Loading...
HomeMy WebLinkAbout17080193.68S C DISC UNIT VV/ CONNECT USE IN -BOX FAN BOX LOCATED AT FOR BRICK ® BRICK WAINSCOTT GF OUTSIDE G. € 200 AMP PANEL W/ �. _ W/ D'SCONECT CAN[ WATER HEATER WIRE A / 1 PER MANJFACTURERRECOMM TE_ FURNACE WIRE P \ € _ __. , FURNACE WIRE PER \ ` - _ MANUFACTURER � RECOVMENOATO!V FAN BOX SD B W rT _ FAN BOX IT �-- I c I T 1 CAN ` DISHWxSTtETF'- F�l TEL i -- -- r �- _----------- _ ______. ELEC. - — RANGE ...Fi a\\ RANGEOOD HI `�\ W/LIGHT {yQ/-/ REFRIGERATOR (DUCTED) R"E �. SF: 1 l W / CAN GFI TEL 7 USE IN-BO%�L OR UTSDEC/ T i 1 SECOND FLOOR ELECTRICAL PLAN FIRST FLOOR ELECTRICAL PLAN SCALE: , /. -, -0 SCALE: 1/4'=,'-0' 5 4 3 2 ELECTRICAL SYMBOLS LEGEND MARK DESCRPTtON U az~a J LLL W LLJN O 115 VOLT DUPLEX OUTLET Q 220/240 VOLT OUTLET (10) Qp GH 115 VOLT OUTLET (GROUND FAULT RTTERUPT) V W7 115 VOLT OUTLET 3 BOX (WEATHERPROOF OF) ARJNCTON CAT/DHBC LIGHT SWITCH 3 -WAY SAI 1 TELEPHONE OUTLE- J❑ JUNCTION BOX EP FUSED DISCONNECT ❑— CABLE T.V. OUTLET Q THERMDSTA? - SEE MECHANICAL PLAN FOR LOCATION 0 SMOKE DETECTOR EXHAAIST FAN (VENT THRU ROOF OR WALL) CIRCUIT BREAKER PANE BOX O 54• AF.F. C I DOOR BEL ® GARAGE OVERHEAD OR OPENER OC GARAGE OVERHEAD DOOR BUTTON O CARBON MONOXIDE DETECTOR ELECTRICAL NOTES 1. CONSULT WITH LOCAL ELECTRIC UTILFY COMPANY. PROVIDE ALL MATERIAL h LABOR k PA" Al FEES NOT PAID 9Y LOCAL UTIUTY COMPANY. L ALL ELECTRICAL WORK PERFORMED ON THS JOB WLL BE COORDINATED WITH ALL OTHER BUILDING TRADES AND IS TO BE ASTALLED IN ACCORDANCE WITH AL_ EXISTING LOCAL. STATE AND FEDRAL ,^ ,ODES AND STANDARDS (LATEST EDITION) TO INSURE A OOMPLEE AND OPERABLE JOB. 3. ALL COUNTER -Dp OUTLETS IN KITCHEN AND BATHROOM TO BE GF RATED EXCEPT FOR RANGE AND REFRIGERATOR. 4. AL_ BRANCH CONOUC-ORS TO BE COPPER. NO ALUMINUM WIRING A_LOWED. MINIMUM ELEC. WIRE SIZE 12/2 W/ GROUND. 5. OCCUPANTS SHALL HAVE ACCESS TO THEIR OWN DtSCONNECTNG SERVICE. 6. LIGHT FlX'URES, RANGE HOOD EXHAUST FAN, BATHROOM FAN / LIGHT TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. DUCTWORK TO BE FURNISHED AND 'NSTAIED BY MECNANIGAL CONTRACTOR 7. ALL 11 5/120 V ELECTRICAL DUPLEX OUTLETS IN THE DINING AREA MUST BE ON SMALL APPLIANCE CIRCUTS. RANGE H0OD FAN IS NOT TO BE WIRED INTO THE SMALL APPLIANCE CIRCUITS. 8. WIRING ON THE LOAD SIDE OF THE PANEL IS TO BE COPPER, SERVICE SIDE CAN BE ALUMINUM. 10. WALL DUPLEX RECEPTACLES SHALL BE PLACED SO THAT THE DISTANCE FROM THE FLOOR TO CENTER OF THE LOWER RECEPTACLE IS AT LEST 15'• A.F.F. 11. WALL SWITCHES. FAN SWITCHES AND THERMOSTATS SHALL BE SET AT 4'-0" A.F.F. 12. SIZE OF CIRCUIT SIZE OF WIRE 15 AMP. 12 20 AMP. 2 30 AAP. 10 AO AMM`. 8 50 AMP. 1 6 13. CONTRACTOR TO STAGGER RECEPTACLE OUTLETS, 2'-0', IN SAME WALL SERVING ADJACENT ROOM/UNITS. 15. ELECTRICAL PANEL SHALL HOVE COPPER BUS. 16. ALL ELECTRICAL CIRCUITS ARE TO BE _ABELED AT UNIT PANEL BOX. 17. SEE SHEET A7.1 FOR BORING AND NOTCHING NOTES. 18. ALL LIGHT FIXTURES IN CLOSETS MUST BE 12• FROM -FL EDGE OF AL CLOSET WICKS. 19. INSTAL LIGHT SWITCHES NO HIGHER THAN 48• AF.F. AND ELECTRICAL OUTLETS NO LOWER THAN 15' AF.F. IN ALL UNITS. 20. BEDROOM LIGHT TO BE MOUNTED ON FAN BOXES FOR FLTUR= CEIUNG FAN INSTALLATION WIRING FROM SWITCH TO UGHT TO BE 3 -CONDUCTOR PLUS GROUND ADO A DUMMY SWITCH 21. EQUALLY DMDE COUNTERTOP REECEPTACLE LOADS AND AND PLACE ON TWO SEPARATE APPUCANCE CIRCUITS 22. AL SMOKE DETECTORS TO BE HARD WIRED AND TIED TOGETHER. the, 0 U U studio... U LU COPYRIGHT 4 OWNERSHIP 0% DOCUMENTS Xt vourrlE _I 1 t A DAVID T tfilOEQ DATE 0110.2016 PRO.ECT NO.: 16002 CAD REFERENCE NO. ACA 2016 PLOT REFERENCE N0. SEE LOWER LEFT DRAWING SCALE SEE DRAWING W[wsaa 04.21.17 REVIEW SET 05.05.17 BID SET Uin_\ D LLI U az~a J LLL W LLJN O LU Q �`j/',, (D U) Z Ln Z CD _ W LLI C-) SHEET Wnt SINGLE FAMILY Q ELECTRICAL PLAN E431