HomeMy WebLinkAbout04741 A-5.00HARDWARE SCHEDULE
SET #1 - CLOSET PASSAGE LATCHSET (SINGLE DOOR) SET #7 - ELECTRIC STRIKE WITH CLOSER
2 PAIR HINGES
1 LATCHSET
1 OVERHEAD STOP
4 RUBBER SILENCERS
4 1/2" ANTI -FRICTION BEARING HINGES
FINISH: MATCH EXISTING
BLDG. STD. PASSAGE LEVER LATCHSET
FINISH: MATCH EXISTING
"RIXSON" #10 SERIES OVERHEAD STOP
FINISH: MATCH EXISTING
SET #2 - PASSAGE LATCHSET
2 PAIR HINGES
1 LATCHSET
4 RUBBER SILENCERS
4 1/2" ANTI -FRICTION BEARING HINGES
FINISH: MATCH EXISTING
BLDG. STD. LEVER PASSAGE LATCHSET
FINISH: MATCH EXISTING
SET #3 - CLASSROOM LOCKSET (SINGLE)
2 PAIR HINGES
1 LOCKSET
1 FLOOR STOP
4 RUBBER SILENCERS
4 1/2" ANTI -FRICTION BEARING HINGES
FINISH: MATCH EXISTING
BLDG. STD. LEVER CLASSROOM LOCKSET
FINISH: MATCH EXISTING
"RIXSON" #10 SERIES FLOOR STOP
FINISH: MATCH EXISTING
SET #4 - STOREROOM LOCKSET WITH CLOSER
2 PAIR HINGES
4 1/2" ANTI -FRICTION BEARING HINGES
FINISH: MATCH EXISTING
FINISH: MATCH EXISTING
1 LOCKSET
BLDG. STD. LEVER STOREROOM LOCKSET
SERIES (PULL SIDE MOUNTED) WITH 72MC
FINISH: MATCH EXISTING
1 CLOSER W/HOLD
ADA COMPLIANT "LCN CLOSERS" OR EQUAL: 4040XP
OPEN
SERIES SMOOTHIE (PULL -SIDE OR PULL MOUNTED)
HES, SERIES 1006CS , .25 AMPS @ 24VDC
FINISH: POWDER COAT FINISH: MATCH EXISTING
1 FLOOR STOP
"IVES" #436
FINISH: MATCH EXISTING
FINISH: MATCH EXISTING
4 RUBBER SILENCERS
SET #5 - CLOSET
DUMMY TRIM (PAIR OF DOORS)
4 PAIR HINGES
4 1/2" ANTI -FRICTION BEARING HINGES
SUPPLY AS REQUIRED. COORDINATE WITH
FINISH: MATCH EXISTING
2 DUMMY TRIM
BLDG. STD. LEVER DUMMY TRIM
FINISH: MATCH EXISTING
2 MAGNETIC CATCHES
2 OVERHEAD STOPS "RIXSON" #10 SERIES OVERHEAD STOP
FINISH: MATCH EXISTING
4 RUBBER SILENCERS
SET #6 - ENTRANCE LOCKSET WITH CLOSER
2 PAIR HINGES
1 LOCKSET
1 CLOSER
1 FLOOR STOP
4 RUBBER SILENCERS
DOOR TYPES
SCALE: 3/8" = 1'-0"
4 1/2" ANTI -FRICTION BEARING HINGES
FINISH: MATCH EXISTING
BLDG. STD. LEVER ENTRANCE LOCKSET
FINISH: MATCH EXISTING
ADA COMPLIANT "LCN CLOSERS" OR EQUAL: 4040XP
SERIES (PULL -SIDE MOUNTED)
FINISH: POWDER COAT TO MATCH EXISTING
"IVES" #438
FINISH: MATCH EXISTING
BY GENERAL CONTRACTOR:
2 PAIR HINGES
1 CLOSER
1 ELEC. STRIKE
1 LOCKSET
1 POWER SUPPLY
1 FLOOR STOP
4 1/2" ANTI -FRICTION BEARING HINGES
RELEASES IFR �mW3TRlllCTI�N
FINISH: MATCH EXISTING
2 HINGES
"ADA COMPLIANT LCN CLOSERS" OR EQUAL:
4040XP
SERIES (PULL SIDE MOUNTED) WITH 72MC
METAL
COVER
IC'Itp� o�F Cairrnrel
FINISH: MATCH EXISTING
Dr�TEa 02/23/18
HES, SERIES 1006CS , .25 AMPS @ 24VDC
WITH HES
SMART PAC III ON FAIL SAFE HARDWARE
1 ELEC. STRIKE
FINISH: MATCH EXISTING
BLDG. STD. STOREROOM LEVER LOCKSET
FINISH: MATCH EXISTING
1 LOCKSET
GC TO PROVIDE ALL POWER TO STRIKE
POWER
SUPPLY AS REQUIRED. COORDINATE WITH
SECURITY
VENDOR
Thk.
