E-0.04
LUMINAIRE SCHEDULE SYMBOL LAMPS CR CARD READER FM`51 MANUFACTURER FD_1B1 TYPE ES WATTAGE VOLTAGE DESCRIPTION AND CATALOG REMARKS C O b RECEPTACLE SYMBOL WITH ADDITIONAL SUBSCRIPT DESIGNATES TYPE OR SPECIFIC ABOVE FINISH GRADE No. TYPE "AC" INDICATES MOUNTED 8" ABOVE COUNTER UNLESS NOTED OTHERWISE ON $X ARCHITECTURAL ELEVATIONS NUMBER +48 RECEPTACLE MOUNTED AT HEIGHT INDICATED Q JUNCTION BOX - SIZE PER N.E.C. ARTICLE 314 REQUIREMENTS ® NEMA L14 -30R RECEPTACLE ® L.E.D. 2'x4' LAY -IN WITH CURVED CENTER SATINE LENS, WHITE FINISH, AND STANDARD PINNACLE: THREE(3) STUBBED CONDUITS FOR POWER, DATA AND AV. FIRE SAFE TO ORIGINAL FLOOR A - LED 3500'K 41 UNV 0-10V DIMMING DRIVER. #AD24-A-835HO-XX-U-OL1 -1 -0-W POWER: ONE 1/2" CONDUIT STUB. OS DATA: ONE 3/4" CONDUIT STUB MOTOR CONTROL CENTER AV: ONE 1-1/4" CONDUIT STUB AUTOMATIC TRANSFER SWITCH 6" 2 HOUR FIRE RATED POKE THROUGH: LEGRAND WIREMOLD #6AT SERIES WITH ONE(1) SIDE O COMPARTMENT MOUNTED 125VAC-20AMP DUPLEX RECEPTACLE #68REC WITH BOTTOM FEED AUTOMATIC TEMPERATURE CONTROL 1/2 GANG 3/4" CONDUIT HOUSING ASSEMBLY #575CHA, ONE(1) CENTER COMPARTMENT MISCELLANEOUS MOUNTED EIGHT(8) PORT COMMUNICATIONS DEVICE PLATE #6ACT8A AND ONE(1) SIDE AMERICAN WIRE GAUGE SAME AS TYPE "A", EXCEPT WITH SELF CONTAINED EMERGENCY LIGHTING BATTERY PACK. PINNACLE: CONDUIT BOTTOM HOUSING #1100CHA AND HALF GANG BLANK BOTTOM HOUSING #SBLH. AE _ LED 3500'K 41 UNV AS INDICATED ON PLAN. PROVIDE CONDUIT WITH PULLSTRING AND INSULATING BUSHING. #AD24-A-835HO-XX-U-OL1-1-11-W WALL MOUNTED POWER OUTLET (4-11/16" SQUARE x 2-1/8" DEEP JUNCTION BOX) BUILDING MANAGEMENT SYSTEM COMPLETE WITH SINGLE GANG DEVICE RING AND COVER PLATE(COLOR SELECTION BY ASSOCIATION ARCHITECT) TO ACCEPT FURNITURE WHIP. PROVIDE ALL NECESSARY APPURTENANCES CONDUIT INCLUDING WHIP IF REQUIRED AND MAKE FINAL CONNECTIONS TO SYSTEMS FURNITURE. MOUNT NATIONAL FIRE PROTECTION ASSOCIATION AT 8" A.F.F. UNLESS NOTED OTHERWISE. (Ti WALL MOUNTED TELECOMMUNICATIONS JUNCTION BOX FOR CONNECTION TO SYSTEMS NOT IN CONTRACT FURNITURE. JUNCTION BOX SHALL BE 4-11/16" SQUARE x 3" DEEP COMPLETE WITH SINGLE CABINET UNIT HEATER SAME AS TYPE "A", EXCEPT 2'x2' PINNACLE: STUBBED 12" INTO ACCESSIBLE CEILING SPACE. MOUNT AT 8" A.F.F. UNLESS NOTED Al- OTHERWISE. LED 3500'K 20 UNV FLUSH FLOOR MOUNTED POWER AND