Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
04030247 Building Plans
CLIENT KeyBank 2025 Ontario Ave, 4th Floor Cleveland, OH 44115 Mailcode: OH -01-00-0444 ARCHITECT / ADMINISTRATION vocon DESIGN INC 2450 Prospect Avenue Cleveland, Ohio 44115 Phone: 216-623-6800 Fax: 216-623-0410 Contact: Matthew Heisey E-MAIL: m_heisey@vocon.com 2450 Prospect Avenue Cleveland, Ohio 44115 Phone- 26 623-6800 Fax: '21'-623-0410 Contact: John C. Workley E-MAIL: j_workley@vocon.com ENGINEERING CONSULTANTS THORSON BAKER &Associates, INC. 3030 West Streetsboro Road Richfield, Ohio 44286 Phone: 330-659-6688 Fax: 330-659-6675 Contact: Jeff Miterko E-MAIL: tba@thorsonbaker.com Paul Tucker - Electrical Dale VanLehn- Mechanical Dave Nemeth- Structural CIVIL ENGINEERING By Landlord GENERAL CONTRACTOR To Be Determined CODE INFORMATION CONSTRUCTION DOCUMENT CONFORMANCE - GENERAL PROJECT DATA LATEST CONSTRUCTION CODE REQUIREMENTS: 2003 Indiana Building Code and Based on THe ICC International Building Code/ 2000 reference Accessibility COMPLIANCE: Americans with Disabilities Act of 1990, Title II & III IBC Chapter 11, ADDAG, AND ICC A 117.1-89 Note: There will be a workstation adjacent to the teller line with the designation "WS1". The function of this workstation is a "Personal Banker" and would service wheelchair bound customers. USE GROUP CLASSIFICATION: Section 30211 Group B: BUSINESS Section 304 BUILDING OCCUPANCY AND USE: B - BUSINESS; TYPE OF CON STRUCTI ON(Table 601): TYPE V -B BUILDING HEIGHT AND AREA: CHAPTER 5 ACTUAL AREA: Tenant Space Only ACTUAL BUILDING HEIGHT: Existing ACTUAL AREA - SQUARE FOOTAGE: Tenant AREA = 2,558 LOCATION MAP NDEX GF DRAWINGS FIRE RESISTANCE RATING for BUILDING ELEMENTS: (per Table 6A) G-1.0 TITLE SHEET, INDEX, LOCATION MAP SYMBOLS & ABBREVIATIONS, CODE BASED ON CONSTRUCTION TYPE TYPE IIB (213) INFORMATION STRUCTURAL FRAME: 0 ARCHITECTURAL DRAWINGS • BEARING - EXTERIOR WALLS: 0 `BEARING -INTERIOR WALLS: 0 A-1.0 FLOOR PLAN, DOOR SCHEDULE, DETAILS, SPECS & GENERAL NOTES A-2.0 REFLECTED CEILING PLAN _ (MIN. 20'-0" FIRE SEPARATION DISTANCE PER TABLE 5-A) A-4.0 FINISH & FLOORING PLANS, SPECS & LEGEND NON-BEARING -EXTERIOR WALLS AND PARTITIONS: TABLE 6A A-7.0 INTERIOR ELEVATIONS &DETAILS NON-BEARING - INTERIOR WALLS AND PARTITIONS: SECTION 6A A-8.0 TELLER STATION DETAILS FLOOR CONSTRUCTION: 0 ROOF CONSTRUCTION: 0 CONCEALED SPACES SECTION 708 PROVIDE FIREBLOCKING AND DRAFTSTOPS AT ALL WALLS AND OPENINGS NOT EXTENDING TO THE STRUCTURE ABOVE, ETC. FINISH INFORMATION: CHAPTER 8 FINAL FINISH SUBMITTALS TO BE PROVIDED BY CONTRACTOR FOR COMPLIANCE TO: INTERIOR FINISH & TRIM SHALL BE AS NOTED PER TABLE 8-B CLASS A - VERTICAL EXITS AND EXIT PASSAGEWAYS CLASS B - EXIT ACCESS CORRIDORS AND OTHER EXIT WAYS CLASS C - ROOMS AND ENCLOSED SPACES ALL (FLOOR COVERINGS - FIBERS) CARPET TO MEET RADIANT FLUX LIMITS BY NFPA - 253. A COPY OF TEST REPORTS SHALL IDENTIFY CARPET MRG, STYLE, NAME & REPRESENTATIVE OF CARPET AND SHALL BE PROVIDED TO APPROPRIATE BUILDING CODE OFFICIAL UPON REQUEST OF THE GENERAL CONTRACTOR DRAWING Exception. 36 MINIMUM CORRIDOR WIDTH IF LESS THAN 50 occuPANTs. ACCESSIBLE ROOMS AND SPACES INCLUDING FLOORS, WALKS, 1. DO NOT SCALE THE DRAWINGS. NFORMATION ABBREVIATIONS ACT - ACOUSTIC TILE - FLOOR DRAIN F. E. A.F.F. - ABOVE FINISHED FLOOR FIN - FINISH ALT - ALTERNATE - FLOOR FDN ALUM - ALUMINUM FPHB - FROST PROOF ANCH - ANCHOR HOSE BIBB F. S. APPROX - APPROXIMATELY FTG - FOOTING ARCH - ARCHITECT - FURRING FVC BR. CS. - BRICK COURSE GA - GAUGE BLDG - BUILDING - GALVANIZED GEN BLK - BLOCK GFRC - GLASS FIBER MEANS OF EGRESS: CHAPTER 10 ADAAG General Notes . B. - BBEAM MARK JosE - GLASS FIBER MAXIMUM OCCUPANT LOAD: BNT - BENT GL TOTAL NUMBER OF OCCUPANTS ALLOWABLE BY TABLE 10-A 1. THIS BUILDING SHALL COMPLY WITH THE PROVISIONS OF THE BTM - BOTTOM BUSINESS AREAS = 100 GSF/OCCUPANT - GYPSUM BOARD BASIN - HARDWARE ADAAG. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO, DOOR SIZES, CEM - CEMENT H. M. THRESHOLDS, DOOR PULLS, DOOR HARDWARE, GRAB BARS, CT - CERAMIC TILE TENANT FLOOR TOTAL H. P. C. J. - CONTROL JOINT HTG RESTROOM FIXTURES, TOILET PARTITIONS, ETC. THE FOLLOWING CUR. - CLEAR BUSINESS 2,558 G.S.F. / 100 S.F. PER OCC = 26 OCCUPANTS EXCERPTS FROM THEADAAG SHALL BE APPLIED TO THIS BUILDING CLG - CEILING INSUL ALLOWABLE OCCUPANT LOAD: = 26 OCCUPANTS INT CMU - CONCRETE MASONRY UNIT INV BUT IN NO WAY LIMIT THE APPLICABILITY OF THOSE SECTIONS NOT COL - COLUMN TOTAL OCCUPANTS BY ACTUAL NUMBER LAV COMP - COMPOSITION LG LISTED L. P. - LOW POINT/UGHT PANEL • CONC - CONCRETE ACTUAL OCCUPANT LOAD: 8 OCCUPANTS - MARBLE CONSTR - CONSTRUCTION (SEATS) EMPLOYEES 2. "VAN ACCESSIBLE" PARKING SPACE SHALL BE PROVIDED WITH A CONT - CONTINUOUS MECH SIGN THAT IS CLEARLY VISIBLE TO THE DRIVER OF A VEHICLE WHEN CONTR - CONTRACTOR OCCUPANCY LOAD USED FOR DESIGN AND POSTING: MFR CTR. - CENTER DESIGN OCCUPANT LOAD: 26 PARKING IN SUCH A LOCATION. A NOTICE SHALL BE AFFIXED TO THIS DET - DETAIL - MINIMUM SIGN OR POSTED ADJACENT TO IT THAT STATES THE AMOUNT OF D. F. - DRINKING FOUNTAIN THE FINE ESTABLISHED BY LAW FOR THE OFFENSE OF PARKING A DIA - DIAMETER EGRESS WIDTH PER OCCUPANT TABLE VEHICLE IN THIS LOCATION IF IT IS NOT LEGALLY ENTITLED TO DO SO. DIM -DIMENSION D. 0• - DOOR OPENING WITHOUT SPRINKLER SYSTEM OTHER EGRESS = 0.2 U CALCULATED NUMBER OF EXITS EGRESS WIDTH (ADAAG 4.1.2(5)(b)) DS - DOWNSPOUT WIDTH REQUIRED FOR EXITING = 26 OCCUPANTS x 0.2 =.52" DWG - DRAWING 3. THIS BUILDING SHALL BE ACCESSIBLE AT ALL PRIMARY EIFS - EXTERIOR INSULATION MIN. NUMBER OF EXITS REQ'D BY TABLE = 1 ENTRANCES AND SUCH ACCESSIBLE ROUT SHALL CONNECT ALL ''` FINISH ELEVATION ACTUAL NUMBER OF EXITS = 2 ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING. ALL EL - (SEAM LEVEL) ELEC - ELECTRICAL ACTUAL WIDTH OF EXITS = 72" > 15.2" EU U OBJECTS WHICH OVERHANG OR PROTRUDE INTO CIRCULATION ELEV - ELEVATION PATHS SHALL COMPLY WITH SECTION 4.4 OF THE ADAAG. GROUND EXIST'G - EXISTING SPACES W/ ONE MEANS OF EGRESS FOR MAX. OCCUPANT LOAD OF 50 PEOPLE PER TABLE FLOOR SURFACES ALONG ACCESSIBLE ROUTS AND IN ACCESSIBLE EXP - EXPANSION E. J. -EXPANSION JOINT & 75'-0" MAX. TRAVEL DISTANCE. v ROOMS AND SPACES SHALL COMPLY WITH 4.5 OF THE ADAAG. EXT - EXTERIOR Egress thru intervening spaces: Access thru accessory areas to area served with discernible path of (ADAAG 4.1.3 ACCESSIBLE BUILDINGS: NEW CONSTRUCTION) egress to exit is allowed per exceptions. CONTRACTOR NOTES: 44' MINIMUM EGRESS HALLWAYS/PASSAGEWAY WIDTH REQUIRED PER SECT. 1004.3.3 4. GROUND FLOOR SURFACES ALONG ACCESSIBLE ROUTS AND IN Exception. 36 MINIMUM CORRIDOR WIDTH IF LESS THAN 50 occuPANTs. ACCESSIBLE ROOMS AND SPACES INCLUDING FLOORS, WALKS, 1. DO NOT SCALE THE DRAWINGS. NFORMATION M. 0. ABBREVIATIONS F. D. - FLOOR DRAIN F. E. - FIRE EXTINGUISHER FIN - FINISH FLR - FLOOR FDN - FOUNDATION FPHB - FROST PROOF 0. D. HOSE BIBB F. S. - FULL SIZE FTG - FOOTING FURR - FURRING FVC - FIRE VALVE CABINET GA - GAUGE GALV - GALVANIZED GEN - GENERAL GFRC - GLASS FIBER POL REINFORCED CONCRETE GFRG - GLASS FIBER PTD REINFORCED GYPSUM GL - GLASS/GLAZING G. S. - GRAVEL STOP GYP. BD. - GYPSUM BOARD HDWE - HARDWARE HB - HOSE BIBB H. M. - HOLLOW METAL HORIZ - HORIZONTAL H. P. - HIGH POINT HTG - HEATING HYD - HYDRANT I. D. - INSIDE DIAMETER INSUL - INSULATION/INSULATING INT - INTERIOR INV - INVERT JT - JOINT LAV - LAVATORY LG - LONG L. P. - LOW POINT/UGHT PANEL LT - LIGHT MAR - MARBLE MAS - MASONRY MAX - MAXIMUM MECH - MECHANICAL MTL - METAL MFR - MANUFACTURER MH - MANHOLE MIN - MINIMUM MISC - MISCELLANEOUS M. 0. - MASONRY OPENING MET. POWER PLAN TRESH. - METAL THRESHOLD N. I. C. - NOT IN CONTRACT NO - NUMBER 0/A - OVERALL 0. C. - ON CENTER 0. D. - OUTSIDE DIAMETER OH - OVERHEAD 0/0 - OUT To OUT OPNG - OPENING PC - PIECE PL - PLATE PLAS - PLASTER PLBG - PLUMBING/PLUMBER PLYWD - PLYWOOD POL - POLISHED PROJ - PROJECTED/PROJECTION PTD - PAINTED R - RADIUS RAILG - RAILING R. D. - ROOF DRAIN REINF - REINFORCEMENT/ REINFORCED REQD - REQUIRED RM - ROOM R. 0. - ROUGH OPENING S - SINK SHT - SHEET S. M. - SHEET METAL SQ - SQUARE SPM - SINGLE PLY MEMBRANE S. S. - SLOPE/ SERVICE SINK S. STL - STAINLESS STEEL STD - STANDARD STRUCT. - STRUCTURAL/STRUCTURE SUSP - SUSPENDED T/ - TOP OF TERR - TERRAllO TYP. -TYPICAL VCT - VINYL COMPOSITION TILE W C. - WATER CLOSET WD - WOOD WT - WEIGHT W W F. WELDED WIRE FABRIC MINIMUM WIDTH OF EACH DOOR OPENING SHALL PROVIDE A CLEAR WIDTH OF AT LEAST RAMPS, STAIRS, AND CURB RAMPS, SHALL BE STABLE, FIRM, 32". SLIP -RESISTANT, AND SHALL COMPLY WITH 4.5. (ADAAG 4.5.1) 2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF ALL DOORS SHALL SWING IN DIRECTION OF EGRESS WHERE OCCUPANT LOAD IS GREATER 5. CHANGES IN LEVEL UP TO 1/4 INCH MAY BE VERTICAL AND THE WORK. COORDINATE ALL SITE REQUIREMENTS, ISSUES AND UTILITIES. THAN 50. WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BETWEEN 1/4 INCH REVIEW SOIL'S REPORT. DEAD END CORRIDORS - 20 FEET MAXIMUM AND 1/2 INCH SHALL BE BEVELED WITH SLOPE NO GREATER THAN 1:2. CHANGES IN LEVEL GREATER THAN 1/2 INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT COMPLIES WITH ADAAG 3. THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED EXIT ACCESS TRAVEL DISTANCE = 200'-0" PER TABLE 4.7 ORA.8. (ADAAG 4.5.2) IN THE CONTRACT DOCUMENTS. NOTIFY THE ARCHITECT IN WRITING FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. EXIT ACCESS DOOR SEPERATION DISTANCE 6. IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR 1/2 (OVERALL DIAGONAL DISTANCE) = 1/2 (73'-0") = 36'-6" REQ'D SURFACE THEN IT SHALL BE SECURELY ATTACHED; HAVE A FIRM ACTUAL = 49'-0" CUSHION, PAD, OR BACKING, OR NO CUSHION OR PAD; AND HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT/ UNCUT PILE TEXTURE. THE MAXIMUM PILE THICKNESS SHALL BE 1/2 INCH. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY. (ADAAG 4._.2 MECHANICAL/PLUMBING DRAWINGS M-1.0 MECHANICAL SCHEDULES & DETAILS M-2.0 MECHANICAL & PLUMBING PLAN ELECTRICAL DRAWINGS E-1.0 ELECTRICAL SCHEDULES & DETAILS E-2.0 POWER PLAN E-2.1 LIGHTING PLAN E-3.0 ELECTRICAL ONE LINE DIAGRAM & DETAILS KEYBANK VENDOR DRAWINGS Not Included in Permit Submittal SIGNAGE DRAWINGS BE -1 SIGNAGE DRAWING CABLING DRAWINGS D -1A MDF/ETO ROOM DETAILS D -2A DATA/VOICE STATION DETAILS D -3A BID INFORMATION SECURITY DRAWINGS DB -1 TITLE PAGE AND BACKCOUNTER LAYOUT DB -2 SECURITY LAYOUT DB -3 SECURITY LAYOUT vocon DESIGN INC. 2450 Prospect Aven Cleveland, Ohio 4411 216 623-6800 p. 216 623-0410 f. vocon©vocon.com EX °L C�C����C�C���, �12@ 2450 Prospect Ave. 1 s121fFrr-623-68 Cleveland, Ohio 44115216-623-0410 THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road(330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax I I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly registered Architect under the laws of the State of which governors this project. WARNING: per LAW No person may alter these document less person is, "or under the direct supervision of'th can d architect. Signature: S . rA1flt 1.0 10 -00 T -L., two. AR101UQ022 ;STATE OF 4 20. Type III Branch Proposed New Constru4n Carmel, IN 0 t r� W p, 10 o. ARx 0022 tAT,� 9 F � T ag�rj U 0 0 0 U 41 O Co I Ln O 01 REVISIONS:; ; U_ -- -� /\Issued for Bid and Permit 12/30/03 Job Number: 3626-000 F Z W zL C� [ O W o �•1 'i.. c`J xw� Q z v �ovC Z � dam• oza�� ¢���,� � � w 3U- z 70. v v ;6 u , ¢bU v�OI U� w �� W �7�.