Loading...
HomeMy WebLinkAbout17080193.64BOX OUT CLOSET NECESSARY FOR DUCTS TO FR LAYOUT nnI "1 1114 AS SUPPLY ' ,i TRUSS I� Inn`' I LI I I LLLL1444 I i i l SUPPLY �� "�� _ SEALANT WITH - HACKER ROD ELECTRICAL MFR. MODE_ ) DUCT ♦ I CO01_?NG CAPACIGY HEATING CAPACFY HSPF RATINGSEEREER i r------� I EC. SHELF\� 1 I DRYER VENT. V/A/HZ I i I I I PRE -FABRICATED, M q10� METAL. 4,•I, OR fiAL INSULATED. WITH TON (9TUH) (BIH) I I I ) I I I STEEL BRED SMOOTH INTERIOR FNISH, WITH Y/ R1TNG t 1 I i (NO PLWM FLEX BACK RAFT DAMPER, HP2 HALL CLOSET ; I FllN44CE I� I II II WITH NO SCREEN 2 24000 11 THR1-ILL 15.25 230/1/60 I I RETURN AR SEALANT VATH PUMP (NO FILTER) i i I I BACKER ROD - BRICK VENEER �I li a^ 6E DETAIL 5" O PENETRATION DETAIL: SECTION A -A SYSTEM NO. W -L-1062 F RATING - 1 HR. T RATING - 0 HR. L RATING AT AMBIENT - NESS THAN 1 CFM/S0. FT. L RATING AT 400 F - LESS THAN 1 CFM/S0. FT. 1. WALL ASSEMBLY - THE FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM. 2x4 IN. LUMBER SPACED 16 IN. O.C. STEEL STUDS T BE MIN. 336 IN. WIDE AND SPACED MAX. 24 IN. O.C. B. WALL BOARD, GYPSUM' - ONE LAYER OF NOM % IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAMETER OF OPENING IS 434 IN. 2. THROUGH -PENETRANTS - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE INSTALLED WITHIN THE FIRESTOP SYSTEM. THE SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE A MIN. Y. IN. TO A MAX. % IN. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. STEEL PIPE - NOM. 4 IN. DIAMETER (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE. B. IRON PIPE - NOM. 4 IN. DIAMETER (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. CONDUIT - NOM. 4 IN. DIAMETER (OR SMALLER) ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. D. COPPER TUBING - NOW. 4 IN. DIAMETER (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. E. COPPER PIPE - NOM. 4 IN. DIAMETER (GR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. 3. FILL, VOID OR CAVITY MATERIALS- - CAULK - MIN. )a IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL GENERAL ELECTRIC CO. SILICONE PRODUCTS DN. - PENSIL 100 CAULK. SPECIFIED TECHNOLOGIES INC. - PENSIL 100 SEALANT AND PENSIL 300 SEALANT. -BEARING THE UL CLASSIFICATION MARKING JISCHhR E PEN1M COOLING COIL 14".24'x24" ;IED PLENUM ROOF CAP (SIMILAR -0 NUTONE /841' W!TH BIRD SCREEN: MATCH COLOR OF ROOF. SET ROOF CAP IN ROOFING MASTIC HOLE CUT FOR DUCT (MINIMUM SIZE) ALTERNATE DUCT PATH HORIZONTAL TO SIDE WALL: USE SAME DETAIL AS DRYER VENT BUT INCLUDE BUGSCREEN CEILING BOARD DRYER 'DENT 5E DETAIL 1:4 INSULATED Flit( SUPPLY DUCT W iRJ55 SPACE -- TRLSS EEtRINc - 24'x24" RETLRN NR GRILLE LOCATED W HALL WALL (NO WALL FILTER) FLOOR UNE FURNACE RETURN AIR U5C DETAIL NTSi SET SHINGLES IN MASTIC OVER UPHILL FLANGE OF r ROOF CAP y SEAL AROUND DUCT PENETRATION WITH ROOFING MASTIC PRIOR TO SHINGLE AND ROOF CAP INSTALL. (ONE FAN VENT PER ROOF CAP). ,-4"0 INSULATED SOUD METAL 4 x 3 SHEET METAL DUCT INCREASER. INSULATION 71111 1 I CLG. MOUNTED FAN 110 CFM WITH BACKDRAFT DAMPER. MOUNT WITHIN ONE FOOT OF SHOWER EX4AUST FAN DETAIL 5B 1:12 6 5 4 HVAC EQUIPMENT SCHEDULE MARK ELECTRICAL MFR. MODE_ NOMINAL CO01_?NG CAPACIGY HEATING CAPACFY HSPF RATINGSEEREER EC. AR SCE ROTES V/A/HZ TON (9TUH) (BIH) (HEATING) RATING Y/ R1TNG HP2 OUTDOOR HEAT BRYANT 2156NA024MODD 2 24000 15.25 230/1/60 12.5 7029703 1 PUMP F2 FNDOORL BRYAN FX4DNFO25LODFM a 240DO 8.7 230/%/60 7029703 12.3 COIL ALTERNATE STANDARD GAS FORCED AIR SYSTEM NOTES: 1. ENERGY STM 2, SUPPLEMENTAL HEAT 150, BRYANT KFCEH3101C15 3. PRONDE HONEYWELL FOCUS PRO 50DO DIGITAL THERMOSTAT OR SOIAAR. 3 CONDENSING '`. UNIT °NSLIA-=J LET 5'JP�L° GENERAL 7GC- 2BR JNIT 2B PLAN 4 NOTES: 1. COMPLY WITH INDIANA MECHANICAL CODE. 2. ILLL-PROPOSED HVAC SYSTEM j5 -ELECTRIC HEAT PUMP UPFLOW FURNACE WTH g/c DESIGNED AND SIZED IQ (� MEET ACOA MANUAL J FOR DWEWNG UNITS AND MANUAL N FOR OFFICE BWLDING, THE ENTIRE HVAC SYSTEM IS REQUIRED TO BE ENERGY STAR RATED. r'I studio... 2. COORDINATE ALL MECHANICAL WORK WITH ALL OTHER V BUILDING TRADES. INSTALL ALL WORK IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL CODES AND W STANDARDS (LATEST EDITIONS) TO ENSURE A COMPLETE AND OPERABLE SYSTEM. 3. PROVIDE A COMPLETE AND WORKING SYSTEM EVEN COPYRiGw- & OxNERSdP OF DOCUMENTS THOUGH EACH AND EVERY ITEM MAY NOT BE SHOWN. - 4. ALL DRYER VENTS MUST MEET LOCAL, STATE AND _ FEDERAL CODE REQUIREMENTS. (SEE DETAIL). NEATLY r= TIM CUT ALL OPENINGS. .x 5. PROVIDE WASHER/DRYER HOOK-UPS TO ALL UNITS. FACING WASHER AND DRYER, WASHER ALWAYS ON LEFT. " sa. xc 6. FOR RETURN AIR, UNDERCUT BEDROOM, BATHROOM, AND MASTER BEDROOM CLOSET DOORS T)�" FROM CONCRETE - FLOOR. gx 7. PROVIDE INSECT -PROOF AND WEATHER-PROOF WALL, SOFFIT, AND ROOF CAPS. PROVIDE BACK -DRAFT '6AV16 DAMPERS. 8. USE 4"0 INSULATED METAL DUCT FOR BATHROOM EXHAUST FAN. 9. PROVIDE EXHAUST FANS RATED FOR 110 CFM AT. 1125 £ SP AND WITH BACK -DRAFT DAMPERS. A-4Nf�� 10. MAIN SUPPLY TRUNK IS LOCATED IN ATTIC TRUSS SPACE. AIR DELNERY IS THROUGH CEIUNG REGISTERS. RETURN -AIR IS THROUGH A SINGLE DUCTED CENTRAL GRILLE LOCATED IN WALL ADJACENT TO FURNACE LOCATED IN UTILITY ROOM. DATE: 03.10 .201 1. PROVIDE FURNACES MANUFACTURED BY BRYANT USING A PROJECT NO.: 1660 0022 PURON REFRIGERANT OR APPROVED EQUAL CAD REFERENCE NO. ACA 2016 12. SEE STRUCTURAL FOR BORING AND NOTCHING NOTES. PLOT REFERENCE NO. SEE LOWER LEFT 13. INSTALL ROOF VENTS ONLY ON REAR PORTION OF ROOF ORAWNG SCALE SEE DRAWING OF BUILDING. 