HomeMy WebLinkAbout17080193.63BON OV CLOSET NECESSNFY FOR DUCTS TO FIT LAYOUT AS I SUPPLY TRUSS I I I I I I I \ I L SUPPLY \ •. �� SEALANT WITH SACKER R00 ELECTRICAL Y/A�I2 MFR. MODEL % DICT COOLING CAPACITY -----j - EER SHELF LII DRYER VENT, STANDARDS (LATEST EDMONS) TO ENSURE A COMPLETE PRE -FABRICATED. -�- 3. PROVIDE A COMPLETE AND WORKING SYSTEM EVEN THOUGH EACH AND EVERY ITEM MAY NOT BE SHOWN. i RIGID ALUMINUM METAL, 4"0, Y/f/F2 1L111NGNOTES i I I I I I OR CALVANfa© INSULATED, WrtH S'EEL oucC SMOOTH INTERIOR OUTDOOR HEAT BRYN(T t l I i (NO PLASTIC FLEX - WITH 24000230/1/60 6. FOR RETURN AIR, UNDERCUT BEDROOM. BATHROOM, AND swAnxe BACK JUG) BACK040 DAMPER, MASTER BEDROOM CLOSET DOORS 1J(2" FROM CONCRETE HALL CLOSET FURNACEi I WITH No SCREEN F2 NDOOR BRYANi II I I THRII-WNL , I l RETLRN AIR 1 'N f -• SOFFIT, AND ROOF CAPS. PROVIDE BACK-DRA=1 DAMPERS. pAV(p I FILTER) I 1 SEALANT WITH EXHAUST FAN. � (NO i ,I I' BACKER ROD BRICK SP AND WITH BACK -DRAFT DAMPERS. Ca I I I I, VENEER � ✓f� \ Y FURNACE BOx OUT C DETAIL ISE 3•_�4 6- 1:4 PENETRATION DETAIL: SEC`ON A -A SYSTEM NO. W -L-1062 F RATING - 1 HR. T RATING - 0 HR. L RATING AT AMBIENT - LESS THAN 1 CFM/SQ. FT. RATING AT 400 F - LESS THAN i CFM/SQ. FT. 1. WALL ASSEMBLY - THE FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDNIDUAL 0300 OR U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM. 2x4 IN. LUMBER SPACED 16 IN. O.C. STEEL STUDS T BE MIN. 3% IN. WIDE AND SPACED MAX. 24 IN. O.C. B. WALL BOARD, GYPSUM' - ONE LAYER OF NOM % IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAMETER OF OPENING IS 4V, IN. 2. THROUGH -PENETRANTS - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED WITHIN THE FIRESTOP SYSTEM. THE SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE A MON. Y. IN. TO A MAX. % IN. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. STEEL PIPE - NOM. 4 IN. DIAMETER (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE. B. IRON PIPE - NOM. 4 IN. DIAMETER (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT - NOM. 4 IN. DIAMETER (OR SMALLER) ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. D. COPPER TUBING - NOM. 4 IN. DIAMETER (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. E. COPPER PIPE - NOM. 4 IN. DIAMETER (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. 