Loading...
HomeMy WebLinkAbout04010026 Building Plans-lo B.L. DOER, D.D.S. 110 N. RANGE LINE RD. 1w 4.0 opt 0 KEY PLAN SCALE: NTS N W-* S I Builders, Inc. Commercial Contractors 5333 West 86th Street Indianapolis, Indiana 46268 317-872-4181 317-334-0146 (F) www.kortbuilders.com Certified By: M O S owvZ YCARMEL, INDIANA 46032 ;; -jQO � CO DRAWING INDEX cOV COVER Al DEMOLITION PLAN & CONSTRUCTION/ FINISH PLAN A2 REFLECTED CEILING PLAN &ELEVATIONS/ DETAILS TA TL S U L9 M 11 TT/4 L SEI O D D w 0 �J m Revisions: Job Number: XXXXX Drawing Name: COVER Drawing Number: N ry O W NO z'q4- �< z wQ �o zz Q- rJ w z� oQ U IT- cov ■ GENERAL DEMOLITION NOTES 2 \ y/ (( i A. ALL DEMOLITION ITEMS SHALL BE CONSIDERED PROPERTY OF THE OWNER UNTIL SUCH A TIME O \ O VERIFICATION HAS BEEN MADE AS TO THOSE ITEMS NOT TO BE RETAINED BY THE OWNER PRIOR TO RR I ( REMOVAL FROM THE SITE. ALL ITEMS NOT TO BE RETAINED SHALL BE REMOVED COMPLETELY FROM THE OFFICE O4 102 ( ( SITE BY THE GENERAL CONTRACTOR. ,AREA AREA AREA DR. POEf� B. THE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY PARTITIONS AND TEMPORARY DOORS AS H I J AREA 1 04 ( O O O INDICATED ON THIS DEMOLITION PLAN, OR AS DEEMED NECESSARY BY THE OWNER. THEY SHALL BE N.I.C. N N. C. ) O — J O MAINTAINED, WITH ANY DAMAGE REPAIRED IMMEDIATELY, TO AVOID MIGRATION OF DUST INTO THE 0� ADJOINING AREAS. E �� 1 4 �� 1 4� . 108 I I I Q C. GENERAL CONTRACTOR TO VERIFY DUCTWORK OR PIPING PENETRATIONS THROUGH WALLS ABOVE AREA ) CEILING. IF PENETRATIONS OCCUR AND DUCTWORK OR PIPING IS TO BE REMOVED OR RELOCATED, FILL 9 C. C 10 / WAITING AREA IN OPENINGS TO BE FLUSH WITH AND OF THE SAME MATERIAL AS THE SURROUNDING WALL. 13 ) 101 D. MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN A MANNER SUITABLE TO ACCEPT NEW FINISHES O AND OR SURFACES. REFER TO ARCHITECTURAL PLANS, SPECIFICATIONS, AND DETAILS FOR SPECIFIC C [. _ –IINFORMATION REGARDING APPLICATION OF NEW MATERIAL. 1 AREA < ELEC. o G PAN Q (I i E. SALVAGE ALL REMOVED DOORS AND FRAMES FOR OWNER, OR REUSE IN THE SPACE. REPAIR AND/OR \ \ 1 4 11 AREA 14 CLOSET M ECH. ) 1 ( RESTAIN DOORS FOR RE -USE IF CONDITION OF SUCH WILL ALLOW. VERIFY ANY QUESTION WITH OWNER. N.I.C. Q -�� 105 N.I.C. CLOSET O AREA ��,--__-___ 103 GENERAL NOTES CLOSET AR%A//107 �1I 4 N.I.C. oOO AREA N.I.C. A. ALL WORK IS TO BE COMPLETED IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, EDEMO EXISTING FLOOR MATERIAL IN RULES, REGULATIONS, AND STANDARDS, INCLUDING, BUT NOT LIMITED TO: THE INDIANA BUILDING CODE, ALL AREAS OF WORK. LEVEL, AND RECEPTION THE INDIANA CODES, THE INDIANA FIRE CODES, THE AMERICANS WITH DISABILITIES ACT (ADA), N • I • C • PREPARE SUBSTRATE TO RECEIVE UNIVERSAL BUILDING CODE, AND APPLICABLE TRADE STANDARDS. ALL APPLICABLE RULES AND NEW FINISH AS SPECIFIED. 