Loading...
319219 11/30/17 CITY OF CARMEL, INDIANA VENDOR: 131135 ; ® ONE CIVIC SQUARE HOOSIER FIRE EQUIPMENT INC CHECK AMOUNT: $*****3,145.50* CARMEL, INDIANA 46032 4009 MONTDALE PARK DRIVE CHECK NUMBER: 319219 4 �rriN�. VALPARAISO IN 46383 CHECK DATE: 11/30/17 DEPARTMENT ACCOUNT PO NUMBER INVOICE NUMBER AMOUNT DESCRIPTION 1120 4351000 98400IN 3,145.50 AUTO REPAIR & MAINTEN VOUCHER NO. WARRANT NO. Prescribed by State Board of Accounts city Form No.Pot (Rev.1995) ALLOWED 20 ACCOUNTS PAYABLE VOUCHER Vendor# 131135 I HOOSIER FIRE EQUIPMENT INC N SUM OF$ CITY OF CARMEL 4009 MONTDALE PARK DRIVE An invoice or bill to be properly itemized must show:kind of service,where performed,dates service rendered,by whom,rates per day,number of hours,rate per hour,number of units,price per unit,etc. VALPARAISO, IN 46383 Payee $3,145.50 Purchase Order# ON ACCOUNT OF APPROPRIATION FOR Carmel Fire Terms Date Due PO# ACCT# DATE INVOICE# DESCRIPTION DEPT# INVOICE# Fund# AMOUNT Board Members DEPT# FUND# (or note attached invoice(s)or bill(s)) AMOUNT 98400-IN 43-510.00 $3,145.50 1 hereby certify that the attached invoice(s),or 11/28/17 98400-IN $3,145.50 1120 101 1120 101 bill(s)is(are)true and correct and that the materials or services itemized thereon for which charge is made were ordered and received except Tuesday, November 28,2017 David Haboush Fire Chief I hereby certify that the attached invoice(s),or bill(s),is(are)true and correct and I have audited same in accordance with IC 5-11-10-1.6 120— Cost 20Cost distribution ledger classification if claim paid motor vehicle highway fund. Clerk-Treasurer Page: 1 Invoice Hoosier Fire Equipment,Inc. Invoice Number: 0098400-IN 4009 Montdale Park Drive Invoice Date: 11/21/2017 Valparaiso,Indiana 46383 (219)462-1707 Order Number: Order Date Salesperson: 0000 House Customer Number: CARM01 Sold To: Ship To: Carmel Fire Department Carmel Fire Department 2 Civic Square 2 Civic Square Carmel,IN 46032-7543 Carmel, IN 46032-7543 Confirm To: Customer P.O. Ship VIA F.O.B. Terms OUR DELIVERY DESTINATION Net 10 Item Code Unit Ordered Shipped Back Ordered Price Amount /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S 2003 KME PUMPER AS PER ATTACHED; SN:5340. /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S 2011 SEAGRAVE PUMPER AS PER ATTACHED;SN:78G45. /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S ALF 75'QUINT AS PER ATTACHED;SN: 0108975. /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S 2002 KME PUMPER AS PER ATTACHED; SN:5016. /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S 2011 SEAGRAVE PUMPER AS PER ATTACHED;SN:78G46. /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S 1996 KME PUMPER AS PER ATTACHED; SN:2930. /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S 1989 GRUMMAN 102'TOWER AS PER ATTACHED;SN: 18125. /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S 2016 PIERCE PUMPER AS PER ATTACHED;SN:29584-01. /SERVICE EACH 1.00 1.00 0.00 349.50 349.50 PERFORMED ANNUAL PUMP TEST ON CUSTOMER'S 2016 PIERCE PUMPER AS PER ATTACHED;SN:29584-02. r� I� Net Invoice: 3,145.50 Less Discount: 0.00 Freight: 0.00 Sales Tax: 0.00 Invoice Total: 3,145.50 ❑ HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC. PART,NQ"ANR/ORDESCRIPTION, � PRICE; 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/16/2017 DATE: 11/16/2017 ADDRESS: 2 Civic Square PROMISED: CUSTOMER 058675 CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB-MS PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR# KME Pumper 2003 5340 [Engine 34J 93,894.0 8955 LABOR REPAIR ORDER INSTRUCTIONS LABOR HOURS CHARGE Perform annual pump testing $ 325.00 Set up fee $ 19.50 ADDITIONAL PARTS SEE LIST ON BACK —4 PARTS TOTAL n=* $ SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. X TOTAL LABOR: $ 344.50 TOTAL PARTS: $ — MILES TRAVEL RATE PRICE ���a SUBLE7��1�1QRK $ NOT RESPONSIBLE FOR �." LOSS OR DAMAGE TO CARS OR ARTICLES $ 5.0000.