HomeMy WebLinkAbout17100001.15SYMBOLS CONTROL SYMBOLS THERMOSTAT OT THERMOSTAT IN LOCK BOX OT SENSOR SO CARBON MONOXIDE SENSOR CO '° NITROGEN OXIDE SENSOR NO ROUND MOTORIZED DAMPER M RECTANGULAR MOTORIZED DAMPER M DUCT SYMBOLS COMBUSTION AIR CFM CUBIC FEET PER MINUTE DEG F DEGREES FARENHEIT SHEET METAL DUCT WIDTH BY DEPTH W/D LINED SHEET METAL DUCT FREE AREA WIDTH BY DEPTH. _ W/D­7 SQUARE SHEET METAL 90 DOUBLE THICKNESS TURNING VANES REQUIRED �J RADIUS SHEET METAL 90, R=1.5"D 1:z� SQUARE SHEET METAL 90 PROVIDE WITH DOUBLE THICKNESS TURNING VANES. E�]] TURNING VANES DOUBLE THICKNESS ENTERING AIR WET BULB ROUND HIGH EFFICIENCY BRANCH DUCT TAKE OFF ON ROUND DUCT. ELECTRICAL CONTRACTOR ROUND TAP BRANCH DUCT TAKE OFF ON ROUND DUCT. EXHAUSTFAN HIGH EFFICIENCY BRANCH DUCT TAKE OFF ON RECTANGULAR. ELECTRIC WALL HEATER STANDARD ROUND TAP BRANCH DUCT TAKE OFF ON ROUND DUCT. ELECTRIC WATER COOLER MANUAL VOLUME DAMPER LOCKING WITH SHAFT ELECTRIC REHEAT COIL CENTERED SQUARE TO ROUND TRANSITION EXTERNAL STATIC PRESSURE ECCENTRIC SQUARE TO ROUND TRANSITION EXPANSION TANK RECTANGULAR CENTERED DUCT TRANSISTION ED RECTANGULAR ECCENTRIC DUCT TRANSITION FAN COIL UNIT FULL BODY ROUND TEE FITTING FIRE DAMPER OR FLOOR DRAIN EQUIPMENT SYMBOLS FIRE AND SMOKE DAMPER FPM FEET PER MINUTE AIR COOLED CONDENSING UNIT ® ACCU FT FOOT ROOF MOUNTED INTAKE/EXHAUST HOOD RECTANGULAR IH RH ROOF MOUNTED INTAKE/EXHAUST HOOD ROUND IH • RH HORIZONTAL FURNACE OR FC WITH DRAIN PAN FC F HORIZONTAL AIR COOLED CONDENSING UNIT AC CEILING MOUNTED EXHAUST FAN EF ELECTRIC WALL HEATER �] EWH DIFFUSER SYMBOLS INCH IR INFRA -RED LAY -IN SUPPLY AIR DIFFUSER LAVATORY LAY -IN RETURN AIR REGISTER OR GRILLE LEAVING AIR TEMPERATURE LINEAR OR SLOT DIFFUSER LIQUID LINE SOLENOID VALVE DIRECT DUCT MOUNTED REGISTER LINEAR SLOT DIFFUSER BOOT MOUNTED REGISTER El DIFFUSER TAG X-# MARK XXX CFM ABBREVIATIONS AFF ABOVE FINISH FLOOR ACCU AIR COOLED CONDENSING UNIT AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT CO CLEAN OUT CW COLD WATER DOMESTIC CA COMBUSTION AIR CFM CUBIC FEET PER MINUTE DEG F DEGREES FARENHEIT DB DRY BULB 0 ROUND EA EACH EG EXHAUST GRILLE OR REGISTER EADB ENTERING AIR DRY BULB EAWB ENTERING AIR WET BULB EC ELECTRICAL CONTRACTOR EF EXHAUSTFAN EWH ELECTRIC WALL HEATER EWC ELECTRIC WATER COOLER ERC ELECTRIC REHEAT COIL ESP EXTERNAL STATIC PRESSURE ET EXPANSION TANK F FURNACE FCU FAN COIL UNIT FD FIRE DAMPER OR FLOOR DRAIN FD/SD FIRE AND SMOKE DAMPER FPM FEET PER MINUTE FPVAV FAN