Loading...
HomeMy WebLinkAboutC302 STORM SEWER DETAILSSTM STR. WQ MECHANICAL WATER QUALITY UNIT DETAILSOUTH WEST 860 865 870 875 880 860 865 870 875 880 -0+50 0+00 0+50 1+00 1+50 PARKING AREA 100 YR. ELEV.=869.79 SIDE SLOPE=3:1 TYP. SIDE SLOPE=3:1 TYP. B SECTION A-A SECTION B-B TYPE 'A' STRUCTURE #102 A B A 2.00 2.00 2.00 2. 0 0 1' S U M P STRUCTURE #103 OUTLET CONTROL MECHANICAL WATER QUALITY UNIT DETAIL OFFLINE AQUA SWIRL AS-4 C302 ST O R M S E W E R D E T A I L S w1 5 0 4 8 3 - C 3 0 2 d r a i n a g e d e t RE V I S I O N S A N D I S S U E S Pa r t o f t h e S E / 4 o f S e c t i o n 2 3 , T o w n s h i p 1 8 N o r t h , R a n g e 3 E a s t , C l a y T o w n s h i p , H a m i l t o n C o u n t y , I n d i a n a W15.0483 PR E P A R E D F O R : 12 4 2 W E S T 1 3 6 T H S T R E E T , C A R M E L , I N 4 6 0 3 2 PROJECT NO. SHEET NO. CH E C K E D B Y : DR A W N B Y : RL W DE S I G N E D B Y : DW G N A M E : PR O J E C T N O . : W1 5 . 0 4 8 3 DA T E BY 05 . 1 9 . 2 0 1 6 SS R DA T E : RL W EN G I N E E R S 31 7 | 8 4 6 - 6 6 1 1 80 0 | 4 5 2 - 6 4 0 8 31 7 | 8 4 3 - 0 5 4 6 fa x W E I H E La n d S u r v e y i n g | C i v i l E n g i n e e r i n g La n d s c a p e A r c h i t e c t u r e AL L A N H . W E I H E , P . E . , L . S . - F O U N D E R 10 5 0 5 N . C o l l e g e A v e n u e In d i a n a p o l i s , I n d i a n a 4 6 2 8 0 we i h e . n e t Know what's below. before you dig.Call R TR A D E R ' S P O I N T C H U R C H O F C A R M E L SU B M I T T E D F O R I N I T I A L R E V I E W 12 . 1 8 . 2 0 1 5 ML T THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD AREA AS ESTABLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY - NATIONAL FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY SCALE ON FLOOD INSURANCE RATE #18057C207G, DATED NOVEMBER 19, 2014 FLOOD STATEMENT STEVEN SCOTT RUCKER P.E. 11300279 SU B M I T T E D F O R T A C R E V I S I O N S 03 . 1 4 . 2 0 1 6 ML T NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT NOTE SU B M I T T E D F O R D R A I N A G E A P P R O V A L 04 . 2 0 . 2 0 1 6 ML T RE V I S E D F O R D R A I N A G E A P P R O V A L 05 . 1 2 . 2 0 1 6 ML T FI N A L C O N S T R U C T I O N P L A N S 05 . 1 9 . 2 0 1 6 ML T ™ Phone (888) 344-9044 Fax (423) 826-2112 2705 Kanasita Drive, Chattanooga, TN 37343 STORMWATER TREATMENT SOLUTIONS www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-4 Horseshoe PCS Standard Detail AS-4 PCS STD 02/06/12 Scale: Drawn By: Document: Date: JCW 1:20 U.S. Patent No. 6524473 and other Patent Pending * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. ** Orientation may vary from 90°, 180°, or custom angles to meet site conditions. In l e t 66" [1676 mm] 12" [305 mm] PCS Max 66" [1676 mm] A Ø54" [Ø1372 mm] Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Vent Arched Baffle Octagonal Base Plate STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ Vent Arched Baffle Slide riser over top ring and bolt in 4 placesRiser 68" [1727 mm] 104" [2642 mm] Swirl Inlet Swirl Outlet Bedding Undisturbed Soil Backfill 6" [152 mm] 18" [457 mm] Section A-A Plan View Grade (Rim) 30" [762 mm] Rim elevations to match finished grade. PCS risers should NOT be field cut by Contractor. Manhole Frame and Cover by Manufacturer. (See Details)5" [127 mm] MH Frame VariesVaries Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) 4 1/2" [114 mm] 1/2" [13 mm] 1" [25 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 1" [25 