HomeMy WebLinkAbout04741 MEP ENG DOCS (sealed)LUMINAIRE SCHEDULE SYMBOL LAMPS CR CARD READER FM`51 MANUFACTURER FD_1B1 TYPE ES WATTAGE VOLTAGE DESCRIPTION AND CATALOG REMARKS C O b RECEPTACLE SYMBOL WITH ADDITIONAL SUBSCRIPT DESIGNATES TYPE OR SPECIFIC ABOVE FINISH GRADE No. TYPE "AC" INDICATES MOUNTED 8" ABOVE COUNTER UNLESS NOTED OTHERWISE ON $X ARCHITECTURAL ELEVATIONS NUMBER +48 RECEPTACLE MOUNTED AT HEIGHT INDICATED Q JUNCTION BOX - SIZE PER N.E.C. ARTICLE 314 REQUIREMENTS ® NEMA L14 -30R RECEPTACLE ® L.E.D. 2'x4' LAY -IN WITH CURVED CENTER SATINE LENS, WHITE FINISH, AND STANDARD PINNACLE: THREE(3) STUBBED CONDUITS FOR POWER, DATA AND AV. FIRE SAFE TO ORIGINAL FLOOR A - LED 3500'K 41 UNV 0-10V DIMMING DRIVER. #AD24-A-835HO-XX-U-OL1 -1 -0-W POWER: ONE 1/2" CONDUIT STUB. OS DATA: ONE 3/4" CONDUIT STUB MOTOR CONTROL CENTER AV: ONE 1-1/4" CONDUIT STUB AUTOMATIC TRANSFER SWITCH 6" 2 HOUR FIRE RATED POKE THROUGH: LEGRAND WIREMOLD #6AT SERIES WITH ONE(1) SIDE O COMPARTMENT MOUNTED 125VAC-20AMP DUPLEX RECEPTACLE #68REC WITH BOTTOM FEED AUTOMATIC TEMPERATURE CONTROL 1/2 GANG 3/4" CONDUIT HOUSING ASSEMBLY #575CHA, ONE(1) CENTER COMPARTMENT MISCELLANEOUS MOUNTED EIGHT(8) PORT COMMUNICATIONS DEVICE PLATE #6ACT8A AND ONE(1) SIDE AMERICAN WIRE GAUGE SAME AS TYPE "A", EXCEPT WITH SELF CONTAINED EMERGENCY LIGHTING BATTERY PACK. PINNACLE: CONDUIT BOTTOM HOUSING #1100CHA AND HALF GANG BLANK BOTTOM HOUSING #SBLH. AE _ LED 3500'K 41 UNV AS INDICATED ON PLAN. PROVIDE CONDUIT WITH PULLSTRING AND INSULATING BUSHING. #AD24-A-835HO-XX-U-OL1-1-11-W WALL MOUNTED POWER OUTLET (4-11/16" SQUARE x 2-1/8" DEEP JUNCTION BOX) BUILDING MANAGEMENT SYSTEM COMPLETE WITH SINGLE GANG DEVICE RING AND COVER PLATE(COLOR SELECTION BY ASSOCIATION ARCHITECT) TO ACCEPT FURNITURE WHIP. PROVIDE ALL NECESSARY APPURTENANCES CONDUIT INCLUDING WHIP IF REQUIRED AND MAKE FINAL CONNECTIONS TO SYSTEMS FURNITURE. MOUNT NATIONAL FIRE PROTECTION ASSOCIATION AT 8" A.F.F. UNLESS NOTED OTHERWISE. (Ti WALL MOUNTED TELECOMMUNICATIONS JUNCTION BOX FOR CONNECTION TO SYSTEMS NOT IN CONTRACT FURNITURE. JUNCTION BOX SHALL BE 4-11/16" SQUARE x 3" DEEP COMPLETE WITH SINGLE CABINET UNIT HEATER SAME AS TYPE "A", EXCEPT 2'x2' PINNACLE: STUBBED 12" INTO ACCESSIBLE CEILING SPACE. MOUNT AT 8" A.F.F. UNLESS NOTED Al- OTHERWISE. LED 3500'K 20 UNV FLUSH FLOOR MOUNTED POWER AND TELECOM FIRE RATED POKE -THROUGH #AD22-A-835LO-XX-U-OL1-1-0-W DEVICE WITH FURNITURE FEED COVER PLATE. HUBBELL SYSTEM ONE "FRPT" - 4 CIRCUIT INCH, ONE PIECE POKE -THROUGH WITH 3/4" CONDUIT STEM FOR POWER AND NOT TO SCALE 1-1/2" CONDUIT STEM FOR VOICE/DATA; #S1SPFFXX COVER PLATE. PROVIDE CENTERLINE ONE 1-1/2" CONDUIT (FOR TELECOM) BELOW FLOOR TO NEAREST WALL AND POLE EXTEND TO 12" ABOVE ACCESSIBLE CEILING OF FLOOR. VERIFY COVER PLATE CURRENT LIMITING FUSE COLOR WITH ARCHITECT. ®T SAME AS 00, EXCEPT ONLY 1-1/2" VOICE/DATA CONDUIT UTILIZED. OS SAME AS TYPE "Al ", EXCEPT WITH SELF CONTAINED EMERGENCY LIGHTING BATTERY PACK. PINNACLE: CPT A E - LED 3500K 20 UNV PT #AD22-A-835LO-XX-U-OL1-1-1I-W CU COPPER PVC POLYVINYL CHLORIDE EF EXHAUST FAN RMC RIGID METAL CONDUIT EM EMERGENCY RMS ROOT MEAN SQUARED EMT ELECTRICAL METALLIC TUBING L.E.D. 6" DIAMETER RECESSED DOWNLIGHT WITH CLEAR SEMI SPECULAR H.E. WILLIAMS: EPO C - LED 3500'K 19 UNV REFLECTOR WITH WIDE DISTRIBUTION AND STANDARD DRIVER. #L60-Ll5C-835-CS-W-DRV-277 EWC ELECTRIC WATER COOLER SP SPARE F FUSE SWD SWITCH DUTY (RATED) FCU FAN COIL UNIT SYM SYMMETRICAL FLA FULL LOAD AMPERES SAME AS TYPE "C", EXCEPT WITH SELF CONTAINED EMERGENCY LIGHTING BATTERY PACK. H.E. WILLIAMS: FMC FLEXIBLE METAL CONDUIT TMCB LED FNMC FLEXIBLE NON-METALLIC CONDUIT TMGB #L60-Ll5C-835-CS-W-DIM-277-EM/12W FT CE _ 350D 19 277 UH UNIT HEATER GND, G GROUND OR GROUNDING UL UNDERWRITERS LABORATORIES GRMC GALVANIZED RIGID METALLIC CONDUIT SAME AS TYPE "C", EXCEPT WITH DIMMING DRIVER. H.E. WILLIAMS: HACR CD _ LED 350D 19 277 W #L60-Ll5C-835-CS-W-DIM-277 HOA HAND, OFF, AUTOMATIC SWITCH WH WATER HEATER IEEE INSTITUTE OF ELECTRICAL & ELECTRONIC INCANDESCENT PENDANT MOUNT WITH "SPIRAL NEST" SHADE. WHITE CANOPY RIDGELY STUDIO WERKS: VERIFY CORD LENGTH WITH ARCHITECT D 1 60 T10 60 120 AND CORD SET AND GREEN FINISH. #SPIRAL NEST IN INCHES WYE INT INTERLOCK 0 PHASE K KILO/THOUSAND KCMIL THOUSAND CIRCULAR MILS L.E.D. SELF POWERED BATTERY BACK-UP DIE CAST ALUMINUM EXIT SIGN. BRUSHED CHLORIDE: ALUMINUM FACE WITH BLACK HOUSING AND RED LETTERING. MOUNTING CONFIGURATION, # CAD -N -U -R -A }e� - LED 4 120/277 FACES AND DIRECTIONAL ARROWS AS INDICATED ON PLANS. 1. THE ELECTRICAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO COORDINATE AND VERIFY WITH THE ARCHITECT AND ALL ARCHITECTURAL DRAWINGS SUCH AS FLOOR PLANS CEILING PLANS SCHEDULES ELEVATIONS SECTIONS DETAILS ETC., ALL CEILING TYPES, CONFIGURATIONS AND SPECIFICATIONS, LUMINAIRE COLORS AND FINISHES, LENGTHS, TRIMS, MOUNTINGS, MOUNTING SYSTEMS/HARDWARE, LUMINAIRE CONFIGURATIONS/STYLES/SHAPES, HEIGHT OF SUSPENDED AND WALL MOUNTED LUMINAIRES, ETC. PRIOR TO SHOP DRAWING SUBMITTALS, ANY ROUGH -INS, AND PLACING FINAL PURCHASE ORDERS. . 2. VERIFY FINAL LUMINAIRE LOCATIONS WITH OTHER CEILING MOUNTED EQUIPMENT SUCH AS DIFFUSERS, FIRE ALARM DEVICES, SPEAKERS, ETC. WITH ARCHITECTURAL RCP (REFLECTED CEILING PLANS). 3. VERIFY EXACT HEIGHT AND LOCATIONS OF ALL WALL MOUNTED AND PENDANT/CABLE MOUNTED LUMINAIRES WITH ARCHITECTURAL ELEVATIONS PRIOR TO ANY ROUGH -IN. 4. LUMINAIRES SHALL NOT BE SUPPORTED FROM SUSPENDED CEILING SUPPORTS UNLESS ADDITIONAL CEILING FRAMING AND SUPPORTS ARE ADDED BY THE CEILING CONTRACTOR ACCORDING TO MANUFACTURER'S RECOMMENDATIONS, U.L. LISTINGS, AND ANY APPLICABLE STATE OR LOCAL CODES. 5. CONNECTIONS TO RECESSED LUMINAIRES SHALL BE MADE WITH MINIMUM 1/2" FLEXIBLE METAL CONDUIT (FMC) FROM FIXTURE TO OUTLET BOX. LENGTH OF FMC SHALL NOT EXCEED 6'. 6. AT THE CONCLUSION OF THE WORK, EACH LUMINAIRE MUST BE CLEANED PER MANUFACTURER'S INSTRUCTIONS, EQUIPPED WITH THE PROPER TYPE, NUMBER OF LAMPS, INCLUDING KELVIN TEMPERATURE AND WATTAGE, AND ALL IN GOOD OPERATING CONDITION. DOOR ACCESS CONTROL SYMBOL LEGEND SYMBOL DESCRIPTION CR CARD READER FM`51 MOTION DETECTOR FD_1B1 DOOR BELL ES ELECTRIC STRIKE RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes ICltp at Caimal ntro DATE: 02/23/18 TELECOMMUNICATION OUTLET SYMBOL LEGEND SYMBOL I DESCRIPTION V COMBINATION VOICE/DATA OUTLET (4-11/16" x 2-1/8" DEEP JUNCTION BOX) COMPLETE WITH SINGLE GANG DRY WALL RING (VERIFY DRYWALL THICKNESS) MOUNTED AT 18" A.F.F. PROVIDE 3/4" CONDUIT WITH INSULATING BUSHING AND PULLSTRING STUBBED UP 12" INTO ACCESSIBLE CEILING SPACE. V VOICE (TELEPHONE) OUTLET (4-11/16" x 2-1/8" DEEP JUNCTION BOX) COMPLETE WITH SINGLE GANG DRY WALL RING (VERIFY DRYWALL THICKNESS) MOUNTED AT 18" A.F.F. PROVIDE 3/4" CONDUIT WITH INSULATING BUSHING AND PULLSTRING STUBBED UP 12" INTO ACCESSIBLE CEILING SPACE. 0 DATA OUTLET (4-11/16" x 2-1/8" DEEP JUNCTION BOX) COMPLETE WITH SINGLE GANG DRY WALL RING (VERIFY DRYWALL THICKNESS) MOUNTED AT 18" A.F.F. PROVIDE 3/4" CONDUIT WITH INSULATING BUSHING AND PULLSTRING STUBBED UP 12" INTO ACCESSIBLE CEILING SPACE. FAV71 SINGLE GANG MUD RING WITH TWO PULL STRINGS AT 18" AFF WITH 1-1/4" CONDUIT TO THE FLOOR STUB BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED FACEPLATES. AV2 CHIEF MFG. PAC526 WITH TWO PULL STRINGS WITH 1-1/4" CONDUIT TO THE PLENUM. BOX BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED FACEPLATES. MOUNTING HEIGHT AS INDICATED ON PLANS. VOICE AND/OR DATA SYMBOL WITH ADDITIONAL SUBSCRIPT DESIGNATES TYPE OR SPECIFIC REQUIREMENTS AS FOLLOWS: "AC" INDICATES MOUNTED 8" ABOVE COUNTER UNLESS NOTED OTHERWISE ON ARCHITECTURAL ELEVATIONS "+48" SPECIFIC MOUNTING HEIGHT OF DEVICE "TV" DENOTES TELEVISION OUTLET ® TELECOMMUNICATION BACKBOARD - 3/4" PLYWOOD - 8'-0" HIGH x LENGTH OF WALL AS INDICATED - PAINTED WITH TWO COATS OF FIRE RESISTANT PAINT ON ALL SIX SIDES WIRING DEVICE SYMBOL LEGEND SYMBOL DESCRIPTION 6 DUPLEX RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDING TYPE MOUNTED ABOVE COUNTER AT 18" AFF UNLESS NOTED OTHERWISE ° DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDING TYPE Al MOUNTED AT 18" AFF UNLESS NOTED OTHERWISE KILOWATTS GFCI GROUND TYPE DUPLEX RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, ABOVE FINISH FLOOR GROUNDING TYPE MOUNTED AT 18" AFF UNLESS NOTED OTHERWISE C O b RECEPTACLE SYMBOL WITH ADDITIONAL SUBSCRIPT DESIGNATES TYPE OR SPECIFIC ABOVE FINISH GRADE REQUIREMENTS AS FOLLOWS: LIGHTING "AC" INDICATES MOUNTED 8" ABOVE COUNTER UNLESS NOTED OTHERWISE ON $X ARCHITECTURAL ELEVATIONS LIQUID TIGHT FLEXIBLE METAL CONDUIT +48 RECEPTACLE MOUNTED AT HEIGHT INDICATED Q JUNCTION BOX - SIZE PER N.E.C. ARTICLE 314 REQUIREMENTS ® NEMA L14 -30R RECEPTACLE ® NEMA L6 -20R RECEPTACLE - THREE(3) STUBBED CONDUITS FOR POWER, DATA AND AV. FIRE SAFE TO ORIGINAL FLOOR ALUMINUM CONSTRUCTION AND FIRE RATING AS REQUIRED IN ACCORDANCE WITH ARCHITECTURAL MAIN CIRCUIT BREAKER SPECIFICATIONS. COORDINATE LOCATION WITH ARCHITECT AND FURNITURE VENDOR PRIOR TO AMERICAN NATIONAL STANDARDS INSTITUTE CORING FOR COORDINATION WITH THE TABLE LEG.. MOLDED CASE CIRCUIT BREAKER POWER: ONE 1/2" CONDUIT STUB. OS DATA: ONE 3/4" CONDUIT STUB MOTOR CONTROL CENTER AV: ONE 1-1/4" CONDUIT STUB AUTOMATIC TRANSFER SWITCH 6" 2 HOUR FIRE RATED POKE THROUGH: LEGRAND WIREMOLD #6AT SERIES WITH ONE(1) SIDE O COMPARTMENT MOUNTED 125VAC-20AMP DUPLEX RECEPTACLE #68REC WITH BOTTOM FEED AUTOMATIC TEMPERATURE CONTROL 1/2 GANG 3/4" CONDUIT HOUSING ASSEMBLY #575CHA, ONE(1) CENTER COMPARTMENT MISCELLANEOUS MOUNTED EIGHT(8) PORT COMMUNICATIONS DEVICE PLATE #6ACT8A AND ONE(1) SIDE AMERICAN WIRE GAUGE COMPARTMENT MOUNTED BLANK MOUNTING PLATE #68B WITH BOTTOM FEED ONE GANG 1" MAIN LUGS ONLY CONDUIT BOTTOM HOUSING #1100CHA AND HALF GANG BLANK BOTTOM HOUSING #SBLH. BUILDING AUTOMATION SYSTEM PROVIDE WITH SURFACE STYLE COVER ASSEMBLY #6CTC2XX. FINISH COLOR BY ARCHITECT. NATIONAL ELECTRIC CODE PROVIDE 12" RADIUS 2" CONDUIT ELBOW AND RUN CONDUIT IN WALL TO 6" ABOVE CEILING BELOW FINISH GRADE AS INDICATED ON PLAN. PROVIDE CONDUIT WITH PULLSTRING AND INSULATING BUSHING. (Pi WALL MOUNTED POWER OUTLET (4-11/16" SQUARE x 2-1/8" DEEP JUNCTION BOX) BUILDING MANAGEMENT SYSTEM COMPLETE WITH SINGLE GANG DEVICE RING AND COVER PLATE(COLOR SELECTION BY ASSOCIATION ARCHITECT) TO ACCEPT FURNITURE WHIP. PROVIDE ALL NECESSARY APPURTENANCES CONDUIT INCLUDING WHIP IF REQUIRED AND MAKE FINAL CONNECTIONS TO SYSTEMS FURNITURE. MOUNT NATIONAL FIRE PROTECTION ASSOCIATION AT 8" A.F.F. UNLESS NOTED OTHERWISE. (Ti WALL MOUNTED TELECOMMUNICATIONS JUNCTION BOX FOR CONNECTION TO SYSTEMS NOT IN CONTRACT FURNITURE. JUNCTION BOX SHALL BE 4-11/16" SQUARE x 3" DEEP COMPLETE WITH SINGLE CABINET UNIT HEATER GANG DEVICE RING AND 1-1/2" CONDUIT WITH INSULATING BUSHING AND PULLSTRING NORMALLY CLOSED STUBBED 12" INTO ACCESSIBLE CEILING SPACE. MOUNT AT 8" A.F.F. UNLESS NOTED CIRCUIT BREAKER OTHERWISE. ©T POWER AND TELECOM FURNITURE FEED FLOOR BOX FIRE RATED OR POKE -THROUGH DEVICE. CERTIFIED BALLASTS MANUFACTURERS FLUSH FLOOR MOUNTED POWER AND TELECOM FIRE RATED POKE -THROUGH NORMALLY OPEN DEVICE WITH FURNITURE FEED COVER PLATE. HUBBELL SYSTEM ONE "FRPT" - 4 CIRCUIT INCH, ONE PIECE POKE -THROUGH WITH 3/4" CONDUIT STEM FOR POWER AND NOT TO SCALE 1-1/2" CONDUIT STEM FOR VOICE/DATA; #S1SPFFXX COVER PLATE. PROVIDE CENTERLINE ONE 1-1/2" CONDUIT (FOR TELECOM) BELOW FLOOR TO NEAREST WALL AND POLE EXTEND TO 12" ABOVE ACCESSIBLE CEILING OF FLOOR. VERIFY COVER PLATE CURRENT LIMITING FUSE COLOR WITH ARCHITECT. ®T SAME AS 00, EXCEPT ONLY 1-1/2" VOICE/DATA CONDUIT UTILIZED. OS CEILING MOUNTED SPEAKER LIGHTING SYMBOL LEGEND SYMBOL DESCRIPTION A AC ABOVE COUNTER RECESSED 2'x4' LUMINAIRE. "A" INDICATES TYPE; "a" INDICATES SWITCH CONTROL. REFER TO ° LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION. Al KW KILOWATTS RECESSED 2'x2' LUMINAIRE. "Al" INDICATES TYPE. REFER TO LUMINAIRE SCHEDULE FOR ABOVE FINISH FLOOR ADDITIONAL INFORMATION. C O b RECESSED DOWN LIGHT. "C" INDICATES LUMINAIRE TYPE; "b" INDICATES SWITCH CONTROL ABOVE FINISH GRADE REFER TO LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION. LIGHTING LIGHT SWITCH. SINGLE POLE, 20 AMPERE, 120/277 VOLT, 1 HP. $X LIGHT SWITCH. "X" INDICATES THE FOLLOWING: LIQUID TIGHT FLEXIBLE METAL CONDUIT "a" CONTROL OF INDICATED LUMINAIRES AIR HANDLING UNIT "VD" WALLBOX PIR VAVANCY SENSOR WITH 0-10V DIMMING AND AMBIENT LIGHT MAKE-UP AIR UNIT DETECTION SENSOR. LUTRON #MS -Z101 -V -WH AMPERE INTERRUPTING CAPACITY 'VS" WALLBOX DUAL TECHNOLOGY VACANCY SENSOR WITH AMBIENT LIGHT DETECTION. METAL CLAD (CABLE) LUTRON MAESTRO #MS -A102 -V -WH ALUMINUM "OS" WALLBOX DUAL TECHNOLOGY OCCUPANCY SENSOR WITH AMBIENT LIGHT DETECTION. MAIN CIRCUIT BREAKER LUTRON MAESTRO #MS -A102 -WH AMERICAN NATIONAL STANDARDS INSTITUTE "D" TWO BUTTON WALL SWITCH WITH RAISE/LOWER (BRIGHTEN/DIM) CONTROL. MOLDED CASE CIRCUIT BREAKER LUTRON SEETOUCH QS #QSW52-2BRLI-WH OS CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. MOTOR CONTROL CENTER LUTRON #LOS -CDT -2000 -WH WITH POWER PACK #PP -DV AUTOMATIC TRANSFER SWITCH CEILING MOUNTED WIRELESS DAYLIGHT SENSOR. DS LUTRON RADIO POWR SAVR #LRF2-DCRB-WH ABBREVIATIONS A, AMP AMPERES KVA KILOVOLT AMPERES AC ABOVE COUNTER KV KILOVOLT ADA AMERICANS WITH DISABILITIES ACT KW KILOWATTS AFF ABOVE FINISH FLOOR LED LIGHT EMITTING DIODE AFG ABOVE FINISH GRADE LTG LIGHTING AHJ AUTHORITY HAVING JURISDICTION LFMC LIQUID TIGHT FLEXIBLE METAL CONDUIT AHU AIR HANDLING UNIT MAU MAKE-UP AIR UNIT AIC AMPERE INTERRUPTING CAPACITY MC METAL CLAD (CABLE) AL ALUMINUM MCB MAIN CIRCUIT BREAKER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MCCB MOLDED CASE CIRCUIT BREAKER ATO AUTOMATIC THROW OVER SWITCH MCC MOTOR CONTROL CENTER ATS AUTOMATIC TRANSFER SWITCH MCP MOTOR CIRCUIT PROTECTOR ATC AUTOMATIC TEMPERATURE CONTROL MISC MISCELLANEOUS AWG AMERICAN WIRE GAUGE MLO MAIN LUGS ONLY BAS BUILDING AUTOMATION SYSTEM NEC NATIONAL ELECTRIC CODE BFG BELOW FINISH GRADE NEMA NATIONAL ELECTRICAL MANUFACTURES BMS BUILDING MANAGEMENT SYSTEM ASSOCIATION C CONDUIT NFPA NATIONAL FIRE PROTECTION ASSOCIATION CAT CATALOG NIC NOT IN CONTRACT CUH CABINET UNIT HEATER N.C. NORMALLY CLOSED CB CIRCUIT BREAKER NMSC NON-METALLIC SHEATHED CABLE CBM CERTIFIED BALLASTS MANUFACTURERS N.O. NORMALLY OPEN CKT CIRCUIT NTS NOT TO SCALE CL CENTERLINE P POLE CLF CURRENT LIMITING FUSE PB PUSH-BUTTON COL COLUMN PNL PANEL CPT CONTROL POWER TRANSFORMER POS POINT OF SALES CT CURRENT TRANSFORMER PT POTENTIAL TRANSFORMER CU COPPER PVC POLYVINYL CHLORIDE EF EXHAUST FAN RMC RIGID METAL CONDUIT EM EMERGENCY RMS ROOT MEAN SQUARED EMT ELECTRICAL METALLIC TUBING RNMC RIGID NONMETALLIC CONDUIT EPO EMERGENCY POWER OFF RTU ROOF TOP UNIT ETR EXISTING TO REMAIN SCH SCHEDULE EWC ELECTRIC WATER COOLER SP SPARE F FUSE SWD SWITCH DUTY (RATED) FCU FAN COIL UNIT SYM SYMMETRICAL FLA FULL LOAD AMPERES TGB TELEPHONE GROUNGING BAR FMC FLEXIBLE METAL CONDUIT TMCB THERMAL MAGNETIC CIRCUIT BREAKER FNMC FLEXIBLE NON-METALLIC CONDUIT TMGB TELEPHONE MAIN GROUNDING BAR FT FEET U/G UNDERGROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER UH UNIT HEATER GND, G GROUND OR GROUNDING UL UNDERWRITERS LABORATORIES GRMC GALVANIZED RIGID METALLIC CONDUIT UNO UNLESS NOTED OTHERWISE HACR HEATING, AIR CONDITIONING, REFRIGERATION V VOLT HID HIGH INTENSITY DISCHARGE W WIRE HOA HAND, OFF, AUTOMATIC SWITCH WH WATER HEATER IEEE INSTITUTE OF ELECTRICAL & ELECTRONIC WP WEATHER PROOF ENGINEERS XFMR TRANSFORMER IMC INTERMEDIATE METAL CONDUIT A DELTA IN INCHES WYE INT INTERLOCK 0 PHASE K KILO/THOUSAND KCMIL THOUSAND CIRCULAR MILS CIRCUITING AND RACEWAY LEGEND SYMBOL DESCRIPTION H,�G HP2/7 HOME RUN TO PANEL "HP2", CIRCUIT #7 VIA A 20A/1 P CIRCUIT BREAKER WITH NN 2#12AWG, #12(G), 3/4"CONDUIT UNLESS NOTED OTHERWISE. HASH MARKS INDICATE S❑X CONDUCTOR QUANITY AND TYPES. - - - - - UNDER FLOOR OR IN -SLAB CIRCUITING OR RACEWAY 0 CIRCUITRY TURNING UP POWER DISTRIBUTION EQUIPMENT SYMBOL LEGEND SYMBOL DESCRIPTION G 48OV277 VOLT, 30, 4 WIRE BRANCH CIRCUIT PANELBOARD 208Y/120 VOLT, 30, 4 WIRE BRANCH CIRCUIT PANELBOARD FIRM ALARM SYMBOL LEGEND ❑F MANUAL PULL STATION E4 COMBINATION AUDIBLE/VISUAL (HORN/STROBE) SIGNALING DEVICE Q VISUAL (STROBE) ONLY SIGNALING DEVICE S❑X SMOKE DETECTOR - "X" INDICATES THE FOLLOWING: "E" DENOTES SMOKE DETECTOR WITH AUXILIARY CONTACTS FOR ELEVATOR RECALL. DEMOLITION ANNOTATION LEGEND "X" DENOTES EXISTING DEVICE/EQUIPMENT TO BE REMOVED IN ITS ENTIRETY INCLUDING JUNCTION M E B BOXES, CONDUITS AND CIRCUITRY, ETC. COMPLETE, BACK TO SOURCE OR NEXT ACTIVE DEVICE L Y BEING MAINTAINED ON CIRCUIT. "XR" DENOTES EXISTING DEVICE/EQUIPMENT TO BE RELOCATED IN ITS ENTIRETY. MAINTAIN ALL BRANCH CIRCUIT WIRING, CONDUIT, ETC. FOR RELOCATION TO NEW LOCATION ("XN") AS IS= INDICATED ON "NEW WORK" DRAWINGS. "XN" DENOTES NEW LOCATION OF EXISTING RELOCATED ("XR") DEVICE/EQUIPMENT. REWORK ALL BRANCH CIRCUIT WIRING, CONDUIT, ETC. TO NEW LOCATION AS REQUIRED. "XM" DENOTES EXISTING DEVICE/EQUIPMENT TO BE MAINTAINED. • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc ,,,, I1111/1,,,,, S TTFR No. 11400468 = •� '• =-o'STATE OF GENERAL ELECTRICAL NOTES 1. ALL "BUILDING STANDARDS" AND/OR "BUILDING SPECIFICATIONS" SHALL BE CONSIDERED AN INTEGRAL PART OF THESE DOCUMENTS AND THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN A COPY OF THESE DOCUMENTS AND COMPLY WITH ALL REQUIREMENTS, STANDARDS, AND SPECIFICATIONS CONTAINED WITHIN. 2. THESE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ARE INTENDED TO CONVEY THE SCOPE OF WORK AND INDICATE GENERAL ARRANGEMENT OF LIGHTING FIXTURES, DEVICES, CONTROLS, ELECTRICAL FIXTURES, MOTORS, PANELBOARDS, EQUIPMENT, ETC. THE LOCATIONS OF ALL ITEMS SHOWN ON THESE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED AT THE PROJECT. ALL LOCATIONS OF WORK EXPOSED TO VIEW ARE SUBJECT TO APPROVAL OF THE ARCHITECT PRIOR TO ROUGH -INS. 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT ALL NEW WORK WILL FIT INTO THE EXISTING STRUCTURE AND CONDITIONS IN THE MANNER INTENDED AND AS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/OWNERS REPRESENTATIVE PRIOR TO ANY ROUGH -INS, FABRICATIONS, OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A RFI, INCLUDING A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. 4. ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE PROMPTLY BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION DURING THE BIDDING PERIOD. NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF HIS FAILURE TO HAVE BROUGHT SAID DISCREPANCIES TO THE ATTENTION OF THE ENGINEER DURING THE BIDDING PERIOD OR OF ANY ERROR ON THE CONTRACTOR'S PART. 5. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT, PROFESSIONAL AND WORKMANLIKE MANNER, RECTILINEAR TO FINISHES AND BUILDING STRUCTURE. 6. ALL COMPONENTS SHOWN ON THE RISER/ONE-LINE DIAGRAMS, BUT NOT ON THE PLAN OR VICE VERSA, SHALL BE INCLUDED AS IF SHOWN ON BOTH. 7. REFER TO ARCHITECTURAL ELEVATIONS TO DERIVE EXACT LOCATIONS OF ALL RECEPTACLES, OUTLETS/JACKS, SWITCHES, WALL AND PENDANT/CABLE MOUNTED LUMINAIRES, ETC. LUMINAIRES AND CEILING MOUNTED EQUIPMENT SHALL BE COORDINATED WITH THE ARCHITECTURAL RCP (REFLECTED CEILING PLANS). 8. ALL CIRCUITING SHALL BE RUN CONCEALED UNLESS SPECIFIED OTHERWISE. 9. ALL RACEWAYS RUNNING THROUGH BUILDING EXPANSION JOINTS SHALL BE EQUIPPED WITH APPROPRIATE EXPANSION FITTINGS. 10. CONDUIT HOME RUNS SHOWN ON THE DRAWING WITH MORE THAN (3) CURRENT CARRYING CONDUCTORS ARE SHOWN DIAGRAMATICALLY. THIS CONTRACTOR SHALL NOT INSTALL MORE THAN (3) CURRENT CARRYING CONDUCTORS IN A RACEWAY UNLESS NATIONAL ELECTRIC CODE (N.E.C), ARTICLE 310.15 DERATING FACTORS ARE APPLIED. 11. ALL LIGHTING AND GENERAL POWER BRANCH CIRCUITS SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR, UNLESS SPECIFICALLY INDICATED OTHERWISE. 12. THE ELECTRICAL CONTRACTOR SHALL REFER TO THE ELECTRICAL SPECIFICATIONS FOR ACCEPTABLE CONDUIT TYPES/LOCATIONS. ALL CONDUIT SIZES ON THE DRAWINGS ARE BASED ON THE CURRENT ADOPTED EDITION OF THE N.E.C. CONDUIT FILL TABLES FOR ELECTRICAL METALLIC TUBING E.M.T . CONDUIT SIZES SHALL BE REVISED TO THE SIZE REQUIRED, RELATIVE TO THE ACTUAL CONDUIT TYPE TO BE INSTALLED. 13. IT IS NOT INTENDED THAT THE PLANS INDICATE ALL OBSTRUCTIONS, NECESSARY BENDS, OFFSETS, AND PULL BOXES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL HIS WORK TO CONFORM TO N.E.C. REQUIREMENTS, THE STRUCTURE, MAINTAIN HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR. REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AS REQUIRED. 14. IT IS NOT INTENDED THAT THE PLANS INDICATE ALL CONDUIT ROUTES, PULL BOXES, JUNCTION BOXES, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING ACTUAL CONDUIT ROUTING, QUANTITY AND LOCATION OF PULL BOXES WITHIN ACCESSIBLE LOCATIONS. 15. PROVIDE SCREW -COVER PULL BOXES IN CONDUIT RUNS AS REQUIRED TO LIMIT THE NUMBER OF BENDS TO NO MORE THAN FOUR (4) 90° OR 360 DEGREES TOTAL. SIZE PULL BOXES IN ACCORDANCE WITH NEC, ARTICLE 314.28, DOCUMENT ON RECORD DRAWINGS, SIZE AND LOCATION OF PULL BOXES USED IN FEEDER CONDUIT RUNS. 16. WHERE MULTIPLE DEVICES OF THE SAME TYPE/STYLE ARE SHOWN NEXT TO EACH OTHER, GANG TOGETHER IN A SINGLE COVER PLATE. 17. ALL FLUSH MOUNTED PANELBOARDS SHALL HAVE THREE (3), 3/4" CONDUITS STUBBED ABOVE ACCESSABLE CEILINGS FOR FUTURE CIRCUITS. 18. FIELD VERIFY THE EXACT LOCATION OF MECHANICAL HVAC AND PLUMBING EQUIPMENT THAT REQUIRE ELECTRICAL CONNECTIONS WITH RESPECTIVE CONTRACTORS. a TYPICAL DEVICE MOUNTING FIRE ALARM AUDIBLE/VISUAL AND VISUAL ONLY SIGNALING DEVICES RECEPTACLES BEHIND 0 REFRIGERATORS AND ® VENDING MACHINES WALL TELEPHONES FIRE ALARM MANUAL PULL STATION LIGHTING CONTROLS (CONFIRM MOUNTING HEIGHT a WITH LOCAL CODE REQUIREMENTS) VOLUME CONTROLS M: DEVICES ABOVE COUNTERTOP AND/OR BACKSPLASH aa a M RECEPTACLES IN MECH/ELEC SPACES AND ADJACENT TO LAVATORIES o o ® a M: RECEPTACLES BEHIND �a DOMESTIC WASHERS AND DRYERS GENERAL PURPOSE 00 RECEPTACLES VOICE/DATA OUTLETS ap 6] O RECEPTACLES SERVING DISHWASHER AND °O GARBAGE DISPOSAL I FINISHED FLOOR a NOTES: 1. ALL MOUNTING HEIGHTS SHALL BE MEASURED FROM FINISHED FLOOR TO THE CENTERLINE OF DEVICE EXCEPT FIRE ALARM STROBE LIGHT. 2. NO WIRING DEVICE OUTLET BOXES SHALL BE MOUNTED BACK TO BACK. 3. ALL MOUNTING DEVICES SHALL BE INSTALLED AT MOUNTING HEIGHTS AS INDICATED ON THIS DETAIL UNLESS OTHERWISE NOTED. 4. FOR ALL ELEVATIONS (WHERE APPLICABLE), CASEWORK DETAILS, FIRE WALLS, SMOKE WALLS, LOCATION OF COUNTERTOP RECEPTACLES, LIGHTING FIXTURE SWITCHES, TELEPHONE OUTLETS, EQUIPMENT ROUGH -INS, HEADWALLS, ETC., SEE ARCHITECTURAL DRAWINGS. WHERE NO ARCHITECTURAL ELEVATIONS OR DETAILS OCCUR, THE ELECTRICAL CONTRACTOR SHALL USE PRACTICAL MEANS AND METHODS AS WELL AS HIS FIELD KNOWLEDGE TO LOCATE DEVICES IN THE BEST SUITED AND MOST PRACTICAL LOCATIONS FOR THE DEVICE. H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Electrical Schedules, Legends and Notes No. E-0.04 Drawn by: M E B Checked by: A,JM Approved by: A,JM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: Drawing: Electrical Schedules, Legends and Notes No. E-0.04 CD CD `CD O1 TYPICAL XM CD `CD XM XM II II �C II II II II II CD CD CD CD II II II IrllTr� II �IIIf� XR / 111111 \ / II II \ XM CD CD CD `CD CD CD EXISTING PANEL "CR" EXISTING PANEL "CR -A" � iii ` CD CD I I FO II II II II II I�C3 II II II II II CII -9 T- I I CD CD CD CD CDS CD` CD` CD 0 TYPICAL 9_ XR CDC CDC CD` CD`, e GENERAL DEMOLITION NOTES: 1. THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE TO BE USED AS A GUIDELINE ONLY FOR THE SCOPE OF DEMOLITION WORK. THE CONTRACTOR SHALL VISIT THE PROJECT SITE DURING THE BID PHASE TO VERIFY THE EXACT CONDITIONS AND SCOPE OF WORK REQUIRED FOR A COMPLETE AND INCLUSIVE DEMOLITION PACKAGE. 2. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE CONTRACT DOCUMENTS AND TO HAVE SATISFIED HIMSELF AS TO THE CONDITIONS OF THE PREMISES, THE SITE, ANY OBSTRUCTIONS, THE ACTUAL LEVELS, ACCESS PANELS, AND ALL OTHER EXISTING CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD, SHALL CHECK LOCATION OF AND CONNECTION TO EXISTING FACILITIES, AND SHALL ASSUME ALL RESPONSIBILITY FOR SAME. 3. THE CONTRACTOR SHALL COORDINATE WITH THE TENANT AND/OR BUILDING MANAGEMENT ALL INTERRUPTION OF ELECTRICAL SERVICES WITHIN THE TENANT SPACE AND/OR BUILDING. 4. ALL EXISTING LUMINAIRES AND ASSOCIATED CONTROLS, ELECTRICAL EQUIPMENT, WIRING DEVICES, FIRE ALARM DEVICES, ETC. NOT INDICATED ON THIS PLAN SHALL BE EXISTING TO REMAIN, UNLESS SPECIFICALLY NOTED OTHERWISE. 5. FOR ALL RENOVATION/REMOLDING WORK, INCLUDING ALL AREAS OF NO OR MINIMAL WORK, EXISTING ELECTRICAL SERVICES SHALL BE MAINTAINED TO LUMINAIRES, EQUIPMENT, WIRING DEVICES, ETC. (POWER, LIGHTING, ETC.), THAT ARE REQUIRED TO BE MAINTAINED. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THESE SERVICES, EQUIPMENT, WIRING DEVICES THAT ARE EXISTING TO REMAIN, WHETHER OR NOT INDICATED ON THE PLANS. 6. DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, WIRING DEVICES, TELECOM DEVICES, BLANK COVER PLATES, ETC. LOCATED IN WALLS/PARTITIONS LABELED AS "TO BE REMOVED". REMOVE ALL EXISTING BRANCH CIRCUITING (CONDUCTORS AND CONDUIT) BACK TO LAST ACTIVE DEVICE (OR SOURCE IF NO ACTIVE DEVICES REMAIN). 7. ALL ELECTRICAL LUMINAIRES, EQUIPMENT, WIRING DEVICES, TELECOMMUNICATIONS VOICE/DATA CABLING, ETC. SHALL BE REMOVED COMPLETE, BACK TO SOURCE, (PANELBOARD, TERMINAL BOARDS, ETC.), INCLUDING ALL BRANCH CIRCUITING, (CONDUCTORS AND CONDUIT), FEEDERS, SUPPORTS, JUNCTION BOXES, PULL BOXES, ETC. 8. MAINTAIN OR PROVIDE TEMPORARY ELECTRICAL SERVICES, SUCH AS LIGHTING AND POWER IN ALL AREAS OF DEMOLITION AND SURROUNDING AREAS NOT IN DEMOLITION. 9. THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL, MECHANICAL HVAC, AND PLUMBING DEMOLITION DRAWINGS FOR ALL EQUIPMENT BEING DEMOLISHED, AND SHALL DISCONNECT AND REMOVE COMPLETE THE ELECTRICAL SERVICES TO ALL EQUIPMENT AND WIRING DEVICES. 10. EQUIPMENT AND WIRING DEVICES INDICATED AS "XR", (EXISTING TO BE RELOCATED), SHALL BE STORED FOR RE -USE AS INDICATED "W', (NEW LOCATION OF EXISTING RELOCATED DEVICE), ON NEW PLAN DRAWINGS. DEVICES SHALL BE CLEANED, LUMINAIRES RE-LAMPED PER SPECIFICATIONS, AND BALLAST REPLACED WHERE FOUND TO BE INOPERABLE. 11. EXISTING FIRE ALARM DEVICES THAT ARE "XM", (EXISTING TO REMAIN), SHALL BE PROTECTED FROM CONSTRUCTION DAMAGE AND DIRT. THE FIRE ALARM SYSTEM SHALL BE KEPT OPERABLE DURING CONSTRUCTION. 12. ANY CIRCUITS FEEDING THROUGH EQUIPMENT OR DEVICES THAT ARE BEING DEMOLISHED, REWORKED, OR RELOCATED, AND FEEDING OTHER EQUIPMENT/DEVICES THAT REMAIN ARE TO BE MAINTAINED. 13. ALL CUTTING AND PATCHING OF WALLS, CEILINGS, OR FLOORS THAT ARE DISTURBED BY DEMOLITION SHALL BE RETURNED TO THEIR ORIGINAL CONDITION. REFER TO THE ARCHITECTURAL DOCUMENTS FOR EXACT SPECIFICATION REQUIREMENTS. PATCH FLOOR TO ORIGINAL CONSTRUCTION SPECIFICATIONS AND U.L. FIRE RATING LISTINGS FOR ALL FLOOR MOUNTED DEVICES SUCH AS FLOOR BOXES, (FIRE RATED) POKE-THROUGHS, ETC. WHICH HAVE BEEN REMOVED. 14. ALL EQUIPMENT AND/OR DEVICES THAT ARE REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO THE TENANT AND/OR BUILDING MANAGEMENT OR DISPOSED OF PER THEIR DIRECTION. 15. ALL MATERIAL TO BE DISPOSED SHALL BE DONE UNDER STRICT ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL CODE REQUIREMENTS. CD CD CD CD II II I I � II �� (P 6, CD CDC CD (D TYPICAL CD `CD CD�, CDCs • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc XR V c:;rdI XM L Y E R LEW AJM Approved by: / � I I Date: i CD CD `CD O1 TYPICAL XM CD `CD XM XM II II �C II II II II II CD CD CD CD II II II IrllTr� II �IIIf� XR / 111111 \ / II II \ XM CD CD CD `CD CD CD EXISTING PANEL "CR" EXISTING PANEL "CR -A" � iii ` CD CD I I FO II II II II II I�C3 II II II II II CII -9 T- I I CD CD CD CD CDS CD` CD` CD 0 TYPICAL 9_ XR CDC CDC CD` CD`, e GENERAL DEMOLITION NOTES: 1. THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE TO BE USED AS A GUIDELINE ONLY FOR THE SCOPE OF DEMOLITION WORK. THE CONTRACTOR SHALL VISIT THE PROJECT SITE DURING THE BID PHASE TO VERIFY THE EXACT CONDITIONS AND SCOPE OF WORK REQUIRED FOR A COMPLETE AND INCLUSIVE DEMOLITION PACKAGE. 2. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE CONTRACT DOCUMENTS AND TO HAVE SATISFIED HIMSELF AS TO THE CONDITIONS OF THE PREMISES, THE SITE, ANY OBSTRUCTIONS, THE ACTUAL LEVELS, ACCESS PANELS, AND ALL OTHER EXISTING CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD, SHALL CHECK LOCATION OF AND CONNECTION TO EXISTING FACILITIES, AND SHALL ASSUME ALL RESPONSIBILITY FOR SAME. 3. THE CONTRACTOR SHALL COORDINATE WITH THE TENANT AND/OR BUILDING MANAGEMENT ALL INTERRUPTION OF ELECTRICAL SERVICES WITHIN THE TENANT SPACE AND/OR BUILDING. 4. ALL EXISTING LUMINAIRES AND ASSOCIATED CONTROLS, ELECTRICAL EQUIPMENT, WIRING DEVICES, FIRE ALARM DEVICES, ETC. NOT INDICATED ON THIS PLAN SHALL BE EXISTING TO REMAIN, UNLESS SPECIFICALLY NOTED OTHERWISE. 5. FOR ALL RENOVATION/REMOLDING WORK, INCLUDING ALL AREAS OF NO OR MINIMAL WORK, EXISTING ELECTRICAL SERVICES SHALL BE MAINTAINED TO LUMINAIRES, EQUIPMENT, WIRING DEVICES, ETC. (POWER, LIGHTING, ETC.), THAT ARE REQUIRED TO BE MAINTAINED. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THESE SERVICES, EQUIPMENT, WIRING DEVICES THAT ARE EXISTING TO REMAIN, WHETHER OR NOT INDICATED ON THE PLANS. 6. DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, WIRING DEVICES, TELECOM DEVICES, BLANK COVER PLATES, ETC. LOCATED IN WALLS/PARTITIONS LABELED AS "TO BE REMOVED". REMOVE ALL EXISTING BRANCH CIRCUITING (CONDUCTORS AND CONDUIT) BACK TO LAST ACTIVE DEVICE (OR SOURCE IF NO ACTIVE DEVICES REMAIN). 7. ALL ELECTRICAL LUMINAIRES, EQUIPMENT, WIRING DEVICES, TELECOMMUNICATIONS VOICE/DATA CABLING, ETC. SHALL BE REMOVED COMPLETE, BACK TO SOURCE, (PANELBOARD, TERMINAL BOARDS, ETC.), INCLUDING ALL BRANCH CIRCUITING, (CONDUCTORS AND CONDUIT), FEEDERS, SUPPORTS, JUNCTION BOXES, PULL BOXES, ETC. 8. MAINTAIN OR PROVIDE TEMPORARY ELECTRICAL SERVICES, SUCH AS LIGHTING AND POWER IN ALL AREAS OF DEMOLITION AND SURROUNDING AREAS NOT IN DEMOLITION. 9. THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL, MECHANICAL HVAC, AND PLUMBING DEMOLITION DRAWINGS FOR ALL EQUIPMENT BEING DEMOLISHED, AND SHALL DISCONNECT AND REMOVE COMPLETE THE ELECTRICAL SERVICES TO ALL EQUIPMENT AND WIRING DEVICES. 10. EQUIPMENT AND WIRING DEVICES INDICATED AS "XR", (EXISTING TO BE RELOCATED), SHALL BE STORED FOR RE -USE AS INDICATED "W', (NEW LOCATION OF EXISTING RELOCATED DEVICE), ON NEW PLAN DRAWINGS. DEVICES SHALL BE CLEANED, LUMINAIRES RE-LAMPED PER SPECIFICATIONS, AND BALLAST REPLACED WHERE FOUND TO BE INOPERABLE. 11. EXISTING FIRE ALARM DEVICES THAT ARE "XM", (EXISTING TO REMAIN), SHALL BE PROTECTED FROM CONSTRUCTION DAMAGE AND DIRT. THE FIRE ALARM SYSTEM SHALL BE KEPT OPERABLE DURING CONSTRUCTION. 12. ANY CIRCUITS FEEDING THROUGH EQUIPMENT OR DEVICES THAT ARE BEING DEMOLISHED, REWORKED, OR RELOCATED, AND FEEDING OTHER EQUIPMENT/DEVICES THAT REMAIN ARE TO BE MAINTAINED. 13. ALL CUTTING AND PATCHING OF WALLS, CEILINGS, OR FLOORS THAT ARE DISTURBED BY DEMOLITION SHALL BE RETURNED TO THEIR ORIGINAL CONDITION. REFER TO THE ARCHITECTURAL DOCUMENTS FOR EXACT SPECIFICATION REQUIREMENTS. PATCH FLOOR TO ORIGINAL CONSTRUCTION SPECIFICATIONS AND U.L. FIRE RATING LISTINGS FOR ALL FLOOR MOUNTED DEVICES SUCH AS FLOOR BOXES, (FIRE RATED) POKE-THROUGHS, ETC. WHICH HAVE BEEN REMOVED. 14. ALL EQUIPMENT AND/OR DEVICES THAT ARE REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO THE TENANT AND/OR BUILDING MANAGEMENT OR DISPOSED OF PER THEIR DIRECTION. 15. ALL MATERIAL TO BE DISPOSED SHALL BE DONE UNDER STRICT ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL CODE REQUIREMENTS. CD CD CD CD II II I I � II �� (P 6, CD CDC CD (D TYPICAL CD `CD CD�, CDCs • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc XR V E L L Y E R LEW AJM Approved by: / Client Approval: XM Date: �I XR 11 F_ C9 Issue Date: 01 /26/18 F_�___ I 1 I 1 Date Revision —� I I ---- I 1 I I CD CD CD CD CD` CD`, rF � CD` CD`, IXR 54" I I� / 5',� 11 CD, II L CD, CDi CD` II �� II bl II II XM II II EM ffiffiAN XM 4J `STF�'A���'': '4 O No. 11400468 = •� '• ='o'STATE OF Electrical Demolition Power Plan SCALE: ,,$" DEMOLITION PLAN CODED NOTES: XX 0 REMOVE EXISTING 4" CONDUIT SLEEVES AND FIRE RATED POKE -THROUGH DEVICES (iiiiCID) AND PATCH FLOOR TO ORIGINAL SPECIFICATIONS AND FIRE RATING. SEE SRCHITECTURAL SPECIFICATIONS. RELEASED IFCR CONSTRUCTION Subject to aompdiianice with ®III regofatiens of State and ILonal Endes ICltp of Caimal ntro DATE: 02/23/18 Nick Michler N H E L L Y E R LEW AJM Approved by: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual® INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Electrical Demolition Power Plan No. E-1.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Electrical Demolition Power Plan No. E-1.04 GENERAL DEMOLITION NOTES: 1. THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE TO BE USED AS A GUIDELINE ONLY FOR THE SCOPE OF DEMOLITION WORK. THE CONTRACTOR SHALL VISIT THE PROJECT SITE DURING THE BID PHASE TO VERIFY THE EXACT CONDITIONS AND SCOPE OF WORK REQUIRED FOR A COMPLETE AND INCLUSIVE DEMOLITION PACKAGE. 2. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE CONTRACT DOCUMENTS AND TO HAVE SATISFIED HIMSELF AS TO THE CONDITIONS OF THE PREMISES, THE SITE, ANY OBSTRUCTIONS, THE ACTUAL LEVELS, ACCESS PANELS, AND ALL OTHER EXISTING CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD, SHALL CHECK LOCATION OF AND CONNECTION TO EXISTING FACILITIES, AND SHALL ASSUME ALL RESPONSIBILITY FOR SAME. 3. THE CONTRACTOR SHALL COORDINATE WITH THE TENANT AND/OR BUILDING MANAGEMENT ALL INTERRUPTION OF ELECTRICAL SERVICES WITHIN THE TENANT SPACE AND/OR BUILDING. 4. ALL EXISTING LUMINAIRES AND ASSOCIATED CONTROLS, ELECTRICAL EQUIPMENT, WIRING DEVICES, FIRE ALARM DEVICES, ETC. NOT INDICATED ON THIS PLAN SHALL BE EXISTING TO REMAIN, UNLESS SPECIFICALLY NOTED OTHERWISE. 5. FOR ALL RENOVATION/REMOLDING WORK, INCLUDING ALL AREAS OF NO OR MINIMAL WORK, EXISTING ELECTRICAL SERVICES SHALL BE MAINTAINED TO LUMINAIRES, EQUIPMENT, WIRING DEVICES, ETC. (POWER, LIGHTING, ETC.), THAT ARE REQUIRED TO BE MAINTAINED. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THESE SERVICES, EQUIPMENT, WIRING DEVICES THAT ARE EXISTING TO REMAIN, WHETHER OR NOT INDICATED ON THE PLANS. 6. DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, WIRING DEVICES, TELECOM DEVICES, BLANK COVER PLATES, ETC. LOCATED IN WALLS/PARTITIONS LABELED AS "TO BE REMOVED". REMOVE ALL EXISTING BRANCH CIRCUITING (CONDUCTORS AND CONDUIT) BACK TO LAST ACTIVE DEVICE (OR SOURCE IF NO ACTIVE DEVICES REMAIN). 7. ALL ELECTRICAL LUMINAIRES, EQUIPMENT, WIRING DEVICES, TELECOMMUNICATIONS VOICE/DATA CABLING, ETC. SHALL BE REMOVED COMPLETE, BACK TO SOURCE, (PANELBOARD, TERMINAL BOARDS, ETC.), INCLUDING ALL BRANCH CIRCUITING, (CONDUCTORS AND CONDUIT), FEEDERS, SUPPORTS, JUNCTION BOXES, PULL BOXES, ETC. 8. MAINTAIN OR PROVIDE TEMPORARY ELECTRICAL SERVICES, SUCH AS LIGHTING AND POWER IN ALL AREAS OF DEMOLITION AND SURROUNDING AREAS NOT IN DEMOLITION. 9. THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL, MECHANICAL HVAC, AND PLUMBING DEMOLITION DRAWINGS FOR ALL EQUIPMENT BEING DEMOLISHED, AND SHALL DISCONNECT AND REMOVE COMPLETE THE ELECTRICAL SERVICES TO ALL EQUIPMENT AND WIRING DEVICES. 10. EQUIPMENT AND WIRING DEVICES INDICATED AS "XR", (EXISTING TO BE RELOCATED), SHALL BE STORED FOR RE -USE AS INDICATED "W', (NEW LOCATION OF EXISTING RELOCATED DEVICE), ON NEW PLAN DRAWINGS. DEVICES SHALL BE CLEANED, LUMINAIRES RE-LAMPED PER SPECIFICATIONS, AND BALLAST REPLACED WHERE FOUND TO BE INOPERABLE. 11. EXISTING FIRE ALARM DEVICES THAT ARE "XM", (EXISTING TO REMAIN), SHALL BE PROTECTED FROM CONSTRUCTION DAMAGE AND DIRT. THE FIRE ALARM SYSTEM SHALL BE KEPT OPERABLE DURING CONSTRUCTION. 12. ANY CIRCUITS FEEDING THROUGH EQUIPMENT OR DEVICES THAT ARE BEING DEMOLISHED, REWORKED, OR RELOCATED, AND FEEDING OTHER EQUIPMENT/DEVICES THAT REMAIN ARE TO BE MAINTAINED. 13. ALL CUTTING AND PATCHING OF WALLS, CEILINGS, OR FLOORS THAT ARE DISTURBED BY DEMOLITION SHALL BE RETURNED TO THEIR ORIGINAL CONDITION. REFER TO THE ARCHITECTURAL DOCUMENTS FOR EXACT SPECIFICATION REQUIREMENTS. PATCH FLOOR TO ORIGINAL CONSTRUCTION SPECIFICATIONS AND U.L. FIRE RATING LISTINGS FOR ALL FLOOR MOUNTED DEVICES SUCH AS FLOOR BOXES, (FIRE RATED) POKE-THROUGHS, ETC. WHICH HAVE BEEN REMOVED. 14. ALL EQUIPMENT AND/OR DEVICES THAT ARE REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO THE TENANT AND/OR BUILDING MANAGEMENT OR DISPOSED OF PER THEIR DIRECTION. 15. ALL MATERIAL TO BE DISPOSED SHALL BE DONE UNDER STRICT ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL CODE REQUIREMENTS. NO XV • Integrated Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc S TTFR No. 11400468 = •� • - ='o'STATE OF B B0 B/ B0 R0 Electrical Demolition Lighting Plan SCALE: 1/8": RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes Eltp at Eaimal ntro DATE: 02/23/18 N H E L L Y E R LEW IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: W m Liberty Mutual® INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawn by: M E B Checked by: AN Approved by: AN Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Electrical Demolition Lighting Plan No. E-2.04 GENERAL POWER PLAN NOTES: 1. EXACT LOCATION OF MECHANICAL, PLUMBING, KITCHEN, FURNITURE SYSTEMS, OWNER FURNISHED EQUIPMENT, ETC. THAT REQUIRE ELECTRICAL CONNECTIONS ARE SHOWN ON THE MECHANICAL, PLUMBING, AND/OR ARCHITECTURAL DRAWINGS. COORDINATE EXACT LOCATIONS WITH RESPECTIVE CONTRACTORS AND/OR VENDORS PRIOR TO ANY ROUGH -INS. 2. REVIEW AND COORDINATE WITH ALL TRADES' CONTRACT DOCUMENTS TO DETERMINE SPECIFIC MOUNTING LOCATIONS FOR EQUIPMENT WITH ELECTRICAL CONNECTIONS. COORDINATE EXACT MOUNTING LOCATIONS WITH THE SPECIFIC TRADE AND ARCHITECT. 3. MINIMUM CONDUCTOR SIZE FOR 277 VOLT BRANCH CIRCUITS SHALL BE 12 -AWG. FOR 277 VOLT BRANCH CIRCUITS WITH HOMERUNS OVER 150 LINEAR FEET A MINIMUM WIRE SIZE OF 10 -AWG SHALL BE PROVIDED FROM FIRST JUNCTION/OUTLET BOX TO BRANCH CIRCUIT PANELBOARD. 4. MINIMUM CONDUCTOR SIZE FOR 120 VOLT BRANCH CIRCUITS SHALL BE 12 -AWG. FOR 120 VOLT BRANCH CIRCUITS WITH HOMERUNS OVER 100 LINEAR FEET, A MINIMUM WIRE SIZE OF 10 -AWG SHALL BE PROVIDED FROM FIRST JUNCTION/OUTLET BOX TO BRANCH CIRCUIT PANELBOARD. FOR 120 VOLT BRANCH CIRCUITS WITH HOMERUNS OVER 150 LINEAR FEET, A MINIMUM WIRE SIZE OF 8 -AWG SHALL BE PROVIDED FROM FIRST JUNCTION/OUTLET BOX TO BRANCH CIRCUIT PANELBOARD. 5. ALL WIRING SHALL BE IDENTIFIED BY PANELBOARD AND CIRCUIT NUMBER(S) IN ALL CABINETS, JUNCTION BOXES, WIRING TROUGHS, ENCLOSURES, SPLICE OR TERMINATION POINTS, ETC. 6. A NEW TYPED PANELBOARD DIRECTORY CARD SHALL BE PROVIDED FOR ALL PANELS INSTALLED OR MODIFIED UNDER THIS CONTRACT. NEW DIRECTORY CARDS SHALL BE LOCATED ON THE INSIDE DOOR OF ASSOCIATED PANELS. 7. FINALIZE ALL SECURITY DEVICE LOCATIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH -IN. 8. PER N.E.C. ARTICLE 620, ELEVATOR PIT AND MACHINE ROOM LIGHTING SHALL NOT BE CONNECTED TO THE LOAD SIDE OF GFCI TYPE RECEPTACLE(S). EXISTING BUILDING FIRE ALARM SYSTEM NOTES: 1. PRIOR TO BID SUBMITTAL, THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE WITH BUILDING MANAGEMENT AND THE BUILDING APPROVED FIRE ALARM SYSTEM VENDOR TO VERIFY THE EXISTING SYSTEM, OPERATIONS, COMPONENTS, PANEL LOCATIONS, CABLING, ROUTING REQUIREMENTS, ETC. 2. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH BUILDING MANAGEMENT AND THE FIRE ALARM SYSTEM VENDOR FOR ALL NEW COMPONENTS AND/OR SYSTEM MODIFICATIONS AS REQUIRED TO ACCOMMODATE RE -USE OF EXISTING AND/OR NEW FIRE ALARM DEVICES) AND CODE COMPLIANCE OPERATION. 3. FIRE ALARM DEVICE LOCATIONS ARE DIAGRAMMATIC ONLY. THE FIRE ALARM SYSTEM VENDOR SHALL BE RESPONSIBLE TO VERIFY ALL NEW AND/OR EXISTING DEVICE SPECIFICATIONS AND CHARACTERISTICS BASED ON EACH SYSTEM DEVICE SPECIFICATIONS. PROVIDE FINAL DEVICE COUNTS AND LAYOUT DRAWINGS OF DEVICE LOCATIONS TO MEET ALL STATE AND LOCAL FIRE ALARM CODE REQUIREMENTS. 4. PROVIDE ALL NEW EQUIPMENT AND DEVICES AS REQUIRED FOR A COMPLETE AND CODE COMPLIANT SYSTEM. THE ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM VENDOR SHALL BE RESPONSIBLE TO PROVIDE ALL SERVICES REQUIRED TO PROVIDE A "COMPLETE AND OPERATIONAL SYSTEM" PER ALL LOCAL MUNICIPALITY AND STATE CODE REQUIREMENTS. THIS INCLUDES BUT IS NOT LIMITED TO: PRODUCING FIRE ALARM PLAN DRAWINGS AND SPECIFICATIONS FOR PERMITTING, SHOP DRAWINGS, AND INSTALLATION. ALL DOCUMENTS MUST INCLUDE ALL SIGNALING CIRCUIT LOADS, VOLTAGE DROPS, WIRING DIAGRAMS WIRE SIZE, BATTERY CALCULATIONS, ETC. PER MUNICIPAL CODE OF THE CITY OF INDIANAPOLIS, AND STATE OF INDIANA CODE REQUIREMENTS. K K TO RACK (#6 AWG) TO RACK (#6 AWG) TO RACK (#6 AWG) TO BUILDING "TMGB" IN MAIN TELEPHONE CLOSET (#6 AWG) Oil 1110 NEMA COPPER LUGS. SIZED PER CONDUCTOR SIZE INDICATED ON DRAWINGS. (TYPICAL) GROUND BAR ASSEMBLY - 1/4"x 2"x 12" NEMA BAR CHATSWORTH #13622-012 COMPLETE WITH INSULATORS AND MOUNTING BRACKETS. ALONG "TTB" IN TELECOM ROOM GROUND BAR DETAIL "TGB" SCALE: NOT TO SCALE NOTES: 1. VERIFY EXACT MOUNTING LOCATION OF TGB WITH IT DEPARTMENT PRIOR TO ANY ROUGH -IN. TO EXISTING POWER AS REQUIRED 3/4"C TO ACCESS FACR 3/4"C TO FACP (FIRE ALARM CONTROL PANEL) CONTROL PANEL JB I:y9l1111111110 CARD READER/ELECTRIC STRIKE DETAIL CR FLUSH MOUNTED BACK BOX ON SECURE SIDE OF DOOR FOR CARD READER. MOUNT PER ADA REQUIREMENTS. TO JB FACR FIRE ALARM CONTROL RELAY FOR DOOR RELEASE. JBJUNCTION BOX 8" X 10" W/COVER, ON SECURE SIDE OF SPACE 6" ABOVE ACCESSIBLE CEILING. DB ES I ELECTRIC STRIKE CONCEALED WITHIN DOOR FRAME. CR ES O MD MOTION DETECTOR pB "REQUEST TO EXIT" PUSHBUTTON - FLUSH MOUNTED ON NON -SECURE SIDE OF DOOR, MOUNTED PER ADA REQUIREMENTS. • Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc No.11400468 - •; • - SCALE: Electrical Power Plan ,/ SS ALE: PANEL "CR" 208Y/120V-3�-0 Enlarged Telecom Room 403 Power Plan SCALE: 1/4" = 1'-0" 1 2J RELEASED IFOR CONSTRICTION Subject to aompdiianice with ®III regofatiens of State and (Feel Endes ICltp of Caimal ntro DATE: 02/23/18 14a11010.1t41IN COFFEE MAKER LIH-1 30-277V-1� P4/41 P4/39 i 5 MICROWAVES(2) I REFRIGERATOR Enlarged HIVE 414A Power Plan SCALE: 1/4" = 1'-0' 131 ELECTRICAL CODED NOTES: XX O WIRE INTO EXISTING TOILET ROOM RECEPTACLE CIRCUIT. O 4" EMT CONDUIT WITH PULLSTRING AND INSULATING BUSHING AT BOTH ENDS. H 3#10, #10(G), 3/4"1 CR/22,24 L Y E R LEW AJM 30/2 CR/2,4 CR/6,8 FLOOR 60/2 Client Approval: 20/2 20/2 Date: 3#6, #10(G), 3/4" CR/3 CR/10,12 20/2 CR/14,16 SINGLE DOOR SECURITY DETAIL 2O/2 SCALE: NONE CR CR/18,2 20/2 NOTES: Issue For Permit: 01/29/18 � 1. CARD READER PROVIDED BY LIBERTY MUTUAL'S SECURITY VENDOR. ELECTRIC STRIKE :12R/1 Revision PROVIDED BY DOOR HARDWARE VENDOR. P4/37 2. THE ELECTRICAL CONTRACTOR/FIRE ALARM VENDOR IS RESPONSIBLE FOR ALL FIRE ALARM % HARDWIRE: 2 -POLE 60A INPUT BREAKER P4/25 27 P4/ P4/29 P4/35 RELATED WORK TO PROVIDE A COMPLETE OPERATIONAL DOOR PER ALL STATE AND LOCAL TGB HARDWIRE TERMINAL BLOCK 3W+G P4/33 CODE REQUIREMENTS. / (L -L -N -G) TO CHASSIS. L4/18 3. COORDINATE WITH LIBERTY MUTUAL'S SECURITY VENDOR PRIOR TO ANY ROUGH -IN THE EXACT REQUIREMENTS FOR ALL CONDUITS, DEVICE BACK BOX SIZES, LOCATIONS, MOUNTING HEIGHTS, ETC. COORDINATE WITH FIRE ALARM CONTRACTOR AND VENDOR FOR FIRE ALARM INTERFACE POINTS AS REQUIRED. 42" 42" U 14291 42" 4 Enlarged Telecom Room 403 Power Plan SCALE: 1/4" = 1'-0" 1 2J RELEASED IFOR CONSTRICTION Subject to aompdiianice with ®III regofatiens of State and (Feel Endes ICltp of Caimal ntro DATE: 02/23/18 14a11010.1t41IN COFFEE MAKER LIH-1 30-277V-1� P4/41 P4/39 i 5 MICROWAVES(2) I REFRIGERATOR Enlarged HIVE 414A Power Plan SCALE: 1/4" = 1'-0' 131 ELECTRICAL CODED NOTES: XX O WIRE INTO EXISTING TOILET ROOM RECEPTACLE CIRCUIT. O 4" EMT CONDUIT WITH PULLSTRING AND INSULATING BUSHING AT BOTH ENDS. H E L L Y E R LEW AJM Approved by: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. P h i l a. , PA 1 9 1 0 7 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Electrical Power Plan No. E— 3.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Electrical Power Plan No. E— 3.04 DAYLIGHTIN 0 TYPICA GENERAL LIGHTING NOTES: 1. ALL EXIT SIGNS, EMERGENCY LIGHTING BATTERY PACKS, EMERGENCY LUMINAIRES (ON GENERATOR OR EMERGENCY LIGHTING BATTERY PACKS INTEGRAL TO LUMINAIRE), AND NIGHT LIGHTS (DENOTED 'NL') SHALL BE CONNECTED TO THE LOCAL LIGHTING CIRCUIT AHEAD OF ANY CONTROLS SUCH AS: SWITCHES (DEVICE), OCCUPANCY SENSORS AND/OR RELAY CONTROLS. 2. EXACT LOCATION OF ALL LUMINAIRES, AND EXACT MOUNTING HEIGHT OF ALL PENDANT MOUNTED LUMINAIRES SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS PRIOR TO ANY ROUGH—INS. nevi 1^1 irisin H4 • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www. iec-inc.cc 111 A/Iits�rrJpt�w, r !N0 /1400468 Y. r M x � sY STATE OF PO , Itv A� #lilts�y yyY,yy �."9F Electrical Lighting Plan SCALE: RELEASED IFCR CONSTRUCTION Subjeutto uumpdiianmewith alll regulatimna of State and Uncal Endes ICitp at Caimal DATE: 02/23/18 Nick Mishler DAYLIGHTING ZONE #7 N H E M EB L L Y E R L EW Client Approval: IS= ARCHITECTURE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: W- Liberty Mutual© INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Drawing: Electrical Lighting Plan No. E-4.04 Drawn by: M EB Checked by: AJ M Approved by: AJ M Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: 1/8" = 1 '-0" Drawing: Electrical Lighting Plan No. E-4.04 • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc S BFR '�ti Fa •• No.11400468 - •� '• — �•• STATE OF L� 6 Mechanical HVAC Power Plan ,, SCALE: 11 _ RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes ICltp at Caimal ntro DATE: 02/23/18 N H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: WLiberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Mechanical HVAC Power Plan No. E— 5.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Mechanical HVAC Power Plan No. E— 5.04 CKT DESCRIPTION LTG EQPT HVAC XFMR C/B C/B XFMR HVAC EQPT LTG DESCRIPTION LTG CKT 1 CORE LIGHTING 0.36 20/1 A 20/1 HEAT PUMP - SOUTH 0.90 LIGHTING A 20/1 2 3 2 20/1 B 20/1 4 2.25 LIGHTING HEAT PUMP - SOUTH 4 5 B 20/1 20/1 C 20/1 NEMA L6 -20R 2.40 LIGHTING 7 A 6 7 HEAT PUMP - SOUTH 20/1 A 20/1 C 20/1 1.90 LIGHTING 1.50 8 9 20/1 B20 1 HEAT PUMP - SOUTH 1.20 LIGHTING A 25/1 10 11 20/2 20/1 C 20/1 1.44 0.45 LIGHTING HEAT PUMP - SOUTH 12 13 B 25/1 20/1 A 20/1 1.44 0.85 LIGHTING 0.54 14 15 HEAT PUMP - SOUTH 20/1 B 15/1 2.45 3.50 WSHP-46 21 J -BOX TO TERMINAL BLOCK 16 17 B 20/1 C 20/1 3.00 3.50 IH -1 A 25/1 18 19 1 2.50 1 20/1 A 20/1 23 5.00 C 14 15 HEAT PUMP - SOUTHEAST 20 21 B 25/1 20/1 B 20/1 = HEAT PUMP - NORTHWEST ALL CB'S SHALL BE SWD/HID & HACR 22 23 HEAT PUMP - EAST 20/1 C 20/1 C 20/1 3.50 0.54 RATED. PROVIDE THE FOLLOWING WHERE 24 25 SPACE Total kVA -LTG: 18 A HEAT PUMP - EAST 3.50 20/1 A 25/1 26 27 SPACE Total kVA -HVAC: HEAT PUMP B 15/3 = 20 21 HEAT PUMP - SOUTHEAST 28 29 SPACE B 20/1 3.50 C = HEAT PUMP - NORTHWEST "H" = CB CLIP 30 31 SPACE HEAT PUMP - SOUTHEAST 3.50 A C 25/1 4.40 SPACE "A" = ARC FAULT CB 32 33 SPACE 1st 10KVA REC: 24 B HEAT PUMP - TOILET ROOMS 3.50 SPACE A 25/1 34 35 SPACE BALANCE OF REC: HEAT PUMP C = 26 SPACE HEAT PUMP - TOILET ROOMS EAST 36 37 SPACE 1 B 25/1 4.40 A TOTAL kVAD: HEAT PUMP SPACE kVAD A 38 39 SPACE HEAT PUMP - SOUTHEAST 5.30 B C 15/1 2.45 SPACE VOLTAGE: 208Y/12OV, 30, 4W 40 41 NIGHT LIGHT CIRCUIT 0.18 20/1 C WSHP-4-31 2.45 SPACE A 15/1 42 REMARKS: PHASE TOTALS: WSHP-4-32 LOAD SUMMARY: kVAC x D.F. = kVAD 1.47 ALL CB'S SHALL BE SWD/HID & HACR PHASE A. 3.65 0.18 20/1 WSHP-4-34 FURNITURE SYSTEMS 0.90 34 RATED. PROVIDE THE FOLLOWING WHERE PHASE B: 5.90 Total kVA -LTG: 9.95 x 1.25 = 12.44 WSHP-4-36 INDICATED: PHASE C: 5.85 Total kVA -HVAC: 2.45 x 1.00 = 2.45 2.45 "G" = GFCI CB 0.54 15.40 kVAC Total kVA-XFMR: 0.00 x 1.00 = 0.00 1.30 "H" = CB CLIP B 15/1 1.33 Total kVA-EQPT: 3.00 x 1.00 = 3.00 40 "A" = ARC FAULT CB WSW -4-41 2.45 15/1 C 15/1 2.45 D.F. 1.25 1.00 1.00 1.00 0.50 "G" = GFCI CB WSHP-4-42 "S" = SHUNT TRIP CB Total kVA-MISC: 42 REMARKS: ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "G" = GFCI CB "H" = CB CLIP "A" = ARC FAULT CB "S" = SHUNT TRIP CB PHASE TOTALS: PHASE A. PHASE B: PHASE C: 48.40 47.70 43.85 139.95 kVAC LOAD SUMMARY: Total kVA -LTG: Total kVA -HVAC: Total kVA-XFMR: Total kVA-EQPT: kVAC 0.00 139.95 0.00 0.00 x x x x x D.F. 1.25 1.00 1.00 1.00 = = = = = TOTAL kVAD: FEEDER DEMAND: kVAD 0.00 139.95 0.00 0.00 139.95 168.41 kVAD A VOLTAGE: 4BOV277V, 30, 4W AMPS: 225 EXISTING PANEL: H4 TOTAL kVAD: 17.89 kVAD "A" = ARC FAULT CB 1st 10KVA REC: 10.00 x FEEDER DEMAND: 21.53 A VOLTAGE: 480Y/277V, 36, 4W "S" = SHUNT TRIP CB MAIN C/B XX ISOLATED GROUND BAR 6.48 x 0.50 = AMPS: 175 MAIN LUGS ONLY 200% NEUTRAL TOTAL kVAD: 13.24 SURFACE MOUNTED DOUBLE LUGS FEEDER DEMAND: RECESSED MOUNTED A FEED THRU LUGS MAIN C/B XX ISOLATED EXISTING PANEL L4 kAIC SUB FEED C B's AMPS: 400 MAIN LUGS ONLY CKT DESCRIPTION LTG EQPT HVAC XFMR C/B C/B XFMR HVAC EQPT LTG DESCRIPTION 1 QUAD 0.36 CKT 1 HEAT PUMP - SOUTH 3.50 20/1 A 20/1 3.50 3 2 HEAT PUMP - SOUTHWEST 4 2 3 HEAT PUMP - SOUTH 3.50 20/1 B 20/1 3.50 C 20/1 NEMA L6 -20R HEAT PUMP - SOUTHWEST 7 A 4 5 HEAT PUMP - SOUTH 3.50 20/1 C 20/1 20/2 COPIER 1.50 SPARE NEMA L6 -20R 6 7 HEAT PUMP - SOUTH 3.50 20/1 A 25/1 4.40 A 20/2 HEAT PUMP - WEST 1.44 8 9 HEAT PUMP - SOUTH 3.50 1 20/1 B 25/1 4.40 A 20/1 1.44 HEAT PUMP - WEST 0.54 10 11 HEAT PUMP - SOUTH 3.50 20/1 C 20/1 3.50 1 20 21 J -BOX TO TERMINAL BLOCK HEAT PUMP - NORTHWEST B 12 13 HEAT PUMP - SOUTHEAST 3.50 20/1 A 25/1 4.40 19 SIGNAGE 1 2.50 1 HEAT PUMP - NORTHWEST 23 5.00 C 14 15 HEAT PUMP - SOUTHEAST 3.50 20/1 B 25/1 4.40 D.F. = HEAT PUMP - NORTHWEST ALL CB'S SHALL BE SWD/HID & HACR 16 17 HEAT PUMP - EAST 4.40 25/1 C 20/1 3.50 0.54 RATED. PROVIDE THE FOLLOWING WHERE HEAT PUMP - NORTHWEST Total kVA -LTG: 18 19 HEAT PUMP - EAST 3.50 20/1 A 25/1 4.40 12.00 Total kVA -HVAC: HEAT PUMP - NORTHWEST = 20 21 HEAT PUMP - SOUTHEAST 4.40 25/1 B 20/1 3.50 1.00 = HEAT PUMP - NORTHWEST "H" = CB CLIP 22 23 HEAT PUMP - SOUTHEAST 3.50 20/1 C 25/1 4.40 37 SPACE "A" = ARC FAULT CB HEAT PUMP - NORTHWEST 1st 10KVA REC: 24 25 HEAT PUMP - TOILET ROOMS 3.50 20/1 A 25/1 4.40 B 20/1 BALANCE OF REC: HEAT PUMP - NORTH = 26 27 HEAT PUMP - TOILET ROOMS EAST 3.50 20/1 1 B 25/1 4.40 kVAC x 0.00 x 0.00 x 0.00 x 9.72 9.72 x 0.00 x TOTAL kVAD: HEAT PUMP - NORTH kVAD A 28 29 HEAT PUMP - SOUTHEAST 5.30 30/1 C 15/1 2.45 A VOLTAGE: 208Y/12OV, 30, 4W WSHP-4-30 MAIN C/B 0.18 30 31 WSHP-4-31 2.45 15/1 A 15/1 2.45 MAIN LUGS ONLY XXX WSHP-4-32 20/1 B 20/10 0 10.90 32 33 WSHP-4-33 1.47 15/1 B 25/1 5.00 0.18 20/1 WSHP-4-34 FURNITURE SYSTEMS 0.90 34 35 WSHP-4-35 2.45 1 15/1 C 15/1 2.45 LOAD SUMMARY: NEW PANEL: CR WSHP-4-36 kAIC = 36 37 WSHP-4-37 2.45 1 15/1 A 15/1 2.45 0.54 WSHP-4-38 FURNITURE SYSTEMS 38 39 WSHP-4-39 1.30 15/1 B 15/1 1.33 = 0.00 WSHP-4-40 INDICATED: PHASE C: 40 41 WSW -4-41 2.45 15/1 C 15/1 2.45 D.F. 1.25 1.00 1.00 1.00 0.50 "G" = GFCI CB WSHP-4-42 16.48 kVAC Total kVA-MISC: 42 REMARKS: ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "G" = GFCI CB "H" = CB CLIP "A" = ARC FAULT CB "S" = SHUNT TRIP CB PHASE TOTALS: PHASE A. PHASE B: PHASE C: 48.40 47.70 43.85 139.95 kVAC LOAD SUMMARY: Total kVA -LTG: Total kVA -HVAC: Total kVA-XFMR: Total kVA-EQPT: kVAC 0.00 139.95 0.00 0.00 x x x x x D.F. 1.25 1.00 1.00 1.00 = = = = = TOTAL kVAD: FEEDER DEMAND: kVAD 0.00 139.95 0.00 0.00 139.95 168.41 kVAD A VOLTAGE: 4BOV277V, 30, 4W AMPS: 225 EXISTING PANEL: H4 MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC XX ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C B's "A" = ARC FAULT CB 1st 10KVA REC: 10.00 CKT DESCRIPTION LTG REC HVAC MISC. C/B C/B MISC. HVAC REC LTG DESCRIPTION of State and Uncal Endes CKT 1 QUAD 0.36 20/1 A 20/2 1 1.50 20/1 NEMA L6 -20R 3 2 3 QUAD 0.36 20/1 B 1.50 4 5 FOCUS ROOMS FURNITURE SYSTEMS C 20/2 20/1 1.50 C 20/1 NEMA L6 -20R 20/1 6 7 A 1.50 8 9 20/1 A 20/1 B 20/2 COPIER 1.50 8 NEMA L6 -20R 10 11 C 1.50 12 13 20/1 10 A 20/2 20/1 1.50 1.44 NEMA L6 -20R TRAINING ROOM 14 15 B 1.50 16 17 A 20/1 1.44 C 20/2 0.54 1.50 15 NEMA L6 -20R 20/1 18 19 A 11.50 1 20 21 J -BOX TO TERMINAL BLOCK 5.00 60/2 B 30/2 C 20/1 1 1 2.50 1 FURNITURE SYSTEMS NEMA L14 -R 16 22 19 SIGNAGE 1 2.50 1 20/1 24 23 5.00 C 14 1 REMARKS: PHASE TOTALS: 21 LOAD SUMMARY: kVAC x D.F. = kVAD OPEN COLLAB 426 ALL CB'S SHALL BE SWD/HID & HACR PHASE A. 6.36 21 VENDING 20/1 C 20/1 B 20/1 C 20/1 0.54 RATED. PROVIDE THE FOLLOWING WHERE PHASE B: 12.36 Total kVA -LTG: 0.00 x 1.25 = 0.00 20/1 INDICATED: PHASE C: 12.00 Total kVA -HVAC: 0.00 x 1.00 = 0.00 0.18 "G" = GFCI CB GENERATOR RECEPTACLE 30.72 kVAC Total kVA-MISC: 0.00 x 1.00 = 0.00 20/1 "H" = CB CLIP 22 0.54 Total kVA-REC: 30.72 34 C 20/1 36 37 SPACE "A" = ARC FAULT CB C 20/1 A 20/1 1st 10KVA REC: 10.00 x 1.00 = 10.00 39 SPARE 41 "S" = SHUNT TRIP CB 40/2 B 20/1 BALANCE OF REC: 20.72 x 0.50 = 10.36 C 20/1 0.36 TIME WARNER 42 REMARKS: ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "G" = GFCI CB "H" = CB CLIP "A" = ARC FAULT CB "S" = SHUNT TRIP CB PHASE TOTALS: PHASE A: PHASE B: PHASE C: 2.88 4.14 2.70 9.72 kVAC LOAD SUMMARY: Total kVA -LTG: Total kVA -HVAC: Total kVA-MISC: Total kVA-REC: 1 st 1 OKVA REC: BALANCE OF REC: kVAC x 0.00 x 0.00 x 0.00 x 9.72 9.72 x 0.00 x TOTAL kVAD: 20.36 kVAD kVAD A VOLTAGE: 208Y/12OV, 30, 4W AMPS: 250 EXISTING PANEL: P4C 0.18 MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC XX ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C B's FEEDER DEMAND: 56.56 A VOLTAGE: 208Y/12OV, 30, 4W 36 MAIN C/B 0.18 ISOLATED GROUND BAR A 20/1 FURNITURE SYSTEMS 0.90 20/1 AMPS: 100 A 20/1 MAIN LUGS ONLY XXX 200% NEUTRAL 20/1 B 20/10 0 10.90 32 -90 FURNITURE SYSTEMS CONFERENCE 418 SURFACE MOUNTED 40 DOUBLE LUGS 0.18 20/1 C 20/1 FURNITURE SYSTEMS 0.90 34 RECESSED MOUNTED FURNITURE SYSTEMS FEED THRU LUGS REMARKS: PHASE TOTALS: C 2D/1 LOAD SUMMARY: NEW PANEL: CR x kAIC = SUB FEED C B's 37 ALL CB'S SHALL BE SWD/HID & HACR PHASE A: 5.04 CKT DESCRIPTION LTG REC HVAC MISC. C/B C/B MISC. HVAC REC LTG DESCRIPTION of State and Uncal Endes CKT 1 ntro 20/1 A 20/1 0.90 1 OPEN OFFICE 431 20/1 2 3 2 20/1 B 20/1 1.08 B 20/1 FOCUS ROOMS FURNITURE SYSTEMS 4 5 20/1 20/1 C 20/1 0.18 20/1 COPIER 6 7 FIRE ALARM PANEL 20/1 A 20/1 0.18 0.54 COPIER A 8 9 20/1 B 20/1 1.44 9 FURNITURE SYSTEMS TRAINING ROOM 20/1 10 11 0.54 20/1 C 20/1 1.44 11 FURNITURE SYSTEMS TRAINING ROOM 20/1 12 13 20/1 20/1 A 20/1 1.44 12 TRAINING ROOM 0.54 14 15 FURNITURE SYSTEMS 20/1 B 20/1 0.54 C 20/1 MOTHER'S ROOM 15 FURNITURE SYSTEMS 16 17 B 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS MOTHER'S ROOM 16 18 19 SIGNAGE 20/1 20/1 A 20/1 1 0.36 14 BROAD BAND FURNITURE SYSTEMS 20 21 0.18 20/1 B 20/1 1.08 0.54 OPEN COLLAB 426 FURNITURE SYSTEMS 22 23 21 VENDING 20/1 C 20/1 B 20/1 C 20/1 0.54 0.54 24 25 5TH FLOOR COPIER 27 22 20/2 A 20/1 20/1 C 20/1 20/1 0.54 26 B 20/1 28 29 25 REFRIGERATOR 20/1 C 20/1 0.18 FURNITURE SYSTEMS GENERATOR RECEPTACLE 20/1 30 31 33 SPARE 35 26 100/3 A 20/1 20/1 B 20/1 22 0.54 32 B 20/1 34 C 20/1 36 37 SPACE 20/1 C 20/1 A 20/1 0.54 24 FURNITURE SYSTEMS FURNITURE SYSTEMS 38 39 SPARE 41 0.18 40/2 B 20/1 0.54 0.54 FURNITURE SYSTEMS FURNITURE SYSTEMS 40 C 20/1 0.36 TIME WARNER 42 REMARKS: ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "G" = GFCI CB "H" = CB CLIP "A" = ARC FAULT CB "S" = SHUNT TRIP CB PHASE TOTALS: PHASE A: PHASE B: PHASE C: 2.88 4.14 2.70 9.72 kVAC LOAD SUMMARY: Total kVA -LTG: Total kVA -HVAC: Total kVA-MISC: Total kVA-REC: 1 st 1 OKVA REC: BALANCE OF REC: kVAC x 0.00 x 0.00 x 0.00 x 9.72 9.72 x 0.00 x D.F. 1.25 1.00 1.00 1.00 0.50 = = = = = = TOTAL kVAD: FEEDER DEMAND: kVAD 0.00 0.00 0.00 9.72 0.00 9.72 27.00 kVAD A VOLTAGE: 208Y/12OV, 30, 4W AMPS: 250 EXISTING PANEL: P4C 0.18 MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC XX ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C B's 0.54 C 20/1 FURNITURE SYSTEMS 0.54 I I I I NI I I I I I I I I I I I CKT DESCRIPTION RELEASED FOR CONSTRUCTION MISC. C/B C/B MISC. HVAC Suubjecktio aompdiianme with ®III regofatimms LTG of State and Uncal Endes LTG ICltp at Caimal ntro DATE: 02/23/18 20/1 Nick Mishler I I I I NI I I I I I I I I I I I CKT DESCRIPTION LTG REC HVAC MISC. C/B C/B MISC. HVAC REC LTG DESCRIPTION LTG CKT 1 EWC 0.18 20/1 A 20/1 1 20/1 20/1 A 20/1 2 3 FURNITURE SYSTEMS 0.54 20/1 B 20/1 3 FURNITURE SYSTEMS 0.54 20/1 20/1 4 5 FURNITURE SYSTEMS 0.54 20/1 C 20/1 0.10 5 FIRE ALARM PANEL 0.54 6 7 FURNITURE SYSTEMS 0.54 20/1 A FURNITURE SYSTEMS 6 7 8 9 FURNITURE SYSTEMS 0.54 20/1 B 100/3 0.54 COMPUTER ROOM PANEL "CR" 10 1 11 FURNITURE SYSTEMS 0.54 20/1 C 20/1 20/1 B 20/1 0.54 12 13 FURNITURE SYSTEMS 0.54 20/1 A 2D/1 FURNITURE SYSTEMS 0.54 20/1 FURNITURE SYSTEMS C 20/1 14 15 FURNITURE SYSTEMS 0.54 20/1 B 20/1 12 0.54 FURNITURE SYSTEMS FURNITURE SYSTEMS 20/1 16 17 FURNITURE SYSTEMS 0.54 20/1 C 20/1 FURNITURE SYSTEMS 0.54 14 FURNITURE SYSTEMS FURNITURE SYSTEMS 18 19 VENDING 0.18 20/1 A 20/1 0.54 0.54 FURNITURE SYSTEMS FURNITURE SYSTEMS 16 20 21 VENDING 0.18 20/1 B 20/1 C 20/1 0.54 0.54 FURNITURE SYSTEMS FURNITURE SYSTEMS 22 23 HIVE 0.72 20/1 C 20/1 20/1 0.54 1 A 20/1 FURNITURE SYSTEMS 0.54 24 25 REFRIGERATOR 0.18 20/1 A 20/1 FURNITURE SYSTEMS 0.54 20/1 FURNITURE SYSTEMS B 2D/1 26 27 COFFEE MAKER 0.18 20/1 B 20/1 22 0.54 FURNITURE SYSTEMS FURNITURE SYSTEMS 20/1 28 29 COUNTER TOP 0.18 20/1 C 20/1 FURNITURE SYSTEMS 0.54 24 FURNITURE SYSTEMS FURNITURE SYSTEMS 30 31 MECHANICAL ROOM 0.18 20/1 A 20/1 0.54 0.54 FURNITURE SYSTEMS FURNITURE SYSTEMS 26 32 33 COUNTER TOP 0.18 20/1 B 20/1 B 20/1 0.54 0.54 FURNITURE SYSTEMS FURNITURE SYSTEMS 34 35 COUNTER TOP 0.18 20/1 C 20/1 20/1 0.54 C 20/1 FURNITURE SYSTEMS 0.54 36 37 MICROWAVE 0.18 20/1 A 20/1 FURNITURE SYSTEMS 0.90 20/1 CONFERENCE 412 A 20/1 38 39 MICROWAVE 0.18 20/1 B 20/10 0 10.90 32 -90 FURNITURE SYSTEMS CONFERENCE 418 20/1 40 41 REFRIGERATOR 0.18 20/1 C 20/1 FURNITURE SYSTEMS 0.90 34 CONFERENCE 439 FURNITURE SYSTEMS 1 42 REMARKS: PHASE TOTALS: C 2D/1 LOAD SUMMARY: kVAC x D.F. = kVAD 37 ALL CB'S SHALL BE SWD/HID & HACR PHASE A: 5.04 20/1 A 20/1 0.54 FURNITURE SYSTEMS RATED. PROVIDE THE FOLLOWING WHERE PHASE B: 5.40 Total kVA -LTG: 0.00 x 1.25 = 0.00 INDICATED: PHASE C: 6.04 Total kVA -HVAC: 0.00 x 1.00 = 0.00 D.F. 1.25 1.00 1.00 1.00 0.50 "G" = GFCI CB kVAD 0.00 0.60 2.00 10.00 5.98 18.58 51.61 16.48 kVAC Total kVA-MISC: 0.00 x 1.00 = 0.00 kVAC 0.00 0.00 0.00 19.62 10.00 9.62 "H" = CB CLIP D.F. 1.25 1.00 1.00 1.00 0.50 = = = = = = TOTAL kVAD: FEEDER DEMAND: Total kVA-REC: 16.48 VOLTAGE: 208Y/12OV, 30, 4W AMPS: 400 EXISTING PANEL: P4A MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC XX ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C B's "A" = ARC FAULT CB 1st 10KVA REC: 10.00 x 1.00 = 10.00 "S" = SHUNT TRIP CB BALANCE OF REC: 6.48 x 0.50 = 3.24 TOTAL kVAD: 13.24 kVAD FEEDER DEMAND: 36.78 A VOLTAGE: 208Y/12OV, 30, 4W MAIN C/B XX ISOLATED GROUND BAR AMPS: 400 MAIN LUGS ONLY 200% NEUTRAL SURFACE MOUNTED DOUBLE LUGS XX RECESSED MOUNTED FEED THRU LUGS EXISTING PANEL P4 kAIC SUB FEED C B's CKT DESCRIPTION LTG REC HVAC MISC, C/B C/B MISC. HVAC REC LTG DESCRIPTION Client Approval: CKT 1 FURNITURE SYSTEMS 1 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 2 3 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 01 /26/18 FURNITURE SYSTEMS 4 5 FURNITURE SYSTEMS 0.54 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 6 7 TELEPHONE BACK BOARD 0.18 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 8 9 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 FURNITURE SYSTEMS 10 11 FURNITURE SYSTEMS 0.54 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 12 13 FURNITURE SYSTEMS 0.54 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 14 15 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 FURNITURE SYSTEMS 16 17 FURNITURE SYSTEMS 0.54 20L1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 18 19 FURNITURE SYSTEMS 0.54 1 20/1 20/1 1 A 20/1 0.54 FURNITURE SYSTEMS 20 21 FURNITURE SYSTEMS 0.54 20/1 20/1 B 2D/1 0.54 FURNITURE SYSTEMS 22 23 FURNITURE SYSTEMS 0.54 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 24 25 FURNITURE SYSTEMS 0.54 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 26 27 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 FURNITURE SYSTEMS 28 29 FURNITURE SYSTEMS 0.54 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 30 31 FURNITURE SYSTEMS 0.54 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 32 33 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 FURNITURE SYSTEMS 34 35 FURNITURE SYSTEMS 0.54 20/1 20/1 C 2D/1 0.54 FURNITURE SYSTEMS 36 37 FURNITURE SYSTEMS 0.54 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 38 39 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.60 0.54 FURNITURE SYSTEMS 40 41 SPARE 7.56 9.74 7.26 24.56 kVAC 20/1 20/1 C 20/1 D.F. 1.25 1.00 1.00 1.00 0.50 1 kVAD 0.00 0.60 2.00 10.00 5.98 18.58 51.61 ISPARE VOLTAGE: 208Y/12OV, 30, 4W AMPS: 225 EXISTING PANEL: P413 42 REMARKS: ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "G" = GFCI CB "H" = CB CLIP "A" = ARC FAULT CB "S" = SHUNT TRIP CB PHASE TOTALS: PHASE A: PHASE B: PHASE C: 6.66 7.02 5.94 19.62 kVAC LOAD SUMMARY: Total kVA -LTG: Total kVA -HVAC: Total kVA-MISC: Total kVA-REC: 1st 10KVA REC: BALANCE OF REC: kVAC 0.00 0.00 0.00 19.62 10.00 9.62 x x x x x x D.F. 1.25 1.00 1.00 1.00 0.50 = = = = = = TOTAL kVAD: FEEDER DEMAND: kVAD 0.00 0.00 0.00 10.00 4.81 14.81 41.14 kVAD A VOLTAGE: 208Y/12OV, 30, 4W AMPS: 400 EXISTING PANEL: P4A MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC XX ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C B's CKT DESCRIPTION LTG REC HVAC MISC. C/B C/B MISC. HVAC REC LTG DESCRIPTION Client Approval: CKT 1 FURNITURE SYSTEMS 0.54 20L1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 2 3 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 01 /26/18 FURNITURE SYSTEMS 4 5 FURNITURE SYSTEMS 0.54 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 6 7 FURNITURE SYSTEMS 0.54 20/1 20/1 A 2D/1 0.54 FURNITURE SYSTEMS 8 9 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 FURNITURE SYSTEMS 10 11 FURNITURE SYSTEMS 0.54 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 12 13 FURNITURE SYSTEMS 0.54 20L1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 14 15 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 FURNITURE SYSTEMS 16 17 FURNITURE SYSTEMS 0.54 20/1 20/1 C 1 20/1 0.54 FURNITURE SYSTEMS 18 19 FURNITURE SYSTEMS 0.54 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 20 21 FURNITURE SYSTEMS 0.54 20L1 20/1 B 20/1 0.54 FURNITURE SYSTEMS 22 23 FURNITURE SYSTEMS 0.54 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 24 25 FURNITURE SYSTEMS 0.54 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 26 27 FURNITURE SYSTEMS 0.54 20/1 20/1 B 20/1 0.54 FURNITURE SYSTEMS 28 29 FURNITURE SYSTEMS 0.54 20/1 20/1 C 20/1 0.54 FURNITURE SYSTEMS 30 31 FURNITURE SYSTEMS 0.54 20/1 20/1 A 20/1 0.54 FURNITURE SYSTEMS 32 33 FOCUS ROOMS 1.08 20/1 20/1 B 20/1 1.26 FOCUS ROOM 409 34 35 COPIER 0.18 20/1 20/1 C 20/1 1.08 FOCUS ROOM 408 36 37 COPIER 0.18 20/1 20/1 A 20/1 0.90 RECEPTION 401 38 39 41 CU -4-1 25/2 20/1 20/1 B 20/1 2.00 C 20/1 0.60 WATER HEATER CONDENSATE PUMP 40 42 REMARKS: ALL CB'S SHALL BE SWD/HID & HACR RATED. PROVIDE THE FOLLOWING WHERE INDICATED: "G" = GFCI CB "H" = CB CLIP "A" = ARC FAULT CB "S" = SHUNT TRIP CB PHASE TOTALS: PHASE A: PHASE B: PHASE C: 7.56 9.74 7.26 24.56 kVAC LOAD SUMMARY: Total kVA -LTG: Total kVA -HVAC: Total kVA-MISC: Total kVA-REC: 1st 10KVA REC: BALANCE OF REC: kVAC 0.00 0.60 2.00 21.96 10.00 11.96 x x x x x x D.F. 1.25 1.00 1.00 1.00 0.50 = = = = = = TOTAL kVAD: FEEDER DEMAND: kVAD 0.00 0.60 2.00 10.00 5.98 18.58 51.61 kVAD A VOLTAGE: 208Y/12OV, 30, 4W AMPS: 225 EXISTING PANEL: P413 I MAIN C/B MAIN LUGS ONLY SURFACE MOUNTED RECESSED MOUNTED kAIC XX ISOLATED GROUND BAR 200% NEUTRAL DOUBLE LUGS FEED THRU LUGS SUB FEED C B's XX PANELBOARD NOTES: 1. PROVIDE 2 -POLE HANDLE TIES FOR COMMON DISCONNECTING MEANS OF MULTI -WIRE, COMMON NEUTRAL, BRANCH CIRCUITS. CONFIRM AVAILABILITY OF HANDLE TIES WITH MANUFACTURER. PROVIDE 20A/2P CIRCUIT BREAKERS (TYPE AND kAIC RATING TO MATCH PANELBOARD) AS REQUIRED IF HANDLE TIES CAN NOT BE FITTED TO EXISTING CIRCUIT BREAKERS. • Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc SEE NOTE 1 (TYPICAL) I I I I I I I I I I I I I I I I I SEE NOTE 1 (TYPICAL) I ,`,���A 13 nrrenrrpp� No.11400468 - 'a STATE OF 0.o'",SND NP H E L L Y E R LEW AN Approved by: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THEW RK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Electrical Panelboard Schedules No. E-6.04 Drawn by: M E B Checked by: AN Approved by: AN Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: Drawing: Electrical Panelboard Schedules No. E-6.04 QSN-4 T16 -S Energi Savr Node 0-10V and Softswitch QSWS2-2BRLI-WH seeTouch QS Insert 2 Button with Raise/Lower Scene 1 + Off with Raise/Lower 1 gang backbox LOS -CDT -2000 -WH RF Ceiling Dual Technology ------------------ r LRF2-DCRB-WH Occupancy sensorsDaylight Sensor i i i i i LOS -CDT -2000 -WH Ceiling Dual Technology Occupancy sensors i i i i ------------------------J QSM2-4 W -C QS Sensor Module wired and wireless inputs Daylighting Zone #5 5 QSN-4 T16 -S Energi Savr Node 0-10V and Softswitch QSWS2-2BRLI-WH seeTouch QS Insert 2 Button with Raise/Lower Scene 1 + Off with Raise/Lower 1 gang backbox -OS-CDT-2000-WH RF Deiling Dual Technology ------------------ rr LRF2-DCRB-WH Occupancy sensorsDaylight Sensor i i -OS-CDT-2000-WH Deiling Dual Technology Dccupancy sensors -OS-CDT-2000-WH Deiling Dual Technology Dccupancy sensors i i i i LOS -CDT -2000 -WH Ceiling Dual Technology Occupancy sensors -----------------------J QSM2-4 W -C QS Sensor Module wired and wireless inputs Daylighting Zone #6 6 QSN-4 T16 -S Energi Savr Node 0-10V and Softswitch QSWS2-2BRLI-WH seeTouch QS Insert 2 Button with Raise/Lower Scene 1 + Off with Raise/Lower 1 gang backbox LOS -CDT -2000 -WH RF Ceiling Dual Technology ------------------rLRF2-DCRB-WH Occupancy sensors ° Daylight Sensor i i i i i i i i i i i i i i i i i i i i i i i i i i ------------------------J QSM2-4 W -C QS Sensor Module wired and wireless inputs Daylighting Zone #7 7 RELEASED IFCR CONSTRUCTION Suubjecktio aumpdiianme with ®III regulatimms of State and Uncal Endes ICltp of Caimal ntro DATE: 02/23/18 Nick M'shler QSN-4 T16 -S Energi Savr Node 0-10V and Softswitch QSWS2-2BRLI-WH seeTouch QS Insert 2 Button with Raise/Lower Scene 1 + Off with Raise/Lower 1 gang backbox LOS -CDT -2000 -WH RF Ceiling Dual Technology r LRF2-DCRB-WH Occupancy sensors i Daylight Sensor i i i i LOS -CDT -2000 -WH Ceiling Dual Technology Occupancy sensors i i i i i J QSM2-4 W -C QS Sensor Module wired and wireless inputs Daylighting Zone #1 1 QSN-4 T16 -S Energi Savr Node 0-10V and Softswitch QSWS2-2BRLI-WH seeTouch QS Insert 2 Button with Raise/Lower Scene 1 + Off with Raise/Lower 1 gang backbox LOS -CDT -2000 -WH RF Ceiling Dual Technology err LRF2-DCRB-WH Occupancy sensors r Daylight Sensor i i i i i LOS -CDT -2000 -WH Ceiling Dual Technology Occupancy sensors i LOS -CDT -2000 -WH Ceiling Dual Technology Occupancy sensors ------------------------J QSM2-4 W -C QS Sensor Module wired and wireless inputs Daylighting Zone #2 2 QSN-4 T16 -S Energi Savr Node 0-10V and Softswitch QSWS2-2BRLI-WH seeTouch QS Insert 2 Button with Raise/Lower Scene 1 + Off with Raise/Lower 1 gang backbox LOS -CDT -2000 -WH RF Ceiling Dual Technology err LRF2-DCRB-WH Occupancy sensors r Daylight Sensor i i LOS -CDT -2000 -WH Ceiling Dual Technology Occupancy sensors i i i i i i i i i i i i i i i i i i i i ------------------------J QSM2-4 W -C QS Sensor Module wired and wireless inputs Daylighting Zone #3 3 rr� QSN-4 T16 -S Energi Savr Node 0-10V and Softswitch QSWS2-2BRLI-WH seeTouch QS Insert 2 Button with Raise/Lower Scene 1 + Off with Raise/Lower 1 gang backbox LOS -CDT -2000 -WH RF Ceiling Dual Technology err LRF2-DCRB-WH Occupancy sensors i Daylight Sensor i i i i LOS -CDT -2000 -WH Ceiling Dual Technology Occupancy sensors i i i i i LOS -CDT -2000 -WH Ceiling Dual Technology Occupancy sensors i i i i i i i i i i i i i ------------------------J QSM2-4 W -C QS Sensor Module wired and wireless inputs Daylighting Zone #4 4 • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc ,,,, I1111/1,,,,, S TTFR No. 11400468 = •� '• o STATE OF ;IQ ALL LUTRON LIGHTING CONTROL DEVICES SHALL BE PURCHASED THROUGH LIGHTING & CONTROLS, ATTENTION GUY DAY GUY DAY P: 216.741.4545 E: GDAY@E—LIGHTINGCONTROLS.COM LIGHTING & CONTROLS 4503 BROOKPARK ROAD PARMA, OH 44134 H E M E B L L Y E R LEWISi Client Approval: ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Electrical Lighting Contro Diagrams No. E-7.