POWERED VAV BOX FT FOOT FSK FOIL SCRIM VAPOR BARRIER GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE H HOOD HWR HOT WATER RETURN DOMESTIC HWS HOT WATER SUPPLY DOMESTIC IN INCH IR INFRA -RED LAV LAVATORY LAT LEAVING AIR TEMPERATURE LLSV LIQUID LINE SOLENOID VALVE LS LINEAR SLOT DIFFUSER MAN MANUAL MFR MANUFACTURER MBH 1000 BTU MC MECHANICAL CONTRACTOR MCC MOTOR CONTROL CENTER MS MOP SINK OA OUTSIDE AIR PC PLUMBING CONTRACTOR PRV PRESSURE RELEIF VALVE PSI POUNDS PER SQUARE INCH PD PRESSURE DROP PDU POOL DEHUMIDIFICATION UNIT PRV PRESSURE RELEIF VALVE PSI POUNDS PER SQUARE INCH PTAC PACKAGE TERMINAL AIR CONDITIONER RA RETURN AIR RJ ROOF JACK, MATCH ROOF COLOR RPZB REDUCED PRESSURE ZONED BACKFLOW RPM REVOLUTIONS PER MINUTE RTU ROOF TOP UNIT SA SUPPLY AIR SAF SUPPLY AIR FAN SCRN GALVNIZED WIRE SCREEN, 1/2X1/2 SP STATIC PRESSURE SAN SANITARY SEWER SD STORM DRAIN ST STORAGE TANK SK SINK TCC TEMPERATURE CONTROL CONTRACTOR TMV THERMOSTATIC MIXING VALVE TSP TOTAL STATIC PRESSURE UR URINAL UON UNLESS OTHERWISE NOTED VAV VARIABLE AIR VOLUME BOX VTR VENT THROUGH ROOF WC WALL CAP WC WATER CLOSET WH WATER HEATER WIC WALK IN COOLER WIF WALK IN FREEZER MECHANICAL SPECIFICATIONS 1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE BID IN STRICT ACCORDANCE WITH DESIGN BASIS EQUIPMENT AND MATERIALS. PROJECT DOES ENCOURAGE COMPETITIVE PRICING AND ALLOWS FOR SUBSTITUTIONS OF EQUIPMENT AND MATERIALS AS ALTERNATE DEDUCTS TO BASIS OF DESIGN BIDS. LIST ALL SUBSTITUTIONS ALONG WITH DEDUCTS OFFERED ON BID. ENGINEER RESERVES THE RIGHT TO REJECT SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ITEMS LISTED IN DESIGN BASIS. 2. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL ENERGY CONSUMING OR PRODUCING ITEMS AND FOR ALL DUCT ACCESSORIES. INSULATION. VAV BOXES. REGISTERS. GRILLES. DIFFUSERS AND LOUVERS. SUBMITTALS SHALL BE DELINEATED WITH TAGS INDICATED ON PRINTS, CONTRACTORS NAME. PROJECT NAME. CLEARLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE IN PDF FORMAT. ALL EQUIPMENT AND ITEMS SHALL BE PER DESIGN BASIS OR APPROVED EQUAL. ENGINEER RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE ITEM. 3. CONTRACTOR SHALL BE RESPONSIBLE TO VISIT THE SITE TO EXAMINE ALL CONDITIONS THAT MAY IN ANY WAY AFFECT THE EXECUTION OF HIS WORK. HE SHALL ALSO EXAMINE THE DRAWINGS AND SPECIFICATIONS FOR OTHER BRANCHES OF WORK MAKING REFERENCE TO THEM FOR DETAILS OF EXISTING BUILDING CONDITIONS. NO EXTRAS WILL BE ALLOWED FOR FAILURE TO INCLUDE ALL REQUIRED WORK IN THE BID. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 4. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. DRAWINGS SHOW GENERAL INTENT OF SYSTEMS. M.C. SHALL PROVIDE AND PAY FOR ALL REQUIRED PERMITS. 5. UPON COMPLETION OF THE MECHANICAL INSTALLATION, DEMONSTRATE TO THE ENGINEER AND THE OWNER'S SATISFACTION THAT THE SYSTEMS HAVE BEEN INSTALLED IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS AND APPLICABLE CODES. DEMONSTRATE THE DYNAMIC OPERATION OF EACH SYSTEM. VERIFY PROPER OPERATION OF EQUIPMENT, FILTERS ARE CLEAN AND COMPONENTS OF THE SYSTEM ARE INSTALLED AND ADJUSTED IN FULL ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 6. ALL WORK SHALL BE IN FULL ACCORDANCE WITH 2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE). INDIANA ENERGY CODE (ASHRAE 90.1-2007) PERTINENT STATE, COUNTY.. CITY CODES AND ORDINANCES AND INDIANA AMENDMENTS 7. MECHANICAL CONTRACTOR SHALL ENSURE EMPLOYEES ARE MEETING AND DOCUMENTING ALL OSHA AND JOB SPECIFIC SAFETY REQUIREMENTS AS REQUIRED BY LAW AND BY CONTRACT. PERSONAL PROTECTIVE EQUIPMENT SHALL BE PROVIDED AND UTILIZED AS REQUIRED, MECHANICAL CONTRACTOR SHALL PAY ALL FINES LEVIED BY OSHA FOR FAILURE TO COMPLY WITH OSHA REQUIREMENTS. DUCTWORK 1. ROUND DUCT SHALL BE LINDAB OR EQUAL GALVANIZED STEEL CONFORMING TO ASTM STANDARDS A653 AND A924 GASKETED SPIRAL DUCTING WITH NO SEALER. EDPM RUBBER GASKET SHALL BE U.L. CLASSIFIED RATING OF FLAME SPREAD 0 AND SMOKE DEVELOPED 5 IN ACCORDANCE WITH ASTM STANDARD E84 -91A SMACNA LEAKAGE CLASS 3. FITTINGS SHALL BE MANUFACTURED USING ONE OR MORE OF THE FOLLOWING CONSTRUCTION METHODS: OVERLAPPED EDGES STITCH WELDED ALONG THE ENTIRE LENGTH OF THE FITTING. STANDING SEAM GORE LOCKED AND INTERNALLY SEALED, BUTTON PUNCHED AND INTERNALLY SEALED. ELBOWS 3 -INCH THROUGH 12 -INCH DIAMETER WILL BE DIE STAMPED AND CONTINUOUSLY STITCH WELDED. 3. PROVIDE SHEET METAL 90 FOR ALL TURNS DO NOT USE FLEXIBLE DUCT FOR GREATER THAN 45 DEG CHANGES IN DIRECTION. PROVIDE MANUAL BALANCING DAMPERS FOR ALL SUPPLY AIR RUNS. ROUND DAMPERS SHALL BE SECURED ON BOTH SIDES OF DUCT AND SHALL CONTAIN LOCKING HANDLE. SPIRAL DUCTS SHALL USE SPIRAL STYLE DAMPERS WITH FULL WIDTH SHAFT AND NYLON BEARINGS AT EACH END. RECTANGULAR DUCTS SHALL USE MULTI OR SINGLE BLADE WELDED FRAMED DAMPERS WITH JACK SHAFTS AND LOCKING HANDLE. INSTALL NYLON RIBBON ON ALL DAMPER HANDLES TO AID IN LOCATION OF DAMPER. 