Loading...
HomeMy WebLinkAbout04741 A-3.04POWER, VOICE AND DATA SYMBOLS POWER, VOICE AND DATA NOTES Model No. AREA NOT IN CONTRACT 1. UNLESS OTHERWISE NOTED, ALL CONVENIENCE OUTLETS TO BE WHITE IN COLOR. - - 2. UNLESS OTHERWISE NOTED, ALL DEDICATED OUTLETS TO BE GRAY IN COLOR, AND ROOM - ROOM NAME _ BE LABELED. ROOM - ROOM NAME WHIRLPOOL WRS322FDA 401 - ROOM NUMBER 3. UNLESS OTHERWISE NOTED, ALL COVER PLATES TO BE WHITE IN COLOR. ALL EQUIPMENT DESIGNATED BY THIS EQUIPMENT SYMBOL TO RECEIVE E3 (MFD) xx POWER AND RECEPTACLE TYPE AS REQUIRED. REFER TO EQUIPMENT 4. CENTER OF ALL OUTLETS AND CONNECTORS TO BE 1'-6" A.F.F. AND VERTICALLY VENDING MACHINE SCHEDULE FOR MORE INFORMATION - MOUNTED, UNLESS OTHERWISE NOTED. STANDARD DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18" 5, ALL DIMENSIONS SHOWN ARE TO THE CENTER OF THE RECEPTACLE, UNLESS PROVIDED AND INSTALLED BY LIBERTY MUTUAL. G.C. TO PROVIDE A.F.F. UNLESS NOTED OTHERWISE. OTHERWISE NOTED. DEVICES SHOWN CLUSTERED TOGETHER ON THE POWER, DATA WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/ CUT-OFF AP3 AND VOICE PLAN(S) SHALL BE MOUNTED AS CLOSELY TOGETHER AS POSSIBLE. - DEDICATED DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18" A.F.F. VALVE MOUNTED ABOVE THE COUNTERTOP WITH WATTS BRAIDED C UNLESS NOTED OTHERWISE. 6. ALL OUTLETS SHOWN WITH THE SIDE MARK "GFI" ARE TO BE ON A GROUND FAULT INTERRUPTION CIRCUIT. Y 20 AMP DEDICATED DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT MICROWAVE GE PROFILE *20A 18" A.F.F. UNLESS NOTED OTHERWISE. 7. REFER TO THE DEMOLITION PLAN FOR ADDITIONAL INFORMATION RELATED TO POWER ACCUCOLD FF6LB17SSHVADA PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE #3. AND CABLING DEMOLITION. REFRIGERATOR STANDARD GROUND FAULT INTERRUPTER DUPLEX ELECTRICAL OUTLET GFIVERTICALLY ORIENTED AT 42" A.F.F. UNLESS NOTED OTHERWISE. B. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR CONDUIT SHALL BE FULLY PACKED AND SEALED IN ACCORDANCE WITH APPLICABLE BUILDING AND FIRE CODES. STANDARD QUADRAPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18" 9, G.C.'S ELECTRICIAN IS RESPONSIBLE FOR THE HARDWIRED CONNECTION OF FURNITURE A.F.F. UNLESS NOTED OTHERWISE. BASE FEEDS OF TENANT'S SYSTEMS FURNITURE. SYSTEMS FURNITURE ELECTRICAL COMPONENTS TO BE CONNECTED TOGETHER BY THE TENANT'S FURNITURE (3) STUBBED CONDUIT FOR POWER, DATA AND AV. FIRE SAFE AS REQUIRED As N oted INSTALLER, AND VOICE/ DATA CABLING BY TENANT'S VOICE/ DATA CABLING VENDOR.. O❑3D IN ACCORDANCE WITH THESE DRAWINGS. COORDINATE LOCATION WITH FC1 ARCHITECT AND FURNITURE VENDOR PRIOR TO CORING FOR COORDINATION 10. REFER TO DETAIL 2/A-3.04 FOR WIRING DIAGRAMS FOR THE