~ U ¢� z UPJ) C) wog tr vw�8 w=U o EU U ovcv r E . E � 0 Uo v W C N� ONr ¢ OU z z w v 0 KEYBANK VENDOR DRAWINGS Not Included in Permit Submittal SIGNAGE DRAWINGS BE -1 SIGNAGE DRAWING CABLING DRAWINGS D -1A MDF/ETO ROOM DETAILS D -2A DATA/VOICE STATION DETAILS D -3A BID INFORMATION SECURITY DRAWINGS DB -1 TITLE PAGE AND BACKCOUNTER LAYOUT DB -2 SECURITY LAYOUT DB -3 SECURITY LAYOUT vocon DESIGN INC. 2450 Prospect Aven Cleveland, Ohio 4411 216 623-6800 p. 216 623-0410 f. vocon©vocon.com EX °L C�C����C�C���, �12@ 2450 Prospect Ave. 1 s121fFrr-623-68 Cleveland, Ohio 44115216-623-0410 THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road(330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax I I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly registered Architect under the laws of the State of which governors this project. WARNING: per LAW No person may alter these document less person is, "or under the direct supervision of'th can d architect. Signature: S . rA1flt 1.0 10 -00 T -L., two. AR101UQ022 ;STATE OF 4 20. Type III Branch Proposed New Constru4n Carmel, IN 0 t r� W p, 10 o. ARx 0022 tAT,� 9 F � T ag�rj U 0 0 0 U 41 Drawn by: O Co I Ln O 01 REVISIONS:; ; U_ -- -� /\Issued for Bid and Permit 12/30/03 Job Number: 3626-000 Drawn by: JAC Checked by: MJK Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: Title Sheet Index, Location Map, Symbols Abbrev & Code Information Sheet Number: 11111111101 00 Original Date: December 16, 2003 WALL TYPE LEGEND TYPE RATING UL DESIGN DESCRIPTION DRAWING WIDTH F.O.F. 1599 Series H ages Ives Hager Stanley WS407CCV 3 5/8", 25 GA. @ 16" O.C. STEEL STUDS FROM FLOOR 3CB1AB700 CB179 Flat Goods Ives Trimco F-11- 3CB1HW AB750 CB168 - TO 6" ABOVE FINISHED CEILING WITH 5/8" GYPSUM 3CB1 AB800 C8191 4 7/8" 805 (DCI) PUSH/PUILL, THRESHOLD (AT 11010A ONLY), SWEEP AND GASKETING 698 9760 BOARD ON BOTH SIDES OF WALL. L%r;ks/Latches Schalge Best Yale WS407CCV W1274CCS 1326 20-091 1E74 2197 SR64 1337A SEE DWG # A-7.0 ND10S 93K ON 15D AU5401 LN 101 103 109 ND170 93K 1 DT 15D 455LN Panic Device (Von Duprin) (verify w/ arch.) 3 5/8", 20 GA. @ 16" O.C. STEEL STUDS FROM FLOOR ND40S 93K OL 15D 5402LN # 2670 7 - - TO MIN. 12'-0" ABV. FLOOR, WITH SOUND ATTENUATION Cnsers LCN Rixson Sargent 1EA WALL BUMPER WS407CCV 630 IVE 4011/4111 PRM2000CWF x SRI 280-P11 x RV x SRI 20-091 EVEREST BLANKETS BETWEEN AND 5/8" GYPSUM BOARD ON BOTH 4111 SCNS CSM2000CWF x SRI 280 -CPS x RV X SRI 4 7/8 4111 SCNS DOOR NUMBER: 689 102 SIDES OF WALL. (NOTE: USE MOISTURE RESISTANT GYP. EACH TO HAVE: SHALL HAVE 6 EA HINGE 3CB1HW 4.5 x 4.5 NRP ONLY), SWEEP AND GASKETING 652 HAG BD. IN WET AREAS) SEE DWG # A-7.0 1EA CONST LATCHING BOLT F861T (3/4" THROW WITH 7/8" VERTICAL ADJUST) 626 IVE 1 EA STOREROOM LOCK ND80RD RHO (EVEREST) 626 1 EA DUMMY TRIM ND170 RHO AND OBC SIGNAGE DETAILS SUPPLIED 6" STEEL STUDS WITH FOIL FACED, R-19, BATT VENDOR 2 EA OVERHEAD STOP 900S ❑3 - - INSULATION, 1/2" PAPER FACED GYPSUM SHEATHING, 7 1/2" HW SET: 04 fV MOISTURE BARRIER AND 8" EXPOSURE CEDAR LAP SIDING 104 F4 - - - F - - 3 EA SILENCER SR64 GRY IVE HW SET. 05 © DOOR NUMBER: V) X - INDICATES WALLS TO HAVE SOUND ATTENUATION BLANKETS AND MOISTURE RESISTANT GYP. BD. ON ONE SIDE. IVE INDICATES WALLS TO HAVE SOUND ATTENUATION BLANKETS AND PAINTED 3/4" PLYWOOD PANEL OVER GYP. BD. ON ONE SIDE. �' 3 INDICATES WALLS TO HAVE SOUND ATTENUATION BLANKETS G.C. TO VERIFY WITH LANDLORD SCOPE OF WORK. GENERAL NOTES 1. THE CONTRACT DOCUMENTS ARE INSTRUMENTS OF SERVICE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY ARE PREPARED IS EXECUTED OR NOT. THE CONTRACT DOCUMENTS ARE NOT TO BE USED BY LANDLORD OR TENANT FOR OTHER PROJECTS OR EXTENSIONS TO THE PROJECT NOR ARE THEY TO BE MODIFIED IN ANY MANNER WHATSOEVER EXCEPT BY AGREEMENT IN WRITING AND WITH APPROPRIATE COMPENSATION TO THE ARCHITECT. 2. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. VERIFY DIMENSIONS WITH FIELD CONDITIONS. IF DISCREPANCIES ARE DISCOVERED BETWEEN FIELD CONDITIONS AND DRAWINGS OR BETWEEN DRAWINGS, CONTACT ARCHITECT FOR RESOLUTION BEFORE PROCEEDING. 3. HORIZONTAL DIMENSIONS INDICATED ARE TO/FROM FINISHED FACE OF CONSTRUCTION, EXCEPT AS NOTED, 4. VERTICAL DIMENSIONS ARE FROM TOP OF FLOOR SLAB, EXCEPT WHERE NOTED TO BE FROM ABOVE FINISHED FLOOR. (A.F.F.) 5. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT APPROVAL OF ARCHITECT UNLESS OTHERWISE NOTED. 6. MAKE ALL NECESSARY PROVISIONS FOR ITEMS AS INDICATED ON THE DRAWINGS TO BE FURNISHED OR INSTALLED BY TENANT. PROVIDE PROTECTION FOR THESE PROVISIONS UNTIL COMPLETION OF THE PROJECT. GENERAL CONTRACTOR TO COORDINATE PROVISIONS FOR N.I.C. ITEMS WITH APPROPRIATE TRADES. 7. GENERAL CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST IN LOCATIONS OF ANY AND ALL MECHANICAL, TELEPHONE, ELECTRICAL, PLUMBING AND SPRINKLER EQUIPMENT (TO INCLUDE ALL PIPING, DUCT WORK, STRUCTURAL MEMBERS AND CONDUIT) AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ABOVE EQUIPMENT ARE PROVIDED, ELEMENTS TO BE EXPOSED OR CONCEALED SHALL BE DETERMINED AND REVIEWED WITH ARCHITECT PRIOR TO CONSTRUCTION PROCEEDING. 8. GENERAL CONTRACTOR AND SUB -CONTRACTORS SHALL COORDINATE THE LAYOUT AND EXACT LOCATION OF ALL PARTITIONS, DOORS, ELECTRICAL/TELEPHONE OUTLETS AND LIGHT SWITCHES WITH KEY BANK CONSTRUCTION MGR. IN THE FIELD BEFORE PROCEEDING WITH CONSTRUCTION. 9. CONTRACTOR SHALL PROVIDE MANUFACTURER'S SPECIFICATIONS & INSTALLATION INSTRUCTIONS, SHOP DRAWINGS & SAMPLES FOR REVIEW & APPROVAL OF ALL MATERIALS, METHODS, AND TRADES TO BE USED PRIOR TO ORDERING OR PROCEEDING WITH THE WORK. 10. CONTRACTOR SHALL NOTIFY ARCHITECT, IN WRITING IMMEDIATELY TO RESOLVE DISCREPANCIES TO CONTRACT DOCUMENTS PRIOR TO PROCEEDING. 11. THE CONTRACT DOCUMENTS CONSIST OF THE FOLLOWING: A. DRAWINGS B. ANY AND ALL ADDENDA 12. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, AMENDMENTS, RULES, REGULATIONS, ORDINANCES, LAWS, ORDERS, APPROVALS, ETC., THAT ARE REQUIRED BY PUBLIC AUTHORITIES. IN THE EVENT OF CONFLICT, THE MOST STRINGENT REQUIREMENTS SHALL GOVERN. REQUIREMENTS INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO, THE CURRENTLY APPLICABLE EDITIONS OR PUBLICATIONS OF THE FOLLOWING: A. LATEST EDITION PROJECT SITE STATE CODE B. NATIONAL FIRE PROTECTION ASSOCIATION C. AMERICAN NATIONAL STANDARDS INSTITUTE D. ALL LOCAL AND MUNICIPAL CODES 13. IN THE EVENT OF CONFLICT BETWEEN DATA SHOWN ON DRAWINGS & OVER DRAWINGS OF LARGER SCOPE, SHOULD THE CONTRACTOR AT ANY TIME DISCOVER AN ERROR IN A DRAWING OR SPECIFICATION, OR A DISCREPANCY OR VARIATION BETWEEN DIMENSIONS OR DRAWINGS AND MEASUREMENTS AT SITE, OR LACK OF DIMENSIONS OR OTHER INFORMATION, HE SHALL NOT PROCEED WITH THE WORK AFFECTED UNTIL CLARIFICATION HAS BEEN MADE WITH ARCHITECT. 14. ONLY NEW ITEMS OF RECENT MANUFACTURER, OF STANDARD QUALITY, FREE FROM DEFECTS, WILL BE PERMITTED ON THE WORK. REJECTED ITEMS SHALL BE REMOVED IMMEDIATELY FROM THE WORK AND REPLACED WITH ITEMS OF THE QUALITY SPECIFIED. FAILURE TO REMOVE REJECTED MATERIALS AND EQUIPMENT SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY FOR QUALITY AND CHARACTER OF ITEMS USED NOR FROM ANY OTHER OBLIGATION IMPOSED ON HIM BY THE CONTRACT. 15. THE FINISHED WORK SHALL BE FIRM, WELL ANCHORED, IN TRUE ALIGNMENT, PLUMB, LEVEL, WITH SMOOTH, CLEAN, UNIFORM APPEARANCES WITHOUT WAVES, DISTORTIONS, HOLES MARKS, CRACKS, STAINS, OR DISCOLORATION. JOINTING SHALL BE CLOSE FITTING, NEAT AS WELL SCRIBED. THE FINISH WORK SHALL HAVE NO EXPOSED UNSIGHTLY ANCHORS OR FASTENERS AND SHALL NOT PRESENT HAZARDOUS, UNSAFE CORNERS, ALL WORK SHALL HAVE THE PROVISION FOR EXPANSION, CONTRACTION, AND SHRINKAGE AS NECESSARY TO PREVENT CRACKS, BUCKLING AND WARPING DUE TO TEMPERATURE AND HUMIDITY CONDITIONS. 16. ATTACHMENTS, CONNECTIONS, OR FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH BEST PRACTICE AND THE CONTRACTOR IS RESPONSIBLE FOR IMPROVING THEM ACCORDINGLY AND TO THESE CONDITIONS. THE DRAWINGS SHOW ONLY SPECIAL CONDITIONS TO ASSIST CONTRACTOR. THEY DO NOT ILLUSTRATE EVERY SUCH DETAIL. 17. THE CONTRACTOR SHALL CONTINUOUSLY CHECK ARCHITECTURAL AND STRUCTURAL CLEARANCES FOR ACCESSIBILITY OF EQUIPMENT AND MECHANICAL AND ELECTRICAL SYSTEMS. NO ALLOWANCE OF ANY KIND WILL BE MADE FOR THE CONTRACTOR'S NEGLIGENCE TO FORESEE MEANS OF INSTALLING EQUIPMENT INTO POSITION INSIDE STRUCTURES. 18. NO WORK DEFECTIVE IN CONSTRUCTION OR QUALITY OR DEFICIENT IN ANY REQUIREMENTS OF DRAWINGS AND SPECIFICATIONS WILL BE ACCEPTABLE IN CONSEQUENCE OF OWNER'S OR ARCHITECT'S FAILURE TO DISCOVER OR TO POINT OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION; NOR WILL PRESENCE OF INSPECTORS ON WORK RELIEVE CONTRACTOR FROM RESPONSIBILITY FOR SECURING QUALITY AND PROGRESS OF WORK AS REQUIRED BY CONTRACT. DEFECTIVE WORK REVEALED WITHIN REQUIRED TIME GUARANTEES SHALL BE REPLACED BY WORK CONFORMING WITH INTENT OF CONTRACT. NO PAYMENT WHETHER PARTIAL OR FINAL, SHALL BE CONSTRUED AS AN ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS. 19. MATERIALS AND WORKMANSHIP SPECIFIED BY REFERENCE TO NUMBER, SYMBOL, TO TITLE OF A SPECIFICATION SUCH AS COMMERCIAL STANDARDS, FEDERAL SPECIFICATION, TRADE ASSOCIATION STANDARD, OR OTHER SIMILAR STANDARD, SHALL COMPLY WITH REQUIREMENTS IN LATEST EDITION OR REVISION THEREOF AND WITH ANY AMENDMENT OR SUPPLEMENTAL THERETO IN EFFECT ON DATE OF ORIGIN OF THIS PROJECT'S CONTRACT DOCUMENTS, SUCH STANDARD, EXCEPT AS MODIFIED HEREIN, SHALL HAVE FORCE AND EFFECTS AS THOUGH PRINTED IN CONTRACT DOCUMENTS. 20. CONTRACTOR SHALL WAIVE "COMMON PRACTICE" AND "COMMON USAGE" AS CONSTRUCTION CRITERIA WHEREVER DETAILS AND CONTRACT DOCUMENTS OR GOVERNING CODES, ORDINANCES, ETC., REQUIRE GREATER QUANTITY OR BETTER QUALITY THAN COMMON PRACTICE OR COMMON USAGE WOULD REQUIRE. 21. CONTRACTOR SHALL ORDER AND SCHEDULE DELIVERY OF MATERIALS IN AMPLE TIME TO AVOID DELAYS IN CONSTRUCTION. IF AN ITEM IS FOUND TO BE UNAVAILABLE OR HAVE A LONG LEAD TIME, CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY. 22. IF AT ANY TIME BEFORE COMMENCEMENT OF WORK, OR DURING PROGRESS THEREOF, CONTRACTOR'S METHODS, EQUIPMENT OR APPLIANCES ARE INEFFICIENT OR INAPPROPRIATE FOR SECURING QUALITY OF WORK, OR RATE OF PROGRESS INTENDED BY CONTRACT DOCUMENTS, OWNERS MAY ORDER CONTRACTOR TO IMPROVE THE QUALITY OR INCREASE THEIR EFFICIENCY. THIS WILL NOT RELIEVE CONTRACTOR OF HIS SURETIES FROM THEIR OBLIGATIONS TO SECURE QUALITY OR WORK AND RATE OF PROGRESS SPECIFIED IN CONTRACT. 23. ALL TELEPHONE AND DATA WORK SHALL BE COORDINATED BY THE CONTRACTOR WITH TENANT'S REPRESENTATIVE. 24. REFERENCES TO MAKES, BRANDS, MODELS, ETC., IS TO ESTABLISH TYPE AND QUALITY DESIRED; SUBSTITUTION OF ACCEPTABLE EQUALS WILL NOT BE PERMITTED UNLESS SPECIFICALLY NOTED OTHERWISE WHEN MADE ACCORDINGLY TO PROCEDURES FOR SUBSTITUTIONS. 25. FLOOR TOLERANCE: FINISHED FLOOR STABS TO BE LEVELED TO A TOLERANCE OF 1/8" SLOPE IN 12 FEET. G,C. TO IMMEDIATELY VERIFY SLOPE AND REPORT ANY DEVIATIONS FROM ABOVE STATED TOLERANCE TO ARCHITECT PRIOR TO COMMENCING WORK. ALIGNMENT OF DOOR HEADS AND OTHER CRITICAL HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT A CONSTANT LEVEL AND SHALL NOT FOLLOW VARIATIONS IN FLOOR PLANES. G.C. IS RESPONSIBLE TO LEVEL FLOOR TO MEET ACCEPTABLE TOLERANCE. 26. ALL PARTITIONS TO STRUCTURE ARE FOR ACOUSTICAL SEPARATION AND/OR SECURITY, NOT FOR FIRE RATING, UNLESS OTHERWISE NOTED (U.O.N.) 27. PARTITION TYPES ABOVE DOOR ARE TO BE SAME AS THE ADJACENT PARTITIONS U.O.N. 28. PARTITIONS SHOWN TO ALIGN WITH THE FACE OF EXISTING CONSTRUCTION OR NEW PARTITIONS SHOULD ALIGN FINISHED FACE TO FINISHED FACE. LAMINATE ADDITIONAL LAYER OF GYP. BD. FROM NEW TO EXISTING CONSTRUCTION AS REQUIRED TO PRODUCE FLUSH APPEARANCE WITH NO VISIBLE JOINTS. 29. DIMENSIONS INDICATED TO BE "CLEAR" SHALL BE MAINTAINED. ANY DISCREPANCIES OR VARIATIONS IN THESE DIMENSIONS SHALL BE REVIEWED WITH ARCHITECT BEFORE PROCEEDING. 30. PROVIDE RETURN AIR OPENINGS ABOVE CEILING IN PLENUM TO ROOMS WITH SLAB TO SLAB PARTITIONS, AS SIZED AND LOCATED ON ENGINEERING DRAWINGS. REPORT ANY CONFLICTS OR DISCREPANCIES TO ARCHITECT PRIOR TO PROCEEDING. 31, ANY DIMENSION NOTED "VERIFY" MUST BE REVIEWED WITH ARCHITECT BEFORE BEGINNING CONSTRUCTION. 32. PROVIDE AND INSTALL FIRE RETARDANT WOOD BLOCKING AS REQUIRED AT ALL WALL HUNG SHELVING, CABINETS, WOOD PANELS, EQUIPMENT, LIGHT FIXTURES, ETC. U.O.N. VERIFY SHOP STANDARD WITH MILLWORK SUBCONTRACTOR AND REVIEW WITH ARCHITECT FOR ACCEPTANCE PRIOR TO INSTALLATION. 33. GC TO COORDINATE AND REVIEW WITH ARCHITECT THE SIZE AND LOCATION OF ALL SLAB PENETRATIONS PRIOR TO BEGINNING ANY WORK, FIRE STOP AS REQUIRED TO MEET ALL APPLICABLE CODES. 34. ALIGN MEANS SIMILAR COMPONENTS OF CONSTRUCTION, I.E., WALLS, JAMBS, ETC, SHALL BE IN LINE ACROSS VOIDS. 35. DOTTED LINE INDICATES GYP. BD. SOFFIT ABOVE, SEE REFLECTIVE CEILING PLAN AND/OR DETAILS NOTED FOR EXACT HEIGHT. 36, CUSTOM MILLWORK, DOTTED LINE INDICATED MILLWORK ABOVE. SEE ELEVATIONS FOR MORE INFORMATION. 37. CUSTOM MILLWORK, UNLESS OTHERWISE NOTED, ARCHITECTURAL MILLWORK SHALL COMPLY WITH ARCHITECTURAL WOODWORK INSTITUTE (AWI) QUALITY STANDARS PREMIUM GRADE SEAL ALL WOOD SURFACES NOT RECEIVING PAINT OR PLASTIC LAMINATE, TO PREVENT MOISTURE PENETRATION. 38. GENERAL CONTRACTOR TO MAINTAIN RECORD DRAWINGS AND PROVIDE OWNER WITH AS-BUILTS UPON PROJECT COMPLETION. 