HomeMy WebLinkAbout17080193.69(PROVIDE FOR FUTURE USE)
WATER SOFTENER BY-PASS
4E DETAIL
PLUMBING
1 BEDROOM - TYPE B - ISOMETRIC
VIEW
5A1/4'-
4B
5 4
3'x2" REDUCER
OPEN SIG47 DRAIN
3EDETAIL
6'C.O.
NOM E
BUIDING
PLUMBING LEGEND
MARL DESCRIPTION REMARKS
C.O. CLEANOUT: AT ENDS OF ALL RUNS (SEE PLAN)
F.D. FLOOR DRAIN
H.B. HOSE BIBB: (2) PER BUILDING, 1 FRONT, 1 BACK 1
L -i LAVATORY: t, 3
O.S.D. OPEN SITE DRAIN: FOR FURNACE CONDENSATE UNE OR WATER SOFTENER (IN WAL.
,SEE DETAIL 3E/P411)
SK -1 SINK: KITCHEN 1, 3
SH -1 SHOWER: LASCO 1483 -CST 1, 3
SH -2 SHOWER: LASCO 1363-WSC 1, 3
WC -1 WATER CLOSET: ACCESSIBLE HEIGHT 1, 2
W.H. WATER HEATER: AO. SMITH ECS -40 1
W.H.-2 WATER HEATER (TYPE 'A' LIMIT): LOWBOY 40 GALLON ELECTRIC 1
1. SEE MATERIAL SCHEDULE ON SHEET A612 FOR MORE INFORMATION.
2. ALWAYS MOUNT TRIP LEVER ON OPEN, WIDE SIDE OF TOILET (SIDE OPPOSITE
NEAREST SIDE WALL). WHERE FLUSH CONTROL NEEDS TO BE ON RIGHT HAND SIDE,
PROVIDE RIGHT HAND TRIP LEVER.
3. FAUCETS: GENERAL CONTRACTOR HAS THE OPTION OF INSTALLING EITHER
LISTED FIXTURES WITH AERATORS OR SELECTING DIFFERENT LOW FLOW FIXTURES
AS LONG AS THE END RESULT IS A SHOWER HEAD WITH 1.75 GPM OR BETTER,
KITCHEN FAUCET WITH 1.5 GPM OR BETTER, AND BATHROOM FAUCET WITH 1.5 GPM
OR BETTER.
PLUMBING
BEDROOM - TYPE B
2A PLAN
3 2
GENERAL NOTES:
I. COMPLY WITH INDIANA PLUMBING CODE AND ANY
APPLICABLE NATIONAL AND LOCAL CODES AND
ORDINANCES.
2. PROVIDE INDIVIDUAL WATER SUPPLY SHUT OF VALVES
AND CODE APPROVED TRAPS FOR ALL PLUMBING
FIXTURES. PROVIDE CHROME PLATED PIPE FOR ALL
EXPOSED PIPING.
3. NOT USED
4. SUBMIT SUPPLY PIPING DIAGRAM PRIOR TO INSTALLATION W
OF ANY PIPE.
5. FOR DOMESTIC WATER PIPING, USE AOUAPEX TUBING
AND FITTINGS AS MANUFACTURED BY WIRS80 BE -OW
GRADE INSIDE FOUNDATIONS AND ABOVE SLAB
6. FOR ALL SANITARY WASTE AND VENT PIPING, USE
SCHEDULE 40 PVC OR HUBLESS CAST IRON.
7. FOR ALL PLUMBING FIXTURES, INSTALL WITH APPROVED
BACKFLOW PREVENTION DEVICES.
B. DO NOT INSTALL PIPING DIRECTLY OVER ELECTRICAL
POWER DISTRIBUTION CABINETS. CONFIRM PANEL
LOCATIONS PRIOR TO PIPING INSTALLATION.
9. FOR SINGLE RUNOUT$ TO PLUMBING FIXTURES, USE
SAME SIZE AS ON THE PLUMBING FIXTURE SCHEDULE
UNLESS OTHERWISE NOTED.
10. PROVIDE P -TRAPS FOR ALL DRAINS.
11. ADJUST SUPPLY LINE WALL PENETRATION HEIGHTS AS
NEEDED TO AVOID CONFLICTS BETWEEN PLUSH VALVES
AND GRAB BAR MOUNTING HEIGHTS. GRAB BAR HEIGHTS
TAKE PRIORITY.