��� LEFT IN CARS IN CASE TAX: OF FIRE,THEFT OR ANY OTHER CAUSE BEYOND SUBLET WORK TOTAL ,$ - "' OUR CONTROL. TOTAL'TRAVEL EXPENSES: $ .,` ', 5.00 TOTAL HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY VALPARAISO, IN 46383 GREENFIELD, IN 46140 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/16/2017 Address: 2 Civic Square Unit No#: Engine 340 City&St: Carmel, IN 46032 Engine: Gas: M Diesel: X❑ Place of Test: Carmel Maintenance Facility Temperature: 32 Serial# 5340 Apparatus Year&Make: 2003 KME Pumper Miles: 93,894.0 Engine Hrs: 9,825.4 Pump Model: QMAX150-23L Serial No: 84575 Pump Hours: 960.2 Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 12 Sec. Vacuum Test: 22.5 In.with 8 Inches drop in 5 minutes Test Auxiliary Cooler: yes Auto Pressure Control Type: governor Test-Max Increase: 10 P.S.I. Test Plate Readings: 1504 GPM at 150 PSI at 1381 RPM 1051 GPM at 200 PSI at 1480 RPM 750 GPM at 250 PSI at 1665 RPM Recommended Governed Engine Speed: 2400 RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2" Lines: 3 Pump Control Position: 1,2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 14:20 1380 150 flowmeter 1510 14:25 1400 150 flowmeter 1510 14:30 1388 150 flowmeter 1510 14:35 1379 150 flowmeter 1510 Overload Test: 14:40 1 1 1449 165 flowmeter 1560 Oil Pressure: 40 PSI Water Temp: 190 F. Vacuum: 10 In. Volts 13.5 70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2" Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 14:45 1509 200 flowmeter 1050 14:50 1504 200 flowmeter 1050 14:55 1506 200 flowmeter 1050 Oil Pressure: 38 PSI Water Temp: 185 F. Vacuum: 5.5 In. Volts 13.4 50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No.2-1/2" Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 15:00 1667 250 flowmeter 750 15:05 1665 250 flowmeter 750 15:10 1669 250 flowmeter 750 Oil Pressure: 39 PSI Water Temp: 183 F. Vacuum: 3 In. Volts 13.1 Barometric Pressure 30.23 Test Water Temperature 68 CERTIFIED Bl Troy Harmon TESTING ENGINEER ❑ HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC. QTY. PART NO.AND/OR DESCRIPTION PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/15/2017 DATE: 11/15/2017 ADDRESS: 2 CIVIC Square PROMISED: CUSTOMER ST2029 CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB-MS PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT I MILEAGE AR# Seagrave Pumper 2011 78G45 Engine 14111 56,175.0 8955 LABOR OURS REPAIR ORDER INSTRUCTIONS LABOR CHARGE Perform annual pump testing $ 325.00 Set up fee $ 19.50 ADDITIONAL PARTS SEE LIST ON BACK —4 PARTS TOTAL 10-111, $ - SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. X TOTAL LABOR: $ 344.50 TOTAL PARTS: $ - MILES TRAVEL RATE PRICE SUBLET WORK: $;NOT RESPONSIBLE FOR LOSS OR DAMAGE TO $ 5.00 _ TRAVEL EXP. $ 5.00 CARS OR ARTICLES LEFT IN CARS IN CASE T ' OF FIRE,THEFT OR ANY OTHER CAUSE BEYOND SUBLET WORK TOTAL $ - OURCONTROL. TOTAL TRAVEL EXPENSES: $ 5.00 TOTAL $ 349.50 HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE ® 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY VALPARAISO, IN 46383 GREENFIELD, IN 46140 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/15/2017 Address: 2 Civic Square Unit No#: Engine 341 City&St: Carmel, IN 46032 Engine: Gas: ❑ Diesel: X❑ Place of Test: Carmel Maintenance Facility Temperature: 44 Serial# 78G45 Apparatus Year&Make: 2011 Seagrave Pumper Miles: 56,175.0 Engine Hrs: 5,426.6 Pump Model: QMAX150-23L Serial No: A6794 Pump Hours: unknown Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 8 Sec. Vacuum Test: 22.5 In.with 2 Inches drop in 5 minutes Test Auxiliary Cooler: yes Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I. Test Plate Readings: 1510 GPM at 150 PSI at 1354 RPM 1051 GPM at 200 PSI at 1496 RPM 750 GPM at 250 PSI at 1636 RPM Recommended Governed Engine