HomeMy WebLinkAbout04741 A-3.04POWER,
VOICE AND DATA SYMBOLS
POWER, VOICE AND DATA NOTES
Model No.
AREA NOT IN CONTRACT
1.
UNLESS OTHERWISE NOTED, ALL CONVENIENCE OUTLETS TO BE WHITE IN COLOR.
-
-
2.
UNLESS OTHERWISE NOTED, ALL DEDICATED OUTLETS TO BE GRAY IN COLOR, AND
ROOM -
ROOM NAME
_
BE LABELED.
ROOM -
ROOM NAME
WHIRLPOOL
WRS322FDA
401 -
ROOM NUMBER
3.
UNLESS OTHERWISE NOTED, ALL COVER PLATES TO BE WHITE IN COLOR.
ALL EQUIPMENT DESIGNATED BY THIS EQUIPMENT SYMBOL TO RECEIVE
E3
(MFD)
xx
POWER AND RECEPTACLE TYPE AS REQUIRED. REFER TO EQUIPMENT
4.
CENTER OF ALL OUTLETS AND CONNECTORS TO BE 1'-6" A.F.F. AND VERTICALLY
VENDING MACHINE
SCHEDULE FOR MORE INFORMATION
-
MOUNTED, UNLESS OTHERWISE NOTED.
STANDARD DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18"
5,
ALL DIMENSIONS SHOWN ARE TO THE CENTER OF THE RECEPTACLE, UNLESS
PROVIDED AND INSTALLED BY LIBERTY MUTUAL. G.C. TO PROVIDE
A.F.F. UNLESS NOTED OTHERWISE.
OTHERWISE NOTED. DEVICES SHOWN CLUSTERED TOGETHER ON THE POWER, DATA
WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/ CUT-OFF
AP3
AND VOICE PLAN(S) SHALL BE MOUNTED AS CLOSELY TOGETHER AS POSSIBLE.
-
DEDICATED DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18" A.F.F.
VALVE MOUNTED ABOVE THE COUNTERTOP WITH WATTS BRAIDED
C
UNLESS NOTED OTHERWISE.
6.
ALL OUTLETS SHOWN WITH THE SIDE MARK "GFI" ARE TO BE ON A GROUND FAULT
INTERRUPTION CIRCUIT.
Y
20 AMP DEDICATED DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT
MICROWAVE
GE PROFILE
*20A
18" A.F.F. UNLESS NOTED OTHERWISE.
7.
REFER TO THE DEMOLITION PLAN FOR ADDITIONAL INFORMATION RELATED TO POWER
ACCUCOLD
FF6LB17SSHVADA
PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE #3.
AND CABLING DEMOLITION.
REFRIGERATOR
STANDARD GROUND FAULT INTERRUPTER DUPLEX ELECTRICAL OUTLET
GFIVERTICALLY
ORIENTED AT 42" A.F.F. UNLESS NOTED OTHERWISE.
B.
ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR CONDUIT SHALL BE FULLY
PACKED AND SEALED IN ACCORDANCE WITH APPLICABLE BUILDING AND FIRE CODES.
STANDARD QUADRAPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18"
9,
G.C.'S ELECTRICIAN IS RESPONSIBLE FOR THE HARDWIRED CONNECTION OF FURNITURE
A.F.F. UNLESS NOTED OTHERWISE.
BASE FEEDS OF TENANT'S SYSTEMS FURNITURE. SYSTEMS FURNITURE ELECTRICAL
COMPONENTS TO BE CONNECTED TOGETHER BY THE TENANT'S FURNITURE
(3) STUBBED CONDUIT FOR POWER, DATA AND AV. FIRE SAFE AS REQUIRED
As N oted
INSTALLER, AND VOICE/ DATA CABLING BY TENANT'S VOICE/ DATA CABLING VENDOR..
O❑3D
IN ACCORDANCE WITH THESE DRAWINGS. COORDINATE LOCATION WITH
FC1
ARCHITECT AND FURNITURE VENDOR PRIOR TO CORING FOR COORDINATION
10.
