HomeMy WebLinkAbout17100001.4ELECTRICAL ABBREVIATIONS A AMPS AFF ABOVE FINISHED FLOOR CO COMPANY CONTR CONTRACTOR DN DOWN DWG(S) DRAWING(S) EC ELECTRIC CONTRACTOR EDC ELECTRICAL DISTRIBUTION CENTER EM EMERGENCY EQUIP EQUIPMENT ETR EXISTING TO REMAIN EWC ELECTRIC WATER COOLER EX EXISTING FLA FULL LOAD AMPS FS FLOW SWITCH GC GENERALCONTRACTOR HP HORSE POWER MAX MAXIMUM MB MAIN BREAKER MC MECHANICAL CONTRACTOR MCA MIMIMUM CIRCUIT AMPS MFR MANUFACTURER MH MOUNTING HEIGHT MIN MINIMUM MLO MAIN LUG ONLY MOCP MAXIMUM OVER CURRENT PROTECTION MOD MOTOR OPERATED DAMPER MTD MOUNTED NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER PC PLUMBING CONTRACTOR PSI POUNDS PER SQUARE INCH RLA RUNNING LOAD AMPS RPM REVOLUTIONS PER MINUTE V VOLTS UON UNLESS OTHERWISE NOTED PANELBOARD SCHEDULE ABBREVIATIONS L LIGHTING R RECEPTACLE PN POWER NON -SEASONAL PW POWER WINTER MN MOTOR NON -SEASONAL MNI MOTOR NON -SEASONAL INTERMITTENT MS MOTOR SUMMER MW MOTOR WINTER KT KITCHEN FIRE PROTECTION SYMBOLS FIRE ALARM CONTROL PANEL FACP FIRE PULL BOX 8 HORN/STROBE ALARM COMBO PGFI HORN/STROBE ALARM COMBO WEATHER PROOF OUTLET - 220 FLOW SWITCH FS PIV TAMPER SWITCH SPECIAL EQUIPMENT COORDINATE W/SUPPLIER STROBE (� LJ' HOOD ANSUL SYSTEM CONNECTION a SMOKE DETECTOR 0 DUCT SMOKE DETECTOR -0SD HEAT DETECTOR DATA JACK PHONE COMBO CARBON MONOXIDE DETECTOR # DOOR ALARM SYMBOLS DOOR ALARM CONTROL PANEL DACP HINGE SIDE PLUNGER SWITCH 0 MAGNETIC LOCK WITH KEY PAD KP MAGNETIC LOCK WITH CARD READER CR FIRE ALARM SPECIFICATIONS 1. FIRE ALARM DEVICES ON THE PLANS ARE FOR INTENT ONLY, THE FIRE ALARM SYSTEM SHALL BE DESIGN AND BUILD BY A LICENSED FIRE PROTECTION CONTRACTOR WITH A MINIMUM OF 5 YEARS EXPERIENCE. SYSTEM SHALL BE FULLY ADDRESSABLE 2. DESIGN AND INSTALLATION SHALL CONFORM TO NFPA 72. SECTION 907 OF THE IBC. AND AS DIRECTED BY FIRE MARSHAL AS WELL AS ALL STATE AND LOCAL CODES. 3. PROVIDE FOR A FULLY FUNCTIONAL ADDRESSABLE CENTRAL BUILDING FIRE ALARM SYSTEM. 4. DRAWINGS ARE DIAGRAMMATIC. FINAL DESIGN SHALL BE BY MINIMUM NICET III LICENSED DESIGNER AND SHALL BE SUBMITTED AND APPROVED BY ALL AUTHORITIES HAVING JURISDICTION CONTRACTOR SHALL PROVIDE ALL REQUIRED DEVICES NEEDED FOR THE APPROVED SYSTEM REGARLESS OF WHAT IS INDICATED ON THESE INTENT PLANS AT NO ADDITIONAL COST TO THE OWNER. 