HomeMy WebLinkAboutC301 STORM SEWER DETAILSCENTER
860
865
870
875
880
860
865
870
875
880
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00
PARKING AREA
100 YR. ELEV.=869.73
SIDE SLOPE=3:1 TYP.
SIDE SLOPE=3:1 TYP.
LEVEL SPREADER
TRENCH WITH SSD
B
B
SECTION A-A SECTION B-B
A
48"
SPECIAL STRUCTURE #101
48"
4
8
"
B
SECTION A-A SECTION B-B
TYPE 'A' STRUCTURE #104
A
B
A
2.00 2.00
2.00
2.
0
0
1'
S
U
M
P
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
S
T
M
ST
M
SSD WITHIN TRENCH
SECTION A-A
CONC. PIPE TOE ANCHOR
12" C TO C
MAX. SPACING
E+2T
GROOVED ON
OUTLET END,
TONGUE END
ON INLET
END.
GROOVE (OR TONGUE)
TO BE THE SAME AS ON
STANDARD
REINFORCED
CONCRETE PIPE, ASTM
DESIGNATION C-76.
CLASS "A"
CONCRETE3"
6"
NOTE:
METAL PIPE END
SECTIONS MAY BE USED
WITH CONCRETE PIPE,
PROVIDING THE METHOD
OF CONNECTION IS
APPROVED BY THE
ENGINEER PRIOR TO
INSTALLATION OF PIPE.
(EXCEPT IN INDIANAPOLIS)
12
"
C
.
T
O
C
.
MA
X
.
S
P
A
.
CL
9"
6"
DIA.
CONCRETE IN THESE END SECTIONS SHALL BE THE SAME GRADE AND STRENGTH AS SPECIFIED FOR REINFORCED CONCRETE PIPE,
A.S.T.M. DESIGNATION C-76 CLASS II, (AS SET OUT IN INDOT STANDARD SPECIFICATIONS).
REINFORCEMENT IN THE "C" PORTION SHALL BE THE SAME AS SPECIFIED FOR REINFORCED CONCRETE, A.S.T.M. DESIGNATION C-76
CLASS II, FOR THE SIZE OF CONNECTING PIPE.
REINFORCEMENT IN THE "B" PORTION SHALL HAVE A CROSS SECTIONAL AREA EQUAL TO THAT OF ONE LAYER OF STEEL IN THE "C"
PORTION.
THE END OF THE PIPE CULVERT SHALL BE PLACED IN THE CONCRETE END SECTION SO THAT THE FLOW LINES ARE FLUSH. THE
JOINT SHALL BE COMPLETELY FILLED WITH MORTAR.
IN 3:1 OR 4:1 FILL SLOPE, CHANGE TO THE SLOPE OF THE END SECTION IN A SMOOTH, PLEASING TRANSITION APPROXIMATELY 10'-0"
IN LENGTH.
VARIATIONS IN DIMENSIONS - THE THICKNESS OF THE CONCRETE, THE POSITION OF STEEL, AND THE INTERNAL DIAMETER OF THE
PIPE SHALL CONFORM WITH THE VARIATIONS IN DIMENSIONS AS PROVIDED IN THE SPECIFICATIONS FOR REINFORCED CONCRETE
CULVERT, STORM DRAIN, AND SEWER PIPE, A.S.T.M. DESIGNATION C-???
WHERE VITRIFIED CLAY CULVERT OR CAST IRON CULVERT PIPE IS USED, A "PIPE END SECTION" COMPARABLE TO THAT AS SHOWN
FOR METAL OR CONCRETE SHALL BE FURNISHED AND SHALL BE AS APPROVED BY THE ENGINEER, EXCEPT IN AREAS OF ACID OR
MINE WATER THEN THE USE OF METAL END SECTION IS PROHIBITED.
END SECTIONS WILL BE PAID FOR AT THE CONTRACT UNIT PRICE EACH FOR "PIPE END SECTION" COMPLETE.
CONCRETE PIPE TOE ANCHORS SHALL BE REQUIRED ON ALL CONCRETE PIPE END SECTIONS. THE COST THEREOF SHALL BE
INCLUDED IN THE CONTRACT UNIT PRICE PER EACH FOR "PIPE END SECTION."
RIP-RAP TO BE
PLACED ON SIDE
SLOPE WHEN
CALLED FOR ON
PLANS.
END SECTION
LENGTH (D)PAY LENGTH
OF CULVERT
COMPUTED LENGTH
OF CULVERT
CONCRETE
END SECTION
PIPE CULVERT
HOOK
BOLTS
LONGITUDINAL
SECTION
C301
ST
O
R
M
S
E
W
E
R
D
E
T
A
I
L
S
w1
5
0
4
8
3
-
C
3
0
2
d
r
a
i
n
a
g
e
d
e
t
(NO SCALE)
1 1/2"R.1 1/2"R.
