HomeMy WebLinkAbout17080193.28IBR DUPLEX BUILDING BLDG 1 FOUNDATION 46 PLAN 1-2. 6 5 4 IBR DUPLEX TYPE 'A' BUILDING BLDG 2 FOUNDATION @T,; -)_PLAN 1/8"-1'-O' , 3 2 GENERAL NOTES: 1. COORDINATE POURING O" GARAGE FLOOR WITH DETAIL 5D/S501 AND ELEVATION OF DRIVEWAY SLAB. NOTE SLOPE IN GARAGE FLOOR, 2. SEE PLUMBING PLANS FOR FIX'URE LEGEND AND LOCATIONS. 3. SEE PLUMBING PLANS FOR LOCAPONS OF ALL UNDER SLAB ELEMENTS. GENERAL FOUNDATION NOTES: 1. OUTSIDE FACE OF STUD EOUALS OUTSIDE FACE OF TURN -DOWN SLAB AT TYPICAL SECTION. 2. 5$" IS THE DIMENSION FROM OUTSIDE FACE OF STUD AND TURN -DOWN SLAB TO THE OUTSIDE FACE OF GRACE BEAM. SEE FOUNDATON DETAILS. 3. A_L REINFORCEMENT - MINIMUM 3" COVERAGE. GRADE REAM, 3000 PSI (ASTM C94, LATEST EDITION) CONCRETE c_LAR, 4000 PSI (ASTM C94. LATEST EDITION) �CTERIOR CONCRET�SI A� 4000 PSI (ASTM C94. LATEST EDITION) AIR-ENTRANED CURE ALL EXPOSED CONCRETE PER IBC 1905.11 4. ALL BRICK TIES ARE TO BE ANCHORED THROUGH SHEATHING AND FASTENED TO THE WOOD STUDS, NOT SHEATHING ONLY 16" O.C. VERTICALLY AND HORIZONTALLY. 5. ALL REINFORCING BARS AT BOTTOM OF GRADE BEAMS ARE TO BE SUPPORTED ON CHAIRS OR CONCRETE MASONRY BRICKS. 6. REINFORCE CONCRE-E SLAB WITH 6x6-W1.4xW1.4 W.W.F. FOR CRACK CONTROL. SLAB CAN BE REINFORCED WITH FIBERMESH FIBERS AS AN ALTERNATE. 7. ALL PRESSURE -TREATED LUMBER MUST BE ARSENIC -FREE 8. SEAL RUBBERIZED ASPHALT LAMINATED MEMBRANE TIGHT AT ALL CORNERS. 9. CURING COMPOUND: CLEAR 10. INSTALL SAW CUT JOINTS (SEE 2E/S511) SAME DAY SUB S POURED. 11. NOT USED 12. SEE PLUMBING SHEETS FOR LOCATION OF FLOOR DRAINS, OPEN SITE DRAINS AND ALL FLOOR DRAINS. SET DRAINS PRIOR TO POURING SLAB. 13. ALL OPEN SITE DRAINS RE TO RISE IN STUD WALLS. 14. PROVIDE Yx" MAX ELEVATION CHANGE BETWEEN ALL PORCHES AND SIDEWALKS. 15. ALL REINFORCING BAR IN CONCRETE FOOTINGS IS TO BE ELECTRICALLY GROUNDED (REAR CENTER OF BUILDING). 16. REFERENCE TITLE SHEET FOR MINIMUM SOIL LOADS. SPECIFIC NOTES: SOI, 4' CONCRETE SLAB-ON-GRA3E REINFORCED WTH 6x6-W1.4xW1.4 W.W.F. OVER 6 MIL VAPOR BARRIER WITH 12' LAP OVER 4" OF COARSE #5 AGGREGATE PER RADON SYSTEM NOTE 2 (SEE RADON SYSTEM NOTES). S02. 12'W x 160" TURNED -DOWN SLAB TO 12" BELOW GRADE MIN.; TYPICAL EACH PATIO. SEE DETAIL 4C/S511 SO3. 