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Electrical Lighting Contro Diagrams No. E-7.04 PART I - ELECTRICAL GENERAL PROVISIONS 1.1 RELATED DOCUMENTS A. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, ALTERNATES, ADDENDA S , AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. CONTRACTORS AND SUBCONTRACTORS SHALL EXAMINE SAME AS WELL AS OTHER DIVISIONS OF THE SPECIFICATIONS WHICH AFFECT WORK UNDER THIS DIVISION. 1.2 SUMMARY A. THIS SECTION INCLUDES GENERAL ADMINISTRATIVE AND PROCEDURAL REQUIREMENTS FOR ELECTRICAL INSTALLATIONS COMMON TO ALL SECTIONS OF DIVISION 16. THE ADMINISTRATIVE AND PROCEDURAL REQUIREMENTS IN THIS SECTION EXPAND AND SUPPLEMENT THE REQUIREMENTS SPECIFIED IN DIVISION 1. 1.3 DESCRIPTION OF WORK A. ELECTRICAL, ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, STRUCTURAL, ETC., AND ALL OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS ARE A PART OF THE CONTRACT DOCUMENTS. B. DRAWINGS AND SPECIFICATIONS ARE TO BE CONSIDERED AS SUPPLEMENTING EACH OTHER. WORK SPECIFIED BUT NOT SHOWN, OR SHOWN BUT NOT SPECIFIED, SHALL BE PERFORMED OR FURNISHED AS THOUGH MENTIONED IN BOTH SPECIFICATIONS AND DRAWINGS. C. VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH CONDITIONS AFFECTING THE INSTALLATION. SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE KNOWLEDGE OF SUCH CONDITIONS AND NO ADDITIONAL COMPENSATION SHALL BE ALLOWED WHERE EXTRA LABOR OR MATERIALS ARE REQUIRED BECAUSE OF IGNORANCE OF THESE CONDITIONS. 1.4 WORK INCLUDES A. INCLUDE ALL LABOR, MATERIAL, EQUIPMENT, SERVICES, AND PERMITS NECESSARY FOR THE PROPER COMPLETION OF ALL ELECTRICAL WORK SHOWN. ITEMS OMITTED, BUT NECESSARY TO MAKE THE ELECTRICAL SYSTEM COMPLETE AND WORKABLE, SHALL BE UNDERSTOOD TO FORM PART OF THE WORK. B. IT IS THE PURPOSE OF THE ELECTRICAL DRAWINGS TO INDICATE THE APPROXIMATE LOCATION OF ALL EQUIPMENT, OUTLETS, ETC. ASCERTAIN EXACT LOCATIONS AND ARRANGE WORK ACCORDINGLY. THE RIGHT IS RESERVED TO EFFECT REASONABLE CHANGES IN THE LOCATION OF OUTLETS UP TO THE TIME OF ROUGHING -IN, WITHOUT ADDITIONAL COST TO THE OWNER. CHANGES IN LOCATION OF OUTLETS OR EQUIPMENT NECESSITATED BY INTERFERENCE WITH THE WORK OF OTHER TRADES SHALL BE MADE ONLY WITH THE CONSENT OF THE ARCHITECT AND ENGINEER OR OWNERS REPRESENTATIVE, AND AT NO ADDITIONAL COST. C. AS USE,P IN THIS SPECIFICATION, "PROVIDE" MEANS„ "FURNJSH AND INSTALL" AND "HVAC" MEANS HEATING, VENTILATING AND AIR CONDITIONING AND POS MEANS PROVIDED UNDER OTHER SECTIONS". "FURNISH" MEANS "TO PURCHASE AND DELIVER TO TJ PROJI�CT SITE COMPLETE WITH EVERY NECESSARY APPURTENANCE AND SUPPORT, AND INSTALL MEANS "TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND PERFORM EVERY OPERATION NECESSARY FOR PROPER INSTALLATION PER CODES AND MANUFACTURERS REQUIREMENTS, TO ESTABLISH SECURE MOUNTING AND CORRECT OPERATION AT THE PROPER LOCATION IN THE PROJECT." D. WORK INCLUDES, BUT IS NOT LIMITED TO: 1. RE -USE OF AND NEW PANELBOARDS AND CIRCUIT BREAKERS 2. FEEDERS AND BRANCH CIRCUIT WIRING 3. HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 4. ELECTRICAL IDENTIFICATION 5. CONDUCTORS AND CABLES 6. GROUNDING AND BONDING 7. RACEWAYS AND BOXES 8. WIRING DEVICES 9. LIGHTING CONTROL DEVICES 10. LUMINAIRES 11. RE -WORKING AND NEW DEVICES TO THE EXISTING FIRE ALARM SYSTEM 12. FIRE STOPPING 13. ELECTRICAL CONNECTIONS TO MECHANICAL HVAC AND PLUMBING EQUIPMENT 14.NAMEPLATES LABELS, AND TAGS 15. COORDINATION DRAWINGS 16. SHOP DRAWINGS 17.OPERATION AND MAINTENANCE INSTRUCTIONS AND MANUALS 18. TESTING E. THE ELECTRICAL DESIGN IS BASED ON THE CURRENT ADOPTED EDITION NFPA 70 - "THE NATIONAL ELECTRICAL CODE'. THE CONTRACTOR SHALL INCLUDE IN THEIR BID THE COST OF INSTALLING MATERIALS AND EQUIPMENT NECESSARY TO SATISFY ALL LOCAL, AND/OR STATE CODES. 1.5 WORK OR MATERIALS NOT INCLUDED A. THE EXACT WIRING REQUIREMENTS SHALL BE AS RECOMMENDED BY THE MANUFACTURER OF THE EQUIPMENT AND SHALL BE VERIFIED BY THE ELECTRICAL CONTRACTOR WITH THE EQUIPMENT MANUFACTURER BEFORE SUBMITTING THE BID. B. STARTERS SUPPLIED AS AN INTEGRAL PART OF THE EQUIPMENT SHALL BE FURNISHED UNDER THE DIVISION PROVIDING THE EQUIPMENT. POWER WIRING DISCONNECT SHALL BE UNDER DIVISION 16. ALL OTHER STARTERS AND AUXILIARY CONTROL EQUIPMENT SHALL BE SUPPLIED AND WIRED UNDER DIVISION 16, UNLESS OTHERWISE SHOWN. 1.6 RELATED WORK SPECIFIED ELSEWHERE A. DIVISION 13 - SPECIAL CONSTRUCTION B. DIVISION 15 - MECHANICAL 1.7 CODES, PERMITS, AND FEES A. INSTALL WORK IN FULL ACCORDANCE WITH RULES AND REGULATIONS OF STATE, COUNTY, AND CITY AUTHORITIES HAVING JURISDICTION (AHJ OVER PREMISES. THIS SHALL INCLUDE SAFETY REQUIREMENTS OF THE STATE OF INDANA DEPARTMENTS OF COMMERCE AND NATURAL RESOURCES. DO NOT CONSTRUE THIS AS RELIEVING CONTRACTOR FROM COMPLIANCE WITH ANY REQUIREMENTS OF SPECIFICATION WHICH ARE IN EXCESS OF CODE RE UIREMENTS AND NOT IN CONFLICT THEREWITH. WORK SHALL BE INSTALLED IN Q ACCORDANCE WITH ALL APPLICABLE PROVISIONS OF THE NATIONAL ELECTRICAL CODE, AS INTERPRETED BY THE LOCAL AUTHORITY HAVING JURISDICTION, AS WELL AS ANY FURTHER MODIFICATIONS OR REGULATIONS PUBLISHED BY LOCAL OR STATE AUTHORITIES. C. GIVE PROPER AUTHORITIES NOTICE AS REQUIRED BY LAW RELATIVE TO THE WORK IN THEIR CHARGE. COMPLY WITH THE REGULATIONS REGARDING TEMPORARY ENCLOSURES, OBSTRUCTIONS, OR EXCAVATIONS AND PAY ALL LEGAL FEES INVOLVED. D. SECURE AND PAY FOR PERMITS AND CERTIFICATES OF INSPECTIONS INCIDENTAL TO THIS WORK, AS REQUIRED BY ALL FOREGOING AUTHORITIES. BE RESPONSIBLE FOR PAYMENTS TO ALL PUBLIC UTILITIES FOR WORK PERFORMED BY THEM IN CONNECTION WITH PROVISION OF SERVICE CONNECTIONS REQUIRED UNDER THIS DIVISION OF SPECIFICATIONS. TURN OVER CERTIFICATES OF APPROVAL TO THE CONSTRUCTION MANAGER AND/OR OWNER PROMPTLY WHEN RECEIVED, AND BEFORE PAYMENT IS MADE FOR THE WWORK. DELIVER ALL CERTIFICATES TO ARCHITECT IN DUPLICATE. E. PROVISIONS OF THE LATEST REVISIONS TO THE FOLLOWING CODES AND STANDARDS SHALL BE FOLLOWED WHERE APPLICABLE: 1. INDIANA ADOPTED STATE BUILDING CODES (IBC) 2. CITY OF INDIANAPOLIS BUILDING CODES 3. NFPA 70 - NATIONAL ELECTRIC CODE (NEC) 4. NFP//A 101 - LIFE SAFETY CODE 6. AIMERICANS WIITH SDISABILITIES ACT (ADA) 7. FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) 1.8 COORDINATION WITH OTHER TRADES A. CONSULT THE DRAWINGS, PRODUCT DATA, AND SHOP DRAWINGS COVERING THE WORK FOR VARIOUS OTHER TRADES, THE FIELD LAYOUTS OF THE CONTRACTORS FOR THE TRADE AND MAKE ADJUSTMENTS ACCORDINGLY IN LAYING OUT THE ELECTRICAL WORK. B. KEEP FULLY INFORMED OF THE PROGRESS OF THE GENERAL CONSTRUCTION. INSTALL WORK THAT IS TO BE CONCEALED WITHIN THE BUILDING CONSTRUCTION IN SUFFICIENT TIME TO SECURE PROPER LOCATION WITHOUT DELAY TO THE WORK OF OTHER TRADES. ALL CONDUIT AND OUTLET BOXES CONCEALED IN MASONRY CONSTRUCTION SHALL BE INSTALLED DURING WALL CONSTRUCTION. ATTEND TO ELECTRICAL WORK DURING THE PROGRESS OF BUILDING -IN TO PREVENT MISALIGNMENTS AND DAMAGES TO THE ELECTRICAL WORK. C. EXAMINE THE WORK OF OTHER TRADES WHEN IT COMES IN CONTACT WITH, OR IS COVERED BY WORK IN THIS DIVISION. DO NOT ATTACH TO, COVER UP, OR FINISH AGAINST ANY DEFECTIVE WORK, OR INSTALL WORK IN A MANNER WHICH WILL PREVENT PROPER INSTALLATION OF THE WORK OF OTHER TRADES. D. ALL OUTLETS, SWITCHES, AND RECEPTACLES SHALL BE CENTERED WITH REGARD TO PANELING, WALL COVERINGS, TRIM, EQUIPMENT, ETC., AND SHALL LINE UP WITH EITHER BOTTOM OR TOP OF MASONRY COURSES. CHANGES TO THE SPECIFIED MOUNTING HEIGHTS OF ANY DEVICE SHALL BE APPROVED BY THE OWNER'S REPRESENTATIVE BEFORE ROUGH -IN. E. TAKE ALL FIELD MEASUREMENTS NECESSARY AND ASSUME RESPONSIBILITY FOR THEIR ACCURACY. F. BEFORE BEGINNING CONSTRUCTION OF THE PROJECT THE CONTRACTOR SHALL PROVIDE TO THE MECHANICAL CONTRACTOR, MARKED -UP PRINTS INDICATING ALL ELECTRICAL ITEMS WHICH AFFECT THE LOCATION OF HEATING, VENTILATING AIR CONDITIONING PLUMBING, PIPING, AND DUCTWORK. THESE SHALL INCLUDE BUT NbT BE LIMITED TO FULL BOXES, CONDUIT, ETC. 1.9 EQUIPMENT AND MATERIALS A. ALL EQUIPMENT DEVICES AND MATERIALS USED ON THIS PROJECT SHALL BE NEW AND U.L. LISTED AND LAHELED FOR THE APPLICATION. B. PROVIDE MATERIAL AND LABOR WHICH IS NEITHER DRAWN NOR SPECIFIED, BUT WHICH IS OBVIOUSLY A COMPONENT PART OF, AND NECESSARY TO COMPLETE WORK AND WHICH IS CUSTOMARILY A PART OF WORK OF SIMILAR CHARACTER. C. EQUIPMENT AND MATERIALS FOR THE CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE PROTECTED BY SAME UNTIL FORMALLY ACCEPTED BY THE OWNER. D. ALL MANUFACTURERS OF ELECTRICAL EQUIPMENT SHALL VERIFY TO THE SATISFACTION OF THE CONTRACTOR AND ENGINEER THAT THEIR EQUIPMENT WILL FUNCTION PROPERLY UNDER THE CONDITIONS OF USE, AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. DIMENSIONS, WEIGHTS, OPERATING CHARACTERISTICS AND ALL OTHER RELATED APPURTENANCES SHALL BE VERIFIED BEFORE SUBMITTAL OF SHOP DRAWINGS. 1.10 MATERIAL SUBSTITUTIONS A. BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVES. DRAWINGS AND SPECIFICATIONS ARE BASED ON THE PRODUCTS SPECIFIED BY TYPE MODEL AND SIZE AND THUS ESTABLISH MINIMUM QUALITIES, WHICH SUBSTITUTES MUST MEET TO QUALIFY FOR REVIEW. B. SHOULD THE CONTRACTOR PROPOSE TO FURNISH MATERIALS EQUIPMENT AND DEVICES, OTHER THAN THOSE SPECIFIED AND LISTED, THE CONTRACTR SHALL SUBMIT A WRITTEN REQUEST FOR SUBSTITUTIONS, TO THE ENGINEER AT LEAST TEN (10) BUSINESS DAYS PRIOR TO BID OPENING. THE REQUEST SHALL BE AN ALTERNATE 0 THE ORIGINAL BID AND SHALL INCLUDE AND BE ACCOMPANIED WITH COMPLETE SPECIFICATIONS CUT SHEET SUBMITTAL AS OUTLINED IN THIS SPECIFICATION SECTION, COMPLETE WITH DESCRIPTIVE 4EMS.FAC NDICAfiEBANY ADDITIONS TOR GDEDUCTIONSETO) THEN CONTRACTAPRICEAWITH THE SUBSTITUTION SUBMITTAL AND ON THE BID FORM. C. ACCEPTANCE OR REJECTION OF THE PROPOSED SUBSTITUTIONS SHALL BE SUBJECT TO APPROVAL OF THE ARCHITECT AND ENGINEER. IF REQUESTED, THE CONTRACTOR SHALL SUBMIT INSPECTION SAMPLES OF BOTH THE SPECIFIED AND THE PROPOSED SUBSTITUTE ITEMS. D. IF ANY SUBSTITUTIONS ARE APPROVED, AN ADDENDUM LISTING THE APPROVED ITEMS) WILL BE ISSUED TO ALL BIDDING CONTRACTORS PRIOR TO THE BID DATE. E. IN ALL CASES WHERE SUBSTITUTIONS ARE PERMITTED THE CONTRACTOR SHALL BEAR ANY EXTRA COST OF EVALUATING THE EQUALITY OF THE MATERIAL AND EQUIPMENT TO BE INSTALLED. F. WHERE ONLY ONE MAKE IS NAMED IN THE SPECIFICATIONS OR ON THE DRAWINGS, IT SHALL BE PROVIDED. G. VERBAL REQUESTS OR APPROVALS SHALL NOT BE BINDING ON THE ENGINEER OR OWNER. 1.11 QUALITY ASSURANCE A. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: UNDERWRITER LABORATORIES, INC. UL LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY C EPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. ��;�,���� RELEASES IFR DmW3TRlllCTI�N 5uuh�j�o�ktio aumipdiian�c®wlNo ®III r�gwf�timns rn95tal� emd Ilmeal Or'adle�� IC'Itp� o�F Cairrnrel "��� Dr�TEa 02/23/18 1.12 SUBMITTALS A. SHOP DRAWINGS AND PRODUCT DATA 1. PREPARE SHOP DRAWINGS AND PRODUCT DATA FOR ELECTRICAL EQUIPMENT WITH ADEQUATE DETAILS AND SCALES AS NECESSARY TO CLEARLY SHOW CONSTRUCTION. INDICATE OPERATING CHARACTERISTICS FOR EACH REQUIRED ITEM AND DESIGN CONDITIONS FOR EACH. CLEARLY IDENTIFY EACH ITEM ON THE DRAWINGS AS TO MARK, LOCATION, AND USE. 2. THIS CONTRACTOR SHALL REVIEW, STAMP WITH APPROVAL AND SUBMIT, WITH REASONABLE PROMPTNESS AND IN ORDERLY SEQUENCE SO AS TO CAUSE NO DELAY IN WORK OR IN THE WORK OF ANY OTHER CONTRACTOR, ALL SHOP DRAWINGS AND SAMPLES REQUIRED BY THE CONTRACT DOCUMENTS. SHOP DRAWINGS NOT STAMPED WITH CONTRACTOR APPROVAL WILL BE RETURNED FOR REPROCESSING. THE SUBMITTALS WILL BE REVIEWED ONLY FOR GENERAL COMPLIANCE AND NOT FOR DIMENSIONS, QUANTITIES, ETC. 3. IF THE SUBMITTAL SHOWS VARIATIONS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS FOR ANY REASON, THE CONTRACTOR SHALL MAKE MENTION OF SUCH VARIATION IN A LETTER OF TRANSMITTAL. THE CONTRACTOR SHALL NOTE IN RED ON THE SUBMITTAL ANY CHANGE IN DESIGN OR DIMENSION ON THE ITEMS SUBMITTED INCLUDING CHANGES MADE BY THE MANUFACTURER WHICH MAY DIFFER FROM CATALOG INFORMATION. 4. CONTRACTOR FURTHER AGREES THAT IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS AND THE CONTRACT DOCUMENTS IN THE FORM OF DESIGN DRAWING AND SPECIFICATIONS ARE DISCOVERED, EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY THE ENGINEER, THE DESIGN DRAWINGS, AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED. 5. THE SUBMITTALS THAT ARE RETURNED SHALL BE USED FOR PROCUREMENT. THE RESPONSIBILITY OF CORRECT PROCUREMENT REMAINS SOLELY WITH THE CONTRACTOR. THE SUBMITTAL REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR ERRORS OR OMISSIONS AND DEVIATIONS FROM THE CONTRACT REQUIREMENTS. 6. IN CHECKING SHOP DRAWINGS, THE ARCHITECT AND ENGINEER WILL MAKE EVERY EFFORT TO DETECT AND CORRECT ERRORS, OMISSIONS, AND INACCURACIES IN SUCH DRAWINGS. HOWEVER, FAILURE TO DETECT ERRORS, OMISSIONS, AND INACCURACIES SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR THE PROPER AND COMPLETE INSTALLATION IN ACCORDANCE WITH THE INTENT OF THE CONTRACT DOCUMENTS. 7. CONTRACTOR AGREES THAT SHOP DRAWING SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS; THAT THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN, THAT THEY DEMONSTRATE THEIR UNDERSTANDING BY INDICATING WHICH EQUIPMENT AND MATERIAL THEY INTEND TO FURNISH AND INSTALL, AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS THEY INTEND TO USE. 8. SHOP DRAWINGS SHALL CLEARLY INDICATE ALL DIMENSIONAL DATA FOR ALL PARTS OF THE ITEM, TYPES AND MATERIALS FOR ALL CONNECTIONS, FINISHES, THE EXACT RELATION OF THE ITEM TO ADJACENT MATERIALS AND EQUIPMENT IN THE COMPLETED STRUCTURE INCLUDING CLEARANCE, ANY NECESSARY ISOLATION AND FASTENING METHODS AND DEVICES AND MECHANICAL AND ELECTRICAL CONNECTIONS. 9. SUBMIT NEWLY PREPARED INFORMATION, DRAWN TO ACCURATE SCALE. HIGHLIGHT, ENCIRCLE, OR OTHERWISE INDICATE DEVIATIONS FROM THE CONTRACT DOCUMENTS. DO NOT REPRODUCE CONTRACT DOCUMENTS OR COPY STANDARD INFORMATION AS THE BASIS OF SHOP DRAWINGS. STANDARD INFORMATION PREPARED WITHOUT SPECIFIC REFERENCE TO THE PROJECT IS NOT CONSIDERED SHOP DRAWINGS AND WILL BE CAUSE FOR REJECTION. 10.SHOP DRAWINGS AND PRODUCT DATA SHALL BE SUBMITTED AS FOLLOWS: a. CONFORM TO SUBMITTAL REQUIREMENTS OUTLINED IN DIVISION 1 OF THESE SPECIFICATIONS. b. WHERE CONTENTS OF SUBMITTAL LITERATURE INCLUDE DATA NOT PERTINENT TO THE SUBMITTAL, CLEARLY INDICATE WHICH PORTION OF CONTENT IS BEING SUBMITTED FOR REVIEW. 11. SHOP DRAWINGS SHALL INCLUDE FABRICATION AND INSTALLATION DRAWINGS, SETTING DIAGRAMS, SCHEDULES, PATTERNS, TEMPLATES AND SIMILAR DRAWINGS. ALSO, INCLUDE THE FOLLOWING INFORMATION: a. DIMENSIONS. b. IDENTIFICATION OF PRODUCTS AND MATERIALS INCLUDED. c. COMPLIANCE WITH SPECIFIED STANDARDS. d. NOTATION OF COORDINATION REQUIREMENTS. e. NOTATION OF DIMENSIONS ESTABLISHED BY FIELD MEASUREMENT. 12. WHERE ADDITIONAL INSTALLATION DRAWINGS, WIRING DIAGRAMS OR OTHER DRAWINGS ARE SPECIFIED AS A PART OF THE SUBMITTAL, THEY SHALL BE SUBMITTED AT THE SAME TIME WITH SHOP DRAWINGS AND PRODUCT DATA. PARTIAL SUBMITTALS ARE NOT ACCEPTABLE. 13. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL MATERIAL ITEMS AS OUTLINED IN THESE SPECIFICATIONS. ANY DEVIATIONS FROM CONTRACT REQUIREMENTS MUST BE CLEARLY INDICATED ON SHOP DRAWINGS AND JUSTIFICATION FOR THEIR CONSIDERATION MUST BE INCLUDED. 14. APPROVAL OF SUBMITTAL ITEMS SHALL NOT PRECLUDE REJECTION OF THOSE ITEMS UPON DISCOVERY OF DEFECTS IN THEM PRIOR TO FINAL ACCEPTANCE OF COMPLETE WORK. 15. WHEN TWO OR MORE ITEMS OF THE SAME EQUIPMENT ARE REQUIRED (I.E. - LUMINAIRES, WIRING DEVICES, ETC.), EQUIPMENT ITEMS SHALL BE OF THE SAME MANUFACTURER. 16. SUBMIT A MINIMUM OF SIX 6) COPIES OF SHOP DRAWINGS TO THE ARCHITECT. THE ARCHITECT AND ENGINEE SHALL EACH RETAIN ONE (1) COPY AND RETURN THE REMAINDER TO THE CONTRACTOR WHO SHALL DISTRIBUTE COPIES AS RE UIRED TO PROPERLY CONDUCT THE WORK, INCLUDING REQUIREMENTS OF THE OPERATINGQMANUAL. 17. SHOP DRAWINGS AND PRODUCT DATA INCLUDES: a. WIRING DEVICES b. LIGHTING CONTROL DEVICES c. LUMINAIRES, LAMPS, AND BALLASTS d. FIRE ALARM DEVICES AND SYSTEM MODIFICATION DRAWINGS DESIGNED AND STAMPED BY A STATE CERTIFIED FIRE ALARM SYSTEM DESIGNER, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: i. BATTERY CALCULATIONS ii. FLOOR PLANS INDICATING LOCATION OF ALL FIRE ALARM DEVICES. iii. VOLTAGE DROP CALCULATIONS FOR ALL WIRING AND WIRE TYPES. iv. MANUFACTURER MODEL NUMBER AND LISTING INFORMATION FOR ALL DEVICES AND WIRING BEING PROVIDED. v. LOCATION OF ALL REQUIRED SYNCHRONIZATION UNITS IF REQUIRED. vi. POWER EXTENDER PANELS, ADDRESSABLE MODULES, ETC. B. DESIGN DRAWINGS 1. THE DESIGN DRAWINGS, AS SUBMITTED, ARE DIAGRAMMATIC AND ARE NOT INTENDED TO SHOW EXACT LOCATION OF EQUIPMENT, CONDUITS, ETC. UNLESS DIMENSIONS ARE GIVEN. DRAWINGS ARE NOT TO BE SCALED. EQUIPMENT, CONDUIT, ETC. TO BE INSTALLED ALONG THE GENERAL PLANS SHOWN ON THE DRAWINGS, BUT KEEPING IN MIND ACTUAL BUILDING CONDITIONS WHICH MUST BE CONFIRMED WITHIN THE ACTUAL WORK. 2. IF THIS CONTRACTOR PROPOSES TO INSTALL EQUIPMENT REQUIRING SPACE CONDITIONS OTHER THAN THOSE AS SPECIFIED AND OR SHOWN ON THE DESIGN DRAWINGS, OR TO REARRANGE THE EQUIPMENT, HE SHAL ASSUME FULL RESPONSIBILITY FOR THE REARRANGEMENT OF THE SPACE AND SHALL OBTAIN THE FULL APPROVAL OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. C. COORDINATION DRAWINGS 1. BEFORE BEGINNING CONSTRUCTION OF THE PROJECT, THE CONTRACTOR SHALL PROVIDE TO THE MECHANICAL CONTRACTOR MARKED UP PRINTS INDICATING ALL ELECTRICAL WORK WHICH AFFECTS LOCATION OF HEATING, VENTILATING, AIR CONDITIONING, PLUMBING PIPING, FIRE PROTECTION, AND DUCTWORK. REFER TO DIVISION 1 AND DIVISION 15 FOR RELATED WORK. 2. COORDINATION DRAWINGS: REFLECTED CEILING PLANS DRAWN TO SCALE AND COORDINATING PENETRATIONS AND CEILING -MOUNTED ITEMS. SHOW THE FOLLOWING: a. CEILING SUSPENSION ASSEMBLY MEMBERS. b. METHOD OF ATTACHING HANGERS TO BUILDING STRUCTURE. c. CEILING -MOUNTED ITEMS INCLUDING LIGHTING FIXTURES, EXIT SIGNAGE, FIRE ALARM DEVICES, CCN, SPEAKERS, ACCESS PANELS, ETC. D. RECORD DRAWINGS 1. EACH CONTRACTOR OR SUBCONTRACTOR FOR ELECTRICAL WORK SHALL KEEP ONE COMPLETE SET OF THE CONTRACT WORKING DRAWINGS ON THE PROJECT SITE ON WHICH THEY SHALL RECORD ANY DEVIATIONS OR CHANGES FROM SUCH CONTRACT DRAWINGS MADE DURING CONSTRUCTION. THESE CHANGES SHALL BE ACCURATELY RECORDED IN RED INK ON THE PRINTS. RECORD DRAWINGS SHALL SHOW CHANGES IN: a. SIZE, TYPE, CAPACITY, ETC. OF ANY MATERIAL, DEVICE, OR PIECE OF EQUIPMENT. b. LOCATION OF ANY DEVICE OR PIECE OF EQUIPMENT. c. LOCATION OF ANY OUTLET OR DEVICE AND ASSOCIATED WIRING. d. ROUTING OF FEEDER CONDUITS. e. BRANCH CIRCUIT NUMBER ASSIGNMENTS. 2. RECORD DRAWINGS SHALL BE KEPT CLEAN AND UNDAMAGED, AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN RECORDING DEVIATIONS FROM WORKING DRAWINGS. 3. AFTER THE PROJECT IS COMPLETED, RECORD SETS OF DRAWINGS SHALL BE DELIVERED TO THE TENANT AND BUILDING MANAGEMENT IN GOOD CONDITION, AS A PERMANENT RECORD OF THE INSTALLATION AS CONSTRUCTED. ALL COSTS FOR PRODUCTION, PRINTING, ETC. SHALL BE BORNE BY THE CONTRACTOR AND SHALL BE INCLUDED IN THE BID. 4. REFER TO DIVISION 1 SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS RELATED TO RECORD DRAWINGS. 5. THIS CONTRACTOR SHALL RECORD ALL CHANGES FROM ORIGINAL DESIGN DRAWINGS WHICH WERE THE INSTALLATION OF THE WORK. THESE CHANGES SHALL BE RECORDED IN RED INK ON THE PRINTS. CHANGES SHALL BE ACCURATELY DIMENSIONED. 6. THIS CONTRACTOR SHALL KEEP AN UPDATED SET OF PRINT , INCLUDING CHANGES, ON THE JOB SITE AT ALL TIMES AND SHALL SUBMIT ONE 1 SET OF UPDATED AND LEGIBLE AS -BUILT PRINTS TO THE ARCHITECT WHEN THE WORK IS COMPLETE. 7. PREPARE RECORD DOCUMENTS IN ACCORDANCE WITH THE REQUIREMENTS IN DIVISION 1 SECTION "PROJECT CLOSEOUT." 8. IN ADDITION TO THE REQUIREMENTS SPECIFIED IN DIVISION 1, INDICATE THE FOLLOWING INSTALLED CONDITIONS (ACCURATELY DIMENSIONED): a. CONCEALED EQUIPMENT, UNITS, DEVICES, ETC., REQUIRING PERIODIC MAINTENANCE OR REPAIR. 9. APPROVED SUBSTITUTIONS, CONTRACT MODIFICATIONS AND ACTUAL EQUIPMENT AND MATERIALS INSTALLED. EQUIPMENT LOCATIONS (EXPOSED AND CONCEALED), DIMENSIONED FROM PROMINENT BUILDING LINES. 1.13 OPERATING/MAINTENANCE MANUALS A. PREPARE FOUR (4) COMPLETE BOUND SETS OF OPERATING/MAINTENANCE MANUALS IN ACCORDANCE WITH IVISION 1 SECTION "PROJECT CLOSEOUT". CONTAINING OPERATING AND MAINTENANCE INSTRUCTIONS, AND MANUFACTURER START-UP REPORTS FOR ALL ELECTRICAL EQUIPMENT AND CONTROLS. B. SERVICE MANUALS SHALL BE ASSEMBLED INTO ONE VINYL COVERED THREE RING "D" TYPE BINDER WITH HARD COVER AND WITH WRITTEN INSTRUCTIONS FOR EACH SYSTEM LISTED IN THE SPECIFICATIONS. C. WRITTEN OPERATING INSTRUCTIONS, SUBMITTAL DRAWINGS, WIRING DIAGRAMS, EQUIPMENT CATALOG DATA SHEETS AND MANUFACTURER'S INSTRUCTIONS SHALL BE ACCOMMODATED INTO 8-1/2" X 11" AND/OR 11' X 17' SIZE. EACH SECTION SHALL BE TABULATED AND INDEXED AS FOLLOWS: 1. FIRST PAGE --- TITLE OF PROJECT, OWNER, ADDRESS, DATE OF SUBMITTAL, NAME OF CONTRACTOR, AND NAME OF ARCHITECT AND ENGINEER. 2. SECOND PAGE --- INDEX 3. FIRST SECTION --- WRITTEN DESCRIPTION OF SYSTEM CONTENTS WHERE ACTUALLY LOCATED IN BUILDING, HOW EACH PART FUNCTIONS INDIVIDUALLY, AND HOW SYSTEM WORKS AS A WHOLE. CONCLUDE WITH A LIST OF ITEMS REQUIRING SERVICE AND EITHER STATE THE SERVICE NEEDED OR REFER TO THE MANUFACTURER'S DATA IN THE BINDER THAT DESCRIBES THE PROPER SERVICE. 4. SECOND SECTION --- A COPY OF EACH SUBMITTAL DRAWING WITH AN INDEX AT THE BEGINNING OF THE SECTION. 5. THIRD SECTION --- A COPY OF EACH MANUFACTURER'S OPERATING INSTRUCTIONS WITH AN INDEX AT THE BEGINNING OF THE SECTION, AND A COPY OF EACH MANUFACTURER'S START UP REPORT FOR (FIRE ALARM, ETC.) 6. FOURTH SECTION --- A COPY OF ALL TEST RESULTS, IN CHART FORM, PERFORMED BY THE CONTRACTOR 7. FIFTH SECTION --- COPIES OF ALL WARRANTIES, APPROVALS, ETC. D. UBMIT ONE �1) COPY TO THE ENGINEER FOR APPROVAL. AFTER APPROVAL, SUBMIT THREE 3) COPIES T THE ARCHITECT FOR DELIVERY TO THE OWNER. 1.14 PRODUCT DELIVERY, STORAGE, AND HANDLING A. DELIVER PRODUCTS TO THE PROJECT PROPERLY IDENTIFIED WITH NAMES, MODEL NUMBERS, TYPES, COMPLIANCE LABELS AND SIMILAR INFORMATION NEEDED FOR IDENTIFICATION. MATERIALS MUST BE ADEQUATELY PACKAGED OR PROTECTED TO PREVENT DETERIORATION DURING SHIPMENT, STORAGE AND HANDLING. B. THE CONTRACTOR SHALL MAKE PROVISIONS FOR THE DELIVERY AND SAFE STORAGE OF HIS MATERIALS AND EQUIPMENT IN COORDINATION WITH THE WORK OF OTHERS. MATERIALS AND EQUIPMENT SHALL BE DELIVERED AT SUCH STAGES OF THE WORK AS WILL EXPEDITE THE WORK AS A WHOLE AND SHALL BE MARKED AND STORED IN SUCH A WAY AS TO BE EASILY CHECKED AND INSPECTED. THE ARRIVAL AND PLACING OF LARGE EQUIPMENT ITEMS SHALL BE SCHEDULED EARLY ENOUGH TO PERMIT ENTRY AND SETTING WHEN THERE IS NO RESTRICTION OR PROBLEM DUE TO SIZE AND WEIGHT. C. MATERIALS SHALL BE STORED TO PROTECT THEM FROM INJURY PRIOR TO INSTALLATION. MATERIAL SHOULD NOT BE STORED DIRECTLY ON THE GROUND OR FLOOR AND SHALL BE KEPT AS CLEAN AND DRY AS POSSIBLE AND FREE FROM DAMAGE OR DETERIORATING ELEMENTS. D. IN GENERAL, DO NOT DELIVER ITEMS OF ELECTRICAL EQUIPMENT TO THE PROJECT SUBSTANTIALLY BEFORE THE TIME OF INSTALLATION. LIMIT EACH SHIPMENT OF BULK AND MULTIPLE -USE MATERIALS TO THE QUANTITIES NEEDED FOR INSTALLATION WITHIN 3 -WEEKS OF RECEIPT. 1.15 PROTECTION OF WORK AND PROPERTY A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFEGUARDING WORK, PROPERTY, AND FACILITIES AGAINST DAMAGE, BOTH HIS OWN AS WELL AS OTHERS, WITH WHICH HE MAY COME INTO CONTACT IN THE PERFORMANCE OF HIS WORK. B. STORED MATERIALS SHALL BE PROTECTED AGAINST DAMAGE FROM WEATHER. PIPE AND DUCT OPENINGS SHALL BE CLOSED WITH CAPS OR PLUGS DURING INSTALLATION. ALL FIXTURES AND EQUIPMENT SHALL BE COVERED AND PROTECTED AGAINST DAMAGE. ANY MATERIALS OR EQUIPMENT DAMAGED AT ANY STAGE IN THE CONSTRUCTION SHALL BE REPLACED OR REPAIRED AND AT THE FINAL COMPLETION, ALL WORK SHALL BE IN A CLEAN, UNBLEMISHED CONDITION. C. FURNISH INFORMATION TO GENERAL CONTRACTOR AS TO SIZE AND LOCATION OF ALL BUILT-IN OPENINGS REQUIRED. DO NOT CUT, REMOVE OR PIERCE: GENERAL OR MECHANICAL INSULATION; FIRE RATED WALLS OR CEILINGS; OR STEEL WORK; WITHOUT PRIOR PERMISSION AND INSTRUCTION. 1.16 CUTTING AND PATCHING A. GENERAL: ALL CUTTING AND PATCHING FOR THE INSTALLATION OF THIS BRANCH OF THE WORK SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR. B. PERFORM CUTTING AND PATCHING IN ACCORDANCE WITH DIVISION 1 SECTION "PROCEDURES, SEPARATE PRIMES." IN ADDITION TO THE REQUIREMENTS SPECIFIED IN DIVISION 1, PERFORM CUTTING, FITTING AND PATCHING OF MECHANICAL EQUIPMENT AND MATERIALS REQUIRED TO: 1. INSTALL NEW WORK. 2. UNCOVER WORK TO PROVIDE FOR INSTALLATION OF ILL-TIMED WORK. 3. REMOVE AND REPLACE DEFECTIVE WORK. 4. REMOVE AND REPLACE WORK NOT CONFORMING TO REQUIREMENTS OF THE CONTRACT DOCUMENTS. 5. INSTALL E UIPMENT AND MATERIALS IN EXISTING STRUCTURE. Q 6. UPON WRITTEN INSTRUCTIONS FROM THE ENGINEER, UNCOVER AND RESTORE WORK TO PROVIDE FOR ENGINEER OBSERVATION OF CONCEALED WORK. 7. CUT, REMOVE AND LEGALLY DISPOSE OF SELECTED ELECTRICAL EQUIPMENT, COMPONENTS AND MATERIALS AS INDICATED, INCLUDING BUT NOT LIMITED TO REMOVAL OF CONDUITS AND CONDUCTORS, JUNCTION BOXES, LUMINAIRES AND TRIM, AND OTHER ELECTRICAL ITEMS MADE OBSOLETE BY THE NEW WORK. C. PROTECTION OF INSTALLED WORK: DURING CUTTING AND PATCHING OPERATIONS PROTECT ADJACENT INSTALLATIONS. D. PROVIDE AND MAINTAIN TEMPORARY PARTITIONS OR DUST BARRIERS ADEQUATE TO PREVENT THE SPREAD OF DUST AND DIRT TO ADJACENT AREAS. E. ALL OPENINGS RE UIRED FOR THIS BRANCH OF WORK SHALL BE ACCOMPLISHED IN TIME TO BE INCORPORATED IN, AND BE COMPATIBLE WITH THE CONSTRUCTION PROGRAM, OTHERWISE THIS CONTRACTOR SHALL BE RESPONSIBLE AND PAY FOR ALL CHANGES MADE NECESSARY FOR HIS FAILURE TO DO SO. PIPE HOLES IN FLOORS AND WALLS SHALL BE CORE DRILLED. F. PATCH EXISTING FINISHED SURFACES AND BUILDING COMPONENTS USING NEW MATERIALS MATCHING EXISTING MATERIALS AND EXPERIENCED INSTALLERS. FOR INSTALLERS' QUALIFICATIONS, REFER TO THE MATERIALS AND METHODS REQUIRED FOR THE SURFACE AND BUILDING COMPONENTS BEING PATCHED. iNiV>yl:SM3111»li•1e; A. ANY CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS AND WALLS SHALL BE FIRE STOPPED PRIOR TO FINISH PATCHING. ALL FIRE STOPPING MATERIALS SHALL BE U.L. "CLASSIFIED", INTUMESCING COMPOUND, DEVICE, OR SHEET RATED TO FUNCTION FOR THIS PURPOSE. ACCORDING TO INSTRUCTIONS PROVIDED, ALL PENETRATIONS IN 1 -HOUR, 2 -HOUR, AND 3 -HOUR FIRE RATED WALLS, FLOORS OR PARTITION ASSEMBLIES SHALL BE SEALED WITH 3M BRAND FIRE BARRIER CAULK, CP -25, OR COMPOSITE SHEET CS -195, OR EQUIVALENT. ALL PENETRATIONS SHALL BE SEALED IN ACCORDANCE WITH UL FIRE RESISTANCE VOLUME II. 1. CAULK P-25 FILL MATERIAL TO COMPLETELY FILL THE ANNULAR SPACE BETWEEN THE INDIVIDUAL CONDUIT AND GYPSUM WALLBOARD WITH A MINIMUM 1/" DIAMETER BEAD OF CAULK APPLIED TO THE PERIMETER OF CONDUIT (UL SYSTEM WL1001). 2. MULTIPLE CONDUITS SHALL BE CONTAINED WITHIN A 28 GAUGE STEEL SLEEVE. CAULK CP -25 FALL MATERIAL TO A DEPTH OF 1" COMPLETELY AROUND THE STEEL SLEEVE. A NOMINAL /a DIAMETER BEAD SHALL BE APPLIED ON BOTH SIDES OF WALL ASSEMBLE. A MINIMUM 1" THICKNESS OF MINERAL WOOL BATT INSULATION SHALL BE PACKED FIRMLY INTO THE STEEL SLEEVE ON BOTH SIDES OF WALL ASSEMBLY AS A PERMANENT FORM. PACKING MATERIAL SHALL BE RECESSED 5 8" FROM SURFACE OF WALL ON BOTH SIDES OF WALL ASSEMBLY. FILL RECESSED CAVITY WITH 1° OF CP -25 CAULK (UL SYSTEMS WL1016). 3. A MINIMUM 1" THICKNESS OF MINERAL WOOL BATT INSULATION SHALL BE PACKED FIRMLY INTO THE MAXIMUM 2" ANNULAR SPACE AS A PERMANENT FORM. A MINIMUM OF 1" OF CP -25 CAULK SHALL FILL THE RECESSED CAVITY, (FOR WALLS, THIS SHALL BE APPLIED ON BOTH SIDES OF THE WALL) (UL SYSTEM CAJ1044). 4. COORDINATE WITH THE ARCHITECT FOR ALL EXACT MATERIAL AND RATINGS AND EXACT DETAILS FOR FIRE STOPPING MATERIALS AND INSTALLATIONS PER ALL NFPA AND UL REQUIREMENTS. 1.18 INTERFERENCES A. BEFORE INSTALLING ANY WORK, THIS CONTRACTOR SHALL SEE THAT IT DOES NOT INTERFERE WITH CLEARANCE REQUIRED FOR LIGHTS, CONDUIT, AND CEILINGS AND FOR FINISH ON BEAMS, COLUMNS, PILASTERS, WALLS OR OTHER STRUCTURAL OR ARCHITECTURAL MEMBERS, AS SHOWN ON CONTRACT DRAWINGS. IF ANY WORK IS SO INSTALLED AND IT LATER DEVELOPS THAT ORIGINAL DESIGN CANNOT BE FOLLOWED, THIS CONTRACTOR SHALL, AT HIS OWN EXPENSE, MAKE SUCH CHANGES IN HIS WORK AS ARCHITECT MAY DIRECT TO PERMIT COMPLETION OF WORK IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. B. INSTALL ADDITIONAL OFFSETS ON PIPING OR DUCTWORK WHERE REQUIRED TO OBTAIN MAXIMUM HEADROOM OR TO AVOID CONFLICT WITH OTHER WORK WITHOUT ADDITIONAL COST TO OWNER. 1.19 INTERRUPTION OF SERVICE A. WHEN WORK PROGRESS MAKES TEMPORARY SHUTDOWN OF SERVICES UNAVOIDABLE SHUTDOWN SHALL BE COORDINATED WITH AND APPROVED BY OWNER SO AS TO CAUSP MINIMUM DISRUPTION TO ESTABLISHED OPERATING ROUTINE. ARRANGE TO WORK AS NECESSARY TO RE-ESTABLISH SERVICE WITHIN SHORTEST POSSIBLE DOWNTIME. IN THOSE INSTANCES WHERE THE LENGTH OF TIME REQUIRED FOR THE SERVICE INTERRUPTION IS NOT ACCEPTABLE TO THE OWNER, UNLESS OTHERWISE INDICATED, FURNISH AND INSTALL TEMPORARY CONNECTIONS AS REQUIRED TO REDUCE THE LENGTH OF TIME OF SERVICE INTERRUPTION TO AN ACCEPTABLE LEVEL. B. REPORT ANY INTERFERENCE BETWEEN WORK UNDER THIS DIVISION AND THAT OF ANY OTHER CONTRACTORS TO ARCHITECT AS SOON AS THEY ARE DISCOVERED. ARCHITECT WILL DETERMINE WHICH EQUIPMENT SHALL BE RELOCATED, REGARDLESS OF WHICH WAS FIRST INSTALLED, AND HIS DECISION SHALL BE FINAL. 1.20 WORKMANSHIP A. WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE BEST PRACTICES OF THE TRADE AND IN A WORK LIKE MANNER AND SHALL NEAT AND RECTILINEAR TO FINISHES. B. ELECTRICAL WORK SHALL BE INSTALLED BY JOURNEYMEN ELECTRICIANS UNDER THE SUPERVISION OF A COMPETENT FOREMAN. 1.21 DEMONSTRATION OF COMPLETE ELECTRICAL SYSTEM A. BEFORE FINAL PAYMENT DEMONSTRATE TO THE OWNER'S SATISFACTION THE PROPER OPERATION OF EACH OF THE SYSTEMS COMPRISING THIS CONTRACT. B. INSTRUCT THE OWNER'S MAINTENANCE PERSONNEL IN THE OPERATION AND MAINTENANCE OF ALL ELECTRICAL EQUIPMENT AND CONTROLS. C. DELIVER TO THE OWNER ALL SPECIAL TOOLS AND APPURTENANCES FOR PROPER OPERATION AND MAINTENANCE OF THE EQUIPMENT PROVIDED AND REQUEST RECEIPT FOR SAME. ATTACH TO THE CONTRACTOR'S REQUEST FOR FINAL PAYMENT. 