3. FILL, VOID OR CAVITY MATERIALS- - CAULK - MIN. Jf IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. GENERAL ELECTRIC CO. SILICONE PRODUCTS DN. - PENSIL 100 CAULK. SPECIFIED TECHNOLOGIES INC. - PENSIL 100 SEALANT AND PENSIL 3DO SEALANT. -BEARING THE UL CLASSIFICATION MARKING DISCHARGE P_ENJM DRYER VENT U5E DETAIL 6' 774- INSULATED FLEX SUPPLY DUCT IN TRUSS SPACE 'III +6'-116• 'BUSS 9FAANC COOLNG Cog i flRM IC 14'x24'.24' LINED PLENUM ROOF CAP (SIMILAR TO NUTONE #841' WITH BIRD SCREEN; MATCH COLOR OF ROOF. SET ROOF CAP IN ROOFING MASTIC HOLE CUT FOR DUCT (MINIMUM SIZE) 24'x24- RETURN NR GRILLE LOCATED IN HALL WALL (ND WALL FILTER) FLOOR UNE FURNACE RETURN AIR 5C DES ALTERNATE DUCT PATH HORIZONTAL TO SIDE WALL: USE SAME DETAIL AS DRYER VENT BUT INCLUDE BUGSCREEN--------,-- CEILING BOARD SET SHINGLES IN MASTIC OVER UPHILL FLANGE OF ROOF CAP SEAL AROUND DUCT PENETRATION WITH ROOFING MASTIC PRIOR TO SHINGLE AND ROOF CAP INSTALL (ONE FAN VENT PER ROOF CAP). 4"0 INSULATED SOLID METAL 4 x 3 SHEET METAL DUCT INCREASER. INSULATION i CLG. MOUNTED FAN 110 CFM WITH BACKDRAFT DAMPER. MOUNT WITHIN ONE FOOT OF SHOWER EXI-AUS' FAN 56 DETAIL 1' 6. HVAC EQUIPMENT SCHEDULE the. 0 2. THE PROPOSED HVAC SYSTEM j5._ELECTRIC HEAT PUMP UPFLOW FURNACE_ WITH A/C DESIGNED AND SIZED TQ WRIC ELECTRICAL Y/A�I2 MFR. MODEL % NOMINAL COOLING CAPACITY 2. COORDINATE ALL MECHANICAL WORK WITH ALL OTHER BUILDING EIEC. EER ARI RETERENCE WITH ALL LOCAL, STATE AND FEDERAL CODES AND w STANDARDS (LATEST EDMONS) TO ENSURE A COMPLETE TON 3. PROVIDE A COMPLETE AND WORKING SYSTEM EVEN THOUGH EACH AND EVERY ITEM MAY NOT BE SHOWN. "15-25 4. ALL DRYER VENTS MUST MEET LOCAL, STATE AND Y/f/F2 1L111NGNOTES HP2 OUTDOOR HEAT BRYN(T 215BNA024000PUMP HEAT PUMP 2 24000230/1/60 6. FOR RETURN AIR, UNDERCUT BEDROOM. BATHROOM, AND swAnxe t MASTER BEDROOM CLOSET DOORS 1J(2" FROM CONCRETE 12.5 7029703 1 F2 NDOOR BRYANi FX4DNFO25LOOFAN 2 gti SOFFIT, AND ROOF CAPS. PROVIDE BACK-DRA=1 DAMPERS. pAV(p 8. USE 4.0 INSULATED METAL DUCT FOR BATHROOM 0�y EXHAUST FAN. � 9. PROVIDE EXHAUST FANS RATED FOR 110 CFM AT 1125 FAN COIL SP AND WITH BACK -DRAFT DAMPERS. Ca 10. MAIN SUPPLY TRUNK IS LOCATED IN ATTIC TRUSS SPACE. 24000 8.7 230/1/60 7029703 12.3 ALTERNATE STANDARD GAS FORCED AIR SYSTEM 11. PROVIDE FURNACES MANUFACTURED BY BRYANT USING A NOTES: PURON REFRIGERANT OR APPROVED EQUAL. PROJECT k0.: I6W2 1. ENERGY STAR CAD REFERENCE 40. ACA 2016 2. SUPPLEMENTAL HEAT 150, BRYART KFCEH310IC15 13. INSTALL ROOF VENTS ONLY ON REAR PORTION OF ROOF DRAWING SCALE SEE DRAWING 3. PROADE HONEYWELL FOCUS PRO 5000 DIGITAL THERMOSTAT OR SIMILAR. SN9p.