Loading...
HomeMy WebLinkAbout046-90 Carmel Science & Tech Park Sanitary*EX. 8" (OUT) ® 830.60 T.C.=44.0 0+00 PROFILE ONE LOCATE EX, STUB AND CONSTRUCT MANHOLE OVER PIPE END. STA 0+00 MANHOLE STIR. # 401 6" NOTES: 1.CUTS SHOWN ARE APPROXIMATE, TAKEN FROM EXISTING GRADE TO INVERT OF PIPE. 2.ALL SANITARY MANHOLE CASTINGS SHALL BE: NEENAH R-1642 OR EQUAL W/CONCEALED PICK HOLES AND NOTE "SANITARY SEWER" ON LID. 3.EASEMENTS ARE SHOWN FOR REFERENCE ONLY AND DO NOT NECESSARILY DEPICT ACTUAL RECORDED INFORMATION. SEE RECORDED PLAT FOR EXACT INFORMATION. 4.THE CONTRACTOR WILL BE REQUIRED TO PROVIDE AS -BUILT DRAWINGS TO THE ACCEP-ING AGENCY TO CERTIFY THE ELEVATION AND SLOPE OF SANITARY SEWERS. SEWERS INSTALLED AT A GRADE LESS THAN REQUIRED BY THE AGENCY WILL NOT BE ACCEPTED. CONTRACTOR SHALL PROVIDE FOR PERIODIC AS -BUILT CHECKS ON THE SEWER DURING CONSTRUCTION TO ASSURE THAT DESIGN GRADE IS BEING MAINTAINED. PLAN ONE BUILDING #1 STA 0+90 5' 11 CLEANOUT I.E.=37.0 n EX. 8"(OUT) ® 28.98± 0+00 1+00 2+00 3+00 4+00 PROFILE TWO STA 3+00 ' (IN) 17.40 PLAN TWO APPROVAL PENDING NOT FOR CONSTRUCTION 801 CONGRESSIONAL BLVD. 0 SHEET: 6 REVISIONS PAUL i CRIPE, CIVIL ENGINEERING • INC.• • LAND SURVEYING 7172 GRAHAM ROAD • ARCHITECTURE INDIANAPOLIS, INDIANA 46250 • LAND PLANNING 317 8 2-6777 ENG CHK: DRAWN BY: SCALE: HORZ. 1" 30' VERT. 1 = 3' DATE: 5-10-90 CLIENT: TECHNOLOGY CENTER ASSOCIATESS DWG. TYPE FILE NUMBER TECH CHK: DRFTNG. CHK: DRAWING 11TLE: SANITARY PLAN & PROFILE JOB NUMBER DATE _ 1 0 SHEET: 6