14. INSTALL THERMOSTATS NO HIGHER THAN 48" A.F.F. 0421.17 IREMEW SET 05.05.17 IND SET 15. NEATLY BUNDLE AND SECURE ALL LOW VOLTAGE WIRES TO HVAC EQUIPMENT. 16. ALL DUCT JOINTS MUST BE SEALED WITH MASTIC FOLLOWED BY TAPES THAT ARE LINED AND LABELED IN ACCORDANCE WITH UL 1B1A OR UL 1818. DUCT CONNECTIONS TO FLANGES OF AIR DISTRIBUTION SYSTEM EQUIPMENT SHALL BE SEALED AND MECHANICALLY FASTENED. CLOTH DUCT TAPE IS NOT PERMITTED ON THIS PROJECT. THIS INCLUDES ALL RETURN AIR DUCTS AND PENETRATIONS. TRADE IS RESPONSIBLE TO SEAL PENETRATIONS THROUGH ONE AND TWO HOUR WALLS AS REQUIRED. ! 17. PROPERLY CAULK AND/OR FIRE STOP ALL MECHANICAL U . PENETRATIONS AND GAPS THROUGH WALLS AND CEILINGS. 18. PROVIDE DRYER BOXES BEHIND DRYER: N.O. VATE TECHNOLOGIES, "DRYER BOX" MODEL 8350 (FOR 2x4 WALLS) #425 (FOR 2x6 WALLS). 19. CENTER DRYER BOXES ON DRYER CENTERLINE AND SET DIRECTLY ON 2x4 SOLE PLATE. 20. PROPERLY FIRE -STOP ALL PENETRATIONS THRU t -HOUR WALLS TO ENSURE 1 -HOUR ENVELOPE IS MAINTAINED. CONTRACTOR PENETRATING 1 -HOUR WALL IS RESPONSIBLE FOR WORK REQUIRED TO ENSURE RATING OF WALL IS MAINTAINED. SUBMIT LITERATURE DESCRIBING COLLARS. FIRE-RESISTANT CAULK, AND DETAILS FOR APPROVAL PRIOR TO WORK REQUIRED FOR PENETRATIONS THRU 1 -HOUR ENVELOPE. 21. DUCT INSULATION: W 21.1. FOR METAL DUCT, PROVIDE 1)¢" THICK 34 LB. DENS'!-" FIBERGLASS INSULATION WITH VAPOR BARRIER JACKET. /1 21.2. FOR FLEXIBLE DUCT, PROVIDE FLEXIBLE. CLASS 1 AIR DUCT CONSTRUCTED OF METALIZED POLYESTER FILM < 7 � Z LAMINATED ON SHEET WIRE REINFORCING WITH IYi" L Q THICK, X LB. DENSITY FIBERGLASS INSULATION AND FIRE RETARDANT REINFORCE VAPOR BARRIER W T- 0 (HI -VINYL); COMPLY WITH NFPA 90A, "STANDARD FOR Q LLD Z THE INSTALLATION OF AIR-CONDITIONING AND CD VENTILATING SYSTEMS' AND UL STANDARD 181 CD 'STANDARD FOR FACTORY -MADE AUR DUCTS AND AIR LLI CONNECTORS'; PROVIDE WIREMOLD TYPE WCKFLEXIBLE DUT OR LLQ 21.3. DRYER VENTCRANGEEQOOD VENT AND FRESH AIR < CD INTAKE DUCT LOCATED IN ATTIC MUST BE INSULATED.O i I� Q v U SPECIFIC NOTES: _ 1. DRYER BOX & VENT, SEE GENERAL NOTES 14 & 15. SEE DETAIL 5E/M411. ALL DUCTWORK IN ATTIC MUST BE INSULATED. 2. CONDENSING UNIT TO BE PLACED ON 4" PEDESTALS - NOT DIRECTLY ON PATIO. 3. KITCHEN EXHAUST MUST BE DUCTED TO THE EXTERIOR; EXIT THROUGH WALL WHERE RANGE IS LOCATED ON EXTERIOR WALL. 1 96T TI11E 2BR MECHANICAL Q PLAN M421