HomeMy WebLinkAbout04741 A-5.00HARDWARE SCHEDULE SET #1 - CLOSET PASSAGE LATCHSET (SINGLE DOOR) SET #7 - ELECTRIC STRIKE WITH CLOSER 2 PAIR HINGES 1 LATCHSET 1 OVERHEAD STOP 4 RUBBER SILENCERS 4 1/2" ANTI -FRICTION BEARING HINGES FINISH: MATCH EXISTING BLDG. STD. PASSAGE LEVER LATCHSET FINISH: MATCH EXISTING "RIXSON" #10 SERIES OVERHEAD STOP FINISH: MATCH EXISTING SET #2 - PASSAGE LATCHSET 2 PAIR HINGES 1 LATCHSET 4 RUBBER SILENCERS 4 1/2" ANTI -FRICTION BEARING HINGES FINISH: MATCH EXISTING BLDG. STD. LEVER PASSAGE LATCHSET FINISH: MATCH EXISTING SET #3 - CLASSROOM LOCKSET (SINGLE) 2 PAIR HINGES 1 LOCKSET 1 FLOOR STOP 4 RUBBER SILENCERS 4 1/2" ANTI -FRICTION BEARING HINGES FINISH: MATCH EXISTING BLDG. STD. LEVER CLASSROOM LOCKSET FINISH: MATCH EXISTING "RIXSON" #10 SERIES FLOOR STOP FINISH: MATCH EXISTING SET #4 - STOREROOM LOCKSET WITH CLOSER 2 PAIR HINGES 4 1/2" ANTI -FRICTION BEARING HINGES FINISH: MATCH EXISTING FINISH: MATCH EXISTING 1 LOCKSET BLDG. STD. LEVER STOREROOM LOCKSET SERIES (PULL SIDE MOUNTED) WITH 72MC FINISH: MATCH EXISTING 1 CLOSER W/HOLD ADA COMPLIANT "LCN CLOSERS" OR EQUAL: 4040XP OPEN SERIES SMOOTHIE (PULL -SIDE OR PULL MOUNTED) HES, SERIES 1006CS , .25 AMPS @ 24VDC FINISH: POWDER COAT FINISH: MATCH EXISTING 1 FLOOR STOP "IVES" #436 FINISH: MATCH EXISTING FINISH: MATCH EXISTING 4 RUBBER SILENCERS SET #5 - CLOSET DUMMY TRIM (PAIR OF DOORS) 4 PAIR HINGES 4 1/2" ANTI -FRICTION BEARING HINGES SUPPLY AS REQUIRED. COORDINATE WITH FINISH: MATCH EXISTING 2 DUMMY TRIM BLDG. STD. LEVER DUMMY TRIM FINISH: MATCH EXISTING 2 MAGNETIC CATCHES 2 OVERHEAD STOPS "RIXSON" #10 SERIES OVERHEAD STOP FINISH: MATCH EXISTING 4 RUBBER SILENCERS SET #6 - ENTRANCE LOCKSET WITH CLOSER 2 PAIR HINGES 1 LOCKSET 1 CLOSER 1 FLOOR STOP 4 RUBBER SILENCERS DOOR TYPES SCALE: 3/8" = 1'-0" 4 1/2" ANTI -FRICTION BEARING HINGES FINISH: MATCH EXISTING BLDG. STD. LEVER ENTRANCE LOCKSET FINISH: MATCH EXISTING ADA COMPLIANT "LCN CLOSERS" OR EQUAL: 4040XP SERIES (PULL -SIDE MOUNTED) FINISH: POWDER COAT TO MATCH EXISTING "IVES" #438 FINISH: MATCH EXISTING BY GENERAL CONTRACTOR: 2 PAIR HINGES 1 CLOSER 1 ELEC. STRIKE 1 LOCKSET 1 POWER SUPPLY 1 FLOOR STOP 4 1/2" ANTI -FRICTION BEARING HINGES RELEASES IFR �mW3TRlllCTI�N FINISH: MATCH EXISTING 2 HINGES "ADA COMPLIANT LCN CLOSERS" OR EQUAL: 4040XP SERIES (PULL SIDE MOUNTED) WITH 72MC METAL COVER IC'Itp� o�F Cairrnrel FINISH: MATCH EXISTING Dr�TEa 02/23/18 HES, SERIES 