HomeMy WebLinkAboutC104 SWPPP DETAILSDETAIL OF INLET
SEDIMENT CONTROL DEVICE
VELCRO CLOSURE
LIFT STRAPS USED
FOR EASY
MOVEMENT AND
INSPECTION OF UNIT
STORM SEWER GRATE
R
STORM
SEWER
GRATE
Ò
Ò
Mechanical Properties Test Method Units MARV
Grab Tensile Strength ASTM D 4632 kN (lbs)1.62 (365) X 0.89 (200)
Grab Tensile Elongation ASTM D 4632 %24 X 10
Puncture Strength ASTM D 4833 kN (lbs)0.40 (90)
Mullen Burst Strength ASTM D 3786 kPa (psi)3097 (450)
Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.51 (115) X 0.33 (75)
UV Resistence ASTM D 4355 %90
Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40)
Flow Rate ASTM D 4491 1/min/m (gal/min/ft )5907 (145)
Permittivity ASTM D 4491 Sec 2.1-1
22
Ò
Ò
RDANDY BAG
SILT FENCE INLET PROTECTION
INSTALLATION
1.DIG AN EIGHT-INCH DEEP, FOUR-INCH WIDE TRENCH AROUND THE PERIMETER OF THE
INLET.
2.IF USING PRE-ASSEMBLED GEOTEXTILE FABRIC AND POSTS, DRIVE THE POSTS INTO THE
SOIL, TIGHTLY STRETCHING THE GEOTEXTILE FABRIC BETWEEN POSTS AS EACH IS DRIVEN.
(POSTS MUST BE PLACED ON THE INLET SIDE OF THE ANCHOR TRENCH WITH THE
GEOTEXTILE FABRIC ON THE SIDE OF THE TRENCH FARTHEST FROM THE INLET.)
NOTE:IF ASSEMBLING THE GEOTEXTILE FABRIC AND POSTS ON-SITE, DRIVE THE POSTS INTO
THE SOIL AND THEN SECURE THE GEOTEXTILE FABRIC TO THE POSTS BY PLACING A PIECE
OF LATHE OVER THE FABRIC AND FASTENING IT TO THE POST
(STRETCHING THE FABRIC BETWEEN POSTS AS IT IS FASTENED).
3.USE THE WRAP JOIN METHOD WHEN JOINING POSTS.
4.PLACE THE BOTTOM 12 INCHES OF GEOTEXTILE FABRIC INTO THE EIGHT-INCH DEEP
TRENCH, LAYING THE REMAINING FOUR INCHES IN THE BOTTOM OF THE TRENCH AND
EXTENDING AWAY FROM THE INLET.
5.BACKFILL THE TRENCH WITH SOIL MATERIAL AND COMPACT IT IN PLACE.
6.BRACE THE POSTS BY NAILING BRACES INTO EACH CORNER POST OR UTILIZE RIGID
PANELS TO SUPPORT FABRIC.
NOTE: IN SITUATIONS WHERE STORM WATER MAY BYPASS THE STRUCTURE,
EITHER: SET THE TOP OF THE GEOTEXTILE FABRIC FILTER AT LEAST SIX INCHES LOWER THAN
THE GROUND ELEVATION ON THE DOWN-SLOPE SIDE OF THE STORM DRAIN INLET, BUILD A
TEMPORARY DIKE, COMPACTED TO SIX INCHES HIGHER THAN THE FABRIC, ON THE
DOWN-SLOPE SIDE OF THE STORM DRAIN INLET, AND/OR USE IN CONJUNCTION WITH
EXCAVATED DROP INLET PROTECTION.
MAINTENANCE
_ INSPECT DAILY.
_ INSPECT GEOTEXTILE FABRIC AND MAKE NEEDED REPAIRS IMMEDIATELY.
_ REMOVE SEDIMENT FROM POOL AREA TO PROVIDE STORAGE FOR THE NEXT STORM
EVENT. AVOID DAMAGING OR UNDERCUTTING FABRIC DURING SEDIMENT REMOVAL.
_ WHEN CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE SEDIMENT,
PROPERLY DISPOSE OF ALL CONSTRUCTION MATERIAL, GRADE AREA TO THE ELEVATION
OF THE STORM DRAIN INLET TOP, THEN STABILIZE IMMEDIATELY.
REFERENCED IN CHAPTER 7 PAGE 153-157 IN THE INDIANA STORM WATER QUALITY MANUAL.
