Loading...
HomeMy WebLinkAbout17100001.14Luminaire Schedule Symbol Qty Label Arrangement Description 3 J SINGLE COLUMBIA 01 E:5 E 5 E 5 J FROM BLDG E Lum. Watts 60 BUILDING "C" ELECTRICAL PLAN SCALE: 1/8" = 1'-0" Luminaire Schedule Symbol Qty 10 10 GENERAL NOTES - 1 . OTES: 1. REFERENCE SHEET E-001 FOR LEGENDS, ABBREVIATIONS, SPECIFICATIONS AND NOTES. 2. ALL EXIT SIGNS, EMERGENCY LIGHTING UNITS, AND NIGHT LIGHTS SHALL HAVE UNSWITCHED CONDUCTOR. 3. FIRE ALARM SYSTEM DEVICES ARE SHOWN FOR REFERENCE ONLY, FIRE ALARM SYSTEM Lum. Lumens LLF SHALL BE DESIGN AND BUILD, SEE E001 FOR 5208 0.884 DESIGN AND BUILD SPECIFICATIONS. 5. REFERENCE LIGHTING VENDOR SHOP DRAWINGS FOR OCCUPANCY SENSOR ZONING. 6. LIGHT FIXTURE TYPES AS FOLLOWS: A) TYPE X1 SIMILAR TO LITHONIA #LXCW RW EL B) TYPE RH SIMILAR TO LITHONIA #ELA. C) LIGHT FIXTURE WITH 'E' LETTER SUFFIX ADDED TO THE LIGHT FIXTURE DESIGNATION INDICATES FIXTURE WITH INTEGRAL BATTERY INVERTER. 7. TYPE RH LIGHTS SHALL BE EMERGENCY ON ONLY. 8 ALL EXTERIOR LIGHTING SHALL BE PHOTOCELL CONTROLLED WITH TIMED OVERRIDE. REFERENCE DETAIL #5, SHEET E002 FOR ADDITIONAL INFORMATION. KEY NOTES: 1O E C. SHALL INTERLOCK WIRING BETWEEN EXHAUST AND THERMOSTAT, FAN AND THERMOSTAT SHALL BE PROVIDED BY M C., 2O REMOTE KEYPAD SYSTEM. PROVIDE RECEPTACLE FOR MAG LOCK AND ROUGH IN FOR KEY PAD. COORDINATE LOCATION OF SYSTEM CONTROLLER WITH OWNER AND PROVIDE POWER AS REQUIRED. 3� PROVIDE TIMER SWITCH FOR STORAGE ROOM LIGHTING FIXTURE, MOUNT AT 42'' AFF. TYPICAL, OALL BRANCH CIRCUITS FOR THIS OUT BUILDING ARE FED PANEL E IN BUILDING E. PROVIDE MEANS OF DISCONNECT ON EACH CIRCUIT AT ENTRY POINT IN OUT BUILDING, Label Arrangement Description Lum. Watts Lum. Lumens LLF i D SINGLE SINGLE COLUMBIA COLUMBIA #CSR4-232-E-PAF 120 5208 0.884 60 5208 0.884 Lrl i I JJ :4 A.40 E a ONL E:7 500 1 �✓� i I J J J OW E:7 D E:6 EC� E:7 DE off/ D O O O D ® � E,5 E:5 E:5 E:5 X1 P 4 I - ... _...... _.....— I BUILDING "B" ELECTRICAL PLAN SCALE: 1/8" = 1'-0" E:7 DE ow D W E:7 I E:7 D FROM J BLDG E QEF RH _ E:7 DE 4 E:6 E7 E:5JQ PCHFTECTURE PLANNING DESIGN CREATION 55 MONUMENT CIRCLE SUITE 1212 INDIANAPOLIS, INDIANA 46204 - 2910 PH 317-348-1000 FAX 317-951-1213 WWW.ARCH ITU RACORP. COM GOODERUM & ASSOCIATES ENGINEERING MEP Engineer 874 Cheltenham Way Avon, IN 46123 P: 317.506.8151 F: 317.745.5761 E: gnaengineering@aol.com THIS DRAWING AND ALL INFORMATION ON IT IS THE PROPERTY OF ARCHITURA CORPORATION. IT IS CONFIDENTIAL AND ITS SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR OTHER PURPOSES IN CONNECTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT OR OTHER RESERVED RIGHTS. THIS DRAWING NOR ANY PART OF IT NOR ANY INFORMATION CONCERNING IT MAY BE COPIED, EXHIBITED, REPRODUCED OR FURNISHED TO OTHERS NOR MAY PHOTOGRAPHS BE MADE OF ANY ARTICLE FABRICATED OR ASSEMBLED FROM THIS DRAWING WITHOUT WRITTEN CONSENT OF ARCHITURA CORPORATION. m COPYRIGHT 2014 ARCHITURA CORPORATION SIGNATURE SEAL 09-12-2017 No, =.3= __tz10200395 Q' STATE OF At TAMP, ell DATE: 09/12/17 COMMISSION: 17100 DRAWING BY: CHECKED BY: REVISIONS MICHIGAN ROAD SELF STORAGE MICHIGAN ROAD CARMEL, IN 46032 SHEET TITLE SHEET NUMBER E401