Loading...
HomeMy WebLinkAboutC301 STORM SEWER DETAILSCENTER 860 865 870 875 880 860 865 870 875 880 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 PARKING AREA 100 YR. ELEV.=869.73 SIDE SLOPE=3:1 TYP. SIDE SLOPE=3:1 TYP. LEVEL SPREADER TRENCH WITH SSD B B SECTION A-A SECTION B-B A 48" SPECIAL STRUCTURE #101 48" 4 8 " B SECTION A-A SECTION B-B TYPE 'A' STRUCTURE #104 A B A 2.00 2.00 2.00 2. 0 0 1' S U M P S T M S T M S T M S T M S T M S T M S T M S T M S T M S T M ST M SSD WITHIN TRENCH SECTION A-A CONC. PIPE TOE ANCHOR 12" C TO C MAX. SPACING E+2T GROOVED ON OUTLET END, TONGUE END ON INLET END. GROOVE (OR TONGUE) TO BE THE SAME AS ON STANDARD REINFORCED CONCRETE PIPE, ASTM DESIGNATION C-76. CLASS "A" CONCRETE3" 6" NOTE: METAL PIPE END SECTIONS MAY BE USED WITH CONCRETE PIPE, PROVIDING THE METHOD OF CONNECTION IS APPROVED BY THE ENGINEER PRIOR TO INSTALLATION OF PIPE. (EXCEPT IN INDIANAPOLIS) 12 " C . T O C . MA X . S P A . CL 9" 6" DIA. CONCRETE IN THESE END SECTIONS SHALL BE THE SAME GRADE AND STRENGTH AS SPECIFIED FOR REINFORCED CONCRETE PIPE, A.S.T.M. DESIGNATION C-76 CLASS II, (AS SET OUT IN INDOT STANDARD SPECIFICATIONS). REINFORCEMENT IN THE "C" PORTION SHALL BE THE SAME AS SPECIFIED FOR REINFORCED CONCRETE, A.S.T.M. DESIGNATION C-76 CLASS II, FOR THE SIZE OF CONNECTING PIPE. REINFORCEMENT IN THE "B" PORTION SHALL HAVE A CROSS SECTIONAL AREA EQUAL TO THAT OF ONE LAYER OF STEEL IN THE "C" PORTION. THE END OF THE PIPE CULVERT SHALL BE PLACED IN THE CONCRETE END SECTION SO THAT THE FLOW LINES ARE FLUSH. THE JOINT SHALL BE COMPLETELY FILLED WITH MORTAR. IN 3:1 OR 4:1 FILL SLOPE, CHANGE TO THE SLOPE OF THE END SECTION IN A SMOOTH, PLEASING TRANSITION APPROXIMATELY 10'-0" IN LENGTH. VARIATIONS IN DIMENSIONS - THE THICKNESS OF THE CONCRETE, THE POSITION OF STEEL, AND THE INTERNAL DIAMETER OF THE PIPE SHALL CONFORM WITH THE VARIATIONS IN DIMENSIONS AS PROVIDED IN THE SPECIFICATIONS FOR REINFORCED CONCRETE CULVERT, STORM DRAIN, AND SEWER PIPE, A.S.T.M. DESIGNATION C-??? WHERE VITRIFIED CLAY CULVERT OR CAST IRON CULVERT PIPE IS USED, A "PIPE END SECTION" COMPARABLE TO THAT AS SHOWN FOR METAL OR CONCRETE SHALL BE FURNISHED AND SHALL BE AS APPROVED BY THE ENGINEER, EXCEPT IN AREAS OF ACID OR MINE WATER THEN THE USE OF METAL END SECTION IS PROHIBITED. END SECTIONS WILL BE PAID FOR AT THE CONTRACT UNIT PRICE EACH FOR "PIPE END SECTION" COMPLETE. CONCRETE PIPE TOE ANCHORS SHALL BE REQUIRED ON ALL CONCRETE PIPE END SECTIONS. THE COST THEREOF SHALL BE INCLUDED IN THE CONTRACT UNIT PRICE PER EACH FOR "PIPE END SECTION." RIP-RAP TO BE PLACED ON SIDE SLOPE WHEN CALLED FOR ON PLANS. END SECTION LENGTH (D)PAY LENGTH OF CULVERT COMPUTED LENGTH OF CULVERT CONCRETE END SECTION PIPE CULVERT HOOK BOLTS LONGITUDINAL SECTION C301 ST O R M S E W E R D E T A I L S w1 5 0 4 8 3 - C 3 0 2 d r a i n a g e d e t (NO SCALE) 1 1/2"R.1 1/2"R. T T Y Y T T 4:1 FILL S L O P E 3:1 F I L L S L O P E CLASS "A" CONC. 2' - 0 " T ADI A - 1 ' T DI A - 1 ' T C B=(D-C) D C SLOPE DETAIL PLAN VIEW SECTION Y-Y PRECAST CONCRETE END SECTION DETAIL 2' - 0 " R2 DI A . R 1 REQUIREMENTS FOR ALL STORM SEWER BENCHWALLS BENCH WALLS SHALL BE SHAPED AND FORMED FOR A CLEAN TRANSITION WITH PROPER HYDRAULICS TO ALLOW THE SMOOTH CONVEYANCE OF FLOWS THROUGH THE MANHOLE OR