HomeMy WebLinkAbout17100001.22SYMBOLS ABOVE FINISH FLOOR PIPING LINETYPES AIR COOLED CONDENSING UNIT CONDENSATE DRAIN CND COLD WATER DOMESTIC CW COMPRESSED AIR CA GREASE/OIL/DIRT DRAIN LINE GL GAS NATURAL OR PROPANE GAS HEATING WATER RETURN DOMESTIC HWR HEATING WATER SUPPLY DOMESTIC HW ROOF DRAIN RD SANITARY SEWER SAN STORM DRAIN SD PIPING SYMBOLS EXHAUST AIR OR EACH REFERENCE. COORDINATE ALL INTERLOCKS AS EXHAUST GRILLE OR REGISTER ANCHOR/HANGER ENTERING AIR DR`( BULB BALL VALVE ENTERING AIR WET BULB BUTTERFLY VALVE ELECTRICAL CONTRACTOR CHECK, SWING VALVE --(�- DROP E EXPANSION JOINT ELECTRIC WATER COOLER FLANGED CONNECTION - i �- FLEXIBLE PUMP CONNECTION EXTERNAL STATIC PRESSURE GAS METER GM GATE VALVE FURNACE GLOBE VALVE H� I BALANCING VALVE FIRE DAMPER OR FLOOR DRAIN "P" TRAP J PENDANT STYLE FIRE SUPPRESSION HEAD O PIPE GUIDE FAN POWERED VAV BOX PITCH DOWN IN DIRECTION OF ARROW FOOT PLUG VALVE I PRESSURE GAUGE Q GAS REGULATOR FRI RISER HOOD RUN OUT OFF BOTTOM OF MAIN T RUN OUT OFF TOP OF MAIN HOT WATER SUPPLY DOMESTIC TEE OFF SIDE OF MAIN INCH TEST PLUG INFRA -RED THERMOMETER LAVATORY UNION LEAVING AIR TEMPERATURE LS WATER METER O "Y" STRAINER MFR MANUFACTURER MBH ABBREVIATIONS AFF ABOVE FINISH FLOOR ACCU AIR COOLED CONDENSING UNIT AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BOD BOTTOM OF DUCT CO CLEAN OUT CW COLD WATER DOMESTIC CA COMBUSTION AIR CFM CUBIC FEET PER MINUTE DEG F DEGREES FARENHEIT DB DRY BULB 0 DIAMETER EA EXHAUST AIR OR EACH REFERENCE. COORDINATE ALL INTERLOCKS AS EXHAUST GRILLE OR REGISTER EADB ENTERING AIR DR`( BULB EAWB ENTERING AIR WET BULB EC ELECTRICAL CONTRACTOR EF EXHAUSTFAN EWH ELECTRIC WALL HEATER EWC ELECTRIC WATER COOLER ERC ELECTRIC REHEAT COIL ESP EXTERNAL STATIC PRESSURE ET EXPANSION TANK F FURNACE FCU FAN COIL UNIT FD FIRE DAMPER OR FLOOR DRAIN FD/SD FIRE AND SMOKE [CAMPER FPM FEET PER MINUTE FPVAV FAN POWERED VAV BOX FT FOOT FSK FOIL SCRIM VAPOR BARRIER GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE H HOOD HWR HOT WATER RETURN DOMESTIC HWS HOT WATER SUPPLY DOMESTIC IN INCH IR INFRA -RED LAV LAVATORY LAT LEAVING AIR TEMPERATURE LS LINEAR SLOT DIFFUSER MAN MANUAL MFR MANUFACTURER MBH 1000 BTUH MC MECHANICAL CONTRACTOR MCC MOTOR CONTROL CENTER MS MOP SINK OA OUTSIDE AIR PC PLUMBING CONTRACTOR PRV PRESSURE RELEIF VALVE PSI POUNDS PER SQUARE INCH PD PRESSURE DROP PDU POOL DEHUMIDIFICATION UNIT PRV PRESSURE RELEIF VALVE PSI POUNDS PER SQUARE INCH PTAC PACKAGE TERMINAL AIR CONDITIONER RA RETURN AIR RJ ROOF JACK. MATCH ROOF COLOR RPZB REDUCED PRESSURE ZONED BACKFLOW RPM REVOLUTIONS PER MINUTE RTU ROOF TOP UNIT SA SUPPLY AIR SAF SUPPLY AIR FAN SP STATIC PRESSURE SAN SANITARY SEWER SD STORM DRAIN ST STORAGE TANK SK SINK TCC