17080193.66
FIRE SUPPRESSION LIFE -SAFETY LEGEND MARK DESCR!P- ON SMOKE IONIZATION AND CARBON MONOXIDE DETECTOR COMBO UNIT CIRCUIT ELECTRICAL POWER LEGEND MARK DESCRIPTION M-1 8 METER BASE 1� EDP DISTRIBUTION PANEL, ELECTRICAL, 54" A.F.F. © DISTRIBUTION PANEL, TELEPHONE AND DATA, 54" A-F.F. MJ MAIN DISCONNECT Qj JUNCTION BOX B RECEPTACLE, DUPLEX, 120V. 20A �GrC. RECEPTACLE, DUPLEX, 120V, 20A, GROUND FAULT CIRCUIT INTERUPT f1I1 WP W RECEPTACLE, DUPLEX 120V, 20A, WATERPROOF ENCLOSURE - ARLINGTON CAT/DHBIC, 800.233.4717 Ipd1T� RECEPTACLE, 240/120V. 30A. 10, 2 POLE CIRCUIT }`z -H" Y RECEPTACLE, SPECIAL PURPOSE, (SEE NOTES) "4-4 HEIGHT OF CENTER OF DEVICE DLIGHT. FLUORESCENT. CEILING SURFACE MOUNT, 48"X12" ®EF FAN, EXHAUST WITH LIGHT 4 PHOTOCELL ELECTRIC LIGHTING LEGEND MARK DESCRIP-ON $ SWITCH, 1 -WAY $3 SWITCH, 3 -WAY $T SWITCH, TIMER DELAY AIR KING AMERICA MODEL AKD 760, TIED TO FAN ONLY -A- LIGHT, 2 -BULB, ALL PURPOSE CEILING MOUNT Y "B- LIGHT, 3 -BULB, CEILING MOUNT B LIGHT. 2 -BULB, CEILING MOUNT n 3 -BULB WALL MOUNT LIGHT BAR "E- RECESSED CAN UGHT /0- H _ "G" LIGHT, EXTERIOR WALL MOUNT }`z -H" Y LIGHT, 2 -BULB, EXTERIOR CEILING MOUNT LIGHT. FLUORESCENT. CEILING SURFACE MOUNT, 48-X24' DLIGHT. FLUORESCENT. CEILING SURFACE MOUNT, 48"X12" p K" FAN FAN, PENDANT MOUNT WITH LIGHT KIT 4 PHOTOCELL (IF REQUIRED) COMMUNICATIONS - SIGNAL LEGEND MARK DESCRIPTION Q RECEPTACLE, TE-EPHONE CATV W RECEPTACLE, CABLE TV, CO -AXIAL 1 0 DB PUSHBUTTON SWITCH, DOOR BELL ` EMERGENCY HORN STROBE, WALL MOUNTED Q THERMOSTAT 0 EMERGENCY PULL CHAIN 00 6 5 H STROBE LIGHT FOR PULL AND HORN A VV' - O.S.B. VINYL SIDING 2":6" FRAME WRAPP�D WITH ALUMINUM ELECTRIC PANEL ELECTRIC11 PANEL TO RE 10 � PB USE IN -BOX LOCATED IN THE CENTER FOR BRICK SERVICE TO UNIT REIN OF BUILDING. CAULK TOP AND SIDES AFTER INSTALLATION, 00 M.L. Q 200 A (TYP.) 00 00 HOUSE A BIC DG. (IF REQUIRED) SCHED 80 CONCRETE ENCASED REBAR CENTRALLY LOCATED ON REAR OF BLOGS ELECTRICAL PANEL 4E PLAN DETAIL CloLheS Crete"Surfam-Mourned LUR►rraiI Sea" 410.8(DJrf) aid (2} I j StoweIr, .T�n. '- 6 in. 91P pe $Dam Minimum MIN- Space I I CNWrence fiorn SLoraw Spae: c410.WKreI) Totally er. med ;mmnoeaoent 1 R. I 410.6(0x2) FluoemItt fUritnaras 6In. I Rgm 410-9 WP/GFI USE IN -BOX FOR BRICK OUTSIDE ELECTRICAL BEDROOM - TYPE A 4A PLAN -5 4 f I �2"x8' GROUND ROO MEN IN NEC REQUIREMENTS IN CONDUIT ABONE GROUT GROUND TO BOTTOM ROM REBAR, ALL BUILDINGS ELECTRIC RISER 3E DIAGRAM TTS EMERGENCY CALL SYSTEM: SCOPE OF WORK �) THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE EMERGENCY CALL SYSTEM CONSISTING OF CONDUIT, WIRING AND EMERGENCY STATIONS TO - INCLUDING BUT NOT LIMITED TO - PULL STATIONS, LIGHT, AND HORN/STROBE FIXTURES. DESCRIPTION