BOX INLET. THE BENCH WALL SHALL FORM A DEFINED CHANNEL, TO A MINIMUM HEIGHT OF 80-PERCENT OF THE INSIDE DIAMETER OF THE INLET AND OUTLET PIPES TO FORM A "U" SHAPED CHANNEL, CONSTRUCTED AT A MINIMUM ½-INCH PER FOOT SLOPE TO THE MANHOLE WALL. WHERE A FLOW CHANNEL IS CONSTRUCTED AS AN INTEGRAL PART OF THE PRE-CAST BASE, IT SHALL BE SHAPED AND FORMED AS DESCRIBED ABOVE, WITH THE EXCEPTION THAT THE BOTTOM OF THE FLOW CHANNEL MAY BE FORMED FROM THE BOTTOM OF INLET AND OUTLET PIPES IF THE PIPE WALL THICKNESS IS NOT GREATER THAN ONE (1) INCH. FOR CAST-IN-PLACE FLOW CHANNELS, THE BOTTOM INVERT OF ALL PIPES ENTERING A MANHOLE SHALL BE AT LEAST THREE (3) INCHES ABOVE THE TOP OF THE BASE SLAB TO THE OUTLET INVERT SO THE FINISHED SEWER CHANNEL MAY BE INSTALLED AND SHAPED. FOR CONNECTIONS TO EXISTING STORM SEWER STRUCTURES, FLOW CHANNELS SHALL BE SHAPED, AS SPECIFIED HEREIN, AS IF IT WERE A NEW MANHOLE OR BOX INLET STRUCTURE. SPECIFICATIONS FOR ALL STORM SEWER CASTINGS ALL STORM WATER INLETS AND CATCH BASINS SHALL HAVE THE WORDS "NO DUMPING, DRAINS TO STREAM", OR SIMILARLY APPROVED MESSAGE, CAST IN RAISED OR RECESSED LETTERS AT A MINIMUM OF 1" IN HEIGHT. IN ADDITION, A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS. 1/6 Bc (NO SCALE) Bc d d(MIN.) 66" & LARGER 30" TO 60" 27" & SMALLER D 6 4 3 GREATER THAN 5' (1) LESS THAN 5' (2) B = OUTSIDE DIAMETER D = INSIDE DIAMETER d = DEPTH OF BEDDING MATERIAL BELOW PIPE TYPICAL BEDDING SECTION - RCP PIPE MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT. (1) MIN. 1.25 Bc (2) 1.25 Bc + 12" (MIN.) EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE. (1) REGULAR BACKFILL (2) "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY. "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY. NOTE: ALL BEDDING & INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS. A MIN. OF 9" CLEARANCE SHALL BE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE. (2) "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY #8 CRUSHED STONE OR APPROVED EQUIV. CLASS I BEDDING MATERIAL HAND TAMPED OR WALKED INTO PLACE TYPICAL BEDDING SECTION - PVC & HDPE (NO SCALE) 4" ALL BEDDING & INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS A MIN. 9" CLEARANCE SHALL BE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE. Bc = OUTSIDE DIAMETER D = INSIDE DIAMETER D = DEPTH OF BEDDING MATERIAL BELOW PIPE (1) REGULAR BACKFILL GREATER THAN 5' (1) EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC RIGHT-OF-WAY LESS THAN 5' (2) 1.25 Bc + 12" (MIN.) MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT 12 " M I N . Bc 869.80870.0 870.0 NOTE: THE EMERGENCY OVERFLOW SHOULD HAVE A MINIMUM 1' OF FREEBOARD ABOVE THE MAXIMUM ANTICIPATED FLOW THROUGH THE EMERGENCY OVERFLOW. 18" DEEP RIPRAP (1/3 CU. FT. MIN. SIZE) 3:1 S L O P E EMERGENCY OVERFLOW 100 YEAR ELEV.=869.79 3:1 SLO P E NORTH POND EMERGENCY SPILLWAY (NO SCALE) RE V I S I O N S A N D I S S U E S Pa r t o f t h e S E / 4 o f S e c t i o n 2 3 , T o w n s h i p 1 8 N o r t h , R a n g e 3 E a s t , C l a y T o w n s h i p , H a m i l t o n C o u n t y , I n d i a n a W15.0483 PR E P A R E D F O R : 12 4 2 W E S T 1 3 6 T H S T R E E T , C A R M E L , I N 4 6 0 3 2 PROJECT NO. SHEET NO. CH E C K E D B Y : DR A W N B Y : RL W DE S I G N E D B Y : DW G N A M E : PR O J E C T N O . : W1 5 . 