REFER TO DETAIL 2/A-3.04 FOR WIRING DIAGRAMS FOR THE HERMAN MILLER
WITH THE TABLE LEG. SEE ENGINEER FOR FURTHER INFORMATION.
WORKSTATIONS. ALL RECEPTACLES INSTALLED IN MODULAR FURNITURE SHALL BE PER
SYSTEMS FURNITURE WIRING DIAGRAMS.
POWER: ONE 1/2" EC STUB. ONE SHIELDED ELECTRICAL CABLE.
DATA: ONE 3/4" EC STUB FOR THREE Cat5e NETWORK CABLES TO
11.
ALL VOICE AND DATA CABLING TO BE BY THE TENANT'S CABLING VENDOR. G.C. TO
THE MDF.
COORDINATE CABLING VENDOR'S SCOPE OF WORK WITH HIS OWN. G.C. TO PROVIDE
AV: ONE 1-1/4" EC STUB FOR ONE HDMI AND TWO AUDIO TO THE
CABLING VENDOR, IN ADVANCE, WITH SCHEDULE SHOWING TIME FRAME FOR CABLING
MONITOR ("AV")
VENDOR TO RUN CABLES WHEN WALLS AND CEILING ARE OPEN SO THAT CABLING
AND INSTALLATION CAN BE ACCOMPLISHED WITHOUT HAVING TO DEMOLISH OR UNDO
ANY WORK ALREADY COMPLETED.
FLUSH, RECESSED FLOOR OUTLET POKE THRU:
O
WIREMOLD EVOLUTION 6ATCBK RECESSED POKE THRU ASSEMBLY OR
12.
G.C. TO PROVIDE SAFETY GROMMETS, BACK BOXES, CONDUIT WITHIN THE WALLS AND
4D
APPROVED EQUAL, W/ (1) 20 AMP DUPLEX RECEPTACLE AND (4) DATA JACKS.
PULL LINES FOR VOICE/DATA RECEPTACLES WHERE SHOWN ON G.W.B. PARTITIONS.
FB1
G.C. TO PROVIDE ALL DEVICE PLATES AND CONDUIT AS REQUIRED FOR
ALL CABLING TO BE DONE BY THE TENANT'S CABLE VENDOR. PROVIDE 3" CONDUIT
POWER AND DATA WHICH WILL TERMINATE ABOVE THE CEILING AT THE
NEAREST PARTITION BY G.C.'S ELECTRICAL CONTRACTOR. ALL DATA CABLING
STUB UP AND TERMINATE 6" ABOVE CEILING, U.N.O.,
TO BE SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR.
13.
ALL POWER, VOICE, DATA AND AV CABLING RUN IN OTHER TENANTS PLENUM SPACE
OR CROSSING A COMMON CORRIDOR MUST BE RUN IN CONDUIT. COORDINATE REQUIRED
CONDUIT SIZES WITH THE TENANTS CABLING AND AV VENDORS. REFER TO ENGINEERS
INDICATES WALL MOUNTED ELECTRICAL RACEWAY MOUNTED AT 18" A.F.F.
DRAWINGS FOR FURTHER INFORMATION.
UNLESS NOTED OTHERWISE.
VOICE/DATA RECEPTACLE (1 VOICE PORT / 1 DATA PORT) AT 18" A.F.F.
14.
REFER TO DOOR AND HARDWARE SCHEDULES ON SHEET A-5.00 FOR DOORS WITH
UNLESS NOTED OTHERWISE - BACK BOX, SAFETY GROMMET AND PULL
CARD READERS, ELECTRICAL LOCK SETS, ETC.
1T/1D
STRING BY G.C.'S ELECTRICAL CONTRACTOR, CABLING AND TERMINATION
15.
AT RECEPTION DOORS 401A AND 401B THE SECURITY VENDOR IS TO PROVIDE AND
DEVICE BY OTHERS.