OF EMERGENCY CAII SYSTEM OPERATION OF ANY EMERGENCY CALL STATIONS SHALL LIGHT THE 'EMERGENCY' LIGHT OVER THE IANEI ENTRANCE OF THE APARTMENT AND SOUND A HORN/STROBE FIXTURE. ALL SIGNALS AND LIGHTS SHALL REMAIN IN OPERATION UNTIL THE SYSTEM HAS BEEN RETURNED TO NORMAL OPERATION. PRODUCTS: EMERGENCY PULL STATION: SIMILAR TO EDWARDS MODEL NO. 6537. THE PULL STATION IS A FLUSH MOUNTED PULL CORD TYPE; SATIN FINISHED ID STAINLESS STEEL; ENGRAVED AND BLACK FILLED OF 'PULL FOR HELP'; & 6'-0" CORD IN LENGTH TO BE CUT OFF WITHIN 6" OF FLOOR. HORN/STROBE: SIMILAR TO EDWARDS MODEL NO. 70078-N5; WHITE & FLUSH CEILING MOUNTED. 1 BR SENSORY REQUIREMENTS: SMOKE DETECTION SHALL INCLUDE AUDIBLE NOTIFICATION COMPLYING WITH NEPA 72-2002. VISIBLE NOTIFICATION APPLIANCES SHALL BE PROVIDED AS PART OF THE UNIT SMOKE DETECTION SYSTEM. VISIBLE NOTIFICATION APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72-2002, BE POWERED BY A COMMERCIAL LIGHT AND POWER SOURCE, BE PERMANENTLY CONNECTED TO THE WIRING OF THE PREMISES ELECTRIC SYSTEM AND BE PERMANENTLY INSTALLED. ALL VISIBLE NOTIFICATION APPLIANCES PROVIDED WITHIN THE UNIT FOR SMOKE DETECTION NOTIFICATION SHALL BE ACTIVATED UPON SMOKE DETECTION. ALL VISIBLE NOTIFICATION APPLIANCES PROVIDED WITHIN THE UNIT FOR BUILDING FIRE ALARM NOTIFICATION SHALL BE ACTIVATED UPON ACTIVATION OF THE BUILDING FIRE ALARM IN THE PORTION OF THE BUILDING CONTAINING THE UNIT. 3 G- - �I� 6 7 MD I -44" GFl MICROWAVE --_. (/ +60" A.F.F. I ` (1.7.rN 5 1 _ 'I 9 .GFI r. 1 .I GFl 12 _GFI 1 t ' , _ T`� �lI i ii II Ii 11 CATV> A Dow ---------- WITH FAN Box _q WPMI 10 � PB USE IN -BOX H' FOR BRICK OUTSIDE EF ELECTRICAL . BEDROOM 2A PLAN 1 B4� 3 2 GENERAL NOTES: 1. CODE: 1./. COMPLY WITH 'INDIANA ELECTRICAL CODE AND ALL APPLICAPABLE FEDERAL, STATE, AND LOCAL CODES AND STANDARDS. 2. WORK: 2.1. PROVIDE A COMPLETE, FUNCTIONING SYSTEM. 2.2. CONSULT WITH LOCAL ELECTRIC UTILITY COMPANY. 2.3. PROVIDE ALL MATERIAL AND LABOR AND PAY ALL FEES. 2.4. COORDINATE ALL ELECTIRCAL WORK WITH ALL OTHER BUILDING TRADES. 2.5. SEE FRAMING PJWS FOR BORING AND NOTCHING NOTES. 3. MAIN DISTRIBUTION PANEL: 3.1. PROVIDE ELECTRICAL PANEL WITH COPPER BUS. 3.2. WIRING ON THE LOAD SIDE OF THE PANEL IS TO BE COPPER, SERVICE SIOE CAN BE ALUMINUM. 3.3. LABEL ALL ELECTRICAL CIRCUITS AT MAIN PANEL BOX. 3.4. OCCUPANTS MUST HAVE ACCESS TO THEIR OWN DISCONNECTING SERVICE. 4. BRANCH CIRCUITS: 4.1. PROVIDE COPPER BRANCH CONDUCTORS. ALUMINUM CONDUCTORS ARE NOT ALLOWED. PROVIDE CABLE WITH 12/2 CONDUCTOR AND GROUND, MINIMUM. 4.2. CIRCUITS AND CONDUCTORS: SIZE OF CIRCUIT SIZE OF CONDUCTOR 15 AMP: /12 20 AMP: /12 30 AMP: #10 40 AMP: 111 8 50 AMP: f 6 60 MMP: 4 4.3. INSTALL WALL DUPLEX RECEPTACLES SO THE DISTANCE FROM THE FLOOR TO CENTER OF THE LOWER RECEPTACLE IS AT LEAST 15 A.F.F. 4.4. STAGGER RECEPTACLE OUTLETS 2'-0" WHEN IN SAME WALL SERVING ADJACENT ROOMS OR UNITS. 