HERMAN MILLER WITH THE TABLE LEG. SEE ENGINEER FOR FURTHER INFORMATION. WORKSTATIONS. ALL RECEPTACLES INSTALLED IN MODULAR FURNITURE SHALL BE PER SYSTEMS FURNITURE WIRING DIAGRAMS. POWER: ONE 1/2" EC STUB. ONE SHIELDED ELECTRICAL CABLE. DATA: ONE 3/4" EC STUB FOR THREE Cat5e NETWORK CABLES TO 11. ALL VOICE AND DATA CABLING TO BE BY THE TENANT'S CABLING VENDOR. G.C. TO THE MDF. COORDINATE CABLING VENDOR'S SCOPE OF WORK WITH HIS OWN. G.C. TO PROVIDE AV: ONE 1-1/4" EC STUB FOR ONE HDMI AND TWO AUDIO TO THE CABLING VENDOR, IN ADVANCE, WITH SCHEDULE SHOWING TIME FRAME FOR CABLING MONITOR ("AV") VENDOR TO RUN CABLES WHEN WALLS AND CEILING ARE OPEN SO THAT CABLING AND INSTALLATION CAN BE ACCOMPLISHED WITHOUT HAVING TO DEMOLISH OR UNDO ANY WORK ALREADY COMPLETED. FLUSH, RECESSED FLOOR OUTLET POKE THRU: O WIREMOLD EVOLUTION 6ATCBK RECESSED POKE THRU ASSEMBLY OR 12. G.C. TO PROVIDE SAFETY GROMMETS, BACK BOXES, CONDUIT WITHIN THE WALLS AND 4D APPROVED EQUAL, W/ (1) 20 AMP DUPLEX RECEPTACLE AND (4) DATA JACKS. PULL LINES FOR VOICE/DATA RECEPTACLES WHERE SHOWN ON G.W.B. PARTITIONS. FB1 G.C. TO PROVIDE ALL DEVICE PLATES AND CONDUIT AS REQUIRED FOR ALL CABLING TO BE DONE BY THE TENANT'S CABLE VENDOR. PROVIDE 3" CONDUIT POWER AND DATA WHICH WILL TERMINATE ABOVE THE CEILING AT THE NEAREST PARTITION BY G.C.'S ELECTRICAL CONTRACTOR. ALL DATA CABLING STUB UP AND TERMINATE 6" ABOVE CEILING, U.N.O., TO BE SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR. 13. ALL POWER, VOICE, DATA AND AV CABLING RUN IN OTHER TENANTS PLENUM SPACE OR CROSSING A COMMON CORRIDOR MUST BE RUN IN CONDUIT. COORDINATE REQUIRED CONDUIT SIZES WITH THE TENANTS CABLING AND AV VENDORS. REFER TO ENGINEERS INDICATES WALL MOUNTED ELECTRICAL RACEWAY MOUNTED AT 18" A.F.F. DRAWINGS FOR FURTHER INFORMATION. UNLESS NOTED OTHERWISE. VOICE/DATA RECEPTACLE (1 VOICE PORT / 1 DATA PORT) AT 18" A.F.F. 14. REFER TO DOOR AND HARDWARE SCHEDULES ON SHEET A-5.00 FOR DOORS WITH UNLESS NOTED OTHERWISE - BACK BOX, SAFETY GROMMET AND PULL CARD READERS, ELECTRICAL LOCK SETS, ETC. 1T/1D STRING BY G.C.'S ELECTRICAL CONTRACTOR, CABLING AND TERMINATION 15. AT RECEPTION DOORS 401A AND 401B THE SECURITY VENDOR IS TO PROVIDE AND DEVICE BY OTHERS. INSTALL WALL MOUNTED SWITCH THAT WILL OPERATE THE DURESS INDICATOR CABLING CONNECTOR (1, 2, 3 OR 4 DATA PORT(S)) AT 18" A.F.F. UNLESS LIGHTS IN OPEN OFFICE #433, #429, #433 AND #435. THE SWITCHES AND LIGHTS SHALL BE PROVIDED AND INSTALLED BY THE SECURITY VENDOR. G.C. TO PROVIDE N NOTED OTHERWISE - BACK BOX, SAFETY GROMMET, PULL STRING, AND J -BOXES AND PULL STRINGS AS REQUIRED. COORDINATE INSTALLATION WITH THE 1D/2D/3D/4D WHEN REQUIRED, CONDUITS, BY G.C.'S ELECTRICAL CONTRACTOR. CABLING SECURITY VENDOR. AND TERMINATION DEVICE BY TENANT'S DATA CABLING VENDOR. 