INSTALL WALL MOUNTED SWITCH THAT WILL OPERATE THE DURESS INDICATOR
CABLING CONNECTOR (1, 2, 3 OR 4 DATA PORT(S)) AT 18" A.F.F. UNLESS
LIGHTS IN OPEN OFFICE #433, #429, #433 AND #435. THE SWITCHES AND LIGHTS
SHALL BE PROVIDED AND INSTALLED BY THE SECURITY VENDOR. G.C. TO PROVIDE
N
NOTED OTHERWISE - BACK BOX, SAFETY GROMMET, PULL STRING, AND
J -BOXES AND PULL STRINGS AS REQUIRED. COORDINATE INSTALLATION WITH THE
1D/2D/3D/4D
WHEN REQUIRED, CONDUITS, BY G.C.'S ELECTRICAL CONTRACTOR. CABLING
SECURITY VENDOR.
AND TERMINATION DEVICE BY TENANT'S DATA CABLING VENDOR.
16.
G.C. IS TO PROVIDE DOOR BELL AT DOOR #401B, WHICH IS TO SOUND AT
WALL INFEED OF POWER ONLY INTO THE BASE OF THE SYSTEMS
WORKSTATION IN OPEN AREA #425.
FURNITURE ELECTRIFIED BASE. INFEED TO BE MOUNTED IN WALL AT 1 -0
EwF
A.F.F. TO CENTERLINE OF INFEED BOX. ELECTRICIAN TO HARDWIRE "POWER
17.
G.C. IS TO SUPPLY AND CONNECT WATER LINES TO INTEGRAL ICE MAKERS AND
WHIP".
IN -DOOR WATER WITHIN REFRIGERATORS, AND COFFEE MAKERS. SEE POWER, VOICE &
DATA PLAN FOR LOCATIONS OF EQUIPMENT.
WALL INFEED OF VOICE & DATA CABLING INTO THE BASE OF THE SYSTEMS
18.
G.C. TO PROVIDE AND INSTALL HARDWIRED TIMING CONTROL DEVICES WITH "NO -HOLD"
FURNITURE. INFEED TO BE MOUNTED IN WALL AT 1'-0" A.F.F. TO
CENTERLINE OF INFEED BOX. G.C. TO ALSO PROVIDE, A COVER PLATE
POSITIONS ONTO ALL OUTLETS TO SERVICE COFFEE MAKERS. TIMING DEVICES MUST
WF
WITH (2) 1-1/2" DIAMETER GROMMETS. ALL VOICE AND DATA CABLING TO
PROVIDE HOURS OF POWER NOT MINUTES.
BE SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR,
19.
IN TELECOM ROOM #403, FOR THE SECURITY SYSTEM ACCESS CONTROL PANEL: G.C.
WHO WILL NEATLY BUNDLE/WRAP THE CABLES GOING THROUGH THE
TO PROVIDE (1) DEDICATED 110VAC 20 AMP CIRCUIT. THE TELE/DATA VENDOR IS TO
GROMMETS TO THE BASE OF THE SYSTEMS FURNITURE.
PROVIDE (1) VOICE DROP AND (1) DATA DROP. LOCATION OF POWER VOICE AND DATA
TO BE CONFIRMED WITH THE SECURITY VENDOR PRIOR TO INSTALLATION.
ELECTRICAL FLOOR INFEED OF POWER AND VOICE/DATA INTO THE BASE OF
THE SYSTEMS FURNITURE ELECTRIFIED BASE. POKE THRU TO BE WIREMOLD
20.
IN TELECOM ROOM #403, FOR THE SECURITY ALARM PANEL: G.C. TO PROVIDE (1)
EVOLUTION MULTI -SERVICE POKE THRU DEVICE, 6ATCFF OR APPROVED
DEDICATED 110VAC 20 AMP CIRCUIT AND THE TELE DATA VENDOR IS TO PROVIDE 1)
/
EQUAL. CONDUIT AS REQUIRED FOR POWER AND DATA IN PLENUM SPACE
FF
BELOW BY G.C.'S ELECTRICAL CONTRACTOR, CONFIRM CONDUIT SIZES WITH
DEDICATED PHONE LINE.
CABLING VENDOR. DIMENSIONS SHOWN ARE TO THE CENTERLINE OF INFEED
BOX. INFEED TO BE FLUSH MOUNTED IN SLAB. ELECTRICIAN TO HARDWIRE
21.
