HomeMy WebLinkAboutC200 SITE PLANC C C C C C C C C C C C 136TH STREET 4 3 3 3 3 4 24 24 18 7 2 6 9 8 21 22222222 23 POND INFORMATION EXISTING:||PROPOSED: 2yr = 869.31 ||2yr = 867.78 10-yr = 869.82 ||10-yr = 868.47 100-yr = 870.31 ||100-yr = 869.79 SPILLWAY = NONE ||SPILLWAY = 869.80 POND INFORMATION PROPOSED: 2yr = 867.23 10-yr = 867.72 100-yr = 868.52 SPILLWAY = 869.20 P2 P2 P2 H1 H3 H4 S1 S2 TYP. S2 TYP. P1 P1 P1 P4 P4P2 P2 P2 S2 TYP. H5 A1 A1 A1 A1 A2 A2 A2 A2 A2 A2 H6 H6 P2 H2 TYP. H2 TYP. P1 P2 P2 H3 H3 H3 H7 H1 H3 A3 P1 P2P2 H4H8 H4H8 S1 H9 H9 H5 H5 S3 P3 P3 P3 P3P3 P3 P3 P3 P3 P3 P3 C200 SI T E P L A N w1 5 0 4 8 3 - C 2 0 0 s i t e SITE PLAN GENERAL NOTES 1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, OR VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM THE RESPECTIVE CITY, COUNTY, AND STATE AGENCIES PRIOR TO STARTING CONSTRUCTION. 2.ALL QUANTITIES GIVEN ON THESE PRINTS, VERBALLY OR IN THE SCOPE OF WORK SECTION ARE ESTIMATES AND SHALL BE CONFIRMED BY THE BIDDING CONTRACTORS. 3.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29 CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. IN ADDITION, EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER. 4.IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER AND CONTRACTOR TO MAINTAIN QUALITY CONTROL THROUGHOUT THIS PROJECT. 5.TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL STANDARDS. 6.BEARINGS, DIMENSIONS, AND EASEMENTS ARE SHOWN FOR REFERENCE ONLY. SEE RECORD SURVEYS AND PLATS FOR EXACT INFORMATION. 7.THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODS ASSOCIATED WITH THE PROJECT. 8.ALL DIMENSIONS ARE BASED ON FACE OF CURB OR BACK OF ROLL CURB OR FACE OF BUILDING. 9.SEE ARCHITECTURAL PLANS FOR DETAILS OF BUILDING, BUILDING DIMENSIONS, ATM RELATED DETAILS, AND SIGNAGE SPECIFICATIONS. DO NOT STAKE BUILDING FROM THESE PLANS. 10.COORDINATE CONSTRUCTION ACTIVITIES WITH ADJOINING WORK IF APPLICABLE. VERIFY EXTENT OF ADJOINING WORK AND COORDINATE AS REQUIRED. 11.FIELD VERIFY EXISTING CURBS AND TAPER PROPOSED VERTICAL CURBS TO MATCH WITHIN A MIN. OF THREE (3) FEET. 12.± DIMENSIONS INDICATE FIELD DIMENSION ADJUSTMENT AREA BASED ON ACTUAL FIELD LAYOUT COORDINATES. 13.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO START OF CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS. IF ANY DISCREPANCIES ARE FOUND IN THESE PLANS FROM ACTUAL FIELD CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 14.PROVIDE SMOOTH TRANSITION FROM NEWLY PAVED AREAS TO EXISTING AREAS AS NECESSARY. ALL AREAS WHERE PROPOSED PAVEMENT MEETS EXISTING PAVEMENT, THE EXISTING EDGE OF PAVEMENT SHALL BE FREE OF ALL LOOSE DEBRIS. THE EDGE OF EXISTING ASPHALT PAVEMENT SHALL BE PROPERLY SEALED WITH A TACK COAT MATERIAL IN ALL AREAS WHERE NEW ASPHALT PAVEMENT IS INDICATED TO JOIN EXISTING. 15.RESURFACE OR RECONSTRUCT AT LEAST TO ORIGINAL CONDITIONS ALL AREAS WHERE THE EXISTING PAVEMENT OR LAWNS ARE DAMAGED DURING CONSTRUCTION FROM TRAFFIC BY CONTRACTORS, SUBCONTRACTORS, OR SUPPLIERS AFTER CONSTRUCTION WORK IS COMPLETE. 16.THE CONTRACTOR SHALL PROTECT AND NOT DESTROY THE PROPERTY CORNER MONUMENTS DURING CONSTRUCTION. 17.REFER TO ARCHITECTURAL PLANS FOR BUILDING ACCESSORY DETAILS. 18.REFER TO SHEET C201 FOR SITE PLAN DETAILS UNLESS OTHERWISE NOTED. 19.