5. FIRE ALARM CONTRACTOR SHALL SUBMIT THEIR PLANS FOR REVIEW AND APPROVAL BY AUTHORITY(S) HAVING JURISDICTION AND SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED APPROVALS AND PERMITS AND FOR PASSING ALL REQUIRED INSPECTIONS. 6. GENERAL SPECIFICATIONS INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING. a. SYSTEM SHALL BE EQUIPPED WITH AUTOMATIC EMERGENCY POWER WITH A MINIMUM 24 HOUR SUPPLY. b. ACTIVATION OF THE GENERAL ALARM MUST SOUND AN ALARM AND/OR VOICE EVACUATION THROUGH OUT THE BUILDING WITH A MINIMUM OF 65 dBA IN ALL AREAS. C. CABLING AND CONNECTION SHALL HAVE A MINIMUM 60 MINUTE FIRE RESISTANCE RATING. d. VISUAL STROBE DEVICES ARE REQUIRED AT ALL HORNS AND IN ALL PUBLIC AREAS. e. DETECTORS SHALL INCLUDE SMOKE DETECTORS (AREA AND DUCT). CARBON MONOXIDE DETECTORS AND HEAT DETECTORS AS REQUIRED f ALL ELECTRONIC DOOR LOCKS AND HOLD OPEN DEVICES SHALL BE INTERLOCKED TO RELEASE DOORS IN FIRE ALARM CONDITION. ELECTRICAL SYMBOLS DISCONNECT ET EXIT SIGNAGE 8 EXIT SIGNAGE WITH EMERGENCY HEADS PGFI EMERGENCY LIGHTING UNIT OUTLET - 220 EMERGENCY EXIT EGRESS LIGHT B FLUORESCENT CEILING MOUNTED STRIP LIGHT SPECIAL EQUIPMENT COORDINATE W/SUPPLIER FLUORESCENT WALL MOUNTED STRIP LIGHT FLOOR OUTLET WITH POWER, DATA AND PHONE RECESSED DOWN LIGHT O MOTOR LIGHT FIXTURE - ON NIGHT LIGHT CIRCUIT -� LIGHT FIXTURE - LAYIN FLUORESCENT DATA JACK PHONE COMBO LIGHT FIXTURE - SURFACE FLUORESCENT # LIGHT FIXTURE - FREE HANGING FLUORESCENT HOLDERS, REFLECTORS, BALLASTS. STARTERS AND LIGHT FIXTURE - WALL SCONCE AP EXTERIOR LIGHT FIXTURE - WALL PACK \ I PROVIDE WITH DAWN TO DUSK CONTROL E LIGHT FIXTURE - PENDANT O OUTLET - 4 WAY CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING OUTLET - DUPLEX 9 OUTLET - GROUND FAULT INTERRUPT PGFI OUTLET - GROUND FAULT INTERRUPT WEATHERPROOF 9GFI WP OUTLET - 220 JUNCTION BOX O SPECIAL EQUIPMENT COORDINATE W/SUPPLIER O FLOOR OUTLET WITH POWER, DATA AND PHONE FLR LOW VOLTAGE ONE LINE FOR ALL FIXTURES. LOW VOLTAGE TWO LINE -� DATA JACK PHONE COMBO -� # ANALOG PHONE LINE HOLDERS, REFLECTORS, BALLASTS. STARTERS AND WIRELESS ACCESS POINT AP PUSH BUTTON a BUZZER B® PHOTO CELL POWER POLE TIME CLOCK TC SWITCH SWITCH - 3 WAY 3 SWITCH - 4 WAY 4 SWITCH WITH DIMMER $D SWITCH WITH OCCUPANCY SENSOR 4 $OS CEILING MOUNTED OCCUPANCY SENSOR OS PANEL DESIGATION _� FTT CIRCUIT BREAKER NUMBERS X: XX.XX,XX ELECTRICAL SPECIFICATIONS 1. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL ENERGY CONSUMING OR PRODUCING ITEMS AND FOR ALL SWITCH GEAR. LOAD CENTERS AND PANEL BOARDS, SUBMITTALS SHALL BE DELINEATED WITH TAGS INDICATED ON PRINTS, CONTRACTORS NAME AND PROJECT NAME, CLEARLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES AND OPTIONS BEING PROVIDED, SUBMISSIONS SHALL BE IN PDF FORMAT. ALL EQUIPMENT AND ITEMS SHALL BE PER DESIGN BASIS OR APPROVED EQUAL ENGINEER RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE ITEM FOUND NOT EQUAL TO THE SPECIFIED ITEM AS DESIGNED. 2. CONTRACTOR SHALL FURNISH A TEMPORARY SERVICE FOR THE USE OF ALL TRADES DURING CONSTRUCTION AS REQUIRED BY THE GENERAL CONTRACTOR. REMOVE ALL TEMPORARY EQUIPMENT AS PERMANENT SERVICES BECOME AVAILABLE. 3. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES. LOCATIONS OR CODIFIED REQUIREMENTS. DRAWINGS SHOW GENERAL INTENT OF SYSTEMS. MODIFICATIONS IN ELECTRICAL SYSTEM ROUTING AND LOCATIONS AS REQUIRED TO MEET THE INTENT, SHALL BE PERFORMED WITHOUT ADDITIONAL COST TO OWNER. SECURE AND PAY FOR ALL REQUIRED PERMITS. 4. THE ELECTRICAL CONTRACTOR IS TO PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND CONTRACTOR'S SERVICES NECESSARY TO COMPLETE THE INSTALLATION OF SYSTEMS REQUIRED IN FULL CONFORMITY WITH APPLICABLE CODES AND ORDINANCES. THE FINISHED JOB SHALL BE FUNCTIONAL AND COMPLETE IN EVERY DETAIL INCLUDING ANY AND ALL SUCH ITEMS FOR A COMPLETE SYSTEM. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 5. ALL WORK SHALL IN BE IN FULL ACCORDANCE WITH 2009 INDIANA ELECTRICAL CODE (2008 NFPA 70), 2010 INDIANA ENERGY CODE (ASHRAE 90.1-2007), PERTINENT STATE, COUNTY, CODES AND ORDINANCE AND INDIANA AMENDMENTS, COORDINATE WORK WITH OTHER TRADES. ELECTRICAL CONTRACTOR SHALL BEAR ALL COSTS RESULTING FROM ANY NON COMPLIANCE WITH CODE REQUIREMENTS 6 MATERIALS AND EQUIPMENT SHALL BE NEW UNLESS INDICATED OTHERWISE, MATERIAL SHALL BEAR U.L. LABEL WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED AND LISTED BY U.L. MATERIALS AND EQUIPMENT SHALL CONFORM WITH THE LATEST ISSUES OF APPLICABLE TECHNICAL STANDARDS. 7. THE ELECTRICAL CONTRACTOR IS TO PROVIDE A COMPLETE SYSTEM OF LIGHTING, RECEPTACLES, AND POWER AS REQUIRED. VERIFY ALL VOLTAGES AND PHASE REQUIREMENTS WITH MECHANICAL CONTRACTOR'S EQUIPMENT PRIOR TO PERFORMING ANY WORK. 8 ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS BEFORE SUBMITTING A BID. NO EXTRAS WILL BE ENTERTAINED FOR CONTRACTORS FAILURE TO IDENTIFY EXISTING CONDITIONS AND ADJUST AS REQUIRED TO MEET DESIGN INTENT. 