SECURELY FASTEN
OVERLAPPING ENDS
OF SILT FENCE
MATERIAL TO
ADJACENT STAKES
WITH THREE WIRE
TIES OR OTHER
FASTENERS
ATTACH THE WOVEN
WIRE FENCE TO EACH
POST WITH THREE
WIRE TIES OR OTHER
FASTENERS
SILT FENCE MATERIAL
TO BE FASTENED
SECURELY TO WOVEN
WIRE FENCE WITH
THREE TIES SPACED
AT 3" ON CENTER
4"x8" TRENCH
STORM
SEWER
GRATE
REINFORCED
CORNERS
MANAGEABLE
2 FOOT
CONTAINMENT
AREA
LIFT
STRAPS
OPTIONAL
OVERFLOW
PORTS
DUMPING
STRAPS
STORM
INLET
DETAIL OF INLET SEDIMENT CONTROL DEVICE
Ô
Ô
Ô
Grab Tensile Strength ASTM D 4632 kN (lbs)1.78 (400) x 1.40 (315)
Grab Tensile Elongation ASTM D 4632 %15 x 15
Puncture Strength ASTM D 4833 kN (lbs)0.67 (150)
Mullen Burst Strength ASTM D 3786 kPa (psi)5506 (800)
Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.67 (150) x 0.73 (165)
UV Resistence ASTM D 4355 %90
Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40)
Flow Rate ASTM D 4491 1/min/m (gal/min/ft )2852 (70)
Permittivity ASTM D 4491 Sec 0.90-1
22
Ô
Grab Tensile Strength ASTM D 4632 kN (lbs)1.62 (365) X 0.89 (200)
Grab Tensile Elongation ASTM D 4632 %24 X 10
Puncture Strength ASTM D 4833 kN (lbs)0.40 (90)
Mullen Burst Strength ASTM D 3786 kPa (psi)3097 (450)
Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.51 (115) X 0.33 (75)
UV Resistence ASTM D 4355 %90
Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40)
Flow Rate ASTM D 4491 1/min/m (gal/min/ft )5907 (145)
Permittivity ASTM D 4491 Sec 2.1-1
22
Ô
RU
N
O
F
F
BLOCK AND AGGREGATE INLET SEDIMENT DEVICE
INSTALLATION
1.EXCAVATE THE FOUNDATION FOR THE CONCRETE BLOCKS ON LEVEL GRADE AND AT LEAST TWO INCHES BELOW THE TOP OF THE STORM DRAIN INLET.
2.PLACE THE BOTTOM ROW OF CONCRETE BLOCKS AROUND THE PERIMETER OF THE STORM DRAIN. LAY BLOCKS WITH OPENINGS FACING UP, ABUTTING
THE BLOCKS FIRMLY TOGETHER AND OVERLAPPING THE CORNERS.
3.IF NECESSARY, SUPPORT THE BLOCKS BY DRIVING SHARPENED 2 X 4 INCH WOOD STUDS OR REBAR (NOT MORTAR) THROUGH THE BLOCK OPENINGS
AND INTO THE UNDERLYING SOIL.
4.ON EACH SIDE OF THE BOTTOM ROW, TURN ONE CONCRETE BLOCK WITH ITS OPENINGS FACING HORIZONTALLY TO ALLOW FOR DEWATERING.
5.PLACE HARDWARE CLOTH OVER THE OPENINGS TO HOLD THE AGGREGATE IN PLACE.
6.PLACE THE FILTER MEDIUM (INDOT CA NO. 5 AGGREGATE) AROUND THE OUTSIDE OF THE CONCRETE BLOCKS TO CONTROL DRAINAGE RATE; LIMIT
FILTER MEDIUM SIDE SLOPES TO 2:1 RATIO OR FLATTER.
NOTE: IN SITUATIONS WHERE STORM WATER MAY BYPASS THE STRUCTURE, EITHER:
_ SET THE TOP OF THE CONCRETE BLOCKS AT LEAST SIX INCHES LOWER THAN THE GROUND ELEVATION ON THE DOWN-SLOPE SIDE OF THE STORM DRAIN
INLET,
_ BUILD A TEMPORARY DIKE, COMPACTED TO SIX INCHES HIGHER THAN THE CONCRETE BLOCKS, ON THE DOWN-SLOPE SIDE OF THE STORM DRAIN INLET,
AND/OR
_ USE IN CONJUNCTION WITH EXCAVATED DROP INLET PROTECTION (SEE EXCAVATED DROP INLET PROTECTION ON PAGE 145).