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS. STAFF NOTIFICATION REQUIREMENT, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF WORK, AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. SITE PLAN NOTES PAVEMENT REGULAR DUTY ASPHALT PAVING. SEE SHEET C201. MATCH EXISTING PAVEMENT EXISTING PAVEMENT TO BE EVALUATED FOR REPAIR OF RESURFACING AFTER GRADING, POND EXCAVATION, AND UTILITY INSTALLATION ARE COMPLETE. HEAVY DUTY PAVING. SEE SHEET C201. HARDSCAPE 6" CONCRETE CURB AND GUTTER. SEE SHEET C201. CONCRETE PARKING BARRIER. SEE SHEET C201. CONCRETE SIDEWALK. MATCH EXISTING SIDEWALK PAVEMENT FLUSH WITH SIDEWALK CURB TAPER. 3:1 TAPER 3' LEVEL SPREADER CONCRETE COLLAR ADA RAMP WITH INDICATORS TRUNCATED CURB, REFER TO DETAIL ON SHEET C201 ACCESSORIES EXISTING LIGHT POLE BASE-NEW FIXTURES PROPOSED LIGHT POLE BASE. COORDINATE WITH OWNER ON EXACT LOCATIONS. BIKE PARKING SIGNAGE & MARKINGS EXISTING ADA PARKING SPACES 4" PAINTED WHITE SOLID LINES (TYP) PEDESTRIAN CROSSWALK H1 H2 H3 H4 A1 A2 S1 S2 P1 P2 RE V I S I O N S A N D I S S U E S Pa r t o f t h e S E / 4 o f S e c t i o n 2 3 , T o w n s h i p 1 8 N o r t h , R a n g e 3 E a s t , C l a y T o w n s h i p , H a m i l t o n C o u n t y , I n d i a n a W15.0483 PR E P A R E D F O R : 12 4 2 W E S T 1 3 6 T H S T R E E T , C A R M E L , I N 4 6 0 3 2 PROJECT NO. SHEET NO. CH E C K E D B Y : DR A W N B Y : RL W DE S I G N E D B Y : DW G N A M E : PR O J E C T N O . : W1 5 . 0 4 8 3 DA T E BY 05 . 1 9 . 2 0 1 6 SS R DA T E : RL W EN G I N E E R S 31 7 | 8 4 6 - 6 6 1 1 80 0 | 4 5 2 - 6 4 0 8 31 7 | 8 4 3 - 0 5 4 6 fa x W E I H E La n d S u r v e y i n g | C i v i l E n g i n e e r i n g La n d s c a p e A r c h i t e c t u r e AL L A N H . W E I H E , P . E . , L . S . - F O U N D E R 10 5 0 5 N . C o l l e g e A v e n u e In d i a n a p o l i s , I n d i a n a 4 6 2 8 0 we i h e . n e t Know what's below. before you dig.Call R TR A D E R ' S P O I N T C H U R C H O F C A R M E L SU B M I T T E D F O R I N I T I A L R E V I E W 12 . 1 8 . 2 0 1 5 ML T W S N E THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD AREA AS ESTABLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY SCALE ON FLOOD INSURANCE RATE #18057C207G, DATED NOVEMBER 19, 2014 FLOOD STATEMENT STEVEN SCOTT RUCKER P.E. 11300279 SU B M I T T E D F O R T A C R E V I S I O N S 03 . 1 4 . 2 0 1 6 ML T NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT NOTE SU B M I T T E D F O R D R A I N A G E A P P R O V A L 04 . 2 0 . 2 0 1 6 ML T RE V I S E D F O R D R A I N A G E A P P R O V A L 05 . 1 2 . 2 0 1 6 ML T FI N A L C O N S T R U C T I O N P L A N S 05 . 1 9 . 2 0 1 6 ML T ELECTRICAL RISER GUY ANCHOR ELECTRIC JUNCTION BOX STREET LIGHT UTILITY POLE TRANSFORMER COMMUNICATIONS JUNCTION BOX COMMUNICATIONS MANHOLE COMMUNICATIONS PEDESTAL RIGHT OF WAY LINE FENCE BUILDING SETBACK LINE BOUNDARY LINE FIRE DEPT HOOKUP FIRE HYDRANT POST INDICATOR VALVE CHILLED WATER MANHOLE WATER MANHOLE WATER METER WATER VALVE GAS METER GAS VALVE ELECTRIC METER BOLLARD POST SIGN PARKING WHEEL STOP DOWN SPOUT HANDICAPPED SPACE COMMUNICATIONS RISER CURB INLET ROUND INLET SQUARE INLET STORM MANHOLE SANITARY SEWER CLEANOUT SANITARY SEWER MANHOLE PARKING LOT LIGHT (1 HEAD) PARKING LOT LIGHT (2 HEAD) ASPHALT PAVING CONCRETE PAVEMENT ROW RIGHT OF WAY BSL BUILDING SETBACK LINE ESMT EASEMENT D.&U.E.DRAINAGE AND UTILITY EASEMENT FFE FINISH FLOOR ELEVATION 12 PARKING COUNT PAVEMENT SITE PLAN LEGEND UTILITIES ABBREVIATIONSOTHER LINE TYPES SECTION LINE SITE DATA SITE AREA = 5.66 TOTAL ACRES ZONING = S-2 FRONT YARD BUFFER REQUIRED = 15 FT REAR AND SIDE BUFFER = 25 FT PARKING REQUIRED: PARKING REQUIREMENT = 1 SPACE PER 4 SEATS PARKING REQUIRED = 125 SPACES PARKING DIMENSIONS = 9' X 18' PARKING PROVIDED: 86 - NEW SPACES 153 - EXISTING SPACES 11 - EXISTING ADA SPACES 250 - TOTAL SPACES H5 H6 H7 A3 H8 H9 S3 P3 P4