Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
04030128 Building Plans
ARCHITECT: kalcso 280 E. 96TH STREET, SUITE 200 i LLPA INDIANAPOLIS, INDIANA 46240 (317) 848.7800 (317) 574L0057 FAX CONTRACTOR: VAWADue CONSTRUCTION 600 E. 96th STREET SUITE 100 INDIANAPOLIS, IN 46240 PHONE: (317)808-6000 INDEX OF DRAWINGS ❑ xww m 1% w m [� wiwn somm a,E CMA& KEYPLAN SCALE: NOT TO SCALE NORTH I\ol A E F I ONE PARKWOOD SPECIFICATIONS AND GENERAL NOTES 0 CONTRACT CONDITIONS 0.1 THE GENERAL CONDITIONS SHALL BE AIA DOCUMENT A201 - 1987 EDITION, ENTITLED "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION". THIS DOCUMENT MAY BE OBSERVED IN THE OFFICE OF THE ARCHITECT. INCLUDED IN THE GENERAL CONDITIONS ARE RESPONSIBILITIES OF THE CONTRACTOR WHICH MAY BE PARAPHRASED AS FOLLOWS: 3.2 STUDY THE CONTRACT DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND REPORT DISCREPANCIES BEFORE PROCEEDING WITH CONSTRUCTION. 3.3 SUPERVISE, DIRECT AND COORDINATE THE WORK, WITH SOLE RESPONSIBILITY AND CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. 3.7 OBTAIN AND PAY FOR THE BUILDING PERMIT AND NECESSARY GOVERNMENTAL FEES, LICENSES AND INSPECTIONS. 3.14 CUT AND PATCH EXISTING SURFACES TO MATCH EXISTING ADJACENT SURFACES, USING EQUAL QUALITY MATERIALS AND WORKMANSHIP. 10.1 INITIATE, MAINTAIN AND SUPERVISE PROJECT SAFETY PRECAUTIONS AND PROGRAMS, WHICH ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 0.2 WORK MUST COMPLY WITH APPLICABLE LAWS, CODES, ORDINANCES, RULES AND REGULATIONS. 0.3 ALL MATERIALS AND EQUIPMENT SHALL BE OF INDUSTRY STANDARD QUALITY, WHETHER SPECIFIED OR NOT, AND WITHIN THE LIMITATIONS OF THE CONTRACT DOCUMENTS, TO CAUSE THE INSTALLATION TO FUNCTION IN ACCORDANCE WITH THE INTENTION AND OBJECTIVE OF THE FINISHED PROJECT. 0.4 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, PROVIDE THE SIZING OF INTERCONNECTING FACILITIES, SUCH AS PIPING, DUCTS AND WIRING, BETWEEN PIECES OF EQUIPMENT IN ORDER TO UTIUZE THE SPECIFIED CAPACITIES OF THE EQUIPMENT. 0.5 WHEN NOT INDICATED IN THE CONTRACT DOCUMENTS, THE STANDARDS ESTABLISHED BY THE RECOGNIZED TRADE ASSOCIATION HAVING JURISDICTION FOR THE PRODUCT INCLUDED IN THE PROJECT SHALL GOVERN THE WORK. 0.6 NOT ALL ITEMS INDICATED ON THE DRAWINGS ARE INCLUDED IN THESE SPECIFICATIONS. IN THE CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER ELEMENT NOT CLARIFIED BY ADDENDUM, THE BETTER QUALITY OR GREATER QUANTITY OF WORK SHALL BE PROVIDED IN ACCORDANCE WITH THE ARCHITECT'S INTERPRETATION. 0.7 INSTALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 1 GENERAL REQUIREMENTS 1.1 WORK SHALL BE PERFORMED DURING REGULAR BUSINESS HOURS WHENEVER POSSIBLE. WORK INVOLVING OVERTIME, NON -REGULAR BUSINESS HOURS SHALL BE COORDINATED WITH BUILDING MANAGEMENT. 1.2 THE CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK BY OTHERS INCLUDING BUT NOT LIMITED TO TELEPHONE/DATA, SECURITY, FURNITURE AND 'FURNISHED AND/OR INSTALLED' ITEMS. CONTRACTOR SHALL COORDINATE EXACT LOCATIONS AND SHALL DO THE CUTTING, FITTING, AND PATCHING THAT MAY BE REQUIRED TO MAKE THE PARTS OF THE WORK WHICH WILL RECEIVE THE WORK OF OTHERS AS SHOWN OR REASONABLY IMPLIED BY THE DRAWINGS AND SPECIFICATIONS. 1.3 CUTTING OF EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. 1.4 SUBMIT SHOP DRAWINGS ( OR SUBMITTALS ) TO THE ARCHITECT FOR THE FOLLOWING ITEMS: 1 METAL FABRICATIONS. 2 ARCHITECTURAL WOODWORK, INCLUDING TRIM AND CABINETS. .3 DOORS, FRAMES AND HARDWARE. .4 SUSPENDED ACOUSTICAL CEILING SYSTEMS ( 6' X 6' ACOUSTICAL PANEL ). .5 VCT FLOORING AND BASE ( COLOR SAMPLES ). .6 CARPET ( DYE LOT CUTTING AND SEAMING DIAGRAMS }. .7 PAINT ( 6' X 6" ON ACTUAL SURFACE ). .8 WALLCOVERINGS ( 9' X 9' DYE LOT CUTTING ). .9 SIGNAGE ( SAMPLE SIGN ). .10 LIGHT FIXTURES ( CATALOG CUTS ). 