TEMPERATURE CONTROL CONTRACTOR TMV THERMOSTATIC MIXING VALVE TSP TOTAL STATIC PRESSURE UR URINAL LION UNLESS OTHERWISE NOTED VAV VARIABLE AIR VOLUME BOX VTR VENT THROUGH ROOF WC WALL CAP WC WATER CLOSET WH WATER HEATER WIC WALK IN COOLER WIF WALK IN FREEZER PLUMBING SPECIFICATIONS GENERAL 1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE BASE BID IN STRICT ACCORDANCE WITH DESIGN BASIS EQUIPMENT AND MATERIALS. PROJECT DOES ENCOURAGE COMPETITIVE PRICING AND ALLOWS FOR SUBSTITUTIONS OF EQUIPMENT AND MATERIALS AS ALTERNATE DEDUCTS TO BASIS OF DESIGN BIDS. LIST ALL SUBSTITUTIONS ALONG WITH DEDUCTS OFFERED ON BID. ENGINEER RESERVES THE RIGHT TO REJECT SUBSTITUTIONS FOUND NOT TO BE EQUAL TO ITEMS LISTED IN DESIGN BASIS. 2. PRIOR TO PROCUREMENT CONTRACTOR SHALL SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL ENERGY CONSUMING OR PRODUCING ITEMS AND FOR ALL PLUMBING FIXTURES, VALVES, DRAINS. CLEAN OUTS. PIPING, PIPING ACCESSORIES, INSULATION AND PIPING HANGERS. SUBMITTALS SHALL BE DELINEATED WITH TAGS INDICATED ON PRINTS, CONTRACTORS NAME. PROJECT NAME. CLEARLY INDICATE ALL MODEL NUMBERS AND ALL ACCESSORIES AND OPTIONS BEING PROVIDED. SUBMISSIONS SHALL BE IN PDF FORMAT.ENGINEER RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE ITEM. 3. CONTRACTOR SHALL BE RESPONSIBLE TO VISIT THE SITE TO EXAMINE ALL CONDITIONS THAT MAY IN ANY WAY AFFECT THE EXECUTION OF HIS WORK HE SHALL ALSO EXAMINE THE DRAWINGS AND SPECIFICATIONS FOR OTHER BRANCHES OF WORK MAKING REFERENCE TO THEM FOR DETAILS OF EXISTING BUILDING CONDITIONS, NO EXTRAS WILL BE ALLOWED FOR FAILURE TO INCLUDE ALL REQUIRED WORK IN THE BID. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 4. THE DRAWINGS IN THIS SECTION ARE DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE EXACT QUANTITIES, LOCATIONS OR CODIFIED REQUIREMENTS. DRAWINGS SHOW GENERAL INTENT OF SYSTEMS. P.C. SHALL PROVIDE AND PAY FOR ALL REQUIRED PERMITS. 5. UPON COMPLETION OF THE PLUMBING INSTALLATION, DEMONSTRATE TO THE ENGINEER AND/OR THE OWNER'S SATISFACTION THAT THE SYSTEMS HAVE BEEN INSTALLED IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS AND APPLICABLE CODES, DEMONSTRATE THE DYNAMIC OPERATION OF EACH SYSTEM. VERIFY PROPER OPERATION OF EQUIPMENT, FILTERS ARE CLEAN AND COMPONENTS OF THE SYSTEM ARE INSTALLED AND ADJUSTED IN FULL ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. 6. PLUMBING WORK SHALL BE COMPLETE IN EVERY DETAIL AND ALL MISCELLANEOUS ITEMS OF MATERIAL AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED. SHOWN OR REASONABLY IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUIRED. WHEN SUCH ADJUSTMENTS ARE NECESSARY FOR PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIALS ENTERING INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE. 7. ALL WORK SHALL BE IN FULL ACCORDANCE WITH 2012 INDIANA PLUMBING CODE (INTERNATIONAL PLUMBING CODE 2006). 