Speed: 2200 RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2"Lines: 3 Pump Control Position: 1,2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 13:25 1358 150 flowmeter 1510 13:30 1360 150 flowmeter 1510 13:35 1358 150 flowmeter 1510 13:40 1360 150 flowmeter 1510 Overload Test: 13:45 1 1 1423 165 flowmeter 1580 Oil Pressure: 50 PSI Water Temp: 180 1 F. Vacuum: 8.5 In. Volts 14.5 70% Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 1,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 13:50 1 1480 200 flowmeter 1060 13:55 1478 200 flowmeter 1060 14:00 1 1482 200 flowmeter 1060 Oil Pressure: 51 PSI Water Temp: 181 F. Vacuum: 4.5 In. Volts 14.3 50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No.2-1/2" Lines: 2 Pump Control Position: 1,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 14:05 1636 250 flowmeter 750 14:10 1637 250 flowmeter 750 14:15 1636 250 flowmeter 750 Oil Pressure: 52 PSI Water Temp: 183 F. Vacuum: 3 In. Volts 14.3 Barometric Pressure 29.88 Test Water Temperature 68 CERTIFIED 13 r Troy Harmon TESTING ENGINEER ❑ HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC. QT„Y: PART NO.AND/OR DESCRIPTION PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/15/2017 DATE: 1115/2017 ADDRESS: 2 Civic Square PROMISED: CUSTOMER K92637 CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB-MS PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR# ALF 75'Quint 2003 0108975 Engine 34 101,463.0 8955 LABOR REPAIR ORDER INSTRUCTIONS LABOR e �H06RS CHARGE Perform annual pump testing $ 325.00 Set up fee $ 19.50 ADDITIONAL PARTS SEE LIST ON BACK ®► PARTS 1TOTAL $ SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. X TOTAL i:ABOR: $ 344.50a TOTAL PARTS: $. MILES TRAVEL RATE PRICE SUBLET WORK: $ - NOT RESPONSIBLE FOR - - LOSS OR DAMAGE TO CARS OR ARTICLES $ 5.00 .TRAVEL EXP. $ 5.00 LEFT IN CARS IN CASE AX OF FIRE,THEFT OR ANY OTHER CAUSE BEYOND SUBLET WORK`TQTAL „ ? ouRcoNTROL. r TOTAL TRAVEL EXPENSES $ 5 OOe TOTAL ®� $,° '349 50 HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY VALPARAISO, IN 46383 GREENFIELD, IN 46140 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/15/2017 Address: 2 Civic Square Unit No#: Engine 342 City&St: Carmel, IN 46032 Engine: Gas: [] Diesel: X❑ Place of Test: Carmel Maintenance Facility Temperature: 45 Serial# 0108975 Apparatus Year&Make: 2003 ALF 75'Quint Miles: 101,463.0 Engine Hrs: 8,270.1 Pump Model: QMAX150-23S Serial No: 82481 Pump Hours: unknown Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: 2.3 Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 14 Sec. Vacuum Test: 22.5 In.with 2 Inches drop in 5 minutes Test Auxiliary Cooler: yes Auto Pressure Control Type: governor Test-Max Increase: 10 P.S.I. Test Plate Readings: 1504 GPM at 150 PSI at 1352 RPM 1051 GPM at 200 PSI at 1482 RPM 750 GPM at 250 PSI at 1629 RPM Recommended Governed Engine Speed: 2225 RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2"Lines: 3 Pump Control Position: 1,2,4 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 14:30 1358 150 flowmeter 1510 14:35 1370 150 flowmeter 1510 14:40 1365 150 flowmeter 1510 14:45 1368 150 flowmeter 1510 Overload Test: 14:50 1 1 1432 165 flowmeter 1570 Oil Pressure: 36 PSI Water Temp: 185 F. Vacuum: 9.5 In. Volts 13.9 70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 2,4 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 14:55 1 1489 200 flowmeter 1060 15:00 1 1486 200 flowmeter 1060 15:05 1 1487 200 1 flowmeter 1060 Oil Pressure: 36 PSI Water Temp: 189 F. Vacuum: 5.5 In. Volts, 13.9 50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No.2-1/2" Lines: 2 Pump Control Position: 2,4 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 15:10 1 1638 250 flowmeter 750 15:15 1642 250 flowmeter 750 15:20 1637 250 flowmeter 1 750 Oil Pressure: 37 PSI Water Temp: 183 F. Vacuum: 4 