HomeMy WebLinkAbout026-92 SP Windpointe at Waterstone Sec 1 Sanitary SewerFOR CONTINUATION
� SEE THIS SHEET
I�1
16 �
LAT. 10' OUT
OF MANHOLE
1
785
775
770
765
r•�
755
750
745
Tc -781.50 Existing Grade
Tc -779.20 __------------------ -------------�
New Grade
Inv - 773.00 (E)
N
U
N
0
i
236' OF 8' P.V.C. 0 0.45%
Inv - 771.94 (W) -
0
i
U
Inv - 771.84 (E)
o
387' OF 8' P.V.C. 0 3.32%
Homer MoLEr sirs.
"DON'T
DIG
BLIND"
1-800-382-5544
CALL TOLL FREE
1-800-428-5200
FOR CALLS OUTSIDE OF INDIANA
FOR CON TI N U ATI ON
2
� 6
WYE \ 0 8 T.
+
25
\ WYE & LAT. \ \
\ 2+63/
24
WYE k LAT. -
1+36
27
LAT. 10' OUT
OF MANHOLE
- � SEE SHEET S-11 � � /
18 � \ '� �� ��a'C / \ � Son. MH Na 9 4
1 18
` 7 San. MH No. 11
r _ - FOR CONTINUATION
1 / WYE k LAT. WYE & LA' SEE SHEET S-11
1 0+73 7 +,+65 San. MH No. 8 4
17 8 12 s-16
6 WS-16YE & LAT. \ \/ / \ / / \ \ S-16 5. LATERALS RUNNING TO THE OPPOSITE SIDE OF
1+97 \ STREET SHALL EXTEND S' PAST THE RIGHT OF
FOR CONTINUATION ` Sm MH No, 7 7 WAY UNE (PROPERTY UNE)
SEE THIS SHEET \ / ' ` (DROP MANHOLE) 5-16 6. IT SHALL BE THE CONTRACTORS RESPONSIBILITY
5 NOTES• TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE
San. MH No. 14
Tc -765.00
Inv - 758.99 (W)
/
\
CONSTRUCTION BEGINS.
v
U
�
O
1. ALL CUTS ARE TAKEN FROM THE EXISTING GRADE
M
j
Z
N
\
TO THE PIPE INVERT.
7. TEMPORARY TRAFFIC CONTROL DURING
^
J
O
S
r-
CONSTRUCTION TO CONFORM TO APPLICABLE
7
\
\
\
2. STATIONS
LOCAL AND STATE STANDARDS.
C7 r -
\
FROM NEAREST DOWNSTREAM ( )
8. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE
.......�.��3�'''���.
��..
i \
\
c �
3. WYES AND LATERALS TO BE 6" PIPE UNLESS
PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A
� �; LL
O
OTHERWISE SPECIFIED.
STANDARDS FOR WORKER SAFETY.
.Q
o CD �; z
(n
z
1 O
9. CONTRACTOR SHALL MINIMIZE DAMAGE TO
z
4. ALL WYE CONNECTIONS SHALL HAVE A MINIMUM
EXISTING TREES.
16
FOR
CONTINUATION
FIVE FOOT LATERAL EXTENSION CONNECTED TO
FOR STATIONS AND OFFSETS
•..........
THE WYE. THE END OF THE LATERAL SHALL BE
10. OF STRUCTURES SEE*a
�.
WYE a LA 7
SEE
THIS SHEET
PLUGGED OR CAPPED.
SHEET S-3.
'''r,�u �,�►►``'
1+5a
SANITARY SEWER PLAN SCALE: ,"=so'
�Existing Grade
New Grade Tc -778.00
,�-------__ __ Tc -776.80
Tc- ,5 0 --- -- - ---
--
Granular
i
o Backfill
/ N
Inv - 770.00 (N)
-
QTc -764.50 _------ Tc -765.00 Inv 768.82 (S)
Inv - 767.00 (N)
- ----- ---- 8"PVC
Inv - 765.69 (S) Inv - 767.20 (W)
Granular
Backfill
U8" STUB Iry - 752.50 (5)
8'PSC --- If,y - 751.'4 (N}
Inv - 751.74 (N) �
Inv - 752.90 N
N
8"PVC 253' OF 8' P.V.C. 0 0.42%
Inv - 751.64 S - --- -- - - --- - -
I
.IS
8"P VC
Inv - 758.99 (W)
8"P Vc ci IS c
Inv - 751.64 (S)/ 750.91 (E)
J
Inv 751.11 (N)
125' OF 8' P.V.C. ® 0.42% 292' OF 8' P.V.C. ® 0.45% 118' OF 8' P.V.C. ® 1.00%
CIO
Q7
v
U
�
O
M
Z
N
z
^
J
O
S
r-
7
c
N
f
c
O
C7 r -
LO
n -
E-/ORZ.:
c>
c �
O
O
O
V)
(n
z
1 O
z
z
Q z
2
CD
CD
c
o
o
pc
?
o
c
c
N
CN
8"P VC
Inv - 758.99 (W)
8"P Vc ci IS c
Inv - 751.64 (S)/ 750.91 (E)
J
Inv 751.11 (N)
125' OF 8' P.V.C. ® 0.42% 292' OF 8' P.V.C. ® 0.45% 118' OF 8' P.V.C. ® 1.00%
785
z
0
V)
W
cr
0
780
Q
o
a
o
U
�10�!
LJ
LJ
z
0
z
LJ
oc
770 W
4
w
z
U
V)
7 6 5 Ej�
760
0
z-
755 755
o�-
Doc
750
CIO
Q7
v
U
�
O
Z
Z
z
O
s
c,
O
S
O
7
c
N
f
c
O
LO
n -
E-/ORZ.:
c>
c �
r
V)
(n
785
z
0
V)
W
cr
0
780
Q
o
a
o
U
�10�!
LJ
LJ
z
0
z
LJ
oc
770 W
4
w
z
U
V)
7 6 5 Ej�
760
0
z-
755 755
o�-
Doc
750
CIO
Q7
O
O
Z
Z
z
s
c
N
c
O
LO
1 ;;=50'__
E-/ORZ.:
SCALE:
785
z
0
V)
W
cr
0
780
Q
o
a
o
U
�10�!
LJ
LJ
z
0
z
LJ
oc
770 W
4
w
z
U
V)
7 6 5 Ej�
760
0
z-
755 755
o�-
Doc
750