39. GENERAL CONTRACTOR SHALL PROVIDE ALL EQUIPMENT MANUALS, WARRENTS AND PROJECT LITERATURE TO OWNER'S PROJECT MANAGER UPON PROJECT COMPLETION, 40. INSTALL BLOCKING IN WALLS FOR ALL CASEWORK, SHELVING, COUNTERTOPS, TOILET ACCESSORIES AND BANKING EQUIPMENT AS REQUIRED PER ITEM, ETC. NOTE: G.C. TO CONTACT KEYBANK'S NAT'L ACCOUNT DOOR HARDWARE REP. THOMAS A. PEKOC (216 378-2155 FOR ORDERING. CONTACT KEYBANK CONSTRUCTION MANAGER PRIOR TO ORDERING ANY FINAL HARDWARE STYLE TYPE AND CYLINDERS. S 3 A1.0 1 * INDICATES SECTION NUMBER A1.0 INDICATES DWG SHEET NUMBER FRAME TYPES cV VARIES 2" TYPE 1 0 I 0 7'- 7" TYPE 2 DOOR SCHEDULE I 0 7'-7„ 3'-0" 3'-1" 5', 3'-8" v -R„ DOOR TYPES S-0" SOUD CORE WOOD DOOR PAINT GRADE PLAIN SUCED do PRE -MACHINED 0 1 I� FLUSH PANEL TYPE A TYPE 3 TYPE 4 FLOOR PLAN A 1.0) SCALE: 1/4" = 1'- 0" HEAD DETAILS JAMB DETAILS 5/8" GYP. BD. EACH SIDE +, OF METAL STUDS » NOTE: TYP. ALL DOOR JAMBS ARE MIN. 4 1/2le 4" AWAY FROM ADJACENT WALL SEALANT @ PERIMETER OF FRAMEry- 0_ cV H 0_ H DOUBLE STUDS TO CONT. X DEFLECTION T TO STRUCTURE ABOVE W H.M. DRYWALL FRAME HORIZONTAL CLEAR 12� ; irl ANOD.ALUM. O SEE SCHEDULE FOR DOOR STOREFRONT MULLION SEALANT @ PERIMETER OFFICES LL. TYPE & MATERIAL TYP. T. ALUM. STOREFRONT H.M. DRYWALL FRAME li li STANDARD COMMERCIAL GRADE „ DOOR. 2 TYP. H 1 TYPE H1 H2 TYPE H2 1 TYPE J1 J2 TYPE J2 A1.0 A1.0 Al .0 A1.0 HARDWARE SPECIFICATION 3'-0" 2" 4'-1„ P-Auct Specified Acceptable #1 Acceptable #2 Overhead Stops Glynn Johnson Rixson N O I REMARKS 900S 9 1599 Series H ages Ives Hager Stanley WS407CCV TYPE 2 DOOR SCHEDULE I 0 7'-7„ 3'-0" 3'-1" 5', 3'-8" v -R„ DOOR TYPES S-0" SOUD CORE WOOD DOOR PAINT GRADE PLAIN SUCED do PRE -MACHINED 0 1 I� FLUSH PANEL TYPE A TYPE 3 TYPE 4 FLOOR PLAN A 1.0) SCALE: 1/4" = 1'- 0" HEAD DETAILS JAMB DETAILS 5/8" GYP. BD. EACH SIDE +, OF METAL STUDS » NOTE: TYP. ALL DOOR JAMBS ARE MIN. 4 1/2le 4" AWAY FROM ADJACENT WALL SEALANT @ PERIMETER OF FRAMEry- 0_ cV H 0_ H DOUBLE STUDS TO CONT. X DEFLECTION T TO STRUCTURE ABOVE W H.M. DRYWALL FRAME HORIZONTAL CLEAR 12� ; irl ANOD.ALUM. O SEE SCHEDULE FOR DOOR STOREFRONT MULLION SEALANT @ PERIMETER OFFICES LL. TYPE & MATERIAL TYP. T. ALUM. STOREFRONT H.M. DRYWALL FRAME li li STANDARD COMMERCIAL GRADE „ DOOR. 2 TYP. H 1 TYPE H1 H2 TYPE H2 1 TYPE J1 J2 TYPE J2 A1.0 A1.0 Al .0 A1.0 HARDWARE SPECIFICATION LOCATION P-Auct Specified Acceptable #1 Acceptable #2 Overhead Stops Glynn Johnson Rixson Brookline REMARKS 900S 9 1599 Series H ages Ives Hager Stanley WS407CCV EACH TO HAVE: 3CB1AB700 CB179 Flat Goods Ives Trimco Brookline 3CB1HW AB750 CB168 8400 K0050 K0600 3CB1 AB800 C8191 FB61T 3820 805 (DCI) PUSH/PUILL, THRESHOLD (AT 11010A ONLY), SWEEP AND GASKETING 698 9760 1361 L%r;ks/Latches Schalge Best Yale WS407CCV W1274CCS 1326 20-091 1E74 2197 SR64 1337A 1229A ND10S 93K ON 15D AU5401 LN 101 103 109 ND170 93K 1 DT 15D 455LN Panic Device (Von Duprin) (verify w/ arch.) (verify w/ arch.) ND40S 93K OL 15D 5402LN # 2670 MS1850S ND80RD 93K 7D 15D AU5405LN X 1220 1 EA OVERHEAD STOP 900S (AT 103) 630 Cnsers LCN Rixson Sargent 1EA WALL BUMPER WS407CCV 630 IVE 4011/4111 PRM2000CWF x SRI 280-P11 x RV x SRI 20-091 EVEREST 3 EA SILENCER SR64 4111 SCNS CSM2000CWF x SRI 280 -CPS x RV X SRI HW SET- 03 4111 SCNS NO. LOCATION DOOR FRAME HW SET. 01 REMARKS DOOR NUMBER: SCH 100A 1008 WS407CCV EACH TO HAVE: IVE 4 EA HINGE 3C81 4.5 X 4.5 NRP 630 IVE SR64 2 EA DEADLOCK MS1850S 628 ADA GRY IVE 2 EA IC MORTISE CYLINDER 20-091 EVEREST 626 SCH DETAILS PUSH/PUILL, THRESHOLD (AT 11010A ONLY), SWEEP AND GASKETING BY ALUMINUM DOOR VENDOR. SEE G.C. TO COORD. FOR LOGO AND OBC SIGNAGE DETAILS SUPPLIED BY SIGNAGE VENDOR HW SET: 02 DOOR NUMBER: 3CB1 4.5 X 4.5 101 103 109 EACH TO HAVE: 3 EA HINGE 3CB1 4.5 x 4.5 NOTE: ALL EXTERIOR DOORS 1 EA STOREROOM LOCK ND80RD RHO (EVEREST) 626 SCH MS1850S 1 EA SURFACE CLOSER 4011/4111 AS REQUIRED 689 LCN 1 EA OVERHEAD STOP 900S (AT 103) 630 GLY 1EA WALL BUMPER WS407CCV 630 IVE 1 EA PEEP HOLE 698 (VERIFY W/ CM IF NEEDED AT 103 626 IVE 20-091 EVEREST 3 EA SILENCER SR64 GRY IVE HW SET- 03 4111 SCNS DOOR NUMBER: 689 102 EACH TO HAVE: SHALL HAVE 6 EA HINGE 3CB1HW 4.5 x 4.5 NRP ONLY), SWEEP AND GASKETING 652 HAG 1EA CONST LATCHING BOLT F861T (3/4" THROW WITH 7/8" VERTICAL ADJUST) 626 IVE 1 EA STOREROOM LOCK ND80RD RHO (EVEREST) 626 1 EA DUMMY TRIM ND170 RHO AND OBC SIGNAGE DETAILS SUPPLIED 626 SCH VENDOR 2 EA OVERHEAD STOP 900S 630 GLY 2 EA SILENCER SR64 GRY IVE HW SET: 04 fV V) 104 EACH TO HAVE: 1EA PASSAGE LATCH ND10S RHO 626 SCH 1 EA OVERHEAD STOP 900S 630 GLY NON-REMOVEABLE HINGE 3 EA SILENCER SR64 GRY IVE HW SET. 05 DOOR NUMBER: V) X EACH TO HAVE: J X IVE 1EA STOREROOM LOCK ND80RD RHO (EVEREST) 626 SCH 1 EA WALL BUMPER WS407CCV 630 IVE �' 3 PINS IVE HW SET -06 W Z U H _ N Or- 0 d I- N Q 2 D: 3 EA SILENCER SR64 GRY IVE SEE G.C. TO COORD. FOR HANDICAP SIGNAGE SUPPLIED BY SIGNAGE VENDOR. Q = Q Z Z � Q Z w Q 7) _J -U (n Q 2 100A ENTRY DOOR & FRAME 3UPPLIED LAN ORD SHELL CONIR, AL M. H-2 J-2 S-1 1 G.C. TO COORD. W/ KEYBANK SIGNAGE CONTR. 100B ENTRY DOOR & FRAME SUPPLIED LAN ORD SHELL CONIR. ALL M. H-2 J-2 --- 1 102 CONFERENCE A 3'-0" x 7'-0" 1 3/4' SCWD PT STD 1 HM PT H-1 J-1 --- 7 103 WORK ROOM A 3'-0" x 7'-0" 1 3/4' SCWD PT STD 1 HM PT H-1 J-1 --- 2 104 WORK ROOM A 3'-0" x 7'-0" 1 3/4' SCWD PT STD 1 HM PT H-1 J-1 --- 2 105 WOMEN A 3'-0" x 7'-0" 1 3/4' SCWD PT 3/4' 1 HM PT H-1 -1 --- 6 G.C. TO COORD. W/ KEYBANK SIGNAGE CONTR. 106 MEN A 3'-0" x 7'-0" 1 3/4" SCWD PT 3/4" 1 HM PT H-1 J-1 6 G.C. TO COORD. W/ KEYBANK SIGNAGE CONTR. 107 JANITOR A 3'-0" x 7'-0" 1 3/4' SCWD PT 3/4" 1 HM PT H-1 J-1 --- 4 108 LOUNGESTD 2 109 ETD A 3'-0" x 7'-0" 1 3/4' SCWD PT STD 1 HM PT H-1 J-1 5 110 Not Used H-2 J-2 --- 8 1 1 1 ATM A (2)- 3'-6" x 7' 0"3/4' SCWD PT STD 11 HM PT H-1 J-1 --- 3 1 1 2 EXIT DOOR DOOR & FRAME $UPPLIED LAN LORD SHELL ON H-2 J-2 --- 8 EXIT ALARM LOCK COORDINATE W/ KEYBANK CONSTR. MGR. G.C. TO COORD. W/ KEYBANK SIGNAGE CONTR. HARDWARE SETS 3CB1 4.5 x 4.5 Checked by: 652 IVE HW SET. 01 ND10S RHO DOOR NUMBER: SCH 100A 1008 WS407CCV EACH TO HAVE: IVE 4 EA HINGE 3C81 4.5 X 4.5 NRP 630 IVE SR64 2 EA DEADLOCK MS1850S 628 ADA GRY IVE 2 EA IC MORTISE CYLINDER 20-091 EVEREST 626 SCH 1 EA SURFACE CLOSER 4111 SCNS 689 LCN PUSH/PUILL, THRESHOLD (AT 11010A ONLY), SWEEP AND GASKETING BY ALUMINUM DOOR VENDOR. SEE G.C. TO COORD. FOR LOGO AND OBC SIGNAGE DETAILS SUPPLIED BY SIGNAGE VENDOR HW SET: 02 DOOR NUMBER: 3CB1 4.5 X 4.5 101 103 109 EACH TO HAVE: 3 EA HINGE 3CB1 4.5 x 4.5 652 IVE 1 EA STOREROOM LOCK ND80RD RHO (EVEREST) 626 SCH MS1850S 1 EA SURFACE CLOSER 4011/4111 AS REQUIRED 689 LCN 1 EA OVERHEAD STOP 900S (AT 103) 630 GLY 1EA WALL BUMPER WS407CCV 630 IVE 1 EA PEEP HOLE 698 (VERIFY W/ CM IF NEEDED AT 103 626 IVE 20-091 EVEREST 3 EA SILENCER SR64 GRY IVE HW SET- 03 4111 SCNS DOOR NUMBER: 689 102 EACH TO HAVE: 6 EA HINGE 3CB1HW 4.5 x 4.5 NRP ONLY), SWEEP AND GASKETING 652 HAG 1EA CONST LATCHING BOLT F861T (3/4" THROW WITH 7/8" VERTICAL ADJUST) 626 IVE 1 EA STOREROOM LOCK ND80RD RHO (EVEREST) 626 1 EA DUMMY TRIM ND170 RHO AND OBC SIGNAGE DETAILS SUPPLIED 626 SCH VENDOR 2 EA OVERHEAD STOP 900S 630 GLY 2 EA SILENCER SR64 GRY IVE HW SET: 04 DOOR NUMBER: 104 EACH TO HAVE: 3 EA HINGE 3C81 4.5 x 4.5 652 IVE 1EA PASSAGE LATCH ND10S RHO 626 SCH 1 EA OVERHEAD STOP 900S 630 GLY 3 EA SILENCER SR64 GRY IVE HW SET. 05 DOOR NUMBER: 105 108 EACH TO HAVE: 3 EA HINGE 3CB1 4.5 x4.5 652 IVE 1EA STOREROOM LOCK ND80RD RHO (EVEREST) 626 SCH 1 EA WALL BUMPER WS407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE HW SET -06 DOOR NUMBER: 106 107 EACH TO HAVE: 3 EA HINGE 3CB1 4.5 x 4.5 652 IVE 1EA PRIVACY LOCK ND40S RHO 626 SCH 1 EA KICK PLATE 8400 10 X 2 LDW 630 IVE 1 EA WALL BUMPER WS407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE SEE G.C. TO COORD. FOR HANDICAP SIGNAGE SUPPLIED BY SIGNAGE VENDOR. HW SET: 07 DOOR NUMBER: 110 EACH TO HAVE: ALUM.STOREFRONT STANDARD COMMERCIAL GRADE DOOR SILL DETAILS 1/2" CLEAR TEMPERED LAMINATED SAFETY CLASS (SEE DWG # A-5.0) WEATHER STRIPPING - 1/2" CLEAR TEMPERED LAMINATED SAFETY GLASS MAX. 1/2" THRESHOLD HEIGHT & MUST MEET ADA REQMT'S NOTE: THRESHOLD WIDER THAN DOOR & MAX. 1/2" H. TO MEET ADAAG H.C. REQMT'S S1 TYPE S1 A1.0 3 EA HINGE 3CB1 4.5 x 4.5 Checked by: 652 IVE 1 EA PASSAGE LATCH ND10S RHO 826 SCH 1 EA WALL BUMPER WS407CCV 630 IVE 3 EA SILENCER SR64 GRY IVE HW SET: 08 DOOR NUMBER: 111 EACH TO HAVE: 4 EA HINGE 3CB1 4.5 X 4.5 NRP 630 IVE 2 EA DEADLOCK MS1850S 628 ADA 2 EA IC MORTISE CYLINDER 20-091 EVEREST 626 SCH 1 EA SURFACE CLOSER 4111 SCNS 689 LCN PUSH/PULL, THRESHOLD (AT 100A ONLY), SWEEP AND GASKETING BY ALUMINUM DOOR VENDOR. SEE G.C. TO COORD. FOR LOGO AND OBC SIGNAGE DETAILS SUPPLIED BY SIGNAGE VENDOR TYP MIN. 2'-4 3/4" 6" 8 BEARIN R. 0. R.O. EXTERIOR SCALE: NOT TO SCALE ALUMINUM DOOR DOOR JAMB FRAME W/ HINGE PLATES EXTERIOR SIDEWALK ALUMINUM THRESHOLD SET IN SEALANT ANCHOR TO ONE SIDE OF CONC. SLAB WHERE EXP. JOINT OCCURS NOTE: ANY ALUM. USED MUST NOT BE PLACED IN DIRECT CONTACT WITH DISSIMILAR METALS OR OTHER FINISH MATERIALS THAT ARE REACTIVE TO ALUMINUM, G.C. TO USE APPROPRIATE PAINT OR PRIMER OR SEALANTS WITH BACKER RODS TO SEPARATE THE CONTACT. G.C. MAY SUBSTITUTE ANY ALUM. METALS WITH OTHER PRE -FINISHED METALS THAT ARE CORROSION-RESISTENT MATERIALS AND MUST BE APPROVED BY ARCHITECT AND KEYBANK CONSTRUCTION MANAGER. NOTE: G.C. TO COORDINATE W/ LANDLORD SHELL CONTR. AT ATM FPR STRUCTURAL HEADER ABV. SURROUND. AND COORD. W/ SIGNAGE CONTR. G.C. TO VERIFY ST'L LINTEL W/ FLASH'G IS INSTALLED BY LANDLORD, IF NOT G.0 IS RESPONSIBLE TO INSTALL FLASHING. COORD. W. ARCHITECT. TYP. BLOCKED HEADER ® EACH OPN'G AS REQ'D TO FRAME ATM OPENING NOTES: 1. 4" MAXIMUM WALL THICKNESS REQUIRED FOR INSTALLATION OF #10731X DRIVE -UP A.T.M. DBL MT'L STUD FRAMING 0 EACH SIDE OF OPN'G TOP OF CURB DRIVEWAY LEVEL TYP. 2 1/2- MI -L STUD ® 16" O.C. BY LANDLORD CONTR. G.C. TO COORD. OPN'G SIZE. OPENING ELEVATION vocon DESIGN INC. 2450 Prospect Aven Cleveland, Ohio 4411 216 623-6800 p. 216 623-0410 f. vocon©vocon.com 2450 Prospect Ave. 1 s121e. 623-68 Cleveland, Ohio 44115216-623-0410 THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Strestsboro Road 330 659-6688 Ph. Richfield, Ohio 44286 330 659-6675 Fax I I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly registered Architect under the laws of the State of which governors this project. WARNING: per LAW No person may alter these documents unless person is, "or under the direct supervision of the licensed architect. Signature: Registration No: Date: S No. AR1410QO20 4 S T A T II 4 2004 Type III Branch Proposed New Construc#sn Carmel, IN REVISIONS: WE WE O Q) Q) U 0 O U _ W � U U� \� O 0 E O Ln O N /issued for Bid and Permit 12/30/03 A A A A 77 Drawn by: JAC Checked by: MJK Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: Floor Plan, Door Schedule, Details, Specs & General Notes Sheet Number: A=1 mO Original Date: December 16, 2003 WALL MC ABOVE C DWG'S) WALL TYPE LEGEND PROFILE AROUND GRID FOR SEPARATE GRID AREAS (WALL MOLDING) GYPSUM BOARD SOFFIT IBI WALL OR CEILING MOUNTED EXIT SIGN SUPPLY GRILLE SEE MECH. DWG'S RETURN GRILLE SEE MECH DWG'S EH RECESSED ELECT, HEAT UNIT IN CL'G SEE MECH DWG'S Z/\ a_ FIXTURE ELECTRICAL ENGINEERING DWGS FOR LIGHT FIXTURE SPECIFICATIONS INDICATES 4" SOUND BATTS INSULATION ABOVE CL'G & PARTITION DENOTES CEILING HEIGHT 2'x2'x5/8" LAY- IN CEILING BY ARMSTRONG. STYLE- DUNE, ITEM #1775 IN ARMSTRONG "SUPRAFINE" 9/16" WIDE SUSPENSION SYSTEM. PROVIDE SIZEMATIC BRACING & CLIPS AS REQUIRED BY LOCAL JURISDICTION GENERAL NOTES 1. ARCHITECTURAL REFLECTED CEILING PLANS ARE FOR THE PURPOSE OF INDICATING THE DESIGN INTENT ONLY. INDICATIONS OF HVAC DIFFUSERS, GRILLES, UNITS, ETC., ARE SHOWN ONLY FOR COORDINATION OF THE DESIGN INTENT. REFER TO ENGINEERING DRAWINGS FOR SPECIFIC DESIGN INFORMATION, 2. ALL DRYWALL CEILINGS AND SOFFITS TO BE PAINTED P-2 UNLESS OTHERWISE NOTED. SEE FINISH PLAN DWG #A-4.0 FOR PAINT SPECIFICATION 3. ALL SWITCHES TO BE TOGGLE TYPE - WHITE COLOR 4. ALL DEVICES THAT OCCUR IN MILLWORK PANELS SHALL BE COORDINATED W/ ARCHITECT TO COORDINATE DEVICE LOCATION. COLOR OF DEVICES IN P -LAM 1 AND 2 SHALL BE BROWN. DEVICES THAT OCCUR IN P -LAM 3 SHALL BE WHITE. 5. VERTICAL DIMENSIONS ARE ABOVE FINISHED SLAB A.F.S. ACOUSTICAL LAY -IN TILES, PATTERN RUNNING IN SAME DIRECTION, EXCEPT THOSE AREAS NOTED OTHERWISE ON REFLECTED CEILING PLANS, 6. CONTRACTOR TO COORDINATE INSTALLATION OF CEILING GRID W/ MECHANICAL, PLUMBING, AND ELECTRICAL PRIOR TO INSTALLING. CONTRACTOR TO NOTIFY ARCHITECT WHEN SUFFICIENT CLEARANCE "CAN NOT" BE MAINTAINED. 