1.5 TEMPORARY UTILITIES, INCLUDING WATER, SANITARY FACILITIES, TEMPORARY ENCLOSURES, ARE PROTECTION, HEAT AND POWER WILL BE PROVIDED BY THE OWNER, SUBJECT TO THE OWNER OR THE OWNER'S AGENT'S DIRECTION. COMPLY WITH SPECIFIC BUILDING CONSTRUCTION RULES PUBLISHED BY THE OWNER OR THE OWNER'S AGENT. 1.6 THE CONTRACTOR SHALL PROTECT THE BUILDING PREMISES AND OCCUPANTS ON THE PROJECT SITE FROM DAMAGE. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN NECESSARY COVERINGS, BOARDS, TEMPORARY PARTITIONS, AND DOORS AS REQUIRED TO PROTECT EXISTING WORK, MATERIALS, AND FINISHES TO REMAIN AT THE JOB SITE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR DAMAGES ATTRIBUTABLE TO HIS OPERATION, REPAIRS, OR REPLACEMENT WITHOUT ADDITIONAL CHARGE TO THE PARTY AFFECTED. 1.7 THE CONTRACTOR SHALL MAINTAIN FOR THE ENURE LENGTH OF HIS CONTRACT EXITS, EXIT LIGHTING, ARE PROTECTIVE DEVICES AND ALARMS TO CONFORM TO LOCAL BUILDING CODE REQUIREMENTS. 1.8 SUBSTITUTION FOR NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. IF A SUBSTITUTION IS PROPOSED, SUBMIT THE FOLLOWING INFORMATION: .1 PROVIDE COMPLETE PRODUCT DATA, DRAWINGS AND DESCRIPTIONS OF PRODUCTS, AND FABRICATION AND INSTALLATION PROCEDURES. .2 PROVIDE SAMPLES WHERE APPLICABLE OR REQUESTED. 3 PROVIDE COMPLETE COORDINATION INFORMATION, INCLUDING ALL CHANGES REQUIRED IN OTHER ELEMENTS OF THE WORK TO ACCOMMODATE THE SUBSTITUTION. .4 PROVIDE A STATEMENT INDICATING HOW THE SUBSTITUTION WILL AFFECT THE CONTRACT SUM AND CONTRACT TIME. 1.9 STORE MATERIALS ON SITE PRIOR TO INSTALLATION, AND ALLOW TIME FOR THOR ADJUSTMENT TO AVOID SHRINKAGE OR SWELLING. 1.10 THE CONTRACTOR SHALL INCLUDE IN HIS BID AND SHALL ARRANGE FOR HOISTING, CARTING, STANDARD AND OVERTIME SERVICES BY THE BUILDING MANAGEMENT AND OVERTIME CHARGES AND EXPENSES WHEN REQUIRED DUE TO BUILDING MANAGEMENT REQUIREMENTS. SUITE 580 1.11 PERFORM FINAL CLEANING, EMPLOYING EXPERIENCED PROFESSIONAL CLEANERS. CLEAN EACH SURFACE OR UNIT OF WORK TO THE CONDITION EXPECTED FROM A COMMERCIAL BUILDING CLEANING AND MAINTENANCE PROGRAM IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 1.12 PROVIDE OPERATING AND MAINTENANCE MANUALS WITH INFORMATION NECESSARY FOR THE SAFE AND EFFICIENT OPERATION AND MAINTENANCE OF EQUIPMENT AND OPERATING SYSTEMS CALLED FOR IN THE CONTRACT DOCUMENTS, AND INFORMATION RELATIVE TO THE INSPECTION, CARE AND MAINTENANCE OR REPAIR OF ARCHITECTURAL PRODUCTS AND FINISHES WHICH ARE OTHER THAN BUILDING STANDARD. 2 DEMOLITION 2.1 COORDINATE DEMOUTION WITH CONSTRUCTION PLANS TO DETERMINE EXTENT OF WORK. PROVIDE DEMOLITION SUFFICIENT FOR SUITABLE BONDING/PATCHING OF EXISTING CONSTRUCTION TO REMAIN WITH NEW WORK. 2.2 WHERE WORK INCLUDES REMOVAL OF EXISTING CONSTRUCTION OR EQUIPMENT, OR REMOVAL AND PATCHING, REMOVAL AND REPLACEMENT, OR REMOVAL AND RELOCATION, SURFACES LEFT EXPOSED IN RELATION TO SUCH WORK SHALL HAVE ANY EXCESS MATERIALS REMOVED, AND SURFACES SHALL BE PREPPED AND FINISHED TO MATCH EXISTING ADJACENT SURFACES, INCLUDING WITH REGARD TO MATERIALS AND WORKMANSHIP. ADJACENT ITEMS SHALL BE REMOVED AND RELOCATED TO ALLOW SUCH WORK. NO CHANGE ORDER WILL BE ISSUED FOR ADDITIONAL WORK RELATED TO SUCH ACTIVITIES. 2.3 WHERE WORK INCLUDES REMOVAL AND RELOCATION, RELATED MECHANICAL AND ELECTRICAL CONNECTIONS AND TERMINATIONS SHALL BE INCLUDED. 2.4 REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED BY THE DRAWINGS. 2.5 ON EXISTING -CONSTRUCTION -TO -REMAIN, THOROUGHLY REMOVE ADHESIVE RESULTING FROM THE REMOVAL OF SURFACE APPLIED FINISHES, INCLUDING VINYL BASE, CARPET TILES, ETC. CHEMICALS AND METHODS TO REMOVE THE ADHESIVE SHALL BE COMPATIBLE WITH NEW FINISHES. 2.6 EXISTING ACOUSTICAL CEILING GRID, SUPPORT SYSTEM AND TILES SHALL REMAIN, EXCEPT IN THOSE AREAS DAMAGED DURING CONSTRUCTION OR NOTED TO BE REPAIRED. 