9. ALL CONDUIT COUPLINGS AND CONNECTIONS SHALL BE COMPRESSION TYPE AND MADE TO ENSURE POSITIVE GROUNDING CONTINUITY. MAKE CONNECTIONS TO EQUIPMENT SUBJECT TO VIBRATION WITH 18 INCHES OF FLEXIBLE WATERTIGHT CONDUIT WITH WATERTIGHT FITTINGS, PROVIDE FOR SUPPORT AND SECURING OF ALL CONDUIT AND EQUIPMENT. CONNECTIONS TO LIGHTING FIXTURES SHALL BE MADE WITH SIX (6) FEET OF FLEXIBLE CONDUIT FROM A BOX WITHIN TWO (2) FEET OF THE FIXTURE. SPLICE ALL WIRES ONLY IN ACCESSIBLE BOXES. ALL FIXTURE WHIPS TO BE FLEXIBLE METAL CONDUIT 1/2" MINIMUM SIZE WITH COMPRESSION CONNECTORS WITH INSULATED THROATS. WHIPS SHALL NOT EXCEED 6'. FIXTURE WHIPS TO BE SUPPORTED FROM BUILDING STRUCTURE. 10. ALL LIGHTING AND BRANCH CIRCUIT WIRING SHALL BE SOLID COPPER MINIMUM SIZE #12 AWG. 600V INSULATION, 75 DEG. C., TYPE THW OR THWN, NOT LESS THAN #12 AWG. ALL WIRE SERVING AS FEEDS TO DISTRIBUTION PANEL BOARDS OR INTEGRAL HORSEPOWER MOTORS SHALL BE EITHER STRANDED COPPER CONDUCTOR OR ASTM 8800 ALUMINUM AA -8000 SERIES, THESE SHALL BE SIZED NOT LESS THAN #10 AWG FOR COPPER AND NOT LESS THAN #8 AWG FOR ALUMINUM. EACH WITH MINIMUM 600V THW OR THWN INSULATION, 75 DEG. C. 11. EXPOSED WIRING SHALL BE IN EMT RACEWAY. EXTERIOR WIRING SHALL BE IN CONDUIT, CONCEALED WIRING SHALL BE IN EMT OR METAL CLAD CABLE WHERE ALLOWED BY CODE. 12. ALL LOW VOLTAGE WIRING IN PLENUM RATED CEILINGS OR EXPOSED IN ROOMS SHALL BE PLENUM RATED CABLE. 13, ALL CABLE SHALL BE NEW WIRE OF RECENT MANUFACTURE AND IN ACCORDANCE WITH THE LATEST STANDARDS OF IPCEA AND NEMA AS A MINIMUM 14, PANELBOARDS SHALL BE A DEAD -LOCK SAFETY TYPE, SURFACE OR RECESSED MOUNTED AS SHOWN, EQUIPPED WITH THERMAL -MAGNETIC MOLDED CASE CIRCUIT BREAKERS WITH FRAME AND TRIP RATINGS AS REQUIRED. TERMINALS FOR FEEDER CONDUCTORS TO THE PANELBOARD MAINS AND NEUTRAL SHALL BE U.L. LISTED AS SUITABLE FOR THE TYPE OF CONDUCTOR SPECIFIED. TERMINALS FOR BRANCH CIRCUIT WIRING. BOTH BREAKER AND NEUTRAL, SHALL BE U.L. LISTED AND CONNECTORS ELECTRICAL SPECIFICATIONS SHALL BE OF THE FULL COMPRESSION TYPE.THE PANELBOARD BUS ASSEMBLY SHALL BE ENCLOSED IN A STEEL CABINET. THE SIZE OF THE WIRING GUTTERS AND GAUGE OF STEEL SHALL BE IN ACCORDANCE WITH NEMA STANDARD PUBLICATION NO. PB -1971 AND U.L. STANDARDS NO. 67 FOR PANELBOARDS, CABINET SHALL BE FABRICATED FROM