100 REGULATIONS ARE TO BE THE MOST CURRENT ADOPTED EDITIONS. MECH. CLOSET B. ALL DIMENSIONS ARE SHOWN ON THE DRAWINGS. ANY DIMENSIONS NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED WITH THE GENERAL CONTRACTOR. DO NOT SCALE DIMENSIONS ON N. 1. C. O THE DRAWINGS. ALL DIMENSIONS ARE TO THE FACE OF GYPSUM BOARD, MASONRY/CONCRETE WALLS, AREA O /%l OR CENTERLINE OF COLUMNS UNLESS NOTED OTHERWISE. A // C. FINISHED DOOR OPENINGS IN NEW PARTITIONS SHALL BE SET 6" FROM ADJACENT PERPENDICULAR N.I.C. UP PARTITIONS, UNLESS NOTED OTHERWISE. D. PROVIDE BLOCKING IN WALLS TO ACCOMMODATE ALL CASEWORK AND WALL MOUNTED EQUIPMENT. AREA E. UNLESS OTHERWISE NOTED, ALL NEW WALL CONSTRUCTION SHALL BE: 3 518" METAL STUD WALL D CONSTRUCTION 16" O.C. BRACED TO THE CEILING ABOVE. FASTEN 5/8" DRYWALL SHEATHING TO BOTH SIDES OF METAL STUDS WITH METAL SCREW FASTENERS FOR DRYWALL ON METAL STUD CONSTRUCTION. 12 201 -nil DEMOLITION PLAN SCALE: i/a._V_o. CONSTRUCTION/ FINISH PLAN, SCALE: I/4•44 FINISH SPECIFICATIONS WALLS PT -1 MANUFACTURER: T.B.D. STYLE: T.B.D. NUMBER: T.B.D. COLOR: T.B.D. PT -2 MANUFACTURER: T.B.D. STYLE: T.B.D. NUMBER: T.B.D. COLOR: T.B.D. PT -3 MANUFACTURER: T.B.D. STYLE. T.B.D. NUMBER: T.B.D. COLOR: T.B.D. FLOORS CPT -1 MANUFACTURER: T.B.D. STYLE: S8/ YD. BUDGET MATERIAL NUMBER: T.B.D. COLOR: T.B.D. VCT -1 MANUFACTURER: ARMSTRONG STYLE: IMPERIAL TEXTURE STANDARD EXCELON NUMBER: T.B.D. COLOR: T.B.D. BASE VB -1 MANUFACTURER: VPI STYLE: a VINYL COVE BASE NUMBER: T.B.D. COLOR: T.B.D. F. REPAIR ALL EXISTING DRYWALL IN AREAS OF WORK AND PREPARE TO RECEIVE NEW PAINT FINISH. KEYED NOTED G. ALL EXISTING ELECTRICAL TO REMAIN 'AS -IS'. O ALIGN FINISHED FACES. [WALL TYPE SYMBOLS LEGEND 2 DEMO EXISTING DOOR AND REPLACE W/ NEW ADA ACCESSIBLE DOOR & HARDWARE, STYLE T.B.D.. O VERIFY MEASUREMENTS OF OPENING PRIOR TO ORDER. EXISTING CONSTRUCTION TO BE REMOVED 3O MODIFY EXISTING CASED OPENING TO ACCOMMODATE, OWNER PROVIDED 30" PAIR OF SEGMENTED CLEAR GLASS DOORS. EXISTING CONSTRUCTION TO REMAIN 4O DEMO EXISTING PLUMBING. NEW WALL PARTITION 25 GA - 2 1 /2"M lI? t6" O.C. WITH 5/B" GYPSUM WALL REMOV€ EXIS SYSTI M. REPASIfARI)IM iNG ABOVE AS NEEDED AND BOARD ON EACH SIDE: TERMINATED 0 THE CEILING, WITH INSULATION IN STUD CAViTITES. PREPARE TO RECIEVE NEW PAINT FINISH. NEW 5/8" DRYWALL TO BE LAMINATED OVER EXISTING WALL O LEVEL EXISTING FLOOR. O NEW RESTROOM TO RECEIVE VINYL COMPOSITION TILE FLOORING 'VCT 1' DOOR SCHEDULE Builders, Inc. DOOR NO. - AND VINYL BASE, VB -1 . 