MAINTENANCE
_ INSPECT DAILY.
_ REMOVE SEDIMENT AND DEBRIS AND MAKE NEEDED REPAIRS IMMEDIATELY.
_ WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE AND PROPERLY DISPOSE OF ALL CONSTRUCTION MATERIAL AND SEDIMENT,
THEN STABILIZE.
CONCRETE BLOCKS (ONE CONCRETE
BLOCK, IN BOTTOM ROW OF BLOCKS
ON EACH SIDE OF STRUCTURE LAID
HORIZONTALY TO ALLOW FOR
DEWATERING
DETAIL OF INLET SEDIMENT CONTROL DEVICE
WITH CURB FILTER
STORM
GRATE
LIFT
STRAPS
CURB
FILTER
OPTIONAL
OUTFLOW
PORTS
DUMPING
STRAPS
CURB
OPENING
REINFORCED
CORNERS
MANAGEABLE
2 FOOT CONTAINMENT AREA
Ô
Ô
Ô
Grab Tensile Strength ASTM D 4632 kN (lbs)1.78 (400) x 1.40 (315)
Grab Tensile Elongation ASTM D 4632 %15 x 15
Puncture Strength ASTM D 4833 kN (lbs)0.67 (150)
Mullen Burst Strength ASTM D 3786 kPa (psi)5506 (800)
Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.67 (150) x 0.73 (165)
UV Resistence ASTM D 4355 %90
Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40)
Flow Rate ASTM D 4491 1/min/m (gal/min/ft )2852 (70)
Permittivity ASTM D 4491 Sec 0.90-1
2
Ô
Grab Tensile Strength 1.62 (365) X 0.89 (200)
Grab Tensile Elongation 24 X 10
Puncture Strength 0.40 (90)
Mullen Burst Strength 3097 (450)
Trapezoid Tear Strength 0.51 (115) X 0.33 (75)
UV Resistence 90
Apparent Opening Size 0.425 (40)
Flow Rate 5907 (145)
Permittivity 2.1
Ô
2
ASTM D 4632
ASTM D 4632
ASTM D 4833
ASTM D 3786
ASTM D 4533
ASTM D 4355
ASTM D 4751
ASTM D 4491
ASTM D 4491
kN (lbs)
%
kN (lbs)
kPa (psi)
kN (lbs)
%
Mm (US Std Sieve)
1/min/m (gal/min/ft )
Sec -1
2 2
C104
SW
P
P
P
D
E
T
A
I
L
S
w1
5
0
4
8
3
-
C
1
0
4
s
w
p
p
p
d
e
t
EDGE OF PAVEMENT
RUNO
F
F
RUNOFF
RU
N
O
F
F
RU
N
O
F
F
RUNOFF
EDGE OF PAVEMENT
FOR SAG INLETS LOCATIONS (NO SCALE)
MAINTENANCE
- INSPECT DAILY.
- REMOVE ACCUMULATED SEDIMENT FROM PAVED AREA (DO NOT FLUSH WITH WATER) AFTER
EACH STORM EVENT. DEPOSIT SEDIMENT IN AN AREA WHERE IT WILL NOT RE-ENTER THE PAVED
AREA OR STORM DRAINS.
- INSPECT FOR DAMAGE BY VEHICULAR TRAFFIC AND REPAIR IF NEEDED.
_ WHEN CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE SEDIMENT, PROPERLY
DISPOSE OF ALL CONSTRUCTION MATERIAL, GRADE AREA TO THE ELEVATION OF THE STORM
DRAIN INLET TOP, THEN STABILIZE IMMEDIATELY.
(NO SCALE)
FOR NON PAVED AREAS (NO SCALE)
POSTS: 2 X 4 WOODEN STAKE
FENCE: WOVEN WIRE, 14-1/2 GA., 6" MAX. MESH OPENING
FABRIC: IN ACCORDANCE WITH ASTM D 6461 LATEST EDITION.
GEOTEXTILE FABRIC LAID ON
DOWN-SLOPE SIDE AND
BOTTOM OF TRENCH
EXTEND WIRE FENCE A
MIN. OF 8" INTO GROUND
WOVEN WIRE FENCE
WITH SILT FENCE
MATERIAL COVER
CROSS BRACE
1"x2" or 1"x3"
36" MAX.
(TYP.)
DROP INLET
WITH GRATE
12
"
M
I
N
.
18
"
M
A
X
.