GALVANIZED STEEL OR EQUIVALENT RUST -RESISTANT STEEL FRONTS SHALL INCLUDE DOORS AND HAVE FLUSH, BRUSHED STAINLESS STEEL, CYLINDER TUMBLER -TYPE LOCKS WITH CATCHES AND SPRING LOADED DOOR PULLS. THE FLUSH LOCK SHALL NOT PROTRUDE BEYOND THE FRONT DOOR. ALL PANELBOARD LOCKS SHALL BE KEYED ALIKE. FRONTS SHALL HAVE ADJUSTABLE INDICATING TRIP CLAMPS WHICH SHALL BE CONCEALED WHEN THE DOORS ARE CLOSED. DOORS SHALL BE MOUNTED BY COMPLETELY CONCEALED STEEL HINGES, FRONTS SHALL NOT BE REMOVABLE WITH DOOR IN THE LOCATED POSITION. A CIRCUIT DIRECTORY FRAME AND TYPE WRITTEN CARD WITH A CLEAR PLASTIC COVERING SHALL BE PROVIDED ON THE INSIDE OF THE DOOR, THE DIRECTORY CARD SHALL PROVIDE A SPACE AT LEAST 1/4" HIGH X 3" LONG OR EQUIVALENT FOR EACH CIRCUIT, FRONTS SHALL BE OF CODE GAUGE. FULL FINISHED STEEL WITH RUST -INHIBITING PRIMER FACTORY FINISHED ENAMEL PAINT. 16, LOAD CENTERS SHALL BE UL LISTED AND MANUFACTURED IN ACCORDANCE WITH THE LATEST NEMA STANDARDS. CABINETS SHALL USE HINGED STYLE DOORS. MOUNT AT 6-6" TO TOP OF CABINET . 17. CIRCUIT BREAKERS SHALL BE QUICK -MAKE, QUICK -BREAK. THERMAL -MAGNETIC, TRIP INDICATING AND HAVE COMMON TRIP ON ALL MULTI -POLE BREAKERS. BRANCH CIRCUIT BREAKERS FEEDING CONVENIENCE OUTLETS SHALL HAVE SENSITIVE INSTANTANEOUS TRIP SETTINGS OF NOT MORE THAN 10 TIMES THE TRIP RATING OF BREAKER TO PREVENT REPEATED ARCING SHORTS RESULTING FROM FRAYED APPLIANCE CORDS, CONNECTION TO BUS SHALL BE BOLT ON. 18. CONTRACTOR TO OBTAIN MAXIMUM FAULT CURRENT AVAILABLE FROM THE UTILITY. CALCULATE THE FAULT CURRENT AVAILABLE AT THE PANEL, PANEL TO BE BRACED TO EXCEED MAXIMUM AVAILABLE FAULT CURRENT AND CIRCUIT BREAKERS ARE TO BE CAPABLE OF INTERRUPTING FAULT CURRENT. 19. MAXIMUM LOADING OF 20 AMP CIRCUITS SHALL NOT EXCEED 1750 WATTS. VOLTAGE DROP OF BRANCH CIRCUITS SHALL NOT EXCEED 3% AND FEEDER CIRCUITS SHALL NOT EXCEED 2%. SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS AND FLOORS AIR AND WATER TIGHT. FIRE STOP WHERE REQUIRED. 20. CONTRACTOR SHALL PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL ELECTRICAL PANELS.. DISCONNECTS. TRANSFORMERS AND MOTORS OVER 1 HP. FURNISH TYPEWRITTEN PANEL DIRECTORIES TO IDENTIFY ALL ELECTRICAL CIRCUITS BOTH NEW AND EXISTING. 21 VERIFY EXACT LOCATION, COLOR AND HEIGHTS OF ALL OUTLETS, RECEPTACLE;, LIGHT FIXTURES AND EQUIPMENT WITH OWNER'S REPRESENTATIVE PRIOR TO START OF WORK FURNISH GENERAL SERVICE DUPLEX'S, 15 AMP SWITCHES, 15/20 AMP GFICS, HEAVY DUTY DISCONNECTS. HVAC SSU SWITCHES. PANEL BOARDS, LOAD CENTERS, DISTRIBUTION PANELS ETC. AS REQUIRED. 