16. G.C. IS TO PROVIDE DOOR BELL AT DOOR #401B, WHICH IS TO SOUND AT WALL INFEED OF POWER ONLY INTO THE BASE OF THE SYSTEMS WORKSTATION IN OPEN AREA #425. FURNITURE ELECTRIFIED BASE. INFEED TO BE MOUNTED IN WALL AT 1 -0 EwF A.F.F. TO CENTERLINE OF INFEED BOX. ELECTRICIAN TO HARDWIRE "POWER 17. G.C. IS TO SUPPLY AND CONNECT WATER LINES TO INTEGRAL ICE MAKERS AND WHIP". IN -DOOR WATER WITHIN REFRIGERATORS, AND COFFEE MAKERS. SEE POWER, VOICE & DATA PLAN FOR LOCATIONS OF EQUIPMENT. WALL INFEED OF VOICE & DATA CABLING INTO THE BASE OF THE SYSTEMS 18. G.C. TO PROVIDE AND INSTALL HARDWIRED TIMING CONTROL DEVICES WITH "NO -HOLD" FURNITURE. INFEED TO BE MOUNTED IN WALL AT 1'-0" A.F.F. TO CENTERLINE OF INFEED BOX. G.C. TO ALSO PROVIDE, A COVER PLATE POSITIONS ONTO ALL OUTLETS TO SERVICE COFFEE MAKERS. TIMING DEVICES MUST WF WITH (2) 1-1/2" DIAMETER GROMMETS. ALL VOICE AND DATA CABLING TO PROVIDE HOURS OF POWER NOT MINUTES. BE SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR, 19. IN TELECOM ROOM #403, FOR THE SECURITY SYSTEM ACCESS CONTROL PANEL: G.C. WHO WILL NEATLY BUNDLE/WRAP THE CABLES GOING THROUGH THE TO PROVIDE (1) DEDICATED 110VAC 20 AMP CIRCUIT. THE TELE/DATA VENDOR IS TO GROMMETS TO THE BASE OF THE SYSTEMS FURNITURE. PROVIDE (1) VOICE DROP AND (1) DATA DROP. LOCATION OF POWER VOICE AND DATA TO BE CONFIRMED WITH THE SECURITY VENDOR PRIOR TO INSTALLATION. ELECTRICAL FLOOR INFEED OF POWER AND VOICE/DATA INTO THE BASE OF THE SYSTEMS FURNITURE ELECTRIFIED BASE. POKE THRU TO BE WIREMOLD 20. IN TELECOM ROOM #403, FOR THE SECURITY ALARM PANEL: G.C. TO PROVIDE (1) EVOLUTION MULTI -SERVICE POKE THRU DEVICE, 6ATCFF OR APPROVED DEDICATED 110VAC 20 AMP CIRCUIT AND THE TELE DATA VENDOR IS TO PROVIDE 1) / EQUAL. CONDUIT AS REQUIRED FOR POWER AND DATA IN PLENUM SPACE FF BELOW BY G.C.'S ELECTRICAL CONTRACTOR, CONFIRM CONDUIT SIZES WITH DEDICATED PHONE LINE. CABLING VENDOR. DIMENSIONS SHOWN ARE TO THE CENTERLINE OF INFEED BOX. INFEED TO BE FLUSH MOUNTED IN SLAB. ELECTRICIAN TO HARDWIRE 21. IN TELECOM ROOM 403, G.C. TO PROVIDE AT A MINIMUM, 1 4" CONDUIT RUN FROM # ( ) "POWER WHIP". ELECTRICAL CONTRACTOR TO MAKE CONNECTION- SEE THE BUILDING DEMARCATION POINT TO THE TELECOM ROOM FOR LIBERTY MUTUAL'S POWER, VOICE & DATA NOTE #9. ALL VOICE AND DATA CABLING TO BE T1 LINE. ALL HOUSE PAIRS, FIBER OPTIC CABLE, AND ANY OTHER CABLE RUNNING SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR, WHO FROM THE BUILDING DEMARCATION POINT TO THE TELECOM ROOM SHALL BE IN WILL NEATLY BUNDLE/WRAP THE CABLES TO THE BASE OF THE SYSTEMS CONDUIT. FURNITURE. SEE ENGINEER'S DRAWINGS FOR FURTHER INFORMATION. 