0 4 8 3 DA T E BY 05 . 1 9 . 2 0 1 6 SS R DA T E : RL W EN G I N E E R S 31 7 | 8 4 6 - 6 6 1 1 80 0 | 4 5 2 - 6 4 0 8 31 7 | 8 4 3 - 0 5 4 6 fa x W E I H E La n d S u r v e y i n g | C i v i l E n g i n e e r i n g La n d s c a p e A r c h i t e c t u r e AL L A N H . W E I H E , P . E . , L . S . - F O U N D E R 10 5 0 5 N . C o l l e g e A v e n u e In d i a n a p o l i s , I n d i a n a 4 6 2 8 0 we i h e . n e t Know what's below. before you dig.Call R TR A D E R ' S P O I N T C H U R C H O F C A R M E L SU B M I T T E D F O R I N I T I A L R E V I E W 12 . 1 8 . 2 0 1 5 ML T THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD AREA AS ESTABLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY SCALE ON FLOOD INSURANCE RATE #18057C207G, DATED NOVEMBER 19, 2014 FLOOD STATEMENT STEVEN SCOTT RUCKER P.E. 11300279 SU B M I T T E D F O R T A C R E V I S I O N S 03 . 1 4 . 2 0 1 6 ML T NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT NOTE SU B M I T T E D F O R D R A I N A G E A P P R O V A L 04 . 2 0 . 2 0 1 6 ML T RE V I S E D F O R D R A I N A G E A P P R O V A L 05 . 1 2 . 2 0 1 6 ML T FI N A L C O N S T R U C T I O N P L A N S 05 . 1 9 . 2 0 1 6 ML T MANHOLE (DIA. "F") PIPES ENTERING/ LEAVING AT 0-45 DEGREES FINISH GRADE OR PAVEMENT MANHOLE (DIA. "F") PIPES ENTERING/ LEAVING AT 45-90 DEGREES PIPE SIZE (DIA. "G") CASTING FRAME & COVER AS SPECIFIED ASPHALTIC MASTIC OR BUTYL RUBBER SEAL BETWEEN JOINTS. STANDARD PRECAST MANHOLE CAP OR ECCENTRIC CONE. (UP TO 24" PIPE.) FULL HEIGHT MANHOLE STEPS AS REQUIRED. CONCRETE REDUCER CAP PRECAST CONC. ADJUSTER RINGS, IF NEEDED (12 MAX.) BENCHWALLS AT MINIMUM 1 2" PERFOOT SLOPE. BENCHWALLS TO BE CONSTRUCTED TO SPRINGLINE OF PIPE. INVERT ELEVATION BASE SHALL BE POURED IN PLACE OR PRECAST. BOTH SHALL HAVE #4 BARS-12" O.C. BOTH WAYS. BASE SET ON 6" OF #8 OR #2 STONE DIAMETER "G" DIAMETER "F" 4'-0" DIA. 24" DIA. 24 " D I A . PREFORMED HOLE TO MAX OF PIPE O.D. + 6" WITH NON-SHRINK CEMENT GROUT NOTE MANHOLE STEPS SHALL BE POLYPROPYLENE, POLYPROPYLENE COATED STEEL REINFORCING OR AN APPROVED NON-CORROSIVE FIBERGLASS MATERIAL. THE COPOLYMER POLYPROPYLENE SHALL MEET THE REQUIREMENTS OF ASTM D-4101 REINFORCED WITH DEFORMED 3 8" MIN. DIAMETER REINFORCED STEEL CONFORMING TO THE REQUIREMENTS OF ASTM A-615, GRADE 60. NON-COATED CAST IRON STEPS ARE NOT ACCEPTABLE. UP TO 60 DEGREES 16" (TYP.) 5" 6" NOTE ·MANHOLE CONFORMS TO ASTM C-478 ·NO BRICK OR BLOCK WILL BE ALLOWED IN MANHOLE ·O-RING GASKET ASPHALTIC MASTIC OR BUTYL RUBBER SEAL BETWEEN MANHOLE JOINTS 3"MIN. 3"MIN. 6" for 48" Dia 8" for > 48" Dia (NO SCALE) STANDARD STORM MANHOLE 12"-21" 24" 27"-30" 33"-36" 42" 48" 54" 60" 66"N/A N/A N/A 84" 72" 60" 60" 48" 48"48" 60" 60" 72" 84" 96" N/A N/A N/A 96" 96" 96" N/A N/A N/A N/A N/A N/A NORTH CROSS-SECTION FOR DRY DETENTION, INFILTRATION TRENCH, AND LEVEL SPREADERS. LEVEL LIP OF SPREADER EXISTING SUBSOIL 3' MIN (NO SCALE)LEVEL SPREADER - CROSS SECTION PAVEMENT 1.5' MIN SL O P E T O D E T E N T I O N 1' SOD LINE SIDES AND BOTTOM OF TRENCH WITH NON-WOVEN FILTER FABRIC. FILTER STRIP BOTTOM OF EMERGENCY SPILLWAY 6" PERFORATED, DUAL-WALLED SUB-SURFACE HDPE DRAIN UN-COMPACTED, WASHED 2" STONE WITH NO FINES APPROXIMATE LOCATION. REFER TO PLANS. FILTER FABRIC