HomeMy WebLinkAbout17090017.51 , 63„ 4 CV 31" 2 COLUMN DETAILS HAFELE WF System • Maximum door height: 711 mm (28") • Maximum door thickness: 32 mm (1 1/4") • Minimum pocket width: Door thickness: 16 - 22 mm (5/8" - 7/8") = 45 mm (1 3/4") Door thickness: 22 - 32 mm (7/8" - 1 1/4") = 57 mm (2 1/4") • Recommended for entertainment systems, office furniture systems and institutional furniture, where the wood follower strip is finished to match the inside of the cabinet Note Wood follower strip to be customer suppliec. Backset- Door thickness +6 (114") Wood follower (fabricated by customer) Maximum thickness = 1/2" www.hafele.com rCJ.e- „ 2 11 _/ Scale: 1" = 1'-0" Sliding and Roller Shutter Systems Pocket Door Slide System Ball Bearing Slide Material: Steel; Color: black Length Max. Retraction --- Item No. 304 (12') _ 224(83/4') 408.10.3_02 454(18-) 374 (14 3/4") 408.10.455 504(20') 424 (16 3/4") 408.10.508 554(22') _ _ _ 474 (18 3/4") 408.10.553 604 (24") 524 (20 3/4') - - 408.10.606 Note Components listed on page 7.155 are needed for each door Min. Pocket — width I12 Max. (1!2" 06 cp Gl� t0 Cep a f 35 1318'° 2 Door thickness (1/16") J L- 2 9.5 (1/16") (5/16") Dimensions in mm Inches are approximate f C-7 BLOCKING AS REQ. HAFELE RETRACTABLE DOOR HARDWARE. ASTRAGAL ON DOORS. SINK PIPES BELOW ARE TO BE WRAPPED FOR COMPLIANCE WITH ADA GUIDELINES. 2 KITCHEn!ETTE SINK BASE Scale: 1/2" = 1'-0" OFFICE FLOOR PLAN Scale: 1/8" = 1'-0" GENERAL PROJECT NOTES - A. CONFORM TO ALL LOCAL COUNTY, STATE, AND CITY CODES HAVING JURISDICTION OVER THE PROJECT AND SITE, IF SUCH RULES AND REGULATIONS ARE IN CONFLICT WITH ANY PORTION OF THESE DOCUMENTS, THE ARCHITECT SHALL BE INFORMED BEFORE PROCEEDING. B. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY CONFLICTS PRIOR TO PROCEEDING WITH WORK. C. THE CONTRACTOR TO VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS OF FIXTURES AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS. D. THE DRAWINGS ARE NOT TO BE SCALED. FOR INFORMATION CONCERNING EXISTING PARTITIONS, ETC. VERIFICATION MUST BE DONE IN THE FIELD. E. THE USE OF THE WORDS "PROVIDE" OR "PROVIDED" IN CONNECTION WITH ANY ITEM SPECIFIED IS INTENDED TO MEAN, UNLESS OTHERWISE NOTED, THAT SUCH SHALL BE FURNISHED, INSTALLED AND CONNECTED WHERE SO REQUIRED. F. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND CERTIFICATES OF OCCUPANCY. G. ALL MEANS OF EGRESS AND FIRE PROTECTION SHALL BE MAINTAINED AT ALL TIMES. ANY SHUT DOWN OF LINE SAFETY OR BUILDING SYSTEMS SHALL BE APPROVED AND COORDINATED IN ADVANCE WITH THE OWNER AND LOCAL BUILDING DEPARTMENT. H. ALL CONTRACTORS ARE REQUIRED TO COORDINATE THEIR WORK WITH ALL DISCIPLINES TO AVOID CONFLICTS, SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION REGARDING SIZE AND QUANTITY OF OPENINGS, SLAB REQUIREMENTS AND LINTELS. I. ALL WALLS ARE 2X4 METAL STUDS AT 161° OC., UNLESS NOTED OTHERWISE, J. ALL DIMENSIONS ARE FROM FACE TO FACE OF STUDS. K. PROVIDE FIRE SEALANT AROUND ALL PENETRATIONS THROUGH RATED WALLS. L. PROVIDE CONTROL JOINTS IN GYPSUM BOARD ASSEMBLIES