22. G.C. TO PROVIDE CONDUIT FROM TELECOM ROOM #403 TO THE FUTURE TELECOM ROOM BELOW. DIAMETER TO BE DETERMINED BY TENANTS VOICE/DATA VENDOR AND INDICATES THE EXTENT OF THE SYSTEMS FURNITURE ELECTRIFIED BASE BY COORDINATE WITH G.C. CORE DRILLING LOCATION FOR CONDUIT TO BE DETERMINED. FURNITURE VENDOR. G.C. INCLUDE CORE DRILLING IN THE PRICING PHASE. A OR B STANDARD DUPLEX OUTLET (OUTLET "A" OR "B"). NO MORE THAN FOUR OUTLETS "A" OR "B" ON ONE CIRCUIT C OR D STANDARD DUPLEX OUTLET (OUTLET "C' OR "D"). NO MORE THAN EIGHT OUTLETS "C" OR "D" ON ONE CIRCUIT CARD ACCESS PROXIMITY READER FOR TENANT'S SECURITY SYSTEM BY CR SECURITY VENDOR. BACK BOX, SAFETY GROMMET AND PULL STRING BY G.C.'S ELECTRICAL CONTRACTOR. MD MOTION DETECTOR DEVICE FOR TENANT'S SECURITY SYSTEM BY SECURITY VENDOR. USED TO SHUNT THE DOOR CONTACT IN ORDER FOR THE ACCESS CONTROL SYSTEM TO RECOGNIZE THE DOOR IS OPENING BY SOMEONE EXITING AND NOT FORCED OPEN FROM THE OUTSIDE. MOTION DETECTOR DEVICE IS NOT TIED INTO THE DOOR HARDWARE. Dg DOOR BELL. SEE NOTE #16. SINGLE GANG MUD RING WITH TWO PULL STRINGS AT 18" AFF WITH 1-1/4" AV1 CONDUIT TO THE FLOOR STUB BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED FACEPLATES. CHIEF MFG. PAC526 WITH TWO PULL STRINGS WITH 1-1/4" CONDUIT TO FAV -2] THE PLENUM. BOX BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED FACEPLATES. MOUNTING HEIGHT AS INDICATED ON PLANS. t DURESS INDICATOR LIGHT PROVIDED BY TENANT'S SEPARATELY CONTRACTED SECURITY VENDOR. (42) INDICATES DEVICE MOUNTED VERTICALLY AT 42" A.F.F. TO THE CENTER OF THE DEVICE. (VARIES) EX DENOTES ITEM IS EXISTING TO REMAIN ALTERNATES O PROVIDE ADD/ALTERNATE PRICING TO PROVIDE AND INSTALL DATA CABLING PER `LIBERTY MUTUAL INFORMATION TRANSPORT SYSTEMS STANDARDS" DOCUMENT. PER STANDARD DOCUMENT AND ELECTRICAL PLANS, PROVIDE AND INSTALL THE SPECIFIED 4 -POST EQUIPMENT RACK IN TELECOM ROOM. PLEASE CHECK ELECTRICAL PLANS TO DETERMINE IF THIS PROJECT IS VOIP. 3O PROVIDE ADD/ALTERNATE PRICING TO SUPPLY AND INSTALL THE FOLLOWING APPLIANCES: (2) REFRIGERATOR(S), (2) MICROWAVE(S) AND (1) UNDER -COUNTER REFRIGERATOR. REFER TO THE APPLIANCE SCHEDULE FOR SPECIFICATIONS. GENERAL CONTRACTOR PROVIDED EQUIPMENT SHALL BE INVOICED TO LIBERTY MUTUAL SEPARATE FROM THE GENERAL CONTRACT. EQUIPMENT SCHEDULE Code Item Manufacturer Model No. Comments E1 PERSONAL COMPUTER - - PROVIDED AND INSTALLED BY LIBERTY MUTUAL E2 FURNITURE DISPLAY WITH _ _ PROVIDED AND INSTALLED BY LIBERTY MUTUAL AP1 MONITOR WHIRLPOOL WRS322FDA CUT-OFF VALVE MOUNTED AT 18" A.F.F. WITH WATTS BRAIDED STAINLESS C MULTI FUNCTION DEVICE B STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON INLET SIDE. E3 (MFD) - - PROVIDED AND INSTALLED BY LIBERTY MUTUAL APPLIANCE SCHEDULE Code Item Manufacturer Model No. Comments a o a N N ^ a ROOM 420 F PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE #3. G.C. 2Du(36) (36) 21 As 421 TO PROVIDE WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/ AP1 REFRIGERATOR WHIRLPOOL WRS322FDA CUT-OFF VALVE MOUNTED AT 18" A.F.F. WITH WATTS BRAIDED STAINLESS C C I RC;L1 IT B STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON INLET SIDE. B HOT CIRC IL1 I T E1 REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. AP2 VENDING MACHINE - - PROVIDED AND INSTALLED BY LIBERTY MUTUAL No. Date Revision PROVIDED AND INSTALLED BY LIBERTY MUTUAL. G.C. TO PROVIDE WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/ CUT-OFF AP3 COFFEE MAKER - - VALVE MOUNTED ABOVE THE COUNTERTOP WITH WATTS BRAIDED C STAINLESS STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON INLET SIDE. REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. AP4 MICROWAVE GE PROFILE PES7227SLSS PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE #3. AP5 UNDER -COUNTER ACCUCOLD FF6LB17SSHVADA PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE #3. REFRIGERATOR i�icrc ivu�nier EWFICWF EWFICWF EWFICWF FY E FF 428 OPEN OFFICE 430 ■ COAT CLOSET FOCUS ROOM 444 OPEN COLLAB 438 f_EWF CWF E2 i IEWFICWFI ■ 431 IEWFICWFI 432 EWFICWF FFF�� OPEN OFFICE FF a \; CLLA B B O O B 435 4 D /� tEl) E1 E1 E1 E1 � �( � "II EX ID 1D CID 1D ID ID ID ID ID E2 E2 E1 E1 E1 E1 E1 E 2 � EWF CWF A = EWF CWF FF OPEN FF MINNIEx OFFICE OAT 427 � TELECOM M � LOSET QUIET 3 404 _C�ROOM 2D(36) =2D(36)10 403 0 ' UPPL 2D P0100 0 C[ CR 1/00N, ROOM 4 406 1D FOCUS UI FOCUS FOCUS 405 ROOM ROOM ROOM ID ID ID +D O 111 MD ® 408 409 410 ID C CID DID 1DaC O rEl) EI EI & ECEPTION L� CORR. � 446 EX �+ + 401 OO / EX UPOM 0 402 a� OPEN L� SEE 0 COLLAB�a NOTE 1 426 E+ 4D SID EX D EI IC O O o 0 0 0 ID EI FF/ T OO OO OO n No E1 )� FF E OPEN OFFICE 425 FOCUS RO 9M n " O ROOMN P0100 4_3D7 418 417 1 � 03D Ez FC1 -6.0 E OPEN OFFICE 423 E� �� E1 Xl EWFICWF P0100 411 MD EX CR MOTHERS = I ROOM 41-6]MD EWFICWF L E1 CONFERENCE ROOM 412 ' n EI3D -6.0 F � I E2> E1 E1 FF E1 II N N QEATINI;) AREA ° 414B ° ° ° HIVE 414A > 4 ONFERENCE E2 a ROOM ° ao 42) 42) (42) (42) I= O o 415 AP1, N - AP1 N 01 e � 3D FC1 SEE NOTE 7 #18. -6.0 U Aa E1 1D ID E1 EX 4 FICE FF 122 FOCUS ROOM 413 EX N Power Voice & Data Plan SCALE: 1/8"=1-0 THREE (3) 2 POST DATA RACK AND WIRE MANAGERS: FLOOR MOUNTED AND POWERED THROUGHOUT -3.0 3 DED. QUAD 20 AMP. 5-15R DED. L14 -30R 2 POLE 60A INPUT BREAKER HARDWIRE TERMINAL BLOCK 3W+G (L -L -N -G) TO CHASSIS