"IVES" #438
1 POWER SUPPLY
FINISH: MATCH EXISTING
Mat.
4 RUBBER SILENCERS
BY TENANT'S SECURITY VENDOR
1 CARD READER
1 MOTION DETECTOR DEVICE
INSTALLATION TO BE COORDINATED WITH THE LANDLORD. PROVIDE 24V DC
POWER. CORRIDOR TRIM IS ELECTRICALLY UNLOCKED BY CARD READER OR KEY
OVERRIDE. INTERIOR TRIM IS ALWAYS FREE FOR IMMEDIATE EGRESS. TELECOM
ROOMS TO BE FAIL-SAFE. ALL OTHER ROOMS TO BE FAIL-SAFE. AS REQUIRED,
ACCESS CONTROLLED DOORS WILL BE TIED TO THE LIFE SAFETY SYSTEM
REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. ALL ACCESS
CONTROLLED DOORS WILL MEET THE REQUIREMENTS OF INDIANA STATE CODE.
G.C. TO COORDINATE "J" BOX LOCATION FOR THE CARD READERS WITH
TENANT'S SECURITY VENDOR.
SET #e - ELECTRIC STRIKE WITH CLOSER (MOTHER'S ROOM)
BY GENERAL CONTRACTOR:
RELEASES IFR �mW3TRlllCTI�N
Frame
2 HINGES
4 1/2" ANTI -FRICTION BEARING HINGES
5uuh�j�o�ktio a"mipdiian�c®wlNo ®III r�gwf�timns
FINISH: SATIN CHROME
1 CLOSER
"ADA COMPLIANT LCN CLOSERS" OR EQUAL: 4040XP
IC'Itp� o�F Cairrnrel
SERIES (PUSH SIDE MOUNTED) WITH 72MC
Dr�TEa 02/23/18
METAL COVER
Nick Mishler
FINISH: SATIN CHROME
1 ELEC. STRIKE
HES, SERIES 1006CS , .25 AMPS @ 24VDC WITH HES
SMART PAC III ON FAIL SAFE HARDWARE
FINISH: SATIN CHROME
1 LOCKSET
SCHLAGE L SERIES MORTISE OR APPROVED EQUAL
Label
VACANT/OCCUPIED THUMBTURN INDICATOR W/
Width
ESCUTCHEON TRIM
Thk.
FINISH: SATIN CHROME
1 POWER SUPPLY
GC TO PROVIDE ALL POWER TO STRIKE POWER
Mat.
SUPPLY AS REQUIRED. COORDINATE WITH SECURITY
No.
VENDOR
1 FLOOR STOP
"IVES" #438
FINISH: SATIN CHROME
4 RUBBER SILENCERS
BY TENANT'S SECURITY VENDOR:
1 CARD READER
1 MOTION DETECTOR DEVICE
INSTALLATION TO BE COORDINATED WITH THE LANDLORD. PROVIDE 24V DC
POWER. CORRIDOR TRIM IS ELECTRICALLY UNLOCKED BY CARD READER OR KEY
OVERRIDE. INTERIOR TRIM IS ALWAYS FREE FOR IMMEDIATE EGRESS. AS
REQUIRED, ACCESS CONTROLLED DOORS WILL BE TIED TO THE LIFE SAFETY
SYSTEM REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. ALL
ACCESS CONTROLLED DOORS WILL MEET THE REQUIREMENTS OF INDIANA STATE
CODE. G.C. TO COORDINATE "J" BOX LOCATION FOR THE CARD READERS WITH
TENANT'S SECURITY VENDOR.
DOOR SCHEDULE
First Floor
RELEASES IFR �mW3TRlllCTI�N
Frame
L Y E R
��;�,����
,. �
5uuh�j�o�ktio a"mipdiian�c®wlNo ®III r�gwf�timns
W
rn95tal� emd Ilmeal Or'"dle��
Remarks
IC'Itp� o�F Cairrnrel
"���
Dr�TEa 02/23/18
Date:
Nick Mishler
DOOR SCHEDULE
First Floor
Door
Frame
L Y E R
L
E
W
Hardware Set
Remarks
Client Approval:
Date:
Door No.
Room No.