TELECOM FIRE RATED POKE -THROUGH #AD22-A-835LO-XX-U-OL1-1-0-W DEVICE WITH FURNITURE FEED COVER PLATE. HUBBELL SYSTEM ONE "FRPT" - 4 CIRCUIT INCH, ONE PIECE POKE -THROUGH WITH 3/4" CONDUIT STEM FOR POWER AND NOT TO SCALE 1-1/2" CONDUIT STEM FOR VOICE/DATA; #S1SPFFXX COVER PLATE. PROVIDE CENTERLINE ONE 1-1/2" CONDUIT (FOR TELECOM) BELOW FLOOR TO NEAREST WALL AND POLE EXTEND TO 12" ABOVE ACCESSIBLE CEILING OF FLOOR. VERIFY COVER PLATE CURRENT LIMITING FUSE COLOR WITH ARCHITECT. ®T SAME AS 00, EXCEPT ONLY 1-1/2" VOICE/DATA CONDUIT UTILIZED. OS SAME AS TYPE "Al ", EXCEPT WITH SELF CONTAINED EMERGENCY LIGHTING BATTERY PACK. PINNACLE: CPT A E - LED 3500K 20 UNV PT #AD22-A-835LO-XX-U-OL1-1-1I-W CU COPPER PVC POLYVINYL CHLORIDE EF EXHAUST FAN RMC RIGID METAL CONDUIT EM EMERGENCY RMS ROOT MEAN SQUARED EMT ELECTRICAL METALLIC TUBING L.E.D. 6" DIAMETER RECESSED DOWNLIGHT WITH CLEAR SEMI SPECULAR H.E. WILLIAMS: EPO C - LED 3500'K 19 UNV REFLECTOR WITH WIDE DISTRIBUTION AND STANDARD DRIVER. #L60-Ll5C-835-CS-W-DRV-277 EWC ELECTRIC WATER COOLER SP SPARE F FUSE SWD SWITCH DUTY (RATED) FCU FAN COIL UNIT SYM SYMMETRICAL FLA FULL LOAD AMPERES SAME AS TYPE "C", EXCEPT WITH SELF CONTAINED EMERGENCY LIGHTING BATTERY PACK. H.E. WILLIAMS: FMC FLEXIBLE METAL CONDUIT TMCB LED FNMC FLEXIBLE NON-METALLIC CONDUIT TMGB #L60-Ll5C-835-CS-W-DIM-277-EM/12W FT CE _ 350D 19 277 UH UNIT HEATER GND, G GROUND OR GROUNDING UL UNDERWRITERS LABORATORIES GRMC GALVANIZED RIGID METALLIC CONDUIT SAME AS TYPE "C", EXCEPT WITH DIMMING DRIVER. H.E. WILLIAMS: HACR CD _ LED 350D 19 277 W #L60-Ll5C-835-CS-W-DIM-277 HOA HAND, OFF, AUTOMATIC SWITCH WH WATER HEATER IEEE INSTITUTE OF ELECTRICAL & ELECTRONIC INCANDESCENT PENDANT MOUNT WITH "SPIRAL NEST" SHADE. WHITE CANOPY RIDGELY STUDIO WERKS: VERIFY CORD LENGTH WITH ARCHITECT D 1 60 T10 60 120 AND CORD SET AND GREEN FINISH. #SPIRAL NEST IN INCHES WYE INT INTERLOCK 0 PHASE K KILO/THOUSAND KCMIL THOUSAND CIRCULAR MILS L.E.D. SELF POWERED BATTERY BACK-UP DIE CAST ALUMINUM EXIT SIGN. BRUSHED CHLORIDE: ALUMINUM FACE WITH BLACK HOUSING AND RED LETTERING. MOUNTING CONFIGURATION, # CAD -N -U -R -A }e� - LED 4 120/277 FACES AND DIRECTIONAL ARROWS AS INDICATED ON PLANS. 