4.5. PROVIDE GFI RECEPTACLES FOR ALL COUNTER TOP RECEPTACLES IN KITCHEN (EXCEPT FOR RANGE AND REFRIGERATOR) AND BATHROOM. EQUALY DIVIDE COUNTERTOP RECEPTACLE LOADS AND PLACE ON TWO SEPARATE APPLIANCE CIRCUITS. 4.6. ALL I15/120V ELECTRICAL DUPLEX RECEPTACLES IN DINING AREA MUST BE ON SMALL APPLIANCE CIRCUITS. RANGE HOOD FAN IS NOT TO BE WIRED INTO THE SMALL APPLIANCE CIRCUITS. 5. LIGHTING: 5.1. PROVIDE LIGHT FIXTURES, RANGE HOOD EXHAUST FAN. BATHROOM FAN/LIGHTS AND ALL OTHER ELECTRICAL FIXTURES, MECHANICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING DUCTWORK TO ALL EXHAUST FANS. 5.2. SEE A612 FOR LIGHTING FIXTURE TYPES DESIGNATED AS -A", "B", ETC. 5.3. ALL LIGHT FIXTURES IN CLOSETS MUST BE 12" FROM THE EDGE OF ALL CLOSET RACKS. 5.4. MOUNT BEDROOM LIGHTS ON CEILING FAN BOXES FOR FUTURE CEILING FAN INSTALLATION. USE 3 -CONDUCTOR PLUS GROUND CABLE FROM SWITCH TO LIGHT. ADD (1) DUMMY SWITCH. 5.5. SET WALL SWITCHES, FAN SWITCHES AND THERMOSTATS AT 4'-0" A.F.F. 6. SMOKE DETECTORS: 6.1. HARD WIRE ALL SMOKE DETECTORS TOGETHER. 7. RECEP'ACLES WILL BE TESTED FOR VOLTAGE DROP; ANY VOLTAGE DROP GREATER THAN 6% WILL BE REJECTED. SPECIFIC NOTES: 1. PROVIDE JUNCTION BOX FOR DISPOSER. LOCATE SWITCH ABOVE COUNTER TOP. PROVIDE 2' PIGTAIL CONNECTION TO DISPOSER. 2. FLUSH MOUNTED EXHAUST FAN IN CEILINGS. 3. RANGE RECEPTACLE: 50A, (3)#'8, (1)#'10 GROUND. 4. RECEPTACLE FOR EXHAUST HOOD. PLACE AT HEIGHT REQUIRED BY MANUFACTURER. 5. NOT USED 6. WASHER RECEPTACLE: 20A, 120V, 1 POLE CIRCUIT. 7. DRYER RECEPTACLE: 30A, 24OV, 2 POLE CIRCUIT. 8. REFRIGERATOR RECEPTACLE ON SEPARATE CIRCUIT. 9. ELECTRIC FURNACE DISCONNECT: 10,000W, 60A, 240V. 2 POLE CIRCUIT. 10. DOOR CHIME WITH PUSH BUT70N AND TRANSFORMER. 11. RECEPTACLE FOR UNDER -COUNTER DISHWASHER. 12. CEILING SMOKE DETECTOR. WHERE MULTIPLE SMOKE DETECTORS ARE INSTALLED, CONNECT AUDIBLE FUNCTIONS TOGETHER SO IF ONE ALARM SOUND, ALL SOUND. 13. NOT USED 14. NOT USED. 15. NOT USED. 16. NOT USED. 17. EMERGENCY STROBE LIGHT AND HORN CONNECTED TO 12VDC TRANSFORMER CONNECTED TO EMERGENCY PULL CHAIN SWITCHES IN RESTROOMS. SEE ALSO SHEET A612. 1 the, U studio... w COPYRIGHT & OWNERSHIP 0- 30CUMENTSTS 9R4TJfd � sA DAV13 r: U; �Z AS00033004 J 1 •. BrA7EaF } DATE: 03.10.2016 PROJECT NO.: 16002 CAD REFERENCE NO. ACA 2016 PLOT REFERENCE N0. SEE LOWER LEFT DRAWNG SCALE SEE DRAWING vevaas 04.21.17 RENEW SET 0505.17 BID SET UH -10-N 04 .aTi�i�n county �'ea tg^.M10-,cetlMr<ioaT+en- w CT mt_ U co Zz � CL wL; z �Q O W LL w W QO OC��� 2 9F1r'1111 1 B ELECTRICAL Q PLAN s T wnem E411