HomeMy WebLinkAbout17080173.5LEGEND NEW OR RELOCATED EXISTING TO REMAIN a `1 LIGHT FIXTURE, 2'x4', LIGHT FIXTURE, 2'x4', FLUORESCENT, PARABOLIC FLUORESCENT, PARABOLIC (m3 LIGHT FIXTURE, 2'x2', ® FLUORESCENT. PARABOLIC RECESSED LIGHT FIXTURE RECESSED DIRECTIONAL LIGHT FIXTURE NL NIGHT LIGHT aLIGHT FIXTURE, 2'x2', FLUORESCENT. PARABOLIC RECESSED LIGHT FIXTURE RECESSED DIRECTIONAL LIGHT FIXTURE i' EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE EMERGENCY LIGHT EMERGENCY LIGHT FIXTURE FIXTURE $N LIGHT SWITCH LIGHT SWITCH $N3 LIGHT SWITCH, 3 -WAY $3 LIGHT SWITCH, 3 -WAY $ND LIGHT SWITCH, DIMMER $D LIGHT SWITCH, DIMMER $NP SWITCH, PROJECTOR SCREEN $NG SWITCH. GARBAGE DISPOSAL (ABOVE COUNTERTOP) i — LIGHT CIRCUIT sP $G SWITCH, PROJECTOR SCREEN SWITCH, GARBAGE DISPOSAL -' LIGHT CIRCUIT CEILING GRID, CEILING GRID, SUSPENDED, 2'x4' SUSPENDED, 2'x4' CEILING GRID, CEILING GRID, SUSPENDED, 2'x2' SUSPENDED, 2'x2' CEILING GRID, SUSPENDED, 4'x4' TEES TO COMPLETE CEILING GRID, GRID SUSPENDED, 4'x4' GYPSUM BOARD GYPSUM BOARD CEILING CEILING EXPOSED TO DECK RELOCATED DIFFUSER, LAY -IN. 2'x2' RELOCATED DIFFUSER, LAY -IN, 1'x4' RELOCATED DIFFUSER, LAY -IN, 4"x4' In EXHAUST FAN, 2'x2' ® EXISTING DIFFUSER, LAY -IN, 2'x2' ® EXISTING DIFFUSER, LAY -IN, 1'x4' EXISTING DIFFUSER, LAY -IN, ® 4"x4' EXISTING EXHAUST FAN, 2'x2' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELOCATE DIFFUSERS & GENERAL NOTES 1. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 8'-8" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. UNLESS NOTED OTHERWISE, THE LIGHTS SHOWN AS "NEW OR RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENT IS LESS THAN 50% OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90. 1, CONTRACTOR MUST NOTIFY SDI. 5. IF PROJECT CRITERIA REQUIRES ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, OR RELAY TIME CLOCK CONTROLS (COORDINATE WITH SDI). EXISTING SWITCHES TO BE CONVERTED IF REQUIRED BY CODE. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. MECHANICAL NOTES 1. MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. PLAN NOTES ALL NOTES ARE NOT USED. OR01 NO CEILING WORK IN THIS AREA. ALL EXISTING FIXTURES AND SWITCHES TO REMAIN. R02 ALL NEW AND EXISTING LIGHTING IN OPEN OFFICE AND CORRIDOR ARE TO BE CONTROLLED BY EXISTING 3 -WAY LIGHT SWITCHES. R03 EXISTING DRYWALL BULKHEAD TO REMAIN. PATCH AND REPAIR AS REQUIRED PER REMOVAL OF PENDANT LIGHT. REPAINT ENTIRE BULKHEAD TO MATCH EXISTING COLOR AS REQUIRED. R04 PROVIDE NEW RECESSED DOWN LIGHT TO MATCH EXISTING IN BULKHEAD. DESIGN INTENT IS FOR NEW RECESSED DOWN LIGHT TO ALIGN WITH EXISTING RECESSED CAN LIGHTS IN BULKHEAD. R05 EXISTING LIGHT FIXTURES TO REMAIN. PROVIDE NEW LAMPS IN ALL EXISTING FIXTURES IN THIS ROOM. CONFIRM EXACT REQUIREMENTS WITH TENANT. RO6 PATCH AND REPAIR CEILING GRID AND TILE AS REQUIRED PER REMOVAL OF WALL. DESIGN INTENT IS FOR CEILING GRID TO AND TILE TO APPEAR CONTINUOUS IN THIS AREA. IF CEILING GRIDS DO NOT ALIGN, CONTACT SDI TO COORDINATE CEILING OPTIONS IN THIS AREA. MECHANICAL DIFFUSER RELOCATION A. 2 `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION AREA NOT IN CONTRACT ❑ AREA OF WORK REFLECTED CEILING PLAN 0 2' 4' 8' 16' O F _ O O � O U -%j- (D c V) Z - � O _9__ V 0 o Q O wU O c� O C 'n LO .0 Q 3 c 3 � 3 THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. Q N W Z N o0 Q z W. CL i■r� W cn Q WOz Q w Q Up V 7 Q Q Z = O� F.. LL O V) Q oc `O WQ °� LLj W (:D I Ln ISSUE DATE DESCRIPTION 07.12.17 REVIEW SET 07.27.17 PERMIT SET REVISONS MARK DATE ; DB IDESCRIPTION No. _ AR10700017 STATE OF �C� A • FRV P�►� nm PROJECT NUMBER 2017.273 PROJ. MGR DRAWN BY SLF/AS SO I f 2ND FLOOR REFLECTED CEILING PLAN N