7. DIMENSIONED LIGHT FIXTURES ARE FROM FINISH FACE OF PARTITIONS TO CENTER LINE OF FIXTURE AND FROM CENTER LINE OF FIXTURE TO CENTERLINE OF FIXTURE. ALL FIXTURES SHALL BE INSTALLED IN CENTER TILE U.O.N. 8. ALL MULTIPLE SWITCH LOCATIONS ARE TO BE GANGED AND INSTALLED WITH A SINGLE FACE PLATE. 9. ALL V.A.V. BOXES AND ALL ITEMS REQUIRING ACCESS SHALL BE RELOCATED OUT OF GYPSUM BOARD CEILING U.O.N. 10. ANY DISCREPANCIES WITH LIGHT FIXTURES, SWITCHES, THERMOSTATS, DIFFUSERS AS TO LOCATION BETWEEN ARCHITECTURAL AND ENGINEERING DRAWINGS OR BETWEEN THE DRAWINGS AND EXISTING FIELD CONDITIONS SHALL BE CLARIFIED WITH ARCHITECT BEFORE PROCEEDING WITH INSTALLATION. 11. EXACT LOCATIONS OF THERMOSTATS SHALL BE IDENTIFIED BY GC AND VERIFIED IN FIELD BY KEY CONSTRUCTION MGR, INC. PRIOR TO INSTALLATION. ALL THERMOSTATS TO BE CENTERED ABOVE LIGHT SWITCH U.O.N. AND TO BE MOUNTED AT 48" A.F.F. TO CENTERLINE OF DEVICE UNLESS OTHERWISE NOTED. REFER TO ENGINEERING DRAWINGS FOR REQUIRED QUANTITY. 12. ACCESS PANELS SHALL BE INSTALLED AT ANY LOCATION REQUIRING FUTURE ACCESS, I.E. JUNCTION BOXES, PIPING VALVES, VALVE CONTROLS, ETC., WHETHER OR NOT INDICATED ON DRAWINGS. ANY ACCESS PANELS REQUIRED IN GYPSUM BOARD CEILING SHALL BE VERIFIED WITH ARCHITECT PRIOR TO INSTALLATION. 13. GC TO VERIFY AND COORDINATE SWITCH AND DIMMER CONTROL LOCATIONS WITH MILLWORK AND PROVIDE CUT OUT FOR FLUSH MOUNTED SWITCHES IN MILLWORK. 14. ALL LIGHT FIXTURES, SPRINKLER HEADS, AND ANY OTHER CEILING FIXTURES SHALL BE CENTERED IN THE 2'-0" X 2'-0" TILES. 15. FINAL EXIT SIGN AND EMERGENCY LIGHT LOCATIONS ARE SUBJECT TO THE APPROVAL OF THE LOCAL AUTHORITY AND FIELD INSPECTOR. 16. ALL SWITCHES LOCATED ON PARTITIONS ADJACENT TO DOOR SWINGING AGAINST PARTITION TO BE POSITIONED CLEAR OF DOOR SWING AND VISIBLE WHEN DOOR IS FULLY OPEN. 17. REFER TO FLOOR PLAN DWG #A-1,0 FOR INDICATION OF WALL TYPES. REFLECTED CEILING PLAN SCALE: 1/4" = 1'- 0" h G.C. TO PROVIDE SEAMLESS DRYWALL ACCESS HATCH AS REQ'D TO SERVICE UNIT CENTER UNIT IN ROOM vocon DESIGN INC. 2450 Prospect Aven Cleveland, Ohio 4411 216 623-6800 p. 216 623-0410 f. vocon®vocon.com 13 JT@h015����, 2450 Prospect Ave. 1 s121fr. 623-68 Cleveland, Ohio 44115216-623-0410 THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Strsetsboro Road 330859-6888 Ph. Richfield, Ohio 44288 330 859-8875 Fax I I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly registered Architect under the laws of the State of which governors this project. WARNING: per LAW No person may alter these documents unless person is, "or under the direct supervision of" the licensed architect. Signature: Registration No: Date: S C►f1E 0 4 2004 Type III Branch Proposed New Constructt en Carmel, IN O O O Q) Q) U 0 O O 4 U Cn O O E O Ln N O N REVISIONS: /Issued for Bid and Permit 12/30/03 Drawn by: JAC Checked by: MJK Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: Reflected Ceiling Plan and Notes Sheet Number: A=2m0 Original Date: December 16, 2003 r FLOORING PLAN "/ SCALE: 1/4" = 1'- 0" SOFFIT AND GYP. BOARD CEILING PAINT COLORS FINISH PLAN -'/ SCALE: 1/4"= 1'- 0" FINISH NOTES: 1 • CARPETED ROOMS TO HAVE 4" CARPET BASE 2. ALL PAINT TO WALLS TO BE AN EGGSHELL FINISH UNLESS OTHERWISE NOTED 3. ALL SAMPLES TO BE PROVIDED TO ARCHITECT FOR APPROVAL 4. SEE ELEVATIONS & DETAILS FOR LAMINATE DESIGNATION OF MILLWORK 5. ATTIC STOCK MATERIAL TO BE STORED ON SHELVING IN ETO ROOM FINISH SPECIFICATIONS NOTE: CONTRACTOR SHALL USE THE FOLLOWING ADHESIVES & PRIMERS TO BE USED TO INSTALL "BOLTA SANDSTONE" WALLCOVERING PRIMERS: 1) GIBSON-HOMANS DYNAMITE PROFESSIONAL WALLCOVERING PRIMER #735 HEAVY DUTY ACRYLIC WALLCOVERING PRIMER 2) ROMAN ADHESIVES PROFESSIONAL R-35 3) GOLDEN HARVEST BITE ALL -SURFACE WALLCOVERING PRIMER/SEALER 4) WILLIAM ZINSSER CO. Z-54 WALLCOVERING PRIMER ADHESIVES (CLAY BASED ONLY AND DO NOT WATER DOWN): 1) ROMAN ADHESIVES EXTRA STRENGTH VINYL ADHESIVE PRO -732 2) GIBSON-HOMANS DYNAMITE PROFESSIONAL WALLCOVERING ADHESIVES # 233 HEAVY DUTY CLAY WALLCOVERING ADHESIVE. FINISHES: FIBERGLASS REINFORCED PANELS GLASS Gl CLEAR GLASS TO OFFICE AND MEETING ROOMS FRP1 CITADEL ARCHITECTURAL PRODUCTS TEXTURED RFP 1/4" TEMPERED GLASS IN NATURAL MILL FINISH COLOR: WHITE ALUMINUM FRAMING SYSTEM RUN 48" WIDE PANELS HORIZONTALLY & FINISH EDGE W/ PANEL CAP GD 1/4- ETCHED AND SEALED TEMPERED GLASS IN ALUMINUM FRAME WITH NATURAL MILL FINISH PLASTIC LAMINATE (OCCURS AT BOTTOM OF WINDOW PANELS) ® PIONITE PLASTIC LAMINATE OR WILSONART PLASTIC LAMINATE PAINT JEWEL MAHOGANY/WY351-H/HI•BRITE FIGURED MAHOGANY 7040A (USE ONLY PIONITE P -LAM 1 WITH (USE ONLY WILSONART P -LAM 1 ALL INTERIOR PAINT TO BE SHERWIN WILLIAMS: PIONITE P -LAM 2) WITH WILSONART P -LAM 2) "HARMONY" EG-SHEL NO EXCEPTIONS COLORS TO MATCH SPECIFIED COLOR BELOW ® PIONITE PLASTIC LAMINATE OR WILSONART PLASTIC LAMINATE FORMAL MAHOGANY/WYO31/SUEDE WINDSOR MAHOGANY 7039-60 (USE ONLY PIONITE P -LAM 2 WITH (USE ONLY WILSONART P -LAM 2 PIONITE P -LAM 1) WITH WILSONART P -LAM 1) CDSHERMN WILLIAMS: RAFFIA BASKET 1113 WILSONART PLASTIC LAMINATE NATURAL NEBULA 4633-60 PD BENJAMIN MOORE: MOONLIGHT WHITE 2143-60 VINYL FLOORING P4 BENJAMIN MOORE: DEEP ROSE 2004-10 21 ARMSTRONG VINYL FLOORING COLOR: 51805 CAMEL BEIGE STYLE: 12"X12" IMPERIAL TEXTURE/STANDARD EXCELON PS BENJAMIN MOORE: MINK 2112-10 • ALL DOORS & FRAMES EXCEPT ALUMINUMV2 ARMSTRONG VINYL FLOORING COLOR: 31783 SUNFLOWER "TRANSLATIONS" SHEET VINYL W/ INTEGRAL 6" COVE BASE CARPET PORCELAIN STONE CROSSVILLE PORCELAIN STONE OR CREATIVE MATERIALS CORP. (✓ 1 BENTLEY CARPET CTl A675/STONEHENGE, 12" x 12" GRANIGLIATI ROMAN STONE ACCENT GROUT: BOSTIK FINDLEY DURBOUND 12 X 12 W/ MATTE FINISH WITH HIGH PERFORMANCE WITH HIGH PERFORMANCE BACKING COLOR: CHESTNUT GROUT: BOSTIK FINDLEY DURBOUND 12 WEEK LEAD TIME CROSS SHEEN -UPS COLOR: CHESTNUT CONTACT: JOYCE/DON CAVIN (740.549.0991) CONTACT: SCOTT BOCKETTI 518.452.9694 OCROSSVILLE CTD PORCELAIN STONE OR CREATIVE MATERIALS CORP. A790/13URGANDY SMOKE 12"x 12" GRANIGLIATI GRANATO FIELD GROUT: BOSTIK FINDLEY DURBOUND 12 X 12 W/ MATTE FINISH B 1 ALLSTATE: 4" RUBBER COVE BASE OR JOHNSONITE 4" RUBBER COVE BASE COLOR: CHESTNUT GROUT: BOSTIK FINDLEY DURBOUND COLOR: CARAMEL #15 COLOR: DESERT CAMEL #19 CROSS SHEEN - UPS COLOR: CHESTNUT (ROLL STOCK TYPICAL) (ROLL STOCK TYPICAL) CONTACT: SCOTT BOCKETTI (TO BE USED WITH V1) (TO BE USED WITH V1) 518.452.9694 BD ALLSTATE: 4" RUBBER COVE BASE OR JOHNSONITE 4" RUBBER COVE BASE (USE ONLY CREAVTIVE MATERIAL CORP. CTI COLOR: #09 COLOR: BURNT UMBER #63 W/ CREAVTIVE MATERIAL CORP. CT2) (ROLL STOCK TYPICAL) (ROLL STOCK TYPICAL) (TO BE USED WITH M1) (TO BE USED WITH M1) WALK -OFF MAT AFCO-USA B3 O CARPET BASE 4" CARPET M 1 AMERICAN FLOOR PRODUCTS Co., INC. BASE TO MATCH C1 STYLE: CM -1734 (TO BE USED WITH Cl) COLOR: CHARCOAL #07 CONTACT: (800) 342-0424 64 PORCELAIN STONE BASE 4" PORCELAIN STONE BASE TO MATCH CT2 MINI BLIND (TO BE USED WITH CT2) BL1 BALI 1" HORIZONTAL BLINDS (FRAME 1"x 1.5") 112 ALABASTER/FACTORY FINISHED ALUMINUM STANLEY ROPE CLEATS AT ALL BLIND LOCATIONS SIZE: 4 1/2" FINISH: US2C EDP#: 76 6485 'B3' BASE TRANSITI( STRIP PLAM BASE @ TELLER I 'C1' FLR'G 3 DETAIL —4. S C A L E: N.T.S. rA vocon DESIGN I NC. 2450 Prospect Aven Cleveland, Ohio 4411 216 623-6800 p. 216 623-0410 f. vocon@vocon.com M.9. 1 J[2@ 2450 Prospect Ave. 1 st2lffir. 623-6 Cleveland, Ohio 44115216-623-041 THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Strestsboro Road(330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fox I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly registered Architect under the laws of the State of which govemors this project. WARNING: per LAW No person may alter these documents unless person is, "or under the direct supervision of" the licensed architect. No: ✓Jf/ ` P� NQ. AR101Cf', T A T /41 .} 2004 Type III Branch Proposed New Construc# �n Carmel, IN 0 I 0 Q) Q) ME Ln N O N REVISIONS: Issued for Bid and Permit 12/30/03 Drawn by: JAC Checked by: MJK Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: Finish, Flooring Plans and Specifications Sheet Number: A-4. 0 Original Date: December 16, 2003 13" D. P -LAM WALL CAB. 4" BRUSHED ALUM. ARCH PULLS (P -LAM 3) PLAM-3 PRINTED STAND ON CASTERS (SEE DET.# G/A-8.0) NOTES: NEC MP -2 42" PLASMA SCREEN MONITOR WITH TILTING CEILING MOUNT NOTES: PDM -425-T PROVIDED BY AND WORK SURFACE AT 5' 6" INSTALLED BY CABLING VENDOR. G.C. TO TELLER MOUNTED AREA IS DIRECTLY E 3 PROVIDE BLOCKING. ON TOP OF SUPPLIED A7,0 EQUAL EQUAL DIEBOLD EQUIPMENT. 1 1/2"THICK X 24"D P -LAM - COUNTER TOP W/ PLAM SIDE SUPPORT AND 4" P -LAM BACK SPLASH INSTALL W/ SILICONE. (P -LAM 3) 1.) GENERAL CONTRACTOR TO VERIFY THE FINAL QUANTITY AND ALL REQUIRED FORT HOWARD ACCESSORIES W/ KEYBANK CONSTRUCTION MANAGER PRIOR TO ORDERING AND INSTALLING ANY ITEMS. 2.) G.C. TO USE MOISTURE RESISTANT GYP. BOARD IN RESTROOMS. 3.) WALL MOUNTED CABINET IN RESTRMS WILL BE USED FOR SUPPLIES ONLY AND NOT NEED TO BE ACCESSIBLE FOR H.C. BOBRICK 8165 SERIES MIRROR W/ S.S. CHANNEL FRAME MODEL# B-165 1824 SIZE: 18" x 24" #GOJ9502-01 SOAP 500m1 DISPENSER COLOR: SMOKE (SIZE: 11"435"x4.75") W/#GOJ9538-18 HAND SOAP AS MFG BY FORT HOWARD (REQ'D DIMENSIONS AS INDICATED) 8' KOHLER TRITON FAUCET W/ ADA APPROVED HANDLES. KOHLER MORNINGSIDE K-12634 WHEELCHAIR LAVATORY. COLOR: WHITE (OFFSET DRAIN AS REQ'D, INSULATE ALL EXPOSED SUPPLY AND DRAIN LINES PER ANSI) (REQ'D DIMENSIONS AS INDICATED) TOILET ROOM A7.OJ SCALE: 1/4"=1'-0" A TELLER AREA/WORK ROOM A7.0 SCALE: 1/4"=1'-0" NOTE: G.C. TO PRICE AS ALTER. AND VERIFY WITH KEYBANK CONSTR. MGR THE FOLLOWING #FHP578-93 COVERED 2 ROLL TISSUE DISPENSER, COLOR: STAINLESS STEEL (S/S) (SIZE: 12.75"x7"x6.25") W/ #FHP16121 2 -PLY TISSUE AS MFG BY FORT HOWARD #FHP576-10 OPEN 2 ROLL TISSUE DISPENSER, COLOR: METAL SIMILAR S/S (SIZE: 2.38"x10.5"x4.38") W/ #FHP145 1 -PLY TISSUE AS MFG BY FORT HOWARD #FHP 566-50 MULTIFOLD DISPENSER, COLOR: SMOKE (SIZE: 14.375"x11.75"x5.13") W/ #FHP202-04 FOLDED TOWEL & #FHP00887 FOLDED TOWEL AS MFG BY FORT HOWARD 30" HIGH, 13"D P -LAM WALL CAB. W/ 4" BRUSHED ALUM. ARCH. PULLS (P -LAM 3),� (MTG HT FROM BOTTOM OF CABINET: 60" AFF) #FHP 543-36 GREY ROLL TOWEL DISPENSER, COLOR: SMOKE (SIZE: 12"x11.81"x9.75") W/ Y.A 3 #FHP280-00 ROLL TOWEL & #FHP28055 ROLL TOWEL AS MFG BY FORT HOWARD (REQ'D A7.0 DIMENSIONS AS INDICATED) Iol BOBRICK B165 SERIES MIRROR W/ S.S. r-wczJ CHANNEL FRAME. (SEE ELEV. NOTES 2'-6" F/A7.0) BOBRICK MODEL* B6206, CONCEALED MO 1 1/2" DIAM., STAINLESS STEEL WITH SATIN 36" FINISH (REQ'D DIMENSIONS AS INDICATED) 5 MIN. 5' KOHLER HIGHCLIFF TOILET (SEAT HT TO BE 1 -19-AFF) 48" L. 36" V 40" MAX, 36" #FHP580-50 GIANT ROLL TISSUE DISPENSER, COLOR: SMOKE 16"T018" (SIZE: 11"x10.50"x5") W/ #FHP137-02 JR ROLL TISSUE AS MFG BY FORT HOWARD (REQ'D DIMENSIONS AS INDICATED) 4" WALL BASE PER FLOORING PLAN (SEE - FINISH SCHEDULE ON SHEET A4.0) F1 TOILET ROOM A7.0 SCALE: 1/4"=1'-0" NOTE: BACKSPLASH OCCURS ONLY ON WET AREAS. FOR OTHER AREAS SCRIBE COUNTER TO TALL & SEAL W/ CLEAR COLOR SILICONE SEALANT DRAWER CONSTRUCTION TYP. 5/8" LAMINATED FACE, 1/2" SEALED BIRCH PLYWD SIDES AND BACK, 1/4" WT. 2" MELAMINE BOTTOM. 4" P -LAM BACKSPLASH FIELD INSTALL SILICONE P -LAM TOP W/ 1-1/2" LAMINATE NOSE LAMINATE EDGE OF BLOCKING TYP. BRUSHED ALUM ARCH. 4" RADIUS PULLS P -LAM DOOR, 5/8" MDF. PROVIDE EURO. 176 - DEG. S -C HINGES 5/8" MELAMINE WITH LAMINATED EDGEB P -LAM INTERIOR W/ SUPPORT CLIP HOLES 2" O.C. 4" VINYL COVE BASE J I�I J 6" K wcz r - L `P-2 J A7.0 4" P -LAM BACK SPLASH BLOCKING AS REQUIRED SUPPLY LINE AS REQ'D SCALE: 114"=1'-0" �/ INSTALL W/ SILICONE (P -LAM 24"W PLAM SHELF & END SCALE: 1/4"=1'-0" ADA APPROVED GOOSENECK 1/4"=1'-0" 2'-6" PANEL (P-LAM3) r -P-4 J /j r -P-4 J Q) a SINGLE BOWL KITCHEN SINK REQUIRED LU Lu U 13" D. P -LAM WALL CAB. W/ 4" 1 1/2" P -LAM COUNTER TOP COAT ROD 1" P -LAM SUPPORT AS REQUIRED. A7.0 XJ4 r- (P -LAM 3) U� (P -LAM 3) A7.0 G.C. TO SUPPLY GRAINGER-CITADEL G.E. MICROWAVE = O 1 Ln 2' 0" r wc2 -? A7.0 A7.0 COLOR: WHITE Eft N 24" D. P -LAM BASE CAB. W/ 4" GRAINGERM 4T X 30 MANUF.: / BRUSHED ALUM. ARCH PULLS EDSAL MANUR M CL5101 5'-6" F-1r-IF--IF-1r-1F-1F-1F-717 II II IF-IF-�F-1 II II II II II II II 2-6 4" P -LAM BACK SPLASH (P -LAM 3) (P -LAM 3) \ \ / / I II II 10' INSTALL W/ SILICONE \ / 3' 6" I I I I I I I I I I I I I \ / -� PLAN (SEE FINISH SCHEDULE I II II II II II II II II II II I 1 ON SHEET A4.0) ON SHEET A4.0) - KITCHEN - LOCKERS/COATS 1 1/2"THICK X 24"D P -LAM - COUNTER TOP W/ PLAM SIDE SUPPORT AND 4" P -LAM BACK SPLASH INSTALL W/ SILICONE. (P -LAM 3) 1.) GENERAL CONTRACTOR TO VERIFY THE FINAL QUANTITY AND ALL REQUIRED FORT HOWARD ACCESSORIES W/ KEYBANK CONSTRUCTION MANAGER PRIOR TO ORDERING AND INSTALLING ANY ITEMS. 