HomeMy WebLinkAbout04741 A-1.04ARCHITECTURAL SYMBOLS
ROOM -ROOM NAME
ROOM -ROOM NAME
201 - ROOM NUMBER
AREA NOT IN CONTRACT
XXXXX INDICATES DOOR NUMBER, SEE SHEET A-5.00 FOR TYPES
& DOOR AND HARDWARE SCHEDULES
O-6.0SIM. -DETAIL NUMBER
-SHEET NUMBER
SEMI -RECESSED FIRE EXTINGUISHER & CABINET. SEE ELEVATION 1/A-6.00 FOR
FURTHER INFORMATION.
PARTITION TYPES
1
PARTITION TYPE
SEE DETAIL 1/A-7.00
Model No.
#1
Location
2
PARTITION TYPE
SEE DETAIL 2/A-7.00
ELKAY
#2
STAINLESS
3
PARTITION TYPE #3
SEE DETAIL 3/A-7.00
CCESSORY SCHEDULE
ARCHITECTURAL NOTES
1. ALL DIMENSIONS ARE FROM FINISH FACE OF PARTITION TO FINISH FACE OF
PARTITION, UNLESS NOTED OTHERWISE.
2. GENERAL CONTRACTOR MUST COORDINATE AMONG ALL TRADES TO ENSURE PROPER
SEQUENCE AND EXECUTION OF WORK.
3. IN THE EVENT OF ANY DISCREPANCIES IN THE DOCUMENTS, OR IF PROBLEMS ARE
ENCOUNTERED DURING CONSTRUCTION, THE GENERAL CONTRACTOR MUST NOTIFY
ARCHITECT BEFORE PROCEEDING WITH THE WORK IN QUESTION.
4. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE GENERAL
CONTRACTOR MUST OBTAIN CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING
WITH CONSTRUCTION.
5. WHERE "MIN." OR "V.I.F." IS INDICATED ON PLANS, GENERAL CONTRACTOR SHALL FIELD
VERIFY THAT THE DIMENSION IS OBTAINABLE. IF NOT, THE GENERAL CONTRACTOR
SHALL BE RESPONSIBLE FOR OBTAINING FURTHER DIRECTION FROM THE ARCHITECT.
6. ALL DRYWALL ABUTTING OTHER MATERIALS SHALL BE FINISHED WITH METAL EDGES.
7. PARTITION TYPES ARE INDICATED ON PLAN, AND IN PARTITION DETAILS. PROVIDE
ADDITIONAL KICK -BRACING TO TYPICAL PARTITION TYPES WHERE WALL -MOUNTED
ELEMENTS OR CLERESTORIES OCCUR ALONG PARTITIONS. GENERAL CONTRACTOR IS
TO COORDINATE, PROVIDE AND INSTALL FOR PARTITIONS KICK -BRACING, DOUBLE
STUDS, FIRE -RETARDANT WOODEN BLOCKING, ETC. AS REQUIRED TO SECURELY
SUPPORT WALL -MOUNTED ELEMENTS. THESE ELEMENTS MAY INCLUDE, BUT ARE NOT
LIMITED TO: FIRE EXTINGUISHER CABINETS.
B. THE HINGE SIDE OF THE DOOR IS TO BE 6" FROM THE INSIDE CORNER OF THE
ROOM INTO WHICH IT LEADS, UNLESS NOTED OTHERWISE.
9. GENERAL CONTRACTOR MUST REPAIR AND RETURN TO A "LIKE -NEW" CONDITION ANY
AND ALL DAMAGE OCCURRING FROM DEMOLITION AND/OR CONSTRUCTION.
10. GENERAL CONTRACTOR TO PROVIDE HOT AND COLD WATER SUPPLY LINES FOR ANY
NEW SINKS SHOWN ON THE ARCHITECTURAL PLAN.
11. GENERAL CONTRACTOR TO MODIFY DEPTH OF PARTITIONS AS REQUIRED TO FULLY
RECESS ELEMENTS CUSTOMARILY RECESSED INTO THE WALL, SUCH AS FIRE
EXTINGUISHER CABINETS, ETC.