2010 INDIANA ENERGY CODE (2007 ASHRAE 90.1), 2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE) AND ALL PERTINENT STATE, COUNTY, CITY CODES AND ORDINANCES WITH INDIANA AMENDMENTS. 8. PLUMBING CONTRACTOR SHALL VISIT THE SITE AND VIEW ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. NO EXTRAS WILL BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT 9. PLUMBING CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 10. PLUMBING CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL WATER. GAS, STORM AND SEWER UTILITY ROUGH -INS AND SHALL CONSULT WITH THE CIVIL PLANS AND WITH LOCAL UTILITY COMPANY(S) PROVIDING ALL MATERIALS AND LABOR AND PAYING ALL COSTS NOT BORNE BY THE LOCAL UTILITY COMPANY(S) FOR INSTALLATION OF SERVICES INCLUDING SECURING AND PAYING FOR ALL REQUIRED PERMITS. 11. PLUMBING CONTRACTOR SHALL ENSURE EMPLOYEES ARE MEETING AND DOCUMENTING ALL OSHA AND JOB SPECIFIC SAFETY REQUIREMENTS AS REQUIRED BY LAW AND BY CONTRACT. PERSONAL PROTECTIVE EQUIPMENT SHALL BE PROVIDED AND UTILIZED AS REQUIRED, MECHANICAL CONTRACTOR SHALL PAY ALL FINES LEVIED BY OSHA FOR FAILURE TO COMPLY WITH OSHA REQUIREMENTS. 12. ALL PLUMBING MATERIALS INSTALLED IN RETURN AIR PLENUMS SHALL BE INSTALLED OR COVERED WITH MATERIALS AS REQUIRED TO PROVIDE FLAME RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50. PRIOR TO ROUGH -IN CONSULT WITH M.C. TO VERIFY ALL LOCATIONS OF RETURN AIR PLENUMS. 13. FURNISH AND INSTALL ACCESS PANELS FOR ALL CONCEALED EQUIPMENT, PIPING VALVES, CLEANOUTS, ETC. ACCESS PANELS SHALL BE OF SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING CLEARANCE AND ACCESS. 14, PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED CUTTING AND PATCHING INCLUDING SAW CUTTING AND PATCHING OF EXISTING FLOORS AS REQUIRED TO ACCEPT NEW FLOORING. MECHANICAL ROOMS SHALL BE DONE WITH MECHANICAL SEALS LIKE LINK SEAL OR EQUAL. ALL EXTERIOR PENETRATIONS OF BUILDING WALLS OR ROOFS SHALL BE SLEEVED AND SEALED WATER TIGHT 3. PROVIDE BELLOWS TYPE WATER HAMMER ARRESTERS, STAINLESS STEEL CASHING AND BELLOWS, 250 PSI, INSTALL PER PDI STANDARD WH2O1. PIPING 1. ALL EXPOSED SUPPLY PIPES AND METAL TRIM IN CONNECTION WITH THE FIXTURES SHALL BE CHROME PLATED RED BRASS OR BRONZE, PROVIDE CHROME PLATED STOP VALVES IN ALL SUPPLIES TO ALL FIXTURES. CAULK ALL FIXTURES WITH WATERPROOF SILICONE CAULK, TRAPS SHALL HAVE CLEANOUT PLUGS. INSTALL ONE PIECE CHROME ESCUTCHEON PLATE WITH SET SCREW AT WALL PENETRATIONS. 