2.7 SALVAGE AND TURN OVER TO THE OWNER ALL REMOVED ITEMS. 2.8 REPAIR AND RESTORE DESIGNATED REUSED EXISTING PRODUCTS AS REQUIRED TO MEET IN FINISHED FORM THE TYPE AND QUALJTY OF WORK IN SCOPE OF CONTRACT. 2.9 PROVIDE AND MAINTAIN CARPET MATS IN FRONT OF ALL BUILDING DOORWAYS USED BY CONSTRUCTION WORKERS FOR ACCESS SUCH AS ELEVATOR DOORWAYS, EXIT STAIR DOORWAYS, ETC. CARPET MATS SHALL BE LARGE ENOUGH TO PREVENT THE HAULING/SPREADING OF DIRT THROUGH THE BASE BUILDING PREMISES AND ELEVATOR CABS. 2.10 CONTRACTOR SHALL INSPECT, TEST AND DISCONNECT UTILITY SERVICES AT MAIN SOURCE OR MAIN BRANCH WITHOUT DISRUPTING UTIUTY SERVICES IN USE. CONTRACTOR SHALL SECURELY CAP AND/OR VALVE - OFF UTILITY SERVICE BEHIND FINAL FINISHED SURFACES OF INTENDED CONSTRUCTION OR, ONLY WHEN NOTED, AT FINISHED FACE PRIOR TO DEMOLITION OPERATIONS. UTILITY SERVICE SHALL BE DEFINED AS PLUMBING, HVAC, ELECTRICAL, AND ARE PROTECTION SYSTEMS. CONTRACTOR SHALL INDICATE PERMANENTLY ABANDONED UTILITIES ON A RECORD SEPIA TO SERVE AS PART OF THE "AS -BUILT" SET. 2.11 PROVIDE SHORING AND BRACING, OR SUPPORT TO PREVENT MOVEMENT; SETTLEMENT OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT FACILITIES OR WORK TO REMAIN. 5 METAL FABRICATIONS 5.1 PROVIDE STEEL FRAMING AND SUPPORTS FOR APPLICATIONS INDICATED OR WHICH ARE NOT A PART OF STRUCTURAL STEEL FRAMEWORK, AS REQUIRED TO COMPLETE WORK. 6 WOOD AND PLASTIC 6.1 CONCEALED ROUGH FRAMING AND BLOCKING: PROVIDE "CONSTRUCTION GRADE' LUMBER OF ANY SPECIES WITH MAXIMUM 19% MOISTURE CONTENT. 6.2 PLYWOOD BACKING PANELS: FOR MOUNTING ELECTRICAL OR TELEPHONE EQUIPMENT, PROVIDE FIRE -RETARDANT TREATED PLYWOOD PANELS, APA C -D PLUGGED INT WITH EXTERIOR GLUE, NOT LESS THAN 15/32'. 6.3 FIRE -RETARDANT TREATMENT: PRESSURE IMPREGNATE LUMBER AND PLYWOOD WITH FIRE -RETARDANT CHEMICALS TO COMPLY WITH AWPA C20 AND C27, RESPECTIVELY, AND IDENTIFY LUMBER WITH CLASSIFICATION MARKING ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. 6.4 FINISH CARPENTRY AND MILLWORK: COMPLY WITH "PREMIUM GRADE" AWI STANDARDS. .1 PROVIDE A FULL SCALE MOCK-UP FOR OWNER'S APPROVAL PRIOR TO FABRICATION OF MULTIPLE UNITS. 6.5 COUNTERS: HIGH PRESSURE DECORATIVE LAMINATE COMPLYING WITH NEMA LD 3 AND GP -50 (0.050" NOMINAL THICKNESS). .1 EDGE TREATMENT: SAME AS LAMINATE CLADDING ON HORIZONTAL SURFACES. .2 PROVIDE 2" DIAMETER PLASTIC GROMMET IN COUNTERTOP ABOVE ELECTRICAL OR DATA OUTLET LOCATIONS. 6.6 CABINETS: COMPLY WITH AWI SECTION 400 AND ITS DIVISION 4008 FOR PREMIUM GRADE NEMA LD3 LAMINATE CLAD CABINETS. .1 EXPOSED SURFACES: HORIZONTAL SURFACES OTHER THAN TOPS: GP -50 (0.050" NOMINAL THICKNESS); VERTICAL SURFACES: GP -28 (0.028" NOMINAL THICKNESS); EDGES: GP -28 (0.028" NOMINAL THICKNESS). .2 SEMI -EXPOSED SURFACES: HIGH PRESSURE LAMINATE, GP -28. .3 CABINET HARDWARE SCHEDULE: .1 HINGES: FULLY CONCEALED, SELF-CLOSING "1000 SERIES" BY GRASS OR EQUAL. .2 PULLS: WIRE PROJECTING TYPE, DRILLING 4" ON CENTER, #4483 OR EQUAL AS MANUFACTURED BY STANLEY. .3 CABINET CATCHES: ADJUSTABLE MAGNETIC CATCHES WITH MINIMUM 8 LBS. PULL; # SP 45 OR SP 46 OR EQUAL AS MANUFACTURED BY STANLEY. .4 DRAWER GLIDES: SIDE AND BOTTOM MOUNTED SLIDES WITH POSITIVE STOP AND LOCKOUT POSITION, WITH HEAVY-DUTY FULL EXTENSION; #1429 OR EQUAL AS MANUFACTURED BY KNAPE & VOGT. .5 SHELF SUPPORTS AND STANDARDS: ADJUSTABLE SHELF SUPPORTS CONSTRUCTED OF HIGH IMPACT INJECTION MOLDED NYLON AND WITH HEAVY DUTY TWIN SLOTTED SHELVING STANDARDS AS PRODUCED BY KNAPE & VOGT OR EQUAL 6.7 MILLWORK SHALL BE FABRICATED FROM FIELD MEASUREMENTS WITH PROVISIONS FOR SCRIBING AS REQUIRED TO MEET BUILT-IN CONDITIONS. 6.8 DO NOT DELIVER CASEWORK AND FINISH CARPENTRY UNTIL PAINTING, WET WORK AND SIMILAR OPERATIONS WHICH COULD DAMAGE FINISHED WORK HAS BEEN COMPLETED AND HVAC SYSTEMS HAVE BEEN PROPERLY OPERATING FOR TEN DAYS. 6.9 INSTALL CASEWORK AND FINISH CARPENTRY PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. 