Loading...
HomeMy WebLinkAbout17080173.7LEGEND GENERAL NOTES PLAN NOTES NEW CONSTRUCTION EXISTING TO REMAIN 1. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF ALL NOTES ARE NOT USED. FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX E01 NO ELECTRICAL WORK IN THIS ROOM. ALL EXISTING TO REMAIN. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF POWER OUTLET, QUADRUPLEX POWER OUTLET, QUADRUPLEX THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. E02 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. JUNCTION BOX 0 JUNCTION BOX 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET :a CEILING MOUNTED CEILING MOUNTED ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR E03 O INTO CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT JUNCTION BOX JUNCTION BOX MAG -LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE 60" & 42" A.F.F. SEE ELEVATION 2/A211 FOR MICROWAVE u BOX, BLANK COVER PLATE © BOX, BLANK COVER PLATE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. LOCATIONS. BOX, OPEN © BOX, OPEN 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS PROVIDE POWER AND DATA AT 60" A.F.F. FOR CONTRACTOR � BOX, OPEN OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED E04 PROVIDED, WALL MOUNTED TELEVISION. COORDINATE EXACT CABLE TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES LOCATION WITH TENANT, CONFIRM WITH TENANT IF SALVAGED p POWER POLE FOR P POWER AND DATA POLE AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE TELEVISIONS CAN BE REUSED OR IF NEW NEED TO BE PURCHASED. m ELECTRICAL AND DATA. EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL PROVIDE JUNCTION BOX CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL PROVIDE JUNCTION BOX AT THIS LOCATION FOR TENANT'S ABOVE CEILING. WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND E05 DISHWASHER AND GARBAGE DISPOSAL. FLOOR BOX WITH POWER FLOOR BOX WITH POWER MUST COMPLY WITH ALL APPLICABLE CODES. PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE F6 <7 AND DATA, FLUSH �IQ AND DATA, FLUSH E06 O SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S MOUNTED MOUNTED FURNITURE VENDOR. FLOOR BOX WITH FLOOR BOX WITH JUNCTION BOX AND J <7JUNCTION BOX AND EXISTING OUTLETS ARE ON EXISTING WALL BELOW WHERE DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED E07 TRANSOM WINDOW IS BEING REMOVED. EXISTING OUTLETS TO REMAIN IF POSSIBLE. DATA/COMMUNICATION DATA/COMMUNICATION b OUTLET (PROVIDE BOX b OUTLET EXISTING PROJECTOR TO REMAIN IN THIS ROOM. PROVIDE NEW AND PULL STRING ONLY) E08 TELEVISION AS NOTED. DED DEDICATED CIRCUIT PROVIDE POWER AND DATA AT 60" A.F.F. FOR TENANT'S WALL GFCI GROUND FAULT CIRCUIT E09 MOUNTED TELEVISION. IF POSSIBLE, REUSE ELECTRICAL FROM INTERRUPT OUTLET RECESSED MONITOR THAT WAS REMOVED. CONFIRM EXACT LOCATION AND REQUIREMENTS WITH TENANT. +42" HEIGHT OF ELECTRICAL OR DATA DEVICE CONFIRM EXISTING HEIGHT OF RELOCATED CASEWORK PRIOR TO E10 INSTALLING ELECTRICAL. IF RELOCATED CASEWORK IS 3'-0" HIGH, ALL ELECTRICAL IS TO BE AT 44" A.F.F. AS SHOWN. IF RELOCATED CASEWORK IS 2'-10" HIGH, ALL ELECTRICAL SHOWN IS TO BE AT 42" A.F.F. AREA NOT IN CONTRACT ELECTRICAL PLA N 0 2' 4' 8' 16' F1AREA OF WORK O F7 _ O N'o O U O O V)Z�'� V co o` 0 O LU O U O C N C THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. IIIIIIIIIIIIIIIIIIIi ISL O V) � o F - W Q °� _ CL L1J W L1. L0 ISSUE DATE DESCRIPTION 07.12.17 REVIEW SET 07.27.17 PERMIT SET REVISONS MARK! DATE I DB IDES CRIPTION ��.���N H No. s� AR10700017 STATE OF cz�T PROJECT NUMBER 2017.273 PROD. MGR DRAWN BY SLF/AS SLF E 2ND FLOOR ELECTRICAL PLAN N E 1 1 1