IN TELECOM ROOM 403, G.C. TO PROVIDE AT A MINIMUM, 1 4" CONDUIT RUN FROM
# ( )
"POWER WHIP". ELECTRICAL CONTRACTOR TO MAKE CONNECTION- SEE
THE BUILDING DEMARCATION POINT TO THE TELECOM ROOM FOR LIBERTY MUTUAL'S
POWER, VOICE & DATA NOTE #9. ALL VOICE AND DATA CABLING TO BE
T1 LINE. ALL HOUSE PAIRS, FIBER OPTIC CABLE, AND ANY OTHER CABLE RUNNING
SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR, WHO
FROM THE BUILDING DEMARCATION POINT TO THE TELECOM ROOM SHALL BE IN
WILL NEATLY BUNDLE/WRAP THE CABLES TO THE BASE OF THE SYSTEMS
CONDUIT.
FURNITURE. SEE ENGINEER'S DRAWINGS FOR FURTHER INFORMATION.
22.
G.C. TO PROVIDE CONDUIT FROM TELECOM ROOM #403 TO THE FUTURE TELECOM
ROOM BELOW. DIAMETER TO BE DETERMINED BY TENANTS VOICE/DATA VENDOR AND
INDICATES THE EXTENT OF THE SYSTEMS FURNITURE ELECTRIFIED BASE BY
COORDINATE WITH G.C. CORE DRILLING LOCATION FOR CONDUIT TO BE DETERMINED.
FURNITURE VENDOR.
G.C. INCLUDE CORE DRILLING IN THE PRICING PHASE.
A OR B
STANDARD DUPLEX OUTLET (OUTLET "A" OR "B"). NO MORE THAN FOUR
OUTLETS "A" OR "B" ON ONE CIRCUIT
C OR D
STANDARD DUPLEX OUTLET (OUTLET "C' OR "D"). NO MORE THAN EIGHT
OUTLETS "C" OR "D" ON ONE CIRCUIT
CARD ACCESS PROXIMITY READER FOR TENANT'S SECURITY SYSTEM BY
CR
SECURITY VENDOR. BACK BOX, SAFETY GROMMET AND PULL STRING BY
G.C.'S ELECTRICAL CONTRACTOR.
MD
MOTION DETECTOR DEVICE FOR TENANT'S SECURITY SYSTEM BY SECURITY
VENDOR. USED TO SHUNT THE DOOR CONTACT IN ORDER FOR THE ACCESS
CONTROL SYSTEM TO RECOGNIZE THE DOOR IS OPENING BY SOMEONE
EXITING AND NOT FORCED OPEN FROM THE OUTSIDE. MOTION DETECTOR
DEVICE IS NOT TIED INTO THE DOOR HARDWARE.
Dg
DOOR BELL. SEE NOTE #16.
SINGLE GANG MUD RING WITH TWO PULL STRINGS AT 18" AFF WITH 1-1/4"
AV1
CONDUIT TO THE FLOOR STUB BY G.C.'S ELECTRICAL CONTRACTOR. AV
TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE
REQUIRED FACEPLATES.
CHIEF MFG. PAC526 WITH TWO PULL STRINGS WITH 1-1/4" CONDUIT TO
FAV -2]
THE PLENUM. BOX BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS
BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED
FACEPLATES. MOUNTING HEIGHT AS INDICATED ON PLANS.
t
DURESS INDICATOR LIGHT PROVIDED BY TENANT'S SEPARATELY
CONTRACTED SECURITY VENDOR.
(42)
INDICATES DEVICE MOUNTED VERTICALLY AT 42" A.F.F. TO THE CENTER OF
THE DEVICE. (VARIES)
EX
DENOTES ITEM IS EXISTING TO REMAIN
ALTERNATES
O PROVIDE ADD/ALTERNATE PRICING TO PROVIDE AND INSTALL DATA CABLING PER
`LIBERTY MUTUAL INFORMATION TRANSPORT SYSTEMS STANDARDS" DOCUMENT.
