HomeMy WebLinkAbout17080193.334" CONIC. SLAB w/7% AIR ENTRAINMENT, REINF. WRH 6x6-W7.4x12.4 WWF OVER WASHED #58 FILL m 0.-0. :0.NT'NU.USNOSE BAR, -2. #5 RE -BAR 4- -1 12; 4'-C- O.C. --- (4) #5 BARS CONT. (2 TOP, 2 BOTTOM) (3" CONIC. COVER) GROUNDING WIRE ATTACHED TO REBAR AS REQUIRED GARAGE BOOR OVERHEAD GARAGE WOR J' 17=Y ° • l:l GARAGE THRESHOLD 5C DETAIL PUN) TURNED -DOWN SLAB -ON - GRADE v� o SLOPE 1:96 MIN. TODLED EDGE, �11-R (1) #5 RE -BAR, TOP AND BOTTOM, CONTINUOUS 4" OBMCI Sl)IB JZ AIR 2x4 TREATED PLATE W/ EMIWIIpMENT, RENF. WITH SILL SEALER W/ i"I.4 xWIA WAY GAR SIMPSON _ p9E,p #56 TILL TITEN HD 4'X8" ANCHOR -RESHOLD IN FULL BED SCREW (THD 50800H) OF SEALANT (BOTH SLABS F_JSH AT ADA) 4" CONC. SLAB W/7% AIR 24_ ENTRAINMENT, REINF. WITH #5 BARS AT _ 6x6-W1.4x12.4 WWF OVER 16' O.C. =r WASHED #58 FILL SLOPE )8"/FT. MIN. 0'-O" (4) #5 BARS CONT. 4" OBMCI Sl)IB JZ AIR 6 MIL VAPOR BARRIER - EMIWIIpMENT, RENF. WITH 16 MIN 10" MIN i"I.4 xWIA WAY GAR #4 NOSE BAR, p9E,p #56 TILL CONTINUOUS RKAD INSULATION, EXTRUDED POLY- -24-1 #5 RE -BAR AT STYRENE, 2'X16", R10, MUST BE A MINIMUM 4'-0" O.C. 4'-0" FROM TOP OF SLOPE L'6 -/FT. MIN_ SLAB DOWN (COMBINATION OF VERTICAL AND HORIZONTAL) 4'-D" O.C. (4) #5 BARS CONT. 10" IW IBOTTOM) STYRENE, 2"X16-, RIO. (3- CONIC. COVER) - -CONCRETE GRADE BEAM GROUNDING WIRE ATTACHED TO REBAR 4'-0" FROM TOP OF AS REQUIRED -P `ATICN 6A DETAIL 5 pTR�N�EW7EWRF DOWN AT CDNCRETE SLAB EDGE. TURNED DOWN 1 •`\I CONIC. PIER (BEYOND AT I ■ �■ CORNERS) WITH (4) 14 I • • I RE -BAR VERT AND j13 1 ■ ■ TIES AT 12. O.C. (SEE PUN FOR SIZE) i ■ • I I ■ ■ I I ■ ■ I I ■ ■ I t2" WN SLAR EDGE AND PORCH COLUMN FOUNDATION 4C DETAIL11 8' 1:12 w� SILL SEALER W/ 16 MIN 10" MIN o0 wo GRADE m g YJ- EXPANSION STRIP ■ • #5 BARS AT 24- CONTINUOUS '_ 6. O.C. =' Ir !' SLOPE L'6 -/FT. MIN_ MINI4" CONC. SIAiJMIiI`7x AR ENTRAINMENT. RE1NF. WITH 6x6 -W1.4 xWI.4 W.W.F OVER WASHED 056 +LLL RIGID INSULATION, EXTRUDED POLY- STYRENE, 2"X16", RIO, MUST BE A MINIMUM 4'-0" FROM TOP OF SLAB DOWN (COMBINATION OF VERTICAL AND HORIZONTAL) NCETE GRADE BEAM PORCH FOUNDATION DETAIL 4A 18" 1:1■ 2 4 �i"4x16" LONG SMOOTH DOWEL CONSTRUCTION JOINT 0 24. O.C. COOT OR WRAP ONE END TO PREVENT BOND CONSTRUCTION JOINT DETAIL 3E1-_1• 1' 18- 1:1 2x4 TREATED PLATE W/ SILL SEALER W/ 16 MIN 10" MIN SIMPSON TITEN HD }"X8" ANCHOR GRADE m g SCREW (THD 50800H) ■ • m CONTINUOUS 04 4" CONC. SLAB w/7% AIR rnlroelnu.r.T CONTROL JOINT 2E DETAIL 1 12 �. 