Label
Type
Width
Height
Thk.
Mat.
Finish
Type
Mat.
Finish
No.
401A
401
-
A
SINGLE
MATCH
1-3/4"
SC. WD.
ST -1
2
H.M.
P2
6
3,_0"
EX.
401B
401
-
D
SINGLE
MATCH"
1-3/4
SC. WD./
ST -1
1
H.M.
P2
7
31-0"
EX.
TEMP. GL
401C
401
-
D
SINGLE
MATCH"
1-3/4
SC. WD./
ST -1
1
H.M.
P2
7
31-0"
EX.
TEMP. GL
402
402
-
A
SINGLE
MATCH
1-3/4"
SC. WD.
ST -1
1
H.M.
P2
4
31_0"
ET.
403
403
-
A
SINGLE
MATCH
1-3/4"
SC. WD.
ST -1
1
H.M.
P2
7
31_0"
ET.
404
404
-
A
SINGLE
MATCH
1-3/4"
SC. WD.
ST -1
1
H.M.
P2
1
31-0"
EX.
405
405
-
A
SINGLE
MATCH
1-3/4"
SC. WD.
ST -1
1
H.M.
P2
4
3,-0
EX
407
407
-
A
SINGLE
MATCH
1_3/4"
SC. WD.
ST -1
1
H.M.
P2
2
310.EX.
415
415
-
A
SINGLE
MATCH
1-3/4"
SC .WD.
ST -1
2
H.M.
P2
2
3,_0"
EX.
416
416
-
A
SINGLE
MATCH
1-3/4"
SC. WD.
ST -1
1
H.M.
P2
8
31-0"
EX.
424
424
-
C
DOUBLE
(2)3'-0"
MATCH
EX.
1-3/4"
SC. WD.
ST -1
3
H.M.
P2
5
ADJUST EXISTING HARDWARE
428
428
-
A
EX.
EX.
EX.
EX.
EX.
EX.
EX.
P2
7
AS NECESSARYTO CONFORM
TO HARDWARE SET #7.
432
432
-
A
SINGLE
MATCH
1-3/4"
SC .WD.
ST -1
2
H.M.
P2
3
3.-0"
EX.
436
436
-
B
SINGLE
MATCH"
1-3/4
SC. WD./
ST -1
1
H.M.
P2
7
31-0"
EX.
TEMP. GL.
441
441
-
C
()3BoE
M ATETCH
1-3/4"
SC .WD.
ST -1
3
H.M.
P2
5
443
443
-
A
SINGLE
MATCH
1-3/4"
SC .WD.
ST -1
2
H.M.
P2
2
31-0"
EX.
445
445
-
A
SINGLE
MATCH
1-3/4"
SC .WD.
ST -1
2
H.M.
P2
2
31-0"
EX.
DOOR AND HARDWARE NOTES
1. G.C. TO PROVIDE CUT -SHEETS OF ALL HARDWARE PROPOSED, FOR ARCHITECT'S REVIEW, PRIOR TO ORDERING.
2. G.C. TO COORDINATE HARDWARE PURCHASE, SPECIFICATION AND INSTALLATION WITH BUILDING MANAGEMENT.
3. FURNISH 2 PAIR HINGES PER LEAF, UNLESS OTHERWISE NOTED. FURNISH HINGES WITH STAINLESS STEEL PINS AND CONCEALED BEARINGS. SIZE LISTED
IN HARDWARE SETS INDICATES HEIGHT.
4. FURNISH SILENCERS FOR ALL INTERIOR FRAMES; 3 FOR SINGLE DOORS, 4 FOR PAIR OF DOORS. OMIT WHERE SOUND OR LIGHT SEAL OCCURS.
5. ALL LEVER SETS TO BE 3'-3" FROM THE BOTTOM OF THE DOOR TO THE CENTER OF THE LEVER.
6. INSTALL EACH HARDWARE ITEM PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. DO NOT INSTALL SURFACE MOUNTED ITEMS UNTIL
FINISHES HAVE BEEN COMPLETED ON THE SUBSTRATE. SET UNITS LEVEL, PLUM AND TRUE TO LINE AND LOCATION.
7. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE
UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY.