PER STANDARD DOCUMENT AND ELECTRICAL PLANS, PROVIDE AND INSTALL THE
SPECIFIED 4 -POST EQUIPMENT RACK IN TELECOM ROOM. PLEASE CHECK
ELECTRICAL PLANS TO DETERMINE IF THIS PROJECT IS VOIP.
3O PROVIDE ADD/ALTERNATE PRICING TO SUPPLY AND INSTALL THE FOLLOWING
APPLIANCES: (2) REFRIGERATOR(S), (2) MICROWAVE(S) AND (1) UNDER -COUNTER
REFRIGERATOR. REFER TO THE APPLIANCE SCHEDULE FOR SPECIFICATIONS.
GENERAL CONTRACTOR PROVIDED EQUIPMENT SHALL BE INVOICED TO LIBERTY
MUTUAL SEPARATE FROM THE GENERAL CONTRACT.
EQUIPMENT SCHEDULE
Code
Item
Manufacturer
Model No.
Comments
E1
PERSONAL COMPUTER
-
-
PROVIDED AND INSTALLED BY LIBERTY MUTUAL
E2
FURNITURE DISPLAY WITH
_
_
PROVIDED AND INSTALLED BY LIBERTY MUTUAL
AP1
MONITOR
WHIRLPOOL
WRS322FDA
CUT-OFF VALVE MOUNTED AT 18" A.F.F. WITH WATTS BRAIDED STAINLESS
C
MULTI FUNCTION DEVICE
B
STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON INLET SIDE.
E3
(MFD)
-
-
PROVIDED AND INSTALLED BY LIBERTY MUTUAL
APPLIANCE SCHEDULE
Code
Item
Manufacturer
Model No.
Comments
a o a
N N
^
a
ROOM
420
F
PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE #3. G.C.
2Du(36)
(36)
21
As
421
TO PROVIDE WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/
AP1
REFRIGERATOR
WHIRLPOOL
WRS322FDA
CUT-OFF VALVE MOUNTED AT 18" A.F.F. WITH WATTS BRAIDED STAINLESS
C
C I RC;L1 IT
B
STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON INLET SIDE.
B HOT
CIRC IL1 I T
E1
REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION.
AP2
VENDING MACHINE
-
-
PROVIDED AND INSTALLED BY LIBERTY MUTUAL
No.
Date
Revision
PROVIDED AND INSTALLED BY LIBERTY MUTUAL. G.C. TO PROVIDE
WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/ CUT-OFF
AP3
COFFEE MAKER
-
-
VALVE MOUNTED ABOVE THE COUNTERTOP WITH WATTS BRAIDED
C
STAINLESS STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON
INLET SIDE. REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION.
AP4
MICROWAVE
GE PROFILE
PES7227SLSS
PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE #3.
AP5
UNDER -COUNTER
ACCUCOLD
FF6LB17SSHVADA
PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE #3.
REFRIGERATOR
i�icrc ivu�nier
EWFICWF
EWFICWF
EWFICWF
FY
E
FF
428
OPEN
OFFICE
430
■
COAT
CLOSET
FOCUS
ROOM
444
OPEN
COLLAB
438
f_EWF CWF
E2
i
IEWFICWFI
■
431
IEWFICWFI
432
EWFICWF
FFF��
OPEN
OFFICE
FF a \;
CLLA
B B O O B
435
4 D
/�
tEl) E1 E1 E1 E1 � �( � "II
EX ID 1D CID 1D ID
ID ID ID ID
E2 E2
E1 E1 E1 E1 E1 E 2 � EWF CWF A =
EWF CWF
FF OPEN FF
MINNIEx OFFICE OAT
427 �
TELECOM
M � LOSET QUIET
3 404 _C�ROOM 2D(36) =2D(36)10
403 0 ' UPPL 2D P0100
0 C[
CR 1/00N, ROOM 4 406 1D FOCUS UI FOCUS FOCUS
405 ROOM ROOM ROOM
ID ID ID +D O 111 MD ® 408 409 410
ID C CID DID 1DaC O
rEl) EI EI & ECEPTION L� CORR.