DED. QUAD 20 AMP. 5-15R Enlarged Plan - Telecom Room #403 SECURITY, ALARM AND ACCESS FIVE (5) DED. CONTROL PANELS L6 -20R OUTLETS (STACKED) TO BE HARDWIRED. SEE NOTE #18 & #19. CORR. 447 CM/SP FOCUS a o a N N ^ a ROOM 420 F E3 E3 2Du(36) (36) 21 As 421 UI U C0MMON GIROI.JND C I Iz a LJ I T D H O T C C I RC;L1 IT B C I RcLJ IT B HOT CIRC IL1 I T E1 4 Issue For Bid: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision C D E+ FOCUS RO 9M n " O ROOMN P0100 4_3D7 418 417 1 � 03D Ez FC1 -6.0 E OPEN OFFICE 423 E� �� E1 Xl EWFICWF P0100 411 MD EX CR MOTHERS = I ROOM 41-6]MD EWFICWF L E1 CONFERENCE ROOM 412 ' n EI3D -6.0 F � I E2> E1 E1 FF E1 II N N QEATINI;) AREA ° 414B ° ° ° HIVE 414A > 4 ONFERENCE E2 a ROOM ° ao 42) 42) (42) (42) I= O o 415 AP1, N - AP1 N 01 e � 3D FC1 SEE NOTE 7 #18. -6.0 U Aa E1 1D ID E1 EX 4 FICE FF 122 FOCUS ROOM 413 EX N Power Voice & Data Plan SCALE: 1/8"=1-0 THREE (3) 2 POST DATA RACK AND WIRE MANAGERS: FLOOR MOUNTED AND POWERED THROUGHOUT -3.0 3 DED. QUAD 20 AMP. 5-15R DED. L14 -30R 2 POLE 60A INPUT BREAKER HARDWIRE TERMINAL BLOCK 3W+G (L -L -N -G) TO CHASSIS DED. QUAD 20 AMP. 5-15R Enlarged Plan - Telecom Room #403 SECURITY, ALARM AND ACCESS FIVE (5) DED. CONTROL PANELS L6 -20R OUTLETS (STACKED) TO BE HARDWIRED. SEE NOTE #18 & #19. PBX STATION ry H M H N JU h M IJH WALL FEED _ VOICE STATION y' WALL FEED a b Ci #6 -AWG GROUND BAR. A A /X\ GENERAL PURPOSE + ISOLATED riprUITS SCALE-.o,. CALE: 3 Workstation Wiring Diagram - 8 Wire Harness 1/4" = 1'-0" SCALE: N/A H E L L Y E R LEWIS ARCHITECTURE INTERIOR DESIGN �,Iy.M:'FEw1t JMs dWPCCA 44 w ° ��'iSdi pd Sid lga4S.1'SG4x.. 211 South 1 2th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty • Mutual® INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 HARK ES5 CM/SP Checked by: TO F- 1811LATED NELJTFRAL 0flHNiflN NELJTRAL ISCILATED GFREILIND C0MMON GIROI.JND C I Iz a LJ I T D H O T C I RC;L1 IT C HC]T C I RcLJ IT B HOT CIRC IL1 I T A H O T PBX STATION ry H M H N JU h M IJH WALL FEED _ VOICE STATION y' WALL FEED a b Ci #6 -AWG GROUND BAR. A A /X\ GENERAL PURPOSE + ISOLATED riprUITS SCALE-.o,. CALE: 3 Workstation Wiring Diagram - 8 Wire Harness 1/4" = 1'-0" SCALE: N/A H E L L Y E R LEWIS ARCHITECTURE INTERIOR DESIGN �,Iy.M:'FEw1t JMs dWPCCA 44 w ° ��'iSdi pd Sid lga4S.1'SG4x.. 211 South 1 2th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty • Mutual® INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Drawing: Power, Voice & Data Plan � No. A-3.04 � Drawn by: CM/SP Checked by: KS Approved by: KB_ Client Approval: Date: Issue For Bid: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: As N oted Drawing: Power, Voice & Data Plan � No. A-3.04 