317-872-4181 - 317-334-0146 (F) FINISHNOTES O ENCASE EXISTING BEAM IN DRYWALL. MAT'L. FINISH O NEW BULKHEAD TO BE PAINTED TO MATCH ADJACENT WALLS. A. PROCEEDING WITH THE INSTALLATION OF FINISHES WILL BE CONSTRUED THAT THE INSTALLER AND/OR 10 NEW RECEPTION DESK CONFIGURATION T.B.D. MILLWORK PROVIDED BY WASSON CABINET CO. (317)887-0852. VIF FINISHER HAS INSPECTED AND ACCEPTED THE SUBSTRATE FOR RECEIVING THE WORK. NO CHANGE FLUSH VERIFY ELECTRICAL/ COMMUNICATIONS NEEDS WITH OWNER EQUIPMENT. T.B.D. ORDER WILL BE ISSUED TO RECTIFY CONCEALED, UNKNOWN CONDITIONS OR UNSATISFACTORY T.B.D./ LOCKSET 102 36" SUBSTRATE ONCE THE FINISH WORK HAS PROCEEDED. 11 PROVIDE NEW EXHAUST FAN/ LIGHT COMBO IN CEILING ABOVE. REINSTALL EXISTING VANITY LIGHT AS B. T.B.D. T.B.D. SHOWN ABOVE MIRROR. 104a USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES. 12 EXISTING CEILING TO REMAIN. C. FLOORING CONTRACTOR TO LEVEL EXISTING SUBSTRATE AS NEEDED TO ACCEPT NEW FLOORING MATERIAL AND PROVIDE SEAMING DIAGRAM FOR CARPET LAYOUT FOR OWNER APPROVAL PRIOR TO 13 MODIFY EXISTING CASED OPENING TO 36"W. T.B.D./ PRIVACY INSTALLATION. 14 EXISTING CAS® OPENING TO REMAIN. D. PAINT ALL GRILLES, FIRE EXTINGUISHER CABINETS, ETC., TO MATCH SURFACE ON WHICH THEY OCCUR. OWN. PROV. T.B.D. T.B.D. T.B.D./ PRIVACY I S NEW DEDICATED DUPLEX OUTLET FOR OWNER PROVIDED WALL -MOUNTED PANORAMIC X-RAY. E. USE RUBBER REDUCER STRIPS WHERE VCT TRANSITIONS TO CARPET. CENTER TRANSITION STRIP UNDER FLUSH ENTRY T.B.D. CENTERLINE OF DOOR OR CENTERLINE OF OPENING, WHICHEVER APPLIES. T.B.D./ LOCKSET 106 F, CENTER ALL APPLICABLE CARPET LINES UNDER CENTERLINE OF DOOR (WHILE IN CLOSED POSITION). 1-3/4" FLUSH G. ALL AREAS OF WORK TO RECEIVE NEW PAINT FINISH, UNLESS NOTED OTHERWISE. T.B.D. T.B.D./ LOCKSET H. ALL AREAS OF WORK TO RECEIVE NEW CARPET, 'CPT -1' AND VINYL BASE, 'VB -1', UNLESS NOTED OTHERWISE. DOOR SCHEDULE Builders, Inc. DOOR NO. DIMENSIONS 317-872-4181 - 317-334-0146 (F) www.kortbuild6rs.com TYPE CONST. MAT'L. FINISH HARD:NARE WIDTH HT. THK. 100 32" VIF VIF 1-3/4" FLUSH ENTRY T.B.D. T.B.D. T.B.D./ LOCKSET 102 36" 80" 1-3/4" FLUSH SOLID CORE T.B.D. T.B.D. T.B.D./ PRIVACY 104a 32" 80" 1-314" FLUSH SOLID CORE T.B.D. T.B.D. T.B.D./ PRIVACY 104b (2) 317' VIF VIF FLUSH OWN. PROV. T.B.D. T.B.D. T.B.D./ PRIVACY 105 36" 80" 1-3/4" FLUSH ENTRY T.B.D. T.B.D. T.B.D./ LOCKSET 106 36" 80" 1-3/4" FLUSH SEG. GLASS T.B.D. T.B.D. T.B.D./ LOCKSET 1. ALL HARDWARE SHALL COMPLY WITH INDIANA HANDICAPPED ACCESSIBILITY CODES. J. ALL HARDWARE TO BE LEVER TYPE (WHERE APPLICABLE), FINISH T.B.D. K. DOORS NOT INDICATED BY DOOR NUMBER DESIGNATION ARE EXISTING. L. ALL DOOR SIZE DIMENSIONS GIVEN ARE APPROXIMATE. DOOR SUPPLIER SHALL VERIFY EXACT REQUIREMENTS. 11 KEY PLAN SCALE: Nis C Builders, Inc. Commercial Contractors 5333 West 86th Street Indianapolis, Indiana 46268 317-872-4181 - 317-334-0146 (F) www.kortbuild6rs.com Dr. .coos 1015 Certified By: S O04 C14 A - !'O �i1 cV ii O w OJ m • • ON ry O L1 z� JQ �z WQ W 0o zz Q ` � J W z� oU • Revisions: Job Number. XXXXX Drawing Name: DEMO. PLAN & CONST./ FINISH PLAN Drowing Number. Al C