22. DISCONNECT SWITCHES SHALL BE GENERAL DUTY, NEMA TYPE 1 FOR INDOOR SERVICE AND NEMA TYPE 3R FOR OUTDOOR SERVICE, SUITABLE FOR PADLOCKING. NUMBER OF POLES. RATINGS, FUSES (IF REQUIRED) SHALL BE AS INDICATED ON THE DRAWINGS 23. ALL GROUNDING OF ELECTRICAL SYSTEMS SHALL BE IN FULL COMPLIANCE WITH NEC SECTION 250. 24. DEVICES: A. CONVENIENCE RECEPTACLES SHALL BE MOUNTED 18" ABOVE FINISHED FLOOR (A.F.F.) TO BOTTOM UNLESS NOTED OTHERWISE, SWITCHES AND PUSHBUTTONS SHALL BE 42" A.F.F. TO BOTTOM UNLESS SPECIFIED OTHERWISE ON THE DRAWINGS. B. PRIOR TO ROUGH -IN E.C. SHALL VERIFY FINAL LOCATIONS AND COLORS OF ALL DEVICES WITH OWNER. C. INSTALL ALL DEVICES PARALLEL AND PERPENDICULAR TO ADJACENT WALL AND CEILING, FLUSH WITH SURROUNDING SURFACES AND FREE FROM ALL OBSTRUCTIONS. REWORKING OF EQUIPMENT INSTALLED IMPROPERLY SHALL BE AT THE CONTRACTOR'S EXPENSE. D. SWITCHES, BOXES, ETC., SHALL BE NEMA TYPE 1 CONSTRUCTION FOR IN[DOOR APPLICATIONS AND NEMA TYPE 3R CONSTRUCTION FOR OUTDOOR APPLICATIONS. E. SWITCHES SHALL MEET NEMA STANDARDS, COLOR SHALL BE BY ARCHITECT. SWITCHES SHALL BE EQUAL TO HUBBELL COMMERCIAL SPECIFICATION GRADE 20/15 AMPERES, SINGLE POLE, 125/277V. MULTI -POLE OR SPECIAL SWITCHING SHALL BE AS NOTED ON THE DRAWINGS. F. RECEPTACLES SHALL BE 125 VOLT, 15/20 AMPERES, DUPLEX. GROUNDED HUBBELL COMMERCIAL SPECIFICATION GRADE. SPECIAL RECEPTACLES SHALL BE AS NOTED ON THE DRAWINGS. G. MATCHING COVER PLATES SHALL BE PROVIDED FOR ALL RECEPTACLES AND SWITCHES. 23. LIGHTING FIXTURES: ELECTRICAL SPECIFICATIONS A. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIXTURES- MODEL NUMBERS, QUANTITY AND DISTANCE BETWEEN LIGHTING FIXTURE PER FLOOR PLANS, B. PRIOR TO ROUGH -IN E.C. SHALL VERIFY FIXTURE QUANTITY, MODELS, STYLE, TRIM, LENS, ETC WITH OWNER FOR ALL FIXTURES. C. PROVIDE LIGHTING FIXTURES COMPLETE WITH. BUT NOT NECESSARILY LIMITED TO. HOUSINGS, LAMPS, LAMP HOLDERS, REFLECTORS, BALLASTS. STARTERS AND WIRING. - D. FLUORESCENT -LAMP BALLASTS: PROVIDE ELECTRONIC FLUORESCENT -LAMP BALLASTS, CAPABLE OF OPERATING LAMP TYPES INDICATED WITH HIGH-POWER FACTOR, RAPIDSTART, AND LOW -NOISE FEATURES: TYPE 1, CLASS P, SOUND RATED A, AND WITH INTERNAL THERMAL PROTECTION, BALLASTS SHALL HAVE LESS