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 48" [1219 mm] Min. 12" [305 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete8" [203 mm] Gravel Backfill Gravel Backfill 4 1/2" [114 mm]Cover Frame 1" [25 mm] Thick Expansion Joint Material30" [762 mm] Riser #4 [13 mm] Rebar @ 6" [152 mm] Each Way 14" [356 mm]1/2" [13 mm] 3,000 psi [20 MPa] (min) Concrete Manhole Frame & Cover Detail For Traffic Loading Areas NTS If traffic loading (H-20) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch [25 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Backfill (90% Proctor Density) 48" [1219 mm] Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System A 41" [1042 mm] Ou t l e t 12" [305 mm] PCS Max Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Note: As an alternative, 42-inch OD, H-20 rated precast concrete rings may be substituted. 14-inch thickness must be maintained. BEEHIVE INLET TYPE "E" (NO SCALE) CLASS "A" CONCRETE DI A . SECTION A-A INLET SET ON 6" BASE OF #8 STONE "DUMP NO WASTE-DRAINS TO WATERWAY" 8" TOP OF CASTING ELEVATION E.J. 6489 NEENAH R-4215-C OR EQUAL NOTES: 1. 6" CONCRETE PRECAST OR POURED IN PLACE. 2. REFER TO BEDDING DETAIL AS REQUIRED 3. VAR. PIPE SIZE 21" MAX STRAIGHT CONNECTIONS 15" MAX SKEW CORNER CONNECTIONS 4. MIN. 8" FLAT TOP WITH 24" ROUND OPENING 5. PIPE CONNECTION TO BE SEALED WITH NON-SHRINK GROUT. 6. STRAIGHT-OUT CONNECTIONS SHOULD NOT BE MADE TO EITHER PRECAST BOX OR INLET WALL TOUCHED BY A SKEW/CORNER CONNECTION UNLESS SUFFICIENT BOX INLET WALL AREA REMAINS ON EACH SIDE OF THE CONNECTING PIPE TO ENSURE STRUCTURAL INTEGRITY OF THE PRECAST BOX. 7. A MAXIMUM OF TWO (2) SKEW/CORNER CONNECTIONS WILL BE ALLOWED FOR EACH PRECAST BOX INLET. 8. REFER TO PRECAST CONCRETE ADJUSTING RING DETAIL AS REQUIRED 2 REBAR #5 3.5' EA. WALL ADJUSTING RING AS REQUIRED PAVED AREA INLET TYPE "E" (NO SCALE) "DUMP NO WASTE-DRAINS TO WATERWAY" SL O P E SLOPE SLOPE SL O P E 6" CONCRETE 3'-0"3'-0" 3' - 0 " 3' - 0 " 6" CL CL 6" 6" 6" TOP OF CASTING ELEVATION E.J. 5250 NEENAH R-3405 OR EQUAL PAVEMENT E.J. 5250 NEENAH R-3405 OR EQUAL CLASS "A" CONCRETE DI A . SECTION A-A INLET SET ON 6" BASE OF #8 STONE 8" NOTES: 1. 6" CONCRETE PRECAST OR POURED IN PLACE. 2. REFER TO BEDDING DETAIL AS REQUIRED 3. VAR. PIPE SIZE 21" MAX STRAIGHT CONNECTIONS 15" MAX SKEW CORNER CONNECTIONS 4. MIN. 8" FLAT TOP WITH 24" SQUARE OPENING 5. PIPE CONNECTION TO BE SEALED WITH NON-SHRINK GROUT. 6. STRAIGHT-OUT CONNECTIONS SHOULD NOT BE MADE TO EITHER PRECAST BOX OR INLET WALL TOUCHED BY A SKEW/CORNER CONNECTION UNLESS SUFFICIENT BOX INLET WALL AREA REMAINS ON EACH SIDE OF THE CONNECTING PIPE TO ENSURE STRUCTURAL INTEGRITY OF THE PRECAST BOX. 7. A MAXIMUM OF TWO (2) SKEW/CORNER CONNECTIONS WILL BE ALLOWED FOR EACH PRECAST BOX INLET. 8. REFER TO PRECAST CONCRETE ADJUSTING RING DETAIL AS REQUIRED 2 REBAR #5 3.5' EA. WALL ADJUSTING RING AS REQUIRED MIN. 4000 PSI WEST CROSS-SECTION FOR DRY DETENTION RIP RAP PROTECTED POND SECTION (NO SCALE) 866.05 FILTER FABRIC 3:1 S L O P E 3:1 SLO P E 12" DEEP RIPRAP (1/3 CU. FT. MIN. SIZE) COMPACTED SUBGRADE FILTER FABRIC 866.10 868.42 866.10 868.42 869.20870.0 870.0 NOTE: THE EMERGENCY OVERFLOW SHOULD HAVE A MINIMUM 1' OF FREEBOARD ABOVE THE MAXIMUM ANTICIPATED FLOW THROUGH THE EMERGENCY OVERFLOW.18" DEEP RIPRAP (1/3 CU. FT. MIN. SIZE) 3:1 S L O P E EMERGENCY OVERFLOW 100 YEAR ELEV.=869.14 3:1 SLO P E EAST POND EMERGENCY SPILLWAY (NO SCALE) FILTER FABRIC