HomeMy WebLinkAbout17080193.69(PROVIDE FOR FUTURE USE) WATER SOFTENER BY-PASS 4E DETAIL PLUMBING 1 BEDROOM - TYPE B - ISOMETRIC VIEW 5A1/4'- 4B 5 4 3'x2" REDUCER OPEN SIG47 DRAIN 3EDETAIL 6'C.O. NOM E BUIDING PLUMBING LEGEND MARL DESCRIPTION REMARKS C.O. CLEANOUT: AT ENDS OF ALL RUNS (SEE PLAN) F.D. FLOOR DRAIN H.B. HOSE BIBB: (2) PER BUILDING, 1 FRONT, 1 BACK 1 L -i LAVATORY: t, 3 O.S.D. OPEN SITE DRAIN: FOR FURNACE CONDENSATE UNE OR WATER SOFTENER (IN WAL. ,SEE DETAIL 3E/P411) SK -1 SINK: KITCHEN 1, 3 SH -1 SHOWER: LASCO 1483 -CST 1, 3 SH -2 SHOWER: LASCO 1363-WSC 1, 3 WC -1 WATER CLOSET: ACCESSIBLE HEIGHT 1, 2 W.H. WATER HEATER: AO. SMITH ECS -40 1 W.H.-2 WATER HEATER (TYPE 'A' LIMIT): LOWBOY 40 GALLON ELECTRIC 1 1. SEE MATERIAL SCHEDULE ON SHEET A612 FOR MORE INFORMATION. 2. ALWAYS MOUNT TRIP LEVER ON OPEN, WIDE SIDE OF TOILET (SIDE OPPOSITE NEAREST SIDE WALL). WHERE FLUSH CONTROL NEEDS TO BE ON RIGHT HAND SIDE, PROVIDE RIGHT HAND TRIP LEVER. 3. FAUCETS: GENERAL CONTRACTOR HAS THE OPTION OF INSTALLING EITHER LISTED FIXTURES WITH AERATORS OR SELECTING DIFFERENT LOW FLOW FIXTURES AS LONG AS THE END RESULT IS A SHOWER HEAD WITH 1.75 GPM OR BETTER, KITCHEN FAUCET WITH 1.5 GPM OR BETTER, AND BATHROOM FAUCET WITH 1.5 GPM OR BETTER. PLUMBING BEDROOM - TYPE B 2A PLAN 3 2 GENERAL NOTES: I. COMPLY WITH INDIANA PLUMBING CODE AND ANY APPLICABLE NATIONAL AND LOCAL CODES AND ORDINANCES. 2. PROVIDE INDIVIDUAL WATER SUPPLY SHUT OF VALVES AND CODE APPROVED TRAPS FOR ALL PLUMBING FIXTURES. PROVIDE CHROME PLATED PIPE FOR ALL EXPOSED PIPING. 3. NOT USED 4. SUBMIT SUPPLY PIPING DIAGRAM PRIOR TO INSTALLATION W OF ANY PIPE. 5. FOR DOMESTIC WATER PIPING, USE AOUAPEX TUBING AND FITTINGS AS MANUFACTURED BY WIRS80 BE -OW GRADE INSIDE FOUNDATIONS AND ABOVE SLAB 6. FOR ALL SANITARY WASTE AND VENT PIPING, USE SCHEDULE 40 PVC OR HUBLESS CAST IRON. 7. FOR ALL PLUMBING FIXTURES, INSTALL WITH APPROVED BACKFLOW PREVENTION DEVICES. B. DO NOT INSTALL PIPING DIRECTLY OVER ELECTRICAL POWER DISTRIBUTION CABINETS. CONFIRM PANEL LOCATIONS PRIOR TO PIPING INSTALLATION. 9. FOR SINGLE RUNOUT$ TO PLUMBING FIXTURES, USE SAME SIZE AS ON THE PLUMBING FIXTURE SCHEDULE UNLESS OTHERWISE NOTED. 10. PROVIDE P -TRAPS FOR ALL DRAINS. 11. ADJUST SUPPLY LINE WALL PENETRATION HEIGHTS AS NEEDED TO AVOID CONFLICTS BETWEEN PLUSH VALVES AND GRAB BAR MOUNTING HEIGHTS. GRAB BAR HEIGHTS TAKE PRIORITY. 