In. Volts 13.9 Barometric Pressure 29.86 Test Water Temperature 72 CERTIFIED 13� Troy Harmon TESTING ENGINEER F-1HOOSIERFIRE EQUIPMENT INC. ❑ HOOSIER FIRE EQUIPMENT, INC. ;;GlT,Y ,,PART,,NO� AND/OR;DE�SCR�PTIQN o p„a PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/15/2017 DATE: 11/15/2017 ADDRESS: 2 CIVIC Square PROMISED: CUSTOMER N058489 CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB-MS PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR# KME Pumper 2002 5016 Engine 3431 98,093.0 8955 LABOR REPAIR ORDER INSTRUCTIONS BOR HOURS CHARGE, Perform annual pump testing $ 325.00 Set up fee $ 19.50 ADDITIONAL PARTS SEE LIST ON BACK -4 PARTS TOTAL $ SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. X TOTAL LABOR: $ 344.50 TOTAL PARTS: MILES TRAVEL RATE PRICE °�"�� �`u SUBLET ORK ���� °� NOT RESPONSIBLE FOR 't � $������ft��y a��a��� LOSS OR DAMAGE TO Q; a ��„ • @��h �'\" CARS OR ARTICLES $ 5.00 LEFT IN CARS IN CASE OF FIRE,THEFT OR ANY TAX: OTHER CAUSE BEYOND SUBLET'WORKTOTAL $ = OURCONTROL. TOTAL TRAVEL EXPENSES:' $,' 5.00 TOTAL --I $ 349.50 HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY VALPARAISO, IN 46383 GREENFIELD, IN 46140 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/15/2017 Address: 2 Civic Square Unit No#: Engine 343 City&St: Carmel, IN 46032 Engine: Gas: 1-1 Diesel: MR Place of Test: Carmel Maintenance Facility Temperature: 41 Serial# 5016 Apparatus Year&Make: 2002 KME Pumper Miles: 98,093.0 Engine Hrs: 10,053.0 Pump Model: QMAX150-23L Serial No: 82415 Pump Hours: unknown Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 14 Sec. Vacuum Test: 22.5 In.with 6.5 Inches drop in 5 minutes Test Auxiliary Cooler: pass Auto Pressure Control Type: governor Test-Max Increase: 10 P.S.I. Test Plate Readings: 1504 GPM at 150 PSI at 1325 RPM 1051 GPM at 200 PSI at 1498 RPM 750 GPM at 250 PSI at 1662 RPM Recommended Governed Engine Speed: 2400 RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2" Lines: 3 Pump Control Position: 1,2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 11:10 1380 150 flowmeter 1510 11:15 1376 150 flowmeter 1510 11:20 1380 150 flowmeter 1510 11:25 1380 150 flowmeter 1510 Overload Test: 11:30 1 1 1450 165 flowmeter 1590 Oil Pressure: 35 PSI Water Temp: 180 F. Vacuum: 12 In. Volts 13.8 70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 11:35 1500 200 1 flowmeter 1050 11:40 1505 200 flowmeter 1050 11:45 1501 200 flowmeter 1050 Oil Pressure: 35 PSI Water Temp: 185 F. Vacuum: 7 In. Volts 13.7 50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No.2-1/2" Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 11:50 1655 250 flowmeter 750 11:55 165-4 -1 250 1 flowmeter 750 12:00 1656 1 250 1 flowmeter 750 Oil Pressure: 35 PSI Water Temp: 185 F. Vacuum: 5 In. Volts 13.7 Barometric Pressure 29.94 Test Water Temperature 70 CERTIFIED 13 r Troy Harmon TESTING ENGINEER ❑ HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC. <PART ANO ,AND LORaDES,CRI,PTION 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/16/2017 DATE: 11/16/2017 ADDRESS: 2 CIVIC Square PROMISED: CUSTOMER ST2030 0RnFR it CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB-MS PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR# Seagrave Pumper 2011 78G46 Engine 3441 49,770.0 8955 LABOR REPAIR ORDER INSTRUCTIONS LABOR HOURS CHARGE Perform annual pump testing $ 325.00 Set up fee $ 19.50 ADDITIONAL PARTS SEE LIST ON BACK am# PARTS TOTAL $ SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. X TOTAL LABOR: $ 344.50 TOTAL PARTS: $_,`b -, MILES TRAVEL RATE PRICE a' �` SUBETIAIORK $ '� � NOT RESPONSIBLE FOR LOSS OR DAMAGE TO a ' " @ CARS OR ARTICLES $ 500 ' ,TIVEL EXP $ ��`,' S;OO LEFT IN CARS IN CASE OF FIRE,THEFT OR ANY TAX: OTHER CAUSE BEYOND - SUBLET WORK TOTAL $ - ,. OUR CONTROL. TOTAL TRAVEL EXPENSES; „$, 5.00• TOTAL —111, $ 349.50 HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY VALPARAISO, IN 46383 GREENFIELD, IN 46140 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/16/2017 Address: 2 Civic Square Unit No#: Engine 344 City&St: Carmel, IN 46032 Engine: Gas: Diesel: X❑ Place of Test: Carmel Maintenance Facility Temperature: 32 Serial# 78G46 Apparatus Year&Make: 2011 Seagrave Pumper Miles: 49,770.0 Engine Hrs: 4,029.1 Pump Model: QMAX150 Serial No: A6793 Pump Hours: unknown Rated Capacity: . 