4 CONCEALED AREAS: INSULATED FLEXIBLE DUCTING FOR STRAIGHT CONNECTIONS SHALL NOT EXCEED 7 FEET. FLEXIBLE DUCT EQUAL TO FLEXIBLE DUCT CLASS 1 AIR DUCT, DOUBLE LAMINATED POLYESTER FILM ON STEEL WIRE REINFORCING, INSULATED WITH SCRIM REINFORCED METALIZED POLYESTER OUTER FIRE RETARDANT JACKET. R-4.2 FOR CONDITIONED SPACES AND R-6.0 FOR ANY SPACES OUTSIDE BUILDING THERMAL ENVELOPE. 5. RECTANGULAR DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA LOW PRESSURE DUCT STANDARDS. +/- 1.0" W.C. FROM ASTM A 653/A 653M G-90 COATED GALVANIZED SHEET STEEL. SEAMS SHALL BE PITTSBURGH CONSTRUCTION, NO BUTTON PUNCH OR SNAP LOCK SEAMS ARE ACCEPTABLE. SEAL ALL TRANSVERSE AND LONGITUDINAL SEAMS WITH WATER BASED DUCT SEALER, SEAL CLASS B. GAUGE AND JOINT CLASSIFICATIONS ACCEPTABLE ARE AS FOLLOWS, ALL SECTION LENGTHS ARE 48" MAXIMUM, REFER TO SMACNA RIGIDITY TABLES FOR GAUGES ON LONGER SECTIONS IF REQUIRED: < 12" 26 GAUGE, FLAT S AND DRIVE 12"-24" 24 GAUGE. FLAT S AND DRIVE 25"-34" 22 GAUGE. STANDING S AND FLAT DRIVE 34"-40" 22 GAUGE, STANDING S AND STANDING DRIVE >40" REFER TO SMACNA FOR STANDARDS. 6. DUCT HANGERS: COMPLY WITH SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE." CHAPTER 5, "HANGERS AND SUPPORTS." PROVIDE GALVANIZED MINIMUM 22 GAUGE 1" WIDE STRAP TO HANG RECTANGULAR DUCTWORK SMALLER THAN 30" WIDE. DUCT HANGERS FOR RECTANGULAR SHEET METAL DUCTS 30" AND LARGER SHALL BE TRAPEZE STYLE USING UNI -STRUT AND 3/8" OR 1/2" ROD, PROVIDE GRIPPLE, DURODYNE OR EQUAL CABLE HANGERS FOR HANGING ROUND DUCTWORK. SUPPORT ALL HANGERS FROM STRUCTURE PER SMACNA STANDARDS. HANGERS FOR SPIRAL DUCTS GREATER THAN 28" IN DIAMETER SHALL BE HUNG WITH ROD AND DUCT CLAMP. FLEXIBLE DUCTING SHALL BE SUPPORTED USING MINIMUM 2" WIDE NYLON STRAP. ALL INTERVALS ARE PER SMACNA. DUCT ACCESSORIES 1. COORDINATE WITH ARCHITECTURAL DRAWINGS AND PROVIDE FIRE AND FIRE AND SMOKE DAMPERS AT FIRE RATED ASSEMBLY PENETRATIONS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE. DUCT INSULATION 2. ALL DUCT INSULATION MATERIALS SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES AND LOCAL AUTHORITIES HAVING JURISDICTION. DUCT WRAP SHALL BE FIBERGLASS MATERIAL PER ASTM C-411.ASTM C-1104,ASTM C665, ASTM C-1338. ASTM E-84, UL723, NFPA 90A,CAN/ULC S102-1188,ASTM C1290, ASTM C553, ASTM C1136. 3. INSULATION: INSTALL ALL INSULATION IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS IN A TIGHT AND NEAT MANOR. NO SAGGING, FRAYED OR TORN INSULATION WILL BE EXCEPTED, UNLESS OTHERWISE NOTED ON PLANS DUCTWORK SHALL BE INSULATED ,4S FOLLOWS: FIRE STOPPED OR CAULKED WATER AND AIR TIGHT. 