2.) G.C. TO USE MOISTURE RESISTANT GYP. BOARD IN RESTROOMS. 3.) WALL MOUNTED CABINET IN RESTRMS WILL BE USED FOR SUPPLIES ONLY AND NOT NEED TO BE ACCESSIBLE FOR H.C. BOBRICK 8165 SERIES MIRROR W/ S.S. CHANNEL FRAME MODEL# B-165 1824 SIZE: 18" x 24" #GOJ9502-01 SOAP 500m1 DISPENSER COLOR: SMOKE (SIZE: 11"435"x4.75") W/#GOJ9538-18 HAND SOAP AS MFG BY FORT HOWARD (REQ'D DIMENSIONS AS INDICATED) 8' KOHLER TRITON FAUCET W/ ADA APPROVED HANDLES. KOHLER MORNINGSIDE K-12634 WHEELCHAIR LAVATORY. COLOR: WHITE (OFFSET DRAIN AS REQ'D, INSULATE ALL EXPOSED SUPPLY AND DRAIN LINES PER ANSI) (REQ'D DIMENSIONS AS INDICATED) TOILET ROOM A7.OJ SCALE: 1/4"=1'-0" A TELLER AREA/WORK ROOM A7.0 SCALE: 1/4"=1'-0" NOTE: G.C. TO PRICE AS ALTER. AND VERIFY WITH KEYBANK CONSTR. MGR THE FOLLOWING #FHP578-93 COVERED 2 ROLL TISSUE DISPENSER, COLOR: STAINLESS STEEL (S/S) (SIZE: 12.75"x7"x6.25") W/ #FHP16121 2 -PLY TISSUE AS MFG BY FORT HOWARD #FHP576-10 OPEN 2 ROLL TISSUE DISPENSER, COLOR: METAL SIMILAR S/S (SIZE: 2.38"x10.5"x4.38") W/ #FHP145 1 -PLY TISSUE AS MFG BY FORT HOWARD #FHP 566-50 MULTIFOLD DISPENSER, COLOR: SMOKE (SIZE: 14.375"x11.75"x5.13") W/ #FHP202-04 FOLDED TOWEL & #FHP00887 FOLDED TOWEL AS MFG BY FORT HOWARD 30" HIGH, 13"D P -LAM WALL CAB. W/ 4" BRUSHED ALUM. ARCH. PULLS (P -LAM 3),� (MTG HT FROM BOTTOM OF CABINET: 60" AFF) #FHP 543-36 GREY ROLL TOWEL DISPENSER, COLOR: SMOKE (SIZE: 12"x11.81"x9.75") W/ Y.A 3 #FHP280-00 ROLL TOWEL & #FHP28055 ROLL TOWEL AS MFG BY FORT HOWARD (REQ'D A7.0 DIMENSIONS AS INDICATED) Iol BOBRICK B165 SERIES MIRROR W/ S.S. r-wczJ CHANNEL FRAME. (SEE ELEV. NOTES 2'-6" F/A7.0) BOBRICK MODEL* B6206, CONCEALED MO 1 1/2" DIAM., STAINLESS STEEL WITH SATIN 36" FINISH (REQ'D DIMENSIONS AS INDICATED) 5 MIN. 5' KOHLER HIGHCLIFF TOILET (SEAT HT TO BE 1 -19-AFF) 48" L. 36" V 40" MAX, 36" #FHP580-50 GIANT ROLL TISSUE DISPENSER, COLOR: SMOKE 16"T018" (SIZE: 11"x10.50"x5") W/ #FHP137-02 JR ROLL TISSUE AS MFG BY FORT HOWARD (REQ'D DIMENSIONS AS INDICATED) 4" WALL BASE PER FLOORING PLAN (SEE - FINISH SCHEDULE ON SHEET A4.0) F1 TOILET ROOM A7.0 SCALE: 1/4"=1'-0" NOTE: BACKSPLASH OCCURS ONLY ON WET AREAS. FOR OTHER AREAS SCRIBE COUNTER TO TALL & SEAL W/ CLEAR COLOR SILICONE SEALANT DRAWER CONSTRUCTION TYP. 5/8" LAMINATED FACE, 1/2" SEALED BIRCH PLYWD SIDES AND BACK, 1/4" WT. 2" MELAMINE BOTTOM. 4" P -LAM BACKSPLASH FIELD INSTALL SILICONE P -LAM TOP W/ 1-1/2" LAMINATE NOSE LAMINATE EDGE OF BLOCKING TYP. BRUSHED ALUM ARCH. 4" RADIUS PULLS P -LAM DOOR, 5/8" MDF. PROVIDE EURO. 176 - DEG. S -C HINGES 5/8" MELAMINE WITH LAMINATED EDGEB P -LAM INTERIOR W/ SUPPORT CLIP HOLES 2" O.C. 4" VINYL COVE BASE 1 BASE CABINET DETAIL A7,O SCALE: N.T.S. ADA APPROVED FAUCET & STAINLESS-8� SINK. SEE PLUMING FIXTURE SCHEDULE 4" P -LAM BACKSPLASH FIELD INSTALLEE�- SILICONE F.R. WD BLOCKING AS REQ'D P -LAM TOP W/ 1-1/2" LAMINATE NOSE WRAP ALL EXPOSED PIPES W/ 1" INSULA SAFETY COVER. LAMINATE EDGE OF BLOCKING TYP. BRUSHED ALUM ARCH. 4" RADIUS PULLS P -LAM DOOR, 5/8" MDF. PROVIDE EURO. 1 DEG. S -C HINGES P -LAM INTERIOR 4" VINYL COVE BASE - r-WC2 J KN DIMENSIONAL KEY - WALL ----MOUNTED MERCHANDISING BY KEY VENDOR - 1 1/2" P -LAM COUNTER TOP (P -LAM 3) DIEBOLD EQUIPMENT BY OWNER 4" WALL BASE PER FLOORING PLAN (SEE FINISH SCHEDULE ON SHEET A4.0) N CV ii B WORK ROOM A7�OSCALE: 1/4"=1'-0" 13" D. P -LAM WALL CAB. W/ 4" BRUSHED ALUM. ARCH PULLS (P -LAM 3) 1 1/2" P -LAM COUNTER TOP & END PANEL (P -LAM 3) 4" WALL BASE PER FLOORING PLAN (SEE FINISH SCHEDULE ON SHEET A4.0) COPY/FAX AREA A7.0 SCALE: 1/4"=1'-0" ACOUSTICAL LAY -IN CEILING (SEE REFLECTED CL'G PLAN) GYP. BOARD SOFFIT KEY- PIN MOUNTED BRUSHED S.S. MERCHANDISING BY KEY VENDOR. (CENTERED ON WALL) PLAM-1 MERCHANDISING NICHE, 7' W X T-2" H W/ (3) EQUALLY G ACCENT LOGO WALL A7.0 SCALE: 1/2"=1'-0" NOTE: EXTEND FLOORING BELOW SINK SEE FINISH DWG NOTE: FOR ALL CEILING HEIGHTS SEE REFL. CLG. PLAN TYP. 2 1/2", 25 GA. MT'L STUD GLUE MOUNTED CARPET 16" O.C. CARPET CRUSH LINE SCREED LATEX FILL; BUILD UP AS REQ'D CERAMIC TILE TO ALIGN CARPET FFWITH TOP OF CR SCREED LINE p D D 24" WN. (N.T.S.) p 01 D D D D D D CONCRETE SLAB 8 FLOORING TRANSITION DETAIL A7.O SCALE: N.T.S. (4) - 12 GAUGE WIRES 90 ° APART E TIED TO MAIN TEE WITHIN 2" OF CROSS TEE. 12'-0" O.C. EA. WAY 6'-0" FROM WALL OV VERTICAL CHANNEL TO - STRUCTURE AT 12'-0" EA. WAY 6'-0" FROM WALL 4'-0" O.C. CEILING TILE SUSPENSION 11 DETAIL A7.O SCALE: N.T.S. SCALE: N.T.S. EXTEND GYP. BD. MIN. 6" ABOVE CLG EXTEND STUDS TO STRUCT. ABOVE. PROVIDE DIAGONAL BRACING @ 4'-0" O.C. MAX. /ACOUSTICAL CLG. TILE g�a �z >w 0 1/2" GYP. BD. (TYP.) C.B. SOFFIT/ CEILING TILE DETAIL SCALE: N.T.S. FASTEN TO STRUCTURE WITH 200# MIN. PULLOUT WITH SAFETY FACTOR OF 2 12 GA. WIRE @ 4'-0" O.C. @ MAIN TEE. FASTEN TO STRUCTURE WITH 200# PULLOUT MIN. EXPOSED CROSS TEE XPOSED MAIN TEE ACOUSTICAL TILE 13" D. P -LAM WALL CAB. W/ 4" BRUSHED ALUM. ARCH PULLS (P -LAM 3) CCTV 24x24 - I�I J NOTE: K G.E. REFRIGERATOR L `P-2 J A7.0 4" P -LAM BACK SPLASH BLOCKING AS REQUIRED SUPPLY LINE AS REQ'D 1 BASE CABINET DETAIL A7,O SCALE: N.T.S. ADA APPROVED FAUCET & STAINLESS-8� SINK. SEE PLUMING FIXTURE SCHEDULE 4" P -LAM BACKSPLASH FIELD INSTALLEE�- SILICONE F.R. WD BLOCKING AS REQ'D P -LAM TOP W/ 1-1/2" LAMINATE NOSE WRAP ALL EXPOSED PIPES W/ 1" INSULA SAFETY COVER. LAMINATE EDGE OF BLOCKING TYP. BRUSHED ALUM ARCH. 4" RADIUS PULLS P -LAM DOOR, 5/8" MDF. PROVIDE EURO. 1 DEG. S -C HINGES P -LAM INTERIOR 4" VINYL COVE BASE - r-WC2 J KN DIMENSIONAL KEY - WALL ----MOUNTED MERCHANDISING BY KEY VENDOR - 1 1/2" P -LAM COUNTER TOP (P -LAM 3) DIEBOLD EQUIPMENT BY OWNER 4" WALL BASE PER FLOORING PLAN (SEE FINISH SCHEDULE ON SHEET A4.0) N CV ii B WORK ROOM A7�OSCALE: 1/4"=1'-0" 13" D. P -LAM WALL CAB. W/ 4" BRUSHED ALUM. ARCH PULLS (P -LAM 3) 1 1/2" P -LAM COUNTER TOP & END PANEL (P -LAM 3) 4" WALL BASE PER FLOORING PLAN (SEE FINISH SCHEDULE ON SHEET A4.0) COPY/FAX AREA A7.0 SCALE: 1/4"=1'-0" ACOUSTICAL LAY -IN CEILING (SEE REFLECTED CL'G PLAN) GYP. BOARD SOFFIT KEY- PIN MOUNTED BRUSHED S.S. MERCHANDISING BY KEY VENDOR. (CENTERED ON WALL) PLAM-1 MERCHANDISING NICHE, 7' W X T-2" H W/ (3) EQUALLY G ACCENT LOGO WALL A7.0 SCALE: 1/2"=1'-0" NOTE: EXTEND FLOORING BELOW SINK SEE FINISH DWG NOTE: FOR ALL CEILING HEIGHTS SEE REFL. CLG. PLAN TYP. 2 1/2", 25 GA. MT'L STUD GLUE MOUNTED CARPET 16" O.C. CARPET CRUSH LINE SCREED LATEX FILL; BUILD UP AS REQ'D CERAMIC TILE TO ALIGN CARPET FFWITH TOP OF CR SCREED LINE p D D 24" WN. (N.T.S.) p 01 D D D D D D CONCRETE SLAB 8 FLOORING TRANSITION DETAIL A7.O SCALE: N.T.S. (4) - 12 GAUGE WIRES 90 ° APART E TIED TO MAIN TEE WITHIN 2" OF CROSS TEE. 12'-0" O.C. EA. WAY 6'-0" FROM WALL OV VERTICAL CHANNEL TO - STRUCTURE AT 12'-0" EA. WAY 6'-0" FROM WALL 4'-0" O.C. CEILING TILE SUSPENSION 11 DETAIL A7.O SCALE: N.T.S. SCALE: N.T.S. EXTEND GYP. BD. MIN. 6" ABOVE CLG EXTEND STUDS TO STRUCT. ABOVE. PROVIDE DIAGONAL BRACING @ 4'-0" O.C. MAX. /ACOUSTICAL CLG. TILE g�a �z >w 0 1/2" GYP. BD. (TYP.) C.B. SOFFIT/ CEILING TILE DETAIL SCALE: N.T.S. FASTEN TO STRUCTURE WITH 200# MIN. PULLOUT WITH SAFETY FACTOR OF 2 12 GA. WIRE @ 4'-0" O.C. @ MAIN TEE. FASTEN TO STRUCTURE WITH 200# PULLOUT MIN. EXPOSED CROSS TEE XPOSED MAIN TEE ACOUSTICAL TILE 13" D. P -LAM WALL CAB. W/ 4" BRUSHED ALUM. ARCH PULLS (P -LAM 3) NOTES: 1.) ADA REQ'S THAT KIT. SINK BASE CAB. BE ACCESSIBLE W/ MIN. 36"W FLOOR CLEAR. (FINISHED FLR SHALL EXTEND UNDER COUNTER TO WALL) 2.) G.C. TO USE MOISTURE RESISTANT GYP. BOARD AT ALL WET AREAS IN THE KITHCEN. NOTES: 1.) G.C. TO USE MOISTURE RESISTANT GYP. BOARD AT ALL WET AREAS IN JANITOR'S CLOSET. SPACED MERCHANDISE FIXTURES. (FIXTURES PROVIDED BY KEY BANK HEAVY-DUTY BRACKET VENDOR.) (CENTERED ON (TYPICAL) W1 SHELF CLIPS WALL) 12" D, 1" THICK MELAMI - 11 r -P-2 J -° SHELF (WHITE COLOR) QUANTITY - 2 r -71F (PROVIDE BLOCKING FOR 7 1 A.H.D. I I A.T.M. I ALL SHELVING) I II 4" WALL BASE PER FLOORI PLAN (SEE FINISH SCHEDUI 1 I I ON SHEET A4.0) 4" H BASE (PLAM-1) NOTE: VERIFY FINAL LAYOUT OF SHELVING W/ LOCAL KEY MANAGER CCTV 24x24 - G.C. TO SUPPLY J NOTE: K G.E. REFRIGERATOR L `P-2 J A7.0 4" P -LAM BACK SPLASH BLOCKING AS REQUIRED SUPPLY LINE AS REQ'D SCALE: 114"=1'-0" A70 INSTALL W/ SILICONE (P -LAM 24"W PLAM SHELF & END SCALE: 1/4"=1'-0" ADA APPROVED GOOSENECK 1/4"=1'-0" 3) PANEL (P-LAM3) FAUCET W/ STAINLESS STEEL Q) a SINGLE BOWL KITCHEN SINK REQUIRED LU Lu U 13" D. P -LAM WALL CAB. W/ 4" 1 1/2" P -LAM COUNTER TOP COAT ROD 1" P -LAM SUPPORT AS REQUIRED. A7.0 XJ4 r- (P -LAM 3) U� (P -LAM 3) A7.0 G.C. TO SUPPLY GRAINGER-CITADEL G.E. MICROWAVE = O 1 Ln UNASSEMBLED LOCKERS COLOR: WHITE Eft N 24" D. P -LAM BASE CAB. W/ 4" GRAINGERM 4T X 30 MANUF.: BRUSHED ALUM. ARCH PULLS EDSAL MANUR M CL5101 5'-6" 2-6 4" P -LAM BACK SPLASH (P -LAM 3) (P -LAM 3) COLOR: TAN \ / / 10' INSTALL W/ SILICONE 5'-4" 4" WALL BASE PER FLOORING 4" WALL BASE PER FLOORING PLAN (SEE FINISH SCHEDULE PLAN (SEE FINISH SCHEDULE (P -LAM 3) ON SHEET A4.0) ON SHEET A4.0) - KITCHEN - LOCKERS/COATS D A7.0 Cr.AI F 1/d"c 1' -fl" NOTES: 1.) ADA REQ'S THAT KIT. SINK BASE CAB. BE ACCESSIBLE W/ MIN. 36"W FLOOR CLEAR. (FINISHED FLR SHALL EXTEND UNDER COUNTER TO WALL) 2.) G.C. TO USE MOISTURE RESISTANT GYP. BOARD AT ALL WET AREAS IN THE KITHCEN. NOTES: 1.) G.C. TO USE MOISTURE RESISTANT GYP. BOARD AT ALL WET AREAS IN JANITOR'S CLOSET. SPACED MERCHANDISE FIXTURES. (FIXTURES PROVIDED BY KEY BANK HEAVY-DUTY BRACKET VENDOR.) (CENTERED ON (TYPICAL) W1 SHELF CLIPS WALL) 12" D, 1" THICK MELAMI - 11 r -P-2 J -° SHELF (WHITE COLOR) QUANTITY - 2 r -71F (PROVIDE BLOCKING FOR 7 1 A.H.D. I I A.T.M. I ALL SHELVING) I II 4" WALL BASE PER FLOORI PLAN (SEE FINISH SCHEDUI 1 I I ON SHEET A4.0) 4" H BASE (PLAM-1) NOTE: VERIFY FINAL LAYOUT OF SHELVING W/ LOCAL KEY MANAGER LOUNGE FIXTURES/APPLIANCES NOTES: 1. ALL FIXTURES/APPLIANCES, RELATED ACCESSORIES AND FASTENING DEVICES TO BE SUPPLIED AND INSTALLED BY CONTRACTOR, UNLESS NOTED OTHERWISE. 2. CONTRACTOR TO SUPPLY AND INSTALL ALL BLOCKING PER MANUFACTURER'S SPECIFICATIONS. 3. CONTRACTOR TO SUPPLY AND INSTALL ALL NECESSARY ELECTRICAL AND/OR PLUMBING CONNECTIONS FOR COMPLETE INSTALLATION PER MANUFACTURER'S SPECIFICATIONS. 4. ALL FIXTURES SHALL CONFORM TO AND BE INSTALLED AT HEIGHTS IN ACCORDANCE WITH AMERICANS WITH DISABILITIES ACT (A.D.A./ANSI A117.1-1992) AND APPLICABLE STATE REGULATIONS. 5. SUBSTITUTE FIXTURES ARE NOT ALLOWED, ALL FIXTURES ARE AS SPECIFIED. LOCATION OF BACK FLOW 6 GALLON HOT WATER TANK PREVENTION WATER HEATER PLATFeRM BACK FLOW PREVENTION (SEE MECHANICAL r P-2 J r P-2 J DRAWINGS) 8' 8' 12" D, 1" THICK MELAMINE + + + + + SHELF (WHITE COLOR) + + MOP HANGER + + QUANTITY - 4 4' + FRP BOARD + + + 4' FRP BOARD + + + MOP SINK + + + 4" WALL BASE PER FLOORING 4" WALL BASE PER FLO RING DU PLAN (SEE FINISH SCHEDULE PLAN (SEE FINISH SCHL ON SHEET A4.0) ON SHEET A4.0) H ATM G.C. TO SUPPLY J NOTE: K G.E. REFRIGERATOR L G.C. TO INSTALL WATER A7.0 COLOR: (WHITE) BLOCKING AS REQUIRED SUPPLY LINE AS REQ'D SCALE: 114"=1'-0" A70 SCALE: 1/4"=1'-0" FOR REFRIG. SCALE: 1/4"=1'-0" ADA APPROVED GOOSENECK 1/4"=1'-0" FIRE RETARDANT BLOCKING AS > FAUCET W/ STAINLESS STEEL Q) a SINGLE BOWL KITCHEN SINK REQUIRED LU Lu U 13" D. P -LAM WALL CAB. W/ 4" P-2 J 1" P -LAM SUPPORT AS REQUIRED. BRUSHED ALUM. ARCH PULLS r- 3 U� (P -LAM 3) A7.0 G.C. TO SUPPLY G.E. MICROWAVE / O / Ln \ COLOR: WHITE N 2-6 4" P -LAM BACK SPLASH (P -LAM 3) \ / / 10' INSTALL W/ SILICONE a 16" 1 1/2" P -LAM COUNTER TOP (P -LAM 3) 24" D. P -LAM BASE CAB. W/ 4" 2'-10" BRUSHED ALUM. ARCH PULLS i M (P -LAM 3) 1 2 4" WALL BASE PER FLOORING A7.0 A7.0 PLAN (SEE FINISH SCHEDULE ON SHEET A4.0) KITCHEN -SINK AREA E A7.0 SCALE: 1/4"=1'-0" LOUNGE FIXTURES/APPLIANCES NOTES: 1. ALL FIXTURES/APPLIANCES, RELATED ACCESSORIES AND FASTENING DEVICES TO BE SUPPLIED AND INSTALLED BY CONTRACTOR, UNLESS NOTED OTHERWISE. 2. CONTRACTOR TO SUPPLY AND INSTALL ALL BLOCKING PER MANUFACTURER'S SPECIFICATIONS. 3. CONTRACTOR TO SUPPLY AND INSTALL ALL NECESSARY ELECTRICAL AND/OR PLUMBING CONNECTIONS FOR COMPLETE INSTALLATION PER MANUFACTURER'S SPECIFICATIONS. 4. ALL FIXTURES SHALL CONFORM TO AND BE INSTALLED AT HEIGHTS IN ACCORDANCE WITH AMERICANS WITH DISABILITIES ACT (A.D.A./ANSI A117.1-1992) AND APPLICABLE STATE REGULATIONS. 