WALL TYPE NOTES Fidelity Keystone Tower 650 E. Carmel Drive Carmel, IN 46032 STATE SUBMITTAL SET UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLANS ALL WALLS TO BE WALL TYPE # 1. NOTE; REFER TO ROOM FINISH SCHEDULE FOR WALL BASE TYPES AS WELL AS CEILING TYPES AND CEILING HEIGHTS. NOTE; PROVIDE CONTROL JOINTS IN ALL METAL STUD/ GYP BOARD WALLS AT 30'-0" MAXIMUM SPACING. AT RATED WALLS STUFF CONTROL JOINT FULL WITH SOUND ATTENUATION FIRE BLANKET. COORDINATE LOCATIONS OF CONTROL JOINTS WITH ARCHITECT PRIOR TO PLACEMENT. REFER TO FLOOR PLANS FOR LOCATION OF EACH INDIVIDUAL WALL TYPE. AT RATED WALL; FOLLOW MANUFACTURERS PREVIOUSLY TESTED ASSEMBLY CONSTRUCTION TECHNIQUES AS NOTED. COORDINATE WITH MANU FOR ADDITIONAL INFORMATION. ASSEMBLY NUMBER AS TESTED IS 'SWRI PROJECT NO. 01-2602-620' FOR ELIMINATOR TRACK ASSEMBLY ONLY. 3-2-04 NEW DOOR FRAME. REFER TO DOOR FINISH SCHEDULE FOR TYPE OR USE BUILDING OWNER STANDARDS. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. NEW DOOR FRAME. REFER TO DOOR FINISH SCHEDULE FOR TYPE OR USE BUILDING OWNER STANDARDS. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. NOTE; UNLESS OTHERWISE NOTED OR DIMENSIONED ON PLANS PROVIDE 4' OF SPACE AT HINGE SIDE OF ALL DOOR FRAMES. 1 MATCH NEW WALL TYPE WITH EXISTING WALL CONSTRUCTION TO REMAIN. EXISTING COLUMN WITH WRAP, UNLESS OTHERWISE NOTEI ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE ADJACENT COLUMN WRAP SITE MGP NOSCALE PROTECTED FROM DAMAGE OF ANY KIND THE CONTRACTOR SHALL BE RESPONS43LE FOR FIELD VERIFYING ALL EXISTING WORK WHICH IS TO REMAIN, AND DETERMINING WHETHER OR NOT IT CAN BE REPAIRED AND/OR RECONDITIONED TO MATCH AND BLEND WITH NEW MATERIALS AND COMPONENTS. HE SHALL OBTAIN THE OWNER'S APPROVAL OF THE SCOPE AND LIMIT OF SAID WORK PRIOR TO STARTING CONSTRUCTION. NO CHANGE ORDERS SHALL BE ACCEPTED FOR COMPLETED WORK THAT DOES NOT CONFORM TO THE STANDARDS ESTABLISHED AT THE TIME OF BID ACCEPTANCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT SCOPE OF WORK, BUILDING STANDARDS, SCHEDULE AND DEADLINES. THE CONTRACTOR SHALL FURTHER BE RESPONSIBLE FOR ADVISING THE OWNER OF ALL LONG LEAD TIME ITEMS AFFECTING THE PROJECT SCHEDULE AND SHALL, UPON REQUEST FROM THE OWNER, SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES FOR SUCH LONG LEAD TIME ITEMS TO THE OWNER. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER ACCESS TO THE SPACE AND THE ONGOING CONSTRUCTION WORK. DISRUPTIVE OR POTENTIALLY HAZARDOUS CONSTRUCTION ACTIVITIES SHALL BE COORDINATED TO OCCUR AFTER NORMAL OFFICE HOURS, SO AS TO MINIMIZE DISTURBANCE TO BUILDING OCCUPANTS. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER FOR DELIVERY TO THE SPACE OF ALL BUILDING MATERIALS, AND SCOPE NOTES W/ MORE STRINGENT. ANY MISCELLANEOUS ' CONTRACTOR=S ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER WB BE FURNISHED AND RESPONSIBILITIES ABOVE FINISHED FLOOR INSTAL EDOBYSHALL THE CONTRACTOR(S) FLOOR DRAIN RE: ALL SHEETS ALL WORK SHALL BE WARRANTED OUTSIDE DIAMETER SATISFACTORY, IN MATERIALS AND ACT SHOULD THERE BE ANY QUESTIONS WORKMANSHIP, FOR A MINIMUM PERIOD FIN REGARDING THE CONTRACT DOCUMENTS, OF ONE (1) YEAR, OR FOR THE PERIOD OF OPNG EXISTING CONDITIONS, AND/OR DESIGN WARRANTY CUSTOMARY, OR STIPULATED FOR, ", ROOM NAME, SIZE AND NUMBER. REFER INTENT, THE CON RACTOR SHALL BE THE TRADE, CRAFT, OR PRODUCT, WHICHEVER APPROXIMATE RESPONSIBLE FOR OBTAINING A IS LONGER. THEREFORE, ONLY COMPETENT FLOOR CLARIFICATION FROM THE ARCHITECT PRIOR TO MECHANICS CAPABLE OF PRODUCING GOOD OPPOSITE BID SUBMITTAL AND PROCEEDING WITH WORKMANSHIP CUSTOMARY TO THE TRADE AWT ANY WORK, OR RELATED WORK, IN SHOULD BE USED. COMMENCING WORK FT QUESTION. BY A CONTRACTOR OR SUBCONTRACTOR O.H. CONSTITUTES ACCEPTANCE OF THE pcn THESE CONTRACT DOCUMENTS ARE CONDITIONS AND SURFACE CONCERNED. IF BLOCKING INTENDED TO DESCRIBE ONLY THE SCOPE ANY SUCH CONDITIONS ARE UNACCEPTABLE, FLOOR DRAIN AND APPEARANCE OF THE REAL PROPERTY THE GENERAL CONTRACTOR SHOULD BE OUT TO OUT IMPROVEMENTS, INCLUDING THE NOTIFIED AT ONCE AND NO WORK DONE B.O. PERFORMANCE AND LEVEL OF QUALITY UNTIL CONDITIONS ARE ACCEPTABLE. FE EXPECTED OF ITS COMPONENTS. IT IS PL LAM INCUMBENT UPON THE CONTRACTOR TO THE CONTRACTOR SHALL COORDINATE WITH ELEVATION TARGET INSURE THAT ALL WORK COMPLETED AND THE OWNER, OR THEIR AUTHORIZED AGENT, BOTTOM MATERIALS INSTALLED BE IN FULL TO DETERMINE ALL EXISTING MATERIALS TO FIRE EXTINGUISHER CABINET COMPLIANCE, AS A MINIMUM STANDARD, BE SALVAGED AND RETAINED BY THE PLYWOOD WITH ALL APPLICABLE CODES, REGULATIONS OWNER. THE CONTRACTOR SHALL REMOVE CAB AND ORDINANCES HAVING JURISDICTION. SALVAGEABLE MATERIALS FROM THE SPACE GA AND STORE IN A LOCATION AS DIRECTED BY PS THESE CONTRACT DOCUMENTS DO NOT THE OWNER. ALL OTHER MATERIALS , ATTEMPT TO INSTRUCT THE CONTRACTOR IN RUBBISH, AND DEBRIS, SHALL BE REMOVED CARPET THE DETAILS OF HIS TRADE. THEY ARE AND PROMPTLY DISPOSED OF BY THE GRAB BAR PERFORMANCE SPECIFICATIONS IN THAT THEY CONTRACTOR AT AN OFFSITE LOCATION. THE QUARRY TILE DO REQUIRE THAT ALL MANUFACTURED CONTRACTOR SHALL TAKE ALL NECESSARY CJ ITEMS, MATERIALS,XND EQUIPMENT BE PRECAUTIONS TO ASSURE THAT ALL PROPERTY GWB INSTALLED IN STRICT ACCORDANCE WITH THE IMPROVEMENTS [I.E., PARTITIONS, DOORS, R MANUFACTURER'S RECOMMENDED FRAMES, CABINETS, CEILING GRID, CEILING SPECIFICATIONS, EXCEPT IN THE CASE TILE, AND THE ELECTRICAL AND MECHANICAL WHERE THE CONTRACT DOCUMENTS ARE CENTER LINE DEVICES, ETC.] WHICH ARE TO REMAIN, ARE MATCH NEW WALL TYPE WITH EXISTING WALL CONSTRUCTION TO REMAIN. EXISTING COLUMN WITH WRAP, UNLESS OTHERWISE NOTEI ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE ADJACENT COLUMN WRAP SITE MGP NOSCALE