HomeMy WebLinkAbout17080193.70(PROVIDE FOR FJTURE USE)
WATER SOFTENER BY-PASS
4E DETAIL
L
5
PLUMBING
1 BEDROOM - TYPE A - ISOMETRIC
VIEW
5A 1/4--1. 4• 6.
1:48
4
3"x2" REDUCER
e
2" W
FLOOR LINE
OPEN SIGI- DRAIN
E
3DETAIL
PLUMBING LEGEND
MARK DESCR-7ION RBWRKS
C.O. CLEANOUT: AT ENDS OF ALL RUNS (SEE PLAN)
F.D. FLOOR DRAIN
H.B. HOSE 0188: (2) PER BUILDING, 1 FRONT, i BACK 1
L-1 LAVATORY: 1, 1
O.S.D. OPEN STIT DRAW: FOR FURNACE CONDENSATE UNE OR NATER SOFTENER (IN WAL.,
SEE DETAIL 3E/P411)
SK -1 SINK: KITCHEN 1, 3
SH-' SHOWER: (ASCO 1493 -CST 1, 3
SH -2 SHOWER: LASCO 1363 -BM 1, 3
WC -i WATER CLOSET: ACCESSIBLE HOGHT 1, 2
W.N. WATER HEATER: A0. SMITH ECS -40 1
W.H.-2 WATER HEATER (PPE 'A' UNIT): LOWBOY 40 GALLON ELECTRIC 1
1. SEE MATERIAL SCHEDULE ON SHEET A612 FOR MORE INFORMATION.
2. ALWAYS MOUNT TRIP LEVER ON OPEN, WIDE SIDE OF TOILET (SIDE OPPOSITE
NEAREST SIDE WALL). WHERE FLUSH CONTROL NEEDS TO BE ON RIGHT HAND SIDE,
PROVIDE RIGHT HAND TRIP LEVER.
3. FAUCETS• GENERAL CONTRACTOR HAS THE OPTION OF INSTALLING EITHER
LISTED FIXTURES WITH AERATORS OR SELECTING DIFFERENT LOW FLOW FIXTURES
AS LONG AS THE END RESULT IS A SHOWER HEAD WITH 1.75 GPM OR BETTER,
KITCHEN FAUCET WITH 1.5 GPM OR BETTER, AND BATHROOM FAUCET WITH 1.5 GPM
OR BETTER.
I.
I
WASHER`'
PLUMBING
I BEDROOM - T�PE A
2A N
1 4�.
�8
3 2
< END OF
ING ONLY
WHT WWE
1 B TYD: 'A'
Q PLUMBING PLAN
P412
GENERAL NOTES:
1.
COMPLY N'I-H INDIANA PLUMBING CODE AND ANY
APPLICABLE NATIONAL AND LOCAL CODES AND
ORDINANCES.
2.
PROVIDE INDIVIDUAL WATER SUPPLY SHUT OF VALVES
AND CODE APPROVED TRAPS FOR ALL PLUMBING
FIXTURES. PROVIDE CHROME PLATED PIPE FOR ALL
EXPOSED PIPING.
WEstudio...
3.
NOT USED
4.
SUBMIT SUPPLY PIPING DIAGRAM PRIOR TO INSTALLATION
W
OF ANY PIPE.
5.
FOR DOMESTIC WATER PIPING, USE AOUAPEX TUBING
COPYRIGHT k OWNERSHIP OF DOCUMENTS
AND FITTINGS AS MANUFACTURED BY WIRSBO BELOW
GRADE INSIDE FOUNDATIONS AND ABOVE SLAB
6.
FOR ALL SANITARY WASTE AND VENT PIPING, USE
SCHEDULE 40 PVC OR HUBLESS CAST IRON.
7.
FOR ALL PLUMBING FIXTURES, INSTALL WITH APPROVED
BACKFLOW PREVENTION DEVICES.
s, v
8.
DO NOT INSTALL PIPING DIRECTLY OVER ELECTRICAL
POWER DISTRIBUTION CABINETS. CONFIRM PANEL
LOCATIONS PRIOR TO PIPING INSTALLATION.
9.
FOR SINGLE RUNOUTS TO PLJMBING FIXTURES, USE
SAME SIZE AS ON THE PLUMBING FIXTURE SCHEDULE
UNLESS OTHERWISE NOTED.
,y DAY10 T�
10.
PROVIDE P -TRAPS FOR ALL DRAINS.
W.
11.
ADJUST SUPPLY LINE WALL PENETRATION HEIGHTS AS
S
AFIDDOI_
NEEDED TO AVOID CONFLICTS BETWEEN FLUSH VALVES
AND GRAB BAR MOUNTING HEIGHTS. GRAB BAR HEIGHTS
N
TAKE PRIORITY.