1500 GPM Stages: 1 Pump Ratio: unknown Suction Size: 2/6" In. Length: 10/25' Ft. Lift: 2 Ft. Primed: 13 Sec. Vacuum Test: 22.5 In.with 7 Inches drop in 5 minutes Test Auxiliary Cooler: yes Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I. Test Plate Readings: 1510 GPM at 150 PSI at 1376 RPM 1051 GPM at 200 PSI at 1503 RPM 750 GPM at 250 PSI at 1644 RPM Recommended Governed Engine Speed: 2200 RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2"Lines: 3 Pump Control Position: 1,2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 8:40 1358 150 flowmeter 1510 8:45 1359 150 flowmeter 1510 8:50 1360 150 flowmeter 1510 8:55 1360 150 flowmeter 1510 Overload Test: 9:00 1 1 1428 165 flowmeter 1600 Oil Pressure: 52 PSI Water Temp: 185 F. Vacuum: 8.5 In. Volts 14.2 70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 9:05 1491 200 flowmeter 1060 9:10 1494 200 flowmeter 1060 9:15 1490 200 flowmeter 1060 Oil Pressure: 53 PSI Water Temp: 186 F. Vacuum: 5 In. Volts 13.9 50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 9:20 1642 250 flowmeter 750 9:25 1 1639 250 flowmeter 750 9:30 1 1643 250 flowmeter 750 Oil Pressure: 55 PSI Water Temp: 188 F. Vacuum: 3 In. Volts 14 Barometric Pressure 30.16 Test Water Temperature 58 CERTIFIED 13� Troy Harmon TESTING ENGINEER �J HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC. eutT°Y � ' � P+k? NtO;"f1Npa/C7R`DSCRIRt �QN v� k;PRICEa' \, 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/16/2017 DATE: 11/162017 ADDRESS: 2 Civic Square PROMISED: CUSTOMER 058491 ORDFR it CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR# KME Pumper 1996 2930 Engine 349 106,160.0 8955 E \�? ::':.Q J..m,.,.. \ 3 ?:a \a�\\�.: ��a \.'^",.a. �.a �,a. � ^ ..:mm ..: .�\ti:,a \. �i?x s,...:.re�\ �+`��. c..� \„a� \ \\\� ,..'.:�Ap�7i=•�W:a,.r. Perform annual pump testing $ 325.00 Set up fee $ 19.50 ADDITIONAL PARTS SEE LIST ON BACK a\\\, \qo \iaRm T,�.^a TvvOvYret\ai0u�.W .2�vJ \� \ „Ae SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. \\�xx \\ \\\\a \\a ata\\\ o ,\344 50 X TOTAL aoR "$ W1w4 Xh &&w n\\� " \SU„ 41 ?4RK� °`a wart u MILES TRAVEL RATE PRICE NOT RESPONSIBLE FOR +A a vA A v4 as v VV v aWav a V va vW a v A sx a v$ LOSS OR DAMAGE TO Q; 500a \ a n: LEFT IN CARS IN CASE a aqga' fva ,�\” ?x`V A��\ pv`y` W �"x,7,,',,7,_\7,y.a g\ ' OF FIRE,THEFT OR ANYa"aa:;a„u. OTHER CAUSE .....�,. 1w,.,.a OUR CONTROL \a . \ q\uW�...x,a.,\..�;.\\\,..,.:�,,.\,,\ax a\.\\a\as\..\"\\\\\..h..�....:..`.F#.,5,,\.�a..,,Q na a,„,,,•.... TOTAL \.,\ : a... a ^ HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY VALPARAISO, IN 46383 GREENFIELD, IN 46140 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/16/2017 Address: 2 Civic Square Unit No#: Engine 349 City&St: Carmel, IN 46032 Engine: Gas: 1-1 Diesel: XD Place of Test: Carmel Maintenance Facility Temperature: 32 Serial# 2930 Apparatus Year&Make: 1996 KME Pumper Miles: 106,160.0 Engine Hrs: 11,224.4 Pump Model: QSMG150-23L Serial No: 69971 Pump Hours: 1,247.2 Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown Suction Size: 2/6" In. Length: 10/25' Ft. Lift: 2 Ft. Primed: 11 Sec. Vacuum Test: 22.5 In.with 5 Inches drop in 5 minutes Test Auxiliary Cooler: yes Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I. Test Plate Readings: 1504 GPM at 150 PSI at 1417 RPM 1051 GPM at 200 PSI at 1533 RPM 750 GPM at 250 PSI at 1678 RPM Recommended Governed Engine