12'6 x2'-6" DEEP ROUND CONCRETE PIER AT EACH POST • TYPICAL (2) EACH PORCH OF DWELLING UNITS. SEE DETAIL 4C/S511 SO4. SAW CUT CONTROL JOINT - HAND TOOL PORCH AND PATIO CONTROL JOINTS S05. OPEN SITE DRAIN (O.S.D.) S05. FLOOR DRAIN SOT 4" RADON PVC VENT PIPE AND SUCTION PR (4'-0'x4'-O"x8" DEEP MIN.) SEE DETAILS AND NOTES. S08. PROVIDE (2) 84 RE -BAR, 4' LONG FOR CONTROL JOINT RE-ENTRANT CONTROL S09: 24"0 x2'-6" DEEP ROUND CONCRETE PIER AT EACH POST, TYPICAL (4) EACH PORCH OF OLV BUILDING. SEE DETAIL 4C/S511. SID: RECESS AREA 1'" FOR SHOWER (SEE MANUFACTJRER'S INSTALLATION INSTRUCTIONS h TO CONFIRM SIZE) RADON SYSTEM NOTES 1. USE THE FOLLOWING NOTES FOR THE INS7ALLATION OF A SOIL DEPRESSURIZATION SYSTEM AS RECOMMENDED BY THE EPA. WITH ROUGH -IN FOR THE FUTURE INSTALLATION OF A FAN FOR AN ACTIVE SYSTEM. 2. GAS PERMEABLE LAYER TO CONSIST OF A MINIMUM 4" OF CLEAN COARSE AGGREGATE. /5, kJ" -1" DIAMETER WITH LESS THAN 10% PASSING THROUGH A Ji" SIEVE PER ASTM C-33-90. OR WASHED /8. 3. DOUR ALL SLABS TIGHT TO WALLS AND PENETRATIONS TO PREVENT AIR LEAKAGE. 4. PROPERLY SEAL ALL SLAB PENETRATIONS AND ALL JOINTS AND CRACKS W7H POLYURETHANE CAULK AND BACKER RODS OR APPROVED SEALANTS WHERE NEEDED AS REQUIRED TO PREVENT AIR LEAKAGE. 5. PVC RADON VENT TO BE LOCATED IN JTILITY ROOM WALL OF TWO BEDROOM UNIT, SEE PLUMBING PLANS FOR LOCATIONS. 6. VERTICAL PVC RADON VENT PIPE TO EXTEND FROM i" BELOW SLAB TO 12" ABOVE ROOF DECK. 7. CLEARLY LABEL VERTICAL RADON PIPE AT SLAB PENETRATION, 5'-0" ABOVE FINISH FLOOR, IN ATTIC SPACE AND AT ROOF PENETRATION. 8. PROPERLY SEAL AND BOOT ALL ROOF PENETRATIONS TO MAINTAIN ACCURATE FIRE RATINGS. 9. SEE SHEET 5531 FOR RADON DE -AILS AND SECTION. 1 the. U U :. studio... W � COPYRIGHT g OWNERSHIP OF 00^JMENTS tP-.1uwiea�a a Ian ea �v 9^AARR[ � sEu a�y�o 3TFCI� `,JlZ AF100033004 DATE: 07.10.2016 PROJECT NO.: 16002 CAD REFERENCE NO. ACA 2016 PLOT REFERENCE No. SEE LOWER LEFT DRAWING SCALE SEE DRAWING W[rsws 04.21.17 RENEW gT 05.05.17 81D SET UH N E01 MDMIleP Coun•y F°a Nrgnt�--,x>C ppv±;pPm.n• QCT T�- LU U w f -:Q azU)z _jLL] =o QLn Z W LL LLj W Qo OCA. 2 a Tr 1 B DUPLEX Q FOUNDATION PLAN