1006CS , .25 AMPS @ 24VDC WITH HES SMART PAC III ON FAIL SAFE HARDWARE 1 ELEC. STRIKE FINISH: MATCH EXISTING BLDG. STD. STOREROOM LEVER LOCKSET FINISH: MATCH EXISTING 1 LOCKSET GC TO PROVIDE ALL POWER TO STRIKE POWER SUPPLY AS REQUIRED. COORDINATE WITH SECURITY VENDOR Thk. "IVES" #438 1 POWER SUPPLY FINISH: MATCH EXISTING Mat. 4 RUBBER SILENCERS BY TENANT'S SECURITY VENDOR 1 CARD READER 1 MOTION DETECTOR DEVICE INSTALLATION TO BE COORDINATED WITH THE LANDLORD. PROVIDE 24V DC POWER. CORRIDOR TRIM IS ELECTRICALLY UNLOCKED BY CARD READER OR KEY OVERRIDE. INTERIOR TRIM IS ALWAYS FREE FOR IMMEDIATE EGRESS. TELECOM ROOMS TO BE FAIL-SAFE. ALL OTHER ROOMS TO BE FAIL-SAFE. AS REQUIRED, ACCESS CONTROLLED DOORS WILL BE TIED TO THE LIFE SAFETY SYSTEM REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. ALL ACCESS CONTROLLED DOORS WILL MEET THE REQUIREMENTS OF INDIANA STATE CODE. G.C. TO COORDINATE "J" BOX LOCATION FOR THE CARD READERS WITH TENANT'S SECURITY VENDOR. SET #e - ELECTRIC STRIKE WITH CLOSER (MOTHER'S ROOM) BY GENERAL CONTRACTOR: RELEASES IFR �mW3TRlllCTI�N Frame 2 HINGES 4 1/2" ANTI -FRICTION BEARING HINGES 5uuh�j�o�ktio a"mipdiian�c®wlNo ®III r�gwf�timns FINISH: SATIN CHROME 1 CLOSER "ADA COMPLIANT LCN CLOSERS" OR EQUAL: 4040XP IC'Itp� o�F Cairrnrel SERIES (PUSH SIDE MOUNTED) WITH 72MC Dr�TEa 02/23/18 METAL COVER Nick Mishler FINISH: SATIN CHROME 1 ELEC. STRIKE HES, SERIES 1006CS , .25 AMPS @ 24VDC WITH HES SMART PAC III ON FAIL SAFE HARDWARE FINISH: SATIN CHROME 1 LOCKSET SCHLAGE L SERIES MORTISE OR APPROVED EQUAL Label VACANT/OCCUPIED THUMBTURN INDICATOR W/ Width ESCUTCHEON TRIM Thk. FINISH: SATIN CHROME 1 POWER SUPPLY GC TO PROVIDE ALL POWER TO STRIKE POWER Mat. SUPPLY AS REQUIRED. COORDINATE WITH SECURITY No. VENDOR 1 FLOOR STOP "IVES" #438 FINISH: SATIN CHROME 4 RUBBER SILENCERS BY TENANT'S SECURITY VENDOR: 1 CARD READER 1 MOTION DETECTOR DEVICE INSTALLATION TO BE COORDINATED WITH THE LANDLORD. PROVIDE 24V DC POWER. CORRIDOR TRIM IS ELECTRICALLY UNLOCKED BY CARD READER OR KEY OVERRIDE. INTERIOR TRIM IS ALWAYS FREE FOR IMMEDIATE EGRESS. AS REQUIRED, ACCESS CONTROLLED DOORS WILL BE TIED TO THE LIFE SAFETY SYSTEM REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. ALL ACCESS CONTROLLED DOORS WILL MEET THE REQUIREMENTS OF INDIANA STATE CODE. G.C. TO COORDINATE "J" BOX LOCATION FOR THE CARD READERS WITH TENANT'S SECURITY VENDOR. DOOR SCHEDULE First Floor RELEASES IFR �mW3TRlllCTI�N Frame L Y E R ��;�,���� ,. � 5uuh�j�o�ktio a"mipdiian�c®wlNo ®III r�gwf�timns W rn95tal� emd Ilmeal Or'"dle�� Remarks IC'Itp� o�F Cairrnrel "��� Dr�TEa 02/23/18 Date: Nick Mishler DOOR SCHEDULE First Floor Door Frame L Y E R L E W Hardware Set Remarks Client Approval: Date: Door No. Room No. Label Type Width Height Thk. Mat. Finish Type Mat. Finish No. 401A 401 - A SINGLE MATCH 1-3/4" SC. WD. ST -1 2 H.M. P2 6 3,_0" EX. 401B 401 - D SINGLE MATCH" 1-3/4 SC. WD./ ST -1 1 H.M. P2 7 31-0" EX. TEMP. GL 401C 401 - D SINGLE MATCH" 1-3/4 SC. WD./ ST -1 1 H.M. P2 7 31-0" EX. TEMP. GL 402 402 - A SINGLE MATCH 1-3/4" SC. WD. ST -1 1 H.M. P2 4 31_0" ET. 403 403 - A SINGLE MATCH 1-3/4" SC. WD. ST -1 1 H.M. P2 7 31_0" ET. 404 404 - A SINGLE MATCH 1-3/4" SC. WD. ST -1 1 H.M. P2 1 31-0" EX. 405 405 - A SINGLE MATCH 1-3/4" SC. WD. ST -1 1 H.M. P2 4 3,-0 EX 407 407 - A SINGLE MATCH 1_3/4" SC. WD. ST -1 1 H.M. P2 2 310.EX. 415 415 - A SINGLE MATCH 1-3/4" SC .WD. ST -1 2 H.M. P2 2 3,_0" EX. 416 416 - A SINGLE MATCH 1-3/4" SC. WD. ST -1 1 H.M. P2 8 31-0" EX. 424 424 - C DOUBLE (2)3'-0" MATCH EX. 1-3/4" SC. WD. ST -1 3 H.M. P2 5 ADJUST EXISTING HARDWARE 428 428 - A EX. EX. EX. EX. EX. EX. EX. P2 7 AS NECESSARYTO CONFORM TO HARDWARE SET #7. 432 432 - A SINGLE MATCH 1-3/4" SC .WD. ST -1 2 H.M. P2 3 3.-0" EX. 436 436 - B SINGLE MATCH" 1-3/4 SC. WD./ ST -1 1 H.M. P2 7 31-0" EX. TEMP. GL. 441 441 - C ()3BoE M ATETCH 1-3/4" SC .WD. ST -1 3 H.M. P2 5 443 443 - A SINGLE MATCH 1-3/4" SC .WD. ST -1 2 H.M. P2 2 31-0" EX. 445 445 - A SINGLE MATCH 1-3/4" SC .WD. ST -1 2 H.M. P2 2 31-0" EX. DOOR AND HARDWARE NOTES 1. G.C. TO PROVIDE CUT -SHEETS OF ALL HARDWARE PROPOSED, FOR ARCHITECT'S REVIEW, PRIOR TO ORDERING. 2. G.C. TO COORDINATE HARDWARE PURCHASE, SPECIFICATION AND INSTALLATION WITH BUILDING MANAGEMENT. 3. FURNISH 2 PAIR HINGES PER LEAF, UNLESS OTHERWISE NOTED. FURNISH HINGES WITH STAINLESS STEEL PINS AND CONCEALED BEARINGS. SIZE LISTED IN HARDWARE SETS INDICATES HEIGHT. 4. FURNISH SILENCERS FOR ALL INTERIOR FRAMES; 3 FOR SINGLE DOORS, 4 FOR PAIR OF DOORS. OMIT WHERE SOUND OR LIGHT SEAL OCCURS. 5. ALL LEVER SETS TO BE 3'-3" FROM THE BOTTOM OF THE DOOR TO THE CENTER OF THE LEVER. 6. INSTALL EACH HARDWARE ITEM PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. DO NOT INSTALL SURFACE MOUNTED ITEMS UNTIL FINISHES HAVE BEEN COMPLETED ON THE SUBSTRATE. SET UNITS LEVEL, PLUM AND TRUE TO LINE AND LOCATION. 7. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY. 8. KEYING OF CYLINDER LOCKS SHALL BE COORDINATED WITH THE OWNER, FOR ESTIMATE USE GRANDMASTER KEYING CHARGE. UNDER OWNER'S DIRECTION, KEY TO NEW OR EXISTING SYSTEM TO BE APPROVED BY OWNER'S REPRESENTATIVE IN WRITING. FURNISH CONSTRUCTION KEY SYSTEM WITH KEYS THAT CAN BE RENDERED INOPERATIVE BY THE TURN OF A CHANGE KEY. STAMP ALL KEYS "DO NOT DUPLICATE". FOR PROTECTION OF THE OWNER, ALL LOCKS AND CYLINDERS SHALL BE KEYED AT THE FACTORY OF THE LOCK MANUFACTURER WHERE PERMANENT RECORDS ARE MAINTAINED. 9. LIBERTY MUTUAL SHALL RECEIVE THREE KEYS FOR EACH LOCK AND SIX MASTER KEYS FOR EACH SET. REVIEW WITH LANDLORD OR BUILDING MANAGER IF THEY REQUIRE A BUILDING APPROVED LOCKSMITH FOR ALL KEY AND LOCK WORK. 10. ALL EXIT DOORS SCHEDULED WITH ELECTRONIC HARDWARE SHALL UNLOCK UPON THE ACTUATION OF A LIFE SAFETY DEVICE. ALL DOORS REQUIRED AS EXITS WITH ELECTRONIC HARDWARE UNLOCK UPON THE LOSS OF POWER CONTROLLING THE LOCK OR LOCK MECHANISM. ALL DOORS REQUIRED AS EXITS WITH ELECTRONIC HARDWARE SHALL HAVE THE CAPABILITY OF BEING UNLOCKED BY A SIGNAL FROM THE FIRE COMMAND CENTER IN HIGH RISE BUILDING WHERE APPLICABLE. 11. TELECOM ROOM DOORS TO BE FAIL SECURE, ALL OTHER SHALL BE FAIL SAFE. ALL CARD READERS WILL BE TIED TO THE LIFE SAFETY SYSTEM AND WILL MEET THE REQUIREMENTS OF THE STATE CODE. 12. G.C. WILL BE RESPONSIBLE TO TOUCH-UP THE STAIN AND FINISH OF REUSED, SALVAGED DOORS TO A "LIKE -NEW" APPEARANCE. FINISH ON EXISTING GLASS SUITE ENTRY DOORS TO BE POLISHED AND RETURNED TO A "LIKE -NEW" FINISH. 13. ALL CLOSERS TO BE ADA COMPLIANT. 14. NEW HARDWARE TO MATCH EXISTING IN FINISH AND STYLE. THE GRADE OF HARDWARE MUST BE EQUAL OR BETTER THAN EXISTING. 15. G.C. TO PAINT ALL EXISTING DOOR FRAMES TO REMAIN "P2" AND ALL EXISTING PAINT GRADE DOOR TO REMAIN "P2". FRAME TYPES SCALE: 3/8" = 1'-0" 2" 31-0" 2" CV O CV 2"1'-6" 2" 31-0" 2" O F CV O z I-- 1/4' =1/4" CLEAR co TEMPERED GLASS w (TYP.) _ U Q 2" 6'-0" 2" O H E L L Y E R L E W I S= ARCHITECTURE INTERIOR DESIGN �M�v° e�hKorg"�rarm�r 21 ��", a� 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty w Mutual® INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Door and Hardware Schedules No. A-5.00 Drawn by: CM/SP Checked by: KS A pproved by: KB Client Approval: Date: Issue For Bid: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: As Noted Drawing: Door and Hardware Schedules No. A-5.00