NN10l�
12.
INSULATE EXPOSED SUPPLY AND DRAIN LINES AT
cl
ACCESSIBLE TOILET ROOMS AND KITCHENS WHERE NO
BASE CABINET OCCURS BENEATH A LAVATORY OR SINK.
13.
PROVIDE EVERY ITEM ASSOCIATED WITH THE PLUMBING
SYSTEM. PROVIDE TOILETS AND SEATS, SHOWER UNITS,
DATE. 03.10.2016
KITCHEN SINKS, GARBAGE DISPOSALS, WATER HEATERS,
PROJECT NO.: 16002
FAUCETS, AND DRAINS. SUBMIT -ITERATURE FOR ALL
ITEMS TO THE ARCHITECT FOR APPROVAL BEFORE
CAD REFERENCE N0. ACA 2016
PURCHASING.
PLOT REFERENCE NO. SEE LOWER LEFT
14.
PROVIDE LABOR AND MATERIAL TO CONNECT ALL
DRAWING SCALE SEE DRAWING
FIXTURES TO WATER SUPPLY AND ALL DRAINS TO THEs
CITY SEWER.
04.21.17 REMEW SET
15.
SEE STRUC*JRAL DRAWINGS FOR BORING AND NOTCHING
05.05.17 BID SET
NOTES.
16.
PROVIDE AN ACCESSIBLE MASTER SHUT-OFF VALVE
LOCATED BY THE WATER HEATER OR WATER SOFTENER.
17.
PLACE VENTS ON BACK SIDE OF ROOFS AND PAINT
BLACK.
18.
ATTACH LAUNDRY SUPPLY AND DRAIN BOX TO STUD.
19.
DO NOT CAULK T01_ET BASE.
20.
FOR ALL TOILETS, PROVIDE HANDLES ON OPEN SIDE
TT TT
-�
(SIDE OPPOSITE WALL NEAREST SIDE OF TOILET) OF
THE FIXTURE.
U j�
21.
POSITION ALL OPEN SITE DRAINS (OSD) SO PIPING
m"W""�'"h11°"Nwgeeemeoa DsMaPmenF
RUNS THROUGH STUD WALL; SEE DETAIL 3E/P411.
22.
POSITION ALL WASHERS ON LEFT SIDE OF DRYER; SEE
UNIT FLOOR PLANS.
23.
SET FLOOR DRAINS PRIOR TO POURING FLOOR SLAB.
24.
ANY VOIDS IN FLOOR UNDER SHOWER OR BATHTUB
MUST BE FILLED WITH CONCRETE FULL DEPTH ON
PROPER BOX PROVIDED.
25.
WATER LINE BETWEEN METER AND INSIDE BUILDING
MUST BE CONTINUOUS; NO FITTINGS
26.
USE LOW FLOW DEVICES FOR KITCHENS, RATH,
LAVATORY, AND SHOWER FAUCETS.
Uj
27.
INDIVIDUALLY VENT ALL PLUMBING FIXTURES; GANG
VENTING OF INDIVIDUAL UNIT VENTS INTO ONE COMMON
VENT IS PROHIBITED.
r l ^
0 0
� Q
28.
SEE SHEET P411 FOR PLUMBING FXTURE LEGEND,
Q Z Cn
ACCESSORY LEGEND. AND OSD RISER DETAIL
Q
29.
PRESSURE TEST AL_ WATER LINES BEFORE INSTALLING
/'1
C)
GYPSUM BOARD.
0
Q
- 0 _
m
30.
NOT JSED
1 1 1
LLI w L1.)
31.
PROVIDE AIR CHAMBER, FULL PIPE SIZE, AT EACH HOT
AND COLD WATER CONNECTION, 18" LONG.
Q
32.
PROPERLY CAULK AND/OR FIRE STOP ALL PLUMBINGO
r Q
r U
PENETRATIONS AND GAPS THROUGH WALLS AND SLAB.
33.
PROVIDE 1'0 WATER LINE TO EACH UNIT. THE WATER
T
i
UNE BETWEEN WATER METER AND INSIDE BUILDING
MUST BE CONTINUOUS, NO FITTINGS.
34.
SEE SHEET 5531 FOR RADON VENT DETAILS AND
NOTES.
35.
INSULATE EXPOSED HOT WATER WATER HEATER PIPING.
ADD ALTERNATE ITEMS:
AB01:
ADD SCALE BLISTER TO UNITS.
WHT WWE
1 B TYD: 'A'
Q PLUMBING PLAN
P412