12. INSULATE EXPOSED SUPPL" AND DRAIN LINES AT ACCESSIBLE TOILET ROOMS AND KITCHENS WHERE NO 0 BASE CABINET OCCURS BENEATH A LAVATORY OR SINK. 13. PROVIDE EVERY ITEM ASSOCIATED WITH THE PLUMBING SYSTEM. PROVIDE TOILETS AND SEATS, SHOWER UNITS. DATE: 03.10.2016 KITCHEN SINKS, GARBAGE DISPOSALS. WATER HEATERS, PRO.,ECT NO.: 16002 FAUCETS, AND DRAINS. SUBMIT LITERATURE FOR ALL CAO REFERENCE k0. ACA 2016 ITEMS TO THE ARCHITECT FOR APPROVAL BEFORE PURCHASING. PLOT REFERENCE NO. SEE LOWER LEFT 14. PROVIDE LABOR AND MATERIAL TO CONNECT ALL DRAWING SCALE SEE DRAWING FIXTURES TO WATER SUPPLY AND ALL DRAINS TO THEoia CITY SEWER. 04.21.17 RENEW SET 05.05.17 RID SET U i D tiam�nc� c.x,,..; n•ec NeloNoo,.*om no,2r,P�1 the. 0 U studio... V +w am�ae.a�.+ewre�::w va�s.la:.me COPYRIGI-.T g OWNERSHIP OF DOCUMENTS �wyJ�T 0� S AFOD033004 € "N�Tp f C 15. SEE STRUCTURAL DRAWINGS FOR BORING AND NOTCHING NOTES. 16. PROVIDE AN ACCESSIBLE MASTER SHUT-OFF VALVE LOCATED BY THE WATER HEATER OR WATER SOFTENER. 17. PLACE VENTS ON BACK SIDE OF ROOFS AND PAINT BLACK. 18. ATTACH LAUNDRY SUPPLY AND DRAIN BOX TO STUD. 19, DO NOT CAULK TOILET BASE. 20. FOR ALL TOILETS, PROVIDE HANDLES ON OPEN SIDE (SAE OPPOSITE WALL NEAREST SIDE OF TOILET) OF THE FIXTURE. 21. POSITION ALL OPEN SITE DRAINS (OSD) SO PIPING RUNS THROUGH STUD WALE: SEE DETAIL 3E/P411. 22. POSITION ALL WASHERS ON LEFT SIDE OF DRYER; SEE UNIT FLOOR PLANS. 23. SET FLOOR DRAINS PRIOR TO POURING FLOOR SLAB. 24. ANY VOIDS IN FLOOR UNDER SHOWER OR BATHTUB MUST BE FILLED WITH CONCRETE FULL DEPTH ON PROPER BOX PROVIDED. 25. WATER LINE BETWEEN METER AND INSIDE BUILDING MUST BE CONTINUOUS; NO FITTINGS 26. USE LOW F_OW DEVICES FOR KITCHENS, BATH, LAVATORY. AND SHOWER FAUCETS. 27. INDIVIDUALLY VENT ALL PLUMBING FIXTURES; GANG VENTING OF INDIVIDUAL UNIT VENTS INTO ONE COMMON VENT IS PROHIBITED. 28. SEE SHEET P411 FOR PLUMBING FIXTURE LEGEND, ACCESSORY LEGEND. AND OSO RISER DETAIL 29. PRESSURE TEST ALL WATER LINES BEFORE INSTALLING GYPSUM BOARD. 30. NOT USED m 31. PROVIDE AIR CHAMBER, FULL PIPE SIZE, AT EACH HOT AND COLD WATER CONNECTION, 18" LONG. 32. PROPERLY CAULK AND/OR FIRE STOP ALL PLUMBING PENETRATIONS AND GAPS THROUGH WALLS AND SLAB. 33. PROVIDE 1"0 WATER LINE TO EACH UNIT. THE WATER UNE BETWEEN WATER METER AND INSIDE BUILDING MUST BE CONTINUOUS, NO FITTINGS. 34. SEE SHEET S531 FOR RADON VENT DETAILS AND NOTES. 35. INSULATE EXPOSED HOT WATER WATER HEATER PIPING. ADD ALTERNATE ITEMS: ADO 1: ADD SCALE BLASTER TO UNITS. 0 = CT m W 0 U) QZ�z JW=o 0 Ln Z O LU w w QO 000 2 s ❑Tt 113R PLUMBING PLAN P411