PROTECTED FROM DAMAGE OF ANY KIND THE CONTRACTOR SHALL BE RESPONS43LE FOR FIELD VERIFYING ALL EXISTING WORK WHICH IS TO REMAIN, AND DETERMINING WHETHER OR NOT IT CAN BE REPAIRED AND/OR RECONDITIONED TO MATCH AND BLEND WITH NEW MATERIALS AND COMPONENTS. HE SHALL OBTAIN THE OWNER'S APPROVAL OF THE SCOPE AND LIMIT OF SAID WORK PRIOR TO STARTING CONSTRUCTION. NO CHANGE ORDERS SHALL BE ACCEPTED FOR COMPLETED WORK THAT DOES NOT CONFORM TO THE STANDARDS ESTABLISHED AT THE TIME OF BID ACCEPTANCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT SCOPE OF WORK, BUILDING STANDARDS, SCHEDULE AND DEADLINES. THE CONTRACTOR SHALL FURTHER BE RESPONSIBLE FOR ADVISING THE OWNER OF ALL LONG LEAD TIME ITEMS AFFECTING THE PROJECT SCHEDULE AND SHALL, UPON REQUEST FROM THE OWNER, SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES FOR SUCH LONG LEAD TIME ITEMS TO THE OWNER. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER ACCESS TO THE SPACE AND THE ONGOING CONSTRUCTION WORK. DISRUPTIVE OR POTENTIALLY HAZARDOUS CONSTRUCTION ACTIVITIES SHALL BE COORDINATED TO OCCUR AFTER NORMAL OFFICE HOURS, SO AS TO MINIMIZE DISTURBANCE TO BUILDING OCCUPANTS. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER FOR DELIVERY TO THE SPACE OF ALL BUILDING MATERIALS, AND TYPICAL WALL ALIGNMENT PLAN f ANY EXISTING CONSTRUCTION (WALL, COLUMN WRAP, ETC) TO REMAIN. UNLESS OTHERWISE NOTED OR DIMENSIONED ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE OF ADJACENT EXISTING CONSTRUCTION TO REMAIN. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. ANY EXISTING CONSTRUCTION (WALL, COLUMN WRAP, ETC) TO REMAIN. UNLESS OTHERWISE NOTED OR DIMENSIONED ALIGN FACE OF ANY NEW CONSTRUCTION 1,11TH FACE OF ADJACENT EXISTING CONSTRUCTION TO REMAIN. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. 113 NO SCALE TYPICAL DETAILS WALL TYPE #Z 1 NO SCALE SHALL ARRANGE FOR USAGE OF THE FREIGHT ELEVATOR [OR SUCH ELEVATOR DESIGNATED]. IF DELIVERY OF BUILDING MATERIALS INVOLVES THE USE OF FACILITIES OTHER THEN THE AVAILABLE ELEVATORS, THE CONTRACTOR SHALL COORDINATE SUCH ACTIVITIES IN SUCH A MANNER WHICH POSES NO HAZARD TO ANY PERSONNEL WITHIN OR AROUND THE BUILDING OR BUILDING SITE. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING, ACCOMPANIED BY THE ALTERNATIVE PRODUCT INFORMATION, TO THE ARCHITECT. ALL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT, NO LATER THAN (10) WORKING DAYS PRIOR TO BID OPENING DATE. SUBSTITUTIONS SHALL ONLY BE CONSIDERED ONLY IF THEY DO NOT SACRIFICE QUALITY, APPEARANCE, AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE OWNER BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR SCALE THE DRAWINGS TO DETERMINE THE DIMENSIONS. SEE FLOOR PLAN FOR DIMENSION LOCATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL SELECTED MATERIALS WHICH SHALL BE COMPLETE IN ALL RESPECTS PRIOR TO THE FINAL ACCEPTANCE, UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PRESERVE ALL PRINTED INSTRUCTIONS AND WARRANTIES THAT ARE PROVIDED WITH EQUIPMENT OR MATERIALS USED, AND DELIVER SAID f PRINTED MATTER TO THE OWNER AT THE TIME OF SUBSTANTIAL COMPLETION. THE CONTRACTOR SHALL INSTRUCT THE OWNER OR OWNER'S REPRESENTATIVE IN THE PROPER PROPER USE OF THE EQUIPMENT FURNISHED BY THEIR TRADE. GENERAL CONTRACTOR IS TO PROVIDE A THOROUGH CONSTRUCTION CLEAN-UP AT CLOSE-OUT, INCLUDING VACUUMING AND CLEANING ALL CARPETING. DESIGN COMPLIANCE REVIEW RE: ALL SHEETS THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF CUSTOM MILLWORK, CUSTOM FABRICATION OR MANUFACTURE, AND PHYSICAL SAMPLES OF ALL FINISH MATERIALS SPECIFIED TO THE ARCHITECT FOR REVIEW AND APPROVAL BY THE OWNER. REVIEWED SHOP DRAWINGS AND SCHEDULES PREPARED BY OTHERS SHALL NOT BE CONSTRUED TO BE PART OF THE CONTRACT DOCUMENTS, AS THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR DRAWINGS, SCHEDULES AND/OR SPECIFICATIONS FOR WORK ON THE PROJECT PREPARED OR ACCOMPLISHED BY OTHERS. THE ARCHITECT WILL REVIEW THE DRAWINGS AND SAMPLES FOR CONFORMITY WITH THE INFORMATION CONTAINED IN THE CONSTRUCTION DOCUMENTS, AND RETURN THE SUBMITTALS TO THE CONTRACTOR WITHIN FIVE (5) WORKING DAYS OF RECEIPT, EXCEPT AS MAY OTHERWISE BE PROVIDED FOR BY THE OWNER. METROPOLITAN INDIANAPOLIS VICINITY MAP NOSCALE UON UNLESS OTHERWISE NOTED UR URINAL VCT VINYL COMPOSITION TILE VERT VERTICAL VT VINYL TILE W. WIDE/WIDTH W/ WITH ABBREVIATIONS WITHOUT WB A.F.F. ABOVE FINISHED FLOOR FD FLOOR DRAIN OD OUTSIDE DIAMETER WATER HEATER ACT ACOUSTICAL CEILING TILE FIN FINISH OPNG OPENING ROOM NAME, SIZE AND NUMBER. REFER APP APPROXIMATE FLR FLOOR OPP OPPOSITE Y AWT ACOUSTICAL WALL TREATMENT FT FEET O.H. OPPOSITE HAND pcn BLKG BLOCKING FD FLOOR DRAIN 0 TO 0 OUT TO OUT Xxx B.O. BOTTOM OF FE FIRE EXTINGUISHER PL LAM PLASTIC LAMINATE ELEVATION TARGET BOT BOTTOM FEC FIRE EXTINGUISHER CABINET PLWD PLYWOOD CAB CABINET GA GAUGE PS PROJECTION SCREEN CAR CARPET GB GRAB BAR QT QUARRY TILE CJ CONTROL JOINT GWB GYPSUM WALLBOARD R RISER CL CENTER LINE HDWR HARDWARE RA RETURN AIR CMU CONCRETE MASONRY UNIT H. HIGH/HEIGHT RB RESILIENT BASE COL COLUMN HM HOLLOW METAL REF CONC CONCRETE HORIZ HORIZONTAL REFERENCE CONST CONSTRUCTION HVAC HEATING, VENTILATING, AIR COND. REFR READ REFRIGERATOR REQUIRED CONT CONTINUOUS HW HOT WATER RID ROUGH OPENING CT CERAMIC TIE JST JOIST CW COLD WATER JT JOINT SA SUPPLY AIR DP DEEP/DEPTH KIT KITCHEN SCHED SCHEDULE DET DETAIL SEC SECTION DF DRINKING FOUNTAIN LAM LAMINATE SIM SIMILAR DIM DIMENSION LAV LAVATORY SPECS SPECIFICATIONS DWG DRAWING LLH LONG LEG HORIZONTAL SF SQUARE FOOT DWC DRINKING WATER COOLER LLV LONG LEG VERTICAL SA SUPPLY AIR EA EACH MAS MASONRY SS STAINLESS STEEL EJ EXPANSION JOINT MAX MAXIMUM STD STANDARD EL ELEVATION MB MARKER BOARD STL STEEL EIFS EXTERIOR INSULATION FINISH SYSTEM MECH MECHANICAL SUSP SUSPENDED E.T.R. EXISTING TO REMAIN MEZZ MEZZANINE TB TACK BOARD EXIS EXISTING MFG MANUFACTURER TEL TELEPHONE EXP EXPANSION MIN MINIMUM T.O. TOP EXT EXTERIOR M.O. MASONRY OPENING OF TV TELEVISION N.I.C. NOT IN CONTRACT TYP TYPICAL TYPICAL WALL ALIGNMENT PLAN f ANY EXISTING CONSTRUCTION (WALL, COLUMN WRAP, ETC) TO REMAIN. UNLESS OTHERWISE NOTED OR DIMENSIONED ALIGN FACE OF ANY NEW CONSTRUCTION WITH FACE OF ADJACENT EXISTING CONSTRUCTION TO REMAIN. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. ANY EXISTING CONSTRUCTION (WALL, COLUMN WRAP, ETC) TO REMAIN. UNLESS OTHERWISE NOTED OR DIMENSIONED ALIGN FACE OF ANY NEW CONSTRUCTION 1,11TH FACE OF ADJACENT EXISTING CONSTRUCTION TO REMAIN. NEW INTERIOR WALL CONSTRUCTION. REFER TO FLOOR PLANS FOR TYPE. 113 NO SCALE TYPICAL DETAILS WALL TYPE #Z 1 NO SCALE SHALL ARRANGE FOR USAGE OF THE FREIGHT ELEVATOR [OR SUCH ELEVATOR DESIGNATED]. IF DELIVERY OF BUILDING MATERIALS INVOLVES THE USE OF FACILITIES OTHER THEN THE AVAILABLE ELEVATORS, THE CONTRACTOR SHALL COORDINATE SUCH ACTIVITIES IN SUCH A MANNER WHICH POSES NO HAZARD TO ANY PERSONNEL WITHIN OR AROUND THE BUILDING OR BUILDING SITE. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING, ACCOMPANIED BY THE ALTERNATIVE PRODUCT INFORMATION, TO THE ARCHITECT. ALL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT, NO LATER THAN (10) WORKING DAYS PRIOR TO BID OPENING DATE. SUBSTITUTIONS SHALL ONLY BE CONSIDERED ONLY IF THEY DO NOT SACRIFICE QUALITY, APPEARANCE, AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE OWNER BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT OF EQUAL QUALITY TO THE PRODUCT SPECIFIED. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR SCALE THE DRAWINGS TO DETERMINE THE DIMENSIONS. SEE FLOOR PLAN FOR DIMENSION LOCATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL SELECTED MATERIALS WHICH SHALL BE COMPLETE IN ALL RESPECTS PRIOR TO THE FINAL ACCEPTANCE, UNLESS OTHERWISE NOTED. THE CONTRACTOR SHALL PRESERVE ALL PRINTED INSTRUCTIONS AND WARRANTIES THAT ARE PROVIDED WITH EQUIPMENT OR MATERIALS USED, AND DELIVER SAID f PRINTED MATTER TO THE OWNER AT THE TIME OF SUBSTANTIAL COMPLETION. THE CONTRACTOR SHALL INSTRUCT THE OWNER OR OWNER'S REPRESENTATIVE IN THE PROPER PROPER USE OF THE EQUIPMENT FURNISHED BY THEIR TRADE. GENERAL CONTRACTOR IS TO PROVIDE A THOROUGH CONSTRUCTION CLEAN-UP AT CLOSE-OUT, INCLUDING VACUUMING AND CLEANING ALL CARPETING. DESIGN COMPLIANCE REVIEW RE: ALL SHEETS THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF CUSTOM MILLWORK, CUSTOM FABRICATION OR MANUFACTURE, AND PHYSICAL SAMPLES OF ALL FINISH MATERIALS SPECIFIED TO THE ARCHITECT FOR REVIEW AND APPROVAL BY THE OWNER. REVIEWED SHOP DRAWINGS AND SCHEDULES PREPARED BY OTHERS SHALL NOT BE CONSTRUED TO BE PART OF THE CONTRACT DOCUMENTS, AS THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR DRAWINGS, SCHEDULES AND/OR SPECIFICATIONS FOR WORK ON THE PROJECT PREPARED OR ACCOMPLISHED BY OTHERS. THE ARCHITECT WILL REVIEW THE DRAWINGS AND SAMPLES FOR CONFORMITY WITH THE INFORMATION CONTAINED IN THE CONSTRUCTION DOCUMENTS, AND RETURN THE SUBMITTALS TO THE CONTRACTOR WITHIN FIVE (5) WORKING DAYS OF RECEIPT, EXCEPT AS MAY OTHERWISE BE PROVIDED FOR BY THE OWNER. METROPOLITAN INDIANAPOLIS VICINITY MAP NOSCALE UON UNLESS OTHERWISE NOTED UR URINAL VCT VINYL COMPOSITION TILE VERT VERTICAL VT VINYL TILE W. WIDE/WIDTH W/ WITH W/O WITHOUT WB WOOD BASE WC WATER CLOSET WD WOOD WH WATER HEATER WP WORKING POINT NORTH ;USPENDED ACOUSTICAL CEILING TILE. ?E: ROOM FIN. SCHED. FOR INFO. :HICAGO METALLIC ELIMINATOR 'RACK. BUILT IN TRIM EDGE W/ 3/4" 'ROTECTIVE TAPE. FLAT TAPE ONLY. ;PACKE AND SAND. -ILL WALL SOLID WITH SOUND ATTENUATION 3ATTS INSULATION IN THICKNESS TO MATCH REQUIRED METAL STUD SIZE. 1-5/8' METAL STUDS AT 6" O.C. WITH 5/8' GYPSUM BOARD ACH SIDE. 'LOOR UNE EXISTING CONDITIONS CHANGE ORDERS RE: ALL SHEETS EXISTING CONDITIONS SHOWN ON THESE DRAWINGS ARE BASED UPON BASE BUILDING OR OTHER CONSTRUCTION DOCUMENTS MADE AVAILABLE TO THE ARCHITECT BY THE BUILDING OWNER. UNLESS OTHERWISE NOTED, AS -BUILT ARCHITECTURAL CONDITIONS HAVE NOT BEEN FIELD VERIFIED AND MAY VARY FROM THOSE SHOWN. PRIOR TO SUBMITTING THE CONSTRUCTION BID, THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS AND ANY CRITICAL DIMENSIONS ASSOCIATED WITH THE PROPOSED WORK. THE CONTRACTOR SHALL CONFIRM THAT ALL WORK OUTLINED WITHIN THESE DOCUMENTS MAY BE ACCOMPLISHED AS SHOWN, PRIOR TO THE COMPLETION OF THE BIDDING PROCESS, AND SHALL NOTIFY BOTH THE ARCHITECT AND THE BUILDING OWNER OF ANY CONDITIONS ENCOUNTERED WHICH MAY EFFECT BUILDING CODE COMPLIANCE. LIFE SAFETY AND ISSUANCE OF A CERTIFICATE OF OCCUPANCY, THE TIMELY COMPLETION FOR THE PROJECT OR ESTABLISHED BUDGET OF SUCH WORK. NO ADDITIONAL FUNDS WILL BE APPROVED FOR WORK OMITTED FROM THE CONSTRUCTION BID DUE TO LACK OF VERIFICATION BY THE CONTRACTOR, EXCEPT AS OTHERWISE APPROVED BY THE OWNER FOR WORK ASSOCIATED WITH "HIDDEN" CONDITIONS NOT ACCESSIBLE PRIOR TO CONSTRUCTION. DOCUMENT APPROVAL CLIENT/TENANT DATE TITLE PROPERTY MANAGER DATE CARSON DESIGN ASSOCIATES DATE UPON EXECUTION, THE CLIENT AND PROPERTY MANAGER APPROVE ALL ASPECTS OF THE SCOPE OF WORK SHOWN IN THESE DOCUMENTS, INCLUDING DESIGN CONTENT, SCOPE OF CONSTRUCTION AND FINISH SELECTION FOR THE FOLLOWING PHASE: F1 SPACE PLANNING oPRELIMINARY PRICING F1 CONSTRUCTION DOCUMENTATION ALL COSTS INCURRED DUE TO MISINTERPRETATION OF THESE DOCUMENTS OR ANY CHANGES TO THE PROJECT REQUESTED AFTER SIGN -OFF SHALL NOT BE THE RESPONSIBILITY OF CARSON DESIGN ASSOCIATES AND SHALL BE Tur c(" E RESPONSIBILITY OF THE CLIENT. SHEET INDE DRWG Al