6.10 JOINTS BETWEEN MILLWORK DRAWERS, DOORS, ETC., TO BE OF UNIFORM WIDTH NOT TO EXCEED 1/8 U.O.N. 6.11 GROMMETS ARE TO BE FIELD CUT FOR COORDINATION WITH ELECTRICAL OUTLETS. 7 JOINT SEALERS 7.1 ONE -PART MILDEW -RESISTANT SILICONE SEALANT - AT COUNTERS AND FIXTURES: .1 "DOW CORNING 786'; DOW CORNING CORP. .2 "SCS 1702 SANITARY'; GENERAL ELECTRIC CO. .3 "863 #345 WHITE"; PECORA CORP. .4 "PROGLAZE WHITE"; TREMCO CORP. .5 "OMNIPLUS"; SONNEBORN BUILDING PRODUCTS 7.2 ACRYUC-EMULSION SEALANT - AT INTERIOR UNUKE ADJOINING SURFACES: .1 "CHEM -CALK 600'; BOSTTK CONSTRUCTION PRODUCTS DIV. .2 "AC -20'; PECORA CORP. .3 "SONOLAC"; SONNEBORN BUILDING PRODUCTS .4 "TREMCO ACRYLIC LATEX 834'; TREMCO, INC. 8 DOORS AND WINDOWS 8.1 INTERIOR DOOR FRAMES: PROVIDE BUILDING STANDARD FRAMES UNLESS NOTED OTHERWISE. COLOR TO BE SELECTED BY DESIGNER. 8.2 INTERIOR DOORS: PROVIDE BUILDING STANDARD DOORS UNLESS NOTED OTHERWISE. DOORS TO BE BUILDING STANDARD FINISH. 8.3 DOOR HARDWARE: BUILDING STANDARD WITH ADA LEVER HANDLE LATCH AND LOCKSETS. 8.4 GLASS: MEET ASTM C1036 REQUIREMENTS FOR GLASS AND ASTM C1048 REQUIREMENTS FOR HEAT -STRENGTHENED GLASS. 9 FINISHES 9.1 GYPSUM BOARD WALL FRAMING: COMPLY WITH ASTM C645. .1 INSTALL "EUMINATOR" TYPE HEAD TRACK AT WALLS TERMINATING AT CEILING. USE PREFORMED OUTSIDE CORNERS. 9.2 GYPSUM BOARD: PROVIDE 5/8' THICK REGULAR AND TYPE 'X' TAPERED EDGE GYPSUM BOARD WITH GALVANIZED STEEL TRIM ACCESSORIES AND JOINT COMPOUND COMPLYING WITH ASTM C475. FINISH IN ACCORDANCE WITH ASTM C840 TO THE HIGHEST QUALITY STANDARDS. .1 DRYWALL FINISHING: COMPLY WITH MANUFACTURER'S PRINTED INSTRUCTIONS AND SPECIFICATIONS. EXCEPTION: COMPLY WITH MORE STRINGENT REQUIREMENTS OF GYPSUM ASSOCIATION GA - 216 RECOMMENDED SPECIFICATION FOR THE APPLICATION AND FINISHING OF GYPSUM BOARD. 9.4 CEILINGS: FINISHED CEILING SHALL BE LEVEL, TRUE AND FREE FROM DAMAGED OR SOILED TILES. .1 COORDINATE PLACEMENT OF MECHANICAL AND ELECTRICAL ITEMS IN CEILING. WHERE CONFLICTS OCCUR, THE ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN. .2 CENTER CEILING ELEMENTS IN CEILING TILE, INCLUDING DOWN LIGHTS, SMOKE DETECTORS, SPRINKLER HEADS AND EXIT SIGNS UNLESS NOTED OTHERWISE. 9.5 INSTALL FLOOR FINISH TRANSITION STRIP AT CENTERLINE OF DOOR OR CASED OPENING UNLESS NOTED OTHERWISE. .1 INSTALL JOHNSONITE TRIM STRIPS AT DOOR WHERE CARPET MEETS RESILIENT TILE WITH TRIM STRIP COLOR TO MATCH CARPET. 9.6 RESILIENT FLOORING: .1 UNLESS OTHERWISE NOTED, LAY TILE FROM CENTER MARKS ESTABUSHED WITH PRINCIPAL WALLS, SO THAT TILE AT OPPOSITES EDGES OF THE ROOM ARE EQUAL WIDTH. ADJUST TO AVOID USE OF CUT WIDTHS LESS THAN 3" AT ROOM PERIMETER. .2 BASE: AT JOINTS TIGHT AND VERTICAL ON CONTINUOUS SOLID BACKING. INSTALL BASE IN LONGEST PRACTICAL LENGTHS, USING ROLL STOCK. SCRIBE TO VERTICAL OBSTRUCTIONS. 9.7 USE AN APPROVED CEMENTIIOUS FILLER TO PATCH CRACKS, SMALL HOLES AND LEVELING. ENSURE THAT FLOORS ARE LEVEL WITH MAXIMUM SURFACE VARIATION OF 9' IN 10 FEET, NON -CUMULATIVE. ti 9.8 CARPET: INSTALL CARPETING WHICH MEETS THE FOLLOWING STANDARDS: FLAMMABILITY: ASTM 2859 SURFACE BURNING: ASTM E84 SMOKE DENSITY: ASTM E662 SOUND ABSORPTION: ASTM C423 FADE RESISTANCE: AATCC 16E STATIC RESISTANCE: AATCC 134 WARRANTY. 10 YEARS .1 INSTALL BROADLOOM CARPET BY DIRECT GLUE. INDIANAPOLIS INDIANA � d1HSN/41101 h �O /,13 �a S,301AH39 AlINnvnv ds -400 E sepoo til PUBsuc�tlatnt3a ti Iia 4iIM aoueSo .1 o� 01 109(gnS NOLLX81SNoo ao� 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAiNT IS DRY, IN REINSTALL SUCH ITEMS. 12.1 CASEWORK: .