Loading...
HomeMy WebLinkAbout04741 A-1.04ARCHITECTURAL SYMBOLS ROOM -ROOM NAME ROOM -ROOM NAME 201 - ROOM NUMBER AREA NOT IN CONTRACT XXXXX INDICATES DOOR NUMBER, SEE SHEET A-5.00 FOR TYPES & DOOR AND HARDWARE SCHEDULES O-6.0SIM. -DETAIL NUMBER -SHEET NUMBER SEMI -RECESSED FIRE EXTINGUISHER & CABINET. SEE ELEVATION 1/A-6.00 FOR FURTHER INFORMATION. PARTITION TYPES 1 PARTITION TYPE SEE DETAIL 1/A-7.00 Model No. #1 Location 2 PARTITION TYPE SEE DETAIL 2/A-7.00 ELKAY #2 STAINLESS 3 PARTITION TYPE #3 SEE DETAIL 3/A-7.00 CCESSORY SCHEDULE ARCHITECTURAL NOTES 1. ALL DIMENSIONS ARE FROM FINISH FACE OF PARTITION TO FINISH FACE OF PARTITION, UNLESS NOTED OTHERWISE. 2. GENERAL CONTRACTOR MUST COORDINATE AMONG ALL TRADES TO ENSURE PROPER SEQUENCE AND EXECUTION OF WORK. 3. IN THE EVENT OF ANY DISCREPANCIES IN THE DOCUMENTS, OR IF PROBLEMS ARE ENCOUNTERED DURING CONSTRUCTION, THE GENERAL CONTRACTOR MUST NOTIFY ARCHITECT BEFORE PROCEEDING WITH THE WORK IN QUESTION. 4. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE GENERAL CONTRACTOR MUST OBTAIN CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING WITH CONSTRUCTION. 5. WHERE "MIN." OR "V.I.F." IS INDICATED ON PLANS, GENERAL CONTRACTOR SHALL FIELD VERIFY THAT THE DIMENSION IS OBTAINABLE. IF NOT, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING FURTHER DIRECTION FROM THE ARCHITECT. 6. ALL DRYWALL ABUTTING OTHER MATERIALS SHALL BE FINISHED WITH METAL EDGES. 7. PARTITION TYPES ARE INDICATED ON PLAN, AND IN PARTITION DETAILS. PROVIDE ADDITIONAL KICK -BRACING TO TYPICAL PARTITION TYPES WHERE WALL -MOUNTED ELEMENTS OR CLERESTORIES OCCUR ALONG PARTITIONS. GENERAL CONTRACTOR IS TO COORDINATE, PROVIDE AND INSTALL FOR PARTITIONS KICK -BRACING, DOUBLE STUDS, FIRE -RETARDANT WOODEN BLOCKING, ETC. AS REQUIRED TO SECURELY SUPPORT WALL -MOUNTED ELEMENTS. THESE ELEMENTS MAY INCLUDE, BUT ARE NOT LIMITED TO: FIRE EXTINGUISHER CABINETS. B. THE HINGE SIDE OF THE DOOR IS TO BE 6" FROM THE INSIDE CORNER OF THE ROOM INTO WHICH IT LEADS, UNLESS NOTED OTHERWISE. 9. GENERAL CONTRACTOR MUST REPAIR AND RETURN TO A "LIKE -NEW" CONDITION ANY AND ALL DAMAGE OCCURRING FROM DEMOLITION AND/OR CONSTRUCTION. 10. GENERAL CONTRACTOR TO PROVIDE HOT AND COLD WATER SUPPLY LINES FOR ANY NEW SINKS SHOWN ON THE ARCHITECTURAL PLAN. 11. GENERAL CONTRACTOR TO MODIFY DEPTH OF PARTITIONS AS REQUIRED TO FULLY RECESS ELEMENTS CUSTOMARILY RECESSED INTO THE WALL, SUCH AS FIRE EXTINGUISHER CABINETS, ETC. 12. REFER TO DETAIL 5/A-7.01 FOR COAT CLOSETS, AND DETAIL 6/A-7.01 FOR SUPPLY ROOM SHELVING, WHERE INDICATED ON THE PLAN. ALL CLOSETS ARE 2'-0" DEEP, UNLESS DIMENSIONED ON THE PLAN OTHERWISE. 13. G.C. IS TO REVIEW THE SECURITY VENDOR'S SCOPE OF WORK, AND TO COORDINATE THE SCHEDULING OF SUCH WORK, SO THE G.C. WOULD NOT HAVE ADDITIONAL DEMOLITION OR PATCHING WORK, AS A RESULT. 14. G.C. TO SUBMIT TO THE ARCHITECT FOR REVIEW ALL PRODUCT SAMPLES, MANUFACTURER'S DATA AND SHOP DRAWINGS LISTED IN THESE DRAWINGS. THESE INCLUDE, BUT ARE NOT LIMITED TO, SAMPLES OF ALL FINISHES LISTED IN THE FINISH SCHEDULE, MANUFACTURER'S DATA ON LIGHT FIXTURES SPECIFIED ON REFLECTED CEILING PLAN, SHOP DRAWINGS FOR MILLWORK, AND SUBMITTALS FOR ALL DOORS, FRAMES AND HARDWARE SPECIFIED ON DWG. A-5.00. 15. ALL NEW DOORS SHALL ALLOW 12" MIN. CLEARANCE ON PUSH SIDE OF DOOR AND 18" MIN. CLEARANCE ON PULL SIDE OF DOORS, UNLESS OTHERWISE NOTED. 