1. THE ELECTRICAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO COORDINATE AND VERIFY WITH THE ARCHITECT AND ALL ARCHITECTURAL DRAWINGS SUCH AS FLOOR PLANS CEILING PLANS SCHEDULES ELEVATIONS SECTIONS DETAILS ETC., ALL CEILING TYPES, CONFIGURATIONS AND SPECIFICATIONS, LUMINAIRE COLORS AND FINISHES, LENGTHS, TRIMS, MOUNTINGS, MOUNTING SYSTEMS/HARDWARE, LUMINAIRE CONFIGURATIONS/STYLES/SHAPES, HEIGHT OF SUSPENDED AND WALL MOUNTED LUMINAIRES, ETC. PRIOR TO SHOP DRAWING SUBMITTALS, ANY ROUGH -INS, AND PLACING FINAL PURCHASE ORDERS. . 2. VERIFY FINAL LUMINAIRE LOCATIONS WITH OTHER CEILING MOUNTED EQUIPMENT SUCH AS DIFFUSERS, FIRE ALARM DEVICES, SPEAKERS, ETC. WITH ARCHITECTURAL RCP (REFLECTED CEILING PLANS). 3. VERIFY EXACT HEIGHT AND LOCATIONS OF ALL WALL MOUNTED AND PENDANT/CABLE MOUNTED LUMINAIRES WITH ARCHITECTURAL ELEVATIONS PRIOR TO ANY ROUGH -IN. 4. LUMINAIRES SHALL NOT BE SUPPORTED FROM SUSPENDED CEILING SUPPORTS UNLESS ADDITIONAL CEILING FRAMING AND SUPPORTS ARE ADDED BY THE CEILING CONTRACTOR ACCORDING TO MANUFACTURER'S RECOMMENDATIONS, U.L. LISTINGS, AND ANY APPLICABLE STATE OR LOCAL CODES. 5. CONNECTIONS TO RECESSED LUMINAIRES SHALL BE MADE WITH MINIMUM 1/2" FLEXIBLE METAL CONDUIT (FMC) FROM FIXTURE TO OUTLET BOX. LENGTH OF FMC SHALL NOT EXCEED 6'. 6. AT THE CONCLUSION OF THE WORK, EACH LUMINAIRE MUST BE CLEANED PER MANUFACTURER'S INSTRUCTIONS, EQUIPPED WITH THE PROPER TYPE, NUMBER OF LAMPS, INCLUDING KELVIN TEMPERATURE AND WATTAGE, AND ALL IN GOOD OPERATING CONDITION. DOOR ACCESS CONTROL SYMBOL LEGEND SYMBOL DESCRIPTION CR CARD READER FM`51 MOTION DETECTOR FD_1B1 DOOR BELL ES ELECTRIC STRIKE RELEASED IFCR CONSTRUCTION Suubjecktio aompdiianme with ®III regofatimms of State and Uncal Endes ICltp at Caimal ntro DATE: 02/23/18 TELECOMMUNICATION OUTLET SYMBOL LEGEND SYMBOL I DESCRIPTION V COMBINATION VOICE/DATA OUTLET (4-11/16" x 2-1/8" DEEP JUNCTION BOX) COMPLETE WITH SINGLE GANG DRY WALL RING (VERIFY DRYWALL THICKNESS) MOUNTED AT 18" A.F.F. PROVIDE 3/4" CONDUIT WITH INSULATING BUSHING AND PULLSTRING STUBBED UP 12" INTO ACCESSIBLE CEILING SPACE. V VOICE (TELEPHONE) OUTLET (4-11/16" x 2-1/8" DEEP JUNCTION BOX) COMPLETE WITH SINGLE GANG DRY WALL RING (VERIFY DRYWALL THICKNESS) MOUNTED AT 18" A.F.F. PROVIDE 3/4" CONDUIT WITH INSULATING BUSHING AND PULLSTRING STUBBED UP 12" INTO ACCESSIBLE CEILING SPACE. 