� 446
EX �+ + 401
OO / EX
UPOM
0 402 a�
OPEN L� SEE
0 COLLAB�a NOTE
1 426 E+
4D SID
EX
D
EI IC O O o 0 0 0
ID EI
FF/ T OO OO OO n No
E1 )�
FF
E
OPEN
OFFICE
425
FOCUS
RO 9M n " O ROOMN P0100
4_3D7 418 417
1 � 03D
Ez FC1 -6.0
E OPEN
OFFICE
423
E�
��
E1 Xl
EWFICWF
P0100
411 MD
EX
CR
MOTHERS
= I ROOM
41-6]MD
EWFICWF
L E1
CONFERENCE
ROOM
412 ' n
EI3D
-6.0 F � I
E2>
E1
E1
FF
E1
II N N
QEATINI;)
AREA
° 414B
°
°
°
HIVE
414A
>
4 ONFERENCE E2
a ROOM
° ao 42) 42) (42) (42) I= O o 415
AP1, N - AP1 N
01
e � 3D
FC1
SEE NOTE 7
#18.
-6.0
U
Aa
E1 1D ID E1
EX 4
FICE FF
122
FOCUS
ROOM
413
EX
N
Power Voice & Data Plan SCALE:
1/8"=1-0
THREE (3) 2 POST
DATA RACK AND
WIRE MANAGERS:
FLOOR MOUNTED
AND POWERED
THROUGHOUT
-3.0
3
DED. QUAD 20 AMP.
5-15R
DED. L14 -30R
2 POLE 60A INPUT
BREAKER HARDWIRE
TERMINAL BLOCK
3W+G (L -L -N -G) TO
CHASSIS
DED. QUAD 20 AMP.
5-15R
Enlarged Plan - Telecom Room #403
SECURITY, ALARM
AND ACCESS
FIVE (5) DED. CONTROL PANELS
L6 -20R OUTLETS (STACKED) TO BE
HARDWIRED. SEE
NOTE #18 & #19.
CORR.
447
CM/SP
FOCUS
a o a
N N
^
a
ROOM
420
F
E3 E3
2Du(36)
(36)
21
As
421
UI U
C0MMON
GIROI.JND
C I Iz a LJ I T
D H O T
C
C I RC;L1 IT
B
C I RcLJ IT
B HOT
CIRC IL1 I T
E1
4
Issue For Bid:
01/26/18
Issue For Permit: 01/29/18
No.
Date
Revision
C
D
E+
FOCUS
RO 9M n " O ROOMN P0100
4_3D7 418 417
1 � 03D
Ez FC1 -6.0
E OPEN
OFFICE
423
E�
��
E1 Xl
EWFICWF
P0100
411 MD
EX
CR
MOTHERS
= I ROOM
41-6]MD
EWFICWF
L E1
CONFERENCE
ROOM
412 ' n
EI3D
-6.0 F � I
E2>
E1
E1
FF
E1
II N N
QEATINI;)
AREA
° 414B
°
°
°
HIVE
414A
>
4 ONFERENCE E2
a ROOM
° ao 42) 42) (42) (42) I= O o 415
AP1, N - AP1 N
01
e � 3D
FC1
SEE NOTE 7
#18.
-6.0
U
Aa
E1 1D ID E1
EX 4
FICE FF
122
FOCUS
ROOM
413
EX
N
Power Voice & Data Plan SCALE:
1/8"=1-0
THREE (3) 2 POST
DATA RACK AND
WIRE MANAGERS:
FLOOR MOUNTED
AND POWERED
THROUGHOUT
-3.0
3
DED. QUAD 20 AMP.
5-15R
DED. L14 -30R
2 POLE 60A INPUT
BREAKER HARDWIRE
TERMINAL BLOCK
3W+G (L -L -N -G) TO
CHASSIS
DED. QUAD 20 AMP.
5-15R
Enlarged Plan - Telecom Room #403
SECURITY, ALARM
AND ACCESS
FIVE (5) DED. CONTROL PANELS
L6 -20R OUTLETS (STACKED) TO BE
HARDWIRED. SEE
NOTE #18 & #19.