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: INDIANAPOLIS INDIANA � d1HSN/41101 h �O /,13 �a S,301AH39 AlINnvnv ds -400 E sepoo til PUBsuc�tlatnt3a ti Iia 4iIM aoueSo .1 o� 01 109(gnS NOLLX81SNoo ao� 9.10 PAINT: USE PRIMER COMPATIBLE WITH SUBSTRATE. REMOVE OR 12 FURNISHINGS PROTECT HARDWARE, PLATES AND SIMILAR TRIM. AFTER PAiNT IS DRY, REINSTALL SUCH ITEMS. 12.1 CASEWORK: .1 INTERIOR PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT .1 MANUFACTURERS: PROVIDE PRODUCTS BY ONE OF THE SYSTEMS BASED ON DEVOE TO ESTABLISH QUALITY STANDARD FOLLOWING: FOR THE VARIOUS SUBSTRATES, AS INDICATED. .1 IMPERIAL CABINET CO., INC. 1. FERROUS METAL: 2 MERILLAT INDUSTRIES, INC. .3 YORKTOWNE CABINETS A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: 1. PRIMER: 1 COAT 141702 METALCLAD ACRYUC 15/16 MECHANICAL AND ELECTRICAL LATEX PRIMER. 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC SEMI -GLOSS ENAMEL 15/16.1 MECHANICAL (INCLUDING PLUMBING, ARE PROTECTION AND HVAC) AND 2. NON-FERROUS METAL: ELECTRICAL SYSTEMS ARE TO BE DESIGNED AND CONSTRUCTED BY THE A. ACRYLIC SEMI -GLOSS ENAMEL FINISH: RESPECTIVE DESIGN/BUILD CONTRACTORS OR SUBCONTRACTORS 1. PRIMER: 1 COAT 141702 METALCLAD ACRYLIC ACCORDING TO CRITERIA DEFINED BY THE TENANT AND AESTHETIC LATEX PRIMER. CRITERIA (ONLY) DEFINED BY THE ARCHITECT. THE CONTRACTOR SHALL 2. FINISH: 2 COATS #83XX MIRROLACE-WB ACRYLIC BEAR FULL RESPONSIBILITY FOR ALL DESIGN, PERFORMANCE, SEMI -GLOSS FINISH INSTALLATION AND INTER -SYSTEM COORDINATION OF MECHANICAL AND 3. FERROUS STRUCTURE: A. ACRYLIC DRY FOG FLAT FINISH: 15/16.2 ELECTRICAL SYSTEMS, GENERAL CONTRACTOR IS TO PROVIDE A COMPLETE PACKAGE OF 1. FINISH: 2 COATS #57601 UNI-GRIPWATER DESIGN/BUILD DRAWINGS FOR ARE PROTECTION, MECHANICAL, AND REDUCIBLE ACRYLIC DRY FOG COATINGG PLUMBING, SIGNED AND STAMPED FOR STATE RUNG PROCESS BY A 4. NON-FERROUS STRUCTURE: 15/16.3 CERTIFIED ENGINEER. IN CASE OF CONFLICT BETWEEN ARCHF[ECT'S AND ENGINEER'S A ACRYLIC DRY FOG FIAT FINISH: 1. FINISH: 2 COATS #57601 UNI -GRIP WATER DRAWINGS IN LOCATION OF TERMINAL MATERIALS/EQUIPMENT, SUCH AS REDUCIBLE ACRYLIC DRY FOG COATINGG.. DIFFUSERS, GRILLES, LIGHTS (IF SHOWN ON REFLECTED CEILING PLAN) 8. WOOD' AND SURFACE MOUNTED ELECTRICAL DEVICES, THE ARCHITECTURAL A ACRYLIC LATEX SEMI -GLOSS ENAMEL FINISH: DRAWINGS SHALL GOVERN. NOTIFY ARCHITECT OF DISCREPANCIES AND 1. PRIMER: 1 COAT J51701 WONDER -PRIME LATEX 15/16.4 OBTAIN WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH WORK. SUBMIT FIRE SPRINKLER PRIMER -SEALER. LAYOUT FOR COORDINATION/APPROVAL BY THE 2. FINISH: 2 COATS #83XX MIRROLAC-WB ACRYLIC OWNER OR THE OWNER'S AGENT. PATTERN OF SPRINKLER LAYOUT SEMI -GLOSS ENAMEL SHALL COORDINATE WITH PATTERN OF UGHTING LAYOUT AND SHALL B. STAIN -VARNISH RUBBED FINISH: 15/16.5 COORDINATE WITH OTHER CEIUNG COMPONENTS, DESIGN/BUILD MECHANICAL CONTRACTOR SHALL PROVIDE DRAWINGS 1. FILLER: 1 COAT #4800 WONDER WOODSTAIN PASTE WOOD FILLER (OPEN GRAIN WOODS). SHOWING THERMOSTAT LOCATION FOR REVIEW BY THE OWNER OR 2. STAIN: 1 COAT #96XX WONDER WOODSTAIN 15/16.6 OWNER'S AGENT. OUTLET/JUNCTION BOX MOUNTING HEIGHTS SHALL BE COORDINATED ALKYD STAIN. 3. SEALER: 1 COAT #4900 WONDER WOODSEALER WITH THE EQUIPMENT/APPLIANCE FOR WHICH R WAS DESIGNATED. QUICK DRY SEALER. VERIFY EQUIPMENT MOUNTING REQUIREMENTS FOR SCHEDULED 4. FINISH: 2 COATS #4600 WONDER WOODSTAIN ALKYD SATIN VARNISH. 15/16.7 EQUIPMENT. SWITCHES SHALL BE GANGED UNDER ONE PLATE. DIMMERS SHALL BE 10. GYPSUM WALLBOARD: 15/16.8 GANGED UNLESS OTHERWISE NOTED BY MANUFACTURER. DATA AND COMMUNICATION A. ACRYLIC LATEX SATIN ENAMEL FINISH: CABLES ARE PROVIDED BY OTHERS AND 1. PRIMER: 1 COAT #50801 WONDER TONES LATEX INSTALLED BY OTHERS UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PRIMER -SEALER. COORDINATE AT THE BEGINNING OF THE PROJECT WITH THE TENANT AND 2. FINISH: 2 COATS #35XX WONDER TONE ACRYLIC TENANT'S VENDORS TO DETERMINE THE PHASE DURING WHICH THE LATEX SATIN ENAMEL 13. PRECAST CONCRETE: 15/16.9 INSTALLATION SHALT OCCUR. DIMENSIONS, IF IDENTIFIED, ARE TO CENTERUNE OF OUTLET OR GANG OF A LATEX TEXTURE COATING -SAND FINISH(WrT AREAS) 15/16.10 OUTLETS, UNLESS OTHERWISE NOTED. ALL SWITCHES AND SWTTCHPLATES 1. PRIMER: 1 COAT #1502 WONDER -SHIELD ACRYLIC SHALL BE BUILDING STANDARD LATEX HOUSE PAINT PRIMER, COLOR UNLESS NOTED OTHERWISE. IF NO BUILDING STANDARD, PROVIDE 2. FINISH: 1 COAT #44101 DEQ'-VO-TEX LATEX TEXTURE COATING. 