GENERAL CEILING NOTES
1. CEILING HEIGHT DESIGNATED BY BENCHMARK ABOVE
FINISHED FLOOR (AFF).
2. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON
WALL AT DOORWAY TO ROOM. TYPICAL UNLESS NOTED
OTHERWISE, IN LOCATIONS OF 2 OR MORE SWITCHES IN
CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED,
TOA GANG PLATE CONDITION.
3. PROVIDE FIRE RATED DAMPERS REQUIRED AT FIRE
RATED WALLS.
4, TRADES TO COORDINATE THE HEIGHT OF FIRE
SUPPRESSION LINES, ROOF DRAIN LEADERS. ROOF
STACKVENTS AND CONDENSATE LINES TOALLOW FOR
CEILING HEIGHTS AS INDICATED ON THE REFLECTED
CEILING PLAN.
5. SEE RCP PLANS AND SCHEDULE FOR CEILING HEIGHTS
6. GYPSUM BOARD FINISHING:
A. COMPLY'tVITH ASTM C 1340 STANDARD
SPECIFICATION AND FINISHING OF GYPSUM
BOARD; GA 214 RECOMMENDED LEVELS OF
GYP'S UM BOARD FINISH: AND GA 216.2000
APPLICATION AND FINISHING OF GYPSUM
BOARD.
B. PROVIDE GYPSUM BAORD MINI MUM FINISH
LEVELS MEETING THE CRITERIA
ESTABLISHED IN GA. 214AS FOLLOWS:
1. LEVEL 1 - GYPSUM lu<4"ALL BOARD
PERMANENTLY CONCEALED FROM VIEW.
2. LEVEL 2 • GYPSUM BOARD BEHIND AND
APPLIED WALL COVERING AND WALLS AND
CEILINGS IN MECHANICALAND EQUIPMENT
ROOMS.
3. LEVEL 4. GYPSUM WALL BOARD ON
INTERIOR WALLS FORALL TENANT
AREAS.
4. LEVEL 5 • GYPSUM' WALL BOARD CSI
FINISHED CEILINGS AND ALL COMN40N
AREA VALLS.
z� REFLECTED CEILING NOTES
1. TYPICAL CEILING - 2024" ACOUSTICAL TILE SIMILAR TO ARMSTRONG
ULTIMA #1911, NRC 0.75 OR BETTER, CAC 35 MIN., WHITE W` PRELUDE RAIL
SYSTEM.
2. FUR DOWN HARD CEILING. MAY BE STICK BUILT OR UTILIZE SIMILAR
SYSTEM TO ARMSTRONG SPEED SYSTEMS. CONTACT PHILIP CAITO
317-519-2829. LET ME KNOW IF THERE ARE SUGGESTIONS.
3. TRACK FOR ROOM PARTITION SYSTEM.
4. EXTENT COLUMNS ON END 4" ABOVE CEILING. SIMILAR TO BUILDING #3.
5. PROVIDE HOLD DOWN CLIPS AT ACT WITHIN 6' OF EXTERIOR DOORS.
6. HANGING ACOUSTICAL BAFFLE. CONTINUE GRID SYSTEM ABOVE.
7. NO NEW CEILING THIS ROOM. EXTEND WALLS TO DECK. FINISH EXISTING
GYP. BOARD.
8. RE-INFORCE CENTER AREA OF CEILING WITH (2) LAYERS "' PLYWOOD.
PROVIDE ±04'. SCREW THROUGH EXISTING GYPBOARD TO TRUSSES
ABOVE. DO NOT ANCHOR THROUGH RC CHANNEL.
9. MOUNT OUTLET ABOVE CEILING FOR CHRISTMAS LIGHTS. OUTLETS ARE
DESIGNATED WITH A C#_. CONTROL WITH WALL LIGHT SWITCH, SEE
ELECTRICAL PLANS.