12. REFER TO DETAIL 5/A-7.01 FOR COAT CLOSETS, AND DETAIL 6/A-7.01 FOR SUPPLY
ROOM SHELVING, WHERE INDICATED ON THE PLAN. ALL CLOSETS ARE 2'-0" DEEP,
UNLESS DIMENSIONED ON THE PLAN OTHERWISE.
13. G.C. IS TO REVIEW THE SECURITY VENDOR'S SCOPE OF WORK, AND TO COORDINATE
THE SCHEDULING OF SUCH WORK, SO THE G.C. WOULD NOT HAVE ADDITIONAL
DEMOLITION OR PATCHING WORK, AS A RESULT.
14. G.C. TO SUBMIT TO THE ARCHITECT FOR REVIEW ALL PRODUCT SAMPLES,
MANUFACTURER'S DATA AND SHOP DRAWINGS LISTED IN THESE DRAWINGS. THESE
INCLUDE, BUT ARE NOT LIMITED TO, SAMPLES OF ALL FINISHES LISTED IN THE FINISH
SCHEDULE, MANUFACTURER'S DATA ON LIGHT FIXTURES SPECIFIED ON REFLECTED
CEILING PLAN, SHOP DRAWINGS FOR MILLWORK, AND SUBMITTALS FOR ALL DOORS,
FRAMES AND HARDWARE SPECIFIED ON DWG. A-5.00.
15. ALL NEW DOORS SHALL ALLOW 12" MIN. CLEARANCE ON PUSH SIDE OF DOOR AND 18"
MIN. CLEARANCE ON PULL SIDE OF DOORS, UNLESS OTHERWISE NOTED.
16. TO THE EXTENT INDICATED ON THE PLAN, G.C. IS TO PROVIDE 3/4" CDX PLYWOOD
BACKBOARD(S) TO BE PAINTED P-1 IN A FIRE -RETARDANT FORMULA. PLYWOOD
BACKBOARD(S) TO BE 4' X B' SHEET(S), MOUNTED VERTICALLY WITH BOTTOM OF
BOARD(S) MOUNTED AT 24" A.F.F. CLEAR.
17. GENERAL CONTRACTOR IS TO PROVIDE FIRE EXTINGUISHERS AND CABINETS, AS
REQUIRED, IN COMPLIANCE WITH LOCAL CODES TO MATCH EXISTING IN MANUFACTURER,
STYLE AND FINISH. GENERAL CONTRACTOR IS TO COORDINATE FINAL LOCATIONS,
DISTRIBUTION AND QUANTITIES WITH ARCHITECT.
18. ANY ROOMS WHICH ARE PARTIALLY ENCLOSED BY BOTH EXISTING OR BASE BUILDING
PARTITIONS, AND NEW INTERIOR PARTITIONS, G.C. TO TAKE MEASURES TO ENSURE
THAT THE EXISTING OR BASE BUILDING PARTITIONS ARE EQUAL TO OR GREATER THAN
THE NEW INTERIOR PARTITIONS IN FIRE -RATING, VAPOR BARRIER AND/OR SOUND
ATTENUATION.
19. FOR EXTENT OF WATER LINES SERVING COMMERCIAL GRADE APPLIANCES, REFER TO
EQUIPMENT SCHEDULE. FOR LOCATIONS OF SPECIFIC EQUIPMENT WITH WATER LINES,
REFER TO POWER, VOICE AND DATA PLAN.
20. GENERAL CONTRACTOR TO ENSURE THAT EVERY WINDOW OF THE SUITE IS PROVIDED
A COMPLETE SET OF BLDG. STD. WINDOW BLINDS IN GOOD WORKING ORDER WITH
NO MISSING OR BENT VANES. ANY NEW SETS MUST MATCH EXISTING ONES IN
MANUFACTURER, SERIES, DETAILING, ACCESSORIES, FINISH AND OPERATION.
21. GENERAL CONTRACTOR IS TO RESTORE ALL EXISTING DOORS TO BE REUSED TO A
"LIKE -NEW" CONDITION. ANY NEW DOORS TO MATCH EXISTING ONES.
22. GENERAL CONTRACTOR TO FOLLOW BUILDING OWNER'S INSTRUCTIONS FOR THE
LOCATIONS OF, AND THE SCHEDULING FOR CONNECTIONS INTO EXISTING BUILDING
WATER, SOIL AND VENT LINES.