15/16.11 IVORY. WHERE FLOOR MONUMENTS ARE SHOWN NEXT TO EACH OTHER, THEY SHALL BE LOCATED AS CLOSE TOGETHER AS POSSIBLE, WHILE STILI PROVIDING PROPER ACCESS TO RECEPTACLES. 9.11 WALLCOVERING: APPLY WALLCOVERING SECURE, SMOOTH, CLE AND 15/16.12 IF ADDITIONAL OUTLETS REQUIRED, COORDINATE WITH ARCHITECTURAL FOR SPECIFIC LOCATION. WITHOUT WRINKLES, GAPS OR OVERLAPS. 15/16.13 CONTRACTOR SHALL MARK ALL POWER AND COMMUNICATION OUTLET .1 KEEP SEAMS TO A MINIMUM. HORIZONTAL SEAMS ARE NOT LOCATIONS ON SLAB AND PROVIDE ACCESS TO SITE FOR ARCHITECT TO OBSERVE PRIOR TO ANY COMMENCEMENT Of 'ROUGH -IN' ACCEPTABLE. CONSTRUCTION. .2 SEAMS MUST BE AT LEAST 2" FROM INSIDE CORNERS AND 6' FROM OUTSIDE CORNERS. GN GENERAL NOTES 10 SPECIALTIES . GN.1 CONTRACTOR TO VERIFY DIMENSIONS AND EXISTING CONDITIONS AND 10.1 FIRE EXTINGUISHERS AND CABINETS: BUILDING STANDARD, OR IF NO "AMBASSADOR' REPORT ANY DISCREPANCIES FROM THIS PLAN TO DESIGNER PRIOR TO BUILDING STANDARD, PROVIDE JL INDUSTRIES SERIES, PROCEEDING WITH CONSTRUCTION. SEMI RECESSED, DUO -PANEL, FIELD PAINTED. GN.2 DIMENSIONS ARE AS FOLLOWS, UNLESS OTHERWISE NOTED: A TO FINISHED FACE OF GYPSUM BOARD. B. TO INSIDE FACE OF JAMB AT DOORS AND OTHER OPENINGS, C. TO TOP OF FINISHED FLOORS. D. TO BOTTOM OF FINISHED CEILINGS. GN.3 SEE WALL LEGEND FOR SYMBOLS RELATED TO WALL CONSTRUCTION, EXISTING CONSTRUCTION AND WALL TYPES. GNA TERMINATE WALLS AT UNDERSIDE Of CEILING UNLESS INDICATED OTHERWISE. GN.5 DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. PARTITION LOCATIONS, DIMENSIONS AND TYPES, DOOR AND WINDOW LOCATIONS SHALL BE AS SHOWN ON CONSTRUCTION PLAN. IN CASE OF CONFLICT, NOTIFY DESIGNER FOR WRITTEN CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION. GN.6 CONTRACTOR SHALL PROVIDE CHALK LINES DELINEATING WALL LAYOUT FOR THE ARCHITECT'S OBSERVATION WITH REGARD TO DESIGN INTENT. DO NOT PROCEED WITH INSTALLATION OF STUDS WITHOUT THIS OBSERVATION. GN.7 FOR BUILT-IN WORK SURROUNDED BY PARTITION, INCLUDING BUT NOT LIMITED TO APPLIANCES AND FILES, CONTRACTOR SHALL CONFIRM THAT FLOOR SLAB DOES NOT VARY BY MORE THAN 1/4' IN 20'-0' NON- CUMULATIVE. NOTIFY DESIGNER IF TOLERANCE IS EXCEEDED. GN.8 CONTRACTOR SHALL COORDINATE PLACEMENT OF BLOCKING PRIOR TO CLOSE -IN OF WALLS. GNA SOUND INSULATED AND FIRE RATED PARTITIONING SHALL BE CAULKED AT PERIMETER WITH ACOUSTICAL OR ARE RATED SEALANT AS APPLICABLE. PLACE SEALANT BETWEEN GYPSUM BOARD AND ADJACENT SUBSTRATE. PROVIDE WITH SOUND ATTENUATING INSULATION SECURELY FASTENED TO STUD FRAMING. AT THESE PARTITIONS, BACK TO BACK ELECTRICAL JUNCTION BOXES ARE NOT PERMITTED. GN.10 ALL APPLIANCES NOTED ON ELEVATIONS SHALL BE SUPPLIED BY TENANT. N®. ARQ0910036 z ' STATE OF life �uqlot,0* 03/16/04 CSO #24062 DEMOLITION/CONSTRUCTION PLAN SCALE: 1/8" = 1'-Q" GENERAL DEMOLITION NOTES: A. REMOVE MILLWORK SHOWN DASHED. B. SAVE ALL ITEMS REMOVED FROM THE SPACE PER OWNER'S DIRECTION UNLESS NOTED OTHERWISE. C. DEMOLISH EXISTING WALL AND/OR FLOOR SURFACES BACK TO A POINT WHERE INSTALLATION OF NEW FLOORING FINISHES IS POSSIBLE. D. REMOVE EXISTING FINISHES WHERE NEW FINISHES ARE TO BE INSTALLED. REFERENCE FINISH PLAN TO COORDINATE LOCATIONS OF NEW FINISHES. GENERAL CONSTRUCTION NOTE: A. DIMENSIONS ARE FROM FACE OF FINISHED WALL TO FACE OF FINISHED WALL UNLESS NOTED OR SHOWN OTHERWISE. ANY DIMENSION NOT