2. WASTE AND VENT PIPING MAINS SHALL BE PITCHED AT 1/8" PER FOOT. LATERAL BRANCHES SHALL BE PITCHED 1/4" PER FOOT TOWARD THE SANITARY SEWER MAIN. THEY SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH THE CURRENT INDIANA PLUMBING CODE AND TESTED PER AUTHORITY HAVING JURISDICTION. 3 VERIFY LOCATION, DEPTH AND SIZE OF SANITARY SEWER CONNECTION POINTS. CONNECT AS REQUIRED. OUTSIDE SEWER SHALL BE INSTALLED WITH MINIMUM OF T-0" COVER. COORDINATE CONNECTIONS WITH SITE CONTRACTOR AND LOCAL UTILITY 4. ALL OUTSIDE WATER PIPING SHALL BE COVERED WITH A MINIMUM OF 52". 5. ALL PIPING INTERIOR PENETRATIONS OF WALLS AND FLOORS SHALL BE SLEEVED, SEALED AND FIRE RATED WHERE REQUIRED. ALL EXTERIOR UNDERGROUND PENETRATIONS OF BUILDING WALLS OR FOUNDATIONS INTO BASEMENTS OR PLUMBING INSULATION 1. ALL PIPING INSULATION MATERIALS SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES ANQ LOCAL AUTHORITIES HAVING JURISDICTION. ALL PVC PIPING LOCATED IN RETURN AIR PLENUM SPACES OR EXPOSED SHALL BE INSULATED. 2. INSULATION: INSTALL ALL INSULATION IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS IN A TIGHT AND NEAT MANOR. NO SAGGING, FRAYED OR TORN INSULATION WILL BE EXCEPTED. UNLESS OTHERWISE NOTED ON PLANS PIPING SHALL BE INSULATED AS FOLLOWS: HW FLEXIBLE UNICELLULAR PIPE INSULATION, ASTM C534, TYPE 1. MINIMUM THICKNESS ;HALL BE 1/2" FOR PIPE SIZES 1-1/4" AND LESS AND SHALL BE 1" FOR 1-1/2" AND C3REATER. CHECK TEST AND START UP REQUIREMENTS 1. CLOSE OUT: PROVIDE MANUFACTURERS OPERATION AND MAINTENANCE MANUALS AND AS BUILT DRAWINGS. PROVIDE (1) TRAINING SESSION TO OWNER SELECTED PERSONNEL AS REQUESTED. 2 FILL SYSTEMS WITH FRESH WATER AND INSPECT ALL CONNECTIONS FOR LEAKAGE. FIRE ALL WATER HEATERS AND START ALL PUMPS. CORRECT ALL LEAKS AND VIBRATIONS AS REQUIRED. hitura ARCHITECTURE PLANNING DESIGN CREATION 55 MONUMENT CIRCLE SUITE 1212 INDIANAPOLIS, INDIANA 46204 - 2910 PH 317-348-1000 FAX 317-951-1213 WWW.AR C H ITU RAC O R P. C O M GOODERUM & ASSOCIATES ENGINEERING MEP Engineer 874 Cheltenham Way p Avon, IN 46123 P: 317.506.8151 F. 317.745.5761 E: gnaengineering@aol.com THIS DRAWING AND ALL INFORMATION ON IT IS THE PROPERTY OF ARCHITURA CORPORATION. IT IS CONFIDENTIAL AND ITS SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR OTHER PURPOSES IN CONNECTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT OR OTHER RESERVED RIGHTS. THIS DRAWING NOR ANY PART OF IT NOR ANY INFORMATION CONCERNING IT MAY BE COPIED, EXHIBITED, REPRODUCED OR FURNISHED TO OTHERS NOR MAY PHOTOGRAPHS BE MADE OF ANY ARTICLE FABRICATED OR ASSEMBLED FROM THIS DRAWING WITHOUT WRITTEN CONSENT OF ARCHITURA CORPORATION. O COPYRIGHT 2014 ARCHITURA CORPORATION SIGNATURE SEAL 09-12-2017 °,°°���y'sTE'�'DF•pG, = =`10200395; lz Q STATE OF 7�6 "ON/till 111111m \\ DATE: 09/12/17 COMMISSION: 17100 DRAWING BY: CHECKED BY: REVISIONS MICHIGAN ROAD SELF