DEMOLITION & CONSTRUCTION PLANS DRWG A2 REFLECTED CEILING & ELECTRICAL LOCATION DRWG A3 FINISH PLAN WALL LEGEND EXISTING PARTIPONS TO REMAIN. EXISTING PARTITNS TO BE REMOVED. SEE EMO DRAWING. NEW PARTITIONS TO BE CONSTRUCTED DESIGNATES INTERIOR WALL CONST, X TYPES. REFER TO FLOOR[ANS FOR LOCATIONS. REFER TO W TYPES ON THIS SHEET FOR ACTUAL F1L CONSTRUCTION WALL TYPE #1 NOTE: ALL WALLS ARE W1 UNLESS OTHERWISE NOTED. SUSPENDED ACOUSTICAL CER ING TILE. RE: ROOM FIN. SCHED. FOR INFO. CHICAGO METALLIC ELIMINATCR TRACK. BUILT IN TRIM EDGE W/ 3/4' PROTECTIVE TAPE. FLAT TAPE ONLY. SPACKLE AND SAND. 3-5/8" METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. FLOOR LINE 1A NO SCALE L G C� ^ CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.843.5975 11590 N. MERIDIAN SUITE 104 CARMEL INDLANA 46032 TEL 512.977.0520 FAX 512977.0384 12301 RESEARCH BLVD. BUILDING IV, SUITE 104 AUSTIN TEXAS 78759 www.carsondesigrLcom THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. COPYRIGHT 2003 CARSON DESIGN ASSOCIATES 0r_��I� ( SYMBOL LEGEND O KEYED NOTE > REFER TO DRAWING WHERE SHOWN. X WALL TYPE. SEE PLANS FOR LOCATION o SEE THIS SHEET FOR CONSTRUCTION. O WINDOW TYPE. SEE PLANS FOR LOCATION REFER TO WINDOW SCHEDULE. XXX DOOR NUMBER. REFER TO DOOR SCHEDULE OFICE 100 ROOM NAME, SIZE AND NUMBER. REFER 10-0 x 14-0 TO ROOM FINISH SCHEDULE - ELEVATION NUMBER SHEET NUMBER - SECTION NUMBER Y SHEET NUMBER REF; ??? — LLi --------; .� pcn ENLARGED PLAN LID U --------i Xxx FINISH NOTE. REFER TO ROOM FINISH LEGEND AND/OR FINISH PLAN. /X REVISION ELEVATION TARGET SEMI -RECESSED FIRE EXTINGUISHER/ FEC CABINET TO BE PROVIDED/INSTALLED BY G.C., SEE DETAIL THIS SHEET. PAINT CABINET TO MATCH DOOR FRAMES. (FE DENOTES FIRE EXTING. NO CABINET.) ;USPENDED ACOUSTICAL CEILING TILE. ?E: ROOM FIN. SCHED. FOR INFO. :HICAGO METALLIC ELIMINATOR 'RACK. BUILT IN TRIM EDGE W/ 3/4" 'ROTECTIVE TAPE. FLAT TAPE ONLY. ;PACKE AND SAND. -ILL WALL SOLID WITH SOUND ATTENUATION 3ATTS INSULATION IN THICKNESS TO MATCH REQUIRED METAL STUD SIZE. 1-5/8' METAL STUDS AT 6" O.C. WITH 5/8' GYPSUM BOARD ACH SIDE. 'LOOR UNE EXISTING CONDITIONS CHANGE ORDERS RE: ALL SHEETS EXISTING CONDITIONS SHOWN ON THESE DRAWINGS ARE BASED UPON BASE BUILDING OR OTHER CONSTRUCTION DOCUMENTS MADE AVAILABLE TO THE ARCHITECT BY THE BUILDING OWNER. UNLESS OTHERWISE NOTED, AS -BUILT ARCHITECTURAL CONDITIONS HAVE NOT BEEN FIELD VERIFIED AND MAY VARY FROM THOSE SHOWN. PRIOR TO SUBMITTING THE CONSTRUCTION BID, THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS AND ANY CRITICAL DIMENSIONS ASSOCIATED WITH THE PROPOSED WORK. THE CONTRACTOR SHALL CONFIRM THAT ALL WORK OUTLINED WITHIN THESE DOCUMENTS MAY BE ACCOMPLISHED AS SHOWN, PRIOR TO THE COMPLETION OF THE BIDDING PROCESS, AND SHALL NOTIFY BOTH THE ARCHITECT AND THE BUILDING OWNER OF ANY CONDITIONS ENCOUNTERED WHICH MAY EFFECT BUILDING CODE COMPLIANCE. LIFE SAFETY AND ISSUANCE OF A CERTIFICATE OF OCCUPANCY, THE TIMELY COMPLETION FOR THE PROJECT OR ESTABLISHED BUDGET OF SUCH WORK. NO ADDITIONAL FUNDS WILL BE APPROVED FOR WORK OMITTED FROM THE CONSTRUCTION BID DUE TO LACK OF VERIFICATION BY THE CONTRACTOR, EXCEPT AS OTHERWISE APPROVED BY THE OWNER FOR WORK ASSOCIATED WITH "HIDDEN" CONDITIONS NOT ACCESSIBLE PRIOR TO CONSTRUCTION. DOCUMENT APPROVAL CLIENT/TENANT DATE TITLE PROPERTY MANAGER DATE CARSON DESIGN ASSOCIATES DATE UPON EXECUTION, THE CLIENT AND PROPERTY MANAGER APPROVE ALL ASPECTS OF THE SCOPE OF WORK SHOWN IN THESE DOCUMENTS, INCLUDING DESIGN CONTENT, SCOPE OF CONSTRUCTION AND FINISH SELECTION FOR THE FOLLOWING PHASE: F1 SPACE PLANNING oPRELIMINARY PRICING F1 CONSTRUCTION DOCUMENTATION ALL COSTS INCURRED DUE TO MISINTERPRETATION OF THESE DOCUMENTS OR ANY CHANGES TO THE PROJECT REQUESTED AFTER SIGN -OFF SHALL NOT BE THE RESPONSIBILITY OF CARSON DESIGN ASSOCIATES AND SHALL BE Tur c(" E RESPONSIBILITY OF THE CLIENT. SHEET INDE DRWG Al DEMOLITION & CONSTRUCTION PLANS DRWG A2 REFLECTED CEILING & ELECTRICAL LOCATION DRWG A3 FINISH PLAN WALL LEGEND EXISTING PARTIPONS TO REMAIN. EXISTING PARTITNS TO BE REMOVED. SEE EMO DRAWING. NEW PARTITIONS TO BE CONSTRUCTED DESIGNATES INTERIOR WALL CONST, X TYPES. REFER TO FLOOR[ANS FOR LOCATIONS. REFER TO W TYPES ON THIS SHEET FOR ACTUAL F1L CONSTRUCTION WALL TYPE #1 NOTE: ALL WALLS ARE W1 UNLESS OTHERWISE NOTED. SUSPENDED ACOUSTICAL CER ING TILE. RE: ROOM FIN. SCHED. FOR INFO. CHICAGO METALLIC ELIMINATCR TRACK. BUILT IN TRIM EDGE W/ 3/4' PROTECTIVE TAPE. FLAT TAPE ONLY. SPACKLE AND SAND. 3-5/8" METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. FLOOR LINE 1A NO SCALE L G C� ^ CARSON DESIGN ASSOCIATES TEL 317.843.5979 FAX 317.843.5975 11590 N. MERIDIAN SUITE 104 CARMEL INDLANA 46032 TEL 512.977.0520 FAX 512977.0384 12301 RESEARCH BLVD. BUILDING IV, SUITE 104 AUSTIN TEXAS 78759 www.carsondesigrLcom THIS DRAWING AND THE IDEAS, CONCEPTS AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. COPYRIGHT 2003 CARSON DESIGN ASSOCIATES 0r_��I� ( .D11 o > N o t0 C= CD � z a � - U Y LLi .� pcn LID U LL DATE / ISSUE / INITIALS: 03/02/04 STATE SUBMITTAL/TENANT REVIEW SE SQUARE FOOTAGE: DRAWING TITLE: 0325802 03/02104 SHEET NUMBER: ao i N 11 41'l 1 :1 1 4 1-A1 NORTH BLDG. STD. BLDG. STD. WALL CABINETS WALL CABINETS PLASTIC LAMINATE COUNTERTOP WITH 4" H. BACKSPLASH BLDG. STD. BASE CABINETS APPLY VINYL BASE AT TOE KICK STAINLESS STEEL SINGLE BOWL SINK, GOOSNECK FAUCET W/ ADA COMPLIANT LEVERS APPLY VINLY BASE AT TOE KICK 3-A1. 1/2'=rte 1. DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED. UNLESS NOTED OTHERWISE CONTRACTOR SHALL BE RESPONSIBLE FOR THE OFF-SITE DISPOSAL OF ALL DEMOLITION ITEMS. 