1.22 CLEANING AND FINISHING A. GENERAL: FOLLOW THE REQUIREMENTS SPECIFIED IN DIVISION 1 SECTION "PROJECT CLOSEOUT." B. IN SO FAR AS THIS DIVISION IS CONCERNED, AT ALL TIMES KEEP PREMISES AND BUILDING IN A NEAT AND ORDERLY CONDITION FOLLOW EXPLICITLY ANY INSTRUCTIONS OF ARCHITECT AND OWNER IN REGARD TO STORING OF MATERIALS, PROTECTIVE MEASURES, CLEANING -UP OF DEBRIS, ETC. C. UPON COMPLETION OF WORK THIS CONTRACTOR SHALL THOROUGHLY CLEAN ALL EQUIPMENT LEAVING EVERYTHING IN WORKING ORDER AT THE COMPLETION OF THIS COMPLETED THEIR WORK. CLEAN LUMINAIRES, OUTLET BOX PLATES PANEL AND CABINET INTERIORS AND EXTERIORS, ETC., OF DIRT, DUST, DEBRIS, PAINT, ETO. 1.23 GUARANTEE AND WARRANTIES A. WARRANT THAT EQUIPMENT AND ALL WORK IS INSTALLED IN ACCORDANCE WITH GOOD ENGINEERING PRACTICE AND THAT ALL EQUIPMENT WILL MEET REQUIREMENTS SPECIFIED. ANY EQUIPMENT FAILING TO PERFORM OR FUNCTION AS SPECIFIED SHALL BE REPLACED WITH COMPLYING EQUIPMENT WITHOUT COST TO THE OWNER. B. THIS CONTRACTOR SHALL GUARANTEE AGAINST DEFECTS OF ALL MATERIALS WORKMANSHIP AND THE COMPLETE OPERATION OF ALL EQUIPMENT AND APPARATUS INSTALLED BY HIM FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE FINAL ACCEPTANCE OF THE ENTIRE WORK AND SHALL GUARANTEE TO REPAIR OR REPLACE AT HIS OWN EXPENSE ANY PART OF THE APPARATUS WHICH MAY SHOW DEFECT DURING THAT TIME PROVIDED SUCH DEFECT IS, IN THE OPINION OF THE ARCHITECT, DUE TO IMPERFECT MATERIAL OR WORKMANSHIP AND NOT TO CARELESSNESS OR IMPROPER USE. PART 2 - PRODUCTS 2.1 RACEWAYS A. ELECTRICAL METALLIC TUBING (EMT) SHALL BE ELECTRO -GALVANIZED AND MANUFACTURED IN ACCORDANCE WITH ANSI C80.3. B. FLEXIBLE METAL CONDUIT (FMC) SHALL CONSIST OF CONTINUOUS LENGTHS OF SPIRALLY WOUND AND INTERLOCKED GALVANIZED STEEL, MANUFACTURED IN ACCORDANCE WITH UL 1. LIQUID TIGHT FLEXIBLE METAL CONDUIT (LFMC) SHALL BE USED IN WET LOCATIONS. C. CONDUIT EXPANSION FITTINGS SHALL BE THREADED HOT -DIPPED GALVANIZED MALLEABLE IRON WITH INTERNAL BONDING ASSEMBLY. D. PROVIDE THREADED MALLEABLE IRON OR STEEL CONNECTORS AND COUPLINGS WITH INSULATED THROATS; MANUFACTURED ELBOWS; LOCKNUTS; AND PLASTIC OR BAKELITE BUSHINGS AT TERMINATIONS, AS NECESSARY. COUPLINGS AND CONNECTORS SHALL BE GLAND AND RING COMPRESSION OR STAINLESS STEEL MULTIPLE POINT LOCKING OR STEEL CONCRETE -TIGHT SET SCREW. COMPRESSION COUPLINGS AND CONNECTORS SHALL FORM POSITIVE GROUND. SET -SCREW CONNECTORS AND COUPLINGS SHALL HAVE WALL THICKNESS EQUAL TO CONDUIT, CASE-HARDENED, HEX -HEAD SCREWS AND SEPARATE GROUND WIRE. BUSHINGS FOR RIGID STEEL AND CONNECTORS FOR EMT SHALL HAVE INSULATING INSERTS THAT MEET REQUIREMENTS OF UL 514 FLAME TEST. E. ACCEPTABLE MANUFACTURER FOR METALLIC RACEWAY SHALL BE AS FOLLOWS: 1. ALFLEX 2. ELECTRI-FLEX 3. GRINNEL CO. 4. 0-Z GEDNEY 2.2 OUTLET BOXES A. OUTLET BOXES ON CONCEALED WORK SHALL BE AT LEAST 4 1116" SQUARE OR OCTAGONAL, GALVANIZED PRESSED STEEL WITH PLASTER RINGS AS REQUI ED. OUTLET BOXES FOR EXPOSED CONDUIT WORK SHALL BE CAST ALUMINUM ALLOY WITH CAST ALUMINUM ALLOY COVERS. B. WHERE INSTALLED IN PLASTER, BOXES SHALL BE FITTED WITH GALVANIZED STEEL PLASTER COVERS OF REQUIRED DEPTH TO FINISH FLUSH WITH FINISHED WALL OR CEILING. C. SWITCH BOXES RECEPTACLE BOXES AND OTHER OUTLET BOXES SHALL BE STANDARD 4 11/16" SQUARE WITH PLASTER RINGS OR GANG COVER AS REQUIRED. D. OUTLET BOXES FOR VARIOUS SYSTEMS AND COMPONENTS SHALL BE AS REQUIRED BY EQUIPMENT MANUFACTURER. E. PROVIDE ONLY ENOUGH CONDUIT OPENINGS TO ACCOMMODATE CONDUITS AT INDIVIDUAL LOCATION. EACH BOX SHALL BE LARGE ENOUGH TO ACCOMMODATE NUMBER AND SIZES OF CONDUITS WIRES AND SPLICES TO MEET NEC REQUIREMENTS BUT SHALL BE AT LEAST SIZE SHOWN dR SPECIFIED. NECESSARY VOLUME SHALL BE OBTAINED BY USING BOXES OF PROPER DIMENSIONS. 2.3 JUNCTION BOXES AND PULL BOXES A. PROVIDE CODE GAUGE GALVANIZED STEEL JUNCTION AND PULL BOXES FOR CONDUIT 1-1 4" TRADE SIZE AND LARGER, WHERE NECESSARY TO FACILITATE INSTALLATION, OF REQUIf�ED DIMENSIONS WITH ACCESSIBLE, REMOVABLE SCREW -ON COVERS. PROVIDE JUNCTION AND PULL BOXES` IN SPECIAL SIZES AND SHAPES DETERMINED IN FIELD WHERE NECESSARY. B. JUNCTION BOX COVERS SHALL BE ACCESSIBLE. DO NOT INSTALL JUNCTION BOXES ABOVE SUSPENDED CEILINGS EXCEPT WHERE CEILING IS REMOVABLE OR WHERE ACCESS PANEL IS PROVIDED. C. PULL BOXES SHALL BE SUPPORTED ADEQUATELY TO MAINTAIN SHAPE. LARGER BOXES SHALL HAVE STRUCTURAL STEEL BRACING WELDED INTO RIGID ASSEMBLY FORMED ADEQUATELY TO MAINTAIN ALIGNMENT IN SHIPMENT AND INSTALLATION. SECURE COVERS WITH CORROSION -RESISTANT SCREWS. 1. PULL BOXES EXPOSED TO RAIN OR IN WET LOCATIONS SHALL BE WEATHERPROOF. 2. PROVIDE CLAMPS, GRIDS AND OTHER APPURTENANCES TO SECURE CABLES WITHIN PULL BOX. NO CABLE SHALL BE UNSUPPORTED FOR MORE THAN 30". 3. PULL BOXES CONNECTED TO CONCEALED CONDUITS SHALL BE MOUNTED WITH COVERS FLUSH WITH FINISHED WALL OR CEILING. 2.4 WIRE AND CABLE A. PROVIDE SINGLE -CONDUCTOR ANNEALED COPPER WIRE AND CABLE WITH INSULATION RATED 600 V, OF SIZES SPECIFIE6 AND SCHEDULED ON DRAWINGS, FOR SECONDARY SERVICE, FEEDERS, BRANCH AND SYSTEM WIRING. B. METAL CLAD CABLE SHALL BE 600 V COPPER WITH FULL-SIZED INSULATED GROUND CONDUCTOR. USE IS RESTRICTED BY REQUIREMENTS OF PARAGRAPH ENTITLED WIRING METHODS IN PART 3 OF THIS SECTION. MINIMUM SIZE SHALL BE 12 -AWG UNLESS SPECIFIED OTHERWISE. C. WIRE 10 -AWG AND LARGER SHALL BE STRANDED; 12 -AWG AND SMALLER SHALL BE SOLID. WIRE AND CABLE SHALL HAVE THWN-THHN OR XHHW INSULATION. D. MOTOR CONTROL CIRCUITS AND SIGNAL WIRING MAY BE 14 AWG IF NEC REQUIREMENTS ARE MET. BRANCH CIRCUITS LONGER THAN 75' FOR 120 V AND 175' FOR 277 V SHALL BE AT LEAST 10 -AWG FROM PANEL TO LAST OUTLET. E. WIRING WITHIN LUMINAIRES AND OTHER HIGH-TEMPERATURE EQUIPMENT SHALL HAVE 150'C INSULATION AS REQUIRED BY NEC. F. MAKE SPLICES IN BRANCH CIRCUIT WIRING WITH UL -LISTED, SOLDERLESS CONNECTORS RATED 600 V OF SIZES AND TYPES REQUIRED BY MANUFACTURER'S RECOMMENDATIONS WITH TEMPERATURE RATINGS EQUAL TO THOSE OF WIRES. SPLICE CONNECTORS SHALL BE SCREW ON. INSULATE SPLICES WITH INTEGRAL COVERS OR WITH PLASTIC OR RUBBER FRICTION TAPE TO PRESERVE CHARACTERISTICS OF WIRE AND CABLE INSULATION. G. MAKE TERMINATIONS AND SPLICES FOR CONDUCTORS 6 -AWG AND LARGER WITH CORROSION RESISTANT HIGH CONDUCTIVITY PRESSURE INDENT, HEX SCREW OR BOLT -CLAMP CONNE6fiORS, WITH OR WITHOUT TONGUES, DESIGNED SPECIFICALLY FOR INTENDED SERVICE. CONNECTORS FOR CABLES 250 KCMIL AND LARGER SHALL HAVE TWO CLAMPING ELEMENTS OR COMPRESSION INDENTS. TERMINALS FOR BUS CONNECTIONS SHALL HAVE TWO BOLT HOLES. H. AMPACITY OF SPLICES AND CONNECTORS SHALL BE EQUAL TO THOSE OF ASSOCIATED WIRES AND CABLES. 2.5 COLOR CODING A. COLOR CODE SECONDARY SERVICE, FEEDERS AND BRANCH CIRCUIT CONDUCTORS AS FOLLOWS: 208Y 120 VOLT:CK 480Y 277 VOLT: WN PHASE B: RED PHASE B: ORANGE PHASE C: BLUE PHASE C: YELLOW NEUTRAL: WHITE NEUTRAL: GRAY GROUND: GREEN GROUND: GREEN ISO GROUND:GREEN W/ YELLOW STRIPE B. BRANCH CIRCUIT CONDUCTORS 12 -AWG AND 10 -AWG SHALL HAVE SOLID COLOR COMPOUND, SOLID COLOR COATING. NEUTRALS AND EQUIPMENT GROUNDS SHALL HAVE SOLID COMPOUND OR SOLID COLOR COATING (WHITE, GRAY AND GREEN). C. ACCEPTABLE MANUFACTURER FOR WIRE AND CABLE SHALL BE AS FOLLOWS: 1. AMERICAN INSULATED WIRE CORP.; A LEVITON COMPANY 2. SENATOR WIRE & CABLE COMPANY 3. SOUTHWIRE COMPANY 2.6 WIRE PULLING EQUIPMENT A. PROVIDE POLYETHYLENE ROPES FOR PULLING WIRE. B. PROVIDE FISH WIRES IN TELEPHONE CONDUITS AND OTHER EMPTY CONDUIT SYSTEMS REQUIRED, WITHOUT SPLICES AND WITH AMPLE EXPOSED LENGTHS AT EACH END. C. PROVIDE WIRE PULLING LUBRICANTS THAT MEET APPLICABLE UL REQUIREMENTS AS NECESSARY. 2.7 WIRING DEVICES RECEPTACLES A. CONVENIENCE RECEPTACLES STRAIGHT BLADE CONVENIENCE RECEPTACLE DEVICES SHALL BE HEAVY DUTY INDUSTRIAL OR DECORATIVE COMMERCIAL SPECIFICATION GRADE AS DIRECTED BY THE ARCHITECT AND SHALL AT A MINIMUM INCORPORATE THE FOLLOWING FEATURES AND BENEFITS. COLOR BY ARCHITECT. 1. RECEPTACLES, 20 A, 125V, 2 -POLE, 3 -WIRE, GROUNDING TYPE WITH SELF GROUNDING CLIP AND BACK AND SIDE WIRED. B. GFCI RECEPTACLES: STRAIGHT BLADE GFCI TYPE RECEPTACLE DEVICES SHALL BE TAMPER RESISTANT, WEATHER RESISTANT, FEED -THROUGH TYPE. COMPLY WITH NEMA WD 1, NEMA WD 6, UL 498, AND UL 943, CLASS A, GROUP I SOLID STATE SENSING AND SIGNALING WITH FIVE (�5) MILLI -AMPERE FAULT TRIP LEVEL AND INCLUDE INDICATOR LIGHT THAT IS LIGHTED WH N DEVICE IS TRIPPED AND SHALL AT A MINIMUM INCORPORATE THE FOLLOWING FEATURES AND BENEFITS. COLOR BY ARCHITECT. 1. DUPLEX GFCI RECEPTACLES, 20 A, 125V, 2 -POLE, 3 -WIRE, GROUNDING TYPE WITH SELF GROUNDING CLIP AND BACK AND SIDE WIRED SWITCHES A. AC SWITCHES: AC SWITCHES SHALL BE HEAVY DUTY INDUSTRIAL OR DECORATIVE COMMERCIAL SPECIFICATION GRADE AS DIRECTED BY THE ARCHITECT, SHALL COMPLY WITH NEMA WD1 AND U.L. 20 AND AT A MINIMUM INCORPORATE THE FOLLOWING FEATURES AND BENEFITS 1. AC TOGGLE SWITCHES 20A, 120/277 VOLT AC WITH GROUND SCREW AND SELF GROUNDING CLIP AND BACK AND SIDE WIRED. B. ACCEPTABLE MANUFACTURERS/DEVICE NUMBERS FOR RECEPTACLES AND SWITCHES: RECEPTACLES - INDUSTRIAL SPECIFICATION GRADE HUBBELL COOPER LEVITON CONVENIENCE HBL5362 5362 5362 RECEPTACLES (DECORATIVE) - COMMERCIAL SPECIFICATION GRADE HUBBELL STYLE LINE COOPER DECORATOR LEVITON DECORA CONVENIENCE DR20 6362 16662 RECEPTACLES - GFCI TYPE HUBBELL STYLE LINE COOPER DECORATOR LEVITON DECORA GFCI GFTR20 GF20 8598-W I:IiiyTiTlllQMMIX.�1l1b11L11L,I/_l�.ylXillyNl_��[1P►tel:7_lplmteIKe1Nmf7» HUBBELL COOPER LEVITON SINGLE POLE HBL1201 2221 1221-2 THREE-WAY HBL1203 2223 1223-2 FOUR-WAY HBL1204 2224 1224-2 AC SWITCHES (DECORATIVE) - COMMERCIAL SPECIFICATION GRADE ROCKER TYPE HUBBELL COOPER LEVITON SINGLE POLE DS120 DECB120 5621-2 THREE-WAY DS320 DECB320 5623-2 FOUR-WAY DS420 DECB420 5624-2 C. INSTALLATION 1. WIRING DEVICES AND WALL PLATES a. SINGLE AND COMBINATION TYPES TO MATCH CORRESPONDING WIRING DEVICES. i. SMOOTH HIGH -IMPACT THERMOPLASTIC MATERIAL FOR FINISHED SPACES: ii. GALVANIZED STEEL MATERIAL FOR UNFINISHED SPACES: iii. VOICE/DATA JACKS SHALL UTILIZE THE SAME TYPE OF PLATE USED FOR RECE TACLES iv. DEVICES PLATES SHALL BE BY THE SAME MANUFACTURER AS THE WIRING DEVICE. v. DEVICE/PLATE COLOR SELECTED BY ARCHITECT. 2. RECEPTACLE ORIENTATION: a. INSTALL GROUND PIN OF VERTICALLY MOUNTED RECEPTACLES UP AND ON HORIZONTALLY MOUNTED RECEPTACLES TO THE RIGHT. 3. DO NOT USE OVERSIZED OR EXTRA -DEEP PLATES. REPAIR WALL FINISHES AND REMOUNT OUTLET BOXES WHEN STANDARD DEVICE PLATES DO NOT FIT FLUSH OR DO NOT COVER ROUGH WALL OPENING. 4. ARRANGEMENT OF DEVICES: UNLESS OTHERWISE INDICATED, MOUNT FLUSH, WITH LONG DIMENSION VERTICAL GROUP ADJACENT SWITCHES UNDER A SINGLE, MULTI -GANG WALL PLATE. 2.8 WIRING DEVICE PLATES A. PROVIDE TYPE AND COLOR AS DIRECTED BY ARCHITECT. B. VOICE/DATA OUTLET PLATES SHALL BE SAME AS USED FOR RECEPTACLES. C. DEVICE PLATES SHALL BE BY MANUFACTURER OF WIRING DEVICES. D. OUTLETS SHALL BE FLUSH TO SURFACE. 2.9 LUMINAIRES A. LISTED EINL LUIM NIAIRE SCQHEDULE, ANDD ASOSPECIF ED, WIREDE AND ASS MBLED. WI PRNbE APPROVED ALIGNERS, CANOPIES HANGERS AND OTHER APPURTENANCES AS REQUIRED FOR A COMPLETE SYSTEM PER MANUFACTURERS INSTRUCTIONS AND N.E.C. REQUIREMENTS. B. REFER TO LUMINAIRE SCHEDULE FOR SPECIFIC LAMP AND BALLAST TYPE AND MANUFACTURER REQUIREMENTS. C. PROVIDE POLYESTER COVERS TO PROTECT FLUORESCENT LUMINAIRES WITH LOUVERS, BASKETS, OR LENSES DURING CONSTRUCTION. 2.11 PANELBOARDS A. MANUFACTURERS 1. CUTLER HAMMER 2. GENERAL ELECTRIC 3. SQUARE D 4. SEIMENS THE LISTING OF SPECIFIC MANUFACTURERS ABOVE DOES NOT IMPLY ACCEPTANCE OF THEIR PRODUCTS THAT DO NOT MEET THE SPECIFIED RATINGS, FEATURES AND FUNCTIONS. MANUFACTURERS LISTED ABOVE ARE NOT RELIEVED FROM MEETING THESE SPECIFICATIONS IN THEIR ENTIRETY. PRODUCTS IN COMPLIANCE WITH THE SPECIFICATION AND MANUFACTURED BY OTHERS NOT NAMED WILL BE CONSIDERED ONLY IF PRE -APPROVED BY THE ENGINEER TEN (10) DAYS PRIOR TO BID DATE. B. RATINGS 1. PANELBOARDS RATED 240V AC OR LESS SHALL HAVE SHORT-CIRCUIT RATINGS AS SHOWN ON THE DRAWINGS OR AS HEREIN SCHEDULED, BUT NOT LESS THAN 10,000 AMPERES RMS SYMMETRICAL. 2. PANELBOARDS RATED 480V AC OR LESS SHALL HAVE SHORT-CIRCUIT RATINGS AS SHOWN ON THE DRAWINGS OR AS HEREIN SCHEDULED, BUT NOT LESS THAN 14,000 AMPERES RMS SYMMETRICAL. 3. PANELBOARDS SHALL BE LABELED WITH A UL SHORT-CIRCUIT RATING. WHEN SERIES RATINGS ARE APPLIED WITH INTEGRAL OR REMOTE UPSTREAM DEVICES A LABEL OR MANUAL SHALL BE PROVIDED. IT SHALL STATE THE CONDITIONS OF NE UL SERIES RATINGS INCLUDING: a. SIZE AND TYPE OF UPSTREAM DEVICE b. UL RECOGNIZED BRANCH DEVICES THAT CAN BE USED c. UL SERIES SHORT CIRCUIT RATING. C. CONSTRUCTION 1. INTERIORS SHALL BE COMPLETELY FACTORY ASSEMBLED DEVICES. THEY SHALL BE DESIGNED SUCH THAT SWITCHING AND PROTECTIVE DEVICES CAN BE REPLACED WITHOUT DISTURBING ADJACENT UNITS AND WITHOUT REMOVING THE MAIN BUS CONNECTORS. 2. TRIMS FOR BRANCH CIRCUIT PANELBOARDS SHALL BE SUPPLIED WITH A HINGED DOOR OVER ALL CIRCUIT BREAKER HANDLES. DOORS IN PANELBOARD TRIMS SHALL NOT UNCOVER ANY LIVE PARTS. DOORS SHALL HAVE A SEMI FLUSH CYLINDER LOCK AND CATCH ASSEMBLY. DOORS OVER 48 INCHES IN HEIGHT SHALL HAVE AUXILIARY FASTENERS. 3. DISTRIBUTION PANELBOARD TRIMS SHALL COVER ALL LIVE PARTS. SWITCHING DEVICE HANDLES SHALL BE ACCESSIBLE. 4. SURFACE TRIMS SHALL BE SAME HEIGHT AND WIDTH AS BOX. FLUSH TRIMS SHALL OVERLAP THE BOX BY 3 4 OF AN INCH ON ALL SIDES. / 5. A DIRECTORY CARD WITH A CLEAR PLASTIC COVER SHALL BE SUPPLIED AND MOUNTED ON THE INSIDE OF EACH DOOR. 6. ALL LOCKS SHALL BE KEYED ALIKE. D. BUS 1. MAIN BUS BARS SHALL BE TIN-PLATED ALUMINUM SIZED IN ACCORDANCE WITH UL STANDARDS TO LIMIT TEMPERATURE RISE ON ANY CURRENT CARRYING PART TO A MAXIMUM OF 65 DEGREES C ABOVE AN AMBIENT OF 40 DEGREES C MAXIMUM. 2. A SYSTEM GROUND BUS SHALL BE INCLUDED IN ALL PANELS. 3. FULL-SIZE (100% -RATED) INSULATED NEUTRAL BARS SHALL BE INCLUDED FOR PANELBOARDS SHOWN WITH NEUTRAL. BUS BAR TAPS FOR PANELS WITH SINGLE -POLE BRANCHES SHALL BE ARRANGED FOR SEQUENCE PHASING OF THE BRANCH CIRCUIT DEVICES. NEUTRAL BUSING SHALL HAVE A SUITABLE LUG FOR EACH OUTGOING FEEDER AND/OR BRANCH CIRCUIT REQUIRING A NEUTRAL CONNECTION. E. BRANCH CIRCUIT PANELBOARDS 1. THE MINIMUM SHORT-CIRCUIT RATING FOR BRANCH CIRCUIT PANELBOARDS SHALL BE AS SPECIFIED HEREIN OR AS INDICATED ON THE DRAWINGS. PANELBOARDS SHALL BE FULLY RATED. 2. BOLT -ON TYPE, HEAVY-DUTY, QUICK -MAKE, QUICK -BREAK, SINGLE AND MULTI -POLE CIRCUIT BREAKERS OF THE TYPES SPECIFIED HEREIN, SHALL BE PROVIDED FOR EACH CIRCUIT WITH TOGGLE HANDLES THAT INDICATE WHEN UNIT HAS TRIPPED. 3. CIRCUIT BREAKERS SHALL BE THERMAL -MAGNETIC TYPE WITH COMMON TYPE HANDLE FOR ALL MULTIPLE POLE CIRCUIT BREAKERS. CIRCUIT BREAKERS SHALL BE MINIMUM 100 -AMPERE FRAME AND THROUGH 100 -AMPERE TRIP SIZES SHALL TAKE UP THE SAME POLE SPACING. CIRCUIT BREAKERS SHALL BE UL LISTED AS TYPE 'SWD' FOR LIGHTING CIRCUITS, AND UL LISTED AS TYPE 'HACR' FOR HEATING, AIR-CONDITIONING AND REFRIGERATING EQUIPMENT. a. CIRCUIT BREAKER HANDLE LOCKS SHALL BE PROVIDED FOR ALL CIRCUITS THAT SUPPLY EXIT SIGNS EMERGENCY LIGHTS ENERGY MANAGEMENT AND CONTROL SYSTEM (EMCS) PANELS AND FIRE ALARM PANELS. 4. BRANCH CIRCUIT BREAKERS SHALL HAVE A MINIMUM INTERRUPTING RATING OF 10,000 AMPERES SYMMETRICAL AT 240 VOLTS AND 14,000 AMPERES SYMMETRICAL AT 480 VOLTS. F. ENCLOSURE 1. ENCLOSURES SHALL BE AT LEAST 20 INCHES WIDE MADE FROM GALVANIZED STEEL. ROVIDE MINIMUM GUTTER SPACE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. WHERE FEEDER CABLES SUPPLYING THE MAINS OF A PANEL ARE CARRIED THROUGH ITS BOX TO SUPPLY OTHER ELECTRICAL EQUIPMENT, THE BOX SHALL BE SIZED TO INCLUDE THE ADDITIONAL REQUIRED WIRING SPACE. AT LEAST FOUR INTERIOR MOUNTING STUDS WITH ADJUSTABLE NUTS SHALL BE PROVIDED. 2. ENCLOSURES SHALL BE PROVIDED WITH BLANK ENDS. 3. EXTERIOR MOUNTED PANELBOARD SHALL BE NEMA 3R AND RATED FOR EXTERIOR APPLICATIONS G. SERVICE ENTRANCE LABEL 1. EQUIPMENT WITH MAIN SERVICE DISCONNECT SWITCHES) SHALL BE UL LABELED FOR USE AS SERVICE ENTRANCE EQUIPMENT. H. FUTURE DEVICES 1. PANELBOARDS SHALL BE FULLY PROVISIONED WITH ALL NECESSARY MOUNTING BRACKETS, BUS CONNECTIONS AND APPURTENANCES REQUIRED FOR INSTALLATION OF FUTURE DEVICES. I. ACCESSORY COMPONENTS AND FEATURES 1. PROVIDE ACCESSORY SET INCLUDING TOOLS AND MISCELLANEOUS ITEMS REQUIRED FOR OVERCURRENT PROTECTIVE DEVICE TEST, INSPECTION, MAINTENANCE AND OPERATION. J. NAMEPLATES 1. PROVIDE AN ENGRAVED NAMEPLATE FOR EACH PANEL SECTION. K. WARNING LABEL 1. PROVIDE ARC -FLASH HAZARD WARNING LABEL FOR EACH PANEL SECTION PER NATIONAL ELECTRIC CODE (N.E.C.) ARTICLE 110.16. L. FINISH 1. SURFACES OF THE TRIM ASSEMBLY SHALL BE PROPERLY CLEANED, PRIMED, AND A FINISH COAT OF GRAY ANSI 61 PAINT APPLIED. PART 3 - EXECUTION 3.1 TESTING, INSPECTION, AND CLEANING A. TEST WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE EQUIPMENT IS CONNECTED; DEMONSTRATE INSULATION RESISTANCE BY MEGGER TEST AS REQUIRED. INSULATION RESISTANCE BETWEEN CONDUCTORS AND GROUNDS FOR SECONDARY DISTRIBUTIONS SYSTEMS SHALL MEET NEC REQUIREMENTS. B. VERIFY AND CORRECT AS NECESSARY: VOLTAGES, TAP SETTINGS, TRIP SETTINGS AND PHASING ON EQUIPMENT FROM SECONDARY DISTRIBUTION SYSTEM TO POINTS OF USE. TEST SECONDARY VOLTAGES AT BUS IN MAIN SWITCHBOARD, AT PANELBOARDS, AND AT OTHER LOCATIONS ON DISTRIBUTION SYSTEMS AS NECESSARY. TEST SECONDARY VOLTAGES UNDER NO-LOAD AND FULL -LOAD CONDITIONS. C. TEST LUMINAIRES WITH SPECIFIED LAMPS IN PLACE FOR 10 HOURS. DO NOT OPERATE LAMPS OTHER THAN FOR TESTING BEFORE FINAL INSPECTION BY ARCHITECT. REPLACE LAMPS THAT FAIL WITHIN 90 DAYS AFTER ACCEPTANCE BY ARCHITECT. D. PROVIDE NECESSARY TESTING EQUIPMENT AND TESTING. E. FAILURE OR DEFECTS IN WORKMANSHIP OR MATERIALS REVEALED BY TESTS OR INSPECTION SHALL BE CORRECTED PROMPTLY AND RETESTED. REPLACE DEFECTIVE MATERIAL. F. CLEAN PANELS AND OTHER EQUIPMENT. PANELBOARD INTERIORS SHALL BE CLEANED AND VACUUMED. EQUIPMENT WITH DAMAGE TO PAINTED FINISH SHALL BE REPAIRED TO ARCHITECT'S SATISFACTION. 3.2 NAMEPLATES A. PROVIDE NAMEPLATES ON SWITCHBOARDS, PANELBOARDS, JUNCTION BOXES AND CABINETS, AND FOR SPECIAL PURPOSE SWITCHES, MOTOR DISCONNECT SWITCHES, REMOTE CONTROL STATIONS, STARTERS OR OTHER CONTROLS FURNISHED OR INSTALLED UNDER THIS SECTION. NAMEPLATES SHALL DESIGNATE EQUIPMENT CONTROLLED AND FUNCTION. 3.3 ACCESS AND ACCESS PANELS A. PROVIDE PROPER ACCESS TO MATERIAL OR EQUIPMENT THAT REQUIRE INSPECTION, REPLACEMENT, REPAIR OR SERVICE AND COORDINATE THEIR DELIVERY WITH THE INSTALLING TRADE. IF PROPER ACCESS CANNOT BE PROVIDED, CONFER WITH ARCHITECT AS TO BEST METHOD OF APPROACH TO MINIMIZE EFFECTS OF REDUCED ACCESS. B. ACCESS PANELS SHALL HAVE SAME FIRE RATING CLASSIFICATION AS SURFACE PENETRATED. C. PANELS SHALL BE AT LEAST 12" X 12"; ACCESS PANELS AT EQUIPMENT SHALL BE 18" X 18". 3.4 WIRING METHODS A. ALL RACEWAYS, CABLE ASSEMBLIES, BOXES, CABINETS, FITTINGS, ETC. SHALL BE SECURED AND SUPPORTED IN ALL ASSEMBLIES AS REQUIRED PER N.E.C. ARTICLE 300.11. B. INSTALL WIRE AND CABLE AS SPECIFIED AND AS APPROVED BY AUTHORITIES HAVING JURISDICTION. ALL CONDUITS OR RACEWAYS SHALL BE CONCEALED WHERE POSSIBLE, EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. PROVIDE STAND-OFF CLIPS WHERE CONDUITS ARE INSTALLED ON MASONRY WALLS. C. RUN CONCEALED CONDUIT IN AS DIRECT LINES AS POSSIBLE WITH MINIMUM NUMBER OF BENDS OF LONGEST POSSIBLE RADIUS. RUN CONDUIT PARALLEL TO OR AT RIGHT ANGLES TO BUILDING LINES TIGHT TO BUILDING STRUCTURE. D. CONDUIT RUNS SHALL BE MECHANICALLY AND ELECTRICALLY CONTINUOUS FROM SERVICE ENTRANCE TO OUTLETS. CONDUIT SHALL ENTER AND BE SECURED TO CABINET, JUNCTION BOX, PULL BOX OR OUTLET BOX WITH LOCKNUT OUTSIDE AND BUSHING INSIDE. E. ALL RACEWAY SHALL BE 3 4" TRADE SIZE MINIMUM, AS INDICATED ON THE DRAWINGS OR AS REQUIRED BY THE NE AND SHALL CONTAIN AN EQUIPMENT GROUNDING CONDUCTOR. PROVIDE INSERTS, HANGERS, ANCHORS AND STEEL SUPPORTS AS NECESSARY. • ; Integrated �� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc ``'ll",11,,111,11, °�``�P� s BFR �'A�°' �4� �O No. 11400468 = •'. '• =-o'� STATE OF ;I� I .., ,�� '' n, a 1.,2� F. INSTALL CONDUIT SYSTEMS COMPLETE BEFORE DRAWING IN CONDUCTORS. BLOW THROUGH AND SWAB AFTER PLASTER IS FINISHED AND DRY, AND BEFORE CONDUCTORS ARE INSTALLED. G. WIRE FROM POINT OF SERVICE CONNECTION TO RECEPTACLES, LUMINAIRES, DEVICES, EQUIPMENT, AND OTHER ELECTRICAL APPARATUS AS SHOWN ON DRAWINGS. PROVIDE SLACK WIRE FOR CONNECTIONS. H. CONDUCTORS 10 -AWG AND SMALLER IN BRANCH CIRCUIT PANELBOARDS, SIGNAL CABINETS, SIGNAL CONTROL BOARDS, SWITCHBOARDS AND MOTOR CONTROL CENTERS SHALL BE BUNDLED. CONDUCTORS LARGER THAN 10 -AWG IN SWITCHBOARDS, MOTOR CONTROL CENTERS, AND PULL BOXES SHALL BE CABLED IN INDIVIDUAL CIRCUITS. I. FOLLOW HOMERUN CIRCUIT NUMBERS SHOWN ON DRAWINGS TO CONNECT CIRCUITS TO PANELBOARDS. CONNECT EACH BRANCH CIRCUIT HOMERUN WITH TWO OR MORE CIRCUITS AND COMMON NEUTRAL TO CIRCUIT BREAKER OR SWITCH IN THREE -WIRE OR FOUR -WIRE BRANCH CIRCUIT PANELBOARD SO THAT NO TWO CIRCUITS ARE FED FROM SAME BUS. WHERE PANELBOARD CABINETS ARE RECESSED, PROVIDE CONDUITS WITH SUFFICIENT CAPACITY FOR FUTURE CONDUCTORS FOR SPARE BRANCH CIRCUIT PROTECTIVE DEVICES AND SPACES IN PANELBOARD; STUB UP CONCEALED TO JUNCTION BOX. PROVIDE EXTENSIONS ABOVE CEILING. J. ELECTRICAL METALLIC TUBING (EMT) MAY BE USED FOR INTERIOR APPLICATIONS ABOVE GRADE WHERE PERMITTED BY CODES FOR LUMINAIRE AND RECEPTACLE CIRCUITS TELEPHONE, INTER -COMMUNICATIONS, SIGNAL AND INSTRUMENTATION CIRCUITS, AND FOR CONTROL CIRCUITS. EMT MAY BE USED ABOVE HUNG CEILINGS, IN EQUIPMENT ROOMS, IN MECHANICAL AND ELECTRICAL CHASES AND CLOSETS, IN EXPOSED LOCATIONS ALONG CEILINGS OR WALLS ABOVE NORMAL TRAFFIC LEVEL AND WHERE NOT SUBJECT TO ACCIDENTAL DAMAGE OR ABUSE. K. INSTALL CONNECTORS AND COUPLINGS AS RECOMMENDED BY MANUFACTURERS. COMPRESSION FITTINGS SHALL BE USED IN AREAS SUBJECT TO MOISTURE. L. METAL CLAD CABLE (MC AS APPROVED BY LOCAL CODE FOR RECEPTACLE CIRCUITS IN SUSPENDED CEILINGS AND STUD WALL PARTITIONS. N. FLEXIBLE METAL CONDUIT (FMC) SHALL BE USED FOR CONNECTIONS TO ELECTRICAL EQUIPMENT AND TO EQUIPMENT FURNISHED UNDER DIVISIONS 14 AND 15 THAT ARE SUBJECT TO MOVEMENT AND VIBRATION. FMC SHALL BE LIMITED TO LENGTHS OF 6 FEET AND SHALL CONTAIN GROUNDING CONDUCTOR. 0. ALL LOW VOLTAGE CABLE NOT IN CONDUIT AND INSTALLED IN RETURN AIR PLENUM SHALL BE U.L. LISTED PLENUM TYPE CABLE. P. OPENINGS AROUND ELECTRICAL PENETRATIONS THROUGH FIRE RESISTANT RATED WALLS, PARTITIONS, FLOORS, OR CEILINGS SHALL BE FIRESTOPPED USING U.L. APPROVED METHODS PER MANUFACTURES GUIDELINES (HILTI FIRE STOP SYSTEMS OR 3M FIRE PROTECTION PRODUCTS) TO MAINTAIN THE FIRE RESISTANCE RATING OF STRUCTURE. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATINGS RE UIREMENTS TO BE MAINTAINED. Q 3.5 INSTALLATION OF LUMINAIRES A. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING CONSTRUCTION TYPES, HEIGHTS, CEILING SPACE CLEARANCES, ETC. WITH THE ARCHITECTURAL, MECHANICAL, PLUMBING, AND FIRE PROTECTION PLANS ELEVATIONS AND DETAILS. PROVIDE PROPER FRAMES ROUGH -IN KITS, TRIM RINGS, MOUNTING HARDWARE, N.E.C. REQUIRED ACCESS, ANCILLARY ACCRESSORIES, ETC. FOR A COMPLETE N.E.C. AND U.L. LISTED INSTALLATION PER ALL MANUFACTURER'S REQUIREMENTS. B. COORDINATE INSTALLATION OF ALL LUMINAIRES WITH ALL TRADES AND THE INSTALLATION OF CEILING MATERIALS AND SUSPENSION SYSTEMS PRIOR TO ANY ROUGH -INS. C. DO NOT INSTALL LUMINAIRES UNTIL WORK OF OTHER TRADES THAT MAY DAMAGE LUMINAIRES IS COMPLETED. D. INVESTIGATE LUMINAIRE LOCATIONS AND SUPPORTS TO ENSURE THAT NO INTERFERENCE EXISTS WITH HANGERS, DUCTS, SPRINKLERS, PIPES AND ALL OTHER EQUIPMENT. E. PROVIDE PROPER PLASTER FRAMES FOR LUMINAIRES RECESSED IN GYPSUM BOARD OR PLASTER CEILING. F. DO NOT SUSPEND OR SUPPORT LUMINAIRES OR SAFETY CHAINS FROM HUNG CEILING, CONDUIT OR DUCT. SUPPORT LUMINAIRES FROM STRUCTURAL BUILDING MEMBERS ONLY. G. FRAMING MEMBERS OF SUSPENDED CEILING SYSTEMS USED TO SUPPORT LUMINAIRES SHALL BE SECURELY FASTENED TO EACH OTHER AND SHALL BE SECURELY ATTACHED TO THE BUILDING STRUCTURE AT APPROPRIATE INTERVALS. LUMINAIRES SHALL BE SECURELY FASTENED TO THE CEILING FRAMING MEMBER BY MECHANICAL MEANS SUCH AS BOLTS, SCREWS, OR RIVETS. LISTED CLIPS IDENTIFIED FOR USE WITH THE TYPE OF CEILING FRAMING MEMBER() AND LUMINAIRES) SHALL ALSO BE PERMITTED PER N.E.C. 2008 ARTICLE 410.36 B . H. PROVIDE STRUT BELOW DUCTS WHERE LUMINAIRE LOCATIONS COINCIDE WITH DUCT RUNS. PROVIDE A COMPLETE THREADED ROD SYSTEM TO SUPPORT STRUT. I. PATCH ALL EXISTING SPRAY -ON FIREPROOFING DAMAGED DURING INSTALLATION. J. SUPPORT SURFACE -MOUNTED LUMINAIRES AT LEAST TWO CONCEALED POINTS TO PREVENT ROTATION. K. LOCATE CEILING AND WALL MOUNTED LUMINAIRES AS SHOWN ON ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS. 3.6 GROUNDING A. PROVIDE EQUIPMENT GROUNDING SYSTEM AS SHOWN ON DRAWINGS. EQUIPMENT GROUNDING SYSTEM SHALL BE DESIGNED SO METALLIC STRUCTURES, ENCLOSURES, RACEWAYS, JUNCTION BOXES, OUTLET BOXES, CABINETS, MACHINE FRAMES, PORTABLE EQUIPMENT AND OTHER CONDUCTIVE ITEMS IN CLOSE PROXIMITY WITH ELECTRICAL CIRCUITS OPERATE CONTINUOUSLY AT GROUND POTENTIAL AND PROVIDE LOW IMPEDANCE PATH FOR POSSIBLE GROUND FAULT CURRENTS. B. SYSTEM SHALL MEET NEC REQUIREMENTS, MODIFIED AS SHOWN ON DRAWINGS AND AS SPECIFIED. C. PROVIDE SEPARATE GREEN INSULATED E UIPMENT GROUNDING CONDUCTOR FOR EACH Q BRANCH CIRCUIT. INSTALL GROUNDING CONDUCTOR IN COMMON CONDUIT WITH RELATED PHASE OR NEUTRAL CONDUCTORS, OR BOTH. PARALLEL FEEDERS INSTALLED IN MORE THAN ONE RACEWAY SHALL HAVE INDIVIDUAL FULL SIZE GREEN INSULATED EQUIPMENT GROUND CONDUCTORS. D. DETERMINE NUMBERS AND SIZES OF SCREW TERMINALS FOR EQUIPMENT GROUNDING BARS IN PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT. PROVIDE SCREW TERMINALS FOR ACTIVE CIRCUITS, SPARES AND SPACES. E. PROVIDE GREEN INSULATED GROUNDING CONDUCTOR IN NONMETALLIC CONDUITS OR DUCTS UNLESS SPECIFIED OTHERWISE. 3.7 TELECOMMUNICATIONS CONDUIT SYSTEM A. PROVIDE SYSTEM OF EMPTY CONDUIT, OUTLETS AND MOUNTING BOARDS, AS SPECIFIED AND AS SHOWN ON DRAWINGS. B. NYLON PULL -IN WIRE SHALL BE INSTALLED IN TELECOMMUNICATIONS CONDUITS FOR USE BY OWNER. HELLYER LEWIS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 1 2th St. PhiIa., PA 1 91 07 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual® INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawn by: M E B Checked by: A,JM Approved by: A,JM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Electrical Specifications No. E-8.04 RELEASED IFCR CONSTRUCTION Subject to uumpdiianice with alll regulatimna of State and Uncal Endes ICitp of Caimal DATE: 02/23/18 Nick Mishler FIRE PROTECTION SPECIFICATIONS 1. GENERAL PROVISIONS A. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, ALTERNATES, ADDENDA'S', AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. CONTRACTORS AND SUBCONTRACTORS SHALL EXAMINE SAME AS WELL AS OTHER DIVISIONS OF THE SPECIFICATIONS WHICH AFFECT WORK UNDER THIS DIVISION. B. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, SERVICES, AND SHALL PERFORM ALL WORK COMPLETE AND IN STRICT ACCORDANCE WITH THIS SPECIFICATION AND APPLICABLE DRAWINGS. C. THIS CONTRACTOR IS INSTRUCTED TO READ CAREFULLY THE SPECIFICATIONS FOR ALL PARTS OF THE WORK, WHICH INCLUDE THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION, CIVIL, STRUCTURAL AND ALL OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS THAT ARE PART OF THE CONTRACT DOCUMENTS. D. ALL ITEMS OF LABOR, MATERIAL AND EQUIPMENT NOT SPECIFICALLY MENTIONED HEREIN OR SHOWN ON PLANS, BUT INCIDENTAL TO, OR REQUIRED FOR THE COMPLETE INSTALLATION AND PROPER OPERATION OF THE WORK, SHALL BE FURNISHED AS IF CALLED FOR IN DETAIL BY THE SPECIFICATIONS OR DRAWINGS. E. AS USED IN THIS SPECIFICATION, "PROVIDE" MEANS "FURNISH AND INSTALL". "FURNISH" MEANS "TO PURCHASE AND DELIVER TO THE PROJECT SITE COMPLETE WITH EVERY NECESSARY APPURTENANCE AND SUPPORT," AND "INSTALL" MEANS "TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND PERFORM EVERY OPERATION NECESSARY FOR PROPER INSTALLATION PER CODES AND MANUFACTURERS REQUIREMENTS, TO ESTABLISH SECURE MOUNTING AND CORRECT OPERATION AT THE PROPER LOCATION IN THE PROJECT. 2. PERMITS, CODES, INSPECTIONS, AND TESTS A. THE FIRE PROTECTION CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED FOR THE PROSECUTION OF FIRE PROTECTION WORK. ALL PERMITS AND CERTIFICATES OF INSPECTION AND APPROVAL SIGNED BY THE CONTROLLING BUILDING DEPARTMENT SHALL BECOME PROPERTY OF THE OWNER. B. THE FIRE PROTECTION SYSTEM SHALL BE INSTALLED PER THE REQUIREMENTS OF NFPA 13 AND THE LOCAL AUTHORITIES HAVING JURISDICTION. C. DRAWINGS INDICATE THE MINIMUM DESIGN REQUIREMENTS. NATIONAL, STATE, AND LOCAL CODES SHALL BE FOLLOWED. COMPLY WITH THE LATEST EDITIONS OF THE LOCAL GOVERNING PLUMBING CODE, LOCAL GOVERNING MECHANICAL CODE, AND NFPA STANDARDS. THE CONTRACTOR SHALL INCLUDE THE COST OF SATISFYING SUCH CODES AND STANDARDS IN HIS BID. FOLLOWING COMPLETION OF THE FIRE PROTECTION WORK, FURNISH TO THE OWNER, IN DUPLICATE, CERTIFICATES OF INSPECTION AND APPROVAL BY REGULATORY AGENCIES HAVING JURISDICTION. (1) DEMONSTRATE TO THE OWNER'S SATISFACTION THE PROPER OPERATION OF EACH OF THE SYSTEMS COMPRISING THIS CONTRACT BEFORE FINAL PAYMENT. (2) IMMEDIATELY CORRECT ANY WORK FOUND AT VARIANCE WITH THESE SPECIFICATIONS, THE NATIONAL, STATE, AND LOCAL CODES, AND REQUIREMENTS OF GOVERNING REGULATORY AGENCIES. 3. VISIT TO THE SITE A. THE CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH ALL CONDITIONS AFFECTING THE WORK. THE SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE KNOWLEDGE OF ALL SUCH CONDITIONS AND NO ADDITIONAL COMPENSATION SHALL BE ALLOWED WHERE EXTRA LABOR OR MATERIALS ARE REQUIRED BECAUSE OF IGNORANCE OF THESE CONDITIONS. 4. PROTECTION A. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION FROM DIRT AND WATER DURING CONSTRUCTION NECESSITATED BY FIRE PROTECTION WORK. PROTECTION METHODS ARE SUBJECT TO APPROVAL BY THE ARCHITECT. 5. EQUIPMENT AND MATERIALS A. ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND SHALL CONFORM TO UNDERWRITERS' LABORATORIES STANDARDS, WHERE APPLICABLE. WHERE SPECIFICATIONS DESCRIBE, OR PLANS SHOW, MATERIALS OR EQUIPMENT OF HIGHER QUALITY THAN REQUIRED BY CODE AND LOCAL RULING, THE DRAWINGS AND SPECIFICATIONS SHALL GOVERN THE QUALITY OF THE MATERIAL OR EQUIPMENT. B. THE CONTRACTOR SHALL SUBMIT PROOF, IF REQUESTED BY THE OWNER THAT THE MATERIALS, APPLIANCES, EQUIPMENT OR DEVICES FURNISHED AND INSTALLED UNDER THIS CONTRACT, MEET THE REQUIREMENTS OF THE UNDERWRITERS' LABORATORIES, INC., AS REGARDS FIRE AND CASUALTY HAZARDS. THE LABEL OF OR LISTING BY THE UNDERWRITERS' LABORATORIES, INC. WILL BE ACCEPTED AS CONFORMING WITH THIS REQUIREMENT. IN LIEU OF THE LABEL OR LISTING, THE CONTRACTOR MAY SUBMIT INDEPENDENT PROOF SATISFACTORY TO THE ARCHITECT THAT THE MATERIALS, APPLIANCES OR DEVICES CONFORM TO THE PUBLISHED STANDARDS, INCLUDING METHODS OF TEST OF THE UNDERWRITERS' LABORATORIES, INC. UNDERWRITERS' LABORATORIES, INC. AND ITS PUBLICATIONS WILL BE REFERRED TO HEREINAFTER BY THE ABBREVIATION UL, WITH OR WITHOUT ADDITIONAL IDENTIFYING SYMBOLS. 6. GUARANTEE A. THE FIRE PROTECTION CONTRACTOR SHALL GUARANTEE FOR A PERIOD OF ONE YEAR THAT ALL WORK AND EQUIPMENT WILL REMAIN FREE FROM ALL DEFECTS IN WORKMANSHIP AND MATERIALS, AND THAT IT WILL COMPLY WITH ALL THE SPECIFIC REQUIREMENTS OF THE SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS GOVERNING THE WORK. B. ALL WORK FOUND BY THE ENGINEER TO BE DEFECTIVE WILL BE REPLACED WITH NEW WORK MEETING ALL THE REQUIREMENTS OF THE CONTRACT. THE FIRE PROTECTION CONTRACTOR WILL BEAR ALL COSTS OF SUPPLYING SUCH NEW WORK, AND INSTALLING AND FINISHING SAME, AND WILL ASSUME ALL COSTS FOR REPLACING OTHER WORK DAMAGED BY THE REMOVAL AND REPLACEMENT OF ANY OF THE WORK. THE FIRE PROTECTION CONTRACTOR WILL BEAR ALL COSTS FOR FREIGHT, DRAYAGE AND DEMURRAGE, AND ALL LABOR IN CONNECTION THEREWITH. 7. CUTTING, PATCHING, FIRESTOPPING AND PAINTING A. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING ALL HOLES REQUIRED FOR INSTALLATION OF FIRE PROTECTION WORK. HOLES SHALL BE CUT IN A NEAT MANNER SATISFACTORY TO THE ARCHITECT. B. UNLESS NOTED OTHERWISE, ALL HOLES OR DAMAGE CAUSED BY THE REMOVAL OF EXISTING WORK OR THE INSTALLATION OF NEW WORK SHALL BE PROPERLY PATCHED BY THIS CONTRACTOR. HOLES SHALL BE NEATLY PATCHED AND PAINTED WITH SUITABLE MATERIAL TO MATCH EXISTING SURFACES. HOLES THROUGH FLOORS OR FIRE WALLS SHALL BE SEALED WITH THE APPROPRIATE INTUMESCENT CAULK, PUTTY, STRIP OR SHEET TYPE FIRE BARRIER PRODUCT. C. FIRESTOP SYSTEM (REQUIRED FIRESTOPPING MATERIALS) SHALL BE DETERMINED BY THE WALL OR FLOOR/CEILING ASSEMBLY AND PENETRATION TYPE AND SHALL BE UL LISTED AND TESTED IN ACCORDANCE WITH ASTM E814. FIRE RATING OF THE FIRESTOP SYSTEM SHALL BE EQUIVALENT TO THE ASSEMBLY WHICH IS PENETRATED. D. ACCEPTABLE FIRE BARRIER PRODUCTS: HILTI "FS -ONE", NELSON "FLAMESEAL" OR APPROVED EQUAL AS MANUFACTURED BY 3M. 8. CLEANING AND PAINTING A. CLEAN NEW PIPING AFTER WORK IS COMPLETE TO REMOVE PIPE DOPE, LOOSE MILL SCALE AND OTHER EXTRANEOUS MATERIALS. B. TOUCH UP AND REPAIR ANY DAMAGED FACTORY FINISHES ON EQUIPMENT AND MATERIALS FURNISHED. OTHER PAINTING WILL BE DONE UNDER THE PAINTING DIVISION OF THE SPECIFICATIONS. 