0 DATA OUTLET (4-11/16" x 2-1/8" DEEP JUNCTION BOX) COMPLETE WITH SINGLE GANG DRY WALL RING (VERIFY DRYWALL THICKNESS) MOUNTED AT 18" A.F.F. PROVIDE 3/4" CONDUIT WITH INSULATING BUSHING AND PULLSTRING STUBBED UP 12" INTO ACCESSIBLE CEILING SPACE. FAV71 SINGLE GANG MUD RING WITH TWO PULL STRINGS AT 18" AFF WITH 1-1/4" CONDUIT TO THE FLOOR STUB BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED FACEPLATES. AV2 CHIEF MFG. PAC526 WITH TWO PULL STRINGS WITH 1-1/4" CONDUIT TO THE PLENUM. BOX BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED FACEPLATES. MOUNTING HEIGHT AS INDICATED ON PLANS. VOICE AND/OR DATA SYMBOL WITH ADDITIONAL SUBSCRIPT DESIGNATES TYPE OR SPECIFIC REQUIREMENTS AS FOLLOWS: "AC" INDICATES MOUNTED 8" ABOVE COUNTER UNLESS NOTED OTHERWISE ON ARCHITECTURAL ELEVATIONS "+48" SPECIFIC MOUNTING HEIGHT OF DEVICE "TV" DENOTES TELEVISION OUTLET ® TELECOMMUNICATION BACKBOARD - 3/4" PLYWOOD - 8'-0" HIGH x LENGTH OF WALL AS INDICATED - PAINTED WITH TWO COATS OF FIRE RESISTANT PAINT ON ALL SIX SIDES WIRING DEVICE SYMBOL LEGEND SYMBOL DESCRIPTION 6 DUPLEX RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDING TYPE MOUNTED ABOVE COUNTER AT 18" AFF UNLESS NOTED OTHERWISE ° DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, GROUNDING TYPE Al MOUNTED AT 18" AFF UNLESS NOTED OTHERWISE KILOWATTS GFCI GROUND TYPE DUPLEX RECEPTACLE - 125 VOLT, 20 AMPERE, 2 POLE, 3 WIRE, ABOVE FINISH FLOOR GROUNDING TYPE MOUNTED AT 18" AFF UNLESS NOTED OTHERWISE C O b RECEPTACLE SYMBOL WITH ADDITIONAL SUBSCRIPT DESIGNATES TYPE OR SPECIFIC ABOVE FINISH GRADE REQUIREMENTS AS FOLLOWS: LIGHTING "AC" INDICATES MOUNTED 8" ABOVE COUNTER UNLESS NOTED OTHERWISE ON $X ARCHITECTURAL ELEVATIONS LIQUID TIGHT FLEXIBLE METAL CONDUIT +48 RECEPTACLE MOUNTED AT HEIGHT INDICATED Q JUNCTION BOX - SIZE PER N.E.C. ARTICLE 314 REQUIREMENTS ® NEMA L14 -30R RECEPTACLE ® NEMA L6 -20R RECEPTACLE - THREE(3) STUBBED CONDUITS FOR POWER, DATA AND AV. FIRE SAFE TO ORIGINAL FLOOR ALUMINUM CONSTRUCTION AND FIRE RATING AS REQUIRED IN ACCORDANCE WITH ARCHITECTURAL MAIN CIRCUIT BREAKER SPECIFICATIONS. COORDINATE LOCATION WITH ARCHITECT AND FURNITURE VENDOR PRIOR TO AMERICAN NATIONAL STANDARDS INSTITUTE CORING FOR COORDINATION WITH THE TABLE LEG.. MOLDED CASE CIRCUIT BREAKER POWER: ONE 1/2" CONDUIT STUB. OS DATA: ONE 3/4" CONDUIT STUB MOTOR CONTROL CENTER AV: ONE 1-1/4" CONDUIT