STORAGE MICHIGAN ROAD CARMEL, IN 46032 SHEET TITLE PLUMBING SYMBOLS, ABBREVIATIONS AND SPECIFICATIONS. SHEET NUMBER Pool 6. NO PLUMBING PIPING SHALL PASS DIRECTLY OVER EQUIPMENT ELECTRICAL PANELS OR DISTRIBUTION CABINETS. PRIOR TO ROUGH IN COORDINATE WITH E.C. 1. PROVIDE EQUIPMENT AS SHOWN ON EQUIPMENT SCHEDULES AND PLAN NOTES. SUBSTITUTIONS TO 4. DIELECTRIC UNIONS SHALL BE USED TO CONNECT LISTED EQUIPMENT SHALL BE AT RISK OF DISSIMILAR METALS OR METAL PIPING SHALL HAVE CONTRACTOR. SUBSTITUTIONS SHALL ONLY BE METAL CONNECTIONS ON EACH END THREADED TO ALLOWED IF ITEMS ARE EQUAL IN ALL ASPECTS. MATCH THE= ADJACENT PIPING. METAL COMPONENTS SHALL BE SEPARATED BY A NYLON 2. PROVIDE SUBMITTALS TO ELECTRICIAN AS INSULATOR TO PREVENT CURRENT FLOW BETWEEN REQUIRED FOR COORDINATION OF ALL REQUIRED DISSIMILAR METALS. UNIONS SHALL BE SUITABLE ELECTRICAL POWER WIRING, INCLUDE WIRING FOR THE SYSTEM OPERATING PRESSURES AND DIAGRAMS AND CABLING REQUIREMENTS FOR TEMPERATURE WELD TYPE: ASTM A-234. REFERENCE. COORDINATE ALL INTERLOCKS AS NEEDED. PROVIDE SINGLE POINT CONNECTION KITS 5. PIPING SLE EVES; INTERIOR OR EXTERIOR ABOVE AS NEEDED. GRADE; GALVANIZED -STEEL -PIPE SLEEVES OR PVC -PIPE SLEEVES. VERIFY, WITH FIRE AUTHORITIES 3. INSTALL ALL EQUIPMENT IN FULL ACCORDANCE HAVING JURISDICTION, THAT PVC MATERIALS ARE WITH MANUFACTURERS RECOMMENDATIONS AND ALLOWED FOR SLEEVES. BELOW GRADE, ALL, CLEARANCE REQUIREMENTS. PROVIDE ALL MECHANICAL GALVANIZED -STEEL PIPE SLEEVE REQUIRED MOUNTING OR HOUSEKEEPING PADS. SYSTEM LIKE LINK -SEAL. ALL SLEEVES SHALL BE G.C. SHALL PROVIDE LEVEL GRADE FOR EXTERIOR FIRE STOPPED OR CAULKED. EXTERIOR SLEEVES MOUNTED EQUIPMENT. P.C. SHALL PROVIDE ALL SHALL PROVIDE WATER/AIR TIGHT PENETRATION HOISTING AND RIGGING NEEDED TO SET ALL SYSTEM. PLUMBING EQUIPMENT. 6. PROVIDE HANGERS PER MSS AND IPC STANDARDS 4. ALL EQUIPMENT SHALL BE INSTALLED AS NEEDED BASED ON PIPING TYPES AND SIZES TO PREVENT OBJECTIONABLE NOISE AND/OR VIBRATION. P.C. SHALL PROVIDE VIBRATION PADS. SPRING ISOLATORS. ATTENUATORS AND 7 PIPING MATERIALS UNLESS OTHERWISE NOTED ON ACCESSORIES AS NEEDED. THE PLANS SHALL BE AS FOLLOWS: 5. PROVIDE ALL BLOCKING, HANGERS, SHELVES. GAS ABOVE GRADE, 2" AND SMALLER; BLACK 'S BRACKETS ETC. AS REQUIRED TO INSTALL ALL STEEL SCHEDULE 40 TYPE E ORPIPE PLUMBING EQUIPMENT. GRADE B: ASTM A53 / A53M, Al 05 OR Al 20 WITH THREADED ENDS; FITTINGS SHALL 2. INSTALL WATER HEATERS IN ACCORDANCE WITH BE MALLEABLE IRON THREADED FITTINGS NFPA-70. AND THE NATIONAL ELECTRICAL CODE. ASTM 816.3 CLASS 150. PROVIDE BRASS DRAIN VALVE. 3/4" RELIEF VALVE WATER BELOW GRADE: HDPE (HIGH DENSITY AND COLD WATER DIP TUBE. INSTALL HEATERS PER POLYETHYLENE) 200 PSIG, SDIR-9 NSF MANUFACTURES INSTALLATION INSTRUCTIONS. APPROVED FOR POTABLE DRINKING PROVIDE SHUT-OFF VALVES FOR SERVICE WORK. WATER. 