T
T
Y
Y
T
T
4:1 FILL S
L
O
P
E
3:1
F
I
L
L
S
L
O
P
E
CLASS "A" CONC.
2'
-
0
"
T
ADI
A
-
1
'
T
DI
A
-
1
'
T
C B=(D-C)
D
C
SLOPE DETAIL
PLAN VIEW SECTION Y-Y
PRECAST CONCRETE END SECTION DETAIL
2'
-
0
"
R2
DI
A
.
R
1
REQUIREMENTS FOR ALL STORM SEWER BENCHWALLS
BENCH WALLS SHALL BE SHAPED AND FORMED FOR A CLEAN TRANSITION WITH PROPER
HYDRAULICS TO ALLOW THE SMOOTH CONVEYANCE OF FLOWS THROUGH THE MANHOLE OR BOX
INLET. THE BENCH WALL SHALL FORM A DEFINED CHANNEL, TO A MINIMUM HEIGHT OF 80-PERCENT
OF THE INSIDE DIAMETER OF THE INLET AND OUTLET PIPES TO FORM A "U" SHAPED CHANNEL,
CONSTRUCTED AT A MINIMUM ½-INCH PER FOOT SLOPE TO THE MANHOLE WALL.
WHERE A FLOW CHANNEL IS CONSTRUCTED AS AN INTEGRAL PART OF THE PRE-CAST BASE, IT
SHALL BE SHAPED AND FORMED AS DESCRIBED ABOVE, WITH THE EXCEPTION THAT THE BOTTOM
OF THE FLOW CHANNEL MAY BE FORMED FROM THE BOTTOM OF INLET AND OUTLET PIPES IF THE
PIPE WALL THICKNESS IS NOT GREATER THAN ONE (1) INCH.
FOR CAST-IN-PLACE FLOW CHANNELS, THE BOTTOM INVERT OF ALL PIPES ENTERING A MANHOLE
SHALL BE AT LEAST THREE (3) INCHES ABOVE THE TOP OF THE BASE SLAB TO THE OUTLET INVERT
SO THE FINISHED SEWER CHANNEL MAY BE INSTALLED AND SHAPED.
FOR CONNECTIONS TO EXISTING STORM SEWER STRUCTURES, FLOW CHANNELS SHALL BE SHAPED,
AS SPECIFIED HEREIN, AS IF IT WERE A NEW MANHOLE OR BOX INLET STRUCTURE.
SPECIFICATIONS FOR ALL STORM SEWER CASTINGS
ALL STORM WATER INLETS AND CATCH BASINS SHALL HAVE THE WORDS "NO DUMPING, DRAINS TO
STREAM", OR SIMILARLY APPROVED MESSAGE, CAST IN RAISED OR RECESSED LETTERS AT A
MINIMUM OF 1" IN HEIGHT. IN ADDITION, A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE
LETTERS.
1/6 Bc
(NO SCALE)
Bc
d d(MIN.)
66" & LARGER
30" TO 60"
27" & SMALLER
D
6
4
3
GREATER THAN 5' (1)
LESS THAN 5' (2)
B = OUTSIDE DIAMETER
D = INSIDE DIAMETER
d = DEPTH OF BEDDING
MATERIAL BELOW PIPE
TYPICAL BEDDING SECTION - RCP PIPE
MIN. 6" TOPSOIL TO
ENSURE GRASS
GROWTH IF NOT
UNDER PAVEMENT.
(1) MIN. 1.25 Bc
(2) 1.25 Bc + 12" (MIN.)
EDGE OF
PAVEMENT, CURB,
GUTTER OR
SIMILAR
STRUCTURE.
(1) REGULAR
BACKFILL
(2) "B" BORROW OR
EQUIV. GRANULAR
MATERIAL COMPACTED
TO 95% STANDARD
PROCTOR DENSITY.
"B" BORROW OR EQUIV.
GRANULAR MATERIAL
COMPACTED TO 95% STANDARD
PROCTOR DENSITY.
NOTE:
ALL BEDDING & INITIAL BACKFILL
SHALL BE INSTALLED IN 6" TO
12" BALANCED LIFTS. A MIN. OF
9" CLEARANCE SHALL BE
PROVIDED ON EACH SIDE OF
THE INSTALLED PIPE.