6x6-W1.4x12.4 WWF OVER \ WASHED #58 FILL 0'-0" 3, EXTRUDED POLY - STYRENE. 2"x8" 16 MIN 10" MIN ■� , GRADE . `--`-- /y� 6 MIL VAPOR BARRIER #4 NOSE BAR, ■ • ' CONTINUOUS ■ 24' ---1 #5 RE -BAR A7 ` RIGID INSULATION, 4'-D" O.C. `�. EXTRUDED POLY- ° ° STYRENE, 2"X16-, RIO. ° MUST BE A MINIMUM 4'-0" FROM TOP OF d S SLAB DOWN (COMBINATIONN ° _ _,g OF VERTICAL AND < • �. HORIZONTAL) (2 TOP, 2 BOTTOM) (3" CONIC. COVER) 16 MIN 10" MIN GROUNDING WIRE ATTACHED TO REBAR CONCRETE GRADE BEAM AS REQUIRED TYPICAL PERIMETER rCUNDATICN 2A DETAIL e 1:123 2 GENERAL NOTES: 1. COORDINATE POURING OF GARAGE FLOOR WT'H DETAIL 60/S501 AND ELEVATION OF DRIVEWAY SLAB. NOTE SLOPE IN GARAGE FLOOR. 2. SEE PLUMBING PLANS FOR FIXTURE LEGEND AND LOCATIONS. 3. SEE PLUMBING PUNS rOR LOCATIONS OF ALL ENDER SLAB ELEMENTS. GENERAL FOUNDATION NOTES: 1. OUTSIDE FACE OF STUD EOUALS OUTSIDE FACE OF TURN -DOWN SUB AT TYPICAL SECTION. 2. %_ IS THE DIMENSION FROM OUTSIDE FACE OF SND AND TURN -DOWN SLAB TO THE OUTSIDE FACE OF GRADE BEAM. SEE FOUNDATION DETAILS. 3. ALL RENFORCEMENT - MINIMUM 3" COVERAGE. GRADE BEAM 3000 PSI (ASTM C94, LATEST EDITION) CONCRETE SLAR 4000 PSI (ASTM C94, LATEST EDITION) EXTERIOR GONGRE� S AR� 4000 PSI (ASTM C94, LATEST EDITION) AR-ENTRANED CURE ALL EXPOSED CONCRETE PER IBC 1905.11 4. ALL BRICK TIES ARE TO BE ANCHORED THROUGH SHEA-RING AND FASTENED TO HE WOOD STUDS, NOT SHEATHING ON Y 16' O.C. VERTICALLY AND HORIZONTALLY. 5. ALL REINFORCING BARS AT BOTTOM OF GRADE BEAMS ARE TO BE SUPPORTED Of, CHAIRS OR CONCRETE MASONRY BRICKS. 6. REINFORCE CONCRETE SLAB WITH 6x6-W1.4xW1.4 W.W.F. FOR CRACK CONTROL. SLAB CAN BE REINFORCED WITH FIBERMESH FSERS AS AN ALTERNATE. 7. ALL PRESSURE -TREATED LUMBER MUST BE ARSENIC -FREE. 8. SEAL RUBBERIZED ASPHALT LAMINA -ED MEMBRANE TIGHT AT ALL CORNERS. 9. CURING COMPOUND: CLEAR 10. INSTALL SAW CUT JOINTS (SEE 2E/S51 1) SAME DAY SLAB IS POURED. 11. NOT USED 12. SEE PLUMBING SHEETS FOR LOCAT'ON OF FLOOR DRAINS, OPEN SITE DRAINS AND ALL FLOOR DRAINS. SE' DRAINS PRIOR TO POURING SLAB. 13. ALL OPEN SITE DRAINS RE TO RISE IN STUD WALLS. 14. PROVIDE Y4 MAX ELEVATION CHANGE BETWEEN ALL PORCHES AND SIDEWALKS. 15. ALL REINFORCING BAR IN CONCRE'E FOOTINGS IS TO BE ELECTRICALLY GROUNDED (REAR CENTER OF BUILDING). 16. REFERENCE TITLE SHEET FOR MINIMUM SOIL LOADS. SPECIFIC NOTES: S01. 