10. ELEVATION TRANSITION SIMILAR TO ARMSTRONG AXIOM "TRANSITIONS"
LOCATION
STLE
LUMENS
MANUFACTURER
MODEL #
COST
TYPICAL BULB HOLDER
CFL, 10OW
L1
WITH GUARD
EQUIVALENT
L2
4k
6" RECESSED CAN, LED,
3000
CREE
LR6-18L-35K-GU24
DIMMABLE
1_3
=-
24"X24" GRID, LED,
CREE
ZR22C-32L-35K-10V-FD
MULTIPLE LEDS
L4
STORAGE ROOM AND IT ROOM LIGHT
6200 LM
CREE
ZR24C-40L-35K-10V-FD
3500K
LN4-34L-35K-10V
,5,000, 89
L5
CREE
LN -EC
Im/W
LN -CK -0 -AC
48" IN DIRECTSUSPENDIED STRIP
C
S -D L6-42 L-345 K
L5
6" RECESSED CAN, LED,
1250
CREE
SDL6T-M-SSC-WF
DIMMABLE
RBH24C-1
L7
NOT USED
(4) 1" SPOT LIGHTS ON 10'
NRS90-RAIL
L8
RAIL
NORA
NRE-850L30XBN
AT LOBBY SIGN
I (i
t�
SPOT I IGHT WITH GiMB E
ELITE LIGHTING
RI 461 650 rlI T��3nll 90
T-ILT�il7� l7'"C—�'Tl-o 'VT"l'J'V'
W-14
WIRE AND GLASS CYLINDER
EURO
L10
DECORATIVE CHANDELIER
CHANDELIER # #04030
ESIGN
DESIGN
DE
(LED BULBS)
SIMILAR TO: GALLERIA #GAL -PL -
DECORATIVE WALL WASH
L11
-
EDGE LIGHTING
SN -
LED
MODERN #56063 ODENSE -
ZUO
BLACK
L12
DECORATIVE CHANDELIER
(AMAZON)
(LED - MATCH BULB COLOR OF
ADJACENT CANS
LIGHT FIXTURE SCHEDULE
Scale: 1/8" = 1'-0"
PEDCOR DESIGN GROUP
Architecture / Project Manac
355 City Center Drive
Carmel. Indiana 46032
317.705.7979 (phone
317.705.7980 (fax)
Architect:
P� �G15 T E,?
00033126
STATE OF
By:
Developer:
P E D C O
DEVELOPMENT C
Project:
FM
Cn
z Q
LL
OWN
LLJ
LLICYS z
}
QuoW I LL
OLC)
UJ MJ Lr
Z0.00 cc
C'
cf)
COPYRIGHT 8 OWNERSHIP OF DOCUMEN
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES ANC
PROPERTY OF THE ARCHITECT AND PFDCCR DESIGN C
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. I'
AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE C
PUBLICATION IN DEROGATION OF COMMON LAW COPS I
INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVI
INFORMATION CONTAINED HEREIN CONSTITUTES THE
PUBLISHED WORK OF THE ARCHITECT, JAMES R. STUT.
PEDCOR DESIGN GROUP, LLC. NO PART OR %WOLE OF
THESE DRAWINGS, OR THE RESULTING BUILDING OR B
PORTIONS OF THE RESULTNG BUILDING OR BUILDING:
M;PL CATED, COPIED, EXHIBITED, PHOTOGRAPHED, PL
MODIFIED OR OTHERWISE DISTRIBUTED N ANS WAY W
SPECIFIC AND PRICK WRITTEN CONSENT OF THE ARC}
STUTZMAN AND PEDCOR DESIGN GROUP, LIC. O COP
JAMES R. STUTZMAN, AIA, Carr*, Indiana.
CONSTRUCTION
DOCUMENTS
Set Issue Date Sheet Is.
8/11/2017 8/11
Drawn By ChecF
BBP BI
Last Revision Date:
TATE RELEASE SET 8/
Sheet Title:
REFLECTED
CEILING PL/
08/30/2017 ASI #1 BID
SHEET.