$ 14. INSTALL THERMOSTATS NO HIGHER THAN 48' A.F.F. 1-7 r 6" INSULATED FLEX SUPPLY DUCT 6 5 4 3 CONDENSING' UNIT 6' INSULATED FLEX SUPPLY DUCT ,`,,,,������a�u�mnnun♦ 'IL �O♦♦`,`♦♦♦♦♦RETTURN AIR �RILLE TM 6" INSULATED FLEX SUPPLY O THROUGH ROOF IN UNITS ON PARKING LOT SIDE V Fi 4' INSULATED' FLEX SUPPLY. DUCT 6" INSULATED FLEX SUPPLY DUCT MECHANICAL 1 BEDROOM - TYPE A g6_ - PLAN A L 2 GENERAL NOTES: 1. COMPLY WITH INDIANA MECHANICAL CODE. the. 0 2. THE PROPOSED HVAC SYSTEM j5._ELECTRIC HEAT PUMP UPFLOW FURNACE_ WITH A/C DESIGNED AND SIZED TQ MEE_ ACCA J FOR DW IIIN9 UNITS AND MANUAI, (� N FOR OFFICE BUI SINU THF F"RE HVAC SYSTEM ja R 0 IR D TO HF ENLS2L 57AR RATED 2. COORDINATE ALL MECHANICAL WORK WITH ALL OTHER BUILDING U =studio... studio"' U TRADES. INSTALL ALL WORK IN ACCORDANCE 11.0 WITH ALL LOCAL, STATE AND FEDERAL CODES AND w STANDARDS (LATEST EDMONS) TO ENSURE A COMPLETE AND OPERABLE SYSTEM. 3. PROVIDE A COMPLETE AND WORKING SYSTEM EVEN THOUGH EACH AND EVERY ITEM MAY NOT BE SHOWN. COPYRIGHT R OWNERSHIP OF DOCUMENTS M c 4. ALL DRYER VENTS MUST MEET LOCAL, STATE AND FEDERAL CODE REQUIREMENTS. (SEE DETAIL). NEATLY CUT ALL OPENINGS. 5. PROVIDE WASHER/DRYER HOOK-UPS TO ALL UNITS. FACING WASHER AND DRYER, WASHER ALWAYS ON LEFT. 6. FOR RETURN AIR, UNDERCUT BEDROOM. BATHROOM, AND swAnxe t MASTER BEDROOM CLOSET DOORS 1J(2" FROM CONCRETE FLOOR. 7. PROVIDE INSECT -PROOF AND WEATHER-PROOF WA -L, gti SOFFIT, AND ROOF CAPS. PROVIDE BACK-DRA=1 DAMPERS. pAV(p 8. USE 4.0 INSULATED METAL DUCT FOR BATHROOM 0�y EXHAUST FAN. � 9. PROVIDE EXHAUST FANS RATED FOR 110 CFM AT 1125 A: 1 SP AND WITH BACK -DRAFT DAMPERS. WGOEOi 1 10. MAIN SUPPLY TRUNK IS LOCATED IN ATTIC TRUSS SPACE. AIR DELIVERY IS THROUGH CEIUNG REGISTERS. RETURN -AIR IS THROUGH A SINGLE DUCTED CENTRAL GRILLE LOCATED IN WALL ADJACENT TO FURNACE LOCATED IN UTILITY ROOM. 11. PROVIDE FURNACES MANUFACTURED BY BRYANT USING A DATE 03.10.2046 PURON REFRIGERANT OR APPROVED EQUAL. PROJECT k0.: I6W2 12. SEE STRUCTURAL FOR BORING AND NOTCHING NOTES. CAD REFERENCE 40. ACA 2016 PLOT REFERENCE N0. SEE _OWER LEFT 13. INSTALL ROOF VENTS ONLY ON REAR PORTION OF ROOF DRAWING SCALE SEE DRAWING OF BUILDING. SN9p.