THAN 10% THD AND CONTAIN NO PCBS. PROVIDE COLD WEATHER BALLASTS FOR ALL EXTERIOR FLUORESCENT FIXTURES. E. HIGH -INTENSITY -DISCHARGE -LAMP BALLASTS: PROVIDE HID LAMP BALLASTS, CAPABLE OF OPERATING LAMP TYPES WITH RATINGS INDICATED: REACTOR TYPE, HIGH POWER FACTOR. CORE AND COIL ASSEMBLY ENCAPSULATED IN NON -MELT RESIN, INSTALL CAPACITOR OUTSIDE BALLAST ENCAPSULATION FOR EASY FIELD REPLACEMENT AND ENCLOSED ASSEMBLY IN DRAWN ALUMINUM ALLOY HOUSING(S) UNLESS OTHERWISE SPECIFIED. F. FLUORESCENT LAMPS, PROVIDE 20,000 HR, T8, F3, 775 CRI LAMPS WITH A 3000K COLOR TEMPERATURE FOR EACH FLUORESCENT TROFFER. G. H.I.D. LAMPS: PROVIDE LAMPS OF BASE TYPE, GLASS ENVELOPE, AND SOURCE AS RECOMMENDED BY FIXTURE MANUFACTURE. ALL INTERIOR H.I.D. LAMPS MUST BE PHOSPHUR-COATED AND RATED 3000-3200K LAMPS USED IN OPEN FIXTURES MUST BE SAFETY -RATED 24. INSTALLATION OF LIGHTING FIXTURES A. INSTALL LIGHTING FIXTURES AT LOCATIONS AND HEIGHTS AS INDICATED, IN ACCORDANCE WITH FIXTURE MANUFACTURER'S WRITTEN INSTRUCTIONS, APPLICABLE REQUIREMENTS OF NEC. NECA'S "STANDARD OF INSTALLATION". NEMA STANDARDS. AND WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT LIGHTING FIXTURES FULFILL REQUIREMENTS. B. COORDINATE WITH OTHER ELECTRICAL WORK AS APPROPRIATE TO PROPERLY INTERFACE INSTALLATION OF INTERIOR LIGHTING FIXTURES WITH OTHER WORK. C. E.C. TO FASTEN FIXTURES SECURELY DIRECTLY TO BUILDING STRUCTURAL SYSTEM LIGHT TROFFERS SHALL BE SUPPORTED AT EACH CORNER OF FIXTURE BY WIRES OF SAME GAUGE AS HANGER WIRE FOR CEILING GRID. ATTACH EARTHQUAKE CLIPS TO GRID AS RECOMMENDED BY LIGHT MANUFACTURER. USE SCREWS IF REQUIRED BY MANUFACTURER. ATTACH THE WIRE TO THE STRUCTURE ABOVE. LIGHTS SHALL NOT BE SUPPORTED IN ANYWAY BY LAY -IN CEILING. D. FIXTURE LOCATIONS SHALL BE AT APPROXIMATE LOCATIONS AS SHOWN ON THE DRAWINGS FREE FROM ALL OBSTRUCTIONS, CLEAN ALL LIGHTING EQUIPMENT AFTER LIGHTING INSTALLATION AND GENERAL CONSTRUCTION IS COMPLETE. REPAIR ANY FIXTURES DAMAGED DURING CONSTRUCTIONS. E. PROVIDE NECESSARY MOUNTING FRAMES, SUPPORTS AND RELATED ITEMS REQUIRED TO 1?91 RE94YJ _A( I FIXTURES. SUPPORT FIXTURES I AND DUCTWORK. MAKE MODIFIC (A d rr coo > "G STRUCTURE AS REQUIRED TO IN �� _ aC M s 3 d t� MODIFICATIONS TO THE STRUCT cat G.Zm -.3 ".2.2 g ✓� r � THE STRUCTURAL INTEGRITY OF � C � T* z Z I 25. EQUIPMENT CONNECTIONS = a a H a Li A. ALL DEVICES AND EQUIPMENTS GROUNDED