23. ALL PLUMBING LINE PENETRATIONS, AT FLOOR SLABS AND AT FIRE -RATED PARTITIONS,
ARE TO BE THEMSELVES FIRE -RATED IN ACCORDANCE WITH ALL CURRENTLY
APPLICABLE CODES, REGULATIONS AND ORDINANCES OF ALL GOVERNING BODIES HAVING
JURISDICTION OVER THE PROJECT.
Code
Item
Manufacturer
Model No.
Color
Location
Comments
P1
SINK
ELKAY
LRADQ2219
(3 HOLES)
STAINLESS
HIVE #414A & MOTHERS
FIXTURE TO BE ADA COMPLIANT
Al
PAPER TOWEL DISPENSER
BOBRICK
B-2621
STEEL
ROOM #416
SURFACE MOUNTED
P2
FAUCET
SYMMONS
SYMMETRICS
S-23-3
STAINLESS
HIVE #414A & MOTHERS
FIXTURE TO BE ADA COMPLIANT
A2
SOAP DISPENSER
BOBRICK
B-2111
STEEL
ROOM #416
SURFACE MOUNTED
A3
MIRROR
BOBRICK
B-165
STEEL
MOTHERS ROOM #416
WITH STAINLESS STEEL CHANNEL FRAME
NOTES:
1. INSTALL ALL ACCESSORIES PER MANUFACTURER'S INSTRUCTIONS.
2. ALL ACCESSORIES TO BE ADA COMPLIANT.
PLUMBING SCHEDULE
Code
Item
Manufacturer
Model No.
Color
Location
Comments
P1
SINK
ELKAY
LRADQ2219
(3 HOLES)
STAINLESS
STEEL
HIVE #414A
FIXTURE TO BE ADA COMPLIANT
P2
FAUCET
SYMMONS
SYMMETRICS
S-23-3
CHROME
HIVE #414A
FIXTURE TO BE ADA COMPLIANT
Issue For Bid:
STAINLESS
MOTHERS ROOM
P3
SINK
ELKAY
ASANA LLVR1916
STEEL
#416
FIXTURE TO BE ADA COMPLIANT
MOTHERS ROOM
MODIFIED WITH A CHICAGO 0.5 GPM
P4
FAUCET
CHICAGO
895-E35ABCP
CHROME
#416
AERATOR MODEL E2605-5JKCP. FIXTURE
TO BE ADA COMPLIANT
NOTES:
1. INSTALL ALL PLUMBING FIXTURES PER MANUFACTURER'S INSTRUCTIONS.
INICK iv116111er
OF WINDOW
MULLION, TYP.
Architectural Plan
N
SCALE:
1/8" - 1'-0"
H
E
CM/SP
L
L Y
E
R
LEW
Client Approval:
15=
ARCHITECTURE
INTERIOR DESIGN
„"�ve�aahKor9"�rarm�p�,
, r
21 1 South 1 2th St.
Phila., PA 1 9107
21 5.922.7066
THE GENERAL CONTRACTOR IS RESPONSIBLE
TO VERIFY ALL DIMENSIONS ON SITE AND
CONFIRM SUCH DIMENSIONS AGAINST ACTUAL
SITE CONDITIONS. THE GENERAL CONTRACT-
OR SHALL COORDINATE ALL WORK AND
RELATED TRADES, AND SHALL NOTIFY THE
ARCHITECT OF ANY INTERFERENCE OF
MECHANICAL, ELECTRICAL, OR PLUMBING
WORK WITH THE ARCHITECTURAL WORK AND
OF ANY CONFLICTS OR DISCREPANCIES IN
DIMENSIONS AGAINST ON SITE CONDITIONS
PRIOR TO PROCEEDING WITH THE WORK OR
PROCUREMENT OF MATERIALS.
Project:
Liberty
Mutual®
INSURANCE
450 East 96th St
4th Floor
Indianapolis IN 46240
Drawing:
Architectural
Plan
No. A-1.04
Drawn by:
CM/SP
Checked by:
KS
Approved by:
KB_
Client Approval:
Date:
Issue For Bid:
01/26/18
Issue For Permit: 01/29/18
No.
Date
Revision
Scale:
1/8" = 1'-0"
Drawing:
Architectural
Plan
No. A-1.04