAT WAS REMOVED. COUNTER TO HAVE NO BACKSPLASH; SCRIBE COUNTER TO WALL AND PROVIDE BEAD OF CLEAR SILICONE AT SOLID SURFACE TO WALL TRANSITION. Al 1 PROVIDE SEPARATE PRICE FOR NEW SOLID SURFACE (SS1) COUNTER AT 42 A.F.F. NEW COUNTER TO BE 24"W x 8'-0" L (APPROX). COUNTER TO HAVE NO BACK SPLASH; SCRIBE COUNTER TO WALL AND PROVIDE BEAD OF CLEAR SILICONE AT COUNTER TO WALL TRANSITION. CASEWORK CONTRACTOR TO INSTALL RAKKS EH -1818 -FM BRACKET AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. P01 PROVIDE NEW SINK AS SHOWN. DESIGN INTENT IS FOR NEW SINK TO BE IN SAME LOCATION AS EXISTING AND PLUMBING REUSE. IF NOT POSSIBLE, PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. 002 PROVIDE WATER LINE FOR COFFEE, WATERCOOLER AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. P03 PROVIDE ALL NECESSARY PLUMBING AND DRAINS FOR TENANT PROVIDED DISHWASHER AND ICE MAKER AT THIS LOCATION. AREA NOT IN CONTRACT ARCHITECTURAL PLA N 0 2' 4' 8' 16' ❑ AREA OF WORK O i N O N oO U a) v O0 v) Z in r\ O V 0 .p = C7 0` 0 r\ O UJ iD U O C v! Lo 70 Q C THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. O � N N W N I-- � = z oc Q U (D I z0 Lu �WNQ Ln GL QWO z w U:* Up Qoz = O. LL O c~ I Qp 3: W Q °1-1 CL LJJ W (D LL Lo ISSUE ! DATE DESCRIPTION 07.12.17 REVIEW SET 07.27.17 PERMIT SET REVISONS MARK DATE I DB IDESCRIPTION H Boy N o. s� O AR10700017 T STATE �OF� U = " PROJECT NUMBER NUMBER 2017.273 PROJ. MGR DRAWN BY SLF/AS SLF i 2ND FLOOR ARCHITECTURAL FLOOR PLAN �N% A111