3. THERMOSTATS ON WATER HEATER SHALL NOT BE WATER COPPER TUBING (INSIDE UTILITY ROOM): USED FOR LIMITING HOT WATER TEMPERATURES. ASTM B 88. TYPE'L' HARD WATER TUBE PRAWN TEMPER. WITH CAST -COPPER P.C. SHALL PROVIDE MIXING VALVES FOR HOT SOLDER -JOINT FITTINGS: ANSI B16.18. OR WATER TO ALL FAUCETS ACCESSIBLE TO WROUGHT -COPPER SOLDER JOINT OCCUPANTS. MIXING VALVE SYSTEMS SHALL LIMIT FITTINGS: ANSI B16.22 WATER TEMPERATURE AT FAUCETS TO 110 DEG F. OR LESS. WATER PEX WATER PIPING (FRONT OFFICE FIXTURES RESTROOMS &bREAK ROOM): SHALL BE WIRSBO OR UPONOR TUBING ASTM F876 AND F877, BLUE FOR COLD AND RED FOR 1. REFERENCE FIXTURE SCHEDULES ON PLANS AND HOT AND RE -CIRCULATION FITTINGS PROVIDE ALL REQUIRED CARRIERS BLOCKING, SHALL BE UPONOR ProPEX SYSTEM C69300 HANGERS. TAIL PIECES, TRAPS, RISERS, BRASS FITTINGS ASTM F877, F1960. ESCUTCHEONS, GRIDS, PUTTY. GASKETS, CAULKING, MANIFOLDS: ProPEX TYPE L TO ASTM F877 ETC. AS REQUIRED TO INSTALL ALL PLUMBING WITH BRASS BALL VALVES. FIXTURES. 2. REVIEW SUBMITTALS FOR ALL OWNER PROVIDED SEWER POLYVINYL CHLORIDE SEWER PIPE (PVC): EQUIPMENT AND PROVIDE ANY REQUIRED ASTM D2665 SOLID DRAIN WASTE AND ACCESSORIES AS NEEDED FOR A COMPLETE VENT OR ASTM F 891 CELLULAR CORE INSTALLATION. P.C. SHALL BE RESPONSIBLE TO 5CHEDULE 40 WITH PVC SOCKET WELDED RECEIVE AND INSTALL ALL OWNER PROVIDED FITTINGS DESIGNED TO FIT PIPING FIXTURES. DIAMETERS. INSULATED IN RETURN AIR PLENUMS. 2. FIXTURES DESIGNATED FOR HANDICAP ACCESSIBILITY SHALL COMPLY WITH ANSI A 117.1, VENTING POLYVINYL CHLORIDE DRAIN, WASTE AND LATEST EDITION, INCLUDING ADOPTED INDIANA VENT PIPE (PVC): ASTM D2665, AMENDMENTS, INSULATED IN RETURN AIR PLENUMS. 3. PROVIDE BELLOWS TYPE WATER HAMMER ARRESTERS, STAINLESS STEEL CASHING AND BELLOWS, 250 PSI, INSTALL PER PDI STANDARD WH2O1. PIPING 1. ALL EXPOSED SUPPLY PIPES AND METAL TRIM IN CONNECTION WITH THE FIXTURES SHALL BE CHROME PLATED RED BRASS OR BRONZE, PROVIDE CHROME PLATED STOP VALVES IN ALL SUPPLIES TO ALL FIXTURES. CAULK ALL FIXTURES WITH WATERPROOF SILICONE CAULK, TRAPS SHALL HAVE CLEANOUT PLUGS. INSTALL ONE PIECE CHROME ESCUTCHEON PLATE WITH SET SCREW AT WALL PENETRATIONS. 2. WASTE AND VENT PIPING MAINS SHALL BE PITCHED AT 1/8" PER FOOT. LATERAL BRANCHES SHALL BE PITCHED 1/4" PER FOOT TOWARD THE SANITARY SEWER MAIN. THEY SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH THE CURRENT INDIANA PLUMBING CODE AND TESTED PER AUTHORITY HAVING JURISDICTION. 3 VERIFY LOCATION, DEPTH AND SIZE OF SANITARY SEWER CONNECTION POINTS. CONNECT AS REQUIRED. OUTSIDE SEWER SHALL BE INSTALLED WITH MINIMUM OF T-0" COVER. COORDINATE CONNECTIONS WITH SITE CONTRACTOR AND LOCAL UTILITY 4. ALL OUTSIDE WATER PIPING SHALL BE COVERED WITH A MINIMUM OF 52". 