AS RECOMMENDED BY MANUFACTURER. PROVIDE CJ IN CEILINGS SO NO DIMENSION EXCEEDS 50' IN EITHER DIRECTION WHERE THERE IS PERIMETER RELIEF OR 30' IN EITHER DIRECTION WITHOUT PERIMETER RELIEF. DO NOT SEPARATE SUSPENSION SYSTEM. CAULK JOINT AND PAINT TO MATCH. M. 71 KEY PLAN NOTES 1. ALL WALLS AT- OFFICE PARTITIONS, CONFERENCE ROOM, PHONE BOOTH KITCHENETTE, AND AROUND LOBBY TO BE FULL HEIGHT TO DECK WITH SOUND BATT INSULATION. SEAL AROUND ALL PENETRATION AND AT WALL INTERSECTIONS WITH SOUND SEALANT. 2. TYPICAL CUBICLE WITH LOW WALLS. SEE DETAILS 6/A400. 3. MAINTAIN z" AIR SPACE BETWEEN EXISTING WALL AND NEW FRAMING. FILL CAVITY WITH SOUND BATT INSULATION. SEAL ALL PENETRATIONS WITH SOUND SEALANT. 4. LOW WALL, MATCH CUBICLE HEIGHTS AND TRIM DETAILS, 5/A400. 5. NEW DOWNSPOUT PIPE LOCATION. MINIMIZE INTRUSION INTO ROOM.. 6. SEE ELECTRICAL PLANS FOR PLYWOOD REQUIREMENTS FOR IT ROOM. 7, CASE OPEN AND INSTALL BLOCKING FOR FUTURE DOOR. 8. MOVE STAIR DOOR AND INFILL WALL. 9. DOUBLE FRAME THIS WALL. FRAME POCKET FOR TV. TRIM WITH PAINT GRADE WOOD, COLOR TO MATCH WOOD BASE. SEE ELEVATION ON A400. 10. 30" WORKSURFACE 11. 24" WORKSURFACE 12. BARN STYLE DOOR. COORDINATE DOOR HARDWARE WITH PDG. DOOR TO BE SIMILAR TO BUILDING 4 CONFERENCE ROOM, 13. NICHE - SEE DETAIL 6/A400. NOTE: ALL OP E KING S O R P E NETRATI ONS 1 I. E_ P WMg IMG VENTS, ETC. ) THROUG H THE FI RE RATED VALL, CE ILINGS ANEVOR FLOOR SYS TElii REQUIRE PROPER PROTECTrrE FIRE STOPPING. FIRECCL ARSAND FIRE CA L3'J4ING &HAILL HE P ROP E RI_Y I fiISTALLED, LOCATE D AT THE FIRST AND SE GN D FLOOR CEILING ATT IE HE IGH T OF TOP PLATES, S-ECOND AND THIRD FLOOR AT FINISHED FLOOR Lam, THIRD FLOOR CEILING AT MEG HT OF TOP PLATE S AND AN Y P EN ETRATI ONS O F RATE D WALL ASS E SLES. ,AIME 1 \_ f PEDCOR DESIGN GROUP LLC Architecture / Project Management: 355 City Center Drive Carmel. Indiana 46032 317.705.7979 (phone) 317.705.7980 (fax) Architect: �p9Nttilllhq;;,!/kU UTl�>,//� 00033126 = x STATE OF I MA ;Illi l may. Developer: P E D C O R DEVELOPMENT CO. Project: COPYRIGHT & OWNERSHIP OF DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE , PCPERTY CF THE ARCHITECT AND PFDCOR DESIGN GROUP, LLC All IYIFCRM.4TION CCNTAINFD HEREIN IS CCNFICFNTIA1.. RS SI. BMISSION +1.D Di TRIBUTICr: TO OTHER PARTIES IS ',GT TO BE CONSTRUED AS 'I BLICATIGD, IN DEROGATION OF CCIVIVC1, I P COPYRIGHT IIJTFILFCTUAL PROFERTY RI HT 0R CTHFR RESFR AFD RIGHTS ALL INF RM,ATION,' N AII,F-^. HFf FIN CONSTITUTF . THF OPIGIIAI AND �I PI ISHcC': P - HFF, 1- TF-- . t F - -' I - F r __ I F TIF I TII F I. i F F CFSL1I TI RL IL 1 P1, CIh _ IAL I EF .PI. 1, -.ATF,- COPIED. E'..,H;SITFD, PHCTOGRARHFD. Pl USHEC. Y MARFD OR OTHERWISE DISTRIBUTED IN .ANY WAY VITHCUT TI -F F IFIC ANC PRIOR WRITTEN C;ONSFNT OF THE AP. I. 1 T STUTZMAN PND PEDCOR DESIGN GROUP, LLC. O COPY RIGHT .'D15 5- -N A!A m Ina; CONSTRUCTION DOCUMENTS Set Issue Date Sheet Issue Date 8/11/2017 8/11/2017 Drawn By Checked By BBP BBP Last Revision Date-. TATE RELEASE SET 8/11/2017 Sheet Title: FLOOR PLAN 08/30/2017 ASI #1 BID SET SHEET: A1 00