5. SUBSTITUTE FIXTURES ARE NOT ALLOWED, ALL FIXTURES ARE AS SPECIFIED. LOCATION OF BACK FLOW 6 GALLON HOT WATER TANK PREVENTION WATER HEATER PLATFeRM BACK FLOW PREVENTION (SEE MECHANICAL r P-2 J r P-2 J DRAWINGS) 8' 8' 12" D, 1" THICK MELAMINE + + + + + SHELF (WHITE COLOR) + + MOP HANGER + + QUANTITY - 4 4' + FRP BOARD + + + 4' FRP BOARD + + + MOP SINK + + + 4" WALL BASE PER FLOORING 4" WALL BASE PER FLO RING DU PLAN (SEE FINISH SCHEDULE PLAN (SEE FINISH SCHL ON SHEET A4.0) ON SHEET A4.0) H ATM CLOSET J JANITOR'S K JANITOR'S L JANITOR'S A7.0 BLOCKING AS REQUIRED A70 SCALE: 114"=1'-0" A70 SCALE: 1/4"=1'-0" A7.0 SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" MILLWORK NOTES: - MILLWORK CONTR. TO USE AWI STANDARDS FOR PREMIUM GRADE CONSTRUCTION OF ALL WALL & BASE CABINET DETAILS. - CONTR. TO PROVIDE FIRE RETARD. BLK'G IN ALL CONCEALED WALLS. 24" COORDINATE W/ MILLWORK CONTRACTOR ta^ CONTRACTOR TO PROVIDE FIRE RETARD BLOCKING AS REQUIRED TYP. GYP. BD WOOD BLOCKING PAINTED TO MATCH 6" x 20GA. CONTINUOUS METAL REINFORCING '0/- P -LAM 5/8" MDF DOOR W/ 90 DEG. S -C HINGE PROVIDE FIRE RETARDANT WOOD BLOCKING (2) ADJ. 5/8" WHITE MELAMINE SHELVES W/ AS REQUIRED LAMINATED EDGE NOT LONGER THAN 3' 1 1/4" CHROME ROD CENTER SUPPORT 5/8" MELAMINE CABINET W/ SUPPORT CLIP ALLOWED ONLY FOR DISTANCE OF GREATER HOLES AT 2" O.C. THAN 4'-0" VERIFY W/ ARCHITECT BRUSHED ALUM ARCH. 4" RADIUS PULLS 6" x 20GA. CONTINUOUS METAL REINFORCING 3/4" MELAMINE SHELF W/ PLAM3 - 3 1/2" FINISH BOTT & TOP OF CAB. W/ LAMINANT NOSING 3 WALL CABINET DETAIL 4 COAT RACK DETAIL A7.0 SCALE: N.T.S. A7,0 SCALE: N.T.S. EXPOSED MAIN TEE ACOUSTICAL TILE CROSS TEE OR MAIN R CUT & RIVET FACE OF FINISHED WAI CEILING TILE TERMINATION @ 10 WALL DETAIL A7.O SCALE: N.T.S. 2-1/2" METAL STUDS, 25 GA. TO STRUCTURE @ 16" O.C. CONTINUOUS FLOUR. STRIP LIGHT SEE ELECT. PLANS FOR DETAILS 1" AIR SPACE ACOUSTICAL CEILING ALIGN W/ CEILING 5/8" GYP. BD O/ 2-1/2" METAL STUDS 1/2"x1/2" MINI-PARACUBE SPECULAR LOUVER BY ELECT. CONTRACTOR (SEE ELEC DWG'S) 12 LIGHT COVE DETAIL A7.O SCALE: N.T.S. E: SEE REFLECTED CL' N DWG FOR SPECIFICA ( WALL MOLDING (20" ® BACK TELLER COUNTER) 24" VARIES NOTE: CONTR. TO SCRIBE COUNTER TO WALL & SEAL W/ SEALANT (CLEAR COLOR) PLAM3 1-1/4" P -LAM TOP W/ LAM. NOSE 12" 12" HOLD (P -LAM 3) ww LL U a CO w ¢ Proposed New FIRE RETARDANT WOOD I SEE FLOOR PLAN FOR WALL TYPE O Ei Z BLOCKING AS REQUIRED > li = U) ¢ O Q) FIRE RETARDANT BLOCKING AS > a It Q) a U REQUIRED LU Lu U a rn� > LL J w w 1" P -LAM SUPPORT AS REQUIRED. 5/8" GYP. BD. v)u U� vwi 3.. SEE ELEVATIONS FOR LOCATIONS 4" CARPET BASE AT CARPETED O wq ¢ >- -v O 04 J J I- agU a ;a LU 2 U = U_ Z ¢ 5 WORK SURFACE DETAIL A] SCALE: N.T.S. TYP. 2 1/2", 25 G, STUD ® 16" O.C. 1/2- GYP. SOFFIT REFLECTED CEILING 1 /4"x1 /4" BLACK i REVEAL 1/2- MDF W/ PLAK OVER 5/8" GYP. BI 7", 25 GA. MT'L S- 16" O.C. TYP. 5/8" GYP. BC SPACKLED, SANDEC PRIMED READY TO RECEIVED PLAM PA LOCKED MITER (NO GAPS) 1 /4"x1 /4" BLACK REVEAL AREAS / DIRECT GLUE CARPET !j- , L VB -1 VINYL BASE COVED AT ALL HARD SURFACES 6 WALL BASE DETAIL A7.O SCALE: N.T.S. NOTE: EXTEND STUD TO STRUCT FRAMING ® 48" O.C. W/ DIAG. BRACING STOP 2 1/2" STUD W/ GYP. BD. EXTEND GYP. BD. MIN. 6" ABV. CEILING SEE REFLECTED CEILING PLAN FOR CONE. CEILING HEIGHT TYP. 5/8" GYP. BD. SEE FINISH PLAN FOR WALL FINISHES 1/4" MDF. W/ PLAM (INSIDE NICHE ONLY) OVER 5/8" GYP. BD. MERCHANDISING SIGNS BY KEY VENDOR NICHE SECTION DETAIL 13 FEATURE WALL A7.O SCALE: N.T.S. FILL WALL W/ SOUND BATT. INSUL. 2 1/2", 25 GA. MT'L STUD ® 16" O.C. SEE FINISH PLAN DWG FOR BASE TYPE @ CONF. RM 1/4%1/4- BLACK ACCENT REVEAL ® EDGE BETWEEN PLAM PANEL & GYP. BD. SOUND BATTS INSULATION SEE REFLECTED CEILING PLAN EXTEND GYP. BD. MIN. 6" ABV, CEILING SEE CL'G PLAN FOR HEIGHT tL 5/8" GYP. BD. 3 5/8" METAL STUDS 25 GA. 16" O.C. SECURED TO CEILING TYPICAL INTERIOR WALL @ CEILING DETAIL A7.0SCALE: N.T.S. 17 SEE DET. #13/A-7.0 FOR SECTION 1/2" MDF W/ PLAM OVER M GYP. BD. 6„ F 14 TAPERED WALL DETAIL A7.0 SCALE: N.T.S. vocon DESIGN I NC. 2450 Prospect Aven JE Cleveland, Ohio 4411 216 623-6800 p. 216 623-0410 f. vocon@vocon.com n L01515���, 2450 Prospect Ave. 1 st211t$-. 623-68 0 Cleveland, Ohio 44115216-623-0410 a, THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Strsetsboro Rood 330 859-8888 Ph. Richfield, Ohio 44288 330 859-8875 Fox I I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly registered Architect under the laws of the State of which governors this project. WARNING: per LAW No person may alter these documents unless person is, "or under the direct supervision of the licensed architect. Signature: No: S i "+T L A y:,�'� CIO 2004 Type III Branch ConstrucWn Proposed New Carmel, IN d- O C_ O O Q) > Q) a U L_ 0 _O U� O .L_ O Ln O N REVISIONS: A Issued for Bid and Permit 12/30/03 Drawn by: JAC Checked by: MJK Job Number: 3626-000 Dwg• Construction Phase: Documents Sheet Title: Interior Elevations Sheet Number: A=7mO Original Date: December 16, 2003 FULL HEIGHT WALL (SEE SHEET A1.0) COMPUTER EQUIP. BY KEYBANK /=11 r'_%0n1AAACT \A// 01 AC-rin T01KA DIAIr-` AAlr% nn%lCD NOTE: GROMMET LOCATED BELOW COUNTER PLAM FILLER PANEL AS NEEDED PER PHYSICAL FIELD CONDITIONS FOR FINISHED INSTALLATION COORDINATION. PLAM-2 (TYP.) A 1 TELLER COUNTER PLAN r%nTTCr% 1 IAICQ IAIr1lnATC RAI=0t-UAAIMIQIAIr-` On sheet A-2.0 there is a workstation with the designation "WS1 ". The function of this workstation is a "Personal Banker" and would service wheelchair bound customers. TELLER COUNTER FRONT ELEVATION SCALE: 1"=1'-0" PROOF BOX TELLER C SCALE: 1"=1'm0" LAM NTER BACK ELEVATION =lalTl AGE TALLIED -Y W/ KEY REVEAL I CAL IGH FLUSH WOOD EER BASE PHONE EVERY OTHER STATION BY KEY ETO MOUNT UNIT TO WALL. SEE DEIBOLD DWG'S STANDARD PLEXIGLASS MEGALOG HOLDER BY G.C. (MILLWORK VENDOR) UNDERCOUNTER STEEL SU -3-C BY KEY IN MOSLER STANDARD COLOR 251 CORDOVAN FED. STD. 595A (20040) VAT UNIT (SEE DIEBOLD DWG'S) 1'-7" N w MU 4' TELLER COUNTER SECTION SCALE: V=V -0" n 0 3/4" NOTE: CONTR. TO LEAVE MILLWORK FRAMING EXPOSED FOR CABLING DO NOT INSTALL ANY PANELS BELOW TELLER COUNTER AREA. CONTRACTOR TO COORD. W/ KEY BANK CONST. MGR. �— UNDERCOUNTER STEEL SU -3-C BY KEY IN MOSLER STANDARD COLOR 251 CORDOVAN -FED. STD. 595a(20040) (18 3/4" DEEP X 38 1/4" HIGH) TELLER COUNTER AXON N.T.S. All ^r%^R AA Ar --r \A// f11 A f1Tle% Tr'11A A r'%Ik le% A ND COVER )RDINATE FINAL YP TELLER COUNTER AXON N.T.S. PRINTER STAND AXON N.T.S. H PROOF BOX DETAIL A o N.T.S. PLAM3 DEEP WHITE MELAMINE BOX ON (4) SWIVEL CASTERS NOTE: 1 FOR LEXMARK MULTIFUNCTION PRINTER IN SUPPORT AREA �11 X' vocon DESI G N I NC. 2450 Prospect Aven Cleveland, Ohio 4411 216 623-6800 p. 216 623-0410 f. vocon®vocon.com 2450 Prospect Ave. 1s1210–.623 -68i Cleveland, Ohio 44115216-623-0410 THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Rood 330 859-8688 Ph. Richfield, Ohio 44286 330 659-6678 Fax I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly registered Architect under the laws of the State of which governors this project WARNING: per LAW No person may alter these documents unless person is, "or under the direct supervision of the licensed architect. Signature: No: S No Alit+?t�Q!' t' J T A T C 1 4 4 1004 Type III Branch Proposed New Constructt sn Carmel, IN 'iE u7 N O N REVISIONS: /Issued for Bid and Permit 12/30/03 Drawn by: JAC Checked by: MJK Job Number: 3626-000 I Dwg, Construction I Phase: Documents Sheet Title: Teller Station Details Sheet Number: A-8.0 Original Date: December 16, 2003 � GRILLE AND DIFFUSER WASTE SCHEDULE 4' 2" SO -1 SO -2 SO -3 G-1 G-2 MARK 150 FLOOR DRAIN (FD) FROST PROOF HOSE BIBB (FPHB) 3" X 2' 1.5 MANUFACTURER TITUS TINS TENS TRUS TINS MODEL NO. OMNI OMNI OMNI 35ORL 350RL FRAME OR BORDER TYPE LAY -IN SURF MOUNT SURF MOUNT SURF MOUNT LAY -IN MODULE SIZE 24x24 1202 24x24 PER DWG. PER DWG. OPER. WT. (LBS) - REMARKS 1 1 ELECTRICAL (VOLT/PH) 120/1 DAMPER MODEL NUMBER OPER. WE (LBS.) - 32 REMARKS 1 FlNISHITE WHITE WHITE WHITE WHITE 1 1 1 REMARKS REMARKS: 1. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS INDICATED OTHERWISE ON PLAN. PLUMBING FIXTURE CONNECTION SCHEDULE MARK WATER CLOSET (WC) WASTE VENT 4' 2" LAVATORY (L) MOP BASIN (MB) SINK (SK) 1-1/2' EFF4004 3• 1-1 /2' CFM 150 FLOOR DRAIN (FD) FROST PROOF HOSE BIBB (FPHB) 3" X 2' 1.5 ELECTRICAL DATA (VOLT/PH.) DOMESTIC WATER BRANCH PIPE SIZE SCHEDULE 2 TO 4 FLUSH TANK WC, L, S. ENC, DF, BT OR SH-------3�4" HW, CW 5 TO 6 FLUSH TANK WC, L. S, EWC, DF, BT OR SH -------1 HW, CW OVER 6 FLUSH TANK WC, L, S, EWC, DF, BT OR SH -------REFER TO PLAN UNIT HEATER SCHEDULE (ELECTRIC) HW MARK EH -1,2 MANUFACTURER QMARK MODEL NO. EFF4004 TYPE CEILING RECESSED CFM 150 MBH 5.1 KW 1.5 ELECTRICAL DATA (VOLT/PH.) 208/1 REMARKS 1 1 REMARKS: 1. BUILT-IN THERMOSTAT do RECESSED FRAME PACKAGED ROOFTOP AIR CONDITIONING UNIT SCHEDULE HW MARK RTU -1,2 MANUFACTURER CARRIER MODEL NUMBER TFDO06-5 NOMINAL TONNAGE 5.0 SERVICE - SUPPLY AIR CFM 1990 MIN. OUTSIDE AIR CFM 400 EXT. STATIC PRESSURE W.C.) 0.7 MOTOR HP - NAT. GAS HEATING (INPUT) 72 NAT. GAS HEATING (OUTPUT) 59 COOLING TOTAL CAPACITY (MBH) - COOLING SENSIBLE CAPACITY (MBH) - EER - EAT (DB/WB-'F) - FILTER EEF(%) - ELECTRICAL (VOLT/PH) 208/230 3P MCA 29.4 MOCP 35 OPER. WT. (LBS) - REMARKS 1 1 REMARKS: 1. EXISTING UNIT ON ROOF PROVIDED BY LANDLORD, MC TO CONNECT NEW DUCTWORK PER THIS CONTRACT. E 0 N 0 ri E 0 0 0 N C N u 0 b n m 0 N 3 T! O i d �O (D O M O N E 0 Z O, 390 CW HW REWARKS 1 /7' SERVICE W/FLUSH TANK NOMINAL TONNAGE 2.0 TOTAL CAPACITY (MBH) 3/4' 3/4' 18.2 REFRIGERANT R-22 FAN SECTION: . SUPPLY AIR (CFM) W/ TPV-1 3/4' .3 FAN HORSEPOWER 1-5/8' UNISTUT EACH END W/.� (P-4000 C SUCTION OR HOT GAS INSULATED LIQUID ELECTRICAL CONDI UNISTUT PIPE CU NOTES: LIQUID UNE PIPE BE USED AS A INSTALLED 6" LE;.%7111 DUCTLESS SPLIT AIR CONDITIONING UNIT SCHEDULE COOLING COIL SECT. MARK AC -1 SERVICE EM NOMINAL TONNAGE 2.0 TOTAL CAPACITY (MBH) 20.9 SENS CAPACITY (MBH) 18.2 REFRIGERANT R-22 FAN SECTION: IN-LINE SUPPLY AIR (CFM) 800 EXT STAT PRESS AWG) .3 FAN HORSEPOWER 1/3 REHEAT SECTION OUTLET VELOCITY (FPM) CAPACITY (MBH/KW) 24.9/5 TYPE ELECTRIC VOLTAGE 2080d FILTERS DISPOSABLE ELECTRICAL DATA 208/1 MANUFACTURER EMI MODEL NUMBER WSP24 REMARKS 1, 2 1. APPROVED EQUALS ARE CARRIER AND MITSUBISHI. 2. PROVIDE UNIT MOUNTED CONTROLS. FAN SCHEDULE COOLING COIL SECT. MARK EF -1 EF -2 MANUFACTURER COOK COOK MODEL N0. SON -B 70 GC -520 SERVICE TOILET RMS. LOUNGE FAN TYPE IN-LINE CEILING CFM 225 300 TOTAL. STATIC PRESSURE CWC) 0.6 0.375 OUTLET VELOCITY (FPM) 320 943 WHEEL DAA (IN.) NO FANS/HP EACH DRIVEBELT FLA (TOTAL) DIRECT WATTAGE .13 129 MOTOR HP 1/6 .062 FAN RPM 2347 1200 ARRANGEMENT . ELECTRICAL (VOLT/PH) 120/1 120/1 OPER. WE (LBS.) 80 32 REMARKS 1 1, 2 REMARK 1. PROVIDE WITH BACKDRAFT DAMPER do VIBRATION ISOLATED DROP RODS AND DISCONNECT. 2. PROVIDE WITH ALUMINUM CEILING GRILLE. SLOPE AWAY FROM PIPE CHASE SLOPE AWAY FROM PIPING CURB SUPPORT PATE CO. ES STYLE 1A 12 HIGH MIN. 18 GA. WITH 2'x 4' NAILER HUMANE PAI) ON TOP OF ROOFING NOTES: CURB TO BE MAX. 8'-0. O.C. EXISTING METAL CONDENSING UNIT SCHEDULE COOLING COIL SECT. MARK CU -1 SERVICE AC -1 NOMINAL TONNAGE 2.0 CAPACITY (MBH) 24.0 AMBIENT (?F) 95 REFRIGERANT R-22 CONDENSER GPM - COMPRESSOR DATA DRAIN POINT NO/HP EACH 1/- RLA EACH 9.2 STAGES EACH 1 UNIT CAPACITY STEPS % 0-100 CONDENSER DATA NO FANS/HP EACH 1/•12 FLA (TOTAL) - ELECTRICAL DATA 208V-1 PH UNIT MCA 12.4 MANUFACTURER EMI MODEL NUMBER SM24D REMARKS 1, 5 1. APPROVED EQUALS ARE SANYO AND MITSUBISHI. 2. PROVIDE CRANKCASE HEATER, LOW PRESSURE SWITCH AND LOW AMBIENT CONTROL TO 0' . NOTES: ALL SEAMS TO BE SOLDERED WATER TIGHT COOLING COIL SECT. CLEANOUT DRAIN LINE IS ONE SIZE LARGER THAN EQUIPMENT DAN POINT SIZE EQUIPMENT W U Job Number: L DRAIN INVERT _O LL PVC MAIN PIPE f -METAL COVER W/ MIN. 1' INSULATION EQUIPMENT DRAIN POINT SEE NOTE 3 JUNCTION BOXFURNAC TRAP SEAL FASTENED T (SEE NOTES 1 do 2) CLEAN OUT NOTES: 1. FOR DRAINS ON SUCTION SIDE OF FAN USE TMIN. TRAP SEAL OR MAX. FAN SUCTION PRESSURE PLUS 1' WHICHEVER IS GREATER. 2. FOR DRAINS ON DISCHARGE SIDE OF FAN USE TMIN. TRAP SEAL OR MAX. FAN DISCHARGE PRESSURE PLUS 1' WHICHEVER IS GREATER. r. 1ST POINT 3. DISCHARGE OVER FLOOR DRAIN IN FINISHED FLOOR. CONDENSATE DRAIN DETAIL FASTEN COVER AT 12• NTS O.C. THRU CURB CAP. CURB CAP, RIGID INSULATION TO MATCH THICKNESS OF WOOD NAILER. ADHERE TO CURB. > A FABRICATED CURB. 1 1/2' WRAP INSULATION: 18 GA. OVERLAP FOR VNIMUM, STAPLE APOR SEAL NTL. CURBRB SECURE CHASE TO METAL DECK ATJ 1/4 POINTS WITH 2x2x1-1 2 WIDE 16 GAUGE SHEET METAL CUP ANGLES AND FASTEN TO CHASE WITH SCREWS. REFRIGERANT PIPING ROOF CHASE AND PIPE SUPPORT DETAIL NTS NOTES: 1. HVAC CONTRACTOR TO COORDINATE INSTALLATION WITH LANDLORD'S ROOFER FOR PROPER SEQUENCE TO PERMIT FLASHING AND COUNTERFLASHING INSTMUTION. 