16. TO THE EXTENT INDICATED ON THE PLAN, G.C. IS TO PROVIDE 3/4" CDX PLYWOOD BACKBOARD(S) TO BE PAINTED P-1 IN A FIRE -RETARDANT FORMULA. PLYWOOD BACKBOARD(S) TO BE 4' X B' SHEET(S), MOUNTED VERTICALLY WITH BOTTOM OF BOARD(S) MOUNTED AT 24" A.F.F. CLEAR. 17. GENERAL CONTRACTOR IS TO PROVIDE FIRE EXTINGUISHERS AND CABINETS, AS REQUIRED, IN COMPLIANCE WITH LOCAL CODES TO MATCH EXISTING IN MANUFACTURER, STYLE AND FINISH. GENERAL CONTRACTOR IS TO COORDINATE FINAL LOCATIONS, DISTRIBUTION AND QUANTITIES WITH ARCHITECT. 18. ANY ROOMS WHICH ARE PARTIALLY ENCLOSED BY BOTH EXISTING OR BASE BUILDING PARTITIONS, AND NEW INTERIOR PARTITIONS, G.C. TO TAKE MEASURES TO ENSURE THAT THE EXISTING OR BASE BUILDING PARTITIONS ARE EQUAL TO OR GREATER THAN THE NEW INTERIOR PARTITIONS IN FIRE -RATING, VAPOR BARRIER AND/OR SOUND ATTENUATION. 19. FOR EXTENT OF WATER LINES SERVING COMMERCIAL GRADE APPLIANCES, REFER TO EQUIPMENT SCHEDULE. FOR LOCATIONS OF SPECIFIC EQUIPMENT WITH WATER LINES, REFER TO POWER, VOICE AND DATA PLAN. 20. GENERAL CONTRACTOR TO ENSURE THAT EVERY WINDOW OF THE SUITE IS PROVIDED A COMPLETE SET OF BLDG. STD. WINDOW BLINDS IN GOOD WORKING ORDER WITH NO MISSING OR BENT VANES. ANY NEW SETS MUST MATCH EXISTING ONES IN MANUFACTURER, SERIES, DETAILING, ACCESSORIES, FINISH AND OPERATION. 21. GENERAL CONTRACTOR IS TO RESTORE ALL EXISTING DOORS TO BE REUSED TO A "LIKE -NEW" CONDITION. ANY NEW DOORS TO MATCH EXISTING ONES. 22. GENERAL CONTRACTOR TO FOLLOW BUILDING OWNER'S INSTRUCTIONS FOR THE LOCATIONS OF, AND THE SCHEDULING FOR CONNECTIONS INTO EXISTING BUILDING WATER, SOIL AND VENT LINES. 23. ALL PLUMBING LINE PENETRATIONS, AT FLOOR SLABS AND AT FIRE -RATED PARTITIONS, ARE TO BE THEMSELVES FIRE -RATED IN ACCORDANCE WITH ALL CURRENTLY APPLICABLE CODES, REGULATIONS AND ORDINANCES OF ALL GOVERNING BODIES HAVING JURISDICTION OVER THE PROJECT. Code Item Manufacturer Model No. Color Location Comments P1 SINK ELKAY LRADQ2219 (3 HOLES) STAINLESS HIVE #414A & MOTHERS FIXTURE TO BE ADA COMPLIANT Al PAPER TOWEL DISPENSER BOBRICK B-2621 STEEL ROOM #416 SURFACE MOUNTED P2 FAUCET SYMMONS SYMMETRICS S-23-3 STAINLESS HIVE #414A & MOTHERS FIXTURE TO BE ADA COMPLIANT A2 SOAP DISPENSER BOBRICK B-2111 STEEL ROOM #416 SURFACE MOUNTED A3 MIRROR BOBRICK B-165 STEEL MOTHERS ROOM #416 WITH STAINLESS STEEL CHANNEL FRAME NOTES: 1. INSTALL ALL ACCESSORIES PER MANUFACTURER'S INSTRUCTIONS. 2. ALL ACCESSORIES TO BE ADA COMPLIANT. PLUMBING SCHEDULE Code Item Manufacturer Model No. Color Location Comments P1 SINK ELKAY LRADQ2219 (3 HOLES) STAINLESS STEEL HIVE #414A FIXTURE TO BE ADA COMPLIANT P2 FAUCET SYMMONS SYMMETRICS S-23-3 CHROME HIVE #414A FIXTURE TO BE ADA COMPLIANT Issue For Bid: STAINLESS MOTHERS ROOM P3 SINK ELKAY ASANA LLVR1916 STEEL #416 FIXTURE TO BE ADA COMPLIANT MOTHERS ROOM MODIFIED WITH A CHICAGO 0.5 GPM P4 FAUCET CHICAGO 895-E35ABCP CHROME #416 AERATOR MODEL E2605-5JKCP. FIXTURE TO BE ADA COMPLIANT NOTES: 1. INSTALL ALL PLUMBING FIXTURES PER MANUFACTURER'S INSTRUCTIONS. INICK iv116111er OF WINDOW MULLION, TYP. Architectural Plan N SCALE: 1/8" - 1'-0" H E CM/SP L L Y E R LEW Client Approval: 15= ARCHITECTURE INTERIOR DESIGN „"�ve�aahKor9"�rarm�p�, , r 21 1 South 1 2th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual® INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Drawing: Architectural Plan No. A-1.04 Drawn by: CM/SP Checked by: KS Approved by: KB_ Client Approval: Date: Issue For Bid: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Architectural Plan No. A-1.04