$ 14. INSTALL THERMOSTATS NO HIGHER THAN 48' A.F.F. SET15. NEATLY BUNDLE AND SECURE ALL LOW VOLTAGE WIRES TO HVAC EQUIPMENT. 16. ALL DUCT JOINTS MUST BE SEALED WITH MASTIC F04-21.177 FOLLOWED BY TAPES THAT ARE LINED AND LABELED IN ACCORDANCE WITH UL 181A OR UL 1818. DUCT CONNECTIONS TO FLANGES OF AIR DISTRIBUTION SYSTEM EQUIPMENT SHALL BE SEALED AND MECHANICALLY FASTENED. CLOTH DUCT TAPE IS NOT PERMITTED ON THIS PROJECT. THIS INCLUDES ALL RETURN AIR DUCTS AND PENETRATIONS. TRADE IS RESPONSIBLE TO SEAL PENETRATIONS THROUGH ONE AND TWO HOUR WALLS AS 1- REQUIRED. 17. PROPERLY CAULK AND/OR FIRE STOP ALL MECHANICAL f U PENETRATIONS AND GAPS THROUGH WALLS AND CEILINGS. ,. 18. PROVIDE DRYER BOXES BEHIND DRYER; N.O. VATE TECHNOLOGIES, -DRYER BOX" MODEL #350 (FOR 2x4 WALLS) #425 (FOR 2x6 WALLS). "Poe., mu 19. CENTER DRYER BOXES ON DRYER CENTERLINE AND SET DIRECTLY ON 2x4 SOLE PLATE. 20. PROPERLY FIRE -STOP ALL PENETRATIONS THRU 1 -HOUR WALLS TO ENSURE 1 -HOUR ENVELOPE IS MAINTAINED. CONTRACTOR PENETRATING 1 -HOUR WALL IS RESPONSIBLE FOR WORK REQUIRED TO ENSURE RATING OF WALL IS MAINTAINED. SUBMIT LITERATURE DESCRIBING COLLARS, FIRE-RESISTANT CAULK, AND DETAILS FOR APPROVAL PRIOR TO WORK REQUIRED FOR PENETRATIONS THRU 1 -HOUR ENVELOPE. 21. DUCT INSULATION: 1 E j U 21.1. FOR METAL DUCT, PROVIDE 1J4' THICK 3'4 LB. DENSITY FIBERGLASS INSULATION WITH VAPOR BARRIER JACKET. 21.2. FOR FLEXIBLE DUCT, PROVIDE FLEXIBLE, r l CLASS 1 AIR DUCT CONSTRUCTED OF METAUZED POLYESTER FILM F­� Q LAMINATED ON SHEET WIRE REINFORCING WITH %- Q Z (n ZQ THICK, X LB. DENSITY FIBERGLASS INSULATION AND J FIRE RETARDANT REINFORCE VAPOR BARRIER 'STANDARD Uj 0 (HI -VINYL); COMPLY WITH NFPA BOA, FOR THE Lo Z INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS' AND UL STANDARD 181 Cc Q O - 'STANDARD FOR FACTORY -MADE AIR DUCTS AND AIRUj r- J CONNECTORS'; PROVIDE WIREMOLD TYPE WCK (,(J W FLEXIBLE DUCT OR EQUAL.C 21.3. DRYER VENT, RANGE HOOD VENT AND FRESH AIR c < 0 INTAKE DUCT LOCATED IN ATTIC MUST BE INSULATED.O (D r- Q v U SPECIFIC NOTES: 2 1. DRYER BOX & VENT, SEE GENERAL NOTES 14 & 15. SEE DETAIL 5E/M411. ALL DUCTWORK IN ATTIC MUST BE INSULATED. 2. CONDENSING UNIT TO BE PLACED ON 4" PEDESTALS - NOT DIRECTLY ON PATIO. 3. KITCHEN EXHAUST MUST BE DUCTED TO THE EXTERIOR; EXIT THROUGH WALL WHERE RANGE IS LOCATED ON EXTERIOR WALL 1 SEPT TIRE `IBR MECHANICAL Q PLAN SET - M41 1 .AlafnM411