8. KEYING OF CYLINDER LOCKS SHALL BE COORDINATED WITH THE OWNER, FOR ESTIMATE USE GRANDMASTER KEYING CHARGE. UNDER OWNER'S
DIRECTION, KEY TO NEW OR EXISTING SYSTEM TO BE APPROVED BY OWNER'S REPRESENTATIVE IN WRITING. FURNISH CONSTRUCTION KEY SYSTEM
WITH KEYS THAT CAN BE RENDERED INOPERATIVE BY THE TURN OF A CHANGE KEY. STAMP ALL KEYS "DO NOT DUPLICATE". FOR PROTECTION OF
THE OWNER, ALL LOCKS AND CYLINDERS SHALL BE KEYED AT THE FACTORY OF THE LOCK MANUFACTURER WHERE PERMANENT RECORDS ARE
MAINTAINED.
9. LIBERTY MUTUAL SHALL RECEIVE THREE KEYS FOR EACH LOCK AND SIX MASTER KEYS FOR EACH SET. REVIEW WITH LANDLORD OR BUILDING MANAGER IF
THEY REQUIRE A BUILDING APPROVED LOCKSMITH FOR ALL KEY AND LOCK WORK.
10. ALL EXIT DOORS SCHEDULED WITH ELECTRONIC HARDWARE SHALL UNLOCK UPON THE ACTUATION OF A LIFE SAFETY DEVICE. ALL DOORS REQUIRED AS
EXITS WITH ELECTRONIC HARDWARE UNLOCK UPON THE LOSS OF POWER CONTROLLING THE LOCK OR LOCK MECHANISM. ALL DOORS REQUIRED AS
EXITS WITH ELECTRONIC HARDWARE SHALL HAVE THE CAPABILITY OF BEING UNLOCKED BY A SIGNAL FROM THE FIRE COMMAND CENTER IN HIGH RISE
BUILDING WHERE APPLICABLE.
11. TELECOM ROOM DOORS TO BE FAIL SECURE, ALL OTHER SHALL BE FAIL SAFE. ALL CARD READERS WILL BE TIED TO THE LIFE SAFETY SYSTEM AND
WILL MEET THE REQUIREMENTS OF THE STATE CODE.
12. G.C. WILL BE RESPONSIBLE TO TOUCH-UP THE STAIN AND FINISH OF REUSED, SALVAGED DOORS TO A "LIKE -NEW" APPEARANCE. FINISH ON EXISTING
GLASS SUITE ENTRY DOORS TO BE POLISHED AND RETURNED TO A "LIKE -NEW" FINISH.
13. ALL CLOSERS TO BE ADA COMPLIANT.
14. NEW HARDWARE TO MATCH EXISTING IN FINISH AND STYLE. THE GRADE OF HARDWARE MUST BE EQUAL OR BETTER THAN EXISTING.
15. G.C. TO PAINT ALL EXISTING DOOR FRAMES TO REMAIN "P2" AND ALL EXISTING PAINT GRADE DOOR TO REMAIN "P2".
FRAME TYPES
SCALE: 3/8" = 1'-0"
2" 31-0" 2"
CV
O
CV
2"1'-6" 2" 31-0" 2"
O
F
CV
O
z
I--
1/4'
=1/4" CLEAR co
TEMPERED GLASS w
(TYP.) _
U
Q
2" 6'-0" 2"
O
H
E
L
L Y E R
L
E
W
I S=
ARCHITECTURE
INTERIOR DESIGN
�M�v° e�hKorg"�rarm�r
21 ��",
a�
2 1 1 South 12th St.
Phila., PA 1 9107
21 5.922.7066
THE GENERAL CONTRACTOR IS RESPONSIBLE
TO VERIFY ALL DIMENSIONS ON SITE AND
CONFIRM SUCH DIMENSIONS AGAINST ACTUAL
SITE CONDITIONS. THE GENERAL CONTRACT—
OR SHALL COORDINATE ALL WORK AND
RELATED TRADES, AND SHALL NOTIFY THE
ARCHITECT OF ANY INTERFERENCE OF
MECHANICAL, ELECTRICAL, OR PLUMBING
WORK WITH THE ARCHITECTURAL WORK AND
OF ANY CONFLICTS OR DISCREPANCIES IN
DIMENSIONS AGAINST ON SITE CONDITIONS
PRIOR TO PROCEEDING WITH THE WORK OR
PROCUREMENT OF MATERIALS.
Project:
Liberty
w
Mutual®
INSURANCE
450 East 96th St
4th Floor
Indianapolis IN 46240
Project No: 047.41
Drawing:
Door and
Hardware
Schedules
No. A-5.00
Drawn by:
CM/SP
Checked by:
KS
A pproved by:
KB
Client Approval:
Date:
Issue For Bid:
01/26/18
Issue For Permit: 01/29/18
No.
Date
Revision
Scale:
As Noted
Drawing:
Door and
Hardware
Schedules
No. A-5.00