2. RELOCATED ITEMS SHALL BE CLEANED AND PLACED IN STORAGE, PER OWNER'S DIRECTIONS UNTIL ITEMS ARE READY TO BE REINSTALLED. IF ITEM IS DAMAGED DURING DEMOLITION OR RELOCATION IT SHALL BE REPAIRED OR REPLACED WITH NEW ITEM AS APPROVED BY OWNER AT NO EXPENSE TO OWNER. 3. DEMOLITION SHALL BE DONE WITHOUT DAMAGE TO EXISTING CONSTRUCTION TO REMAIN. WHERE SUCH DAMAGE OCCURS PATCH, REPAIR, OR RESTORE WALLS, FLOORS, CEILINGS, ETC TO MATCH EXISTING. PROVIDE SHORING, BRACING, OR SUPPORT AS REQUIRED TO PREVENT MOVEMENT OR SETTLEMENT OF EXISTING CONSTRUCTION. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF DEMOLITION ITEMS WITH THE OTHER TRADES PRIOR TO THE START OF DEMO WORK. 5. REMOVE ALL EXISTING CONSTRUCTION, ITEMS AND FINISHES MADE OBSOLETE BY, OR IN CONFLICT WITH NEW CONSTRUCTION -VERIFY WITH ARCH. REMOVE WIRING BACK TO SOURCE AT ALL OUTLETS ETC MADE OBSOLETE BY WALL REMOVAL OR ANY OTHER NEW CONSTRUCTION. 6. WHERE EXISTING WALLS, BULKHEADS, OR FINISHES ARE REMOVED OR PARTIALLY DEMOLISHED, EACH TRADE SHALL BE RESPONSIBLE FOR PATCHING OR REFINISHING OF EXISTING CONSTRUCTION REQUIRED BY THAT TRADES WORK ON THIS PROJECT. THIS WORK MUST BE DONE IN A MANNER WHICH WILL ACCEPT NEW FINISHES. 7. ALL CONTRACTORS ARE RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILING GRID AND/OR TILES IN ANY AREA WHERE THEY NEED ACCESS AND THE EXISTING CEILING IS TO REMAIN. UNLESS OTHERWISE NOTED, CONTRACTOR SHALL REPLACE ANY CEILING TILES OR GRID DAMAGED IN THIS PROCESS. 8. AT THE OWNER'S REQUEST SALVAGED ITEMS SHALL BE TURNED OVER TO THE OWNER OR STORED IN AN AREA DESIGNATED BY THE OWNER. 9. DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION TO BE DEMOLISHED ARE APPROXIMATE AND ARE INTENDED TO GIVE A GENERAL IDEA OF WORK TO BE REMOVED OR WORK TO BE TEMPORARILY REMOVED IN ORDER TO COMPLETE NEW CONSTRUCTION. COORDINATE DEMOLITION WORK WITH DESIGN INTENT OF NEW CONSTRUCTION TO PROVIDE ADEQUATE AREA FOR THIS WORK. 10. CONTRACTOR MUST FIELD VERIFY ALL AREAS AND/OR WORK TO BE DEMOLISHED PRIOR TO BEGINNING WORK. CONTRACTOR MUST COORDINATE WITH ARCHITECT ANY DIFFERENCES BETWEEN FIELD VERIFIED CONDITIONS AND/OR CONSTRUCTION, AND WHAT IS SHOWN ON DEMOLITION DRAWINGS. 11. PRIOR TO BEGINNING DEMOLITION, DUST CONTROL BARRIERS SHALL BE CONSTRUCTED TO PREVENT THE SPREAD OF DUST INTO SURROUNDING AREAS. 12. EXITING FROM STRUCTURE, IF REQUIRED TO PASS THROUGH DEMOLITION AREA(S), SHALL HAVE APPROVED BARRIERS ETC, TO INSURE SAFETY OF PUBLIC. 13. REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE AN EVEN FINISH. REFINISH ENTIRE ASSEMBLIES. CONTINUOUS SURFACES WILL BE TAKEN TO THE NEAREST INTERSECTION. 14. REMOVE ALL DIRT, DUST, DEBRIS ETC DAILY. DO NOT ALLOW REFUSE TO BLOCK CORRIDORS, STAIRS, OR ANY OTHER TRAFFIC AREA. 15. IT IS ESSENTIAL THAT THE CLIENT BE ABLE TO FUNCTION AS NORMAL AS POSSIBLE IN AREAS ADJACENT TO RENOVATION OR NEW CONSTRUCTION. PLASTIC LAMINATE COUNTERTOP WITH BACKSPLASH o 3' --,'BLDG. STD. BASE CABINETS GA 0 DUPLEX 2'-6" 10'-6' FIELD VERIFY DIMENSIONS 3' V/D a 2' 4-A1 trr= r� OG.C. TO PROVIDE AND INSTALL COAT ROD AND SHELF. SEE DETAIL 2-A3. OCENTER NEW WALL ON WINDOW MULLION. O3 ALIGN NEW WALL WITH COLUMN. ONEW RECEPTION DESK - METAL STUD AND GYP. BOARD CONSTRUCTION WITH PLASTIC LAMINATE WORKSURFACES. SEE ENLARGED PLAN 5-A1 AND SECTION 6-A1. O5 INFILL DOOR OPENING. CONSTRUCTION TO MATCH ADJACENT WALL. O NEW CABINETRY AND SINK. SEE ELEVATION AS INDICATED ON PLAN. ONEW CABINETRY. SEE ELEVATION AS INDICATED ON PLAN. OREFRIGERATOR (BY TENANT). G.C. TO PROVIDE WATERLINE FOR ICEMAKER. GENERAL FLOORh NOT ALL MAY APPLY. REFER TO PLANS FOR ADDITIONAL NOTES AND INFORMATION. INDICATES EXISTING PARTITIONS TO BE REMOVED. 1. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, JOB CONDITIONS, ETC. SEE DEMO DRAWING. 2. ALL DIMENSIONS ON PLANS ARE TO FINISHED FACE OF MTL STUD WALL, CONCRETE MASONRY UNIT OR BRICK. 3. WHERE DISSIMILAR FLOOR MATERIALS MEET THEY SHALL DO SO UNDER THE CENTERLINE OF THE DOOR, UNLESS NOTED OTHERWISE. ,� _ INDICATES EXISTING DOOR AND FRAME TO BE REMOVED.(OR DOOR do SIDELIGHT IF 4. PROVIDE DEEP LEG TRACKS AT ALL METAL STUD CONNECTIONS TO STRUCTURE ABOVE. UNLESS NOTED OTHERWISE. n INDICATED AS SUCH). NOTE: DOORS MAY BE RE -USED. COORDINATE WITH BUILDING 5, HINGE SIDE OF DOOR JAMBS IN METAL STUD WALLS WILL TYPICALLY BE LOCATED 4' FROM ADJACENT WALL. I I � OWNER POSSIBLE DOOR RE -USE. USE ONLY BEST CONDITION DOORS FOR THIS UNLESS NOTED OTHERWISE. SEE TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL INFORMATION. PURPOSE. REFER TO FLOOR PLANS FOR POSSIBLE NEW LOCATION. 6. PROVIDE FIRE RATED BLOCKING IN NEW METAL STUD WALLS AND EXISTING WALLS FOR ALL WALL SUPPORTED ITEMS. AT ALL EXISTING WALLS, PATCH AND REPAIR WALL FINISH TO MATCH ADJACENT WALL SURFACE FOLLOWING INSTALLATION OF BLOCKING. HATCHING INDICATES AREA NOT IN CONTRACT. REFER TO FLOOR PLANS 7. PROVIDE FIRE STOPPING AT PENETRATIONS OF ALL RATED WALLS. FOR ADDITIONAL INFORMATION. 8. REFER TO DEMOLITION PLAN FOR ALL REQUIRED DEMOLITION WORK. 9. REFER TO ROOM FINISH PLAN FOR ALL REQUIRED FINISH INFORMATION. 10. REFER TO DOOR SCHEDULE FOR ALL DOOR AND FRAME TYPES, HARDWARE INFORMATION AND ALL OTHER DOOR INFORMATION. 11. WHERE NEW WALL CONSTRUCTION IS SHOWN ABUTTING WINDOW MULLIONS, CENTER WALL CONSTRUCTION ON MULLION REFER TO TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL CONSTRUCTION INFORMATION. 12. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTING EXISTING CONSTRUCTION ALIGN FACE OF NEW CONST. WITH FACE OF EXISTING CONST. SEE TYPICAL DETAILS ON INDEX SHEET FOR ADDITIONAL INFORMATION. 13. ALL FINISHES SHALL CONFORM TO CHAPTER 8 OF THE 2000 INTERNATIONAL BUILDING CODE AND THE 2003 INDIANA AMENDMENTS. 