STUB AUTOMATIC TRANSFER SWITCH 6" 2 HOUR FIRE RATED POKE THROUGH: LEGRAND WIREMOLD #6AT SERIES WITH ONE(1) SIDE O COMPARTMENT MOUNTED 125VAC-20AMP DUPLEX RECEPTACLE #68REC WITH BOTTOM FEED AUTOMATIC TEMPERATURE CONTROL 1/2 GANG 3/4" CONDUIT HOUSING ASSEMBLY #575CHA, ONE(1) CENTER COMPARTMENT MISCELLANEOUS MOUNTED EIGHT(8) PORT COMMUNICATIONS DEVICE PLATE #6ACT8A AND ONE(1) SIDE AMERICAN WIRE GAUGE COMPARTMENT MOUNTED BLANK MOUNTING PLATE #68B WITH BOTTOM FEED ONE GANG 1" MAIN LUGS ONLY CONDUIT BOTTOM HOUSING #1100CHA AND HALF GANG BLANK BOTTOM HOUSING #SBLH. BUILDING AUTOMATION SYSTEM PROVIDE WITH SURFACE STYLE COVER ASSEMBLY #6CTC2XX. FINISH COLOR BY ARCHITECT. NATIONAL ELECTRIC CODE PROVIDE 12" RADIUS 2" CONDUIT ELBOW AND RUN CONDUIT IN WALL TO 6" ABOVE CEILING BELOW FINISH GRADE AS INDICATED ON PLAN. PROVIDE CONDUIT WITH PULLSTRING AND INSULATING BUSHING. (Pi WALL MOUNTED POWER OUTLET (4-11/16" SQUARE x 2-1/8" DEEP JUNCTION BOX) BUILDING MANAGEMENT SYSTEM COMPLETE WITH SINGLE GANG DEVICE RING AND COVER PLATE(COLOR SELECTION BY ASSOCIATION ARCHITECT) TO ACCEPT FURNITURE WHIP. PROVIDE ALL NECESSARY APPURTENANCES CONDUIT INCLUDING WHIP IF REQUIRED AND MAKE FINAL CONNECTIONS TO SYSTEMS FURNITURE. MOUNT NATIONAL FIRE PROTECTION ASSOCIATION AT 8" A.F.F. UNLESS NOTED OTHERWISE. (Ti WALL MOUNTED TELECOMMUNICATIONS JUNCTION BOX FOR CONNECTION TO SYSTEMS NOT IN CONTRACT FURNITURE. JUNCTION BOX SHALL BE 4-11/16" SQUARE x 3" DEEP COMPLETE WITH SINGLE CABINET UNIT HEATER GANG DEVICE RING AND 1-1/2" CONDUIT WITH INSULATING BUSHING AND PULLSTRING NORMALLY CLOSED STUBBED 12" INTO ACCESSIBLE CEILING SPACE. MOUNT AT 8" A.F.F. UNLESS NOTED CIRCUIT BREAKER OTHERWISE. ©T POWER AND TELECOM FURNITURE FEED FLOOR BOX FIRE RATED OR POKE -THROUGH DEVICE. CERTIFIED BALLASTS MANUFACTURERS FLUSH FLOOR MOUNTED POWER AND TELECOM FIRE RATED POKE -THROUGH NORMALLY OPEN DEVICE WITH FURNITURE FEED COVER PLATE. HUBBELL SYSTEM ONE "FRPT" - 4 CIRCUIT INCH, ONE PIECE POKE -THROUGH WITH 3/4" CONDUIT STEM FOR POWER AND NOT TO SCALE 1-1/2" CONDUIT STEM FOR VOICE/DATA; #S1SPFFXX COVER PLATE. PROVIDE CENTERLINE ONE 1-1/2" CONDUIT (FOR TELECOM) BELOW FLOOR TO NEAREST WALL AND POLE EXTEND TO 12" ABOVE ACCESSIBLE CEILING OF FLOOR. VERIFY COVER PLATE CURRENT LIMITING FUSE COLOR WITH ARCHITECT. ®T SAME AS 