2. REFRIGERATION PIPING: A. SYSTEMS 5 TONS OR LESS, MANUFACTURED REFRIGERANT LINE SETS: ANNEALED -COPPER SUCTION AND LIQUID LINES FACTORY CLEANED, DRIED, PRESSURIZED WITH NITROGEN, SEALED, AND WITH SUCTION LINE INSULATED. PROVIDE IN STANDARD LENGTHS FOR INSTALLATION WITH MINIMUMAL JOINTS. USE WROUGHT -COPPER FITTINGS BRAZED WITH 15% SILVER SIL-FLOS BRAZING ROD. B. INSULATION, SUCTION AND ALL DUCTLESS SPLIT OR VRF LINES: MINIMUM 1/2" THICK WALL INSULATION SHALL BE A FLEXIBLE, CLOSED -CELL ELASTOMERIC PIPE INSULATION. AP ARMAFLEX OR AC ACCOFLEX. ADHESIVE SHALL BE ARMAFLEX 520, 520 BLACK OR 520 BLV ADHESIVE THE INSULATION MUST CONFORM TO ASTM C534 GRADE 1, TYPE I ARMAFLEX AND BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. (3/8" WALL WILL NOT BE ACCEPTED). C. ALL INSULATION EXPOSED TO OUTDOORS SHALL BE EITHER PVC LAGGED OR SHALL BE PAINTED WITH ARMA-FINISH FR UV PROTECTING PAINT. D. LINES SHALL BE RUN KINK FREE AND GENERALLY CONTINUOUS AND AT 90 DEGREE ANGLES TO STRUCTURE. AVOID JOINTS WHEN POSSIBLE. ALL REQUIRED JOINTS SHALL BE MADE IN ACCESSIBLE LOCATIONS OR M.C. SHALL PROVIDE ACCESS PANELS AS NEEDED. ALL BENDS SHALL BE MADE WITH LONG RADIUS FITTINGS OR WITH MECHANICAL BENDING TOOL TO PROVIDE SMOOTH LONG RADIUS TURNS. SUPPORT ALL PIPING WITHOUT CRUSHING OR DEPRESSING INSULATION. USE REFRIGERATION STYLE CUSH CLAMPS MOUNTED TO STRUT, DO NOT LAY PIPING ON STRUCTURAL BUILDING MEMBERS SLEEVE ALL PENETRATIONS AND SEAL WATER TIGHT. E. PRESSURE TEST, TRIPLE EVACUATE AND PREPARE ALL PIPING IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 3. CONDENSATE PIPING SA- OFFICE SYSTEM: 1-1/2" FIBERGLASS A. DUCT WRAP WITH FSK FACING, 75 #/FT3 MINIMUM APPLIED R-3.5 INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS REQUIREMENTS, SARA- EXPOSED IN STORAGE AREAS: NONE REQUIRED. RA EQUIPMENT RA PLENUMS AND FURNACE BOXES; DUCT LINER FOR DUCTS SHALL BE MINIMUM 1" THICK, 1-1/2 # DENSITY PER CU. FT., HAVING MAT FACED OR MONOLITHIC CONSTRUCTION WITH SKIN SMOOTH MICROBIAL SURFACE TO WITHSTAND VELOCITIES TO 4000 FPM. INSULATION SHALL FIT SNUGLY AGAINST THE INTERIOR DUCT SURFACES, AND BE FASTENED TO THE DUCT WITH A 50% HEAVY COAT OF RECOMMENDED ADHESIVE AND METAL FASTENERS WHICH DO NOT PIERCE THE DUCT, SPACED ON 12" CENTERS. ALL EXPOSED EDGES OF THE INSULATION SHALL BE COATED WITH MANUFACTURED RECOMMENDED ADHESIVE EA- NONE REQUIRED UNLESS NOTED ON PLANS. PROVIDE TRAPS BUILT FROM INDIVIDUAL FITTINGS ON