10. COORDINATION AND CONDUCT OF WORK A. FIRE PROTECTION DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT, APPROXIMATE SIZES, GENERAL LOCATIONS OF EQUIPMENT, SPRINKLER HEADS, AND PIPING. VERIFY DIMENSIONS IN FIELD; ADJUST TO MANUFACTURER'S SHOP DRAWINGS. DO NOT SCALE DRAWINGS. B. ALL REQUESTS FOR INFORMATION SUPPLEMENTAL TO THE CONSTRUCTION DOCUMENTS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT FOR DISTRIBUTION TO THE APPROPRIATE PARTY(S). C. DRAWINGS AND SPECIFICATIONS ARE TO BE CONSIDERED AS SUPPLEMENTING EACH OTHER. WORK SPECIFIED BUT NOT SHOWN, OR SHOWN BUT NOT SPECIFIED, SHALL BE PERFORMED OR FURNISHED AS THOUGH MENTIONED IN BOTH SPECIFICATIONS AND DRAWINGS. D. ARCHITECTURAL AND STRUCTURAL DRAWINGS SUPERSEDE FIRE PROTECTION DRAWINGS. DETERMINE THAT WORK OF THIS DIVISION CAN BE ACCOMMODATED WITHIN SPACES PROVIDED. NOTIFY ARCHITECT OF ANY INTERFERENCES BEFORE STARTING INSTALLATION. E. DETERMINE SIZES, LOCATIONS FOR CHASES AND OPENINGS NECESSARY FOR INSTALLATION OF PLUMBING AND FIRE PROTECTION WORK. COOPERATE WITH OTHER TRADES IN SETTING SLEEVES, INSERTS AND HANGERS. F. COORDINATE THIS WORK WITH ALL TRADES. ARRANGE OPERATIONS SO AS NOT TO DELAY INSTALLATION OF COMPLETION OF ANY PARTS OF INTERRELATED WORK SO THAT CONSTRUCTION MAY PROCEED ON SCHEDULE. G. COOPERATE WITH ALL TRADES IN PREPARING INTERFERENCE DRAWINGS FOR AREAS WHERE THERE IS POSSIBLE CONFLICT BETWEEN TRADES. EXACT LOCATION OF PIPES, AND EQUIPMENT SHALL BE BASED ON FIELD MEASUREMENTS WITH FINAL ARRANGEMENT DETERMINED BY INTRA -TRADE AGREEMENTS SUBJECT TO ARCHITECT'S APPROVAL. H. ARCHITECT RESERVES THE RIGHT TO MAKE REASONABLE CHANGES IN INDICATED LOCATIONS WITHOUT EXTRA COST TO THE OWNER. I. ALL WORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER BY FIRST-CLASS MECHANICS. THE CONTRACTOR SHALL PROVIDE ADEQUATE AND COMPETENT SUPERVISION OF THE JOB AS REQUIRED. J. PIPING AND EQUIPMENT SHALL BE ARRANGED SUBSTANTIALLY AS INDICATED. ANY CHANGE RESULTING IN A SAVINGS IN LABOR OR MATERIAL SHALL BE MADE ONLY IN ACCORDANCE WITH A CONTRACT CHANGE ORDER. DEVIATIONS SHALL BE MADE ONLY WHERE NECESSARY TO AVOID INTERFERENCES AND ONLY AFTER DRAWINGS SHOWING THE PROPOSED DEVIATIONS HAVE BEEN SUBMITTED TO AND APPROVED BY THE ARCHITECT. K. COORDINATE ALL SHUTDOWNS OF FIRE PROTECTION SYSTEM IN ADVANCE WITH THE OWNER. 11. SUBMITTALS A. PROVIDE A MINIMUM OF SIX (6) SUBMITTAL DRAWINGS FOR EQUIPMENT, SPRINKLER HEADS, FIRE PROTECTION HYDRAULIC CALCULATIONS, AND ALL OTHER SPECIFIED COMPONENTS FOR APPROVAL BY THE ARCHITECT AND ENGINEER. B. WHERE ONLY ONE MAKE OF EQUIPMENT IS NAMED, IT SHALL BE PROVIDED AS SPECIFIED. C. VERBAL REQUESTS OF APPROVALS FOR ANY SUBSTITUTION WILL NOT BE BINDING ON THE ARCHITECT AND OWNER. D. THIS CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR ALL COSTS FOR REDESIGN CHANGES NECESSARY BY ALL TRADES TO ACCOMMODATE THE USE OF EQUIPMENT NOT SPECIFIED ON PROJECT DOCUMENTS. E. BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVES. DRAWINGS AND SPECIFICATIONS ARE BASED ON THE PRODUCTS SPECIFIED BY TYPE, MODEL, AND SIZE AND THUS ESTABLISH MINIMUM QUALITIES, WHICH SUBSTITUTES MUST MEET TO QUALIFY FOR REVIEW. F. SHOULD THE CONTRACTOR PROPOSE TO FURNISH MATERIALS, EQUIPMENT, AND DEVICES, OTHER THAN THOSE SPECIFIED AND LISTED, THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR SUBSTITUTIONS, TO THE ENGINEER, AT LEAST FOURTEEN (14) CALENDAR DAYS PRIOR TO BID OPENING. THE REQUEST SHALL BE AN ALTERNATE TO THE ORIGINAL BID AND SHALL INCLUDE AND BE ACCOMPANIED WITH COMPLETE SPECIFICATIONS CUT SHEET SUBMITTAL AS OUTLINED IN SECTION 11.A OF THIS SPECIFICATION SECTION, COMPLETE WITH DESCRIPTIVE (MANUFACTURER, BRAND NAME, CATALOG NUMBER, ETC.) AND TECHNICAL DATA FOR ALL ITEMS. INDICATE ANY ADDITIONS OR DEDUCTIONS TO THE CONTRACT PRICE WITH THE SUBSTITUTION SUBMITTAL AND ON THE BID FORM. G. ACCEPTANCE OR REJECTION OF THE PROPOSED SUBSTITUTIONS SHALL BE SUBJECT TO APPROVAL OF THE ARCHITECT AND ENGINEER. IF REQUESTED, THE CONTRACTOR SHALL SUBMIT INSPECTION SAMPLES OF BOTH THE SPECIFIED AND THE PROPOSED SUBSTITUTE ITEMS. H. IF ANY SUBSTITUTIONS ARE APPROVED, AN ADDENDUM LISTING THE APPROVED ITEMS) WILL BE ISSUED TO ALL BIDDING CONTRACTORS PRIOR TO THE BID DATE. I. IN ALL CASES WHERE SUBSTITUTIONS ARE PERMITTED, THE CONTRACTOR SHALL BEAR ANY EXTRA COST OF EVALUATING THE EQUALITY OF THE MATERIAL AND EQUIPMENT TO BE INSTALLED. J. WHERE ONLY ONE MAKE IS NAMED IN THE SPECIFICATIONS OR ON THE DRAWINGS, IT SHALL BE PROVIDED. K. VERBAL REQUESTS OR APPROVALS SHALL NOT BE BINDING ON THE ENGINEER OR OWNER. 12. EQUIPMENT AND PIPING IDENTIFICATION A. LABEL ALL PIPING SYSTEMS WITH PIPE MARKERS INSTALLED ADJACENT TO VALVES, WHERE PIPES PASS THROUGH WALLS OR FLOORS, NEAR ALL BRANCHES AND CHANGES OF DIRECTION, AT 20 FEET INTERVALS ON STRAIGHT RUNS OF PIPE, AND AT ACCESS DOOR LOCATIONS. ALL PIPE MARKERS SHALL CONFORM TO ANSI A13.1 "SCHEME FOR THE IDENTIFICATION OF PIPING SYSTEMS". B. THE CONTRACTOR SHALL FURNISH AND INSTALL A SYSTEM OF NAMEPLATES DESIGNED TO IDENTIFY EACH PIECE OF EQUIPMENT. (1) NAMEPLATE LETTER AND NUMBERS SHALL MATCH EQUIPMENT DESIGNATION AS INDICATED ON THE DRAWINGS. (2) NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH BLACK SURFACE AND WHITE CORE. USE 1/16" THICK MATERIAL FOR PLATES UP TO 2" BY 4". FOR LARGER SIZES USE 1/8" THICK. LETTERS AND NUMBERS SHALL BE A MINIMUM OF 1/2" HIGH. (1) FASTEN NAMEPLATES TO ALL EQUIPMENT BY THE USE OF STAINLESS STEEL SHEET METAL SCREWS. 13. AS -BUILT DRAWINGS A. AS WORK PROGRESSES, RECORD ON A SET OF "AS -BUILT" PRINTS ANY DEVIATIONS FROM DESIGN DRAWINGS. DELIVER TO THE OWNER BEFORE SUBMITTING REQUEST FOR FINAL PAYMENT. THE "AS -BUILT" PRINTS SHALL BE AN ACCURATE DEPICTION OF THE PROJECT AS COMPLETED. 14. OPERATING AND MAINTENANCE MANUALS A. PROVIDE TO OWNER, AT PROJECT TURNOVER, THREE (3) HARDBOUND COPIES OF OPERATING AND MAINTENANCE MANUALS FOR ALL EQUIPMENT AND SYSTEMS INSTALLED. MANUALS SHALL INCLUDE ALL RELEVANT INFORMATION NEEDED FOR DAY-TO-DAY OPERATION AND MANAGEMENT OF EACH SYSTEM, AS WELL AS EQUIPMENT MAINTENANCE INFORMATION REQUIRED TO SUPPORT THE MAINTENANCE PROGRAM. 11. SUBMITTALS A. PROVIDE A MINIMUM OF SIX (6) SUBMITTAL DRAWINGS FOR EQUIPMENT, SPRINKLER HEADS, FIRE PROTECTION HYDRAULIC CALCULATIONS, AND ALL OTHER SPECIFIED COMPONENTS FOR APPROVAL BY THE ARCHITECT AND ENGINEER. B. WHERE ONLY ONE MAKE OF EQUIPMENT IS NAMED, IT SHALL BE PROVIDED AS SPECIFIED. C. VERBAL REQUESTS OF APPROVALS FOR ANY SUBSTITUTION WILL NOT BE BINDING ON THE ARCHITECT AND OWNER. D. THIS CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR ALL COSTS FOR REDESIGN CHANGES NECESSARY BY ALL TRADES TO ACCOMMODATE THE USE OF EQUIPMENT NOT SPECIFIED ON PROJECT DOCUMENTS. E. BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVES. DRAWINGS AND SPECIFICATIONS ARE BASED ON THE PRODUCTS SPECIFIED BY TYPE, MODEL, AND SIZE AND THUS ESTABLISH MINIMUM QUALITIES, WHICH SUBSTITUTES MUST MEET TO QUALIFY FOR REVIEW. F. SHOULD THE CONTRACTOR PROPOSE TO FURNISH MATERIALS, EQUIPMENT, AND DEVICES, OTHER THAN THOSE SPECIFIED AND LISTED, THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR SUBSTITUTIONS, TO THE ENGINEER, AT LEAST FOURTEEN (14) CALENDAR DAYS PRIOR TO BID OPENING. THE REQUEST SHALL BE AN ALTERNATE TO THE ORIGINAL BID AND SHALL INCLUDE AND BE ACCOMPANIED WITH COMPLETE SPECIFICATIONS CUT SHEET SUBMITTAL AS OUTLINED IN SECTION 11.A OF THIS SPECIFICATION SECTION, COMPLETE WITH DESCRIPTIVE (MANUFACTURER, BRAND NAME, CATALOG NUMBER, ETC.) AND TECHNICAL DATA FOR ALL ITEMS. INDICATE ANY ADDITIONS OR DEDUCTIONS TO THE CONTRACT PRICE WITH THE SUBSTITUTION SUBMITTAL AND ON THE BID FORM. G. ACCEPTANCE OR REJECTION OF THE PROPOSED SUBSTITUTIONS SHALL BE SUBJECT TO APPROVAL OF THE ARCHITECT AND ENGINEER. IF REQUESTED, THE CONTRACTOR SHALL SUBMIT INSPECTION SAMPLES OF BOTH THE SPECIFIED AND THE PROPOSED SUBSTITUTE ITEMS. H. IF ANY SUBSTITUTIONS ARE APPROVED, AN ADDENDUM LISTING THE APPROVED ITEMS) WILL BE ISSUED TO ALL BIDDING CONTRACTORS PRIOR TO THE BID DATE. I. IN ALL CASES WHERE SUBSTITUTIONS ARE PERMITTED, THE CONTRACTOR SHALL BEAR ANY EXTRA COST OF EVALUATING THE EQUALITY OF THE MATERIAL AND EQUIPMENT TO BE INSTALLED. J. WHERE ONLY ONE MAKE IS NAMED IN THE SPECIFICATIONS OR ON THE DRAWINGS, IT SHALL BE PROVIDED. K. VERBAL REQUESTS OR APPROVALS SHALL NOT BE BINDING ON THE ENGINEER OR OWNER. 12. EQUIPMENT AND PIPING IDENTIFICATION A. LABEL ALL PIPING SYSTEMS WITH PIPE MARKERS INSTALLED ADJACENT TO VALVES, WHERE PIPES PASS THROUGH WALLS OR FLOORS, NEAR ALL BRANCHES AND CHANGES OF DIRECTION, AT 20 FEET INTERVALS ON STRAIGHT RUNS OF PIPE, AND AT ACCESS DOOR LOCATIONS. ALL PIPE MARKERS SHALL CONFORM TO ANSI A13.1 "SCHEME FOR THE IDENTIFICATION OF PIPING SYSTEMS'. B. THE CONTRACTOR SHALL FURNISH AND INSTALL A SYSTEM OF NAMEPLATES DESIGNED TO IDENTIFY EACH PIECE OF EQUIPMENT. (1) NAMEPLATE LETTER AND NUMBERS SHALL MATCH EQUIPMENT DESIGNATION AS INDICATED ON THE DRAWINGS. (2) NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH BLACK SURFACE AND WHITE CORE. USE 1/16" THICK MATERIAL FOR PLATES UP TO 2" BY 4". FOR LARGER SIZES USE 1/8" THICK. LETTERS AND NUMBERS SHALL BE A MINIMUM OF 1/2" HIGH. (1) FASTEN NAMEPLATES TO ALL EQUIPMENT BY THE USE OF STAINLESS STEEL SHEET METAL SCREWS. 13. AS -BUILT DRAWINGS A. AS WORK PROGRESSES, RECORD ON A SET OF "AS -BUILT" PRINTS ANY DEVIATIONS FROM DESIGN DRAWINGS. DELIVER TO THE OWNER BEFORE SUBMITTING REQUEST FOR FINAL PAYMENT. THE "AS -BUILT" PRINTS SHALL BE AN ACCURATE DEPICTION OF THE PROJECT AS COMPLETED. 14. OPERATING AND MAINTENANCE MANUALS A. PROVIDE TO OWNER, AT PROJECT TURNOVER, THREE (3) HARDBOUND COPIES OF OPERATING AND MAINTENANCE MANUALS FOR ALL EQUIPMENT AND SYSTEMS INSTALLED. MANUALS SHALL INCLUDE ALL RELEVANT INFORMATION NEEDED FOR DAY-TO-DAY OPERATION AND MANAGEMENT OF EACH SYSTEM, AS WELL AS EQUIPMENT MAINTENANCE INFORMATION REQUIRED TO SUPPORT THE MAINTENANCE PROGRAM. 15. OPERATING INSTRUCTIONS A. PROVIDE TO OWNER AFTER ALL EQUIPMENT IS IN OPERATION AND AT AN AGREEABLE TIME, INSTRUCTIONS FOR THE PURPOSE OF TRAINING OWNER'S PERSONNEL IN ALL PHASES OF OPERATION AND MAINTENANCE OF EQUIPMENT AND SYSTEMS. SCHEDULE TRAINING WITH OWNER, PROVIDE AT LEAST SEVEN DAYS PRIOR NOTICE. PROVIDE THIS TRAINING TO ALL PERSONNEL AND ON ALL SHIFTS. 16. FIRE PROTECTION A. GENERAL (1) FURNISH ALL LABOR, CONSTRUCTION EQUIPMENT AND MATERIALS NECESSARY FOR THE COMPLETE INSTALLATION OF THE FIRE PROTECTION SYSTEM AS INDICATED. ALL WORK SHALL BE IN STRICT COMPLIANCE WITH ALL GOVERNING STATE AND LOCAL CODE REQUIREMENTS, IN FULL CONFORMITY WITH THE BEST CURRENT TRADE PRACTICES AND SUBJECT TO APPROVAL OF THE ARCHITECT OR HIS REPRESENTATIVE. (2) ALL WORK DETAILS NOT COVERED IN THESE SPECIFICATIONS SHALL BE GOVERNED BY THE REQUIREMENTS OF THE LATEST EDITION OF NFPA-13. (3) SUPPORT ALL SPRINKLER PIPING PER NFPA 13 REQUIREMENTS. (4) PIPE BENDING IS NOT ACCEPTABLE. (5) ALL FIRE PROTECTION PIPING SYSTEMS MUST BE COMPLETELY DRAINABLE. B. DESIGN AND INSTALLATION REQUIREMENTS (1) PREPARE SHOP DRAWINGS AND HYDRAULIC CALCULATIONS IN ACCORDANCE WITH NFPA REQUIREMENTS. SUBMIT DRAWINGS TO LOCAL GOVERNMENT AGENCIES AND OWNER'S INSURANCE UNDERWRITER FOR APPROVAL. AFTER THE ABOVE AND PRIOR TO CONSTRUCTION, SUBMIT THE DOCUMENTS TO THE ARCHITECT AND ENGINEER FOR REVIEW. (1)1) THE CONTRACTOR SHALL ESTABLISH ACTUAL AVAILABILITY OF THE WATER FROM HISTORICAL DATA OR BY PERFORMING A FLOW TEST. (1)2) VERIFY HAZARD OCCUPANCY CLASSIFICATION REQUIREMENT WITH THE OWNER. (2) CONTRACTOR SHALL BE LICENSED BY ALL STATE AND LOCAL AUTHORITIES. (3) INSTALL U.L. OR F.M. APPROVED SPRINKLERS AS REQUIRED FOR COVERAGE. ALL SPRINKLERS SHALL BE NEW AND CENTERED IN CEILING TILE WHERE POSSIBLE. (4) PROVIDE SPRINKLER HEADS TO MATCH EXISTING HEADS INSTALLED IN ADJACENT AREAS. TYPE AND MANUFACTURER SHALL BE APPROVED BY THE OWNER. (1) COORDINATE SHUTDOWN OF THE EXISTING SPRINKLER SYSTEM WITH THE OWNER. (2) FIRE PROTECTION PIPING SHALL BE TESTED WITH WATER AT A PRESSURE OF 200 PSI FOR 2 HOURS. C. FIRE PROTECTION EQUIPMENT AND MATERIALS (1) PIPE AND FITTINGS a. FIRE PROTECTION PIPING, SHALL BE WELDED OR SEAMLESS BLACK STEEL AS SCHEDULED IN NFPA, WITH THREADED JOINTS. b. FITTINGS SHALL BE MALLEABLE IRON, THREADED TYPE, AS SCHEDULED IN NFPA. (1) SPRINKLER HEADS a. SPRINKLER HEADS SHALL BE UL LISTED AND FM APPROVED, MEETING NFPA REQUIREMENTS. b. TEMPERATURE RATING OF HEADS SHALL BE 165 DEGREES FAHRENHEIT. c. ACCEPTABLE MANUFACTURERS: VIKING, CENTRAL, STAR, RELIABLE. d. MATCH EXISTING • Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc ,11111111ilffir ', No.11400468 ; •; �• - o STATE OF oil w10 FIRE PROTECTION NOTES 1. DRAWINGS ARE DIAGRAMMATIC: DETERMINE LOCATIONS OF SYSTEMS AND COMPONENTS IN FIELD. 2. PITCH PRESSURE PIPING IN DIRECTION OF FLOW. 3. PRODUCT INSTALLATION SHALL ADHERE TO MANUFACTURERS' RECOMMENDATIONS. 4. NEITHER ACCURACY NOR COMPLETION OF UTILITY LOCATIONS SHOWN ON DRAWINGS IS GUARANTEED. DETERMINE EXACT LOCATIONS OF EXISTING UTILITIES IN FIELD, WHETHER OR NOT SHOWN ON DRAWINGS. EXERCISE CAUTION AND IDENTIFY LOCATIONS OF UNMARKED UTILITY LINES AS NECESSARY TO PERFORM WORK OF THIS SECTION. 5. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES AND DRAWINGS. 6. IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE HIS WORK WITH THAT OF ALL OTHERS TRADES AND GENERAL ARCHITECTURE. 7. ANY INTERFERENCE SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER AND THE OWNER'S REPRESENTATIVE, AND SHALL BE RESOLVED PRIOR TO THE INSTALLATION OF THE WORK INVOLVED. 8. VERIFY EXACT SIZES, LOCATIONS, INVERTS AND ELEVATIONS PRIOR TO FABRICATING AND INSTALLING ANY PIPING. 9. ALL PIPING PENETRATING CEILINGS AND WALLS SHALL BE INSTALLED WITH CHROME (STAINLESS WHERE NOTED) PLATED ESCUTCHEONS AT THE PENETRATION. PIPING PENETRATING RATED PARTITIONS SHALL BE PROTECTED AS BY LOCAL CODE AUTHORITY. 10. ALL SLEEVES THROUGH CONCRETE FLOORS AND ALL CORE DRILLING OF CONCRETE FLOORS AND WALLS SHALL BE BY THIS CONTRACTOR. 11. RUN PIPING CONCEALED, UNLESS SPECIFIED OTHERWISE, AND CLEAR OF CEILING INSERTS. 14. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS AND GUIDES AS NECESSARY TO PREVENT STRESS ON PIPING. 15. SPRINKLER CONTRACTOR SHALL HYDRAULICALLY CALCULATE NEW SYSTEM REQUIREMENTS BASED ON THE OCCUPANCY CLASSIFICATIONS AS INDICATED IN THE SPECIFICATIONS. 16. SPRINKLER CONTRACTOR SHALL OBTAIN A COPY OF THE BUILDING SYSTEM FLOW TEST. THESE FINDINGS SHALL BE USED FOR THE HYDRAULIC SPRINKLER SYSTEM CALCULATIONS. 17. SPRINKLER CONTRACTOR SHALL SCHEDULE WALK THRU WITH FIRE PREVENTION INSPECTOR FOR FINAL ACCEPTANCE AS REQUIRED. 18. SPRINKLER CONTRACTOR IS TO VERIFY SPRINKLER DISTRIBUTION SYSTEM & LAYOUT COMPLIES WITH NFPA 13 REQUIREMENTS. 19. FIRE PROTECTION PLANS AS SHOWN ARE FOR CONDITIONAL PLAN APPROVAL ONLY. FIRE PROTECTION CONTRACTOR IS TO OBTAIN CURRENT HYDRANT TEST DATA AND PROVIDE HYDRAULIC CALCULATIONS FOR SYSTEM PIPE SIZING IN ACCORDANCE WITH NFPA 13. CONTRACTOR IS TO SUBMIT SHOP DRAWINGS INDICATING HYDRAULIC CALCULATIONS, PIPING LAYOUT & SIZING. SHOP DRAWINGS AND CALCULATIONS ARE TO BE SIGNED & SEALED BY A CERTIFIED FIRE PROTECTION SYSTEM DESIGNER. ALL WORK IS TO BE DONE IN ACCORDANCE WITH ALL STATE, LOCAL, GOVERNING AND APPLICABLE CODES. 20. REPAIR ALL DAMAGED FIREPROOFING ON EXISTING STRUCTURE AFTER ALL FIRE PROTECTION WORK IS COMPLETED. 21. STATE CERTIFIED FIRE PROTECTION SYSTEM DESIGNER SHALL SUBMIT FINAL PLANS FOR PERMITTING AND CONSTRUCTION. 22. SPRINKLER CONTRACTOR SHALL VERIFY SPRINKLER HEAD COUNT PER FLOOR. A PROFESSIONAL ENGINEER COMPETENT IN AUTOMATIC FIRE SPRINKLER DESIGN SHALL BE REQUIRED FOR RENOVATIONS EXCEEDING 225 SPRINKLER HEADS (LIGHT HAZARD). REMOVE EXISTING SPRINKLER HEAD AND INSTALL NEW 1" OFFSET EXISTING SPRINKLER MAIN NEW SPRINKLER HEAD WITH CEILING PLATE MATCH EXISTING HEAD TYPE. NEW SUSPENDED CEILING. NEW CONCEALED PENDANT SPRINKLER DETAIL SCALE: NONE THREADED ROD CUT TO LENGTH CLEVIS TYPE PIPE HANGER CARRIER PIPE STEEL CLAMP ELASTOMERIC PAD CLEVIS TYPE PIPE SUPPORT FOR UNINSULATED PIPING DETAIL SCALE: NONE H E L L Y E R LEW AN Approved by: IS CJ ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Fire Protection Schedules, Legends and Notes No. FP -0.04 Drawn by: M E B Checked by: AN Approved by: AN Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Fire Protection Schedules, Legends and Notes No. FP -0.04 • Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 m\. 04C nn -1 c-7- 1 i SCALE: Fire Protection Plan 1/$., -o., FIRE PROTECTION PLAN CODED NOTES:O Di PROVIDE A MODIFIED HYDRAULICALLY CALCULATED AUTOMATIC SPRINKLER SYSTEM FOR THE AREA INDICATED. SPRINKLERS SHALL BE DESIGNED FOR LIGHT HAZARD OCCUPANCY, DELIVERING A DENSITY OF 0.10 GPM/SQ.FT OVER THE HYDRAULICALLY MOST REMOTE 1,500 SQ. FT. (165 DEGREE F RATED SEMI—RECESSED IN FINISHED CEILINGS). RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes IC'Itp at Caimal ntro DATE: 02/23/18 N H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Fire Protection Plan No. FP -1.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: 1/8" = V-0" Drawing: Fire Protection Plan No. FP -1.04 PIPE SUPPORT MEMBER, SEE NOTE 4. PANEL POINTS, SEE NOTE 4. r1nDDI IPATCII UUTAI DOUBLE NUT - FOR LOCKING / WASHER THICKNESS & REINFORCING SCHEDULE - * LOW PRESSURE DUCTWORK MINIMUM SHEET METAL THICKNESSES GREATEST DUCT STEEL DUCTS U.S. ALUMINUM DUCTS B & LONGITUDINAL TRANSVERSE JOINT TRANSVERSE JOINT REINFORCING (ALL DUCTS 18" THRU 54" SHALL BE CROSSBROKEN) DIMENSION STANDARD GAUGE S GAUGE SEAM SMALLEST DIMENSION GREATEST DIMENSION (MINIMUM THICKNESS, NOMINAL) 12" OR LESS 26 24(0.020') PITTSBURGH OR DRIVE SLIP OR POCKET PLAIN "S" SLIP OR POCKET NONE REQUIRED (26 GAGE, GALV.) 0.020 INCH (NO. 24 B&S GAGE) ACME LOCK LOCK OR BAR SLIP LOCK OR BAR SLIP INCH (24 GAGE, GALV.) 13" THRU 18" 24 22(0.025') PITTSBURGH OR DRIVE SLIP OR POCKET PLAIN "S" SLIP OR POCKET NONE REQUIRED (22 GAGE, GALV.) 0.032 INCH (NO. 20 B&S GAGE) ACME LOCK LOCK OR BAR SLIP LOCK OR BAR SLIP INCH (20 GAGE, GALV.) 19" THRU 30" 24 22(0.025') PITTSBURGH OR HEMMED "S" SLIP OR BAR HEMMED "S" SLIP OR BAR IF TRANSVERSE JOINTS ARE LOCATED 4'-0" OR LESS ON CENTER NO 0.051 INCH (NO. 16 B&S GAGE) NEW DUCTWORK ACME LOCK SLIP OR DRIVE SLIP OR 1" SLIP OR 1" POCKET LOCK REINFORCING IF ON 8'-0" CENTERS REINFORCE WITH 1"X1"X1/8" SPIRAL SEAM DUCT NOT TO SCALE POCKET LOCK FITTINGS ANGLES AT 4 FT. O.C. FASTENED ON 8" CENTERS 31 THRU 42" 22 20(0.032') PITTSBURGH OR DRIVE SLIP 18" OR LESS BAR SLIP OR REIN- FORCED IF TRANSVERSE JOINTS ARE LOCATED 4'-0" OR LESS ON CENTER NO (MINIMUM THICKNESS, NOMINAL) (MINIMUM THICKNESS, NOMINAL) ACME LOCK BAR SLIP REIN- FORCED BAR SLIP OR POCKET LOCK REINFORCING IF ON 8'-0" CENTERS REINFORCE WITH 1"X1"X1/8" 0.022 INCH (26 GAGE, GALV.) 0.022 INCH (26 GAGE, GALV.) 13 THROUGH 18 BAR SLIP OR POCKET LOCK 0.022 INCH (26 GAGE, ANGLES AT 4 FT. O.C. FASTENED ON 8" CENTERS 43" THRU 54" 22 20(0.032') PITTSBURGH LOCK 1 1/4" BAR SLIP, OR RE- 1 1/4" BAR SLIP, OR RE- IF TRANSVERSE JOINTS ARE LOCATED 4'-0" OR LESS ON CENTER NO 0.034 INCH (22 GAGE, GALV.) 0.034 INCH (22 GAGE, GALV.) 29 THROUGH 36 INFORCED BAR SLIP, OR 1 INFORCED BAR SLIP, OR 1 REINFORCING IF ON 8'-0" CENTERS REINFORCE WITH 1"X1"X1/8" 0.040 INCH (20 GAGE, GALV.) 0.040 INCH (20 GAGE, GALV.) 37 THROUGH 52 1/2" POCKET LOCK 1/2" POCKET LOCK ANGLES AT 4 FT. O.C. FASTENED ON 8" CENTERS 0.052 INCH (18 GAGE, GALV.) 0.052 INCH (18 GAGE, GALV.) EF EXHAUST FAN ANGLES TO BE THE SAME SIZE AS REQUIRED REINFORCING ANGLES QT THERMOSTAT 0 ANGLE SLIP ACME LOCK DRIVE SLIP POCKET LOCK BAR SLIP ANGLES TO BE THE I_1_I SAME SIZE AS REQUIRED REINFORCING ANGLES DIFFUSER OR GRILLE DESIGNATION a CD CAULK OR GASKET COMPANION ANGLES HEMMED "S" SLIP REINFORCED BAR SLIP PITTSBURGH LOCK PLAIN "S" SLIP ANGLES TO BE THE SAME SIZE AS REQUIRED REINFORCING ANGLES ANGLES TO BE THE SAME SIZE AS REQUIRED REINFORCING ANGLES ANGLE REINFORCED POCKET LOCK STANDING SEAM ALTERNATE BAR SLIP ANGLE REINFORCED STANDING SEAM NOTE: 1. LOW PRESSURE DUCTWORK SHALL BE DUCTWORK IN WHICH THE PRESSURE DOES NOT EXCEED 2" WATER GAUGE. WEBBING STEEL BAR JOIST DOUBLE LOCK NUT & HANGER ROD WASHER, SEE DETAIL "B". \ SIDE VIEW FRONT VIEW DETAIL A DETAIL B NOTES: HANGER CONFIGURATION 1. ALL DETAILS SHOWN SHALL BE SUBMITTED AS SHOP DRAWINGS AND SHALL BE REVIEWED 6. THIS CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES CONCERNED. BY THE REGISTERED STRUCTURAL ENGINEER. 7. PROVIDE APPROVED TYPE PIPE OR CHANNEL MEMBERS TO SUPPORT DUCTWORK AND OTHER 2. WHERE POSSIBLE ALL HANGERS SHALL BE SUSPENDED FROM WF BEAMS IN LIEU OF FROM JOIST. EQUIPMENT LOADS. 3. EQUIPMENT SHALL NOT BE HUNG FROM STEEL DECK OR FROM BRIDGING ANGLES. 8. ECCENTRIC BEAM CLAMPS WILL NOT BE ALLOWED. 4. HANGERS AND SUPPORTING MEMBERS SUCH AS PIPES & UNISTRUT SHALL BE LOCATED AT PANEL 9. AT FIRE RATED PARTITIONS, ADD ADDITIONAL LAYER OF FIRE SAFING INSULATION POINTS OF JOIST & SHALL BE SUPPORTED BY BAR JOISTS & NOT DIRECTLY BY WEBBING, AROUND PENETRATION SO AS TO FILL CAVITY. COORDINATE WITH STRUCTURAL ENGINEER. 10. DUCT PENETRATIONS THRU CORRIDOR WALLS ABOVE THE CEILING ARE TO BE "FIRE STOPPED" 5. THE SUM OF ALL BUILDING TRADES HANGER LOADS SHALL NOT EXCEED 250 LBS. PER AROUND THE PENETRATION. JOIST. WHEN THIS MAXIMUM IS EXCEEDED A DETAIL OF PROPOSED METHOD OF HANGING 11. METAL STRAPPING INSTALLED PER SMACNA CHAPTER 5 IS AN ACCEPTABLE MEANS FOR SHALL BE SUBMITTED FOR APPROVAL. SUPPORT. OPEN WEB JOIST DUCTWORK SUPPORT At 1111 Anln USING NYLON TY -W WITH TY -WRAP TOO S.S. DRAW BAND INTERNALLY INSULAI WITH INTEGRAL (N9 FABRICATED) ADJUSTABLE VANES LINEAR DIFFUSER SCALE: NONE SEE SPECS FOR CONNECTING DUCT SIZE SHALL BE SAME OS NOTES: DIFFUSER NECK UNLESS SHOWN OTHERWISE. 1. OFFSETS WITH FLEXIBLE DUCT SHALL NOT EXCEED 30' AND SHALL BE GRADUAL. OFFSETS IN EXCESS OF 30' SHALL BE HARD DUCTED. 2. FLEXIBLE DUCT SHALL NOT HAVE MORE THAN J" SAG PER FOOT. 3. FOR PERIMETER DIFFUSERS LOCATE DISTANCE FROM LINEAR DIFFUSER CONNECTION OUTSIDE WALL SHOWN ON ARCH. PLANS. SCALE: NONE 4. CONNECTION TO MAIN DUCT SHALL BE HARD DUCT TRANSITION AND VOLUME DAMPER. ELECTRICAL PANEL CIRCUIT SET WATER RETL GATE VALVE WATER SUP[ FLEXIBLE H( WITH BRASS ��;�,���� RELEASES IFR CmW3TRlllCTION 5uuh�j�o�ktio aumipdiian�c®wlNo ®III r�gwt'�timns rn95tal� emd Ilmeal Or'adle�� IC'Itp� o�F Cairrnrel "��� Dr�TEa 02/23/18 INSULATED FLEXIBLE CONNECTION ONE (1) FOOT MAX. LENGTH CEILING NOTE: INSTALL PER MANUFACTURES RECOMMENDATIONS SEPARATE "Y" TYPE STRAINER WITH BLOV DOWN VALVE AND HI THREAD CONNECTION (TYPICAL) TWO POSITION ISOLATION VALVE INTERLOCKED WITH COMPRESSOR CI BALL VALVE (TYPICAL Cl-- C1 AUTOFLOW SELF BAL VALVE, SEE HEAT PL SCHEDULE FOR GPM REQUIREMENTS PRESSURE/TEMPERAI PLUGS (TYPICAL) 3/4" BALL TYPE DRQ-, WITH CAPPED HOSE THREAD CONNECTION 1111\ I LVYY HORIZONTAL HEAT PUMP DETAIL SCALE: NONE BLOWER MOTOR ACCESS PANEL LITTLE GIANT MODEL VCC-20-P CONDENSATE PUMP AND TANK; 70 GPH AT 5' HD. 115-1-60 VOLTAGE 93 WATTS. WATER SOURCE HEAT PUMP PIPING SCHEMATIC SCALE: NONE DUCT CONSTRUCTION MINIMUM SHEET METAL THICKNESSES DENOTES EXISTING EQUIPMENT AND DEVICES TO BE REMOVED IN ITS ENTIRETY INCLUDING Y RECTANGULAR DUCTS LEW MAINTAINED. MAXIMUM SIZE DENOTES EXISTING EQUIPMENT AND DEVICES TO BE RELOCATED IN ITS ENTIRETY. RELOCATION C: STEEL SUPPLY OR OUTDOOR AIR DOWN DENOTES NEW LOCATION OF EXISTING RELOCATED ("XR") EQUIPMENT AND DEVICES. REWORK ALUMINUM (INCHES) (MINIMUM THICKNESS, NOMINAL) RETURN, OR RELIEF AIR DUCT DOWN (MINIMUM THICKNESS, NOMINAL) THROUGH 12 0.022 INCH (26 GAGE, GALV.) 0.020 INCH (NO. 24 B&S GAGE) 13 THROUGH 30 0.028 INCH (24 GAGE, GALV.) 01/26/18 0.025 INCH (NO. 22 B&S GAGE) 31 THROUGH 54 No. 0.034 INCH (22 GAGE, GALV.) 0.032 INCH (NO. 20 B&S GAGE) 55 THROUGH 84 0.040 INCH (20 GAGE, GALV.) 0.040 INCH (NO. 18 B&S GAGE) OVER 84 BALANCING (VOLUME) DAMPER 0.052 INCH (18 GAGE, GALV.) 0.051 INCH (NO. 16 B&S GAGE) NEW DUCTWORK ROUND DUCTS AFF ABOVE FINISHED FLOOR SPIRAL SEAM DUCT NOT TO SCALE LONGITUDINAL SEAM DUCT FITTINGS STEEL EXHAUST AIR STEEL STEEL MAXIMUM SIZE (INCHES) (MINIMUM THICKNESS, NOMINAL) (MINIMUM THICKNESS, NOMINAL) (MINIMUM THICKNESS, NOMINAL) THROUGH 12 SUPPLY AIR 0.019 INCH (28 GAGE, GALV.) ELECTRICAL CONTRACTOR 0.022 INCH (26 GAGE, GALV.) 0.022 INCH (26 GAGE, GALV.) 13 THROUGH 18 GC 0.022 INCH (26 GAGE, GALV.) 0.028 INCH (24 GAGE, GALV.) 0.028 INCH (24 GAGE, GALV.) 19 THROUGH 28 z 0.028 INCH (24 GAGE, GALV.) Q 0.034 INCH (22 GAGE, GALV.) 0.034 INCH (22 GAGE, GALV.) 29 THROUGH 36 PLUMBING CONTRACTOR 0.034 INCH (22 GAGE, GALV.) 0.040 INCH (20 GAGE, GALV.) 0.040 INCH (20 GAGE, GALV.) 37 THROUGH 52 0.040 INCH (20 GAGE, GALV.) CU 0.052 INCH (18 GAGE, GALV.) 0.052 INCH (18 GAGE, GALV.) HEAT PUMP AIR FLOW A/C CONDENSATE TRAP SEE - J"SCALE - PLAN OR GRILLE SCHEDULE FC METAL DUCT SIZES HANG FROM STRUCTURE (4)#10 GAUGE SHEET ME HANGERS SUPPORT FROM OVERHEAD STRUCTURE WITH THREADED RODS AND RUBBER GROMMET VIBRATION ISOLATION PER MANUFACTURER'S RECOMMENDATIONS AIR FLOW FILTER (MAINTAIN MINIMUM CLEARANCE) SECONDARY OVERFLOW 26 GAUGE GALVANIZED STEEL PAN, 2" DEPTH, AND DRAIN HEAT PUMP - DRAIN PAN SCALE: NONE RETURN AIR BOOT SCALE: NONE CONICAL BRANCH CONNECTION SQUARE, RECTANGULAR OR DAMPER W/ LOCKING QUADRANT ROUND DISTRIBUTION DUCT r --ROUND SHEET METAL DUCT INTERIOR ACOUSTICAL LINING FLOW CEILING RETURN AIR GRILLE ROUND FLEXIBLE DUCT 11 tillLIEN THTED FULLYOEXTENDED METAL BAND NSULATION R=2D CEILING DIFFUSER INSTALLATION DETAIL SCALE: NONE CEILING DIFFUSER GENERAL MECHANICAL HVAC NOTES 1. ALL "BUILDING STANDARDS" AND/OR "BUILDING SPECIFICATIONS" SHALL BE CONSIDERED AN INTEGRAL PART OF THESE DOCUMENTS AND THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN A COPY OF THESE DOCUMENTS AND COMPLY WITH ALL REQUIREMENTS, STANDARDS, AND SPECIFICATIONS CONTAINED WITHIN. 2. THESE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ARE INTENDED TO CONVEY THE SCOPE OF WORK AND INDICATE GENERAL ARRANGEMENT OF DUCTWORK, DIFFUSERS, GRILLES, THERMOSTATS, EQUIPMENT, DEVICES, ETC. THE LOCATIONS OF ALL ITEMS SHOWN ON THESE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED AT THE PROJECT. ALL LOCATIONS OF WORK EXPOSED TO VIEW ARE SUBJECT TO APPROVAL OF THE ARCHITECT PRIOR TO ROUGH -INS. 3. THE MECHANICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT ALL NEW WORK WILL FIT INTO THE EXISTING STRUCTURE AND CONDITIONS IN THE MANNER INTENDED AND AS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER PRIOR TO ANY ROUGH -INS, FABRICATIONS, OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A RFI, INCLUDING A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. 4. ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE PROMPTLY BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION DURING THE BIDDING PERIOD. NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF HIS FAILURE TO HAVE BROUGHT SAID DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT/ENGINEER DURING THE BIDDING PERIOD OR OF ANY ERROR ON THE CONTRACTOR'S PART. 5. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT, PROFESSIONAL AND WORKMANLIKE MANNER, RECTILINEAR TO FINISHES AND BUILDING STRUCTURE. 6. GENERAL NOTES, SYMBOL LEGENDS AND DETAILS ARE APPLICABLE TO ALL DRAWINGS WITHIN CONTRACT DOCUMENTS. 7. REFER TO ARCHITECTURAL ELEVATIONS TO DERIVE EXACT LOCATIONS OF ALL RELATED DIFFUSERS, GRILLES, EQUIPMENT, DEVICES, ETC. DIFFUSERS, GRILLES, AND ALL LUMINAIRES AND CEILING MOUNTED EQUIPMENT SHALL BE COORDINATED WITH THE ARCHITECTURAL RCP (REFLECTED CEILING PLANS). 8. COORDINATE WORK OF THIS SECTION WITH THAT OF ALL OTHER TRADES. 9. ALL DUCTWORK, PIPING, ETC. RUNNING THROUGH BUILDING EXPANSION JOINTS SHALL BE EQUIPPED WITH APPROPRIATE EXPANSION FITTINGS. 10. SHEET METAL FITTINGS SHOWN ARE TO BE PROVIDED. NO SUBSTITUTES SHALL BE ALLOWED WITHOUT PRIOR CONSENT FROM ENGINEER. 11. RUN DUCTS PIPING, ETC. CONCEALED, UNLESS SPECIFIED OTHERWISE, AND CLEAR OF CEILING INSERTS. ALL DUCTWORK SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO WALL AND UNDERSIDE OF BEAMS AND JOISTS.. 12. THE MECHANICAL HVAC CONTRACTOR SHALL REFER TO THE ELECTRICAL SPECIFICATIONS FOR ACCEPTABLE CONDUIT TYPES/LOCATIONS. 13. IT IS NOT INTENDED THAT THE PLANS INDICATE ALL OBSTRUCTIONS, NECESSARY BENDS, AND OFFSETS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL HIS WORK TO CONFORM AND SMACNA TO CODE REQUIREMENTS, THE STRUCTURE, MAINTAIN HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR. REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AS REQUIRED. 14. REFER TO SPECIFICATIONS FOR DUCTWORK, CONSTRUCTION CLASSES, SEAL, AND LEAKAGE CLASSES. 15. INSTALL THERMOSTAT AT ADA 4'-0" ABOVE FINISHED FLOOR OR AS DIRECTED OTHERWISE BY ARCHITECT. 16. ALL WORK SHALL BE COORDINATED WITH ALL JOB TRADES. OFFSETS IN DUCTS (INCLUDING DIVIDED DUCTS) TRANSITIONS AROUND OBSTRUCTIONS PIPING, ETC. SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 17. FIELD VERIFY THE EXACT LOCATION OF MECHANICAL HVAC EQUIPMENT THAT REQUIRES ELECTRICAL CONNECTIONS WITH RESPECTIVE CONTRACTORS. 18. VERIFY ALL EQUIPMENT CONNECTIONS WITH MANUFACTURER'S SPECIFICATIONS AND INSTALLATION DRAWINGS. VERIFY AND PROVIDE DUCT TRANSITIONS TO EQUIPMENT AS REQUIRED. FIELD VERIFY AND COORDINATE ALL DIMENSIONS BEFORE FABRICATION. 19. ACCESS PANELS SHALL BE PROVIDED TO CLEAN AND SERVICE COILS AND DAMPERS, HEATERS, VALVES, ETC., AND ALL CONCEALED MECHANICAL EQUIPMENT THAT REQUIRES ACCESS. 20. SUPPORT ALL EQUIPMENT, DUCTWORK, PIPING, ETC. FROM BUILDING STRUCTURE TO PROVIDE A VIBRATION FREE INSTALLATION. NOTIFY ARCHITECT AND STRUCTURAL ENGINEER OF ALL WEIGHTS AND METHODS OF SUPPORT PRIOR TO ANY ROUGH -INS OR INSTALLATIONS. 21. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH N.E.C. REQUIREMENTS AND ELECTRICAL SPECIFICATIONS. 22. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, UNLESS NOTED OTHERWISE. 23. DIFFUSER SIZES SHOWN ARE NECK SIZES; REGISTER AND GRILLE SIZE ARE NOMINAL. SUPPLY DUCT TO DIFFUSERS/GRILLES SHALL EQUAL NECK SIZE UNLESS SHOWN OTHERWISE. 24. THE INSIDE OF ALL UNLINED DUCTWORK VISIBLE THROUGH A GRILLE OR DIFFUSER SHALL BE PAINTED FLAT BLACK. 25. INSULATE ALL SUPPLY AIR DUCTWORK IN CONCEALED AND RETURN AIR PLENUMS WITH MINIMUM R-3.5 (VERIFY WITH ASHRAE CLIMATE ZONE) ALL SERVICE FIBER GLASS DUCT WRAP WITH FRK VAPOR RETARDING FACING. DUCT WRAP IN RETURN AIR PLENUM SHALL COMPLY WITH ASTM E 84 (FLAME SPREAD - 25, SMOKE DEVELOPED - 50). 26. INTERNAL AIR FLOW DIMENSIONS ARE SHOWN FOR DUCTS. CONTRACTOR SHALL INCREASE SIZE FOR LINER IF APPLICABLE. 27. MECHANICAL HVAC CONTRACTOR SHALL FIELD VERIFY ALL EXISTING ITEMS, SIZES, AND MATERIALS BEFORE FABRICATION OR PURCHASE OF ALL NEW ITEMS. 28. CONTRACTOR SHALL PROVIDED ALL NECESSARY INCREASERS/DECREASERS TO ADAPT NEW DUCTWORK TO EXISTING DUCTWORK. 29. REPAIR FIREPROOFING AFTER INSTALLATION OF HANGERS AND SUPPORTS TO ORIGINAL CONDITIONS. 30. PROVIDE FIRE DAMPERS AND ASSOCIATED ACCESS PANELS WHERE SHOWN ON DRAWINGS AND WHERE REQUIRED BY CODE. FOR DUCTS THAT PENETRATE FIRE WALLS, FLOORS AND PARTITIONS PROVIDE SLEEVES WHERE PENETRATIONS ARE NOT PERPENDICULAR TO SURFACE PENETRATED, ENCLOSE DAMPERS IN 10 GAUGE STEEL SLEEVE. 31. MAINTAIN CODE AND MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES FOR EQUIPMENT. 32. EXHAUST FANS/DUCTS AND ROOF VENTS SHALL TERMINATE A MINIMUM OF 10'-0" FROM OUTSIDE AIR INTAKES. 33. ALL MATERIALS IN CEILING SPACE SHALL BE PLENUM RATED PER CODE. 34. PROVIDE SECONDARY/AUXILLIARY DRAIN PAN PER SPECIFICATIONS FOR ALL CEILING MOUNTED EQUIPMENT WITH CONDENSATE OR WATER PIPING CONNECTIONS. MECHANICAL DEMOLITION NOTES 1. IN EVERY INSTANCE OF DEMOLITION AND/OR REMODELING, THE MECHANICAL CONTRACTOR SHALL FIGURE A COMPLETE JOB AS NONE OTHER SHALL BE ACCEPTED. 2. THESE NOTES ARE TO BE USED ONLY AS A GUIDELINE FOR DEMOLITION. THE MECHANICAL CONTRACTOR MUST VISIT THE SITE PRIOR TO BIDDING TO VERIFY ALL WORK REQUIRED FOR A COMPLETE JOB AND INCLUDE THE COST OF SUCH WORK IN HIS BID. 3. THE MECHANICAL CONTRACTOR SHALL MAINTAIN EXISTING SERVICES TO AND IN THE EXISTING AREA AS REQUIRED ARRANGEMENTS SHALL BE MADE WITH THE OWNER PRIOR TO THE INTERRUPTION OF ANY SERVICE WITHIN THE BUILDING. 4. THE MECHANICAL HVAC CONTRACTOR SHALL PROVIDE TEMPORARY SERVICES IN THE EXISTING AREA.. 5. THE MECHANICAL HVAC CONTRACTOR SHALL CAP ALL DUCTWORK TO REMAIN AND CAP OR PROVIDE FILTERS FOR ALL RETURN AIR OPENINGS TO SPACE. 6. THE MECHANICAL HVAC CONTRACTOR SHALL PROVIDE PROTECTION FOR ALL DUCT SMOKE DETECTION DEVICES, AND COORDINATE SHUT -DOWNS WHEN NECESSARY. 7. ALL MECHANICAL HVAC EQUIPMENT AND DEVICES SHALL BE REMOVED COMPLETE AND TURNED OVER TO OWNER. 8. ANY EXISTING DUCTWORK, PIPING AND/OR ELECTRICAL AND MECHANICAL DEVICES BEING DISTURBED BY THE WORK SHALL BE REWORKED BY THIS CONTRACTOR AS REQUIRED TO RETURN TO ITS FORMER EXISTING OPERATING CONDITION. 9. ALL WALLS, CEILINGS, FLOORS, ETC. BEING DISTURBED BY THE WORK SHALL BE RETURNED TO FINISHED CONDITIONS THE MECHANICAL HVAC CONTRACTOR SHALL DO HIS OWN CUTTING AND PATCHING AS NECESSARY UNDER HIS CONTRACT. 