2. CHASE AND COVER INSTALLATION - 1' THICK NFPA COATED, PINNED ON 4' CENTERS AND GLUED TO SHEET METAL 3. CAULKING TO BE SILICONE BASE AND WATERPROOF. 4. WHERE CHASE HAS NOT BEEN PROVIDED CONTACT LANDLORD FOR REFRIGERANT CHASE LOCATION AND ALTERNATE ENCLOSURE OF PIPING/CONDUIT. �- - - SECURE CURB TO METAL DECK AT 12" O.C. MAX (MIN. 2 PER SIDE) DA. GALV. METAL REFRIGERANT CHASE FOR LOWER TENANTS ONLY. SEE LANDLORD'S DRAWING FOR LOCATION. SECURE INSULATION WITH STICK -PINS AT 18" O.C. AND ADHESIVE ON BOTTOM, FOR DUCTS 24' AND LARGER BELLMOUTH FITTING: WITH DAMPER, EXCEPT IN GYP. BOARD CEILINGS, DAMPER IN NECK TAPE AND MASTIC I OUTER JACKET OWI) MINIMUM RADIUS EQUAL TO THE FLEX DUCT DIAMETER WRAP INSULATION ABOVE THE CEILING DIFFUSERS 24' MAXIMUM VERTICAL DUCT RUN SHUT-OFF VALVE HW SHUT-OFF VALVE TEMPERATURE do PRESSURE CHECK VALVE EXPANSION TANK RELIEF VALVE -� RELIEF LINE PIPE FULL SIZE. TERMINATE AT FLOOR DRAIN WITH f AIR GAP. WATER HEATER D PROVIDE SEISMIC BRACING DRAIN VALVE 2' DEEP GALVANIZED STEEL DRAIN PAN WITH SOLDERED SEAMS. PLYWOOD SHELF 46 1 114* DRAIN LINE TERMINATE AT MOP SINK WITH f AIR GAP. WATER HEATER (SHELF MOUNTED NTS � SUPPORT INDEPENDENTLY OF CW PIPING ��- UNION (TYPICAL) BELLMOUTH FITTING f MIN. 0 a :rff B' 4 y 1.250 DIM ' o CONCENTRIC TEE ECCENTRIC TEE a FITTING a r FITTING IJ SUPPLY DUCT FLAT OVAL DUCT BRANCH TAKE -OFF SIMILAR IJ DUCT BRANCH TAKE -OFF DETAILS NTS HANGER STRAPS: 1'x 22 GAUGE, SUPPORTED FROM STRUCTURE ABOVE, (3) SHEET METAL SCREWS BELOW. ROUND 'SNAPLOCK' SHEET METAL WITH 1 1/2' WRAP INSULATION. ROUND 'SNAPLOCK' (FLEX ONLY IN VERTICAL) BAND CLAMP AND THREE SHEET METAL SCREWS THROUGH HELIX OF FLEXIBLE DUCT LINER (TYPICAL) FLEXIBLE DUCT:SHOULD BE UL 181, CUSS 0 OR CLASS I. INSULATED, ONLY IN VERTICAL CEILING DIFFUSER: SET THROW AS SHOWN ON PLANS vocon DESIGN INC. 2450 Prospect Avenue Cleveland, Ohio 44115 216 623-6800 p. 216 623-0410 f. vocon@vocon.com MA I° T&�C�C���, 2450 Prospect Ave. 1 st fir. 216-623-6800 Cleveland, Ohio 44115 216-623-041 Ofax THORSON BAKER do Associates, Inc. Consulting Engineers 3030 Went Streeteboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax SEAL: JPJA Type III Branch Proposed New Construction Carmel, IN No N I✓ CU Ca) W U Job Number: L _O LL REVISIONS: Issued for Bid and Permit 12/30/03 Drawn by: TBA Checked by: JMZ Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: MECHANICAL SCHEDULES AND DETAILS Sheet Number: M�i so Original December 16, 20( E 0 0 N O E r 0 0 O N O N e m 0 b .1 m 0 U N 0, 3 O N d a) t0 O 1 M O O N 6 E 0 z 0 C-1, 81 75 CFM El 1 F 0 -1 RmH I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ----------------------------� I I FL93 11] ------------!---------------------------- I I I - I El 1 F 0 -1 RmH I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I MECHANICAL PLAN I VENT UP. 4e V.T.R. f VENT UP, 4' V.T.R. MECHANICAL LEGEND 0 POINT OF CONNECTION E) EQUIPMENT TAG CTX CONNECT TO EXISTING M.C. MECHANICAL CONTRACTOR E.C. ELECTRICAL CONTRACTOR P.C. PLUMBING CONTRACTOR G.C. GENERAL CONTRACTOR N.O. NORMALLY OPEN N.C. NORMALLY CLOSED EF EXHAUST FAN CD COLING DIFFUSER RG RETURN GRILLE ER EXHAUST REGISTER SA SUPPLY AIR RA RETURN AIR EA EXHAUST AIR OA OUTSIDE AIR RS REFRIGERANT SUCTION RL REFRIGERANT LIQUID CU CONDENSING UNIT RTU ROOFTOP UNIT ® SUPPLY DUCT RISER zRETURN DUCT RISER ® EXHAUST DUCT RISER Ej SUPPLY DUCT DROP © RETURN DUCT DROP E I EXHAUST DUCT DROP =34UNDERCUT DOOR, REFER TO =t ARCHITECTURAL DRAWINGS QT THERMOSTAT VOLUME DAMPER POINT OF CONNECTION GENERAL NOTES: 1. M.C. TO SIZE REFRIGERANT LINES PER MANUFACTURERS RECOMMENDATIONS AND ROUTE IN CEILING SPACE. 2. REFER TO DRAWING M-1.0 FOR PLUMBING DETAILS, LEGEND, AND SCHEDULES. 3. M.C. TO REBALANCE EXISTING ROOFTOP UNITS FOR AIR QUANTITIES SHOWN ON THIS DRAWING. PLUMBING PLAN 1/'C = 1'-0" PLUMBING LEGEND —SAN — SANITARY SEWER BELOW GRADE -------- V - - - - - - - VENT CD CONDENSATE DRAIN - CW - DOMESTIC COLD WATER — — CW — -- FL93 11] LV0\\O DOMESTIC HOT WATER L MECHANICAL PLAN I VENT UP. 4e V.T.R. f VENT UP, 4' V.T.R. MECHANICAL LEGEND 0 POINT OF CONNECTION E) EQUIPMENT TAG CTX CONNECT TO EXISTING M.C. MECHANICAL CONTRACTOR E.C. ELECTRICAL CONTRACTOR P.C. PLUMBING CONTRACTOR G.C. GENERAL CONTRACTOR N.O. NORMALLY OPEN N.C. NORMALLY CLOSED EF EXHAUST FAN CD COLING DIFFUSER RG RETURN GRILLE ER EXHAUST REGISTER SA SUPPLY AIR RA RETURN AIR EA EXHAUST AIR OA OUTSIDE AIR RS REFRIGERANT SUCTION RL REFRIGERANT LIQUID CU CONDENSING UNIT RTU ROOFTOP UNIT ® SUPPLY DUCT RISER zRETURN DUCT RISER ® EXHAUST DUCT RISER Ej SUPPLY DUCT DROP © RETURN DUCT DROP E I EXHAUST DUCT DROP =34UNDERCUT DOOR, REFER TO =t ARCHITECTURAL DRAWINGS QT THERMOSTAT VOLUME DAMPER POINT OF CONNECTION GENERAL NOTES: 1. M.C. TO SIZE REFRIGERANT LINES PER MANUFACTURERS RECOMMENDATIONS AND ROUTE IN CEILING SPACE. 2. REFER TO DRAWING M-1.0 FOR PLUMBING DETAILS, LEGEND, AND SCHEDULES. 3. M.C. TO REBALANCE EXISTING ROOFTOP UNITS FOR AIR QUANTITIES SHOWN ON THIS DRAWING. PLUMBING PLAN 1/'C = 1'-0" PLUMBING LEGEND —SAN — SANITARY SEWER BELOW GRADE -------- V - - - - - - - VENT CD CONDENSATE DRAIN - CW - DOMESTIC COLD WATER — — CW — -- — COLD WATER UNDER SLAB -- HW -- DOMESTIC HOT WATER G GAS WC WATER CLOSET S SINK LAV LAVATORY CFH CUBIC FEET PER HOUR EWH ELECTRIC WATER HEATER FD FLOOR DRAIN RD ROOF DRAIN OD OVERFLOW DRAIN HB HOSE BIBB CO CLEANOUT V.T.R. VENT THROUGH ROOF INV INVERT ELEVATION TPV TRAP PRIMER VALVE MB MOP BASIN DIRECTION OF FLOW DIRECTION OF DOWNWARD PITCH —��1— PIPE UNION --N— CHECK VALVE SHUTOFF VALVE -+�I-- STRAINER (OH.) T�— STRAINER (PLAN) BACKFLOW PREVENTER PLAN NOTES: O - —1 TO BE SUPPORTED ON WALL ABOVE DOOR. O - AMERICAN WARMING EXHAUST AIR LOUVER. 2802, MODEL LE -52. COLOR TO BE SELECTED BY ARCHITECT. O - DRAIN f CONDENSATE TO HUB DRAIN W/ TR SMITH FIXED AIR GAP MODEL 3950 LOCATED UNDER SINK IN VISIBLE LOCATION FROM CABINET SPACE. O - CONNECT TO EXISTING SANITARY/DOMESTIC WATER PROVIDED BY LANDLORD UNDER BUILDING SHELL PACKAGE O - 10CW do 3/4'HW LINES DOWN FOR CONNECTION TO FIXTURES. vocon DESIGN I NC. 2450 Prospect Avenue Cleveland, Ohio 44115 216 623-6800 p. 216 623-0410 f. vocon@vocon.com K.M. &T@h'NWa9 012@0 2450 Prospect Ave. 1st fir. 216-623-6800 Cleveland, Ohio 44115 216-623-041 Ofax ■-L-� ■■ THORSON BAKER do Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield. Ohio 44286 (330) 659-6675 Fax SEAL: �titi���aC`,soeos•e��f �l/ e • ® P`� C�010r • F4 — L • •', a A .e b� .•L Ff �' • S1H 11+ moi' 4'�. . Type III Branch Proposed New Construction Carmel, IN LID _O ., O C M 0C0 N U L _O LL U)U) O L_ cu C O N N REVISIONS: A Issued for Bid and Permit 12/30/03 Drawn by: TBA Checked by: JMZ Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: MECHANICAL FLOOR PLAN Sheet Number: M�2mO Original December 16, 2003 Date: T 3 0 b II e 0 U 3 v 0 N 1 w 0 0 1 M 0 N m E O Z O� 0 0 F- — — — — —— — — — — — — — — — — — — I I -------------- I — — — — — — — — — — — — — — I I I -----------—---—------- I F---__1 r----il LTJ W / ATM—DETAIL "A» N.T.S. ® POWER CODED NOTES: 1. FURNITURE FEED SHALL CONSIST OF THE FOLLOWING: A FOUR J12 AWG PHASE CONDUCTORS (COLOR: BLACK, RED, BLUE, PINK). B. TWO 10 AWG NEUTRAL CONDUCTORS (COLOR: WHITE W/BLACK STRIPE & WHITE W/RED STRIPE). C. TWO 12 AWG EQUIPMENT GROUNDING CONDUCTORS (COLOR: GREEN FOR NORMAL GROUND do GREEN W/YELLOW STRIPE FOR ISOLATED GROUND). ALL WORK SHALL BE COORDINATED WITH FURNITURE SUPPLIER. THIS E.C. SHALL MAKE ALL FINAL CONNECTIONS TO FURNITURE SYSTEM (INCLUDING CONNECTIONS BETWEEN SEPARATE FURNITURE UNITS.) 2. ONE 1-1/2'' CONDUIT STUBBED FROM JUNCTION BOX INTO ACCESSIBLE CEILING SPACE FOR TELE DATA WIRING. PROVIDE CONDUIT BUSHING AND PULL WIRE VERIFY FINAL CONDUIT SIZE WITH TELE/DATA VENDOR PRIOR TO ROUGH IN. 3. NOT USED. 4. CEILING MOUNTED FLUSH RECEPTACLE (WHITE) FOR FLAT SCREEN VIEWER. VERIFY FINAL LOCATIONS PRIOR TO ROUGH IN. REFER TO ARCHITECTURAL DWGS FOR LOCATION. 5. SEE DETAIL 'A' THIS DWG FOR ADDITIONAL ATM REQUIREMENTS 6. 3/4' C WITH PULL WIRE FOR CONTROL WIRING BETWEEN CU AND AC OR FURNACE 7. E.C. SHALL PROVIDE JUNCTION BOX AND DISCONNECT SWITCH LOCATED ABOVE CEILING FOR MOTORIZED DAMPER BULT INTO HVAC DIFFUSER. E.C. SHALL COORDINATE WITH MECHANICAL CONTRACTOR. 8. 3/4 CONDUIT TO PANEL 'P' FOR INDICATED RECEPTACLE REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 9. 1' CONDUIT WITH PULL WIRE TO ALARM CONTROL CABINET. REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 10. 3/4' CONDUIT WITH PULL WIRE TO AFTER HOURS DEPOSITORY. REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 11. 3/4 LIQUID TIGHT FLEXIBLE METAL CONDUIT TO CABLE CONNECTING PLATE REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 12. CORD AND PLUG PROVIDED WITH ATM UNIT. THIS EC SHALL VERIFY PROPER NEMA CONFIGURATION OF REQUIRED RECEPTACLE REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. POWER PLAN 1/,( = 1'-0' 13. EC SHALL PROVIDE ONE f SQUARE BY 2 1/8' DEEP OUTLET BOX FOR INDICATED QUAD RECEPTACLE AND ONE 4' SQUARE BY 2 1/8' DEEP JUNCTION BOX FOR ATM COMMUNICATION WIRING. QUAD RECEPTACLE SHALL BE LOCATED WITHIN 6'–T OF ATM LOCATION. COMMUNICATION J–BOX SHALL BE LOCATED ADJACENT TO QUAD RECEPTACLE. REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 14. DIAGRAM SHOWN FOR REFERENCE ONLY. THIS EC SWILL COORDINATE, PROVIDE, AND INSTALL ALL REQUIRED EIECTRK:AL RENS (LE CONDUIT, RECEPTACLES, PULL WIRE, BOXES, ETC.) AS REQUIRED BY ATM MANUFACTURER. REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 15. TOILET EXHAUST FAN TO BE CONTROLLED BY TIMECLOCK. 16. RECEPTACLE FOR CCTV SYSTEM HEAD END EQUIPMENT. VERIFY FINAL LOCATION WITH TENANT PRIOR TO ROUGH IN. 17. A.C. POWER WIREMOLD G60DO SERIES, OUTLETS FACE DOWN. MOUNTED AT 7'-6' A.F.F. RECEPTACLES SHALL BE 20 AMP TWIST LOCK (NEMA 15-20R) WITH INSULATED ISOLATED GROUND. SEE DETAIL ON SHEET D1A FOR FURTHER DETAILS AND EQUIPMENT. CONTROL CABLE #20 AV 7 CONDUCTOR IN 3/,f CONTROL CABLE 120 AM 2 CONDUCTOR, TWISTED 3/4' C. vvrun nLVLrIr%#" `III q VACUUM AIR TUBE RISER N.T.S. vocon DESIGN INC. 2450 Prospect Avenue Cleveland, Ohio 44115 216 623-6800 p. 216 623-0410 f. vocon@vocon.com EA Q���o�c�c���, fin& 2450 Prospect Ave. 1 st flr. 216-623-6800 Cleveland, Ohio 44115 216-623-041 Ofax THORSON BAKER do Associates, Inc. Consulting Engineers 3030 West Streeteboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax SEAL: D Ml,, PE19700278 11111 Type III Branch Proposed New Construction Carmel, IN LO O O C co O a� U 0L: _°O LL 4-0 O �L C O LO N O N REVISIONS: A Issued for Bid and Permit 12/30/03 Drawn by: TBA Checked by: JDM Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: POWER PLAN Sheet Number: E�200 Original December 16, 2003 Date: I I I I I I I I I I I I I I I I — — — — — — — — — — — — — — I I I -----------—---—------- I F---__1 r----il LTJ W / ATM—DETAIL "A» N.T.S. ® POWER CODED NOTES: 1. FURNITURE FEED SHALL CONSIST OF THE FOLLOWING: A FOUR J12 AWG PHASE CONDUCTORS (COLOR: BLACK, RED, BLUE, PINK). B. TWO 10 AWG NEUTRAL CONDUCTORS (COLOR: WHITE W/BLACK STRIPE & WHITE W/RED STRIPE). C. TWO 12 AWG EQUIPMENT GROUNDING CONDUCTORS (COLOR: GREEN FOR NORMAL GROUND do GREEN W/YELLOW STRIPE FOR ISOLATED GROUND). ALL WORK SHALL BE COORDINATED WITH FURNITURE SUPPLIER. THIS E.C. SHALL MAKE ALL FINAL CONNECTIONS TO FURNITURE SYSTEM (INCLUDING CONNECTIONS BETWEEN SEPARATE FURNITURE UNITS.) 2. ONE 1-1/2'' CONDUIT STUBBED FROM JUNCTION BOX INTO ACCESSIBLE CEILING SPACE FOR TELE DATA WIRING. PROVIDE CONDUIT BUSHING AND PULL WIRE VERIFY FINAL CONDUIT SIZE WITH TELE/DATA VENDOR PRIOR TO ROUGH IN. 3. NOT USED. 4. CEILING MOUNTED FLUSH RECEPTACLE (WHITE) FOR FLAT SCREEN VIEWER. VERIFY FINAL LOCATIONS PRIOR TO ROUGH IN. REFER TO ARCHITECTURAL DWGS FOR LOCATION. 5. SEE DETAIL 'A' THIS DWG FOR ADDITIONAL ATM REQUIREMENTS 6. 3/4' C WITH PULL WIRE FOR CONTROL WIRING BETWEEN CU AND AC OR FURNACE 7. E.C. SHALL PROVIDE JUNCTION BOX AND DISCONNECT SWITCH LOCATED ABOVE CEILING FOR MOTORIZED DAMPER BULT INTO HVAC DIFFUSER. E.C. SHALL COORDINATE WITH MECHANICAL CONTRACTOR. 8. 3/4 CONDUIT TO PANEL 'P' FOR INDICATED RECEPTACLE REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 9. 