Speed: 2400 RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2" Lines: 3 Pump Control Position: 1,2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 10:05 1420 150 flowmeter 1510 10:10 1420 150 flowmeter 1510 10:15 1420 150 flowmeter 1510 10:20 1420 150 flowmeter 1510 Overload Test: 10:25 1 1 1510 165 flowmeter 1570 Oil Pressure: 40 PSI Water Temp: 170 F. Vacuum: 10 In. Volts 13 70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 10:30 1530 200 flowmeter 1060 10:35 1530 200 flowmeter 1060 10:40 1530 200 flowmeter 1060 Oil Pressure: 28 PSI Water Temp: 190 F. Vacuum: 7.5 In. Volts 13.5 50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 10:45 1670 250 flowmeter 750 10:50 1 1670 250 flowmeter 750 10:55 1 1670 250 flowmeter 750 Oil Pressure: 28 PSI Water Temp: 190 F. Vacuum: 4.5 In. Volts 13.5 Barometric Pressure 30.19 Test Water Temperature 68 CERTIFIED Bl Troy Harmon TESTING ENGINEER HOOSIER FIRE EQUIPMENT, INC. HOOSIER FIRE EQUIPMENT, INC. TY q��\, SPAR NONND(pRtpISCRIP ION44 r? ICE 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/16/2017 DATE: 11/16/2017 ADDRESS: 2 Civic Square PROMISED: CUSTOMER 088012 npnF=p it CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB-MS PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR# Grumman 102'Tower 1989 18125 Ladder 340 54,997.0 8955 ..... \ `.'�1\\. \ k \.R(2` \ :.:C\ \ 1. !'�..R• ((+� l'� .\\\ \\ \ �5.. r\\\\... \�x baa g\\\ :,.,... \ Y �R5 a Perform annual pump testing $ 325.00 Set up fee $ 19.50 yy ADDITIONAL PARTS SEELISTLIST ON BACK 0-0 '1—Ar1T,�`\TO! 4:: \\ \ k\ � \��\\�\�1>� � �. u\\ :".`„ia� \ a\�\�:� �\9a;\\ Z \2\Cog,\� agg SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. A, $ vA v \A 1111,11 avw vy �” tc v�\\�� + X \\\�OAi LA�o $\ 344 5a,, a�, x„Ae vao,av ,aa. a \a a0avu ,a\k jv MILES TRAVEL RATE PRICE � �v�� B at/1�G1R{{ NOT RESPONSIBLE FOR �>" a\su tr'( .11A, 9.. . LOSS OR DAMAGE TO5.00 A\�V\ S a�G\Mada\� m VAVvAQFA ovA6ApAVvpvvv "�fx c CARS OR ARTICLESLEFT IN $ 5 00 � .� OF FIARS IN CASE RECTHEFT OR ANY \`. \ a \\... .\. \\;t �. \ \ \ "\ ,�a.. �\\ a m... :. \ \, c� ..... OTHER CAUSE BEY ND ..� \. \.. , a., a r..< \, x.\ \;. „ a, ,..a\. x.. v..\.. r \. � ..., \ \ .� \ ,\�....„ ,. .�. a\\ , x,. ,. ,a \ .. \ \.: ., a \ ::� ar ,\ \ .r,o �\ \ :e,.w, ak9 \\..,\\\ \\ as�: h \ �..'\o w \a:>u, a.. .. a. � a \\ \.....< \�\:,,.. .. ,. .. ...„. a",�. ,. \\a\ � \\ ,......4 ,. „a ;,a .::,OUR CONTROL. 0. ,.. .y\. \, a\ x, u ;. TOTAL � � .a \, \,.SUBLET\ ":O K TOTAL \ OT,.LTR VEL EXP `NS�S., as .00, \a � \1IV R \ r �\��\Xa /� F \\ � � \W w��.«:sx:a, ,-R\sv \v. .�a� �,.x'�\v�a..� S.y\\,.m vev. ;P'_x.a Aa,�.va,.; „a, .A"aaw"�\. ..vvA ,u,e"aa0ti a,��;�,�a sono,;a\ HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY VALPARAISO, IN 46383 GREENFIELD, IN 46140 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/16/2017 Address: 2 Civic Square Unit No#: Ladder 340 City&St: Carmel, IN 46032 Engine: Gas: Diesel: El Place of Test: Carmel Maintenance Facility Temperature: 34 Serial# 18125 Apparatus Year&Make: 1989 Grumman 102'Tower Miles: 54,997.0 Engine Hrs: 6,666.5 Pump Model: CMU YBX Serial No: 13977W Pump Hours: unknown Rated Capacity: 1500 GPM Stages: 2 Pump Ratio: 2.48 Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 8 Sec. Vacuum Test: 22.5 In.with 1 Inches drop in 5 minutes Test Auxiliary Cooler: yes Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I. Test Plate Readings: 1500 GPM at 150 PSI at 1468 RPM VOLUME MODE 1050 GPM at 200 PSI at 1563 RPM VOLUME MODE 750 GPM at 250 PSI at 1360 RPM PRESSURE MODE Recommended Governed Engine Speed: unknown RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2" Lines: 3 Pump Control Position: 1,2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 13:15 1430 150 flowmeter 1500 VOLUME MODE 13:20 1430 150 flowmeter 1500 VOLUME MODE 13:25 1430 150 flowmeter 1500 