(2) "B" BORROW OR
EQUIV. GRANULAR
MATERIAL COMPACTED
TO 95% STANDARD
PROCTOR DENSITY
#8 CRUSHED STONE OR
APPROVED EQUIV. CLASS I
BEDDING MATERIAL HAND
TAMPED OR WALKED INTO
PLACE
TYPICAL BEDDING SECTION - PVC & HDPE
(NO SCALE)
4"
ALL BEDDING & INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS
A MIN. 9" CLEARANCE SHALL BE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE.
Bc = OUTSIDE DIAMETER
D = INSIDE DIAMETER
D = DEPTH OF BEDDING
MATERIAL BELOW PIPE
(1) REGULAR BACKFILL
GREATER THAN 5' (1)
EDGE OF PAVEMENT,
CURB, GUTTER OR
SIMILAR STRUCTURE
IN THE PUBLIC
RIGHT-OF-WAY
LESS THAN 5' (2)
1.25 Bc + 12" (MIN.)
MIN. 6" TOPSOIL
TO ENSURE GRASS
GROWTH IF NOT
UNDER PAVEMENT
12
"
M
I
N
.
Bc
869.80870.0 870.0
NOTE: THE EMERGENCY OVERFLOW SHOULD
HAVE A MINIMUM 1' OF FREEBOARD ABOVE
THE MAXIMUM ANTICIPATED FLOW THROUGH
THE EMERGENCY OVERFLOW.
18" DEEP RIPRAP (1/3 CU.
FT. MIN. SIZE)
3:1 S
L
O
P
E
EMERGENCY OVERFLOW
100 YEAR
ELEV.=869.79
3:1 SLO
P
E
NORTH POND
EMERGENCY SPILLWAY
(NO SCALE)
RE
V
I
S
I
O
N
S
A
N
D
I
S
S
U
E
S
Pa
r
t
o
f
t
h
e
S
E
/
4
o
f
S
e
c
t
i
o
n
2
3
,
T
o
w
n
s
h
i
p
1
8
N
o
r
t
h
,
R
a
n
g
e
3
E
a
s
t
,
C
l
a
y
T
o
w
n
s
h
i
p
,
H
a
m
i
l
t
o
n
C
o
u
n
t
y
,
I
n
d
i
a
n
a
W15.0483
PR
E
P
A
R
E
D
F
O
R
:
12
4
2
W
E
S
T
1
3
6
T
H
S
T
R
E
E
T
,
C
A
R
M
E
L
,
I
N
4
6
0
3
2
PROJECT NO.
SHEET NO.
CH
E
C
K
E
D
B
Y
:
DR
A
W
N
B
Y
:
RL
W
DE
S
I
G
N
E
D
B
Y
:
DW
G
N
A
M
E
:
PR
O
J
E
C
T
N
O
.
:
W1
5
.
0
4
8
3
DA
T
E
BY
05
.
1
9
.
2
0
1
6
SS
R
DA
T
E
:
RL
W
EN
G
I
N
E
E
R
S
31
7
|
8
4
6
-
6
6
1
1
80
0
|
4
5
2
-
6
4
0
8
31
7
|
8
4
3
-
0
5
4
6
fa
x
W E I H E
La
n
d
S
u
r
v
e
y
i
n
g
|
C
i
v
i
l
E
n
g
i
n
e
e
r
i
n
g
La
n
d
s
c
a
p
e
A
r
c
h
i
t
e
c
t
u
r
e
AL
L
A
N
H
.
W
E
I
H
E
,
P
.
E
.
,
L
.
S
.
-
F
O
U
N
D
E
R
10
5
0
5
N
.
C
o
l
l
e
g
e
A
v
e
n
u
e
In
d
i
a
n
a
p
o
l
i
s
,
I
n
d
i
a
n
a
4
6
2
8
0
we
i
h
e
.
n
e
t
Know what's below.
before you dig.Call
R
TR
A
D
E
R
'
S
P
O
I
N
T
C
H
U
R
C
H
O
F
C
A
R
M
E
L
SU
B
M
I
T
T
E
D
F
O
R
I
N
I
T
I
A
L
R
E
V
I
E
W
12
.
1
8
.
2
0
1
5
ML
T
THE SITE DOES NOT LIE IN A SPECIAL FLOOD
HAZARD AREA AS ESTABLISHED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY - NATIONAL
FLOOD INSURANCE PROGRAM, WHEN PLOTTED
BY SCALE ON FLOOD INSURANCE RATE
#18057C207G, DATED NOVEMBER 19, 2014
FLOOD STATEMENT
STEVEN SCOTT RUCKER P.E. 11300279
SU
B
M
I
T
T
E
D
F
O
R
T
A
C
R
E
V
I
S
I
O
N
S
03
.
1
4
.