00, EXCEPT ONLY 1-1/2" VOICE/DATA CONDUIT UTILIZED. OS CEILING MOUNTED SPEAKER LIGHTING SYMBOL LEGEND SYMBOL DESCRIPTION A AC ABOVE COUNTER RECESSED 2'x4' LUMINAIRE. "A" INDICATES TYPE; "a" INDICATES SWITCH CONTROL. REFER TO ° LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION. Al KW KILOWATTS RECESSED 2'x2' LUMINAIRE. "Al" INDICATES TYPE. REFER TO LUMINAIRE SCHEDULE FOR ABOVE FINISH FLOOR ADDITIONAL INFORMATION. C O b RECESSED DOWN LIGHT. "C" INDICATES LUMINAIRE TYPE; "b" INDICATES SWITCH CONTROL ABOVE FINISH GRADE REFER TO LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION. LIGHTING LIGHT SWITCH. SINGLE POLE, 20 AMPERE, 120/277 VOLT, 1 HP. $X LIGHT SWITCH. "X" INDICATES THE FOLLOWING: LIQUID TIGHT FLEXIBLE METAL CONDUIT "a" CONTROL OF INDICATED LUMINAIRES AIR HANDLING UNIT "VD" WALLBOX PIR VAVANCY SENSOR WITH 0-10V DIMMING AND AMBIENT LIGHT MAKE-UP AIR UNIT DETECTION SENSOR. LUTRON #MS -Z101 -V -WH AMPERE INTERRUPTING CAPACITY 'VS" WALLBOX DUAL TECHNOLOGY VACANCY SENSOR WITH AMBIENT LIGHT DETECTION. METAL CLAD (CABLE) LUTRON MAESTRO #MS -A102 -V -WH ALUMINUM "OS" WALLBOX DUAL TECHNOLOGY OCCUPANCY SENSOR WITH AMBIENT LIGHT DETECTION. MAIN CIRCUIT BREAKER LUTRON MAESTRO #MS -A102 -WH AMERICAN NATIONAL STANDARDS INSTITUTE "D" TWO BUTTON WALL SWITCH WITH RAISE/LOWER (BRIGHTEN/DIM) CONTROL. MOLDED CASE CIRCUIT BREAKER LUTRON SEETOUCH QS #QSW52-2BRLI-WH OS CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR. MOTOR CONTROL CENTER LUTRON #LOS -CDT -2000 -WH WITH POWER PACK #PP -DV AUTOMATIC TRANSFER SWITCH CEILING MOUNTED WIRELESS DAYLIGHT SENSOR. DS LUTRON RADIO POWR SAVR #LRF2-DCRB-WH ABBREVIATIONS A, AMP AMPERES KVA KILOVOLT AMPERES AC ABOVE COUNTER KV KILOVOLT ADA AMERICANS WITH DISABILITIES ACT KW KILOWATTS AFF ABOVE FINISH FLOOR LED LIGHT EMITTING DIODE AFG ABOVE FINISH GRADE LTG LIGHTING AHJ AUTHORITY HAVING JURISDICTION LFMC LIQUID TIGHT FLEXIBLE METAL CONDUIT AHU AIR HANDLING UNIT MAU MAKE-UP AIR UNIT AIC AMPERE INTERRUPTING CAPACITY MC METAL CLAD (CABLE) AL ALUMINUM MCB MAIN CIRCUIT BREAKER ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MCCB MOLDED CASE CIRCUIT BREAKER ATO AUTOMATIC THROW OVER SWITCH MCC MOTOR CONTROL CENTER ATS AUTOMATIC TRANSFER SWITCH MCP MOTOR CIRCUIT PROTECTOR ATC AUTOMATIC TEMPERATURE CONTROL MISC MISCELLANEOUS AWG