5. ALL PIPING INTERIOR PENETRATIONS OF WALLS AND FLOORS SHALL BE SLEEVED, SEALED AND FIRE RATED WHERE REQUIRED. ALL EXTERIOR UNDERGROUND PENETRATIONS OF BUILDING WALLS OR FOUNDATIONS INTO BASEMENTS OR PLUMBING INSULATION 1. ALL PIPING INSULATION MATERIALS SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS (ON THE FLAME SPREAD TEST SCALE) AND SMOKE DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST SCALE) OR AS DEFINED BY NFPA 255 STANDARD METHOD OF TESTING OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, LOCAL CODES ANQ LOCAL AUTHORITIES HAVING JURISDICTION. ALL PVC PIPING LOCATED IN RETURN AIR PLENUM SPACES OR EXPOSED SHALL BE INSULATED. 2. INSULATION: INSTALL ALL INSULATION IN STRICT ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS IN A TIGHT AND NEAT MANOR. NO SAGGING, FRAYED OR TORN INSULATION WILL BE EXCEPTED. UNLESS OTHERWISE NOTED ON PLANS PIPING SHALL BE INSULATED AS FOLLOWS: HW FLEXIBLE UNICELLULAR PIPE INSULATION, ASTM C534, TYPE 1. MINIMUM THICKNESS ;HALL BE 1/2" FOR PIPE SIZES 1-1/4" AND LESS AND SHALL BE 1" FOR 1-1/2" AND C3REATER. CHECK TEST AND START UP REQUIREMENTS 1. CLOSE OUT: PROVIDE MANUFACTURERS OPERATION AND MAINTENANCE MANUALS AND AS BUILT DRAWINGS. PROVIDE (1) TRAINING SESSION TO OWNER SELECTED PERSONNEL AS REQUESTED. 2 FILL SYSTEMS WITH FRESH WATER AND INSPECT ALL CONNECTIONS FOR LEAKAGE. FIRE ALL WATER HEATERS AND START ALL PUMPS. CORRECT ALL LEAKS AND VIBRATIONS AS REQUIRED. hitura ARCHITECTURE PLANNING DESIGN CREATION 55 MONUMENT CIRCLE SUITE 1212 INDIANAPOLIS, INDIANA 46204 - 2910 PH 317-348-1000 FAX 317-951-1213 WWW.AR C H ITU RAC O R P. C O M GOODERUM & ASSOCIATES ENGINEERING MEP Engineer 874 Cheltenham Way p Avon, IN 46123 P: 317.506.8151 F. 317.745.5761 E: gnaengineering@aol.com THIS DRAWING AND ALL INFORMATION ON IT IS THE PROPERTY OF ARCHITURA CORPORATION. IT IS CONFIDENTIAL AND ITS SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR OTHER PURPOSES IN CONNECTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT OR OTHER RESERVED RIGHTS. THIS DRAWING NOR ANY PART OF IT NOR ANY INFORMATION CONCERNING IT MAY BE COPIED, EXHIBITED, REPRODUCED OR FURNISHED TO OTHERS NOR MAY PHOTOGRAPHS BE MADE OF ANY ARTICLE FABRICATED OR ASSEMBLED FROM THIS DRAWING WITHOUT WRITTEN CONSENT OF ARCHITURA CORPORATION. O COPYRIGHT 2014 ARCHITURA CORPORATION SIGNATURE SEAL 09-12-2017 °,°°���y'sTE'�'DF•pG, = =`10200395; lz Q STATE OF 7�6 "ON/till 111111m \\ DATE: 09/12/17 COMMISSION: 17100 DRAWING BY: CHECKED BY: REVISIONS MICHIGAN ROAD SELF STORAGE MICHIGAN ROAD CARMEL, IN 46032 SHEET TITLE PLUMBING SYMBOLS, ABBREVIATIONS AND SPECIFICATIONS. SHEET NUMBER Pool