SHOWN OR DEEMED QUESTIONABLE ARE TO BE VERIFIED BY DESIGNER. DO NOT SCALE DRAWINGS. B. SEE CONSTRUCTION PLAN LEGEND FOR WALL CONSTRUCTION AND WALL TYPES, C. ALL WALLS SHALL BE CHALKED OFF FOR DESIGNER'S REVIEW OF NEW WALL CONSTRUCTION. D. PROVIDE CONCEALED FIRE RATED WOOD BLOCKING SUPPORTS AS REQUIRED FOR ALL SURFACE MOUNTED ITEMS. E. EXISTING DOORS AND DOOR FRAMES TO BE REUSED ARE TO BE CLEANED AND REINSTALLED AT COMPLETION OF CONSTRUCTION. CONTACT DESIGNER TO REVIEW AND APPROVE DOORS THAT ARE QUESTIONABLE FOR REUSE. F. NEW DOOR AND FRAME NUMBERS CORRESPOND TO ROOM NUMBERS. WHERE MORE THAN ONE. DOOR OCCURS IN A ROOM, A SUFFIX HAS BEEN ADDED (ie. 100A). G. ALL NEW DOORS TO BE INSTALLED WITH HINGE 6" AWAY FROM WALL UNLESS NOTED OTHERWISE. H. ALL NEW DOORS SHALL ALLOW 18" CLEAR ON PULL SIDE OF DOOR, UNLESS NOTED OTHERWISE, TO MEET CURRENT ADA CODE REGULATIONS. I. LIFESAFETY CONTRACTOR TO VERIFY NEED FOR FIRE EXTINGUISHER CABINET LOCATIONS. FIRE EXTINGUISHER CABINETS WILL BE PROVIDED BY TENANT IF REQUIRED, LOCATIONS MUST BE SUBMITTED TO CSO INTERIORS FOR REVIEW FOR AESTHETICS PURPOSES ONLY. J. RADIUS ALL OUTSIDE CORNERS OF COUNTER TOPS. SIZE OF RADIUS TO BE VERIFIED WITH DESIGNER. K. APPLY SEALANT AT ALL PLUMBING FIXTURES AT JUNCTURE WITH WALL AND AT ALL COUNTERTOPS AND BACKSPLASH JUNCTURES. L. BUILDING OWNER AND/OR G.C. TO PROVIDE MINIBLINDS AT ALL PERIMETER WINDOWS. EXISTING MINIBLINDS TO BE RELOCATED ARE TO BE STORED DURING CONSTRUCTION PHASE, THEN CLEANED AND REINSTALL UPON COMPLETION OF CONSTRUCTION. M. FLOOR SHALL BE CLEANED, SMOOTH AND LEVEL FOR INSTALLATION OF NEW FLOOR FINISHES AS SCHEDULED. N. ALL WALLS SCHEDULED TO REMAIN (I.E. CORE WALLS, AND DEMISING WALLS) SHALL BE PATCHED, REPAIRED, AND SANDED SMOOTH IN PREPARATION FOR NEW FINISHES. PLAN NOTES: FPt ALIGN FINISHED FACES. fP2 CENTER WALL ON WINDOW MULLIONS AS PER BUILDING STANDARD DETAILS. USE SEALANT AT MULLIONS FOR SOUND INSULATION. VERIFY DIMENSION FROM MULLION TO MULLION AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. REFERENCE DETAIL 2/A201. 8 NEW OR RELOCATED RECESSED FIRE EXTINGUISHER CABINET TO BE INSTALLED IN WALL AT THIS LOCATION WITH TOP OF CABINET AT 54" AFF. PAINT TO MATCH ADJACENT WALL SURFACE. FIRE EXTINGUISHER CABINET TO MATCH BUILDING STANDARD, UNLESS NOTED OTHERWISE. FP4 MILLWORK & SINK TO BE MOVED TO NEW LOCATION IN BREAK ROOM 503. CAP PLUMBING BEYOND FINISHED SURFACE. PREP SURFACES FOR NEW FINISHES. 8 RELOCATED SINK & MILLWORK: INSTALL NEW PLASTIC LAMINATE TOP (PL1.) tis REPLACE EXISTING PHONE BOARD WITH NEW 3/4" x 8' x 4' FIRE RETARDANT PLYWOOD PHONE BOARD. PHONE BOARD TO BE PAINTED WITH FIRE RETARDANT PAINT, COLOR OF PAINT TO MATCH ADJACENT WALL FINISH. 8 EXISTING MILLWORK TO REMAIN. S DRYWALL HEADER © DOOR HEIGHT. LEGEND — — — — TO BE DEMOLISHED. EXISTING PARTITION TO REMAIN ALL WALLS TO BE W1 UNLESS OTHERWISE NOTED W1= NEW BUILDING STANDARD WALL CONSTRUCTION TO BE: 2-1/2" METAL STUDS @ 16" O.C. WITH 1/2" GYPSUM BOARD EACH SIDE. WALLS TO EXTEND TO UNDERSIDE OF CEILING LINE. W2= NEW WALL CONSTRUCTION TO MATCH ADJACENT (N WALL CONSTRUCTION �y OUTLET TO BE REMOVED Lb SYSTEMS FURNITURE BASE POWER FEED TO BE REMOVED DENOTES RELOCATED MILLWORK. o NEW DOOR AND FRAME. REFER TO DOOR SCHEDULE. EXISTING DOOR AND FRAME TO REMAIN. W DOOR SCHEDULE C1 CARPET - DIRECT GLUE DOOR FRAME Landscape Architecture HARDWARE REMARKS SIZE C2 CARPET - DIRECT GLUE MFG: J&J N o STYLE: TEXTURES COLOR: 8409 MULCH VCT1 w Q J z o� z W J = tzic' �o>- Mm Y N (n COLOR: 51868 SMOKEY BROWN BASE B1 VINYL BASE -4" COVE U' z m Z _ Q it Q Q —1 Q Q Q m U o to p o o a _ v a Q -03(n a- u u u un= u u FAM. Z O z o Of � — = F— -j w :;E w = cn U m -l(n�UC�O O o 506 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 L,S 507 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 