Loading...
HomeMy WebLinkAbout17100001.6KEYPAD STATION I I I I I I I I I I I I I I I I I ( I I I I I I I I I NOTE PROVIDE ELECTRICAL INSTALLATION ACCORDING TO GATE MANUFACTURER'S WRITTEN INSTRUCTIONS COORDINATE SAWCUT REQUIREMENTS WITH GATE SYSTEM INSTALLER I I I I i I VEHICLE SENSOR LOOP IN SAWCUT IN PAVING MOTORIZED GATE F 1 I I I I I I I Imo---- VEHICLE SENSOR LOOP IN SAWCUT IN PAVING I I I I I I I I I I I I I I I I II II GATE OPERATOR L T J 1"C Y__� 1 "C KEYPAD STATION —JP� — —� ------ lll III III III III I (2) 2"C FROM GATE OPERATOR TO TELECOM ROOM REFER TO SHEET EA.3 SII �I CONDUIT WITH POWER FOR GATE OPERATOR GATE ELECTRICAL ROUGH -IN DETAIL SCALE: NONE EXTEND CONCEAL WIRING TO LIGHT F DETAIL AT JUNCTION BOX SCALE: NONE GHT TO POST 0 MATCH POLE :EL POST BEYOND _ _ I ,NDUIT BODIES — OX AND CONDUIT CH POST CONDUIT FROM POWER SOURCE G NIPPLE INTO POST VERIFY ND) LOW VOLTAGE CONDUITS —/ NDUITS CONC.PAVEMENT Llti`E NEUTRAL NOTES: 1, HAND -OFF -AUTOMATIC SELECTOR SWITCH IN COVER OF CONTACTOR 2, TIMECLOCK (TC) - SIMILAR TO TORK #DG100A. 3. PHOTOELECTRIC CONTROL (PE) - PARAGON #CW201-00 OR EQUAL. 4. COIL OF PHOTOCELLTIMECLOCK CONTROLLED LIGHTING CONTACTOR. (ELECTRICALLY HELD, 120VAC UNLESS NOTED OTHERWISE), 5. COIL OF PHOTOCELL CONTROLLED LIGHTING CONTACTOR. REFER TO CONTACTOR SCHEDULE FOR ADDITIONAL REQUIREMENTS. (120VAC UNLESS NOTED OTHERWISE) 6, CONTACTS FOR CONTROL OF LIGHTING CIRCUITS, QUANTITY OF CONTACTS NECESSARY TO CONTROL ALL PHOTOCELL/CONTACTOR CONTROLLED BRANCH CIRCUITS PER PLANS, 7, FIELD COORDINATE FINAL TIME CLOCK SETTINGS AND SCHEDULE WITH OWNER. EXTERIOR BRANCH CIRCUITRY CONTROL DIAGRAM SCALE: NONE 12"x12"x6" NEMA 3R LOW VOLTAGE CONDUITS GATE OPERATOR J -BOX SCALE: NONE GATE OPERATOR JUNCTION BOX 0 "v , d. A I I e m_T SECTION SEAL TOP WITH 114" PLATE KEYPAD AND INTERCOM. VERIFY WIRING REQUIREMENTS Z O Q �m 0� �w C7 2 I 4"X 4" X 114" PTD. STEEL POLE A I I - 7 4 ELEVATION KEYPAD/DETAIL. SCALE: NONE PROVIDE 12" CONCRETE FOOTING GRIND ALL WELDS SMOOTH, PRIME AND POWDER COAT PAINT C111 tura ARCHITECTURE PLANNING DESIGN CREATION 55 MONUMENT CIRCLE SUITE 1212 INDIANAPOLIS, INDIANA 46204 — 2910 PH 317-348-1000 FAX 317-951-1213 WWW.ARC H ITU RACORP. COM GOODERUM & ASSOCIATES ENGINEERING MEP Engineer 874 Cheltenham Way IL Avon, IN 46123 P: 317.506.8151 F. 317.745.5761 (QA E: gnaengineering@aol.com THIS DRAWING AND ALL INFORMATION ON IT IS THE PROPERTY OF ARCHITURA CORPORATION. IT IS CONFIDENTIAL AND ITS SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR OTHER PURPOSES IN CONNECTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT OR OTHER RESERVED RIGHTS. THIS DRAWING NOR ANY PART OF IT NOR ANY INFORMATION CONCERNING IT MAY BE COPIED, EXHIBITED, REPRODUCED OR FURNISHED TO OTHERS NOR MAY PHOTOGRAPHS BE MADE OF ANY ARTICLE FABRICATED OR ASSEMBLED FROM THIS DRAWING WITHOUT WRITTEN CONSENT OF ARCHfTURA CORPORATION. ® COPYRIGHT 2014 ARCHITURA CORPORATION SIGNATURE SEAL 09-12-2017 unIII nuu"uu, GOX 7.�;.p q, No. =% `102003951x- Q ` STATE OF � ,,VD NP,, n " �, „ DATE: 09/12/17 COMMISSION: 17100 DRAWING BY: CHECKED BY: REVISIONS MICHIGAN ROAD SELF STORAGE MICHIGAN ROAD CARMEL, IN 46032 SHEET TITLE SHEET NUMBER E003