10. EXISTING MATERIAL SHALL BE TURNED OVER TO THE OWNER. IF NOT REQUIRED BY OWNER, THE MECHANICAL CONTRACTOR SHALL REMOVE THESE MATERIALS FROM THE PREMISES. • Integrated (LI(CE Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc '4 O No. 11400468 = •� • - o'STATE OF MECHANICAL HVAC SYMBOL LEGEND E DENOTES EXISTING EQUIPMENT AND DEVICES TO BE REMOVED IN ITS ENTIRETY INCLUDING Y BRANCH DUCTWORK, PIPING, CONTROL WIRING, BACK TO SOURCE OR NEXT ACTIVE ITEM BEING LEW MAINTAINED. SUPPLY OR OUTDOOR AIR DUCT UP DENOTES EXISTING EQUIPMENT AND DEVICES TO BE RELOCATED IN ITS ENTIRETY. RELOCATION C: TO NEW LOCATION ("XN") IS INDICATED ON "NEW WORK" DRAWINGS. SUPPLY OR OUTDOOR AIR DOWN DENOTES NEW LOCATION OF EXISTING RELOCATED ("XR") EQUIPMENT AND DEVICES. REWORK RE RETURN, OR RELIEF AIR DUCT UP REQUIRED/INDICATED. RETURN, OR RELIEF AIR DUCT DOWN DENOTES EXISTING EQUIPMENT TO BE MAINTAINED. EXHAUST DUCT UP .< EXHAUST DUCT DOWN Issue Date: 01/26/18 Issue For Permit: 01/29/18 MITERED DUCT ELBOW WITH TURNING No. Date VANES SQUARE TO ROUND TRANSITION INTERNAL DUCT INSULATION BALANCING (VOLUME) DAMPER X X EXISTING ITEM TO BE REMOVED NEW DUCTWORK EXISTING DUCTWORK/EQUIPMENT TO REMAIN AFF ABOVE FINISHED FLOOR NTS NOT TO SCALE TYP TYPICAL EA EXHAUST AIR I? RA RETURN AIR 0 a In SA SUPPLY AIR EC ELECTRICAL CONTRACTOR z 0 I_1_I M GC GENERAL CONTRACTOR o Scale: 1/8" = 1'-0" z MC MECHANICAL CONTRACTOR Q PC PLUMBING CONTRACTOR o r TCC TEMPERATURE CONTROL CONTRACTOR 0 z CU CONDENSING UNIT w EF EXHAUST FAN z QT THERMOSTAT 0 Ln QS TEMPERATURE SENSOR U) I_1_I ixx MARKCFM DIFFUSER OR GRILLE DESIGNATION a CD CONDENSATE DRAIN LINE DEMOLITION ANNOTATION LEGEND E DENOTES EXISTING EQUIPMENT AND DEVICES TO BE REMOVED IN ITS ENTIRETY INCLUDING Y BRANCH DUCTWORK, PIPING, CONTROL WIRING, BACK TO SOURCE OR NEXT ACTIVE ITEM BEING LEW MAINTAINED. "XR" DENOTES EXISTING EQUIPMENT AND DEVICES TO BE RELOCATED IN ITS ENTIRETY. RELOCATION C: TO NEW LOCATION ("XN") IS INDICATED ON "NEW WORK" DRAWINGS. "XN" DENOTES NEW LOCATION OF EXISTING RELOCATED ("XR") EQUIPMENT AND DEVICES. REWORK RE OR PROVIDE NEW BRANCH DUCTWORK, PIPING, CONTROL WIRING, ETC. TO NEW LOCATION AS REQUIRED/INDICATED. "XM" DENOTES EXISTING EQUIPMENT TO BE MAINTAINED. H E L L Y E R LEW Approved by: IS C: ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. PhiIa., PA 1 91 07 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Mechanical HVAC Details, Legends and Notes No. M-0.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Mechanical HVAC Details, Legends and Notes No. M-0.04 DUCTLESS SPLIT SYSTEM DS,CU) MANUFACTURER MODEL MODEL FAN COOLING MBH SYSTEM ELECTRICAL MARK MANUFACTURER EVAP CFM MCA MOCP EER REMARKS TOTAL CFM OA CFM TSP (IN WG) TOTAL MBH SENSIBLE MBH EVAP CONDENSER EWT ('F) EVAP CU VOLTAGE MCA MOCP DS -4-1, LIEBERT SRC18HPN SRC18HPC 400 18.2 14.7 208-1 19 25 CU -4-1 26.5 80 67 1 95 48.3 68 70 60 NOTES: 277-1 21.6 35 PROVIDE WITH FACTORY INSTALLED CONDENSATE PUMP. 8,10 (XM)WSHP-4-2 MCQUAY PROVIDE WITH CONDENSATE DRIP PAN. HORIZONTAL 1200 120 PROVIDE WITH 7 DAY PROGRAMMABLE THERMOSTAT. 7.5 4.7 35.6 SEVEN YEAR COMPRESSOR WARRANTY 80 67 85 PROVIDE WITH LOW AMBIENT WIND BAFFLE. 48.3 68 70 RELEASED IFCR CONSTRUCTION Subject to aompdiianice with ®III regofatiens of State and ILonal Endes ICltp of Caimal ntro DATE: 02/23/18 Nick MichlerMichler WATER SOURCE HEAT PUMP SCHEDULE WSHP VENTILATION REQUIREMENTS MARK MANUFACTURER MODEL TYPE FAN GPM SFT) COOLING HEATING VOLTAGE MCA MOCP EER REMARKS TOTAL CFM OA CFM TSP (IN WG) TOTAL MBH SENSIBLE MBH EAT DB ('F) EAT WB ('F) EWT ('F) LWT ('F) MBH EAT ('F) EWT ('F) LWT ('F) COP (XM)WSHP-4-1 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 48.3 68 70 60 4.7 277-1 21.6 35 - 8,10 (XM)WSHP-4-2 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 48.3 68 70 60 4.7 277-1 21.6 35 - 8,10 (XM)WSHP-4-3 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 48.3 68 70 60 4.7 277-1 21.6 35 - 8,10 (XM)WSHP-4-4 MCQUAY CCH024 HORIZONTAL 800 80 0.1 5.0 15.9 23.2 16.9 80 67 85 95 33.4 68 70 60 4.6 277-1 14.5 20 - 8,10 (XM)WSHP-4-5 MCQUAY CCH024 HORIZONTAL 800 80 0.1 5.0 15.9 23.2 16.9 80 67 85 95 33.4 68 70 60 4.6 277-1 14.5 20 - 8,10 (XN)WSHP-4-6 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 48.3 68 70 60 4.7 277-1 21.6 35 - 9,10 (X)WSHP-4-7 DEMO/NOT USED (XM)WSHP-4-8 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 48.3 68 70 60 4.7 277-1 21.6 35 - 8,10 (XM)WSHP-4-9 MCQUAY CCH024 HORIZONTAL 800 80 0.1 5.0 15.9 23.2 16.9 80 67 85 95 33.4 68 70 60 4.6 277-1 14.5 20 - 8,10 (XM)WSHP-4-10 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 48.3 68 70 60 4.7 277-1 21.6 35 - 8,10 (XN)WSHP-4-11 MCQUAY CCH030 HORIZONTAL 1000 100 0.1 7.3 27.5 58.7 41.9 80 67 85 95 42.5 68 70 60 4.9 277-1 19.5 30 - 9,10 (XN)WSHP-4-12 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 48.3 68 70 60 4.7 277-1 21.6 35 - 8,10 (XM)WSHP-4-13 MCQUAY CCH024 HORIZONTAL 800 80 0.1 5.0 15.9 23.2 16.9 80 67 85 95 33.4 68 70 60 4.6 277-1 14.5 20 - 8,10 (XN)WSHP-4-14 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 48.3 68 70 60 4.7 277-1 21.6 35 - 9,10 (XM)WSHP-4-15 MCQUAY CCH024 HORIZONTAL 800 80 0.1 5.0 15.9 23.2 16.9 80 67 85 95 33.4 68 70 60 4.6 277-1 14.5 20 - 8,10 (XM)WSHP-4-16 MCQUAY CCH030 HORIZONTAL 1000 100 0.1 7.3 27.5 58.7 41.9 80 67 85 95 42.5 68 70 60 4.9 277-1 19.5 30 - 8,10 (XM)WSHP-4-17 MCQUAY CCH024 HORIZONTAL 800 73 0.1 5.0 15.9 23.2 16.9 80 67 85 95 33.4 68 70 60 4.6 277-1 14.5 20 - 8,10 (XM)WSHP-4-18 MCQUAY CCH024 HORIZONTAL 800 94 0.1 5.0 15.9 23.2 16.9 80 67 85 95 33.4 68 70 60 4.6 277-1 14.5 20 - 8,10 (XM)WSHP-4-19 MCQUAY CCH030 HORIZONTAL 1000 73 0.1 7.3 27.5 58.7 41.9 80 67 85 95 42.5 68 70 60 4.9 277-1 19.5 30 - 8,10 (XM)WSHP-4-20 MCQUAY CCH030 HORIZONTAL 1000 100 0.1 7.3 27.5 58.7 41.9 80 67 85 95 42.5 68 70 60 4.9 277-1 19.5 30 - 8,10 (XM)WSHP-4-21 MCQUAY CCH030 HORIZONTAL 1000 100 0.1 7.3 27.5 58.7 41.9 80 67 85 95 42.5 68 70 60 4.9 277-1 19.5 30 - 8,10 (X)WSHP-4-22 DEMO/NOT USED (XM)WSHP-4-23 MCQUAY CCH030 HORIZONTAL 1000 100 0.1 7.3 27.5 58.7 41.9 80 67 85 95 42.5 68 70 60 4.9 277-1 19.5 30 - 8,10 (XM)WSHP-4-24 MCQUAY CCH024 HORIZONTAL 800 75 0.1 5.0 15.9 23.2 16.9 80 67 85 95 33.4 68 70 60 4.6 277-1 14.5 20 - 8,10 (X)WSHP-4-25 DEMO/NOT USED (XM)WSHP-4-26 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 20.7 68 70 60 5.3 277-1 21.6 57 - 1,2,3,4,5,6,7,10,11,12 (XM)WSHP-4-27 MCQUAY CCH024 HORIZONTAL 800 80 0.1 5.0 15.9 23.2 16.9 80 67 85 95 42.5 68 70 60 4.9 277-1 14.5 20 - 1,2,3,4,5,6,7,10,11,12 (XM)WSHP-4-28 MCQUAY CCH036 HORIZONTAL 1200 120 0.1 7.5 4.7 35.6 26.5 80 67 85 95 20.7 68 70 60 5.3 277-1 21.6 57 - 1,2,3,4,5,6,7,10,11,12 (XM)WSHP-4-29 MCQUAY CCH024 HORIZONTAL 800 160 0.1 5.0 15.9 23.2 16.9 80 67 85 95 42.5 68 70 60 4.9 277-1 14.5 20 - 1,2,3,4,5,6,7,10,11,12 WSHP-4-30 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-31 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-32 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-33 DAIKIN CCH015 HORIZONTAL 500 50 0.1 3.8 4.2 14.9 10.9 80 67 85 95 20.7 68 70 60 5.3 277-1 8.9 15 15.5 1,2,3,4,5,6,7,10,11,12 WSHP-4-34 DAIKIN CCH030 HORIZONTAL 1000 90 0.1 7.5 5.7 30.4 21.8 80 67 85 95 42.5 68 70 60 4.9 277-1 18.1 25 14.7 1,2,3,4,5,6,7,10,11,12 WSHP-4-35 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-36 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-37 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-38 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-39 DAIKIN CCH019 HORIZONTAL 630 60 0.1 4.5 2.6 21.3 16.0 80 67 85 95 27.3 68 70 60 4.7 277-1 9.9 15 14.7 1,2,3,4,5,6,7,10,11,12 WSHP-4-40 DAIKIN CCH009 HORIZONTAL 315 35 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-41 DAIKIN CCH015 HORIZONTAL 500 48 0.1 3.8 4.2 14.9 10.9 80 67 85 95 20.7 68 70 60 5.3 277-1 8.9 15 15.5 1,2,3,4,5,6,7,10,11,12 WSHP-4-42 DAIKIN CCH009 HORIZONTAL 315 31 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-43 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-44 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 WSHP-4-45 DAIKIN CCH019 HORIZONTAL 630 45 0.1 4.5 2.6 21.3 16.0 80 67 85 95 27.3 68 70 60 4.7 277-1 9.9 15 14.7 1,2,3,4,5,6,7,10,11,12 WSHP-4-46 DAIKIN CCH009 HORIZONTAL 315 45 0.1 3.8 8.7 8.8 7.7 80 67 85 95 14.8 68 70 60 8.9 277-1 4.8 15 12.5 1,2,3,4,5,6,10,11,12 REMARKS: 1. PRESSURE DROP RATING (IN FEET OF WATER) DOES NOT INCLUDE HOSE KITS. 2. RATINGS SHALL BE BASED ON ARI STANDARD 13256-1. 3. PROVIDE WITH DELUXE 24V CONTROLS. 4. PROVIDE WITH CIRCUIT SETTER FLOW CONTROL HOSE KIT. 5. PROVIDE WITH LITTLE GIANT CONDENSATE PUMP. 6. PROVIDE WITH LEAK DETECTION/CONDENSATE OVERFLOW TO SHUT DOWN UNIT. 7. PROVIDE WITH ECM MOTOR AND SWITCH FOR AIRFLOW SETTING ADJUSTMENT. 8. EXISTING HEAT PUMP. 9. EXISTING RELOCATED HEAT PUMP. 10. PROVIDE WITH NEW DAIKIN THERMOSTAT TIED INTO BUILDING AUTOMATION SYSTEM. DAIKIN P/N 668375401 11. PROVIDE WITH NON-FUSED DISCONNECT SWITCH. 12. PROVIDE WITH AUTOMATIC FLOW HOSE KIT. REGISTER, GRILLE & DIFFUSER SCHEDULE GRD VENTILATION REQUIREMENTS MARK SERVICE ROOM OCCUPANCY MODEL � PEOPLE/100 FRAME SIZE CFM/PERSON CFM/SQUARE OUTDOOR EXHAUST OUTDOOR EXHAUST MECHANICAL PRICE AREA 6"0 PEOPLE 25 FOOT AIR CFM AIR CFM AIR CFM AIR CFM NAME DESCRIPTION SQ.FT. SLOT REQUIRED REQUIRED REQUIRED REQUIRED PROVIDED PROVIDED UNIT PRICE OFFICE SPACE 23372 5 117 5 0.06 1987 400 3660 600 * ALL MINIMUM OUTSIDE AIR REQUIREMENTS ARE BASED ON ASHRAE 62.1-2010. REGISTER, GRILLE & DIFFUSER SCHEDULE GRD Z�_-CFMK MARK SERVICE MANUFACTURER CFM RANGE MODEL NECK SIZE FRAME SIZE MAX NC DAMPER FINISH BORDER REMARKS A SUPPLY PRICE TBD3100 6"0 4'-0", 1" SLOT,2 25 VCR 6 BY ARCH LAYIN 1 Issue Date: SLOT Issue For Permit: 01/29/18 No. Date B SUPPLY PRICE TBD3100 8"0 4'-0", 1" SLOT,2 25 VCR 6 BY ARCH LAYIN 1 SLOT C SUPPLY PRICE TBD3100 12"0 4'-0", 1" SLOT,2 25 VCR 6 BY ARCH LAYIN 1 SLOT D SUPPLY PRICE 0-100 SPD 6"0 24"x24" 25 VCR 6 BY ARCH LAYIN 1 E SUPPLY PRICE 100-280 SPD 8"0 24"x24" 25 VCR 6 BY ARCH LAYIN 1 F SUPPLY PRICE 280-435 SPD 10"0 24"x24" 25 VCR 6 BY ARCH LAYIN 1 G RETURN PRICE 80 22x22 24"x24" 25 VCR 6 BY ARCH LAYIN 1 H RETURN PRICE 80 22x10 24"x12" 25 VCR 6 BY ARCH LAYIN 1 J SUPPLY PRICE TBD3100 10"o 4'-0", 1" SLOT,2 25 VCR 6 BY ARCH LAYIN 1 SLOT REMARKS: 1. THE MECHANICAL HVAC CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO COORDINATE AND VERIFY ALL CEILING TYPES WITH ARCHITECT AND ARCHITECTURAL CEILING PLANS, DETAILS, SCHEDULES, ETC., INCLUDING, BUT NOT LIMITED TO DIFFUSER/GRILLE COLORS, LENGTHS, TRIMS, FINISHES, FRAMES, MOUNTING CONFIGURATIONS AND HARDWARE, ETC. PRIOR TO ANY ROUGH -INS AND PLACING FINAL PURCHASE ORDERS. 2. SEE FLOOR PLANS FOR CFM. 3. CONNECTING DUCTWORK SHALL BE SIZED TO MAKE NECK, UNLESS SHOWN OTHERWISE. • Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc No. 11400468 = o STATE OFIll Will H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual® INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Mechanical Schedules HVACI No. M-0. 14 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Mechanical Schedules HVACI No. M-0. 14 MECHANICAL HVAC DEMOLITION PLAN GENERAL NOTES: 1. MECHANICAL HVAC CONTRACTOR SHALL COORDINATE ANY NECESSARY SHUTDOWNS WITH BUILDING/MANAGEMENT. 2. MECHANICAL HVAC CONTRACTOR SHALL PERFORM A FIELD SURVEY PRIOR TO COMMENCING WITH DEMOLITION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND FOR DIRECTION PRIOR TO COMMENCING WITH DEMOLITION. 3. ANY EXISTING SYSTEMS AND/OR EQUIPMENT NOTED AS EXISTING TO REMAIN SHALL BE FIELD VERIFIED FOR DEFICIENCIES. NOTIFY ARCHITECT AND ENGINEER OF ANY DEFICIENCIES DISCOVERED. 4. EXISTING EQUIPMENT TO BE RELOCATED SHALL BE INSPECTED PRIOR TO RELOCATION. NOTIFY ARCHITECT AND ENGINEER OF ANY DEFICIENCIES DISCOVERED. 5. PROJECT SCOPE INVOLVES REMOVAL AND MODIFICATION TO CONDENSER WATER PIPING SYSTEM. CONTRACTOR SHALL ISOLATE/SHUTOFF SYSTEM AND DRAIN (AND PROPERLY DISPOSE) TO ACCOMMODATE SCOPE OF WORK. 6. MECHANICAL HVAC CONTRACTOR SHALL REFER TO ALL SHEETS CONTAINED IN DRAWING SET FOR COMPLETE SCOPE OF WORK. TYPICAL DETAILS, INSTALLATION REQUIREMENTS AND GENERAL BUILDING STANDARDS ARE REFERENCED AND APPLICABLE TO THESE CONTRACT DOCUMENTS. 7. CODED NOTE NUMBERS USED/NOT USED FOR CONSISTENCY BETWEEN SHEETS. 8. IT IS THE INTENT TO REUSE DUCTWORK WHERE PRACTICAL. CONTRACTOR MAY REUSE DUCT TAPS OF EQUAL SIZE. ANY EXISTING CONDITIONS THAT VARY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO FABRICATION OR INSTALLATION OF NEW HVAC SYSTEMS. RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes ICltp at Caimal ntro DATE: 02/23/18 • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc s No. 11400468 = •� '• Mechanical HVAC Demolition Plan SCALE: ,/$„ : MECHANICAL HVAC DEMOLITION PLAN CODED NOTES: XX 0 REMOVE AND DISCARD EXISTING HEAT PUMP COMPLETE. 0 EXISTING HEAT PUMP TO BE RELOCATED. REMOVE AND DISCARD EXISTING DUCTWORK. REMOVE AND DISCARD EXISTING PIPING BACK TO MAIN AND CAP. O REMOVE AND DISCARD EXISTING ABANDONED DUCTWORK ABOVE CEILING. ® REMOVE AND DISCARD EXISTING DIFFUSER. MAINTAIN DUCTWORK FOR CONNECTION TO NEW. O5 REMOVE AND DISCARD EXISTING DIFFUSER. CAP DUCTWORK AT CONNECTION TO MAIN. © REMOVE AND DISCARD EXISTING DIFFUSER AND DUCTWORK TO POINT INDICATED. CAP AT POINT INDICATED. 0 REMOVE AND DISCARD EXISTING RETURN GRILLE. TYPICAL ALL. ® EXISTING BUILDING SENSOR TO REMAIN. O9 REMOVE AND DISCARD EXISTING DUCTWORK TO POINT INDICATED. MAINTAIN FOR CONNECTION TO NEW. 10 REMOVE AND DISCARD EXISTING DUCTWORK BACK TO MAIN AND CAP. N H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Mechanical HVAC Demolition Planl No. M-1.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Mechanical HVAC Demolition Planl No. M-1.04 MECHANICAL HVAC PIPING DEMOLITION PLAN GENERAL NOTES: 1. MECHANICAL HVAC CONTRACTOR SHALL COORDINATE ANY NECESSARY SHUTDOWNS WITH BUILDING/MANAGEMENT. 2. MECHANICAL HVAC CONTRACTOR SHALL PERFORM A FIELD SURVEY PRIOR TO COMMENCING WITH DEMOLITION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND FOR DIRECTION PRIOR TO COMMENCING WITH DEMOLITION. 3. ANY EXISTING SYSTEMS AND/OR EQUIPMENT NOTED AS EXISTING TO REMAIN SHALL BE FIELD VERIFIED FOR DEFICIENCIES. NOTIFY ARCHITECT AND ENGINEER OF ANY DEFICIENCIES DISCOVERED. 4. EXISTING EQUIPMENT TO BE RELOCATED SHALL BE INSPECTED PRIOR TO RELOCATION. NOTIFY ARCHITECT AND ENGINEER OF ANY DEFICIENCIES DISCOVERED. 5. PROJECT SCOPE INVOLVES REMOVAL AND MODIFICATION TO CONDENSER WATER PIPING SYSTEM. CONTRACTOR SHALL ISOLATE/SHUTOFF SYSTEM AND DRAIN (AND PROPERLY DISPOSE) TO ACCOMMODATE SCOPE OF WORK. 6. MECHANICAL HVAC CONTRACTOR SHALL REFER TO ALL SHEETS CONTAINED IN DRAWING SET FOR COMPLETE SCOPE OF WORK. TYPICAL DETAILS, INSTALLATION REQUIREMENTS AND GENERAL BUILDING STANDARDS ARE REFERENCED AND APPLICABLE TO THESE CONTRACT DOCUMENTS. 7. CODED NOTE NUMBERS USED/NOT USED FOR CONSISTENCY BETWEEN SHEETS. 8. IT IS THE INTENT TO REUSE DUCTWORK WHERE PRACTICAL. CONTRACTOR MAY REUSE DUCT TAPS OF EQUAL SIZE. ANY EXISTING CONDITIONS THAT VARY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO FABRICATION OR INSTALLATION OF NEW HVAC SYSTEMS. RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes ICltp at Caimal ntro DATE: 02/23/18 • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc s No. 11400468 = •� '• Mechanical HVAC Piping Demolition Plan SCALE: ,/$„ : MECHANICAL HVAC PIPING DEMOLITION PLAN CODED NOTES: XX O1 REMOVE AND DISCARD EXISTING WSHP COMPLETE. CAP CONDENSER WATER SUPPLY, RETURN AND CONDENSATE PIPING AT CONNECTION TO MAIN. O EXISTING WSHP TO BE RELOCATED. CAP PIPING AT CONNECTION TO MAIN. SEE SHEET M4.04 FOR NEW LOCATION. O EXISTING WHSP TO BE RELOCATED. REWORK EXISTING WATER AND CONDENSATE PIPING TO ACCOMMODATE NEW LOCATION. N H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Mechanical HVAC Piping Demolition Plan No. M-2.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Mechanical HVAC Piping Demolition Plan No. M-2.04 MECHANICAL HVAC PLAN GENERAL NOTES: 1. MECHANICAL HVAC CONTRACTOR SHALL PERFORM A FIELD SURVEY PRIOR TO FABRICATING OR INSTALLING ANY NEW WORK OR MODIFYING EXISTING. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND FOR DIRECTION PRIOR TO PROCEEDING. 2. ANY EXISTING SYSTEMS NOTED AS EXISTING TO REMAIN SHALL BE FIELD VERIFIED FOR DEFICIENCIES. 3. MECHANICAL HVAC CONTRACTOR SHALL COORDINATE ANY NECESSARY SHUTDOWNS WITH BUILDING/MANAGEMENT. 4. MECHANICAL HVAC CONTRACTOR SHALL CAP ALL UNUSED DUCT TAPS AND OPENINGS ON EXISTING SUPPLY AIR DUCT MAIN AND SEAL AIR TIGHT. 5. MECHANICAL HVAC CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS REQUIRED FOR THEIR TRADE. SEE ARCHITECTURAL DRAWINGS FOR SPECIFICATIONS. 6. ROUTE DUCTWORK BETWEEN JOISTS AND HIGH AS POSSIBLE THROUGHOUT SPACE. TRANSITION DOWN TO ACOUSTICAL CEILING. 7. MECHANICAL HVAC CONTRACTOR SHALL REUSE EXISTING DUCTWORK AS PRACTICAL. 8. RELOCATE RETURN AIR GRILLES ACCORDING TO NEW CEILING GRID. 9. RELOCATE SUPPLY AIR GRILLES AS REQUIRED FOR NEW CEILING GRID. MAKE NECESSARY ADJUSTMENTS IN DUCTWORK WHERE REQUIRED. 10. ALL THERMOSTATS LOCATED WITHIN PRIVATE OFFICES ARE TO BE LOCATED WITHIN 18" OF THE DOOR OPENING. 11. MECHANICAL HVAC CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND PREPARE INTERFERENCE DRAWINGS FOR SUBMITTAL, PRIOR TO ANY FABRICATION OR INSTALLATION. RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes IC'Itp at Caimal ntro DATE: 02/23/18 235 330 235 235 235 200 A2O • Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (PN. ?1A Qn1 A711 '% Mechanical HVAC Plan SCALE: ,,8., _,._o., MECHANICAL HVAC PLAN CODED NOTES: O O1 PROVIDE NEW THERMOSTAT AS SPECIFIED AND CONTROL WIRING FOR EXISTING HEAT PUMP. TIE INTO BUILDING AUTOMATION SYSTEM AS REQUIRED BY LANDLORD. COORDINATE WITH LANDLORD FOR ADDITIONAL INFORMATION. 0 BALANCE FLOOR OUTDOOR AIR EVENLY BETWEEN OUTLETS. 0 BALANCE BRANCH DUCTWORK TO DISCHARGE CFM INDICATED INTO PLENUM SPACE. ® REBALANCE EXISTING HEAT PUMP TO CFM INDICATED. M 250 AINM A N H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Mechanical HVAC Plan No. M-3.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision --r i Scale: 1/8" = V-0" Drawing: Mechanical HVAC Plan No. M-3.04 MECHANICAL HVAC PIPING PLAN GENERAL NOTES: 1. MECHANICAL HVAC CONTRACTOR SHALL COORDINATE ANY NECESSARY SHUTDOWNS WITH BUILDING/MANAGEMENT. 2. MECHANICAL HVAC CONTRACTOR SHALL PERFORM A FIELD SURVEY PRIOR TO COMMENCING WITH DEMOLITION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND FOR DIRECTION PRIOR TO COMMENCING WITH DEMOLITION. 3. ANY EXISTING SYSTEMS AND/OR EQUIPMENT NOTED AS EXISTING TO REMAIN SHALL BE FIELD VERIFIED FOR DEFICIENCIES. NOTIFY ARCHITECT AND ENGINEER OF ANY DEFICIENCIES DISCOVERED. 4. EXISTING EQUIPMENT TO BE RELOCATED SHALL BE INSPECTED PRIOR TO RELOCATION. NOTIFY ARCHITECT AND ENGINEER OF ANY DEFICIENCIES DISCOVERED. 5. PROJECT SCOPE INVOLVES REMOVAL AND MODIFICATION TO CONDENSER WATER PIPING SYSTEM. CONTRACTOR SHALL ISOLATE/SHUTOFF SYSTEM AND DRAIN (AND PROPERLY DISPOSE) TO ACCOMMODATE SCOPE OF WORK. 6. MECHANICAL HVAC CONTRACTOR SHALL REFER TO ALL SHEETS CONTAINED IN DRAWING SET FOR COMPLETE SCOPE OF WORK. TYPICAL DETAILS, INSTALLATION REQUIREMENTS AND GENERAL BUILDING STANDARDS ARE REFERENCED AND APPLICABLE TO THESE CONTRACT DOCUMENTS. 7. CODED NOTE NUMBERS USED/NOT USED FOR CONSISTENCY BETWEEN SHEETS. 8. IT IS THE INTENT TO REUSE DUCTWORK WHERE PRACTICAL. CONTRACTOR MAY REUSE DUCT TAPS OF EQUAL SIZE. ANY EXISTING CONDITIONS THAT VARY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR TO FABRICATION OR INSTALLATION OF NEW HVAC SYSTEMS. RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes IC'Itp at Caimal ntro DATE: 02/23/18 • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (PN. ?1A Qn1 A711 Mechanical HVAC Piping Plan SCALE: ,,$„ _ E: MECHANICAL HVAC PIPING PLAN CODED NOTES: XX 0 NEW LOCATION FOR RELOCATED HEAT PUMP. EXTEND CONDENSER WATER AND CONDENSATE PIPING AS REQUIRED FOR NEW LOCATION. O2 CONNECT TO EXISTING CONDENSER WATER. FIELD VERIFY EXACT LOCATION AND ROUTING. N H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Mechanical HVAC Piping Plan No. M-4.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: 1/8" = V-0" Drawing: Mechanical HVAC Piping Plan No. M-4.04 HVAC SPECIFICATIONS 1. GENERAL PROVISIONS A. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, ALTERNATES, ADDENDA'S', AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. CONTRACTORS AND SUBCONTRACTORS SHALL EXAMINE SAME AS WELL AS OTHER DIVISIONS OF THE SPECIFICATIONS WHICH AFFECT WORK UNDER THIS DIVISION. B. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, SERVICES, AND SHALL PERFORM ALL WORK COMPLETE AND IN STRICT ACCORDANCE WITH THIS SPECIFICATION AND APPLICABLE DRAWINGS. ANY DEVIATIONS SHALL BE CLEARLY DEFINED AND ITEMIZED IN ACCORDANCE WITH SECTION 101 OF THIS SPECIFICATION. C. THIS CONTRACTOR IS INSTRUCTED TO READ CAREFULLY THE SPECIFICATIONS FOR ALL PARTS OF THE WORK, WHICH INCLUDE THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION, CIVIL, STRUCTURAL AND ALL OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS THAT ARE PART OF THE CONTRACT DOCUMENTS. D. ALL ITEMS OF LABOR, MATERIAL, AND EQUIPMENT NOT SPECIFICALLY MENTIONED HEREIN OR SHOWN ON PLAN, BUT INCIDENTAL TO, OR REQUIRED FOR THE COMPLETE INSTALLATION AND PROPER OPERATION OF THE WORK, SHALL BE FURNISHED AS IF CALLED FOR IN DETAIL BY THE SPECIFICATIONS OR DRAWINGS. E. AS USED IN THIS SPECIFICATION, "PROVIDE" MEANS "FURNISH AND INSTALL,. "FURNISH" MEANS "TO PURCHASE AND DELIVER TO THE PROJECT SITE COMPLETE WITH EVERY NECESSARY APPURTENANCE AND SUPPORT," AND "INSTALL" MEANS "TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND PERFORM EVERY OPERATION NECESSARY FOR PROPER INSTALLATION PER CODES AND MANUFACTURERS REQUIREMENTS, TO ESTABLISH SECURE MOUNTING AND CORRECT OPERATION AT THE PROPER LOCATION IN THE PROJECT." 2. PERMITS, CODES, INSPECTIONS AND TESTS. A. THE HVAC CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED FOR THE PROSECUTION OF HVAC WORK. ALL PERMITS AND CERTIFICATES OF INSPECTION AND APPROVAL SIGNED BY THE CONTROLLING BUILDING DEPARTMENT SHALL BECOME PROPERTY OF THE OWNER B. DRAWINGS INDICATE THE MINIMUM DESIGN REQUIREMENTS. NATIONAL, STATE, AND LOCAL CODES SHALL BE FOLLOWED, COMPLY WITH THE LATEST EDITIONS OF THE STATE MECHANICAL CODE, NFPA, SMACNA, AND ASHRAE STANDARDS. THE CONTRACTOR SHALL INCLUDE THE COST OF SATISFYING SUCH CODES AND STANDARDS IN THE BID. C. FOLLOWING COMPLETION OF THE HVAC WORK, FURNISH TO THE OWNER, IN DUPLICATE, CERTIFICATES OF INSPECTION AND APPROVAL BY REGULATORY AGENCIES HAVING JURISDICTION. (1) DEMONSTRATE TO THE OWNER'S SATISFACTION THE PROPER OPERATION OF EACH OF THE SYSTEMS COMPRISING THIS CONTRACT BEFORE FINAL PAYMENT. (2) IMMEDIATELY CORRECT ANY WORK FOUND AT VARIANCE WITH THESE SPECIFICATIONS, THE NATIONAL, STATE, AND LOCAL CODES, AND REQUIREMENTS OF GOVERNING REGULATORY AGENCIES. (3) TEST PIPING FOR LEAKS: REPAIR LEAKS IN COPPER TUBING BY SWEATING OUT JOINT; THOROUGHLY CLEANING BOTH TUBE AND FITTING, AND RESOLDERING. CORRECT LEAKS IN SCREWED JOINT BY REPLACING THREAD OR FITTING OR BOTH. (4) PROVIDE SERVICES OF A CERTIFIED A.A.B.C. OR N.E.E.B. TEST AGENCY. CONDUCT ALL TESTS IN ACCORDANCE WITH ASSOCIATED AIR BALANCE COUNCIL STANDARDS. TEST AND ADJUST AIR HANDLING SYSTEM TO WITHIN 5% OF DESIGN REQUIREMENTS. 3. VISIT TO THE SITE A. THE CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH ALL CONDITIONS AFFECTING THE WORK. THE SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE KNOWLEDGE OF ALL SUCH CONDITIONS AND NO ADDITIONAL COMPENSATION SHALL BE ALLOWED WHERE EXTRA LABOR OR MATERIALS ARE REQUIRED BECAUSE OF IGNORANCE OF THESE CONDITIONS.. 4. PROTECTION A. THE HVAC CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION FROM DIRT AND WATER DURING CONSTRUCTION NECESSITATED BY HVAC WORK. PROTECTION METHODS ARE SUBJECT TO APPROVAL BY THE ARCHITECT. 5. EQUIPMENT AND MATERIALS A. ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND SHALL CONFORM TO UNDERWRITERS' LABORATORIES STANDARDS, WHERE APPLICABLE. WHERE SPECIFICATIONS DESCRIBE, OR PLANS SHOW, MATERIALS OR EQUIPMENT OF HIGHER QUALITY THAN REQUIRED BY CODE AND LOCAL RULING, THE DRAWINGS AND SPECIFICATIONS SHALL GOVERN THE QUALITY OF THE MATERIAL OR EQUIPMENT. USED EQUIPMENT OR MATERIALS ARE PROHIBITED UNLESS NOTED OTHERWISE. B. NEW OR EXISTING TO REMAIN EQUIPMENT SHALL NOT BE OPERATED DURING CONSTRUCTION. HVAC CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AND PROVIDE TEMPORARY SPACE CONDITIONING IN ORDER TO MAINTAIN TEMPERATURES AND HUMIDITY LEVELS AS REQUIRED FOR GENERAL CONSTRUCTION. C. THE CONTRACTOR SHALL SUBMIT PROOF, IF REQUESTED BY THE OWNER, THAT THE MATERIALS, APPLIANCES, EQUIPMENT OR DEVICES FURNISHED AND INSTALLED UNDER THIS CONTRACT MEET THE REQUIREMENTS OF THE UNDERWRITERS' LABORATORIES, INC. IN REGARDS TO FIRE AND CASUALTY HAZARDS. THE LABEL OF OR LISTING BY THE UNDERWRITERS' LABORATORIES, INC. WILL BE ACCEPTED AS CONFORMING TO THIS REQUIREMENT. IN LIEU OF THE LABEL OR LISTING, THE CONTRACTOR MAY SUBMIT INDEPENDENT PROOF SATISFACTORY TO THE ARCHITECT THAT THE MATERIAL, APPLIANCES OR DEVICES CONFORM TO THE PUBLISHED STANDARDS, INCLUDING METHODS OF TEST FOR THE UNDERWRITERS' LABORATORIES INCORPORATED. UNDERWRITERS LABORATORIES, INC. AND ITS PUBLICATIONS WILL BE REFERRED TO HEREINAFTER BY THE ABBREVIATION UL. WITH OR WITHOUT ADDITIONAL IDENTIFYING SYMBOLS. 6. GUARANTEE A. THE HVAC CONTRACTOR SHALL GUARANTEE FOR A PERIOD OF ONE YEAR THAT ALL WORK AND EQUIPMENT WILL REMAIN FREE FROM ALL DEFECTS IN WORKMANSHIP AND MATERIALS, AND THAT IT WILL COMPLY WITH ALL THE SPECIFIC REQUIREMENTS OF THE SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS GOVERNING THE WORK. B. ALL WORK FOUND BY THE ENGINEER TO BE DEFECTIVE WILL BE REPLACED WITH NEW WORK MEETING ALL THE REQUIREMENTS OF THE CONTRACT. THE HVAC CONTRACTOR WILL BEAR ALL COSTS OF SUPPLYING SUCH NEW, AND INSTALLING AND FINISHING SAME, AND WILL ASSUME ALL COSTS FOR REPLACING OTHER WORK DAMAGED BY THE REMOVAL AND REPLACEMENT OF ANY OF THE WORK. THE HVAC CONTRACTOR WILL BEAR ALL COSTS FOR FREIGHT, DRAYAGE AND DEMURRAGE, AND ALL LABOR IN CONNECTION THEREWITH. 7. CUTTING, PATCHING, FIRESTOPPING AND PAINTING A. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING ALL HOLES REQUIRED FOR INSTALLATION OF HVAC WORK. HOLES SHALL BE CUT IN A NEAT MANNER SATISFACTORY TO THE ARCHITECT. B. CONTRACTOR SHALL EMPLOY AN BUILDING OWNER APPROVED ROOFING CONTRACTOR FOR ALL ROOF PENETRATIONS. ROOF SHALL BE REPAIRED SO AS NOT TO VOID ROOF WARRANTY. C. UNLESS NOTED OTHERWISE, ALL HOLES OR DAMAGE CAUSED BY THE REMOVAL OF EXISTING WORK OR THE INSTALLATION OF NEW WORK SHALL BE PROPERLY PATCHED BY THIS CONTRACTOR. HOLES SHALL BE NEATLY PATCHED AND PAINTED WITH SUITABLE MATERIAL TO MATCH EXISTING SURFACES. HOLES THROUGH FLOORS OR FIRE WALLS SHALL BE SEALED WITH THE APPROPRIATE INTUMESCENT CAULK, PUTTY, STRIP OR SHEET FIRE BARRIER PRODUCT. D. FIRESTOP SYSTEM (REQUIRED FIRESTOPPING MATERIALS) SHALL BE DETERMINED BY THE WALL OR FLOOR/CEILING ASSEMBLY AND PENETRATION TYPE AND SHALL BE UL LISTED AND TESTED IN ACCORDANCE WITH ASTM E814, FIRE RATING OF THE FIRESTOP SYSTEM SHALL BE EQUIVALENT TO THE ASSEMBLY WHICH IS PENETRATED. E. ACCEPTABLE FIRE BARRIER PRODUCTS: HILTI "FS -ONE" NELSON FLAMESEAL" OR APPROVED EQUAL AS MANUFACTURED BY 3M. 8. CLEANING AND PAINTING A. CLEAN NEW PIPING AFTER WORK IS COMPLETE TO REMOVE PIPE DOPE. LOOSE MILL SCALE, AND OTHER EXTRANEOUS MATERIALS. B. TOUCH UP AND REPAIR ANY DAMAGED FACTORY FINISHES ON EQUIPMENT AND MATERIALS FURNISHED. OTHER PAINTING WILL BE DONE UNDER THE PAINTING DIVISION OF THE SPECIFICATIONS. C. ALL EXISTING AIR DISTRIBUTION DEVICES THAT ARE TO BE REUSED SHALL BE CLEANED WITH MILD SOAP AND WATER SOLUTION AND THOROUGHLY DRIED. D. ALL EXISTING TO REMAIN HVAC SYSTEMS SHALL BE CLEANED PER CURRENT NATIONAL AIR DUCT CLEANING ASSOCIATION GENERAL SPECIFICATIONS. 9. COORDINATION AND CONDUCT OF WORK A. HVAC DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT, APPROXIMATE SIZES, GENERAL LOCATIONS OF EQUIPMENT AND PIPING. VERIFY DIMENSIONS IN FIELD; ADJUST TO MANUFACTURER'S SHOP DRAWINGS. DO NOT SCALE DRAWINGS. B. ALL REQUESTS FOR INFORMATION SUPPLEMENTAL TO THE CONSTRUCTION DOCUMENTS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT FOR DISTRIBUTION TO THE APPROPRIATE PARTY(S). C. DRAWINGS AND SPECIFICATIONS ARE TO BE CONSIDERED AS SUPPLEMENTING EACH OTHER. WORK SPECIFIED BUT NOT SHOWN, OR SHOWN BUT NOT SPECIFIED, SHALL BE PERFORMED OR FURNISHED AS THOUGH MENTIONED IN BOTH SPECIFICATIONS AND DRAWINGS. D. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER. E. ARCHITECTURAL AND STRUCTURAL DRAWINGS SUPERSEDE HVAC DRAWINGS. DETERMINE THAT WORK OF THIS DIVISION CAN BE ACCOMMODATED WITHIN SPACES PROVIDED. NOTIFY ARCHITECT OF ANY INTERFERENCE BEFORE STARTING INSTALLATION. F. DETERMINE SIZES, LOCATIONS FOR CHASES AND OPENINGS NECESSARY FOR INSTALLATION OF HVAC WORK, COOPERATE WITH OTHER TRADES IN PROVIDING SLEEVES, INSERTS AND HANGERS. G. COORDINATE THIS WORK WITH ALL TRADES. ARRANGE OPERATIONS SO AS NOT TO DELAY COMPLETION OF INSTALLATION OF ANY PARTS OF INTERRELATED WORK SO THAT CONSTRUCTION MAY PROCEED ON SCHEDULE. H. COOPERATE WITH ALL TRADES IN PREPARING INTERFERENCE DRAWINGS FOR AREAS WHERE THERE IS POSSIBLE CONFLICT BETWEEN TRADES. EXACT LOCATION OF PIPES, DUCTS AND EQUIPMENT SHALL BE BASED ON FIELD MEASUREMENT WITH FINAL ARRANGEMENT DETERMINED BY INTRA -TRADE AGREEMENTS SUBJECT TO ARCHITECT'S APPROVAL. I. ARCHITECT RESERVES THE RIGHT TO MAKE REASONABLE CHANGES IN INDICATED LOCATIONS WITHOUT EXTRA COST TO THE OWNER. J. ALL WORK SHALL BE INSTALLED IN NEAT AND WORKMANLIKE MANNER BY FIRST-CLASS MECHANICS. THE CONTRACTOR SHALL PROVIDE ADEQUATE AND COMPETENT SUPERVISION OF THE JOB AS REQUIRED. K. DUCTWORK, PIPING AND EQUIPMENT SHALL BE ARRANGED SUBSTANTIALLY AS INDICATED. ANY CHANGE RESULTING IN A SAVINGS IN LABOR OR MATERIAL SHALL BE MADE ONLY IN ACCORDANCE WITH A CONTRACT CHANGE ORDER. DEVIATIONS SHALL BE MADE ONLY WHERE NECESSARY TO AVOID INTERFERENCES AND ONLY AFTER DRAWINGS SHOWING THE PROPOSED DEVIATIONS HAVE BEEN SUBMITTED TO AND APPROVED BY THE ARCHITECT. L. COORDINATE ALL SHUTDOWNS OF ANY HVAC SYSTEM IN ADVANCE WITH THE OWNER. 10. SUBMITTALS A. PROVIDE A MINIMUM OF SIX (6) SETS OF SHOP DRAWINGS/SUBMITTALS FOR ALL SCHEDULED AND/OR SPECIFIED EQUIPMENT FOR APPROVAL BY THE ARCHITECT AND ENGINEER. INFORMATION SHALL INCLUDE, BUT IS NOT LIMITED TO; CFM, HP, GPM, MBH, EER, COP, %EFF, VOLTAGE/PHASE, MCA, CONNECTION SIZES, WEIGHT, DIMENSIONS, SCHEDULED EQUIPMENT, DIFFUSERS, DAMPERS, LISTED ACCESSORIES, ETC. AND OTHER COMPONENTS REQUIRED FOR A COMPLETE INSTALLATION. B. WHERE ONLY ONE MAKE OF EQUIPMENT IS NAMED, IT SHALL BE PROVIDE AS SPECIFIED. C. VERBAL REQUESTS OF APPROVALS FOR ANY SUBSTITUTION WILL NOT BE BINDING ON THE ARCHITECT, ENGINEER AND OWNER. RELEASED IFCR CONSTRUCTION Subject to aompdiianice with ®III regofatiens of State and ILonal Endes ICltp of Caimal DATE: 02/23/18 a, . .1t�0t D. THIS CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR ALL COSTS FOR REDESIGN AND CHANGES NECESSARY BY ALL TRADES TO ACCOMMODATE THE USE OF EQUIPMENT NOT SPECIFIED ON PROJECT DOCUMENTS. E. BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVES. DRAWINGS AND SPECIFICATIONS ARE BASED ON THE PRODUCTS SPECIFIED BY TYPE, MODEL, AND SIZE, AND THUS ESTABLISH MINIMUM QUALITIES, WHICH SUBSTITUTES MUST MEET TO QUALIFY FOR REVIEW. F. SHOULD THE CONTRACTOR PROPOSE TO FURNISH MATERIALS, EQUIPMENT, AND DEVICES, OTHER THAN THOSE SPECIFIED AND LISTED. THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR SUBSTITUTIONS TO THE ENGINEER AT LEAST FOURTEEN (14) CALENDAR DAYS PRIOR TO BID OPENING. THE REQUEST SHALL BE AN ALTERNATE TO THE ORIGINAL BID AND SHALL INCLUDE AND BE ACCOMPANIED WITH COMPLETE SPECIFICATION CUT SHEET SUBMITTALS AS OUTLINED IN SECTION 10.A OF THIS SPECIFICATION SECTION, COMPLETE WITH DESCRIPTIVE (MANUFACTURER, BRAND NAME, CATALOG NUMBER, ETC) AND TECHNICAL DATA FOR ALL ITEMS. INDICATE ANY ADDITIONS OR DEDUCTIONS TO THE CONTRACT PRICE ON BOTH THE SUBSTITUTION SUBMITTAL AND THE BID FORM. FAILURE TO PERFORM THESE ACTIONS EQUATES TO ACKNOWLEDGEMENT THAT THE PROJECT HAS BEEN BID WITH STRICT ACCORDANCE TO THIS SPECIFICATION AND APPLICABLE DRAWINGS. G. ACCEPTANCE OR REJECTION OF THE PROPOSED SUBSTITUTIONS SHALL BE SUBJECT TO APPROVAL OF THE ARCHITECT AND ENGINEER. IF REQUESTED, THE CONTRACTOR SHALL SUBMIT INSPECTION SAMPLES OF BOTH THE SPECIFIED AND THE PROPOSED SUBSTITUTE ITEMS. H. IF ANY SUBSTITUTIONS ARE APPROVED, AN ADDENDUM LISTING THE APPROVED ITEMS(S) WILL BE ISSUED TO ALL BIDDING CONTRACTORS PRIOR TO THE BID DATE. I. IN ALL CASES WHERE SUBSTITUTIONS ARE PERMITTED, THE CONTRACTOR SHALL BEAR ANY EXTRA COST OF EVALUATING THE EQUALITY OF THE MATERIAL AND EQUIPMENT TO BE INSTALLED. 11. EQUIPMENT IDENTIFICATION A. THE CONTRACTOR SHALL FURNISH AND INSTALL A SYSTEM OF NAMEPLATES DESIGNED TO IDENTIFY EACH PIECE OF EQUIPMENT. (1) NAMEPLATE LETTERS AND NUMBERS SHALL MATCH EQUIPMENT DESIGNATION AS INDICATED ON THE DRAWINGS. (2) NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH BLACK SURFACE AND WHITE CORE. USE 1/16" THICK MATERIAL FOR PLATES UP TO 2" BY 4". FOR LARGER SIZES USE 1/8" THICK. LETTERS AND NUMBERS SHALL BE A MINIMUM OF X" HIGH. (3) FASTEN NAMEPLATES TO ALL EQUIPMENT BY THE USE OF STAINLESS STEEL SHEET METAL SCREWS. 