L,S ca 509 OFFICE 3'-0" 8'-0" 1 3/4" WOOD D1 HM D1 L,S 510 OFFICE 3'-0" 6'-8" 1 3/4" WOOD D1 HM D1 L,S 515 COPY ROOM 3'-0" 6'-8" 1 3/4" WOOD D1 HM D1 PS,S W TYPICAL WALL TYPE PREFINISHED ALUMINUM RECEIVER TRIM "GB350"-FASTEN AT WINDOW SILL & SET IN A CONTINUOUS BEAD OF ACOUSTICAL SEALANT. TRIM COLOR TO MATCH BLDG. WINDOW MULIONS METAL STUD —`" CONTINUOUS BEAD OF ACOUSTICAL SEALANT WINDOW MULLION DETAIL SCALE: NTS DOOR SCHEDULE NOTES 1. ALL DOORS ARE TO BE RELOCATED FROM THE EXISTING SPACE AND TOUCHED UP TO MATCH EXISTING STAIN. NEW DOORS TO MATCH BUILDING STANDARD STAIN. 2. PROVIDE NEW MEDIUM GRADE LEVER HARDWARE TO MATCH BUILDING STANDARD WHERE NEEDED. 3. CONTRACTOR TO VERIFY DOOR HEIGHT PRIOR TO CONSTRUCTION. 4. COORDINATE KEYING LOCKSETS WITH TENANT. 5. ALL DOOR FRAMES ARE TO BE BUILDING STANDARD. 6. EXISTING DOORS #502, #504, #511, #512, #513 ARE TO HAVE LOCKSETS. ADA COMPLIANT LEVER HARDWARE DOOR/FRAME ELEVATIONS SCALE: 1/4" = 1'-0" sit DRAIN TYPICAL PLUMBING ISOMETRIC A201 j SCALE: NTS 1 /2"HW, 1/2"m & 1-1/4"V :T TO G MAINS _DING FINISH PLAN SCALE: 1/8" = 1'-0" GENERAL FINISH NOTES: A. ALL EXISTING FINISHES TO REMAIN ARE TO BE CLEANED AND RESTORED TO AS CLOSE AS POSSIBLE TO THEIR ORIGINAL CONDITION. B. ALL NEW DOOR FRAMES TO BE FINISHED TO MATCH EXISTING. C. G.C. TO SUBMIT SEAMING DIAGRAMS OF ALL NEW CARPET IN PROJECT SCOPE FOR REVIEW AND APPROVAL BY DESIGNER BEFORE PROCEEDING WITH FLOORING INSTALLATION. D. ALTERNATES WILL NOT BE ACCEPTED WITHOUT WRITTEN APPROVAL OF DESIGNER, SAMPLES, WHEN APPLICABLE, SHALL BE SUBMITTED FOR REVIEW. F. REFERENCE INTERIOR ELEVATIONS, WHERE PROVIDED, FOR ADDITIONAL FINISH INFORMATION. G. PAINT NEW OR EXISTING PLYWOOD PHONE BOARD/S WITH FIRE RETARDANT PAINT. COLOR TO MATCH ADJACENT WALL FINISH. H. PAINT ALL EXPOSED METAL SURFACES i.e.. GRILLS, HEATERS, AND FIRE EXTINGUISHER CABINETS) TO MATCH ADJACENT SURFA E. I. VERIFY THAT M;NIBLINDS ARE PROVIDED AT ALL PERIMETER WINDOW LOCATIONS. IF NEW MINIBLINDS ARE REQUIRED, MINIBLINDS ARE TO MATCH BUILDING STANDARD. FINISH PLAN NOTES: 8 INSTALL NEW PLASTIC LAMINATE TOP (PL1) ON RELOCATED MILLWORK. FINISH LEGEND: FLOORCOVERINGS C1 CARPET - DIRECT GLUE Engineering MFG: J&J Landscape Architecture STYLE: DECIBEL Corporate Office COLOR: 8507 THUNDER C2 CARPET - DIRECT GLUE MFG: J&J 0 STYLE: TEXTURES COLOR: 8409 MULCH VCT1 VINYL COMPOSITION TILE m MFG: ARMSTRONG o� PATTERN: STANDARD EXCELON o o COLOR: 51868 SMOKEY BROWN BASE B1 VINYL BASE -4" COVE MANUFACTURER: VPI COLOR: 54 BURNT UMBER PAINT THROUGHOUT MFG: ICI P1 COLOR: 637 FOSSIL GREY FINISH: EGGSHELL PLASTIC LAMINATE PI.1 MANUFACTURER: WILSONART COLOR: 4674-60 EVENING TIGRIS FINISH: MATTE Ue REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 ■ CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574.0957 ®Copyright 2001 0 Of 0 0 m mU' o� co �co op o o -,.< L) C/) o z Q J a FAM. Z J � J Old w 0 z Q z O o ■.J 0 O o z CL O 00— L0 cn z O Z Q � C a�Q = J W Q Z LU o O z ca L■ Z O Q z O J O 2 W Cert;®®r����r«�rr®i TUqr �..Q� fid•. m No. AR00910036 Z STATE OF Drawing Number: A201 Of Sheets Duke Job Number: A/E Job Number: 24062C L Ue REALTY CORPORATION 600 East 96th Street Suite 100 Indianapolis, IN 46240 Phone: (317) 808-6000 Fax: (317) 808-6797 L ! t stj CSO Architecture Engineering Interiors Landscape Architecture Land Surveying Corporate Office 280 East 96th Street, Suite 200 Indianapolis, Indiana 46240 317.848.7800 FAX 317.574. 0957 Vopyright 2001 c O N � O r 11 m m M m A V7� OO O LJ U C z a J a a a v J J a J V w N Z Z O Q 0 J 30z W 0 je L0 ' ^� v / cc = Lj aPo z 0 a�C V)Z J Z J Q a W O z U, Z 1 'Q W V O W F— C.� W J LL W cc Cert;e��c�liooeo�i jU�+ f" ;5i�i 14Ilk No. AR00910036 t i✓✓ •STAQ ACOP�: ✓ � e�� 'G� • O y Drawing Number: A202 Of Sheets Duke Job Number: A/E Job Number: 24062C