PBX STATION ry H M H N JU h M IJH
WALL FEED
_ VOICE STATION y'
WALL FEED a b Ci
#6 -AWG
GROUND BAR. A A
/X\
GENERAL PURPOSE + ISOLATED riprUITS
SCALE-.o,.
CALE: 3 Workstation Wiring Diagram - 8 Wire Harness
1/4" = 1'-0"
SCALE:
N/A
H E L L Y E R
LEWIS
ARCHITECTURE
INTERIOR DESIGN
�,Iy.M:'FEw1t JMs dWPCCA
44
w °
��'iSdi pd Sid lga4S.1'SG4x..
211 South 1 2th St.
Phila., PA 1 9107
21 5.922.7066
THE GENERAL CONTRACTOR IS RESPONSIBLE
TO VERIFY ALL DIMENSIONS ON SITE AND
CONFIRM SUCH DIMENSIONS AGAINST ACTUAL
SITE CONDITIONS. THE GENERAL CONTRACT-
OR SHALL COORDINATE ALL WORK AND
RELATED TRADES, AND SHALL NOTIFY THE
ARCHITECT OF ANY INTERFERENCE OF
MECHANICAL, ELECTRICAL, OR PLUMBING
WORK WITH THE ARCHITECTURAL WORK AND
OF ANY CONFLICTS OR DISCREPANCIES IN
DIMENSIONS AGAINST ON SITE CONDITIONS
PRIOR TO PROCEEDING WITH THE WORK OR
PROCUREMENT OF MATERIALS.
Project:
Liberty
•
Mutual®
INSURANCE
450 East 96th St
4th Floor
Indianapolis IN 46240
HARK ES5
CM/SP
Checked by:
TO F-
1811LATED
NELJTFRAL
0flHNiflN
NELJTRAL
ISCILATED
GFREILIND
C0MMON
GIROI.JND
C I Iz a LJ I T
D H O T
C I RC;L1 IT
C HC]T
C I RcLJ IT
B HOT
CIRC IL1 I T
A H O T
PBX STATION ry H M H N JU h M IJH
WALL FEED
_ VOICE STATION y'
WALL FEED a b Ci
#6 -AWG
GROUND BAR. A A
/X\
GENERAL PURPOSE + ISOLATED riprUITS
SCALE-.o,.
CALE: 3 Workstation Wiring Diagram - 8 Wire Harness
1/4" = 1'-0"
SCALE:
N/A
H E L L Y E R
LEWIS
ARCHITECTURE
INTERIOR DESIGN
�,Iy.M:'FEw1t JMs dWPCCA
44
w °
��'iSdi pd Sid lga4S.1'SG4x..
211 South 1 2th St.
Phila., PA 1 9107
21 5.922.7066
THE GENERAL CONTRACTOR IS RESPONSIBLE
TO VERIFY ALL DIMENSIONS ON SITE AND
CONFIRM SUCH DIMENSIONS AGAINST ACTUAL
SITE CONDITIONS. THE GENERAL CONTRACT-
OR SHALL COORDINATE ALL WORK AND
RELATED TRADES, AND SHALL NOTIFY THE
ARCHITECT OF ANY INTERFERENCE OF
MECHANICAL, ELECTRICAL, OR PLUMBING
WORK WITH THE ARCHITECTURAL WORK AND
OF ANY CONFLICTS OR DISCREPANCIES IN
DIMENSIONS AGAINST ON SITE CONDITIONS
PRIOR TO PROCEEDING WITH THE WORK OR
PROCUREMENT OF MATERIALS.
Project:
Liberty
•
Mutual®
INSURANCE
450 East 96th St
4th Floor
Indianapolis IN 46240
Drawing:
Power, Voice
& Data Plan
� No. A-3.04 �
Drawn by:
CM/SP
Checked by:
KS
Approved by:
KB_
Client Approval:
Date:
Issue For Bid:
01/26/18
Issue For Permit: 01/29/18
No.
Date
Revision
Scale:
As N oted
Drawing:
Power, Voice
& Data Plan
� No. A-3.04 