14, WHERE POSSIBLE LEAVE 1'-6' OF UNOBSTRUCTED SPACE ON LATCH/PULL SIDE OF ALL DOORS AND i'-0' OF UNOBSTRUCTED SPACE ON LATCH/PUSH SIDE OF DOORS FOR ADA COMPLIANCE. 15. USE ONLY PLENUM RATED CABLE. 16. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS SCOPE OF WORK TO DISCONNECT AND RECONNECT TENANT'S EXISTING POWERED SYSTEMS FURNITURE. IF TENANT IS INSTALLING NEW POWERED SYSTEMS FURNITURE ELECTRICAL CONTRACTOR SHALL INCLUDE PRICE TO CONNECT. 17. UNLESS OTHERWISE NOTED ALL INTERIOR WALLS SHALL BE TYPE 11. SEE WALL TYPES ON INDEX SHEET FOR ADDITIONAL INFO. 18. PROVIDE CONTROL JOINTS IN ALL RUNS OF METAL STUD/GYP BD WALLS OVER 30' IN LENGTH. COORDINATE LOCATIONS WITH CARSON DESIGN ASSOCIATES PRIOR TO INSTALLATION FOR COMPLIANCE WITH DESIGN INTENT. PLASTIC LAMINATE TRANSACTION TOP 3' DIA. GROMMET PLASTIC LAMINATE WORKSURFACE INSTALLED AT 30' AFF. PROVIDE PLASTIC LAMINATE SUPPORTS AS REQ'D 3' DIA. GROMMET 5-A1. PAINTED GYP. BD. VINYL BASE NOTE: ALL NEW WALLS ARE WALL TYPE 1 UNLESS OTHERWISE NOTED. PLASTIC LAMINATE TRANSACTION TOP 10' 5/8' GYP. BOARD LAMINATE ZFACE 1.. DRYWALL L - METAL STUD CTION SE 6-A1, 2-A1 NORTH DOOR SCHEDULE FRAME DOOR NO. TYPE SIZE MATERIAL FINISH RATING MATERIAL FINISH TYPE RATING HEAD JAMB HDWRE. REMARKS 200 EXISTING N PAINTED EXISTING SIDELT. TO REMAIN. 201 RELOCATED 3'-0' X 6'-11" WOOD BLDG. STD. H.M. PAINTED z ■�+ 203 RELOCATED 3'-0' X 6'-11" WOOD BLDG. STD. Lu H.M. PAINTED O Cd _c:3� 205 RELOCATED 3'-0" X 6'-11" WOOD BLDG. STD. H.M. PAINTED W 206 RELOCATED 3'-0' X 6'-11" WOOD BLD. STD. H.M. PAINTED 207 EXISTING PAINTED 209 RELOCATED 6'-0' X 6'-11" WOOD BLD. STD. H.M. PAINTED 210 J RELOCATED --- I-- 3'-0' X 6'-11" - WOOD BLD. STD. H.M. PAINTED 1. REUSE EXISTING DOORS SALVAGED FROM TENANT SPACE. 2. ALL DOOR HARDWARE TO BE ADA COMPLIANT LEVER HARDWARE. REPLACE ANY EXISTING KNOBS WITH NEW HARDWARE TO MATCH EXISTING LEVERS. CARSON DESHM ASSOCIATES TEL 317.8435979 FAX 317.843.5975 11590 N. MERIDIAN SUITE 104 CARMEL INDIANA 46032 TEL 512977.0520 FAX 512.977.0384 12301 RESEARCH BLVD. BUILDING IV, SUITE 104 AUSTIN TEXAS 78759 -n'S DRAWING AND THE !DSAS, : CNCEP'S AND DESIGNS CONTAINED HEREIN ARE THE EXCLUSIVE 'NTELLECTUAL PICPE:^, OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. Q7 COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP P S PJ G�sTE �. AR 300093 • STATE OF DATE / ISSUE / INITIALS: 03/02/04 STATE SUBMITTAL/TENANT REVIEW SE SQUARE FOOTAGE: 0325802 MAIM SHEET NUMBER: Al cm m �- cm > N O C„ � z ■�+ Y U a Lu E O Cd _c:3� U ■ ® LL. W DATE / ISSUE / INITIALS: 03/02/04 STATE SUBMITTAL/TENANT REVIEW SE SQUARE FOOTAGE: 0325802 MAIM SHEET NUMBER: Al TELEMARKETING 206 RECEPTION 200 CO 201NCE 203 TELEMARKETING 206 RECEPTION 200 CO FEORENCE 203 CARSON DESm ASSOGAM TEL 317.8435979 FAX 317.843.5975 11590 N. MERIDIAN SUITE 104 CARMEL INDIANA 46032 TEIL 512.977.0520 FAX 512977.0384 12301 RESEARCH BLVD. BALDING N, SUITE 104 AUSTIN TEXAS 78759 www.car.com THIS DRAWING AND THE IDEAS, CONCEPTS AND DE AGNS CONTAINED HEREIN ARE THE EXCLUSIVE WTELLECTLAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TC BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT T -E WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES- © COPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP S. F NO 0� AR9300093 STATE OF 4, - AREUSE EXISTING SWITCHES IN THIS LOCATION FOR LIGHT FIXTURES IN RECEPTION 200 AND CORRIDORS 202 AND 204. 2OLOCATION OF NEW 3 -WAY SWITCHES FOR LIGHT FIXTURES IN CORRIDORS 202, 204, 209, AND OPEN OFFICE 207. O LOCATION OF NEW 3 -WAY SWITCHES FOR LIGHT FIXTURE IN OPEN AREA 207. REFLECTED CEILING PLA GENE NOTES REFLECTED CEILING PLAN LEGEND o R BUILDING STANDARD 2X4 $ WALL MOUNTED LIGHT SWITCH. COVER FLUORESCENT LIGHT FIXTURE 3 PLATE COLOR TO MATCH EXISTING TO BE RELOCATED. $ ADJACENT COVER PLATES. ("3" DENOTES 3 -WAY SWITCH.) 1. EXISTING SUSPENDED CEILING SYSTEM SHALL REMAIN. 2. REUSE EXISTING 2 X 4 LIGHT FIXTURES AS INDICATED IN NEW LIGHTING LAYOUT. 3. REFER TO INDEX SHEET FOR TYPCAL WALL TYPES (WALLS TO DECK, RATED WALLS, ETC) AND ADDITIONAL WALL -TO -CEILING DESIGN CONDITIONS AND CONSIDERATIONS. 4. PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED. 5. THE ARCHITECTURAL REFLECTED CEDING PLANS SHALL GOVERN THE LAYOUT OF ALL CEILING ELEMENTS AND/OR PENETRATIONS. COORDINATE WITH ARCHITECT ANY FIELD VERIFIED OR AS -BUILT CONDITIONS THAT DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 6. SIZES OF MECHANICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH MECHANICAL ENGINEER. 7. SIZES AND SHAPES OF LIGHTING AND OTHER MISC ELECTRICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECTRICAL ENGINEER. 8. IF POSSIBLE ANY CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING MECHANISMS, ETC) SHOULD BE CENTERED IN CEILING PANELS. WHERE EXISTING CEILING GRID IS REMODELED TO MEET NEW CONSTRUCTION THE CONTRACTOR SHALL; A REPLACE ALL DAMAGED OR UNREPAIRABLE PORTIONS OF EXISTING GRID WITH NEW GRID TO MATCH EXISTING BUILDING STANDARDS. B. REMOVE PORTIONS OF EXISTING GRID OR PROVIDE NEW GRID AS REQUIRED BY NEW CONSTRUCTION. ALL NEW GRID MUST MATCH EXISTING TO REMAIN OR BE BUILDING STANDARD. C. REPLACE ALL DAMAGED CEILING TILES WITH NEW TILES TO MATCH EXISTING TO REMAIN OR TO MATCH EXISTING BUILDING STANDARDS. ®NL BUILDING STANDARD 2X4 FLUORESCENT LIGHT FIXTURE ON NIGHT LIGHT CIRCUIT (U.O.N.) EXISTING CEILING GRID TO REMAIN. ):�R RELOCATED DOWNLIGHT. ® BUILDING STANDARD ILLUMINATED EXIT LIGHT SOLID DENOTES DIRECTION OF FACEPLATE. UNLESS NOTED WITH AN "N' OR AN 'R' ALL ITEMS SHOWN WILL BE EXISTING TO REMAIN. REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC CEILING TYPES AND HEIGHTS. REFER TO FLOOR PLANS FOR SPECIFIC WALL CONSTRUCTION. 