VOLUME MODE 13:30 1430 150 flowmeter 1500 VOLUME MODE Overload Test: 13:35 1 1 1510 165 flowmeter 1590 VOLUME MODE Oil Pressure: 45 PSI Water Temp: 190 F. Vacuum: 12 In. Volts 12.8 70% Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2" Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 13:40 1 1560 200 flowmeter 1060 VOLUME MODE 13:45 1560 200 flowmeter 1050_LL VOLUME MODE 13:50 1560 200 flowmeter 1060 1 VOLUME MODE Oil Pressure: 40 PSI Water Temp: 210 F. Vacuum: 6.5 In. Volts 13.2 50% Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No. 2-1/2" Lines: 2 Pump Control Position: 2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 13:55 1420 250 1 flowmeter 750 PRESSURE MODE 14:00 1420 250 flowmeter 750 PRESSURE MODE 14:05 1420 250 flowmeter 750 PRESSURE MODE Oil Pressure: 35 PSI Water Temp: 210 F. Vacuum: 4 In. Volts 13.2 Barometric Pressure 30.22 Test Water Temperature 72 CERTIFIED B`r Troy Harmon TESTING ENGINEER ❑ HOOSIER FIRE EQUIPMENT, INC. Fj HOOSIER FIRE EQUIPMENT, INC. v2YvPARTNQ'/1�1D(QI°ESCR2�TOIp , �PRIG,E 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/15/2017 DATE: 11/15/2017 ADDRESS: 2 Civic Square PROMISED: CUSTOMER 01674 ORDER 9 CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB-MS PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR p Pierce Pumper 2016 29584-01 Engine 346 12,587.0 8955 \\ \a W', \ ��PQ�! v:~•.0. ti Perform annual pump testing $ 325.00 Set up fee $ 19.50 ADDITIONAL PARTS SEE LIST ON BACK SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. vA�:vAA$,aa `:vv a'a v`vaT t sv vilAAApVAaleVvAas 2v`\vvC �' p ac �'K \ °"^xax ���` «vAsviaa2v ",t NOT RESPONSIBLE FOR MILES TRAVEL RATE PRICE LOSS OR DAMAGE TO 5.00 "ASSRA^` \��'' y�"' A�•SFI Q@00 A �Aa"pL*\F p \ CARS OR ARTICLES LEFT IN CARS IN CASE \\\\\`" ?\`p\�\\\, OF FIRE,THEFT OR ANY ,.".„.u.�a.,..\u.`'\.."..�e.;.w.„S\t\\.lt"y?„,a.e,�.l..\,.s..r....,.�.\v,.,_p...e\Ae�.o�es,�.x°h,}\\.p.,:.,\....:,,.a,tiA u�C\�t xV,�.a�....:.fi..a..\\xr\\1C*aaV`\ev\..„„�\�.,..:+.,:.,.,J..,,,,\\„S.U\teka\1t�tB,,..<...,.,,.,\�T�`Vt\.,0\Wc1ha,.r.e...,A,O\\�,,...:(t�,�.,�,.v,.V,.xi\�.O,,psTu'\.\..i.S,„s a\,c�„.\nv,,.,x.x.,�.\...JVwvuvu,A\\V\A\,\\.a...a..\,..,v�,a\.\\.a.,;\\\..s,.,,..,•..b..:,,..\�,\\OTHER CAUSE BEYOND Sp\..:,„.$..�.,\\4 EOURCONTROL.A \a .\\,„ta.ti.pvv4inpa\„:...ti..:.>..5:. 0.,m.\v0\\,0 :,a1... .dt ; HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY & VALPARAISO, IN 46383 GREENFIELD, IN 46140 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/15/2017 Address: 2 Civic Square Unit No#: Engine 346 City&St: Carmel, IN 46032 Engine: Gas: Diesel: X7I Place of Test: Carmel Maintenance Facility Temperature: 39 Serial# 29584-01 Apparatus Year&Make: 2016 Pierce Pumper Miles: 12,587.0 Engine Hrs: 993.0 Pump Model: QMAX150-23L Serial No: H10562 Pump Hours: 78.0 Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 8 Sec. Vacuum Test: 22.5 In.with 0" Inches drop in 5 minutes Test Auxiliary Cooler: pass Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I. Test Plate Readings: 1509 GPM at 150 PSI at 1418 RPM 1053 GPM at 200 PSI at 1540 RPM 750 GPM at 250 PSI at 1680 RPM Recommended Governed Engine Speed: 2400 RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2"Lines: 3 Pump Control Position: 1,2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 9:35 1390 150 flowmeter 1510 9:40 1400 150 flowmeter 1510 9:45 1400 150 flowmeter 1510 9:50 1406 150 flowmeter 1510 Overload Test: 9:55 1 1 1450 165 flowmeter 1570 Oil Pressure: 50 PSI Water Temp: 180 F. Vacuum: 9 In. Volts 13 70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 1,2 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 10:00 1510 200 flowmeter 1060 10:05 1500 200 flowmeter 1060 10:10 1510 200 flowmeter 1060 Oil Pressure: 50 PSI Water Temp: 180 F. Vacuum: 6.5 In. Volts 12.8 50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 