ALL EVAPORATOR DRAIN PANS MINIMUM DEPTH 1.5 TIMES BLOWER BLOCKED TIGHT STATIC PRESSURE. ALL TRAPS SHALL BE CONSTRUCTED WITH PVC 90S (MANUFACTURED RUNNING TRAP FITTINGS ARE NOT ACCEPTABLE). PROVIDE ALL TRAPS WITH CLEAN OUTS AND REMOVABLE CAPS AS NEEDED FOR MAINTAINING LINES. B. HVAC CONTRACTOR SHALL COORDINATE CONDENSATE DISPOSAL POINTS WITH P.0 HVAC CONTRACTOR IS RESPONSIBLE FOR PIPING FROM EVAPORATOR COILS TO DISPOSAL POINT. P.C. IS RESPONSIBLE FOR STAND PIPES, FLOOR AND HUB DRAINS AS NEEDED. C. POLYVINYL CHLORIDE DRAIN, WASTE AND VENT PIPE (PVC) SCHEDULE 40 MINIMUM SIZE 3/4". INSULATED IN RETURN AIR PLENUMS. D. PROVIDE CONDENSATE PUMPS AS REQUIRED WITH HIGH LEVEL SHUT DOWN SWITCHES INTERLOCKED TO A/C UNITS E. PITCH ALL PIPING MINIMUM4" PER FOOT. SUPPORT PIPING AT MINIMUM 5'-0'' INTERVALS. SECURE FINAL CONNECTION AT SEWER WITH MINIMUM 1-1/2" AIR GAP CONNECTION. F. INSULATE ALL PIPING IN RA PLENUMS AND ABOVE HARD CEILINGS WITH MINIMUM 3/8" WALL ARMAFLEX INSULATION 4. FIRE STOPPING. A. OA- ALL: 1-1/2" FIBERGLASS DUCT WRAP WITH FSK FACING, 75 #/FT3 MINIMUM APPLIED R-3.5 INSTALLED IN STRICT B ACCORDANCE WITH MANUFACTURERS REQUIREMENTS, C. CHECK TEST AND START UP REQUIREMENTS 1. LABEL ALL MAJOR PIECES OF EQUIPMENT WITH LAMACOID PLASTIC, BLACK WITH WHITE LETTERS. SIZE TO BE CONSISTENT WITH EQUIPMENT BEING LABELED, LENGTH AND WIDTH VARY FOR REQUIRED LABEL CONTENT. THERMOSTAT AND SENSOR LABELS SHALL BE ADJUSTED TO PROVIDE ESTHETIC APPEARANCE. 2. PROVIDE AIR BALANCE BY CONTRACTOR. CONTRACTOR SHALL BALANCE SUPPLY, RETURN. OUTSIDE, RELIEF AND EXHAUST AIR SYSTEMS IN ACCORDANCE WITH CURRENT SMACNA. NEEB OR AABC STANDARDS TO DESIGN VALUES AND PROVIDE WRITTEN REPORT TO ARCHITECT. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL DEVICES. DRIVES, SHEAVES, MOTOR CHANGES AND REWORK AS REQUIRED TO MEET DESIGN REQUIREMENTS. 791 E 3. TEMPERATURE CONTROL WORK SHALL BE THE RESPONSIBILITY OF THE HVAC CONTRACTOR. F PROVIDE ALL COMPONENTS INCLUDING T/S, T/S WIRE (PLENUM RATED IN RA PLENUMS), SWITCHES, ACTUATORS ETC, AS REQUIRED FOR A COMPLETE SYSTEM. 1. PIPING SLEEVES, INTERIOR OR EXTERIOR ABOVE GRADE; GALVANIZED -STEEL ROUND OR RECTANGULAR SLEEVES OR PVC -PIPE SLEEVES, VERIFY, WITH FIRE AUTHORITIES HAVING JURISDICTION, THAT PVC MATERIALS ARE ALLOWED FOR SLEEVES. ALL SLEEVES SHALL- BE SEALED AND FIRE STOPPING SYSTEMS SHALL BE IN FULL COMPLIANCE WITH SECTIONS 713 OF THE IBC AND SECTION 607 OF THE IMC. CONTRACTOR SHALL MAKE REFERENCE TO ARCHITECTURAL PLANS