1. THIS DRAWING IS INTENDED TO PROVIDE INFORMATION RELATING TO THE LOCATION OF WIRING DEVICES AND OUTLETS ONLY. IT IS THE RESPONSIBILITY OF THE ELECTRICAL DESIGN/BUILD CONTRACTOR TO PROVIDE NECESSARY DOCUMENTS RELATING TO THE ACTUAL ELECTRICAL INSTALLATION AND TO INSTALL ALL WIRING DEVICES IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. 2. ALL DIMENSIONS ARE FROM FINISHED WALL SURFACE OR COLUMN CENTERLINE TO CENTERLINE OF OUTLETS OR CENTERLINE OF PAIRS OF OUTLETS. 3. ALL WALL MOUNTED WIRING DEVICES AND RECEPTACLES SHOWN BACK TC BACK SHALL BE OFFSET A MINIMUM OF 8" AND ACOUSTICALLY SEALED. 4. WHERE DIRECT CONNECTION TO PREWIRED FURNITURE PANELS OCCURS, PROVIDE POWER AND TELECOMMUNICATION FEEDS TO INDICATED PANEL LOCATION FROM WALL, COLUMN OR FLOOR SOURCE DIRECTLY ADJACENT TO THIS LOCATION. COORDINATE EXACT REQUIREMENTS WITH TENANT'S FURNITURE DEALER. FURNITURE IS SHOWN FOR REFERENCE ONLY. 5. UNLESS OTHERWISE NOTED ALL DEVICE ELEVATIONS REFER TO BOTTOM OF OUTLET BOX. 6. REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF LIGHT SWITCHES. 7. ALL OUTLETS THAT ARE IN THE VICINITY OF ANY WET AREAS (KITCHENS, BREAK ROOMS, RESTROOMS, JANITORIAL ROOMS WITH FLOOR SINKS, LAUNDRY ROOMS, STAND ALONE WALL MOUNTED SINKS, ELECTRIC WATER FOUNTAINS,ETC.) GROUND FAULT INTERRUPT (G.F.I.) TYPE. SEE ELECTRICAL LEGEND. O PHONE BOARD. VERIFY EXACT REQUIREMENTS WITH TENANT. OREFRIGERATOR (BY TENANT) O PRINTER (BY TENANT) O LOCATION OF (2) FAX MACHINES AND (1) PRINTER ELECTRICAL LEGEND NOT ALL MAY APPLY. REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFO. ® BUILDING STANDARD FLOOR MOUNTED DUPLEX ELECTRICAL OUTLET. (4 -CIRCUIT TYPICAL U.O.N.) ® BUILDING STANDARD FLOOR MOUNTED DATA AND OR TELEPHONE LINE OUTLET. (4 -CIRCUIT TYPICAL U.O.N.) Q ccO JUNCTION BOX. BUILDING STANDARD WALL MOUNTED DUPLEX OUTLET. 220 220 OUTLET BUILDING STANDARD WALL MOUNTED Cl co � REFLECTED CEILING PLAN 1 -AZ ELECTRICAL LOCATION PLAN 2-A2 E z ire=ra Y U NORTH NORTH cC REFLECTED CEILING PLAN KEYNOTES ELECTRICAL LOCATION PLAN KEYNOTES ■tea W jL AREUSE EXISTING SWITCHES IN THIS LOCATION FOR LIGHT FIXTURES IN RECEPTION 200 AND CORRIDORS 202 AND 204. 2OLOCATION OF NEW 3 -WAY SWITCHES FOR LIGHT FIXTURES IN CORRIDORS 202, 204, 209, AND OPEN OFFICE 207. O LOCATION OF NEW 3 -WAY SWITCHES FOR LIGHT FIXTURE IN OPEN AREA 207. REFLECTED CEILING PLA GENE NOTES REFLECTED CEILING PLAN LEGEND o R BUILDING STANDARD 2X4 $ WALL MOUNTED LIGHT SWITCH. COVER FLUORESCENT LIGHT FIXTURE 3 PLATE COLOR TO MATCH EXISTING TO BE RELOCATED. $ ADJACENT COVER PLATES. ("3" DENOTES 3 -WAY SWITCH.) 1. EXISTING SUSPENDED CEILING SYSTEM SHALL REMAIN. 2. REUSE EXISTING 2 X 4 LIGHT FIXTURES AS INDICATED IN NEW LIGHTING LAYOUT. 3. REFER TO INDEX SHEET FOR TYPCAL WALL TYPES (WALLS TO DECK, RATED WALLS, ETC) AND ADDITIONAL WALL -TO -CEILING DESIGN CONDITIONS AND CONSIDERATIONS. 4. PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED. 5. THE ARCHITECTURAL REFLECTED CEDING PLANS SHALL GOVERN THE LAYOUT OF ALL CEILING ELEMENTS AND/OR PENETRATIONS. COORDINATE WITH ARCHITECT ANY FIELD VERIFIED OR AS -BUILT CONDITIONS THAT DIFFER FROM WHAT IS SHOWN ON THESE PLANS. 6. SIZES OF MECHANICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH MECHANICAL ENGINEER. 7. SIZES AND SHAPES OF LIGHTING AND OTHER MISC ELECTRICAL EQUIPMENT (IF SHOWN HERE) ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECTRICAL ENGINEER. 8. IF POSSIBLE ANY CEILING MOUNTED ITEMS (SPRINKLER HEADS, MOUNTING MECHANISMS, ETC) SHOULD BE CENTERED IN CEILING PANELS. WHERE EXISTING CEILING GRID IS REMODELED TO MEET NEW CONSTRUCTION THE CONTRACTOR SHALL; A REPLACE ALL DAMAGED OR UNREPAIRABLE PORTIONS OF EXISTING GRID WITH NEW GRID TO MATCH EXISTING BUILDING STANDARDS. B. REMOVE PORTIONS OF EXISTING GRID OR PROVIDE NEW GRID AS REQUIRED BY NEW CONSTRUCTION. ALL NEW GRID MUST MATCH EXISTING TO REMAIN OR BE BUILDING STANDARD. C. REPLACE ALL DAMAGED CEILING TILES WITH NEW TILES TO MATCH EXISTING TO REMAIN OR TO MATCH EXISTING BUILDING STANDARDS. ®NL BUILDING STANDARD 2X4 FLUORESCENT LIGHT FIXTURE ON NIGHT LIGHT CIRCUIT (U.O.N.) EXISTING CEILING GRID TO REMAIN. ):�R RELOCATED DOWNLIGHT. ® BUILDING STANDARD ILLUMINATED EXIT LIGHT SOLID DENOTES DIRECTION OF FACEPLATE. UNLESS NOTED WITH AN "N' OR AN 'R' ALL ITEMS SHOWN WILL BE EXISTING TO REMAIN. REFER TO ROOM FINISH SCHEDULE FOR SPECIFIC CEILING TYPES AND HEIGHTS. REFER TO FLOOR PLANS FOR SPECIFIC WALL CONSTRUCTION. 1. THIS DRAWING IS INTENDED TO PROVIDE INFORMATION RELATING TO THE LOCATION OF WIRING DEVICES AND OUTLETS ONLY. IT IS THE RESPONSIBILITY OF THE ELECTRICAL DESIGN/BUILD CONTRACTOR TO PROVIDE NECESSARY DOCUMENTS RELATING TO THE ACTUAL ELECTRICAL INSTALLATION AND TO INSTALL ALL WIRING DEVICES IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES. 2. ALL DIMENSIONS ARE FROM FINISHED WALL SURFACE OR COLUMN CENTERLINE TO CENTERLINE OF OUTLETS OR CENTERLINE OF PAIRS OF OUTLETS. 3. ALL WALL MOUNTED WIRING DEVICES AND RECEPTACLES SHOWN BACK TC BACK SHALL BE OFFSET A MINIMUM OF 8" AND ACOUSTICALLY SEALED. 4. WHERE DIRECT CONNECTION TO PREWIRED FURNITURE PANELS OCCURS, PROVIDE POWER AND TELECOMMUNICATION FEEDS TO INDICATED PANEL LOCATION FROM WALL, COLUMN OR FLOOR SOURCE DIRECTLY ADJACENT TO THIS LOCATION. COORDINATE EXACT REQUIREMENTS WITH TENANT'S FURNITURE DEALER. FURNITURE IS SHOWN FOR REFERENCE ONLY. 5. UNLESS OTHERWISE NOTED ALL DEVICE ELEVATIONS REFER TO BOTTOM OF OUTLET BOX. 6. REFER TO REFLECTED CEILING PLANS FOR LOCATIONS OF LIGHT SWITCHES. 