1' CONDUIT WITH PULL WIRE TO ALARM CONTROL CABINET. REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 10. 3/4' CONDUIT WITH PULL WIRE TO AFTER HOURS DEPOSITORY. REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 11. 3/4 LIQUID TIGHT FLEXIBLE METAL CONDUIT TO CABLE CONNECTING PLATE REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 12. CORD AND PLUG PROVIDED WITH ATM UNIT. THIS EC SHALL VERIFY PROPER NEMA CONFIGURATION OF REQUIRED RECEPTACLE REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. POWER PLAN 1/,( = 1'-0' 13. EC SHALL PROVIDE ONE f SQUARE BY 2 1/8' DEEP OUTLET BOX FOR INDICATED QUAD RECEPTACLE AND ONE 4' SQUARE BY 2 1/8' DEEP JUNCTION BOX FOR ATM COMMUNICATION WIRING. QUAD RECEPTACLE SHALL BE LOCATED WITHIN 6'–T OF ATM LOCATION. COMMUNICATION J–BOX SHALL BE LOCATED ADJACENT TO QUAD RECEPTACLE. REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 14. DIAGRAM SHOWN FOR REFERENCE ONLY. THIS EC SWILL COORDINATE, PROVIDE, AND INSTALL ALL REQUIRED EIECTRK:AL RENS (LE CONDUIT, RECEPTACLES, PULL WIRE, BOXES, ETC.) AS REQUIRED BY ATM MANUFACTURER. REFER TO 'ATM–DETAIL 'A' ' THIS DRAWING. 15. TOILET EXHAUST FAN TO BE CONTROLLED BY TIMECLOCK. 16. RECEPTACLE FOR CCTV SYSTEM HEAD END EQUIPMENT. VERIFY FINAL LOCATION WITH TENANT PRIOR TO ROUGH IN. 17. A.C. POWER WIREMOLD G60DO SERIES, OUTLETS FACE DOWN. MOUNTED AT 7'-6' A.F.F. RECEPTACLES SHALL BE 20 AMP TWIST LOCK (NEMA 15-20R) WITH INSULATED ISOLATED GROUND. SEE DETAIL ON SHEET D1A FOR FURTHER DETAILS AND EQUIPMENT. CONTROL CABLE #20 AV 7 CONDUCTOR IN 3/,f CONTROL CABLE 120 AM 2 CONDUCTOR, TWISTED 3/4' C. vvrun nLVLrIr%#" `III q VACUUM AIR TUBE RISER N.T.S. vocon DESIGN INC. 2450 Prospect Avenue Cleveland, Ohio 44115 216 623-6800 p. 216 623-0410 f. vocon@vocon.com EA Q���o�c�c���, fin& 2450 Prospect Ave. 1 st flr. 216-623-6800 Cleveland, Ohio 44115 216-623-041 Ofax THORSON BAKER do Associates, Inc. Consulting Engineers 3030 West Streeteboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax SEAL: D Ml,, PE19700278 11111 Type III Branch Proposed New Construction Carmel, IN LO O O C co O a� U 0L: _°O LL 4-0 O �L C O LO N O N REVISIONS: A Issued for Bid and Permit 12/30/03 Drawn by: TBA Checked by: JDM Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: POWER PLAN Sheet Number: E�200 Original December 16, 2003 Date: E 0 0 m E 0 0 0 N C N 0 0 b I n m U fn (V I w co co0 0 I M O O N E 0 z rn 3 r — — F- -- -----------!------ I I I I --------------- I 0 ME 101 ---------------- ------� I ------------------ I I I FIXTURE PROVIDED AND INSTALLED UNDER SHELL CONTW- TYPICALL, CANOPY LIGHTS. oz O rol I I I I O WID AM O& WP KB -20 vocon DESIGN INC. 2450 Prospect Avenue Cleveland, Ohio 44115 216 623-6800 p. 216 623-0410 f. vocon@vocon.com --------------------------------- 2450 Prospect Ave. 1 st fir. 216-623-6800 ® Cleveland, Ohio 44115 216-623-0410fax REFER TO DRIVE-THRU LANE SIGN WIRING DIAGRAM ON THIS SHEET. I FINAL TRACK HEAD ADJUSTMENTS FOR ALL MARKETING SIGNAGE PRIOR TO FINAL COMPLETION. (TYPICAL FOR ALL TRACK HEADS) 7. 3 POSITION SWITCH FOR LANE 1 SIGN. SEE WIRING DIAGRAM THIS SHEET. DRIVE THRU LANE SIGN WIRING DIAGRAM N.T.S. 0 THORSON BAKER do Associates, Inc. Consulting Engineers 3030 West Streeteboro Road (330) 659-6688 Ph. Richfield. Ohio 44286 (330) 659-6675 Fax SEAL: Type III Branch Proposed New Construction Carmel, IN Ail O .L co C O LO N O N REVISIONS: A Issued for Bid and Permit 12/30/03 Drawn by: TBA Checked by: JDM Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: LIGHTING PLAN Sheet Number: Em2ml Original December 16, 2003 r%-4.—. 743 0 EXISTING PANELBOARD DESIGNATION KB 208/120 VOLTS -3- PH. 4 WIRE SOLID NEUTRAL MOUNTING: FLUSH = 400 AMPERE BUS 400- AMPERE MAIN BREAKER SURFACE SPECIAL REQUIREMENTS CKrCKr In 1 KVA 3.6 DESCRIPTION RTU -1 35/3 A B C 4.6 ^ 4.2 ^ 3LIGHTING 4.6 ^ 4.4 ^ 3.6 ^ iil��.• 3.7 ^ /2 2.7 ^ 1 1.3 ^ ^ 2.5 ^ ^ 1.2 ^ ^ 1.2 ^ 2�2 0.75 ^ /2 0.75 ^ • 0.75 ^ 0.75 ^ ^ 0.75 ^ ^ 0.1 1 5� ^ 8.14 ^ 10.26 ^ 8.96 ^ DESCRIPTION KVA AL CANOPY LIGHTS 1.0 2 3 3.6 10.15 - LIGHTING 0.6 4 5 3.6 - 7.92 1.66 1.4 6 7 3.6 RTU -2 UGHTING 1.0 8 9 3.6 0.18 12.69 UGHTING 0.8 10 11 3.6^2 UPS (IG) FAX / COPIER (IG) SPARE - 12 13 2.7 AC -1 ATM SURROUND LTG 1.0 14 15 2.720 REFRIGERATOR 1.0 SPARE - 16 17 1.3 CU -1 SPARE 19 18 19 1.3 + DRIVE THRU SIGNS 1.2 20 21 - SPARE FRONT KEY SIGN 1.2 22 23 - SPARE FRONT LETTER SIGN 1.2 24 25 0.75 EH -2 SPARE - 26 27 0.750.75 0.6 SPARE - 28 29 0.75 EH -1 SPARE 31 30 31 0.75 i SPARE - 32 33 - SPARE NIGHT UGHTING 0.75 34 35 - SPARE 11MECLOCK do CONTACTOR 0.1 36 37 - SPACE PANEL L 8.14 38 3g - SPACE - 40 10.26 40 41 - SPACE 42 KVA SUB TOTALS8.14 10.26 8.96 8.96 42 KVA SUB TOTALS25.04 24.26 20.91 TOTAL CONNECTED LOAD 70.21 KVA 0 C-1 C-1 IBJ ONE LINE DIAGRAM NOTES 1. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER COMPANY REQUIREMENTS PRIOR TO BIDDING AND INCLUDE THE COST OF ALL ASSOCIATED LABOR, MATERIALS, AND CHARGES IN HIS BID. 2. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE FAULT CURRENT WITH THE UTIUTY COMPANY PRIOR TO BIDDING AND PROVIDE EQUIPMENT RATED ACCORDINGLY. SUBMIT FAULT CURRENT CALCULATIONS WITH SHOP DRAWING SUBMITTAL 3. ALL BUSSING SHALL BE COPPER. 4. PROVIDE FULL LENGTH VERTICAL BUSSING IN ALL SWITCHBOARDS, DISTRIBUTION PANELS, AND PANELBOARDS. 5. ALL CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE 6. ALL WALL -MOUNTED EQUIPMENT SHALL BE MOUNTED ON 3/4' FIRE RATED BACKBOARD. 7. PROVIDE NAMEPLATES PER NAMEPLATE DETAIL 8. COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAIN ALL CODE - REQUIRED CLEARANCES. 9. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDmON& REQUIREMENTS. TOTAL 72.75 PANELBOARD DESIGNATION P ELECTRICAL LOAD SCHEDULE KVA ITEM A B C ^ 1.26 ^ ^ 1.44 ^ ^ 1.22 ^ ^ 1.26 ^ ^ 0.9 ^ ^ 0.9 ^ ^ 1.26 ^ ^ 1.18 ^ ^ 2.1 ^ 1.54 ^ ^ 1.08 ^ ^ 1.68 ^ ^ 1.32 ^ ^ 1.6 ^ ^ 1.7 ^ ^ - ^ 2X2 2.56 ^ 1.36 ^ ^ 1.5 r- ^ - ^ DESCRIPTION KVA LOADS (KVAC) 1 LIGHTING RECEPT. HVAC REFRIG. MISC. POWER PANEL KB 0.54 10.15 - 32.6 - 0.1 PANEL P 4 - 7.92 1.66 - 17.78 NEC FACTOR 7 1.25 1.0 1.0 - 1.0 SUB -TOTAL 0.18 12.69 1 7.92 1 34.26 1 17.88 ONE LINE DIAGRAM NOTES 1. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER COMPANY REQUIREMENTS PRIOR TO BIDDING AND INCLUDE THE COST OF ALL ASSOCIATED LABOR, MATERIALS, AND CHARGES IN HIS BID. 2. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE FAULT CURRENT WITH THE UTIUTY COMPANY PRIOR TO BIDDING AND PROVIDE EQUIPMENT RATED ACCORDINGLY. SUBMIT FAULT CURRENT CALCULATIONS WITH SHOP DRAWING SUBMITTAL 3. ALL BUSSING SHALL BE COPPER. 4. PROVIDE FULL LENGTH VERTICAL BUSSING IN ALL SWITCHBOARDS, DISTRIBUTION PANELS, AND PANELBOARDS. 5. ALL CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE 6. ALL WALL -MOUNTED EQUIPMENT SHALL BE MOUNTED ON 3/4' FIRE RATED BACKBOARD. 7. PROVIDE NAMEPLATES PER NAMEPLATE DETAIL 8. COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAIN ALL CODE - REQUIRED CLEARANCES. 9. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDmON& REQUIREMENTS. TOTAL 72.75 PANELBOARD DESIGNATION P 201120 VOLTS _3- PH. -L WIRE SOLID NEUTRAL MOUNTING: FLUSH X 200- AMPERE BUS ZQQ_ AMPERE MAIN LUG SURFACE - SPECK REQUIREMENTS ISOLATED GROUND BAR CKr JIL KVA DESCRIPTION A B C ^ 1.26 ^ ^ 1.44 ^ ^ 1.22 ^ ^ 1.26 ^ ^ 0.9 ^ ^ 0.9 ^ ^ 1.26 ^ ^ 1.18 ^ ^ 2.1 ^ 1.54 ^ ^ 1.08 ^ ^ 1.68 ^ ^ 1.32 ^ ^ 1.6 ^ ^ 1.7 ^ ^ - ^ 2X2 2.56 ^ 1.36 ^ ^ 1.5 r- ^ - ^ DESCRIPTION KVA NL 1 0.72 TELLER RECEPTACLES RECEPTACLES (IG) 0.54 2 3 0.72 TELLER RECEPTACLES RECEPTACLES (IG) 0.72 4 5 0.5 SHREDDER RECEPTACLE SECURITY/CAN (IG) 0.72 6 7 0.54 RECEPTACLES TELCO (IG) 0.72 8 9 0.18 INUGHTEN (IG) RECEPTACLES (IG) 0.72 10 11 0.18 UPS (IG) FAX / COPIER (IG) 0.72 12 13 0.54 EXTERIOR RECPT'S RECEPTACLES (IG) 0.72 14 15 0.18 SREVER (IG) REFRIGERATOR 1.0 16 171 0.9 RECEPTACLES COFFEE 1.2 18 19 0.54 RECEPTACLES FLIT SCREEN VIEWER 1.0 20 21 0.9 RECEPTACLES JANITOR'S CLOSET 0.18 22 23 1.08 RECEPTACLES PARTITION POWER 0.6 24 25 0.72 D7VR/KEY SYSTEM (IG) PARTITION POWER 0.6 26 27 1.0 ATM RECEPTACLE PARTITION POWER 0.6 28 29 0.1 MOTORIZED DAMPER PARTITION IG POWER 1.6 30 31 - SPARE SPARE - 32 33 1.0 EWH-1 EF -1 do EF -2 1.56 34 35 1.0 CCTV RECEPTACLE 0.36 36 37 1.5 DRIVE THRU EQUIPMENT SPARE - 38 39 1.5LANE 1 EQUIPMENT SPARE - 40 41 - SPARE SPARE - 42 KVA SUB TOTALS8.14 10.26 8.96 TOTAL CONNECTED LOAD 27.36 KVA PANELBOARD NOTES 1. ALL BREAKERS SHALL BE 2OA/1P, UNLESS NOTED OTHERWISE 2. Q INDICATES BREAKER SHALL BE 'SMD' RATED. 3. 2© INDICATES BREAKER SHALL BE 'WACR" RATED. 4. 3© INDICATES BREAKER SHALL BE 30 EDA 'G.F.I.' TYPE. 5. ® INDICATES BREAKER SHALL BE SHUNT -TRIP TYPE 6.5© INDICATES BREAKER TO HAVE LACK -ON CUP. 7. ® INDICATES BREAKER TO HAVE LACK -ON CLIP AND RED MARKING. 8. -C-#" INDICATES DESIGNATION OF CONTACTOR CONTROWNG CIRCUIT. SEE CONTACTOR SCHEDULE 9. " i.C:' INDICATES CIRCUIT SHALL BE CONTROLLED BY AUTOMATIC TIME CLOCK DEVICE. 10. 'EX." INDICATES THAT CIRCUIT BREAKER AND WIRING ARE EXISTING. 11. "e SHOWN AS BUSSED SPACE IN THE EVENT THAT THE 125A/3P CIRCUIT BREAKER REQUIRES 6 ACTUAL SPACES. IF CIRCUIT BREAKER ONLY REQUIRES 3 SPACES, EC SHALL PROVIDE 2QA/1P CIRCUIT BREAKERS IN THIS SPACE NAMEPLATE (TYPICAL) SELF TAPPING SCREWS ENGRAVED LAMACOID, 5/32' LETTERS DESIGNATION MM T.C. NAMEPLATES ARE REQUIRED ON ALL PANELBOARDS, STARTERS, DISCONNECT SWITCHES, RELAYS AND JUNCTION BOXES GREATER THAN 4 11/16" SQUARE STANDARD COLORS: 1. NORMAL POWER - BLACK BACKGROUND, WHITE LETTERS 2. IN ADDITION TO THE FUNCTION NAMEPLATE, PROVIDE NAMEPLATES IDENTIFING ALL 'MAIN SERVICE NAMEPLATE DISCONNECTS" - RED BACKGROUND - WHITE LETTERING rEXISTING PANEL 'K0 r------1 - - - - - - - - - - - T 120/208V -30-4W EXISTING LANDLORD WIREWAY 1- - - - - - -1 1---� r -i_- 400 MCL _T------- - I I I I 125A/3P EC SHALL VERIFY THAT METER AND OM CT CABINET ARE EXISTING. IF NOT I PROVIDED UNDER SHELL CONTRACT L_ _ _ _ J EC SHALL PROVIDE IN THIS CONTRACT I PER POWER COMPANY'S SPECIFICATIONS. I TVSS CT'S NOTE 1 I I I I I I I I I LANDLORD'S ELECTRICAL ROOM I I I DOSTTNG (4) #600 KCMIL AND (1) #1/0 GND IN A 4' CDNDUrr. EC SHALL PROVIDE AND INSTALL #6 ISOLATED GROUND FOR PANEL 'Pr. IF ISOLATED GROUND CANNOT BE PULLED THROUGH EXISTING CONDUIT EC SHALL PROVIDE AND INSTALL NEW 3/4' CONDUIT FROM PANEL Ff TO LANDLORD DISTRIBUTION EQUIPMENT WITH 16 ISOLATED GROUND. SM. 1. CURRENT TECHNOLOGY, REMOTE MOUNTED (DIRECTLY UNDER PANEL 'L") TRANSIENT VOLTAGE SURGE SUPPRESSION. MODEL # TG200 (HIGH -TO -MEDIUM EXPOSURE). PROVIDE UNIT WITH INTEGRAL FUSED DISCONNECT SWITCH. PROVIDE DIRECT CONNECTION IN PARALLEL TO THE ELECTRICAL DISTRIBUTION SYSTEM. USE #2 AWG CU FOR PARALLEL PHASE CONDUCTOR CONNECTIONS TO DISCONNECT TERMINALS (AAC). USE #2 AWG CU FOR NEUTRAL (N) AND GROUND (G) CONNECTIONS. REFER TO MANUFACTURER INSTALLATION DIRECTIONS FOR ADDITIONAL INFORMATION. CONDUCTOR LENGTHS MUST BE KEPT TO AN ABSOLUTE MINIMUM. ELECTRICAL ONE -LINE DIAGRAM 120/208V -3--4W N.T.S. NAMEPLATE DETAIL NO SCALE (4) 11/0, (1) 16 GND AND 1 6 ISO. GND IN A 2" CONDUIT. PANEL 'P'' 120/208V-30-0 ISO GND BAR 200 M.LO. EXTERIOR SURFACE MATED I -WWII ML'II VI\VVI\V11\V CONDUCTOR :GTI BUS BAR ISOLATED FROM ENCLOSURE CONNECT ISOLATED GROUND CONDUCTOR TO GROUND SCREW ON ISOLATED GROUND RECEPTACLE CONNECT EQUIPMENT GROUND CONDUCTOR TO GROUND SCREW ON WORK BOX OR BOND TO FURNITURE SYSTEM AS REQUIRED. 1. SIZE ALL GROUNDING ELECTRODE CONDUCTORS, EQUIPMENT GROUNDING CONDUCTORS AND BONDING JUMPERS AS PER NEC ARTICLE 250. 2. ISOLATED GROUND RECEPTACLES SHALL BE INSTALLED PER NATIONAL ELECTRICAL CODE AT LEAST TWO GROUND CONDUCTOR PATHS ARE REQUIRED, ONE FOR THE ISOLATED GROUND RECEPTACLE GROUND SCREW AND THE OTHER FOR THE WORK BOX GROUND SCREW. 3. BOND TO COLD WATER PIPE PER N.E.C. ARTICLE 250. ISOLATED GROUNDING DETAIL N.T.S. vocon DESIGN INC. 2450 Prospect Avenue Cleveland, Ohio 44115 216 623-6800 p. 216 623-0410 f. vocon@vocon.com ■IATA. Q���������� ���❑ 2450 Prospect Ave. 1 st fir. 216-623-6800 Cleveland, Ohio 44115 216-623-041 Ofax ■1_� on THORSON BAKER do Associates, Inc. Consulting Engineers 3030 Weal Streeteboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fox SEAL: D. ........ SE PE1970027/8� i . • TATL Type III Branch Proposed New Construction Carmel, IN L0 V_ • MW CU C> U o REVISIONS: A Issued for Bid and Permit 12/30/03 +? Drawn by: TBA Checked by: JDM Job Number: 3626-000 Dwg. Construction Phase: Documents Sheet Title: ELECTRICAL ONE -LINE DIAGRAM AND DETAILS Sheet Number: E-3.0 Original December 16, 2003