AND PROVIDE ALL REQUIRED FIRE STOPPING, CONTRACTOR SHALL PROVIDE FULL SUBMITTAL INDICATING METHODS OF CONSTRUCTION AND UL LISTING OF EACH SYSTEM, DUCTS AND AIR TRANSFER OPENINGS. PENETRATIONS OF FIRE -RESISTANCE -RATED WALLS BY DUCTS THAT ARE NOT PROTECTED WITH DAMPERS SHALL COMPLY WITH SECTIONS 713.2 THROUGH 713.3.3 OF THE IBC. PENETRATIONS OF HORIZONTAL ASSEMBLIES NOT PROTECTED WITH A SHAFT AS PERMITTED BY EXCEPTION 4 OF SECTION 708 2, AND NOT REQUIRED TO BE PROTECTED WITH FIRE DAMPERS BY OTHER SECTIONS OF THE IBC CODE. SHALL COMPLY WITH SECTIONS 713.4 THROUGH 713.4.2.2 OF THE IBC. DUCTS AND AIR TRANSFER OPENINGS THAT ARE PROTECTED WITH DAMPERS SHALL COMPLY WITH SECTION 716. FIRE DAMPERS, SMOKE DAMPERS. COMBINATION FIRE/SMOKE DAMPERS AND CEILING RADIATION DAMPERS LOCATED WITHIN AIR DISTRIBUTION AND SMOKE CONTROL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 607 OF THE IMC. AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND LISTING. ACCESS DOORS SHALL BE PERMITTED IN CEILINGS OF FIRE -RESISTANCE -RATED FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES PROVIDED SUCH DOORS ARE TESTED IN ACCORDANCE WITH ASTM E 119 OR UL 263 AS HORIZONTAL ASSEMBLIES AND LABELED BY AN APPROVED AGENCY FOR SUCH PURPOSE. ALL ACCESS DOORS SHALL BE PROVIDED BY TRADE MAKING PENETRATIONS. chltura ARCHITECTURE PLANNING DESIGN CREATION 55 MONUMENT CIRCLE SUITE 1212 INDIANAPOLIS, INDIANA 46204 - 2910 PH 317-348-1000 FAX 317-951-1213 WWW .ARCH ITU RAC O R P. C O M GOODERUM & ASSOCIATES ENGINEERING MEP Engineer 874 Cheltenham Way Q Avon. IN 46123 P: 317.506.8151 F: 317.745.5761 E: gnaengineering@aol.com THIS DRAWING AND ALL INFORMATION ON IT IS THE PROPERTY OF ARCHITURA CORPORATION. IT IS CONFIDENTIAL AND ITS SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR OTHER PURPOSES IN CONNECTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT OR OTHER RESERVED RIGHTS. THIS DRAWING NOR ANY PART OF IT NOR ANY INFORMATION CONCERNING IT MAY BE COPIED, EXHIBITED, REPRODUCED OR FURNISHED TO OTHERS NOR MAY PHOTOGRAPHS BE MADE OF ANY ARTICLE FABRICATED OR ASSEMBLED FROM THIS DRAWING WITHOUT WRITTEN CONSENT OF ARCHTURA CORPORATION. m COPYRIGHT 2014 ARCHITURA CORPORATION SIGNATURE SEAL 09-12-2017 ���ouG 11 wwwulnrpgp Wi qQ: No, G3' 10200395; Q' STATE OF DATE: 09/12/17 COMMISSION: 17100 DRAWING BY: CHECKED BY: REVISIONS MICHIGAN ROAD SELF STORAGE MICHIGAN ROAD CARMEL, IN 46032 SHEET TITLE HVAC SYMBOLS, ABBREVIATIONS AND SPECIFICATIONS. SHEET NUMBER M001