1,2 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 10:15 1660 250 flowmeter 750 10:20 1680 250 flowmeter 750 10:25 1660 250 flowmeter 750 Oil Pressure: 52 PSI Water Temp: 187 F. Vacuum: 4.5 In. Volts 12.7 Barometric Pressure 29.98 Test Water Temperature 60 CERTIFIED Bti Troy Harmon TESTING ENGINEER ❑ HOOSIER FIRE EQUIPMENT, INC. ❑ HOOSIER FIRE EQUIPMENT, INC. QTY: PART NO. AND/OR DESCRIPTION PRICE 4009 Montdale Park Drive 3863 North Commercial Parkway Valparaiso, IN 46383 Greenfield, IN 46140 Phone: 219-462-1707 Phone: 317-891-8375 Toll Free: 800-552-2691 Toll Free: 888-436-6075 REPAIR ORDER NAME: Carmel Fire Department RECEIVED: 11/15/2017 DATE: 11/15/2017 ADDRESS: 2 Civic Square PROMISED: CUSTOMER 01675 nRnFR it CITY: Carmel, IN 46032 TERMS: MECHANIC: MOB-MS PHONE: MAKE: MODEL: YR. SERIAL NO. UNIT MILEAGE AR# Pierce Pumper 2016 29584-02 Engine 345 14,678.0 8955 LABOR LABOR"' REPAIR ORDER INSTRUCTIONS 10URS `° a CHARGE Perform annual pump testing $ 325.00 Set up fee $ 19.50 ADDITIONAL PARTS SEE LIST ON BACK —4 PARTS T..OTAL $: - SUBLET WORK PRICE I hereby authorize the above repair work to be done w/the necessary material,and hereby grant you and/or your employees permission to operate the car or truck herein described on streets,highways or elsewhere for the purpose of testing and/or Inspection. An express mechanic's lien is hereby acknowledged on above car or truck to secure the amt.of repairs thereto. X TOTAL LABOR: $ 344.50 TOTAL PARTS: $ - MILES TRAVEL RATE PRICE SUBLET WORK`. $ - - NOT RESPONSIBLE FOR LOSS OR DAMAGE TO $ 5.00 "TRAVEL EXP. $ „. '5.00 CARS OR ARTICLES LEFT IN CARS IN CASE TAX: OF FIRE,THEFT OR ANY „ „ SUBLET WORK TOTAL ouRcorlTao�BEYON TOTAL TRAVEL EXPENSES �i 5 OO'a TOTAL 349.50°` HOOSIER FIRE EQUIPMENT, INC. MAIN OFFICE MID-STATE OFFICE 4009 MONTDALE PARK DR. 3863 N. COMMERCIAL PKWY VALPARAISO, IN 46383 GREENFIELD, IN 46140 �� 800-552-2691 888-436-6075 PUMP TEST REPORT Customer: Carmel Fire Department Date: 11/15/2017 Address: 2 Civic Square Unit No#: Engine 345 City&St: Carmel, IN 46032 Engine: Gas: M Diesel: 0 Place of Test: Carmel Maintenance Facility Temperature: 43 Serial# 29584-02 Apparatus Year&Make: 2016 Pierce Pumper Miles: 14,678.0 Engine Hrs: 1,236.0 Pump Model: QMAX150-23L Serial No: H10562 Pump Hours: 95.0 Rated Capacity: 1500 GPM Stages: 1 Pump Ratio: unknown Suction Size: 6 In. Length: 10 Ft. Lift: 2 Ft. Primed: 8 Sec. Vacuum Test: 22.5 In.with 0.5 Inches drop in 5 minutes Test Auxiliary Cooler: pass Auto Pressure Control Type: valve Test-Max Increase: 10 P.S.I. Test Plate Readings: 1509 GPM at 150 PSI at 1410 RPM 1053 GPM at 200 PSI at 1533 RPM 750 GPM at 250 PSI at 1657 RPM Recommended Governed Engine Speed: 2400 RPM Capacity test-GPM 1500 PSI: 150 Tip Size: FM In. Test Time: 20 Min. No.2-1/2"Lines: 3 Pump Control Position: 1,2,3 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 12:05 1400 150 flowmeter 1510 12:10 1405 150 flowmeter 1510 12:15 1395 150 flowmeter 1510 12:20 1400 150 flowmeter 1510 Overload Test: 12:25 1 1 1440 165 flowmeter 1,570 Oil Pressure: 50 PSI Water Temp: 190 F. Vacuum: 10 In. Volts 13.8 70%Cap.Test-GPM 1050 PSI: 200 Tip Size: FM In. Test Time: 10 Min. No.2-1/2"Lines: 2 Pump Control Position: 1,2 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 12:30 1530 200 flowmeter 1060 12:35 1520 200 flowmeter 1060 12:40 1520 200 flowmeter 1060 Oil Pressure: 50 PSI Water Temp: 180 F. Vacuum: 5.5 In. Volts 13.8 50%Cap.Test-GPM 750 PSI: 250 Tip Size: FM In. Test Time: 10 Min. No.2-1/2" Lines: 2 Pump Control Position: 1,2 Time Counter Eng. RPM Pump Press. Pitot GPM Notes 12:45 1650 250 flowmeter 750 12:50 1655 250 flowmeter 750 12:55 1650 250 flowmeter 750 Oil Pressure: 50 PSI Water Temp: 190 F. Vacuum: 4 In. Volts 13.8 Barometric Pressure 29.91 Test Water Temperature 70 CERTIFIED 13 r Troy Harmon TESTING ENGINEER