Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
No Label at the Table Plans
www.buildwithtrace.net Scale Project number Date Drawn by Checked by C&T Design & Equipment 2750 Tobey Drive Indianapolis, Indiana 317.898.9602 12/8/2017 2:35:49 PM 100 Index Sheet New Restaurant No Label at the Table 12/4/2017 MNM Checker Sheet List Sheet Number Sheet Name Sheet Issue Date 100 Index Sheet 12/08/17 101 Floor Plan/RCP 12/04/17 K1 Foodservice Equipment Layout 11/28/17 K2 Electrical Rough-In Plan 11/28/17 K3 Plumbing Rough-In Plan 11/28/17 K4 Special Conditions Plan 11/28/17 No. Description Date 4 Retail 100 Existing Restroom 101 Existing Kitchen 102 Storage 103 11 11 11 11 11 1 2 2 4 5 3 16' - 3 1/2" 55' - 4" 100-1 100-2 101-1 103-1 102-1 33 33 33 3 8' - 1" 6' - 2" 8' - 6" 4' - 0" 6' - 8 13/16" 6' - 10" 6' - 8 1/2" 7' - 0" 7' - 10" 6 3 2' - 1" 9' - 10" 4 101 8 10 10 10 10 9 9 9 9 9 9 6 6 7 4 101 New Exhaust Diffuser 1i Partition Tag Keynote Sheet Legend X 1 Hr Rated Wall 1 1 1 Level 1 0' - 0" Roof 14' - 0" 2 New exhaust fan Refer to K series drawings www.buildwithtrace.net Scale Project number Date Drawn by Checked by C&T Design & Equipment 2750 Tobey Drive Indianapolis, Indiana 317.898.9602 1/4" = 1'-0" 12/22/2017 5:40:42 PM 101 Floor Plan/RCP New Restaurant No Label at the Table 12/4/2017 MNM 1/4" = 1'-0" 2 Level 1 1/4" = 1'-0" 3 RCP Keynote Legend 1 Remove Existing Wall 4 Repaint Existing Wall to 10' AFF (Typ.) 6 New 3 5/8" Bulkhead 7 Exposed to Deck Above 8 New 2' x 4' ACT Ceiling with Washable Tile 9 Replace Existing Lights with LED Fixtures 10 New LED Fixtures 11 New Convenience Outlets (Final Location TBD) Reference K-Series Drawings for Equipment & Blocking Requirements Partition Legend Type Mark Description 1 Existing Exterior Wall 2 Existing 1 Hr Rated Wall - Confirm Construction and Restore as Necessary to Acheive 1 Hr Rating 3 Existing Non-Rated Wall to Remain 4 New 3 5/8" Metal Stud Wall to 48" AFF 5 New 3 5/8" Metal Stud Wall to Deck Above 1/Wall4" = 1'-0" 6 Existing Exterior 1 Level 1 Existing Conditions/Demo No. Description Date Door Schedule Mark Width Height Frame Material Finish Description 100-1 3' - 0" 7' - 0" Aluminum Tempered Glass Existing Door to Remain 100-2 3' - 0" 7' - 0" Hollow Metal Laminate New Double Passage Door 101-1 3' - 0" 7' - 0" Hollow Metal Wood Veneer Existing Door to Remain 102-1 3' - 0" 7' - 0" Hollow Metal Painted Hollow Metal Existing Door to Remain 103-1 3' - 0" 7' - 0" Hollow Metal Wood Veneer Existing Door to Remain 1/4" = 1'-0" 4 Section 1