12. AS -BUILT DRAWINGS A. AS WORK PROGRESSES, RECORD ON A SET OF "AS -BUILT' PRINTS ANY DEVIATIONS FROM DESIGN DRAWINGS. DELIVER THIS SET TO THE OWNER BEFORE SUBMITTING REQUEST FOR FINAL PAYMENT. THE "AS -BUILT' PRINTS SHALL BE AN ACCURATE DEPICTION OF THE PROJECT AS COMPLETED. 13. OPERATING AND MAINTENANCE MANUALS A. PROVIDE TO OWNER AT PROJECT TURNOVER, THREE (3) HARDBOUND COPIES OF OPERATING AND MAINTENANCE MANUALS FOR ALL EQUIPMENT AND SYSTEMS INSTALLED. B. MANUALS SHALL INCLUDE ALL RELEVANT INFORMATION NEEDED FOR DAY-TO-DAY OPERATION AND MANAGEMENT OF EACH SYSTEM AND EQUIPMENT MAINTENANCE INFORMATION REQUIRED TO SUPPORT THE MAINTENANCE PROGRAM. C. MANUALS SHALL INCLUDE THE SEQUENCE OF OPERATION FOR EACH SYSTEM WHICH DESCRIBES THE CONTROL COMPONENTS AND HOW THE SYSTEM WILL START, STOP AND OPERATE. 14. INSULATION A. PROVIDE ALL INSULATION MATERIALS (INSULATION, JACKETS, FITTING COVERS, ADHESIVES, CEMENTS, MASTICS, SEALERS AND FINISHES) WITH A FLAME -SPREAD INDEX OF 25 OR LESS AND SMOKE DEVELOPED INDEX OF 50 OR LESS. AS TESTED UNDER PROCEDURE ASTM E-84 (NFPA 255) B. ALL INSULATION SHALL BE INSTALLED OVER CLEAN, DRY SURFACES. INSULATION MUST BE DRY AND IN GOOD CONDITION. WET OR DAMAGED INSULATION IS NOT ACCEPTABLE. NO INSULATION SHALL BE APPLIED PRIOR TO PRESSURE TEST COMPLETION OF THE RESPECTIVE SYSTEM. C. ALL INSULATION SHALL BE CONTINUOUS (INCLUDING VAPOR BARRIER) THROUGH WALL AND CEILING OPENINGS AND SLEEVES. OVERLAP AT SEAMS PER MANUFACTURER'S RECOMMENDATIONS. D. ALL INSULATION PRODUCTS SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATION. THE WORKMANSHIP SHALL BE FIRST CLASS AND ALL JOINTS SHALL BE MADE TIGHT. E. INSULATION MUST MEET ADOPTED ASHRAE 90.1 STANDARDS. E. INSULATE CONCEALED SUPPLY AIR DUCTWORK WITH 2" THICK OWENS-CORNING FIBERGLASS DUCTWRAP WITH FOIL FACED ALL -SERVICE JACKET. F. INSULATE SUPPLY AIR DUCTWORK LOCATED IN PLENUM SPACES WITH 1-1/2" THICK OWENS-CORNING FIBERGLASS DUCTWRAP WITH FOIL FACED ALL -SERVICE JACKET. G. INSULATE OUTDOOR AIR DUCTWORK WITH 1-1/2" THICK OWENS-CORNING FIBERGLASS DUCTWRAP WITH FOIL FACED ALL -SERVICE JACKET. H. INTERNAL DUCT INSULATION SHALL BE USED ON EXPOSED DUCTWORK. I. INSULATE SUPPLY AIR DUCTWORK DOWNSTREAM OF DUCT TERMINAL UNITS WITH 1-1/2" THICK OWENS-CORNING FIBERGLASS DUCTWRAP WITH FOIL FACED ALL -SERVICE JACKET. J. REPAIR EXISTING INSULATION WHERE REMOVED FOR NEW CONNECTIONS OR INSULATION DAMAGED DURING CONSTRUCTION. INSULATION SHALL BE THE SAME AS SPECIFIED FOR NEW SERVICE. K. ALL INSULATION USED AS PLENUM WRAP COVERING FOR COMBUSTIBLE MATERIALS IN A PLENUM SPACE SHALL BE 3M PLENUM PROTECTION SYSTEM (PP -100-P), ONE LAYER OF 3M FIRE BARRIER DUCT WRAP 5A, IN ACCORDANCE WITH UL910 & UL1887. L. ACOUSTICAL DUCT LINING: (1) INTERNALLY LINE FIRST TEN FEET OF DUCTWORK FROM AIR HANDLERS AND TERMINAL UNITS AND WHERE INDICATED ON PLANS. (2) FIBROUS GLASS, COMPLYING WITH THERMAL INSULATION MANUFACTURERS ASSOCIATION (TIMA) AHC -101. (3) ASTM C 1071, TYPE II, WITH COATED SURFACE EXPOSED TO AIRSTREAM TO PREVENT EROSION OF GLASS FIBERS 1" THICK. 1- � LB. DENSITY. COATING MATERIAL SHALL BE ANTI -MICROBIAL AND COMPLY WITH NFPA 90A AND 90B. (4) K-FACTOR"EQUAL TO 0.28 OR BETTER, AT MEAN TEMPERATURE OF 75 DEG. F. (5) FLAME SPREAD INDEX SHALL BE 25 OR LESS AND SMOKE DEVELOPED INDEX SHALL BE 50 OR LESS, AS TESTED IN ACCORDANCE WITH ASTM C 411. (6) DUCT LINING ADHESIVE SHALL COMPLY WITH ASTM C 916 SPECIFICATIONS FOR ADHESIVES FOR "DUCT THERMAL INSULATION". DUCT LINING FASTENERS ALL COMPLY WITH SMACNA DUCT CONSTRUCTION STANDARDS, ARTICLE S2.11 (7) ALTERNATE DUCT LINING MATERIAL - ARMACELL AP ARMAFLEX SA BLACK DUCT LINER, 3/4" THICK, MICROBAN ANTI -MICROBIAL PROTECTION. 15. METAL DUCTWORK A. HVAC CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO FABRICATION OF DUCTWORK. ANY CONFLICTS OR INTERFERENCES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. B. GALVANIZED DUCTWORK SHALL BE FABRICATED OF NO.1 PRIME GALVANIZED SHEET METAL OF LOCK FORMING QUALITY. C. SEALING MATERIALS SHALL BE SUITABLE FOR; USE WITH AIR DISTRIBUTION DUCTWORK. ACCEPTABLE MANUFACTURERS ARE MONOCO INDUSTRIES, 3M, OR UNITED SHEET METAL. D. PROVIDE ALL DUCTWORK AS INDICATED ON THE DRAWINGS, MAKING ALL NECESSARY OFFSETS (WHETHER OR NOT SPECIFICALLY INDICTED) AS REQUIRED TO MEET THE VARIOUS BUILDING CONDITIONS. DUCTWORK INSTALLATION SHALL NOT CONFLICT WITH EQUIPMENT OR PIPING. E. EXPOSED DUCTWORK SHALL BE PRIMED AND PAINTED. COORDINATE WITH ARCHITECTURAL PLANS FOR COLOR SELECTION. F. ALL CHANGES IN CROSS SECTION SHALL BE MADE WITHOUT REDUCING THE DESIGN AREA OF THE DUCT OR RAISING THE PRESSURE DROP PER 100 FEET OF DUCT SHOWN ON DOCUMENTS. G. NO PIPE OR OTHER OBSTRUCTIONS SHALL PASS THROUGH AIR DUCTS, UNLESS SPECIFICALLY SHOWN ON PLANS. H. CAP ALL OPEN ENDS TO DUCTWORK DURING CONSTRUCTION TO PREVENT ENTRANCE OF DUST, DEBRIS, MOISTURE ETC. I. INSTALL DUCTWORK RUN ABOVE CEILING AS HIGH AS POSSIBLE SO AS TO MAINTAIN DESIGN CEILING HEIGHTS. EXPOSED DUCTWORK SHALL BE INSTALLED TO PROVIDE MAXIMUM HEADROOM OR AT HEIGHT SPECIFIED ON PLANS. J. DUCTWORK SHALL NOT BE HUNG FROM EQUIPMENT, PIPING, CONDUIT, ROOF DECKING OR OTHER DUCTWORK. K. ALL DUCTWORK JOINTS AND SEAMS SHALL BE AIR -TIGHT PER SMACNA TABLE 1.1. POORLY MADE JOINTS, SPLITS, VISIBLE HOLES AT CORNERS, ETC SHALL BE REWORKED AND REPAIRED. WHERE EXCESSIVE PULSATING OF DUCTWORK IS FOUND, ADDITIONAL STIFFENERS SHALL BE ADDED. ANY CRACKING IN THE SEALANT THAT IS APPARENT UPON INSPECTION SHALL BE SUFFICIENT TO WARRANT REJECTION. L. IF THE INTERIOR OF SHEET METAL IS EXPOSED TO VIEW THROUGH AIR DISTRIBUTION DEVICES IN FINISHED AREAS OF THE BUILDING, IT SHALL BE COATED WITH PRIMER AND A FLAT BLACK FINISH COAT. M. ALL DUCTWORK SHALL BE SUPPORTED PER SMACNA REQUIREMENTS. N. RECTANGULAR DUCTWORK FITTINGS. (1) BRANCH CONNECTIONS SHALL BE 45 DEGREES ENTRY. STRAIGHT TAPS ARE NOT PERMITTED. (2) CHANGES IN DIRECTION SHALL BE MADE WITH FULL RADIUS ELBOWS WITH RADIUS EQUAL TO 1-1/2 TIMES THE HORIZONTAL WIDTH OF THE DUCT OR WITH SQUARE ELBOWS WITH TURNING VANES. TURNING VANES SHALL BE DOUBLE THICKNESS TYPE CONSTRUCTED OF THE SAME MATERIAL AS THE SURROUNDING DUCTWORK, PER SMACNA REQUIREMENTS. 0. ROUND DUCTWORK FITTINGS: (1) BRANCH CONNECTIONS SHALL BE MADE WITH 45 DEGREE ENTRY TEES. (2) CHANGE IN DIRECTION SHALL BE MADE WITH FULL RADIUS ELBOWS WITH RADIUS EQUAL TO 1-1/2 TIMES THE DIAMETER OF THE DUCT. P. LOW PRESSURE DUCTWORK SHALL BE CONSTRUCTED PER SMACNA "HVAC DUCT CONSTRUCTION STANDARDS"FOR 2 INCH STATIC PRESSURE, SEAL CLASS "B". Q. HANGERS AND SUPPORTS (1) PROVIDE GALVANIZED STEEL STRAPS, ALL -THREAD ROD AND HORIZONTAL ANGLE SUPPORTS SIZED PER SMACNA REQUIREMENTS. (2) DUCT ATTACHMENTS SHALL BE MADE USING SHEET METAL SCREWS COMPATIBLE WITH DUCT MATERIALS. (3) BUILDING ATTACHMENTS SHALL BE CONCRETE INSERTS OR STRUCTURAL STEEL FASTENERS APPROPRIATE FOR THE BUILDING MATERIALS. DO NOT USE POWER ACTIVATE CONCRETE FASTENERS. "C TYPE MALLEABLE IRON BEAM CLAMPS ARE ACCEPTABLE ONLY IF USED WITH CARBON STEEL RETAINER STRAP. 16. FLEXIBLE DUCTWORK A. TESTED AND CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. AS CLASS I AIR DUCT AND LABELED IN ACCORDANCE WITH U.L. 181, STANDARD FOR AIR DUCTS". THE FLAME SPREAD RATING SHALL BE 25 OR LESS AND THE SMOKE DEVELOPED RATING SHALL BE 50 OR LESS. B. LINER SHALL BE CONSTRUCTED OF ALUMINUM FOIL, FIBERGLASS AND ALUMINIZED POLYESTER, MECHANICALLY LOCKED WITHOUT ADHESIVES, HELIX SHALL BE GALVANIZED STEEL, FORMED AND MECHANICALLY LOCKED TO FABRIC. C. WHERE DUCTWORK IS TO BE INSULATED, FLEXIBLE DUCTWORK LINER SHALL BE COVERED BY A FACTORY WRAPPED, 1-1/2" THICK, 3/4 POUND DENSITY FIBERGLASS INSULATION BLANKET WITH A FIRE RETARDANT REINFORCED ALUMINUM OUTER JACKET. D. INSTALL FLEXIBLE DUCTWORK FULLY EXTENDED, FREE OF SAGS AND KINKS. MAXIMUM LENGTH OF FLEXIBLE DUCTWORK SHALL BE 3'-0". FASTEN FLEXIBLE DUCTWORK TO RIGID DUCTWORK AND DEVICES WITH SELF-LOCKING 100 PERCENT NYLON, ADJUSTABLE DIAMETER CLAMPS. E. ACCEPTABLE MANUFACTURERS ARE THERMAFLEX, FLEXMASTER U.S.A. INC. AND CLEVAFLEX. 17. BALANCING DAMPERS A. PROVIDE BALANCING DAMPERS FOR ALL AIR TERMINAL DEVICES (SUCH AS BUT NOT LIMITED TO, DIFFUSERS, REGISTERS, GRILLES, ETC.) AND BRANCH DUCTWORK REQUIRED FOR PROPER BALANCING OF SYSTEM. B. ROUND DAMPERS SHALL BE SINGLE BLADE TYPE CONSTRUCTION, MINIMUM 18 GAUGE GALVANIZED STEEL. PIVOT ROD SHAFT SHALL BE CONTINUOUS. C. RECTANGULAR DAMPERS SHALL BE SINGLE BLADE OR MULTIPLE (OPPOSED BLADE) TYPE CONSTRUCTION. MAXIMUM BLADE WIDTH IS 8 INCHES. D. ALL BALANCING DAMPERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS" E. FURNISH ALL BALANCING DAMPERS WITH YOUNG REGULATOR COMPANY VALCALOX REGULATORS WITH HANDLE PERMANENTLY ATTACHED. DAMPER HANDLE POSITION SHALL BE SECURELY LOCKED IN PLACE BY TIGHTENING OF A LOCK NUT. WHERE DUCTWORK IS EXTERNALLY INSULATED, REGULATOR BASE HEIGHT SHALL ACCOMMODATE INSULATION THICKNESS. F. PROVIDE ALL MANUAL BALANCING DAMPERS WHERE INDICATED ON THE DRAWINGS AND WHERE NECESSARY TO PROPERLY DISTRIBUTE AND BALANCE THE AIR. 18. REGISTERS, GRILLES AND DIFFUSERS A. PROVIDE REGISTERS, GRILLS AND DIFFUSERS WHERE SHOWN ON THE DRAWINGS, OF SIZE TYPE, AND MATERIAL AS INDICATED AND AS REQUIRED FOR A COMPLETE INSTALLATION. B. BORDER TYPES SHALL BE COMPATIBLE WITH THE CEILINGS WHERE THE GRILLES AND DIFFUSERS ARE TO BE INSTALLED. C. ALL GRILLES AND DIFFUSERS SHALL BE FINISHED WITH A FACTORY APPLIED OFF-WHITE FINISH UNLESS NOTED OTHERWISE. D. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF GRILLES AND DIFFUSERS. 19. VIBRATION ISOLATION A. PROVIDE ADEQUATE VIBRATION ISOLATION FOR EACH PIECE OF EQUIPMENT. B. PROVIDE FLEXIBLE CONNECTIONS WITH 1" SLACK BETWEEN DUCTS AND FANS AS MANUFACTURED BY DURO-DYNE, OR EQUIVALENT. C. PROVIDE FLEXIBLE FITTING ON PIPING CONNECTIONS TO EQUIPMENT. 20. REFRIGERATION AND AIR CONDITIONING CONDENSATE PIPING SYSTEMS A. USE TYPE DWV COPPER PIPING WITH BRAZED DRAINAGE FITTINGS FOR CONDENSATE PIPING. B. USE TYPE ACR COPPER PIPING WITH BRAZED WROUGHT COPPER FITTINGS FOR ALL REFRIGERATION PIPING. C. PITCH PUMPED AND GRAVITY CONDENSATE PIPING AT 1/8 INCH PER FOOT IN DIRECTION OF FLOW. D. INSULATE ALL INTERIOR CONDENSATE PIPING AND REFRIGERATION SUCTION PIPING WITH 3/4 INCH ARMACELL CLOSED CELL SELF SEALING ARMAFLEX INSULATION. 21. HVAC PIPING A. CONDENSER WATER PIPING AND FITTINGS SHALL BE TYPE L HARD COPPER PIPE WITH WROUGHT COPPER SOLDER JOINT FITTINGS THRU 1.5" PIPE SIZES. PIPING 2" AND LARGER SHALL BE SCHEDULE 10 BLACK STEEL VICTAULIC PIPING WITH MECHANICAL COUPLINGS DESIGNED FOR SPECIFIC USE. B. SHUT-OFF VALVES SHALL BE BRONZE OR VICTAULIC IRON BODY, TWO PIECE, FULL PORT, LEVER HANDLE BALL VALVES WITH TEFLON SEATS, CHROME PLATED BRASS OR STEEL BALL RESPECTIVELY, STEEL OR BRASS STEM AND SOLDER OR GROOVED ENDS. RESPECTIVELY. 60D PSI WOG. C. BALANCING VALVES (1) MANUAL - BRONZE BODY, COMBINATION VENTURI AND BALL VALVE WITH TWO PRESSURE TEMPERATURE TEST PORTS, MEMORY STOP, INLET UNION CONNECTION AND THREADED ENDS, 400 PSI AT 2507. ACCEPTABLE MANUFACTURER: FLOW DESIGN INC. "FLOWSET". (2) AUTOMATIC - BRASS Y -TYPE BODY, INTEGRAL BRASS -BODY BALL VALVE WITH TWO PRESSURE TEMPERATURE TEST PORTS, OVABLE/REPLACEABLE STAINLESS STEEL FLOW CARTRIDGE AND THREADED ENDS, 400 PSI AT 250°F. ACCEPTABLE MANUFACTURER: FLOW DESIGN INC. "AUTOFLOW". D. INSTALLATION (1) INSTALL CONDENSER WATER PIPING SYSTEM AS INDICATED WITH CONNECTIONS MADE TO ALL EQUIPMENT AS SHOWN. (2) WHERE LINES ARE REDUCED IN SIZE, ECCENTRIC REDUCING FITTINGS SHALL BE USED TO ALIGN TOP OF MAINS AND PREVENT AIR POCKETS. (3) BRANCH CONNECTIONS FROM MAINS TO RISERS OR EQUIPMENT BELOW MAINS SHALL BE TAKEN FROM THE BOTTOM OF THE MAIN AND PROVIDED WITH AT LEAST THREE ELBOWS FOR EXPANSION. SUPPLY RUN -OUTS SHALL PITCH DOWN AWAY FROM MAIN 1 INCH IN 5'-0". RETURN RUN -OUTS SHALL PITCH UP TO MAIN 1 INCH IN 5-0". (4) BRANCH CONNECTIONS FROM MAINS TO RISERS OR EQUIPMENT ABOVE MAINS SHALL BE TAKEN FROM THE TOP OF MAIN AND PROVIDED WITH AT LEAST THREE ELBOWS FOR EXPANSION. SUPPLY RUN -OUTS SHALL PITCH UP AWAY FROM MAIN 1 INCH IN 5'-0". RETURN RUN -OUTS SHALL PITCH DOWN TO MAIN 1 INCH IN 5'-O". (5) INSTALL MANUAL AIR VENTS AT ALL HIGH POINTS IN THE PIPING SYSTEM WHERE INDICATED AND WHERE OTHERWISE NEEDED FOR COMPLETE AIR ELIMINATION FROM THE SYSTEM. INSTALL AIR VENTS ON THE HIGH SIDE OF ALL EQUIPMENT CONNECTIONS. (6) INSTALL DRAIN VALVES AT ALL LOW POINTS OF THE SYSTEM. (7) PROVIDE A SHUT-OFF VALVE IN THE SUPPLY TO EACH COOLING COIL, CONVECTOR, FINNED TUBE RADIATOR OR CONDENSER AND A BALANCING VALVE IN THE RETURN LINE. BALANCING DEVICE SHALL ALSO SERVE AS A SHUT-OFF VALVE. E. TESTING AND CLEANING (1) ALL CONDENSER, CHILLED WATER, HEATING HOT WATER SYSTEMS SHALL BE PRESSURE TESTED WITH WATER TO 125 PSI. TEST DURATION SHALL BE 6 HOURS. (2) CLEAN ALL SYSTEMS AS FOLLOWS: FILL SYSTEM WITH CLEAN WATER AND FLUSH; REFILL WITH CLEAN WATER/DETERGENT MIXTURE, CIRCULATE FOR AT LEAST 8 HOURS. DRAIN SYSTEM AND FLUSH WITH CLEAN COLD WATER. ADD WATER TREATMENT AT THIS TIME. 22. WATER SOURCE HEAT PUMP UNITS A. DESCRIPTION: PACKAGED WATER -SOURCE HEAT PUMP WITH TEMPERATURE CONTROLS; FACTORY ASSEMBLED, TESTED, AND RATED ACCORDING TO ARI -ISO -13256-1, ETL LISTED. B. CABINET AND CHASSIS: PAINTED STEEL CASING WITH THE FOLLOWING FEATURES: 1. ACCESS PANEL FOR ACCESS AND MAINTENANCE OF INTERNAL COMPONENTS. 2. KNOCKOUTS FOR ELECTRICAL CONNECTIONS. NO KNOCKOUTS FOR PIPING. WATER CONNECTIONS ARE FLUSH MOUNT WITHOUT REQUIRING BACKUP WRENCH. 3. HORIZONTAL FLAT TOP WITH GRILLE AND HINGED CONTROL COVER 4. CABINET INSULATION: FOIL FACED, MINIMUM � INCH THICK, COMPLYING WITH UL 181. 5. CONDENSATE DRAINAGE: (PVC) PLASTIC DRAIN PAN PITCHED AS REQUIRED IN ASHRAE 62 WITH CONDENSATE DRAIN PIPING PROJECTING THROUGH UNIT CABINET. 6. SOUND ATTENUATION PACKAGE: a. MINIMUM 0.598 -INCH -THICK COMPRESSOR ENCLOSURE AND FRONT PANEL. MINIMUM 0.0937 -INCH -THICK FOAM GASKET AROUND THE COMPRESSOR AND PERIMETER OF END PANEL. b. SOUND ATTENUATING BLANKET OVER COMPRESSOR. C. FAN: DIRECT DRIVEN, CENTRIFUGAL, WITH MULTI -SPEED MOTOR RESILIENTLY MOUNTED IN FAN INLET. 1. MOTOR: MULTI -SPEED, PERMANENTLY LUBRICATED, ECM MOTOR OR AS SCHEDULED. D. WATER CIRCUIT: 1. REFRIGERANT -TO -WATER HEAT EXCHANGERS: 25 if TO 120°F OPERATING TEMPERATURE RANGE. a. INSULATED, EXTENDED RANGE COAXIAL HEAT EXCHANGERS WITH COPPER WATER TUBE WITH ENHANCED HEAT -TRANSFER SURFACES INSIDE A STEEL SHELL; BOTH SHELL AND TUBE LEAK TESTED TO 450 PSIG ON REFRIGERANT SIDE AND 400 PSIG ON WATER SIDE. FACTORY -MOUNT HEAT EXCHANGER IN UNIT ON RESILIENT RUBBER VIBRATION ISOLATORS. E. REFRIGERANT -TO -AIR -COILS: COPPER TUBES WITH ALUMINUM FINS, LEAK TESTED TO 450 PSIG. F. REFRIGERANT CIRCUIT COMPONENTS: 1. SEALED REFRIGERANT CIRCUIT: CHARGE WITH R -410A REFRIGERANT (R-22 IS NOT ACCEPTABLE). 2. FILTER -DRYER: FACTORY INSTALLED TO CLEAN AND DEHYDRATE THE REFRIGERANT CIRCUIT. 3. CHARGING CONNECTIONS: SERVICE FITTINGS ON SUCTION AND LIQUID FOR CHARGING AND TESTING. 4. REVERSING VALVE: PILOT -OPERATED SLIDING-TYPE VALVE DESIGNED TO BE FAIL-SAFE IN HEATING POSITION WITH REPLACEABLE MAGNETIC COIL. 5. COMPRESSOR: DUAL CAPACITY SCROLL COMPRESSOR INSTALLED ON VIBRATION ISOLATORS AND HOUSED IN AN ACOUSTICALLY TREATED ENCLOSURE WITH FACTORY -INSTALLED SAFETIES AS FOLLOWS: a. DUAL CAPACITY -HEAT PUMP DUTY. b. ANTIRECYCLE TIMER. C. HIGH-PRESSURE CUTOUT. d. LOW-PRESSURE CUTOUT OR LOSS OF CHARGE SWITCH. e. INTERNAL THERMAL -OVERLOAD PROTECTION. f. FREEZESTAT TO STOP COMPRESSOR IF WATER -LOOP TEMPERATURE IN REFRIGERANT -TO -WATER HEAT EXCHANGER FALLS BELOW 25 DEG F. g. CONDENSATE OVERFLOW SWITCH TO STOP COMPRESSOR WITH HIGH CONDENSATE LEVEL IN CONDENSATE DRAIN PAN. 6. REFRIGERANT PIPING MATERIALS: ASTM B 743 COPPER TUBE WITH WROUGHT -COPPER FITTINGS AND BRAZED JOINTS. 7. PIPE INSULATION: REFRIGERANT MINIMUM 3/8 -INCH -THICK, FLEXIBLE ELASTOMERIC INSULATION ON PIPING EXPOSED TO AIRFLOW THROUGH THE UNIT. MAXIMUM 25/50 FLAME-SPREAD/SMOKE- DEVELOPMENT INDEXES ACCORDING TO ASTM E 84. 8. REFRIGERANT METERING DEVICE: THERMAL EXPANSION VALVE TO ALLOW SPECIFIED OPERATION WITH ENTERING -WATER TEMPERATURES FROM 25° F TO 120' F. G. ELECTRIC HEATING COIL: HELIX -WOUND, NICKEL -CHROMIUM WIRE -HEATING ELEMENTS IN CERAMIC INSULATORS MOUNTED ON STEEL SUPPORTS. ENERGIZE ON CALL FOR HEATING WHEN ENTERING -WATER -LOOP TEMPERATURE IS LESS THAN 25 DEG F. H. FILTERS: DISPOSABLE, PLEATED TYPE, 1" INCH THICK MERV 11. I. CONTROLS 1. BASIC UNIT CONTROLS: DDC a. LOW AND HIGH-VOLTAGE PROTECTION. b. OVER CURRENT PROTECTION FOR COMPRESSOR AND FAN MOTOR. C. RANDOM TIME DELAY, THREE TO TEN SECONDS, START ON POWER UP. d. TIME DELAY OVERRIDE FOR SERVICING. e. CONTROL VOLTAGE TRANSFORMER. 2. THERMOSTAT: a. UNIT -MOUNTED TEMPERATURE SENSOR. b. LED TO INDICATE FAULT CONDITION AT HEAT PUMP. C. DATA ENTRY AND ACCESS PORT. 1) INPUT DATA INCLUDE ROOM TEMPERATURE AND HUMIDITY SET POINTS FOR OCCUPIED AND UNOCCUPIED PERIODS. 2) OUTPUT DATA INCLUDE ROOM TEMPERATURE AND HUMIDITY, SUPPLY -AIR TEMPERATURE, ENTERING -WATER TEMPERATURE, OPERATING MODE, AND STATUS. 3. TERMINAL CONTROLLER: a. REMOTE CONTROL PANEL TO CONTAIN PROGRAMMABLE TIMER AND LED FOR FAULT CONDITION. b. COMPRESSOR DISABLE RELAY TO STOP COMPRESSOR OPERATION FOR DEMAND LIMITING OR SWITCH TO UNOCCUPIED OPERATION. C. AUTOMATIC RESTART AFTER FIVE MINUTES IF FAULT CLEARS. LOCKOUT AFTER THREE ATTEMPTS TO RESTART FOLLOWING FAULT. INDICATE FAULT FOR SERVICE TECHNICIAN. d. RETURN -AIR TEMPERATURE HIGH -LIMIT (FIRESTAT). STOP UNIT ON HIGH TEMPERATURE. e. BACKUP FOR VOLATILE MEMORY. J. ELECTRICAL CONNECTION: SINGLE ELECTRICAL CONNECTION WITH FUSED DISCONNECT. 23. HOSE KITS A. GENERAL: HOSE KITS SHALL BE STAINLESS STEEL AND DESIGNED FOR MINIMUM 400 PSIG WORKING PRESSURE, AND OPERATING TEMPERATURES FROM 25 TO 211 DEG. F. TAG HOSE KITS TO EQUIPMENT DESIGNATIONS. B. HOSE: LENGTH 24 INCHES. MINIMUM DIAMETER, EQUAL TO WATER -SOURCE HEAT -PUMP CONNECTION SIZE. C. ISOLATION VALVES: TWO-PIECE BRONZE -BODY BALL VALVES WITH STAINLESS-STEEL BALL AND STEM AND GALVANIZED -STEEL LEVER HANDLE. PROVIDE VALVE FOR SUPPLY AND RETURN. IF BALANCING DEVICE IS COMBINATION SHUTOFF TYPE WITH MEMORY STOP, THE ISOLATION VALVE MAY BE OMITTED ON THE RETURN. D. STRAINER: Y -TYPE WITH BLOW DOWN VALVE IN SUPPLY CONNECTION. E. BALANCING DEVICE: MOUNT IN RETURN CONNECTION. INCLUDE METER PORTS TO ALLOW FLOW MEASUREMENT WITH DIFFERENTIAL PRESSURE GAGE. F. MANUAL, CALIBRATED -ORIFICE BALANCING VALVE. 24. EXHAUST FANS A. CEILING MOUNTED DIRECT DRIVE CENTRIFUGAL EXHAUST VENTILATOR. FANS SHALL BE UL LISTED AND BEAR THE AMCA CERTIFIED RATING SEAL FOR SOUND AND AIR PERFORMANCE. B. ALL FASTENERS SHALL BE CORROSION RESISTANT. ALUMINUM BASE SHALL HAVE CONTINUOUSLY WELDED CURB CAP CORNERS. MOTOR, BEARINGS AND DRIVE SHALL BE MOUNTED ON A STEEL ASSEMBLY, ISOLATED FROM THE FAN STRUCTURE WITH RUBBER VIBRATION ISOLATORS. C. WHEEL SHALL BE CENTRIFUGAL BACKWARD INCLINED TYPE, CONSTRUCTED OF ALUMINUM, WITH A MACHINED CAST ALUMINUM HUB. D. MOTOR SHALL BE HEAVY DUTY TYPE WITH PERMANENTLY LUBRICATED SEALED BALL BEARINGS. E. FAN BEARINGS SHALL BE HEAVY DUTY REGREASABLE BALL TYPE WITH A CAST IRON HOUSING, RATED IN EXCESS OF 200,000 HOURS AT MAXIMUM CATALOGED OPERATING SPEED. F. BELTS SHALL BE OIL AND HEAT RESISTANT, NON -STATIC TYPE. DRIVES SHALL BE MACHINED CAST IRON, KEYED AND SECURELY ATTACHED TO WHEEL AND MOTOR SHAFTS AND SIZED FOR 150 PERCENT OF THE INSTALLED MOTOR HORSEPOWER G. ACCEPTABLE MANUFACTURERS: BROAN, PENN VENTILATOR, COOK GREENHECK AND ACME. 25. TEMPERATURE CONTROLS A. ALL TEMPERATURE CONTROL COMPONENTS, WIRING AND CONDUIT SHALL BE THE RESPONSIBILITY OF THE HVAC CONTRACTOR. B. WIRING AND CONDUIT (1) ALL 24 VOLT WIRING SHALL BE INSTALLED IN CONDUIT, IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE. (2) ALL OUTDOOR 24 VOLT WIRING SHALL BE INSTALLED IN CONDUIT, IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE. B. HVAC CONTRACTOR SHALL USE BUILDING APPROVED TEMPERATURE CONTROL CONTRACTOR AND MANUFACTURER. C. TEMPERATURE CONTROL CONTRACTOR SHALL INCLUDE COST OF INTEGRATING NEW UNITS INTO BUILDING BAS. INTEGRATION SHALL INCLUDE BUT IS NOT LIMITED TO; UPDATING GRAPHICS, POPULATING CONTROL POINT LISTS, ETC. 26. TEMPORARY SERVICES A. HVAC CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AND PROVIDE TEMPORARY SPACE CONDITIONING (HEATING AND COOLING AS REQUIRED) IN ORDER TO MAINTAIN TEMPERATURES AND HUMIDITY LEVELS AS REQUIRED FOR GENERAL CONSTRUCTION. B. UTILITY CONNECTIONS REQUIRED FOR TEMPORARY HEATING/COOLING SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR. COORDINATE WITH GENERAL CONTRACTOR FOR UTILITY (GAS/ELECTRIC) USE REQUIREMENTS. IT SHALL NOT BE THE RESPONSIBILITY OF THIS CONTRACTOR TO PAY FOR THE UTILITIES USED DURING PROJECT CONSTRUCTION. C. EXISTING OR NEW HVAC SYSTEMS USED DURING CONSTRUCTION: (1) NEW OR EXISTING SYSTEMS SHALL NOT BE USED WITHOUT THE KNOWLEDGE AND CONSENT OF THE OWNER, ARCHITECT AND ENGINEER. (2) CONTRACTOR SHALL ADHERE TO BUILDING GUIDELINES FOR OPERATING NEW/EXISTING HVAC SYSTEMS DURING CONSTRUCTION. (3) ALL SYSTEM RETURN AIR GRILLES SHALL BE PROTECTED USING FILTRATION MEDIA WITH A MINIMUM EFFICIENCY RATING VALUE (MERV) OF 8, PER ASHRAE 52.2. (4) ALL HVAC SYSTEMS AND AIR DISTRIBUTION DEVICES USED DURING CONSTRUCTION SHALL BE CLEANED PER CURRENT NATIONAL AIR DUCT CLEANING ASSOCIATION GENERAL SPECIFICATIONS. 27. PROJECT COMPLETION: C. UPON COMPLETION OF PROJECT THIS CONTRACTOR SHALL PROVIDE NEW FILTERS WITHIN ALL EXISTING AND FAN POWERED EQUIPMENT. D. ALL EXISTING AND NEW FAN POWERED EQUIPMENT SHALL HAVE THEIR EXTERIOR CLEANED WITH A MILD SOAP AND WATER SOLUTION AND THOROUGHLY DRIED. E. PROVIDE 3 COPIES OF FINAL TEST AND BALANCE REPORT TO OWNER/ARCHITECT. • Integrated 1;� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc HELLYER Drawn by: M E B Checked by: AJM Approved by: AJM LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Mechanical Specifications No. M-5.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: 1/8" = 11-0" Drawing: Mechanical Specifications No. M-5.04 PLUMBING SPECIFICATIONS 1. GENERAL PROVISIONS A. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, ALTERNATES, ADDENDA'S', AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. CONTRACTORS AND SUBCONTRACTORS SHALL EXAMINE SAME AS WELL AS OTHER DIVISIONS OF THE SPECIFICATIONS WHICH AFFECT WORK UNDER THIS DIVISION. B. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, SUPPLIES, SERVICES, AND SHALL PERFORM ALL WORK COMPLETE AND IN STRICT ACCORDANCE WITH THIS SPECIFICATION AND APPLICABLE DRAWINGS. ANY DEVIATIONS SHALL BE CLEARLY DEFINED AND ITEMIZED IN ACCORDANCE WITH SECTION 10.F OF THIS SPECIFICATION. C. THIS CONTRACTOR IS INSTRUCTED TO READ CAREFULLY THE SPECIFICATIONS FOR ALL PARTS OF THE WORK, WHICH INCLUDE THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION, CIVIL, STRUCTURAL AND ALL OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS THAT ARE PART OF THE CONTRACT DOCUMENTS. D. ALL ITEMS OF LABOR, MATERIAL AND EQUIPMENT NOT SPECIFICALLY MENTIONED HEREIN OR SHOWN ON PLANS, BUT INCIDENTAL TO, OR REQUIRED FOR THE COMPLETE INSTALLATION AND PROPER OPERATION OF THE WORK, SHALL BE FURNISHED AS IF CALLED FOR IN DETAIL BY THE SPECIFICATIONS OR DRAWINGS. E. AS USED IN THIS SPECIFICATION, "PROVIDE" MEANS "FURNISH AND INSTALL". "FURNISH" MEANS "TO PURCHASE AND DELIVER TO THE PROJECT SITE COMPLETE WITH EVERY NECESSARY APPURTENANCE AND SUPPORT," AND "INSTALL" MEANS "TO UNLOAD AT THE DELIVERY POINT AT THE SITE AND PERFORM EVERY OPERATION NECESSARY FOR PROPER INSTALLATION PER CODES AND MANUFACTURERS REQUIREMENTS, TO ESTABLISH SECURE MOUNTING AND CORRECT OPERATION AT THE PROPER LOCATION IN THE PROJECT. 2. PERMITS, CODES, INSPECTIONS, AND TESTS A. THE PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED FOR THE PROSECUTION OF PLUMBING WORK. ALL PERMITS AND CERTIFICATES OF INSPECTION AND APPROVAL SIGNED BY THE CONTROLLING BUILDING DEPARTMENT SHALL BECOME PROPERTY OF THE OWNER. B. DRAWINGS INDICATE THE MINIMUM DESIGN REQUIREMENTS. NATIONAL, STATE, AND LOCAL CODES SHALL BE FOLLOWED. COMPLY WITH THE LATEST EDITIONS OF THE LOCAL GOVERNING PLUMBING CODE, LOCAL GOVERNING MECHANICAL CODE, AND NFPA STANDARDS. THE CONTRACTOR SHALL INCLUDE THE COST OF SATISFYING SUCH CODES AND STANDARDS IN HIS BID.FOLLOWING COMPLETION OF THE PLUMBING WORK, FURNISH TO THE OWNER, IN DUPLICATE, CERTIFICATES OF INSPECTION AND APPROVAL BY REGULATORY AGENCIES HAVING JURISDICTION. (1) DEMONSTRATE TO THE OWNER'S SATISFACTION THE PROPER OPERATION OF EACH OF THE SYSTEMS COMPRISING THIS CONTRACT BEFORE FINAL PAYMENT. (2) IMMEDIATELY CORRECT ANY WORK FOUND AT VARIANCE WITH THESE SPECIFICATIONS, THE NATIONAL, STATE, AND LOCAL CODES, AND REQUIREMENTS OF GOVERNING REGULATORY AGENCIES. (3) TEST PIPING FOR LEAKS; REPAIR LEAKS IN COPPER TUBING BY SWEATING OUT JOINTS, THOROUGHLY CLEANING BOTH TUBE AND FITTING, AND RE -SOLDERING OR RE -BRAZING; CORRECT LEAKS IN SCREWED JOINTS BY REPLACING THREAD OR FITTING OR BOTH. a. DOMESTIC WATER SHALL BE TESTED WITH WATER AT A PRESSURE OF 125 PSI FOR 6 HOURS. b. NATURAL GAS SHALL BE TESTED WITH COMPRESSED AIR AT A PRESSURE OF 1-1/2 TIMES THE PROPOSED MAXIMUM WORKING PRESSURE (BUT NOT LESS THAN 3 PSI) FOR 24 HOURS. TESTING PROCEDURE SHALL CONFORM TO NFPA 54 "NATIONAL FUEL GAS CODE" AND ICC FUEL GAS CODE REQUIREMENTS. c. SANITARY DRAIN AND VENT AND STORM PIPING SHALL BE TESTED WITH WATER PER GOVERNING PLUMBING CODE AND THE LOCAL AUTHORITY. 3. VISIT TO THE SITE A. THE CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH ALL CONDITIONS AFFECTING THE WORK. THE SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE KNOWLEDGE OF ALL SUCH CONDITIONS AND NO ADDITIONAL COMPENSATION SHALL BE ALLOWED WHERE EXTRA LABOR OR MATERIALS ARE REQUIRED BECAUSE OF IGNORANCE OF THESE CONDITIONS. 4. PROTECTION A. THE PLUMBING CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION FROM DIRT AND WATER DURING CONSTRUCTION NECESSITATED BY PLUMBING WORK. PROTECTION METHODS ARE SUBJECT TO APPROVAL BY THE ARCHITECT. 5. EQUIPMENT AND MATERIALS A. ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND SHALL CONFORM TO UNDERWRITERS' LABORATORIES STANDARDS, WHERE APPLICABLE. WHERE SPECIFICATIONS DESCRIBE, OR PLANS SHOW, MATERIALS OR EQUIPMENT OF HIGHER QUALITY THAN REQUIRED BY CODE AND LOCAL RULING, THE DRAWINGS AND SPECIFICATIONS SHALL GOVERN THE QUALITY OF THE MATERIAL OR EQUIPMENT. B. THE CONTRACTOR SHALL SUBMIT PROOF, IF REQUESTED BY THE OWNER THAT THE MATERIALS, APPLIANCES, EQUIPMENT OR DEVICES FURNISHED AND INSTALLED UNDER THIS CONTRACT, MEET THE REQUIREMENTS OF THE UNDERWRITERS' LABORATORIES, INC., AS REGARDS FIRE AND CASUALTY HAZARDS. THE LABEL OF OR LISTING BY THE UNDERWRITERS' LABORATORIES, INC. WILL BE ACCEPTED AS CONFORMING WITH THIS REQUIREMENT. IN LIEU OF THE LABEL OR LISTING, THE CONTRACTOR MAY SUBMIT INDEPENDENT PROOF SATISFACTORY TO THE ARCHITECT THAT THE MATERIALS, APPLIANCES OR DEVICES CONFORM TO THE PUBLISHED STANDARDS, INCLUDING METHODS OF TEST OF THE UNDERWRITERS' LABORATORIES, INC. UNDERWRITERS' LABORATORIES, INC. AND ITS PUBLICATIONS WILL BE REFERRED TO HEREINAFTER BY THE ABBREVIATION UL, WITH OR WITHOUT ADDITIONAL IDENTIFYING SYMBOLS. 6. GUARANTEE A. THE PLUMBING CONTRACTOR SHALL GUARANTEE FOR A PERIOD OF ONE YEAR THAT ALL WORK AND EQUIPMENT WILL REMAIN FREE FROM ALL DEFECTS IN WORKMANSHIP AND MATERIALS, AND THAT IT WILL COMPLY WITH ALL THE SPECIFIC REQUIREMENTS OF THE SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS GOVERNING THE WORK. B. ALL WORK FOUND BY THE ENGINEER TO BE DEFECTIVE WILL BE REPLACED WITH NEW WORK MEETING ALL THE REQUIREMENTS OF THE CONTRACT. THE PLUMBING CONTRACTOR WILL BEAR ALL COSTS OF SUPPLYING SUCH NEW WORK, AND INSTALLING AND FINISHING SAME, AND WILL ASSUME ALL COSTS FOR REPLACING OTHER WORK DAMAGED BY THE REMOVAL AND REPLACEMENT OF ANY OF THE WORK. THE PLUMBING CONTRACTOR WILL BEAR ALL COSTS FOR FREIGHT, DRAYAGE AND DEMURRAGE, AND ALL LABOR IN CONNECTION THEREWITH. 7. CUTTING, PATCHING, FIRESTOPPING AND PAINTING A. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING ALL HOLES REQUIRED FOR INSTALLATION OF PLUMBING WORK. HOLES SHALL BE CUT IN A NEAT MANNER SATISFACTORY TO THE ARCHITECT. B. CONTRACTOR SHALL EMPLOY AN BUILDING OWNER APPROVED ROOFING CONTRACTOR FOR ALL ROOF PENETRATIONS. ROOF SHALL BE REPAIRED SO AS NOT TO VOID ROOF WARRANTY. C. UNLESS NOTED OTHERWISE, ALL HOLES OR DAMAGE CAUSED BY THE REMOVAL OF EXISTING WORK OR THE INSTALLATION OF NEW WORK SHALL BE PROPERLY PATCHED BY THIS CONTRACTOR. HOLES SHALL BE NEATLY PATCHED AND PAINTED WITH SUITABLE MATERIAL TO MATCH EXISTING SURFACES. HOLES THROUGH FLOORS OR FIRE WALLS SHALL BE SEALED WITH THE APPROPRIATE INTUMESCENT CAULK, PUTTY, STRIP OR SHEET TYPE FIRE BARRIER PRODUCT. D. FIRESTOP SYSTEM (REQUIRED FIRESTOPPING MATERIALS) SHALL BE DETERMINED BY THE WALL OR FLOOR/CEILING ASSEMBLY AND PENETRATION TYPE AND SHALL BE UL LISTED AND TESTED IN ACCORDANCE WITH ASTM E814. FIRE RATING OF THE FIRESTOP SYSTEM SHALL BE EQUIVALENT TO THE ASSEMBLY WHICH IS PENETRATED. E. ACCEPTABLE FIRE BARRIER PRODUCTS: HILTI "FS -ONE", NELSON "FLAMESEAL" OR APPROVED EQUAL AS MANUFACTURED BY 3M. 8. EXCAVATING, TRENCHING, AND BACKFILLING: A. FURNISH MATERIALS, TOOLS, LABOR AND SUPERVISION NECESSARY TO PROVIDE ALL EXCAVATING, TRENCHING AND BACKFILLING REQUIRED FOR THE PROPER INSTALLATION OF EQUIPMENT AND PIPING. B. EXACT ROUTING OF TRENCHING SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED, IN ADVANCE, BY THE OWNER. C. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE GOVERNING AUTHORITIES. D. WHERE TRENCHES ARE EXCAVATED SUCH THAT THE BOTTOM OF THE TRENCH FORMS THE BED FOR THE PIPE, SOLID AND CONTINUOUS LOAD-BEARING SUPPORT SHALL BE PROVIDED BETWEEN JOINTS. BELL HOLES, HUB HOLES AND COUPLED HOLES SHALL BE PROVIDED AT POINTS WHERE THE PIPE IS JOINED. SUCH PIPE SHALL NOT BE SUPPORTED ON BLOCKS TO GRADE. 9. CLEANING AND PAINTING A. CLEAN NEW PIPING AFTER WORK IS COMPLETE TO REMOVE PIPE DOPE, LOOSE MILL SCALE AND OTHER EXTRANEOUS MATERIALS. B. TOUCH UP AND REPAIR ANY DAMAGED FACTORY FINISHES ON EQUIPMENT AND MATERIALS FURNISHED. OTHER PAINTING WILL BE DONE UNDER THE PAINTING DIVISION OF THE SPECIFICATIONS. 10. COORDINATION AND CONDUCT OF WORK A. PLUMBING CONTRACTOR SHALL COORDINATE ALL NEW (GAS, DOMESTIC WATER, SANITARY) UTILITY CONNECTIONS AND METERING REQUIREMENTS WITH LOCAL UTILITY COMPANY. B. PLUMBING DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT, APPROXIMATE SIZES, GENERAL LOCATIONS OF EQUIPMENT, AND PIPING. VERIFY DIMENSIONS IN FIELD; ADJUST TO MANUFACTURER'S SHOP DRAWINGS. DO NOT SCALE DRAWINGS. C. ALL REQUESTS FOR INFORMATION SUPPLEMENTAL TO THE CONSTRUCTION DOCUMENTS SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT FOR DISTRIBUTION TO THE APPROPRIATE PARTY(S). D. DRAWINGS AND SPECIFICATIONS ARE TO BE CONSIDERED AS SUPPLEMENTING EACH OTHER. WORK SPECIFIED BUT NOT SHOWN, OR SHOWN BUT NOT SPECIFIED, SHALL BE PERFORMED OR FURNISHED AS THOUGH MENTIONED IN BOTH SPECIFICATIONS AND DRAWINGS. E. ARCHITECTURAL AND STRUCTURAL DRAWINGS SUPERSEDE PLUMBING DRAWINGS. DETERMINE THAT WORK OF THIS DIVISION CAN BE ACCOMMODATED WITHIN SPACES PROVIDED. NOTIFY ARCHITECT OF ANY INTERFERENCES BEFORE STARTING INSTALLATION. F. DETERMINE SIZES, LOCATIONS FOR CHASES AND OPENINGS NECESSARY FOR INSTALLATION OF PLUMBING WORK. COOPERATE WITH OTHER TRADES IN SETTING SLEEVES, INSERTS AND HANGERS. G. COORDINATE THIS WORK WITH ALL TRADES. ARRANGE OPERATIONS SO AS NOT TO DELAY INSTALLATION OR COMPLETION OF ANY PARTS OF INTERRELATED WORK SO THAT CONSTRUCTION MAY PROCEED ON SCHEDULE. H. COOPERATE WITH ALL TRADES IN PREPARING INTERFERENCE DRAWINGS FOR AREAS WHERE THERE IS POSSIBLE CONFLICT BETWEEN TRADES. EXACT LOCATION OF PIPES, AND EQUIPMENT SHALL BE BASED ON FIELD MEASUREMENTS WITH FINAL ARRANGEMENT DETERMINED BY INTRA -TRADE AGREEMENTS SUBJECT TO ARCHITECT'S APPROVAL. I. ARCHITECT RESERVES THE RIGHT TO MAKE REASONABLE CHANGES IN INDICATED LOCATIONS WITHOUT EXTRA COST TO THE OWNER. J. ALL WORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER BY FIRST-CLASS MECHANICS. THE CONTRACTOR SHALL PROVIDE ADEQUATE AND COMPETENT SUPERVISION OF THE JOB AS REQUIRED. K. PIPING AND EQUIPMENT SHALL BE ARRANGED SUBSTANTIALLY AS INDICATED. ANY CHANGE RESULTING IN A SAVINGS IN LABOR OR MATERIAL SHALL BE MADE ONLY IN ACCORDANCE WITH A CONTRACT CHANGE ORDER. DEVIATIONS SHALL BE MADE ONLY WHERE NECESSARY TO AVOID INTERFERENCES AND ONLY AFTER DRAWINGS SHOWING THE PROPOSED DEVIATIONS HAVE BEEN SUBMITTED TO AND APPROVED BY THE ARCHITECT. L. COORDINATE ALL SHUTDOWNS OF THE PLUMBING SYSTEM IN ADVANCE WITH THE OWNER. 