HomeMy WebLinkAbout17080193.446 5 4
3
5/s" TYPE 'X' GYPSUM
BOARD
DOUBLE 2x6 TOP
PLATE
GYPSUM BOARD ELAN
TYPE "X' ON RESIUANT
CHANNEL, 25 GA, 7/a" ne
INSULATION, (R13),
FIBERGLASS BATT,
KRAFT FACED
WALL BASE
.-t.
2x4 TOP PLATE TIGHT
TO DECK
ROOF TRUSSES
AT 24' O.C.
SLOPED WALL WITH 2x4
STUDS AT 24' O.C. AND
5/8' TYPE Y GYPSUM
BOARD ON EACH SIDE.
LEVEL 2 FINISH PER
ASTM C840.
RECYCLED ATTIC
INSULATION, R-49
2x NAILER EACH SIDE
STUDS, 2x4,
�- STAGGERED, 24' O.C.
pCi
n `a
00 O �
K Q
N
GYPSUM BOARD
TYPE 'X" ON RESILIANT
CHANNEL, 25 GA, 7/a"
BOTTOM PLATE, 2x6,
TREATED, WITH
EXPANSION ANCHORS
AT 4'-0" O.C. BY
FRAMING CONTRACTOR
100'-0"
TOP 9F SLAB
CONTROL JOINT, SAW
CUT SEE PLAN)
D I N NIT S P ReTION W ORCTION R317.1)
CEILING TO ROOF: COMPLY WITH U.L ASSEMBLY U314
STC REQUIRED: 45 PER IRC APPENDIX K AND ASTM E90
PARTY WALL
SECTION
2A 3/4^_
1:16
GENERAL NOTES:
1. SEE SHEET 5511 FOR FOUNDATION DETAILS.
2. FOUNDATION PLATES OR SILLS SHALL BE ANCHCRED INTO DONCRETE AND
SPACED NOT MORE THAN 6'-0" APART, THERE SH4LL BE A MINIMUM OF
TWO BOLTS PER PIECE, WTH ONE BOLT LOCATED NOT WORE THAN 12'
OR LESS THAN 4' FROM EACH END OF EACH PIECE. IBC 2308.6
3. EXTERIOR WAIL FRAMING TO USE LADDER BLOCKING AT CONNECTION WITH
INTERIOR WALLS AND CALIFORNIA OR 2 -STUD CORNERS AT EXTERIOR W
PERIMETER CORNERS.
4. WINDOWS IN FULL BRICK WALLS MUST BE SHIMMED, OUT )L" TO
ACCOMMODATE 'NCREASED BRICK LEDGE.
5. RETURN BRICK TO WALL AT DOOR LOCATIONS.
6. DOOR SILLS MUST BE FLASHED - GALVANIZED BEN- FLASHING AND
SILICONE CORNERS.
7. WINDOWS MUST BE 'LASHED - RUBBERIZED WINDOW TAPE, 12* LONGER
THAN WINDOW ROUGH OPENING. MINIMUM 6' WCE FOR 2.4 WALLS AND
8' WIDE FOR 2.6 WALLS.
ENERGY STAR NOTES:
1. SEE SHEETS A611 AND A612 FOR ENERGY STAR
EQUIPMENT.
2. USE 'ENERGY STAR QUALIFIED HOMES THERMAL
BYPASS CHECKLIST' (ESQHTBC) AS A GUIDE FOR
ITEMS NEEDING ATTENTION.
3. FILL ALL GAPS IN EXTERIOR WALL AND PARTY WALL
FRAMING, TOP AND SILL PLATES, SAW CUTS AND
FLOOR CRACKS WITH BACKER RODS AND
POLYURETHANE CAULK OR APPROVED SEALANTS
WHERE NEEDED AS REQUIRED TO PREVENT AIR
LEAKAGE.
4. ALL SLAB, WALL AND CEILING PENETRATIONS ARE TO
BE SIZED ACCORDINGLY AND GAPS ARE TO BE
SEALED BY RESPONSIBLE TRADE.
5. USE TREATED SOLID CARDBOARD BAFFLES AT ALL
EAVES TO PREVENT WIND WASHING AT ATTIC
INSULATION.
6. GLUE GYPSUM BOARD -0 TOP AND BOTTOM PLATES
BEFORE SETTING WITH SCREWS,
7. PROVIDE BATT INSULATION WITH KRAFT FACING
STAPLED TO FACE OF STUDS AND INSTAL;FD TO
GRADE I STANDARDS WITH NO GAPS, VOIDS, OR
COMPRESSIONS. INSET STAPLED FLANGES WILL NOT
BE EXCEPTED.
8. DO NOT COMPRESS WALL INSULATION. SPLIT AND
INSTALL INSULATION AROUND PIPES AND ELECTRICAL
WIRING.
9. PROVIDE EXPANDING FOAM INSULATION BEHIND
ELECTRICAL OJTLETS, SWITCHES AND PANELS
LOCATED ON EXTERIOR WALLS.
10. 00 NOT COMPRESS ROCF INSULATION AFTER
INSTALLATION; ADDITIONAL INSULATION IS REQUIRED
IF R -VALUE DECREASES BEFORE END OF
CONSTRUCTION.
ID•YxeM rte. gNWc
9"o -VA 0 bP PMM
cau
axM.— .0
pYMbmlMd bPAM
soft.soft.P"Nstl w
i owew to aAMa
b —pmt— lows
.. Fim Pw do we —Aki cr
9x*ea0 b bP Pkm
_ Drfa M cmAwd, Oad w
gWweao a bom. qAM
�-� BMMIWn I1LiLM br+raW a
90*90d a SAO-
- SMeMar q *0, CbAxoO Or gP¢xo od
W — ps.#- dears
I __ -_ RYW pYklln dam Coi/ootl
a 9MA4a! a ei OMa
—lta qMp MMMIMOawrWgWor
NMa: ohm"eIW10aIWrMo1M omb
,W MbW /MIIII "am
1
707
the. U
U
studio...
U
ct
F x�!IC wA
COPYRIGHT ! OWNERSHIP OF DOCUMENTS
•omnu�pm, c u
rw
L % A
� Aip0093004 s
� eaicar
DATE: 03.10.2016
PROJECT NO.: 16002
CAD REFERENCE NO. AGA 2016
PLOT REFERENCE NO. SEE LOWER LEFT
DRAWING SCALE SEE DRAWING
aWsaa
114.21.17 REVIEW SET
05.05.17 EMD SET
D H tD
MGn+�liOp CapNy Arep NeipfibmMad OevelcpmrN
072
ma[[cr ,rnc
LLI
U
Q Z u) Q
�Wzo
QLo Z
LU {..L LLj LL1
QO
OO
2
Slw
WALL SECTIONS —
DUPLEX
A313