IN ACCORDANCE W11 a ' , ' a A d er tD B. ALL SOLID CONDUCTOR WIRES a 0 UNDER SCREW HEADS. STRAN N �; 3 v_ (A TERMINATED BY USING PUSH -11 zt. _z CONNECTORS FURNISHED WIT s a a oN, o - WITH COMPRESSION TYPE TER '�. ' �• O a V ^' r. TYPE TERMINATIONS ARE NOTa a 3 3 aj fDa'o C. NO MOTORS ARE TO BE SUPPLI a 3 UNLESS ITEMS REQUIRING A M s s mT- z=, THIS CONTRACTOR, THE CON c r; ALL STARTERS FOR ALL MOTO a eD F ma y Z Z THE CONTRACTOR SHALL CON �= m' c y ►- _ 7 EQUIPMENT IF &WHERE SHO OTHER -WISE SPECIFIED & ASS = �G `��^ o ARE IN GOOD RUNNING ORDS 3 n `^ °* M R° r _ D m a E.C. SHALL PROVIDE ALL COM a a Ra n - �_ o c M m 3 aCr7 MEANS OF DISCONNECT PER f Z - EQUIPMENT. -o tD n o .r 0 , O d a C T Z �- 26. LOW VOLTAGE a n 3• Z A. CONTRACTOR SHALL INSTALL FROM EACH LOW VOLTAGE R - ACCESSIBLE CEILING SPACE. LOW VOLTAGE WIRE TRAY OR HANGERS AND THEN TO MDF, HEAD -IN, PBX PUNCH DOWN, CONTROLLER ETC. B. E.C. SHALL COORDINATE WITH LOCAL PHONE AND CABLE PROVIDER AS CHOSEN BY OWNER AND PROVIDE RACEWAYS FOR BRINGING IN SERVICES AS REQUIRED C. ALL LOW VOLTAGE CABLE SHALL BE PLENUM RATED IN PLENUMS. D. ALL DATA CABLE SHALL BE CAT 5E UNLESS OTHER WISE NOTED. TERMINATE, LABEL AND TEST ALL WIRING. 27 CLOSE OUT A. PROVIDE MANUFACTURERS OPERATION AND MAINTENANCE MANUALS AND PROVIDE AS BUILT DRAWINGS. PROVIDE (1) TRAINING SESSION TO OWNER SELECTED PERSONNEL AS REQUESTED AND PROVIDE WARRANTY INFORMATION FOR ALL MANUFACTURERS WARRANTED EQUIPMENT. [ARCHITECTURE PUNNING 55 MONUMENT CIRCLE SUITE 1212 INDIANAPOLIS, INDIANA 46204 - 2910 PH : 317-348-1000 FAX 317-951-1213 WWW.ARCH ITU RACORP. CO GOODERUM & ASSOCIATES E MEP Engineer 874 Cheltenham Way Avon, IN 46123 P: 317.506.8151 F: 317.745.5761 E. gnaengineering@aol.com THIS DRAWING AND ALL INFORMATION PROPERTY OF ARCHITURA CORPORAT' CONFIDENTIAL AND ITS SUBMISSION 1 TO MEET OFFICIAL REGULATORY RE, FOR OTHER PURPOSES IN CONNEC' PROJECT IS NOT TO BE CONSTRUED IN DEROGATION OF COMMON LAW OTHER RESERVED RIGHTS. THIS DR PART OF IT NOR ANY INFORMATION MAY BE COPIED, EXHIBITED, RE FURNISHED TO OTHERS NOR MAY PI MADE OF ANY ARTICLE FABRICATED i FROM THIS DRAWING WITHOUT WRi OF ARCHITURA CORPORATION. ® COPYRIGHT 2014 ARCHITURA C SIGNATURE SEAL I❑I IIiO cq No. '=1020039`. STATE OF IA DATE: 09/12/ COMMISSION: 17100 DRAWING BY: CHECKED BY: REVISIONS MICHIGAN RC SELF STORAI MICHIGAN ROAD CARMEL, IN 46032 SHEET TITLE SHEET NUMBER