7. ALL OUTLETS THAT ARE IN THE VICINITY OF ANY WET AREAS (KITCHENS, BREAK ROOMS, RESTROOMS, JANITORIAL ROOMS WITH FLOOR SINKS, LAUNDRY ROOMS, STAND ALONE WALL MOUNTED SINKS, ELECTRIC WATER FOUNTAINS,ETC.) GROUND FAULT INTERRUPT (G.F.I.) TYPE. SEE ELECTRICAL LEGEND. O PHONE BOARD. VERIFY EXACT REQUIREMENTS WITH TENANT. OREFRIGERATOR (BY TENANT) O PRINTER (BY TENANT) O LOCATION OF (2) FAX MACHINES AND (1) PRINTER ELECTRICAL LEGEND NOT ALL MAY APPLY. REFER TO ELECTRICAL PLAN FOR ADDITIONAL NOTES AND ELECTRICAL INFO. ® BUILDING STANDARD FLOOR MOUNTED BUILDING STANDARD WALL MOUNTED DEDICATED DUPLEX OUTLET. b BUILDING STANDARD WALL MOUNTED DATA LINE OUTLET R INDICATES EXISTING ITEM TO BE RE- LOCATED. ALL OTHER OUTLETS SHOWN ARE TO BE NEW. SEE NOTE BELOW. N INDICATES NEW ITEM LOCATION AS SHOWN. SEE NOTE BELOW. GFI INDICATES GROUND FAULT INTERRUPT OUTLET. +42 SPECIAL MOUNTING HEIGHT INDICATION FOR WALL OUTLETS. TAKEN TO BOTTOM OF PLATE NOTE: UNLESS NOTED WITH AN "R" OR AN 'N", ALL ITEMS WILL BE EXISTING TO REMAIN. NOTE: HVAC CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE HEATING, COOLING AND HUMIDITY CONTROL (AS APPLICABLE) IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. REFER TO MECHANICAL DRAWINGS FOR ALL LOCATIONS OF HVAC EQUIPMENT, EITHER SHOWN HERE OR NOT SHOWN HERE, AND COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE ANY CONFLICTS DISCOVERED BETWEEN ARCHITECT'S AND MECHANICAL ENGINEER'S DRAWINGS. NOTE: SPRINKLER CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE SPRINKLER LAYOUT IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. LAYOUT MUST MEET ALL APPLICABLE LOCAL AND STATE CODES. REFER TO SPRINKLER DRAWINGS FOR ALL LOCATIONS OF THAT EQUIPMENT, EITHER SHOWN OR NOT SHOWN HERE, AND COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE, AND MECHANICAL ENGINEER ANY CONFLICTS DISCOVERED BETWEEN SPRINKLER CONTRACTOR'S DRAWINGS AND ARCHITECT'S OR MECHANICAL ENGINEER'S DRAWINGS. NOTE: ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR THE REWIRING AND/OR RE -SWITCHING OF ALL LIGHT FIXTURES AND/OR LIGHT SWITCHES AS REQUIRED BY NEW CONSTRUCTION. COORDINATE WITH ARCHITECT ANY ADDITIONAL REQUIRED WORK NOT SHOWN HERE. ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER OTHER TRADES' DRAWINGS WHEN CONFLICTS ARISE. BRING CONFLICTS OR INCONSISTENCIES BETWEEN ARCHITECTURAL DRAWINGS AND DRAWINGS OF OTHER DISCIPLINES TO THE ATTENTION OF THE ARCHITECT. DATE / ISSUE / INITIALS: 03/02/04 STATE SUBMITTAL/TENANT REVIEW SE SQUARE FOOTAGE: DRAWING TITLE: REFL. CEILING, & ELECTRICAL PlAhS BUILDING STANDARD WALL MOUNTED I 14 TELEPHONE OUTLET JOB NO. IQ WALL MOUNTED TELEPHONE AND DATA LINE SHARED OUTLET. U25802 o 0z" SHEET NUMBER: A2 DUPLEX ELECTRICAL OUTLET. (4 -CIRCUIT TYPICAL U.O.N.) ® BUILDING STANDARD FLOOR MOUNTED DATA AND OR TELEPHONE LINE OUTLET. (4 -CIRCUIT TYPICAL U.O.N.) Q BUILDING STANDARD ELECTRICAL JUNCTION BOX. BUILDING STANDARD WALL MOUNTED DUPLEX OUTLET. 220 220 OUTLET BUILDING STANDARD WALL MOUNTED FOUR-PLEX ELECTRICAL OUTLET. BUILDING STANDARD WALL MOUNTED DEDICATED DUPLEX OUTLET. b BUILDING STANDARD WALL MOUNTED DATA LINE OUTLET R INDICATES EXISTING ITEM TO BE RE- LOCATED. ALL OTHER OUTLETS SHOWN ARE TO BE NEW. SEE NOTE BELOW. N INDICATES NEW ITEM LOCATION AS SHOWN. SEE NOTE BELOW. GFI INDICATES GROUND FAULT INTERRUPT OUTLET. +42 SPECIAL MOUNTING HEIGHT INDICATION FOR WALL OUTLETS. TAKEN TO BOTTOM OF PLATE NOTE: UNLESS NOTED WITH AN "R" OR AN 'N", ALL ITEMS WILL BE EXISTING TO REMAIN. NOTE: HVAC CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE HEATING, COOLING AND HUMIDITY CONTROL (AS APPLICABLE) IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. REFER TO MECHANICAL DRAWINGS FOR ALL LOCATIONS OF HVAC EQUIPMENT, EITHER SHOWN HERE OR NOT SHOWN HERE, AND COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE ANY CONFLICTS DISCOVERED BETWEEN ARCHITECT'S AND MECHANICAL ENGINEER'S DRAWINGS. NOTE: SPRINKLER CONTRACTOR WILL BE RESPONSIBLE FOR PROVIDING ADEQUATE SPRINKLER LAYOUT IN ALL SPACES FORMED BY NEW CONSTRUCTION AS WELL AS ANY EXISTING SPACES RECONFIGURED BY NEW CONSTRUCTION. LAYOUT MUST MEET ALL APPLICABLE LOCAL AND STATE CODES. REFER TO SPRINKLER DRAWINGS FOR ALL LOCATIONS OF THAT EQUIPMENT, EITHER SHOWN OR NOT SHOWN HERE, AND COORDINATE WITH ARCHITECT OR ARCHITECT'S FIELD REPRESENTATIVE, AND MECHANICAL ENGINEER ANY CONFLICTS DISCOVERED BETWEEN SPRINKLER CONTRACTOR'S DRAWINGS AND ARCHITECT'S OR MECHANICAL ENGINEER'S DRAWINGS. NOTE: ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR THE REWIRING AND/OR RE -SWITCHING OF ALL LIGHT FIXTURES AND/OR LIGHT SWITCHES AS REQUIRED BY NEW CONSTRUCTION. COORDINATE WITH ARCHITECT ANY ADDITIONAL REQUIRED WORK NOT SHOWN HERE. ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER OTHER TRADES' DRAWINGS WHEN CONFLICTS ARISE. BRING CONFLICTS OR INCONSISTENCIES BETWEEN ARCHITECTURAL DRAWINGS AND DRAWINGS OF OTHER DISCIPLINES TO THE ATTENTION OF THE ARCHITECT. DATE / ISSUE / INITIALS: 03/02/04 STATE SUBMITTAL/TENANT REVIEW SE SQUARE FOOTAGE: DRAWING TITLE: REFL. CEILING, & ELECTRICAL PlAhS BUILDING STANDARD WALL MOUNTED I 14 TELEPHONE OUTLET JOB NO. IQ WALL MOUNTED TELEPHONE AND DATA LINE SHARED OUTLET. U25802 o 0z" SHEET NUMBER: A2 CARSON DESIGN ASSOCIATES TEL 317.8435979 FAX 317.643.5975 11 S90 N. MERIDIAN SUITE 104 CARMEL INDIANA 46032 TEL 511977.0520 FAX 511977.0384 12301 RESEARCH BLVD. BUILDING IVB SUITE 104 AUSTIN TEXAS 78759 T -IS :RAWING AND THE IDEAS, CCNCEPTS -ND DESIGNS CCNTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CARSON DESIGN ASSOCIATES, AND ARE NOT TO BE USED OR REPRODUCED. WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CARSON DESIGN ASSOCIATES. © CnPYRIGHT 2003 CARSON DESIGN ASSOCIATES STAMP Q o�No. • STA F • ZRCHIT�'� co cc�-- _� L F— p O E00 z cz a w E O� z -C3 to CD W DATE / ISSUE / INITIALS: 03/02/04 STATE SUBMITTAL/TENANT REVIEW SQUARE FOOTAGE: DRAWING TITLE: '-SCHEDULES 0325OU OWN SHEET NUMBER: A3