2"x2" OR 2"X4"
WOOD FRAME
2"x2" or 2"x4" STAKE
5' MIN.
OVERLAP
DANDY BAG
(NO SCALE)
(NO SCALE)
Ô
Ô
(NO SCALE)
INLET
AGGREGATE INDOT #5
RUNOFF
CONCRETE BLOCK LAID
HORIZONTAL FOR
DEWATERING
FILTERED WATER
HARDWARE CLOTH
FINISHED GRADE
2:1 SLOPE OR
FLATTER
AGGREGATEGRATED INLET
WIRE MESH
COCONUT MAT INLET PROTECTION
PLAN SECTION
RE
V
I
S
I
O
N
S
A
N
D
I
S
S
U
E
S
Pa
r
t
o
f
t
h
e
S
E
/
4
o
f
S
e
c
t
i
o
n
2
3
,
T
o
w
n
s
h
i
p
1
8
N
o
r
t
h
,
R
a
n
g
e
3
E
a
s
t
,
C
l
a
y
T
o
w
n
s
h
i
p
,
H
a
m
i
l
t
o
n
C
o
u
n
t
y
,
I
n
d
i
a
n
a
W15.0483
PR
E
P
A
R
E
D
F
O
R
:
12
4
2
W
E
S
T
1
3
6
T
H
S
T
R
E
E
T
,
C
A
R
M
E
L
,
I
N
4
6
0
3
2
PROJECT NO.
SHEET NO.
CH
E
C
K
E
D
B
Y
:
DR
A
W
N
B
Y
:
RL
W
DE
S
I
G
N
E
D
B
Y
:
DW
G
N
A
M
E
:
PR
O
J
E
C
T
N
O
.
:
W1
5
.
0
4
8
3
DA
T
E
BY
05
.
1
9
.
2
0
1
6
SS
R
DA
T
E
:
RL
W
EN
G
I
N
E
E
R
S
31
7
|
8
4
6
-
6
6
1
1
80
0
|
4
5
2
-
6
4
0
8
31
7
|
8
4
3
-
0
5
4
6
fa
x
W E I H E
La
n
d
S
u
r
v
e
y
i
n
g
|
C
i
v
i
l
E
n
g
i
n
e
e
r
i
n
g
La
n
d
s
c
a
p
e
A
r
c
h
i
t
e
c
t
u
r
e
AL
L
A
N
H
.
W
E
I
H
E
,
P
.
E
.
,
L
.
S
.
-
F
O
U
N
D
E
R
10
5
0
5
N
.
C
o
l
l
e
g
e
A
v
e
n
u
e
In
d
i
a
n
a
p
o
l
i
s
,
I
n
d
i
a
n
a
4
6
2
8
0
we
i
h
e
.
n
e
t
Know what's below.
before you dig.Call
R
TR
A
D
E
R
'
S
P
O
I
N
T
C
H
U
R
C
H
O
F
C
A
R
M
E
L
SU
B
M
I
T
T
E
D
F
O
R
I
N
I
T
I
A
L
R
E
V
I
E
W
12
.
1
8
.
2
0
1
5
ML
T
THE SITE DOES NOT LIE IN A SPECIAL FLOOD
HAZARD AREA AS ESTABLISHED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY - NATIONAL
FLOOD INSURANCE PROGRAM, WHEN PLOTTED
BY SCALE ON FLOOD INSURANCE RATE
#18057C207G, DATED NOVEMBER 19, 2014
FLOOD STATEMENT
STEVEN SCOTT RUCKER P.E. 11300279
SU
B
M
I
T
T
E
D
F
O
R
T
A
C
R
E
V
I
S
I
O
N
S
03
.
1
4
.
2
0
1
6
ML
T
NO EARTH DISTURBING
ACTIVITY MAY TAKE
PLACE WITHOUT AN
APPROVED STORM
WATER MANAGEMENT
PERMIT
NOTE
SU
B
M
I
T
T
E
D
F
O
R
D
R
A
I
N
A
G
E
A
P
P
R
O
V
A
L
04
.
2
0
.
2
0
1
6
ML
T
RE
V
I
S
E
D
F
O
R
D
R
A
I
N
A
G
E
A
P
P
R
O
V
A
L
05
.
1
2
.
2
0
1
6
ML
T
FI
N
A
L
C
O
N
S
T
R
U
C
T
I
O
N
P
L
A
N
S
05
.
1
9
.
2
0
1
6
ML
T