4' CONCRETE SLAB -ON -GRADE REINFORCED WITH 6x6-W1.4xW1.4 W.W.F. OVER 6 MIL VAPOR BARRIER WITH 12" UP OVER 4. OF COARSE 05 AGGREGATE PER RADON SYSTEM NOTE 2 (SEE RADON SYSTEM NOTES). S02. 12'1W x 160" TJRNED-DOWN SLAB TO 12" BELOW GRADE MIN.; TYPICAL EACH PATIO. SEE DETAIL 4C/S511 SO3. 12-0 x2'-6" DEEP ROUND CONCRETE PIER AT EACH POST. TYPICAL (2) EACH PORCH OF DWELLING UNITS. SEE DETAIL 4C/S511 SO4. SAW CUT CONTROL JOINT - HAND TOOL PORCH AND PATIO CONTROL JOINTS SO5. OPEN SITE DRAIN(O.S.D.) S06. FLOOR DRAIN SO7. 4- RADON PVC VENT PPE AND SUCTION PIT (4' -0"x4' -0"x8' DEEP MIN.) SEE DETAILS AND NOTES. SOB. PROVIDE (2) #4 RE -BAR, 4' LONG FOR CONTROL JOINT RE-ENTRANT CONTROL. S09: 24'e x2'-6" DEEP ROUND CONCRETE PIER AT EACH POST, TYPICAL (4) EACH PORCH OF OLY BUILDING. SEE DETAIL 4C/S51 I. SID: RECESS AREA 134' FOR SHOWER (SEE MANUFACTURER'S INSTALLATION INSTRUCTIONS & TO CONFIRM SIZE) RADON SYSTEM NOTES USE THE FOLLOWING NOTES FOR THE INSTALLATION OF A SOIL DEPRESSURIZATION SYSTEM AS RECOMMENDED BY THE EPA. WITH ROUGH -4N FOR THE FUTURE INSTALLATION OF A FAN FOR AN ACTIVE SYSTEM. 2. GAS PERMEABLE LAYER TO CONSIST OF A MINIMUM 4" OF CLEAN COARSE AGGREGATE. #5, V'-1' DIAMETER WITH LESS THAN 10% PASSING THROUGH A )S" SIEVE PER ASTM C-33-90. OR WASHED #8. 3. POUR ALL SLABS TIGHT TO WALLS AND PENETRATIONS TO PREVENT AIR LEAKAGE. 4. PROPERLY SEAL ALL SLAB PENETRATIONS AND ALL JOINTS AND CRACKS WITH POLYURETHANE CAULK AND BACKER RODS OR APPROVED SEALANTS WHERE NEEDED AS REQUIRED TO PREVENT AIR LEAKAGE. 5. PVC RADON VENT TO BE LOCATED IN UTILfTY ROOM WALL OF TWO BEDROOM UNI', SEE PLUMBING PLANS FOR LOCATIONS. 6. VERTICAL PVC RADON VENT PIPE TO EXTEND FROM " BELOW SLAB TO 12" ABOVE ROOF DECK. 7. CLEARLY SEL VERTICAL RADON PIPE AT SLAB PENETRATION, 5'-0" ABOVE FINISH FLOOR, IN ATTIC SPACE AND AT ROOF PENETRATION. 8. PROPERLY SEAL AND BOOT ALL ROOF PENETRATIONS TO MAINTAIN ACCURATE FIRE RATINGS. 9, SEE SHEET 5531 FOR RADON DETAILS AND SECTION. 1 the. 0 64U studio... W COPYR.G,- Br 04NERS-10 OF DEOCCME�NTS so,A1w e e se.�L .rcxu.. t)AV1p /r�� Z �AR00033004 1 BFATE OP DATE 03.10.2016 PROJECT NO.: 16002 CAD REFERENCE N0. ACA 2016 PLOT REFERENCE NO. SEE LOWER LEFT DRAWING SCALE SEE DRAWING axs�rs 04.21.17 RENEW SET 05.05.17 80 SET U ffHA N D HOMO- C-ty Are* N■I■hbml 0 DeveloG+I+eni NtO.Et* Int¢ LLI / Z (')z Jw=o CL 0 Ln Z LU 0. j LjJ G :EQ � O < � U 2 WIT MM FOUNDATION DETAILS Q - DUPLEX 5511