12. INSULATE EXPOSED SUPPL" AND DRAIN LINES AT
ACCESSIBLE TOILET ROOMS AND KITCHENS WHERE NO 0
BASE CABINET OCCURS BENEATH A LAVATORY OR SINK.
13. PROVIDE EVERY ITEM ASSOCIATED WITH THE PLUMBING
SYSTEM. PROVIDE TOILETS AND SEATS, SHOWER UNITS. DATE: 03.10.2016
KITCHEN SINKS, GARBAGE DISPOSALS. WATER HEATERS, PRO.,ECT NO.: 16002
FAUCETS, AND DRAINS. SUBMIT LITERATURE FOR ALL CAO REFERENCE k0. ACA 2016
ITEMS TO THE ARCHITECT FOR APPROVAL BEFORE
PURCHASING. PLOT REFERENCE NO. SEE LOWER LEFT
14. PROVIDE LABOR AND MATERIAL TO CONNECT ALL DRAWING SCALE SEE DRAWING
FIXTURES TO WATER SUPPLY AND ALL DRAINS TO THEoia
CITY SEWER.
04.21.17 RENEW SET
05.05.17 RID SET
U i D
tiam�nc� c.x,,..; n•ec NeloNoo,.*om no,2r,P�1
the. 0
U
studio...
V
+w am�ae.a�.+ewre�::w va�s.la:.me
COPYRIGI-.T g OWNERSHIP OF DOCUMENTS
�wyJ�T
0�
S
AFOD033004 €
"N�Tp f C
15. SEE STRUCTURAL DRAWINGS FOR BORING AND NOTCHING
NOTES.
16. PROVIDE AN ACCESSIBLE MASTER SHUT-OFF VALVE
LOCATED BY THE WATER HEATER OR WATER SOFTENER.
17. PLACE VENTS ON BACK SIDE OF ROOFS AND PAINT
BLACK.
18. ATTACH LAUNDRY SUPPLY AND DRAIN BOX TO STUD.
19, DO NOT CAULK TOILET BASE.
20. FOR ALL TOILETS, PROVIDE HANDLES ON OPEN SIDE
(SAE OPPOSITE WALL NEAREST SIDE OF TOILET) OF
THE FIXTURE.
21. POSITION ALL OPEN SITE DRAINS (OSD) SO PIPING
RUNS THROUGH STUD WALE: SEE DETAIL 3E/P411.
22. POSITION ALL WASHERS ON LEFT SIDE OF DRYER; SEE
UNIT FLOOR PLANS.
23. SET FLOOR DRAINS PRIOR TO POURING FLOOR SLAB.
24. ANY VOIDS IN FLOOR UNDER SHOWER OR BATHTUB
MUST BE FILLED WITH CONCRETE FULL DEPTH ON
PROPER BOX PROVIDED.
25. WATER LINE BETWEEN METER AND INSIDE BUILDING
MUST BE CONTINUOUS; NO FITTINGS
26. USE LOW F_OW DEVICES FOR KITCHENS, BATH,
LAVATORY. AND SHOWER FAUCETS.
27. INDIVIDUALLY VENT ALL PLUMBING FIXTURES; GANG
VENTING OF INDIVIDUAL UNIT VENTS INTO ONE COMMON
VENT IS PROHIBITED.
28. SEE SHEET P411 FOR PLUMBING FIXTURE LEGEND,
ACCESSORY LEGEND. AND OSO RISER DETAIL
29. PRESSURE TEST ALL WATER LINES BEFORE INSTALLING
GYPSUM BOARD.
30. NOT USED m
31. PROVIDE AIR CHAMBER, FULL PIPE SIZE, AT EACH HOT
AND COLD WATER CONNECTION, 18" LONG.
32. PROPERLY CAULK AND/OR FIRE STOP ALL PLUMBING
PENETRATIONS AND GAPS THROUGH WALLS AND SLAB.
33. PROVIDE 1"0 WATER LINE TO EACH UNIT. THE WATER
UNE BETWEEN WATER METER AND INSIDE BUILDING
MUST BE CONTINUOUS, NO FITTINGS.
34. SEE SHEET S531 FOR RADON VENT DETAILS AND
NOTES.
35. INSULATE EXPOSED HOT WATER WATER HEATER PIPING.
ADD ALTERNATE ITEMS:
ADO 1: ADD SCALE BLASTER TO UNITS.
0
= CT m
W
0 U)
QZ�z
JW=o
0 Ln Z
O
LU w w
QO
000
2
s ❑Tt
113R PLUMBING PLAN
P411