2
0
1
6
ML
T
NO EARTH DISTURBING
ACTIVITY MAY TAKE
PLACE WITHOUT AN
APPROVED STORM
WATER MANAGEMENT
PERMIT
NOTE
SU
B
M
I
T
T
E
D
F
O
R
D
R
A
I
N
A
G
E
A
P
P
R
O
V
A
L
04
.
2
0
.
2
0
1
6
ML
T
RE
V
I
S
E
D
F
O
R
D
R
A
I
N
A
G
E
A
P
P
R
O
V
A
L
05
.
1
2
.
2
0
1
6
ML
T
FI
N
A
L
C
O
N
S
T
R
U
C
T
I
O
N
P
L
A
N
S
05
.
1
9
.
2
0
1
6
ML
T
MANHOLE (DIA. "F")
PIPES ENTERING/
LEAVING AT
0-45 DEGREES
FINISH GRADE OR PAVEMENT
MANHOLE (DIA. "F")
PIPES ENTERING/
LEAVING AT
45-90 DEGREES
PIPE SIZE
(DIA. "G")
CASTING FRAME & COVER AS SPECIFIED
ASPHALTIC MASTIC OR BUTYL
RUBBER SEAL BETWEEN JOINTS.
STANDARD PRECAST
MANHOLE CAP OR ECCENTRIC
CONE. (UP TO 24" PIPE.)
FULL HEIGHT MANHOLE
STEPS AS REQUIRED.
CONCRETE REDUCER CAP
PRECAST CONC.
ADJUSTER RINGS, IF
NEEDED (12 MAX.)
BENCHWALLS AT MINIMUM 1
2" PERFOOT
SLOPE. BENCHWALLS TO BE
CONSTRUCTED TO SPRINGLINE OF PIPE.
INVERT ELEVATION
BASE SHALL BE POURED IN
PLACE OR PRECAST. BOTH
SHALL HAVE #4 BARS-12"
O.C. BOTH WAYS.
BASE SET ON 6"
OF #8 OR #2
STONE
DIAMETER "G"
DIAMETER "F"
4'-0" DIA.
24" DIA.
24
"
D
I
A
.
PREFORMED HOLE TO
MAX OF PIPE O.D. + 6"
WITH NON-SHRINK
CEMENT GROUT
NOTE
MANHOLE STEPS SHALL BE POLYPROPYLENE, POLYPROPYLENE COATED STEEL
REINFORCING OR AN APPROVED NON-CORROSIVE FIBERGLASS MATERIAL. THE COPOLYMER
POLYPROPYLENE SHALL MEET THE REQUIREMENTS OF ASTM D-4101 REINFORCED WITH
DEFORMED 3
8" MIN. DIAMETER REINFORCED STEEL CONFORMING TO THE REQUIREMENTS OF
ASTM A-615, GRADE 60. NON-COATED CAST IRON STEPS ARE NOT ACCEPTABLE.
UP TO
60 DEGREES
16" (TYP.)
5"
6"
NOTE
·MANHOLE CONFORMS TO
ASTM C-478
·NO BRICK OR BLOCK WILL BE
ALLOWED IN MANHOLE
·O-RING GASKET ASPHALTIC
MASTIC OR BUTYL RUBBER
SEAL BETWEEN MANHOLE
JOINTS
3"MIN.
3"MIN.
6" for 48" Dia
8" for > 48" Dia
(NO SCALE)
STANDARD STORM MANHOLE
12"-21"
24"
27"-30"
33"-36"
42"
48"
54"
60"
66"N/A
N/A
N/A
84"
72"
60"
60"
48"
48"48"
60"
60"
72"
84"
96"
N/A
N/A
N/A 96"
96"
96"
N/A
N/A
N/A
N/A
N/A
N/A
NORTH CROSS-SECTION FOR DRY DETENTION,
INFILTRATION TRENCH, AND LEVEL SPREADERS.
LEVEL LIP OF SPREADER
EXISTING SUBSOIL
3' MIN
(NO SCALE)LEVEL SPREADER - CROSS SECTION
PAVEMENT
1.5' MIN
SL
O
P
E
T
O
D
E
T
E
N
T
I
O
N
1' SOD
LINE SIDES AND BOTTOM OF TRENCH
WITH NON-WOVEN FILTER FABRIC.
FILTER STRIP
BOTTOM OF EMERGENCY SPILLWAY
6" PERFORATED, DUAL-WALLED
SUB-SURFACE HDPE DRAIN
UN-COMPACTED,
WASHED 2" STONE
WITH NO FINES
APPROXIMATE
LOCATION. REFER
TO PLANS.
FILTER FABRIC