11. SUBMITTALS A. PROVIDE A MINIMUM OF SIX (6) SUBMITTAL DRAWINGS FOR PLUMBING FIXTURES, EQUIPMENT, AND ALL OTHER SPECIFIED COMPONENTS FOR APPROVAL BY THE ARCHITECT AND ENGINEER. B. WHERE ONLY ONE MAKE OF EQUIPMENT IS NAMED, IT SHALL BE PROVIDED AS SPECIFIED. C. VERBAL REQUESTS OF APPROVALS FOR ANY SUBSTITUTION WILL NOT BE BINDING ON THE ARCHITECT AND OWNER. ��;�,���� RELEASES IFR CmW3TRlllCT10N 5uuh�j�oktio aumipdiian�c®wlNo ®III r�gwf�timns rn95tal� emd Ilmeal Or'"dle� IC'Itpo�F Cairrnrel "��� Dr�TEa 02/23/18 D. THIS CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR ALL COSTS FOR REDESIGN CHANGES NECESSARY BY ALL TRADES TO ACCOMMODATE THE USE OF EQUIPMENT NOT SPECIFIED ON PROJECT DOCUMENTS. E. BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVES. DRAWINGS AND SPECIFICATIONS ARE BASED ON THE PRODUCTS SPECIFIED BY TYPE, MODEL, AND SIZE AND THUS ESTABLISH MINIMUM QUALITIES, WHICH SUBSTITUTES MUST MEET TO QUALIFY FOR REVIEW. F. SHOULD THE CONTRACTOR PROPOSE TO FURNISH MATERIALS, EQUIPMENT, AND DEVICES, OTHER THAN THOSE SPECIFIED AND LISTED, THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR SUBSTITUTIONS, TO THE ENGINEER, AT LEAST FOURTEEN (14) CALENDAR DAYS PRIOR TO BID OPENING. THE REQUEST SHALL BE AN ALTERNATE TO THE ORIGINAL BID AND SHALL INCLUDE AND BE ACCOMPANIED WITH COMPLETE SPECIFICATIONS CUT SHEET SUBMITTAL AS OUTLINED IN SECTION 11.A OF THIS SPECIFICATION SECTION, COMPLETE WITH DESCRIPTIVE (MANUFACTURER, BRAND NAME, CATALOG NUMBER, ETC.) AND TECHNICAL DATA FOR ALL ITEMS. INDICATE ANY ADDITIONS OR DEDUCTIONS TO THE CONTRACT PRICE WITH THE SUBSTITUTION SUBMITTAL AND ON THE BID FORM. FAILURE TO PERFORM THESE ACTIONS EQUATES TO ACKNOWLEDGEMENT THAT THE PROJECT HAS BEEN BID WITH STRICT ACCORDANCE TO THIS SPECIFICATION AND APPLICABLE DRAWINGS. G. ACCEPTANCE OR REJECTION OF THE PROPOSED SUBSTITUTIONS SHALL BE SUBJECT TO APPROVAL OF THE ARCHITECT AND ENGINEER. IF REQUESTED, THE CONTRACTOR SHALL SUBMIT INSPECTION SAMPLES OF BOTH THE SPECIFIED AND THE PROPOSED SUBSTITUTE ITEMS. H. IF ANY SUBSTITUTIONS ARE APPROVED, AN ADDENDUM LISTING THE APPROVED ITEMS) WILL BE ISSUED TO ALL BIDDING CONTRACTORS PRIOR TO THE BID DATE. I. IN ALL CASES WHERE SUBSTITUTIONS ARE PERMITTED, THE CONTRACTOR SHALL BEAR ANY EXTRA COST OF EVALUATING THE EQUALITY OF THE MATERIAL AND EQUIPMENT TO BE INSTALLED. J. WHERE ONLY ONE MAKE IS NAMED IN THE SPECIFICATIONS OR ON THE DRAWINGS, IT SHALL BE PROVIDED. K. VERBAL REQUESTS OR APPROVALS SHALL NOT BE BINDING ON THE ENGINEER OR OWNER. 12. EQUIPMENT AND PIPING IDENTIFICATION A. LABEL ALL PIPING SYSTEMS WITH PIPE MARKERS INSTALLED ADJACENT TO VALVES, WHERE PIPES PASS THROUGH WALLS OR FLOORS, NEAR ALL BRANCHES AND CHANGES OF DIRECTION, AT 20 FEET INTERVALS ON STRAIGHT RUNS OF PIPE, AND AT ACCESS DOOR LOCATIONS. ALL PIPE MARKERS SHALL CONFORM TO ANSI A13.1 "SCHEME FOR THE IDENTIFICATION OF PIPING SYSTEMS". B. THE CONTRACTOR SHALL FURNISH AND INSTALL A SYSTEM OF NAMEPLATES DESIGNED TO IDENTIFY EACH PIECE OF EQUIPMENT. (1) NAMEPLATE LETTER AND NUMBERS SHALL MATCH EQUIPMENT DESIGNATION AS INDICATED ON THE DRAWINGS. (2) NAMEPLATES SHALL BE LAMINATED PHENOLIC WITH BLACK SURFACE AND WHITE CORE. USE 1/16" THICK MATERIAL FOR PLATES UP TO 2" BY 4". FOR LARGER SIZES USE 1/8" THICK. LETTERS AND NUMBERS SHALL BE A MINIMUM OF 1/2" HIGH. (3) FASTEN NAMEPLATES TO ALL EQUIPMENT BY THE USE OF STAINLESS STEEL SHEET METAL SCREWS. 13. AS -BUILT DRAWINGS A. AS WORK PROGRESSES, RECORD ON A SET OF "AS -BUILT" PRINTS ANY DEVIATIONS FROM DESIGN DRAWINGS. DELIVER TO THE OWNER BEFORE SUBMITTING REQUEST FOR FINAL PAYMENT. THE "AS -BUILT" PRINTS SHALL BE AN ACCURATE DEPICTION OF THE PROJECT AS COMPLETED. 14. OPERATING AND MAINTENANCE MANUALS A. PROVIDE TO OWNER, AT PROJECT TURNOVER, THREE (3) HARDBOUND COPIES OF OPERATING AND MAINTENANCE MANUALS FOR ALL EQUIPMENT AND SYSTEMS INSTALLED. MANUALS SHALL INCLUDE ALL RELEVANT INFORMATION NEEDED FOR DAY-TO-DAY OPERATION AND MANAGEMENT OF EACH SYSTEM, AS WELL AS EQUIPMENT MAINTENANCE INFORMATION REQUIRED TO SUPPORT THE MAINTENANCE PROGRAM. 15. OPERATING INSTRUCTIONS A. PROVIDE TO OWNER AFTER ALL EQUIPMENT IS IN OPERATION AND AT AN AGREEABLE TIME, INSTRUCTIONS FOR THE PURPOSE OF TRAINING OWNER'S PERSONNEL IN ALL PHASES OF OPERATION AND MAINTENANCE OF EQUIPMENT AND SYSTEMS. SCHEDULE TRAINING WITH OWNER, PROVIDE AT LEAST SEVEN DAYS PRIOR NOTICE. PROVIDE THIS TRAINING TO ALL PERSONNEL AND ON ALL SHIFTS. 16. INSULATION A. PROVIDE ALL INSULATION MATERIALS (INSULATION, JACKETS, FITTING COVERS, ADHESIVES, CEMENTS, MASTICS, SEALERS AND FINISHES) WITH A FLAME -SPREAD INDEX OF 25 OR LESS AND SMOKE DEVELOPED INDEX OF 50 OR LESS, AS TESTED UNDER PROCEDURE ASTM E-84 (NFPA 255). B. ALL INSULATION SHALL BE INSTALLED OVER CLEAN, DRY SURFACES. INSULATION MUST BE DRY AND IN GOOD CONDITION. WET OR DAMAGED INSULATION IS NOT ACCEPTABLE. NO INSULATION SHALL BE APPLIED PRIOR TO PRESSURE TEST COMPLETION OF THE RESPECTIVE PIPING SYSTEM. C. ALL INSULATION SHALL BE CONTINUOUS (INCLUDING VAPOR BARRIER) THROUGH WALL AND CEILING OPENINGS, SLEEVES, AND PIPE HANGER LOCATIONS. D. ALL INSULATION PRODUCTS SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS. THE WORKMANSHIP SHALL BE FIRST CLASS AND ALL JOINTS SHALL BE MADE TIGHT. E. INSULATE VALVE BONNETS AND UNIONS ON DOMESTIC WATER PIPING WITH INSULATION MATCHING PIPE INSULATION. F. INSULATE DOMESTIC COLD WATER PIPING AND FITTINGS WITH OWENS-CORNING ONE-PIECE FIBERGLASS PIPE INSULATION WITH ALL SERVICE JACKET, 1/2" THICKNESS FOR PIPING LESS THAN OR EQUAL TO 1.5", 1" THICKNESS FOR PIPES LARGER THAN 1.5". INSULATE DOMESTIC HOT WATER PIPING AND FITTINGS WITH THE SAME INSULATION, 1" THICKNESS FOR PIPING LESS THAN OR EQUAL TO 1.5", 2" THICKNESS FOR PIPING LARGER THAN 1.5". G.INSULATE HORIZONTAL STORM PIPING AND ROOF DRAIN SUMPS WITH OWENS-CORNING ONE PIECE FIBERGLASS PIPE INSULATION WITH ALL SERVICE JACKET, 1/2" THICKNESS. H.INSULATE ELECTRIC WATER COOLER TRAP AND WASTE PIPING WITHIN CABINET WITH 1/2" THICK ARMAFLEX AP PIPING INSULATION. I. REPAIR EXISTING INSULATION WHERE REMOVED FOR NEW CONNECTION. INSULATION SHALL BE THE SAME AS SPECIFIED FOR NEW SERVICE. K. ALL INSULATION USED AS PLENUM WRAP COVERING FOR COMBUSTIBLE MATERIALS IN A PLENUM SPACE SHALL BE 3M PLENUM PROTECTION SYSTEM (PP -100-P), ONE LAYER OF 3M FIRE BARRIER DUCT WRAP 5A, IN ACCORDANCE WITH UL910 & UL1887. 17. MATERIALS A. PIPE AND FITTINGS (1) DOMESTIC WATER SHALL BE TYPE "L" COPPER. (2) SANITARY DRAIN AND VENT PIPING LOCATED IN RETURN AIR PLENUM SHALL BE SERVICE WEIGHT NO HUB CAST IRON PIPE. ALL CAST IRON PIPE AND FITTINGS SHALL COMPLY WITH ASTM A 888 (OR A 74) AND BE MARKED WITH THE COLLECTIVE TRADEMARK OF THE CAST IRON SOIL PIPE INSTITUTE (CISPI) AND BE LISTED BY THE NSF INTERNATIONAL. (3) FITTINGS FOR COPPER PIPE SHALL BE WROUGHT COPPER SOLDER JOINT TYPE. ONLY LEAD FREE SOLDER IS ACCEPTABLE. (4) FITTINGS FOR BLACK STEEL PIPE 2" AND SMALLER SHALL BE 150 PSIG SWP MALLEABLE IRON SCREWED FITTINGS. FOR 2-1/2" AND LARGER, FITTINGS SHALL BE FACTORY FORMED WELDING FITTINGS. (5) FITTINGS FOR SANITARY DRAIN AND VENT PIPING LOCATED IN RETURN AIR PLENUM SHALL BE SERVICE WEIGHT NO HUB CAST IRON PIPE WITH STAINLESS STEEL MECHANICAL JOINT COUPLINGS. COUPLINGS SHALL COMPLY WITH "CISPI 310". THE ELASTOMERIC SEALING SLEEVE SHALL CONFORM TO "ASTM C 564" AND SHALL BE PROVIDED WITH A CENTER STOP. MECHANICAL JOINT COUPLINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. B. DOMESTIC WATER VALVES (1) DOMESTIC WATER SHUT-OFF VALVES SHALL BE BRONZE BODY, TWO PIECE, FULL PORT, LEVER HANDLE BALL VALVES WITH TEFLON SEATS, CHROME PLATED BRASS BALL, BRASS STEM AND SOLDER ENDS. 600 PSI WOG. ACCEPTABLE MANUFACTURERS: MILWAUKEE, HAMMOND, APOLLO (2) HORIZONTAL CHECK VALVES SHALL BE BRONZE BODY, SWING TYPE DESIGN, BRONZE DISC, STAINLESS STEEL LEVER WITH SOLDER ENDS. 200 PSI WOG. ACCEPTABLE MANUFACTURERS: MILWAUKEE, HAMMOND, APOLLO (3) MANUAL BALANCING VALVES SHALL BE BRONZE BODY, COMBINATION VENTURI AND BALL VALVE WITH TWO PRESSURE/TEMPERATURE TEST PORTS, MEMORY STOP, INLET UNION CONNECTION AND THREADED ENDS, 400 PSI AT 2507. ACCEPTABLE MANUFACTURERS: FLOW DESIGN INC. "FLOWSET". 18. PIPING INSTALLATION A. PROVIDE MACHINE CUT STEEL PIPE SLEEVE 1" LARGER THAN OUTSIDE DIAMETER OF PIPE. WHERE FLOORS ARE CORE DRILLED, STEEL SLEEVES ARE NOT REQUIRED. SEAL OPENINGS TO MAINTAIN THE INTEGRITY OF THE FIRE RATING. B. PROVIDE ALL INSERTS, FASTENERS AND SUPPORTS TO PROPERLY SUPPORT AND RETAIN PIPING; TO CONTROL EXPANSION, CONTRACTION, ANCHORAGE, DRAINAGE, AND PREVENT SWAY AND VIBRATION. PIPING SHALL BE SO SUPPORTED AS NOT TO PLACE A STRAIN ON VALVES, FIXTURES OR EQUIPMENT. C. THE DRAWINGS INDICATE THE GENERAL LOCATION AND ARRANGEMENT OF THE PIPING SYSTEMS. SO FAR AS PRACTICAL, INSTALL PIPING AS INDICATED MAKING CONNECTIONS TO ALL EQUIPMENT AND FIXTURES. INSTALL PIPING AS DIRECT AS POSSIBLE AVOIDING UNNECESSARY OFFSETS. HOWEVER, IF OFFSETS ARE REQUIRED IN ORDER TO OBTAIN MAXIMUM HEADROOM OR TO AVOID CONFLICT WITH OTHER WORK, THEY SHALL BE MADE AS REQUIRED OR AS REQUESTED BY THE ARCHITECT WITHOUT ADDITIONAL COST TO THE OWNER. THE ARCHITECT RESERVES THE RIGHT TO MAKE MINOR CHANGES IN THE LOCATION OF PIPING AND EQUIPMENT DURING THE ROUGHING -IN, WITHOUT ADDITIONAL COST TO THE OWNER. ALL CHANGES PROPOSED BY OTHERS SHALL BE APPROVED BY THE ARCHITECT. D.INSTALL PIPING FREE OF SAGS OR BENDS E. ALL PIPING SYSTEMS MUST BE INSTALLED SO THEY CAN BE COMPLETELY DRAINED. PROVIDE TEE FITTING, BALL VALVE WITH HOSE THREAD FITTING AND CAP AT ALL LOW POINTS, TRAPPED SECTIONS, BASES OF RISERS, AND ON EQUIPMENT SIDE OF SHUT OFF VALVES TO PERMIT DRAINING. PROVIDE BALL VALVES AT ALL HIGH POINTS TO ALLOW VENTING. ALL DRAIN VALVES AND VENTS SHALL BE ACCESSIBLE F. TERMINATE PLUMBING VENT PIPES AT LEAST 12 INCHES ABOVE ROOF. G. BUILDING DRAINS SHALL BE PITCHED A MINIMUM SLOPE OF 1/4 INCH PER FOOT FOR PIPES UP TO 2-1/2 INCH AND 1/8 INCH PER FOOT FOR PIPES GREATER THAN 2-1/2 INCHES. H. PROVIDE WATER HAMMER ARRESTERS WHERE QUICK -CLOSING VALVES ARE UTILIZED, AND INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. J. PROVIDE CHECK VALVES WHERE BACKFLOW PROTECTION IS REQUIRED, AND INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. PROVIDE AT FIXTURES SUCH AS, BUT NOT LIMITED TO; DISHWASHERS, COFFEE MAKERS, ICE MACHINES, BEVERAGE DISPENSERS, REFRIGERATORS. PROVIDE WATTS 007 OR EQUIVALENT. K. PROVIDE DIELECTRIC UNIONS AT COUPLING OF DISSIMILAR METALS 19. DISINFECTION A. CHLORINATE ALL DOMESTIC WATER SYSTEMS AS FOLLOWS. FIRST FLUSH SYSTEM WITH CLEAN POTABLE WATER UNTIL DIRTY WATER DOES NOT APPEAR AT OUTLETS. THEN FILL WITH A WATER/CHLORINE SOLUTION (50PPM CHLORINE) AND ALLOW TO STAND FOR 24 HOURS. FOLLOWING STANDING TIME, FLUSH THE SYSTEM WITH CLEAN POTABLE WATER UNTIL CHLORINE IS PURGED FROM THE SYSTEM. REPEAT CHLORINATION, IF NECESSARY, UNTIL NO BACTERIOLOGICAL CONTAMINATION IS PRESENT IN THE SYSTEM. PROCEDURE SHALL CONFORM TO AWWA C651 AND BE ACCEPTED BY THE LOCAL HEALTH DEPARTMENT. 20. PLUMBING FIXTURES AND EQUIPMENT A. GENERAL (1) PROVIDE FIXTURES OF TYPE, STYLE AND MATERIAL AS SCHEDULED ON THE DRAWINGS. INCLUDE ALL TRIM, CARRIERS, SEATS, ETC. AS INDICATED OR RECOMMENDED BY MANUFACTURER AS REQUIRED FOR A COMPLETE INSTALLATION. (2) PROVIDE VACUUM BREAKERS AS PART OF THE FIXTURE OR EQUIPMENT TRIM WHEREVER THERE IS A POSSIBILITY OF BACK SIPHONING. (3) PROVIDE DOUBLE CHECK VALVES FOR PLUMBING FIXTURE OR SPECIAL EQUIPMENT WHERE BACKFLOW PROTECTION IS REQUIRED, AND INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS, USE WATTS SERIES 7 BRONZE DUAL CHECK VALVE. (4) PROVIDE FIXTURES CONSTRUCTED OF VITREOUS CHINA WITH ALL VISIBLE SURFACES GLAZED. FURNISH ENAMELED CAST IRON FIXTURES CONSTRUCTED WITH NON -STAINING, ACID RESISTANT, PORCELAIN ENAMELED COAT THOROUGHLY FUSED ON THE SURFACES. FURNISH STAINLESS STEEL SINKS WITH SATIN FINISH, UNLESS NOTED OTHERWISE. 5 PROVIDE ALL STOPS SUPPLIES TRAPS AND ESCUTCHEONS NECESSARY FOR A COMPLETE INSTALLATION. ALL COMPONENTS SHALL BE CHROME PLATED BRASS. (6) STOPS SHALL BE STRAIGHT OR ANGLE TYPE AS REQUIRED BY THE INSTALLATION, WITH LOOSE KEY, METAL STEM AND HER CUP WITH SET SCREW WASHER RETAINER. (7) SUPPLIES SHALL BE FLEXIBLE CHROME PLATED COPPER. (8) TRAPS SHALL BE 17 GAUGE CHROME PLATED BRASS WITH CLEAN-OUT PLUG. FURNISH WITH SLIP NUTS, WALL BEND AND ESCUTCHEON. (9) PROVIDE CARRIERS AND SUPPORTS AS REQUIRED FOR PROPER FIXTURE INSTALLATION. TYPE SHALL PERMIT FIELD ADJUSTMENT TO FIT VARIATIONS IN CONSTRUCTION. UNLESS NOTED OTHERWISE, SUPPORT ALL WALL MOUNTED PLUMBING FIXTURES ON CONCEALED CHAIR CARRIERS WITH FOOT SUPPORT. (10)PROVIDE FAUCET AERATORS AND OUTLETS OF TYPES APPROVED BY THE LOCAL HEALTH DEPARTMENT AND LOCAL PLUMBING CODE, REFER TO IPC TABLE 604.4. (11)INSULATE ALL EXPOSED WATER SUPPLIES AND TRAPS WHERE FIXTURES ARE INDICATED TO COMPLY WITH THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT. INSULATION KITS SHALL BE 3/16" THICK MOLDED CLOSED CELL VINYL CONSTRUCTION WITH PVC SATIN WHITE COVER. PLUMBING ABBREVIATIONS AFF ABOVE FINISHED FLOOR GR GRADE AP ACCESS PANEL GCO GRADE CLEANOUT AV ACID VENT ID INSIDE DIAMETER AW ACID WASTE INV INVERT AC AIR CHAMBER MC MECHANICAL CONTRACTOR ARCH ARCHITECT MFR MANUFACTURER B.T. BATH TUB N.C. NORMALLY CLOSED BPW BED PAN WASHER N.O. NORMALLY OPEN BLDG BUILDING NIC NOT IN CONTRACT C.A.P. COLLEGE OF AMERICAN PATHOLOGIST NTS NOT TO SCALE CI CAST IRON OD OUTSIDE DIAMETER CLG. CEILING PC PLUMBING CONTRACTOR CLDI CEMENT LINED DUCTILE IRON TYP TYPICAL CP CHROME PLATED VB VACUUM BREAKER CONT CONTINUATION SH SHOWER CS CUP SINK SK SINK DIA DIAMETER SS SOIL STACK DOV DRAIN OFF VALVE SPEC SPECIFICATION DWG DRAWING S.S. STAINLESS STEEL EA EACH VS VENT STACK EC ELECTRICAL CONTRACTOR VTR VENT THRU ROOF EL. ELEVATION VCP VITRIFIED CLAY PIPE EEW EMERGENCY EYE WASH WS WASTE STACK ESH EMERGENCY SHOWER W & T WASTE &TRAP EX, EXIST EXISTING W & V WASTE & VENT EJ EXPANSION JOINT WC WATER CLOSET FLR FLOOR XCW EXISTING DOMESTIC COLD WATER FT FOOT XHW EXISTING DOMESTIC HOT WATER GALV GALVANIZED XHWR EXISTING DOMESTIC HOT WATER RETURN GC GENERAL CONTRACTOR 1/2" HW INSTAHOT PLUMBING LEGEND HCO CW LL=1 -0 FCO HW - HWR - SANS SAN 11 i WCO 40 CTE DCV CAP OR END OF PIPE CHECK VALVE CLEANOUT COLD WATER CONNECT TO EXISTING ELBOW DOWN OR DROP ELBOW UP OR RISE EXISTING PIPING FIXTURE IDENTIFICATION FLOOR CLEANOUT HOT WATER HOT WATER RETURN SANITARY PIPING ABOVE FLOOR SANITARY PIPING BELOW FLOOR TEE LOOKING DOWN TEE LOOKING UP UNION VENT ABOVE GROUND VENT BURIED WALL CLEANOUT ISOLATION / SHUT-OFF VALVE DOUBLE CHECK VALVE HIVE SINK - UNDER COUNTER DETAIL SCALE: NONE )UNTERTOP /2" CW SUPPLY 1/2" WASTE IIIRianEaIEoil]IN PLUMBING NOTES 1. GENERAL NOTES, SYMBOLS LIST AND DETAILS ARE APPLICABLE TO ALL DRAWINGS MARKED P. 2. DRAWINGS ARE DIAGRAMMATIC: DETERMINE LOCATIONS OF SYSTEMS AND COMPONENTS IN FIELD. 3. PITCH PRESSURE PIPING IN DIRECTION OF FLOW. 4. DIMENSIONS SHOWN ON PLAN ARE HORIZONTAL. DIMENSIONS SHOWN IN ELEVATION ARE VERTICAL EXCEPT THAT, IN WAY OF STRUCTURAL DIMENSIONS ARE MEASURED PERPENDICULAR TO FLANGE. 5. NEITHER ACCURACY NOR COMPLETION OF UTILITY LOCATIONS SHOWN ON DRAWINGS IS GUARANTEED. DETERMINE EXACT LOCATIONS OF EXISTING UTILITIES IN FIELD, WHETHER OR NOT SHOWN ON DRAWINGS. EXERCISE CAUTION, AND IDENTIFY LOCATIONS OF UNMARKED UTILITY LINES AS NECESSARY TO PERFORM WORK OF THIS SECTION. 6. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH LOCAL AND STATE PLUMBING CODES AND DRAWINGS. 7. IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE HIS WORK WITH THAT OF ALL OTHER TRADES, INCLUDING (BUT NOT LIMITED TO), ELECTRICAL, HVAC, PROCESS PIPING, SPRINKLER, STRUCTURAL AND GENERAL ARCHITECTURE. 8. ANY INTERFERENCE SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER AND THE OWNER'S REPRESENTATIVE, AND SHALL BE RESOLVED PRIOR TO THE INSTALLATION OF THE WORK INVOLVED. 9. NO WORK SHALL BE INSTALLED IN VIOLATION OF ANY GOVERNING CODES. ANY WORK SHOWN ON THE DRAWINGS WHICH IS IN VIOLATION OF SUCH CODES SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER AND THE OWNER'S REPRESENTATIVE AND SHALL BE RESOLVED PRIOR TO THE INSTALLATION OF THE WORK INVOLVED. 10. ALL PIPING PENETRATING CEILINGS AND WALLS SHALL BE INSTALLED WITH CHROME (STAINLESS WHERE NOTED) PLATED ESCUTCHEONS AT THE PENETRATION. ALL PIPING PENETRATING EXTERIOR WALLS AND ROOFS SHALL BE FLASHED IN AN APPROVED MANNER AND SHALL BE SEALED WEATHERTIGHT. PIPING PENETRATING RATED PARTITIONS SHALL BE PROTECTED AS REQUIRED BY LOCAL CODE AUTHORITY. 11. MANUFACTURERS' MODEL NUMBERS ARE SPECIFIED SOLELY TO ESTABLISH STANDARDS OF QUALITY FOR PERFORMANCE AND MATERIALS. 12. PRODUCT INSTALLATION SHALL ADHERE TO MANUFACTURERS' RECOMMENDATIONS. 13. PROVIDE ACCESS PANELS FOR EQUIPMENT THAT REQUIRES PERIODIC SERVICE. 14. ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. 15. ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC., INSTALLED IN HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY. 16. 17. ALL SLEEVES THROUGH CONCRETE FLOORS AND ALL CORE DRILLING OF CONCRETE FLOORS AND WALLS SHALL BE BY THIS CONTRACTOR. 18. SCHEDULE WORK OF THIS SECTION TO AVOID INTERFERING WITH EXISTING STRUCTURE. 19. RUN PIPING CONCEALED, UNLESS SPECIFIED OTHERWISE, AND CLEAR OF CEILING INSERTS. 20. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS AND GUIDES AS NECESSARY TO PREVENT STRESS ON PIPING. 21. PROVIDE VENTS AT HIGH POINTS IN PIPING SYSTEMS AND DRAIN VALVES AT LOW POINTS. 22. VERIFY EXACT SIZES, LOCATIONS, INVERTS AND ELEVATIONS PRIOR TO RUNNING ANY PIPING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ALL FIXTURES AND EQUIPMENT. 23. PIPE SUPPORTS FOR PLUMBING SERVICE IN BUILDING SHAFTS ARE BY THIS CONTRACTOR. CAREFULLY COORDINATE WITH MISC. IRON CONTRACTOR PLACEMENT OF STEEL GRATE SUPPORT BEAMS. SHAFT PIPE SUPPORT SHALL BEAR FROM WALL AND FROM FLOOR SUPPORT BEAMS. 24. CONTRACTOR SHALL FIELD VERIFY CONNECTION TO EXISTING SANITARY. PLUMBING DEMOLITION NOTES THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE TO BE USED AS A GUIDELINE ONLY FOR THE SCOPE OF DEMOLITION WORK. THE PLUMBING CONTRACTOR SHALL VISIT THE PROJECT SITE DURING THE BID PHASE TO VERIFY THE EXACT CONDITIONS AND SCOPE OF WORK REQUIRED FOR A COMPLETE AND INCLUSIVE DEMOLITION PACKAGE. IT IS THE INTENT TO RE -USE EXISTING SYSTEMS AS NOTED WHERE PRACTICAL. 2. THE PLUMBING CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE CONTRACT DOCUMENTS AND TO HAVE SATISFIED HIMSELF AS TO THE CONDITIONS OF THE PREMISES, THE SITE, ANY OBSTRUCTIONS, THE ACTUAL FLOOR PLANS AND CONDITIONS, ACCESS PANELS, AND ALL OTHER EXISTING CONDITIONS. THE PLUMBING CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD, SHALL CHECK LOCATION OF AND CONNECTION TO EXISTING FACILITIES, AND SHALL ASSUME ALL RESPONSIBILITY FOR SAME. 3. ANY EXISTING EQUIPMENT, PIPING DEVICES BEING DISTURBED BY THE WORK SHALL BE REWORKED BY THIS CONTRACTOR AS REQUIRED TO RETURN TO ITS FORMER EXISTING OPERATING CONDITION. 4. THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE OWNER/BUILDING MANAGEMENT ALL INTERRUPTION OF SERVICES WITHIN THE AREA OF WORK AND BUILDING. 5. ALL EXISTING FIXTURES, DEVICES, EQUIPMENT, ETC. NOT INDICATED ON THE PLANS DRAWINGS SHALL BE CONSIDERED TO BE EXISTING TO REMAIN, UNLESS SPECIFICALLY NOTED OTHERWISE. 6. FOR ALL RENOVATION/REMOLDING WORK, INCLUDING ALL AREAS OF NO OR MINIMAL WORK, EXISTING PLUMBING SERVICES SHALL BE MAINTAINED TO FIXTURES, DEVICES, EQUIPMENT, OTHER PIPING, ETC. THAT ARE REQUIRED TO BE MAINTAINED. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THESE SERVICES, FIXTURES, DEVICES, EQUIPMENT, OTHER PIPING THAT ARE EXISTING TO REMAIN, WHETHER OR NOT INDICATED ON THE PLANS. 7. DISCONNECT AND REMOVE ALL EXISTING FIXTURES, DEVICES, EQUIPMENT, PIPING, ETC. LOCATED WITHIN THE AREA OF WORK INDICATED AS "TO BE REMOVED". CUT AND CAP ALL UNDER FLOOR AND UNDERGROUND PIPING PER LOCAL CODE REQUIREMENTS. 8. ALL FIXTURES, DEVICES, EQUIPMENT, PIPING, ETC. SHALL BE REMOVED COMPLETE, BACK TO SOURCE, SUCH AS SHUT OFF VALVES AND/OR METERING. 9. MAINTAIN ALL SERVICES IN ALL AREAS OF WORK AND SURROUNDING AREAS NOT IN DEMOLITION. 10. THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL, MECHANICAL HVAC, AND ELECTRICAL DEMOLITION DRAWINGS FOR ALL EQUIPMENT BEING DEMOLISHED, AND SHALL DISCONNECT AND REMOVE COMPLETE THE PLUMBING SERVICES TO ALL FIXTURES, DEVICES AND EQUIPMENT. 11. FIXTURES, DEVICES, AND EQUIPMENT INDICATED AS "XR", (EXISTING TO BE RELOCATED), SHALL BE STORED FOR RE -USE AS INDICATED BY "XN", (NEW LOCATION OF EXISTING DEVICE), ON NEW PLAN DRAWINGS. FIXTURES, DEVICES, AND EQUIPMENT SHALL BE CLEANED AND IN COMPLETE OPERATIONAL CONDITION UPON COMPLETION OF RE -INSTALLATION. 12. ALL CUTTING AND PATCHING OF WALLS, CEILINGS, OR FLOORS THAT ARE DISTURBED BY DEMOLITION SHALL BE RETURNED TO THEIR ORIGINAL CONDITION. REFER TO THE ARCHITECTURAL DOCUMENTS FOR EXACT SPECIFICATION REQUIREMENTS. PATCH FLOOR TO ORIGINAL CONSTRUCTION SPECIFICATIONS AND U.L. FIRE RATING LISTINGS FOR ALL FLOOR MOUNTED FIXTURES, DEVICES, AND EQUIPMENT WHICH HAVE BEEN REMOVED. 13. ALL EQUIPMENT AND/OR DEVICES THAT ARE REMOVED AND NOT RE -USED SHALL BE TURNED OVER TO OWNER/BUILDING MANAGEMENT OR DISPOSED OF PER THEIR DIRECTION. 14. ALL MATERIAL TO BE DISPOSED SHALL BE DONE UNDER STRICT ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL CODE REQUIREMENTS. I_ WASTE AND VENT PIPING Li IN WALL. SEE STACK DIAGRAM FOR SIZES PLUMBING FIXTURE SCHEDULE S-1 COUNTERTOP SINK: ELKAY SINGLE BOWL SINK LRADQ2219. 18 GAUGE TYPE 302 STAINLESS M E B STEEL, SELF RIMMING, THREE FAUCET HOLES, FULLY UNDERCOATED WITH LK35 STAINLESS AJM STEEL STRAINER AND 1-1/2" TAILPIECE, 1-1/2" CHROME PLATED CAST BRASS P -TRAP. "XR" FAUCET: SYMMONS SYMMETRICS S-23-3, POLISHED CHROME. SINGLE LEVER HANDLE, PULLOUT SPRAY HEAD. S-2 COUNTERTOP SINK: ELKAY ASANA SINGLE BOWL SINK LLVR1916. 18 GAUGE TYPE 304 STAINLESS STEEL, SELF RIMMING, THREE FAUCET HOLES, FULLY UNDERCOATED WITH LK35 STAINLESS STEEL STRAINER AND 1-1/2" TAILPIECE, 1-1/2" CHROME PLATED CAST BRASS "XM" P -TRAP. FAUCET: CHICAGO FAUCET 895-E35ABCP, POLISHED CHROME. LEVER HANDLES, WITH 0.5 GPM AERATOR E2605-5JKCP. IH -1 EEMAX MODEL SP3277, WALL MOUNTED, 277 VOLT/1 PHASE, 3.0 KW; TO HEAT JINSTA-HOT. 0.5 GPM AT A TEMPERATURE RISE OF 41 DEGREES F. PLUMBING FIXTURE CONNECTION SCHEDULE FIXTURE ISANITARYI VENT ICOLD WATERI HOT WATER IREMARKS SINK 1 2" 1 1-1/2" 1 1/2" 1 1/2" GENERAL PLUMBING NOTES 1. ALL "BUILDING STANDARDS" AND/OR "BUILDING SPECIFICATIONS" SHALL BE CONSIDERED AN INTEGRAL PART OF THESE DOCUMENTS AND THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN A COPY OF THESE DOCUMENTS AND COMPLY WITH ALL REQUIREMENTS, STANDARDS, AND SPECIFICATIONS CONTAINED WITHIN. 2. THESE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ARE INTENDED TO CONVEY THE SCOPE OF WORK AND INDICATE GENERAL ARRANGEMENT OF PIPING, FIXTURES, EQUIPMENT DEVICES, ETC. THE LOCATIONS OF ALL ITEMS SHOWN ON THESE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED AT THE PROJECT. ALL LOCATIONS OF WORK EXPOSED TO VIEW ARE SUBJECT TO APPROVAL OF THE ARCHITECT PRIOR TO ROUGH -INS. 3. ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE PROMPTLY BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION DURING THE BIDDING PERIOD. NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF HIS FAILURE TO HAVE BROUGHT SAID DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT/ENGINEER DURING THE BIDDING PERIOD OR OF ANY ERROR ON THE CONTRACTOR'S PART. 4. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT, PROFESSIONAL AND WORKMANLIKE MANNER, RECTILINEAR TO FINISHES AND BUILDING STRUCTURE. 5. REFER TO ARCHITECTURAL ELEVATIONS TO DERIVE EXACT LOCATIONS OF ALL RELATED EQUIPMENT, DEVICES, ETC. 6. THE PLUMBING CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT ALL NEW WORK WILL FIT INTO THE EXISTING STRUCTURE AND CONDITIONS IN THE MANNER INTENDED AND AS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/OWNERS REPRESENTATIVE PRIOR TO ANY ROUGH -INS, FABRICATIONS, OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A RFI, INCLUDING A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. 7. ALL PIPING RUNNING THROUGH BUILDING EXPANSION JOINTS SHALL BE EQUIPPED WITH APPROPRIATE EXPANSION FITTINGS. 8. ALL COMPONENTS SHOWN ON THE STACK AND OR RISER DIAGRAMS, BUT NOT ON THE PLAN OR VICE VERSA, SHALL BE INCLUDED AS IF SHOWN ON BOTH 9. THE PLUMBING CONTRACTOR SHALL REFER TO THE PLUMBING SPECIFICATIONS FOR ACCEPTABLE PIPING TYPES/LOCATIONS. 10. IT IS NOT INTENDED THAT THE PLANS INDICATE ALL OBSTRUCTIONS, NECESSARY BENDS, AND OFFSETS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL HIS WORK TO CONFORM TO CODE REQUIREMENTS, THE STRUCTURE, MAINTAIN HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR. REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AS REQUIRED. 11. IT IS NOT INTENDED THAT THE PLANS INDICATE ALL PIPING ROUTES, OFFSETS, TRANSITIONS, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING ACTUAL PIPE ROUTING, QUANTITY AND OFFSETS AND TRANSITIONS WITHIN ACCESSIBLE LOCATIONS. 12. SUPPORT ALL EQUIPMENT, AND PIPING FROM BUILDING STRUCTURE TO PROVIDE A VIBRATION FREE INSTALLATION. NOTIFY ARCHITECT AND STRUCTURAL ENGINEER OF ALL WEIGHTS AND METHODS OF SUPPORT PRIOR TO ANY ROUGH -INS OR INSTALLATIONS. 13. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, UNLESS NOTED OTHERWISE. 14. FIELD VERIFY THE EXACT LOCATION OF ANY PLUMBING EQUIPMENT THAT REQUIRES ELECTRICAL CONNECTIONS WITH RESPECTIVE CONTRACTORS. 15. REPAIR FIREPROOFING AFTER INSTALLATION OF HANGERS AND SUPPORTS TO ORIGINAL CONDITIONS. 16. MAINTAIN CODE AND MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES FOR EQUIPMENT. 17. ALL MATERIALS IN CEILING SPACE SHALL BE PLENUM RATED PER CODE. 18. DIMENSIONS SHOWN ON PLAN ARE HORIZONTAL. DIMENSIONS SHOWN IN ELEVATION ARE VERTICAL EXCEPT THAT, IN WAY OF STRUCTURAL DIMENSIONS ARE MEASURED PERPENDICULAR TO FLANGE. 19. NEITHER ACCURACY NOR COMPLETION OF UTILITY LOCATIONS SHOWN ON DRAWINGS IS GUARANTEED. DETERMINE EXACT LOCATIONS OF EXISTING UTILITIES IN FIELD, WHETHER OR NOT SHOWN ON DRAWINGS. EXERCISE CAUTION AND IDENTIFY LOCATIONS OF UNMARKED UTILITY LINES AS NECESSARY TO PERFORM WORK OF THIS SECTION. 20. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES. 21. ANY INTERFERENCE SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANGER, AND SHALL BE RESOLVED PRIOR TO THE INSTALLATION OF THE WORK INVOLVED. 22. ALL PIPING PENETRATING CEILINGS AND WALLS SHALL BE INSTALLED WITH CHROME(STAINLESS WHERE NOTED PLATED ESCUTCHEONS AT THE PENETRATION. ALL PIPING PENETRATING EXTERIOR WALLS AND ROOFS SHALL BE FLASHED IN AN APPROVED MANNER AND SHALL BE SEALED WEATHERTIGHT. PIPING PENETRATING RATED PARTITIONS SHALL BE PROTECTED AS REQUIRED BY LOCAL CODE AUTHORITY. 23. MANUFACTURERS' MODEL NUMBERS ARE SPECIFIED SOLELY TO ESTABLISH STANDARDS OF QUALITY FOR PERFORMANCE AND MATERIALS. 24. PRODUCT INSTALLATION SHALL ADHERE TO MANUFACTURERS' RECOMMENDATIONS. 25. TOPS OF ALL FLOOR DRAINS SHALL BE SET FLUSH WITH FINISHED FLOOR. 26. ALL PIPING ABOVE CEILINGS SHALL BE PROPERLY SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILINGS TILES OR CEILING STRUCTURE. 27. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL DRAWINGS, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES 1 PHASE SHOWN HEREIN. 28. ALL PLUMBING EQUIPMENT, PIPING INSULATION, ETC., INSTALLED IN HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY. 29. PROVIDE SHUTOFF VALVES ON ALL BRANCH PIPING AND ON ALL SUPPLIES TO INDIVIDUAL FIXTURES AND EQUIPMENT. PROVIDE BALL VALVES ON ALL WATER MAIN BRANCHES IN CORRIDORS AND WHERE INDICATED ON DRAWINGS. ALL VALVES SHALL BE ACCESSIBLE. PROVIDE VALVES AT RACK FOR RO/DI ONLY. VALVES FOR RO/DI BRANCH PIPING SHALL BE LOCATED NOT MORE THAN 6 PIPE DIAMETERS FROM MAIN TO CENTERLINE OF VALVE. 30. ALL SLEEVES THROUGH CONCRETE FLOORS AND ALL CORE DRILLING OF CONCRETE FLOORS AND WALLS SHALL BE BY THIS CONTRACTOR. 31. CONCRETE PADS AND PLATFORMS FOR WORK OF THIS SECTION WILL BE PROVIDED BY GENERAL CONTRACTOR. PROVIDE INFORMATION AND HARDWARE AS NECESSARY TO GENERAL CONTRACTOR TO COORDINATE WORK. 32. SCHEDULE WORK OF THIS SECTION TO AVOID INTERFERING WITH FIRE -PROOFING WORK. 33. COORDINATE ROOF PENETRATIONS WITH WORK OF ALL JOB TRADES AND WITH FLASHING REQUIREMENTS. 34. PLUMBING CONTRACTOR SHALL FIELD VERIFY SANITARY INVERTS PRIOR TO FABRICATION OR INSTALLATION OF PLUMBING. CONTACT ENGINEER IMMEDIATELY IF THERE IS A DISCREPANCY. 35. RUN PIPING CONCEALED, UNLESS SPECIFIED OTHERWISE, AND CLEAR OF CEILING INSERTS. 36. STRUCTURAL WELDING SHALL BE 1/4 INCH FILLET UNLESS REQUIRED OTHERWISE. 37. PROVIDE CLAMPS, OFFSETS, EXPANSION JOINTS, ANCHORS AND GUIDES AS NECESSARY TO PREVENT STRESS ON PIPING. 38. PROVIDE BALANCING VALVES AT SYSTEM LOOP RETURNS AND AT RETURN RISERS, PROVIDE SHUT-OFF VALVES AT SYSTEM LOOP SUPPLIES AND SUPPLY RISERS. 39. PROVIDE VENTS AT HIGH POINTS IN PIPING SYSTEMS AND DRAIN VALVES AT LOW POINTS. 40. PITCH PRESSURE PIPING IN DIRECTION OF FLOW. 41. VERIFY EXACT SIZES, LOCATIONS, INVERTS AND ELEVATIONS PRIOR TO RUNNING ANY PIPING. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ALL FIXTURES AND EQUIPMENT. REFER TO KITCHEN LAYOUT DRAWING FOR EXACT LOCATION AND ROUGH -IN REQUIREMENTS OF ALL KITCHEN FIXTURES AND EQUIPMENT. 42. PIPE SUPPORTS FOR PLUMBING & FIRE SERVICE IN BUILDING SHAFTS ARE BY THIS CONTRACTOR. CAREFULLY COORDINATE WITH MISC. IRON CONTRACTOR PLACEMENT OF STEEL GRATE SUPPORT BEAMS. SHAFT SUPPORT SHALL BEAR FROM WALL AND FROM FLOOR SUPPORT BEAMS. 43. GENERAL FLOOR CONTROL VALVES OF PIPED SERVICES SHALL BE IN THE PIPE SHAFTS UNLESS OTHERWISE INDICATED. 44. ALL WASTE PIPING FROM LAB SINKS & HOODS SHALL BE VALVED IN BASE CABINET OF HOOD. NO CONNECTION TO LAB WASTE OR LAB VENT PIPING SYSTEM SHALL BE MADE. 45. ALL HORIZONTAL RAIN WATER PIPING IN EXTERIOR STAIRWELLS TO BE HEAT TRACED AND INSULATED AS SPECIFIED. 46. WATER HEATERS SHALL BE INSTALLED WITH DRAIN PANS UNDER HEATERS. ROUTE PAN DRAINS TO NEAREST FLOOR DRAIN OR SAFE DRAIN. 47. PIPING SHALL NOT RUN OVER ELECTRICAL PANELS AND SHALL BE COORDINATED WITH WORK OF OTHER TRADES. DEMOLITION ANNOTATION LEGEND "X" DENOTES EXISTING FIXTURE/EQUIPMENT/PIPING TO BE REMOVED IN ITS ENTIRETY INCLUDING M E B BRANCH DOMESTIC WATER, SANITARY AND VENT PIPING BACK TO SOURCE OR NEXT ACTIVE AJM DEVICE OR PIPING BEING MAINTAINED. "XR" DENOTES EXISTING FIXTURE/EQUIPMENT/PIPING TO BE RELOCATED IN ITS ENTIRETY. RELOCATION TO NEW LOCATION ("XN") IS INDICATED ON "NEW WORK" DRAWINGS. "XN" DENOTES NEW LOCATION OF EXISTING RELOCATED ("XR") FIXTURE/EQUIPMENT/PIPING. REWORK OR PROVIDE NEW DOMESTIC WATER, SANITARY, VENT PIPING, ETC. TO NEW LOCATION AS REQUIRED/INDICATED. "XM" DENOTES EXISTING FIXTURE/EQUIPMENT/PIPING TO BE MAINTAINED. Z a a II II II II II J II -FINISH FLOOR a a < a I WASTE AND VENT PIPING LJ IN WALL. SEE STACK DIAGRAM FOR SIZES MOTHERS ROOM SINK- UNDER COUNTER DETAIL SCALE: NONE /_ / i i i � tii 1-1 i" �-1 I 'b .10 / �� I 1-1 1-1 I I-,-, I CO -,1-1 \e< 1 ?J,\ 1-1 3sq- � S5=2 N� 1 N%%%" 3s4 1 � 1 S-1 \ I SANITARY STACK DIAGRAM SCALE: NONE • Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc ```00 �RA VBAIIr '',•,, zZ/P. \. - \5 TFR�;A ��4 0 No. 11400468 __ 0'. �•_ = -o % STATE OF ;I � , V"�, n %,%, �6 11 X% OVD11 We', nus 114111 HELLYER Drawn by: M E B LEWIS= AJM Approved by: AJM ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. PhiIa., PA 1 91 07 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: . t, Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Plumbing Schedules, Legends and Notes No. P-0.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision Scale: 1/8" = 1'-0" Drawing: Plumbing Schedules, Legends and Notes No. P-0.04 PLUMBING PLAN GENERAL NOTES: 1. PLUMBING CONTRACTOR SHALL PERFORM A FIELD SURVEY PRIOR TO FABRICATING OR INSTALLING ANY NEW WORK OR MODIFYING EXISTING. NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES FOUND FOR DIRECTION PRIOR TO PROCEEDING. 2. ANY EXISTING SYSTEMS NOTED AS EXISTING TO REMAIN SHALL BE FIELD VERIFIED FOR DEFICIENCIES. 3. PLUMBING CONTRACTOR SHALL COORDINATE ANY NECESSARY SHUTDOWNS WITH UTILITIES AND BUILDING/ADJACENT TENANTS. 4. PLUMBING CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS REQUIRED FOR THEIR TRADE. SEE ARCHITECTURAL DRAWINGS FOR SPECIFICATIONS. 5. ROUTE PLUMBING AS HIGH AS POSSIBLE THROUGHOUT SPACE. 6. PLUMBING CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND PREPARE INTERFERENCE DRAWINGS FOR SUBMITTAL, PRIOR TO ANY FABRICATION OR INSTALLATION. RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes ICltp at Caimal ntro DATE: 02/23/18 • Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc A 13A STF�'A���'': '4 O No. 11400468 = •� • - Plumbing Plan SCALE: 1/$., = -o., PLUMBING PLAN CODED NOTES: (D Di INSTALL COLD WATER CONNECTION WITH ICE BOX IPS MODEL AB9700 ICE MAKER OUTLET BOX WITH 1/4" LLDPE TUBING AND 1/4 TURN VALVE TO REFRIGERATOR. O EXTEND 1/2" CW TO COUNTER FOR COFFEE STATION WITH BACKFLOW PREVENTER, WATTS MODEL 7. PROVIDE WITH ANGLE STOP VALVE AND 1/4" LLDPE TUBING AT COFFEE MACHINE. SEE DETAIL ON SHEET PO.1. O3 REMOVE AND DISCARD EXISTING PLUMBING DRAIN. CAP AT CONNECTION TO MAIN. ® CONNECT TO EXISTING BUILDING SANITARY AND VENT. FIELD VERIFY EXACT LOCATION AND ROUTING. O5 CONNECT TO EXISTING BUILDING HOT AND COLD WATER. FIELD VERIFY EXACT LOCATION AND ROUTING. N H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT— OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Plumbing Plan No. P-1.04 Drawn by: M E B Checked by: AJM Approved by: AJM Client Approval: Date: Issue Date: 01/26/18 Issue For Permit: 01/29/18 No. Date Revision --r i Scale: 1/8" = V-0" Drawing: Plumbing Plan No. P-1.04