AMERICAN WIRE GAUGE MLO MAIN LUGS ONLY BAS BUILDING AUTOMATION SYSTEM NEC NATIONAL ELECTRIC CODE BFG BELOW FINISH GRADE NEMA NATIONAL ELECTRICAL MANUFACTURES BMS BUILDING MANAGEMENT SYSTEM ASSOCIATION C CONDUIT NFPA NATIONAL FIRE PROTECTION ASSOCIATION CAT CATALOG NIC NOT IN CONTRACT CUH CABINET UNIT HEATER N.C. NORMALLY CLOSED CB CIRCUIT BREAKER NMSC NON-METALLIC SHEATHED CABLE CBM CERTIFIED BALLASTS MANUFACTURERS N.O. NORMALLY OPEN CKT CIRCUIT NTS NOT TO SCALE CL CENTERLINE P POLE CLF CURRENT LIMITING FUSE PB PUSH-BUTTON COL COLUMN PNL PANEL CPT CONTROL POWER TRANSFORMER POS POINT OF SALES CT CURRENT TRANSFORMER PT POTENTIAL TRANSFORMER CU COPPER PVC POLYVINYL CHLORIDE EF EXHAUST FAN RMC RIGID METAL CONDUIT EM EMERGENCY RMS ROOT MEAN SQUARED EMT ELECTRICAL METALLIC TUBING RNMC RIGID NONMETALLIC CONDUIT EPO EMERGENCY POWER OFF RTU ROOF TOP UNIT ETR EXISTING TO REMAIN SCH SCHEDULE EWC ELECTRIC WATER COOLER SP SPARE F FUSE SWD SWITCH DUTY (RATED) FCU FAN COIL UNIT SYM SYMMETRICAL FLA FULL LOAD AMPERES TGB TELEPHONE GROUNGING BAR FMC FLEXIBLE METAL CONDUIT TMCB THERMAL MAGNETIC CIRCUIT BREAKER FNMC FLEXIBLE NON-METALLIC CONDUIT TMGB TELEPHONE MAIN GROUNDING BAR FT FEET U/G UNDERGROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER UH UNIT HEATER GND, G GROUND OR GROUNDING UL UNDERWRITERS LABORATORIES GRMC GALVANIZED RIGID METALLIC CONDUIT UNO UNLESS NOTED OTHERWISE HACR HEATING, AIR CONDITIONING, REFRIGERATION V VOLT HID HIGH INTENSITY DISCHARGE W WIRE HOA HAND, OFF, AUTOMATIC SWITCH WH WATER HEATER IEEE INSTITUTE OF ELECTRICAL & ELECTRONIC WP WEATHER PROOF ENGINEERS XFMR TRANSFORMER IMC INTERMEDIATE METAL CONDUIT A DELTA IN INCHES WYE INT INTERLOCK 0 PHASE K KILO/THOUSAND KCMIL THOUSAND CIRCULAR MILS CIRCUITING AND RACEWAY LEGEND SYMBOL DESCRIPTION H,�G HP2/7 HOME RUN TO PANEL "HP2", CIRCUIT #7 VIA A 20A/1 P CIRCUIT BREAKER WITH NN 2#12AWG, #12(G), 3/4"CONDUIT UNLESS NOTED OTHERWISE. HASH MARKS INDICATE S❑X CONDUCTOR QUANITY AND TYPES. - - - - - UNDER FLOOR OR IN -SLAB CIRCUITING OR RACEWAY 0 CIRCUITRY TURNING UP POWER DISTRIBUTION EQUIPMENT SYMBOL LEGEND SYMBOL DESCRIPTION G 48OV277 VOLT, 30, 4 WIRE BRANCH CIRCUIT PANELBOARD 208Y/120 VOLT, 30, 4 WIRE BRANCH CIRCUIT PANELBOARD FIRM ALARM SYMBOL LEGEND ❑F MANUAL PULL STATION E4 COMBINATION AUDIBLE/VISUAL (HORN/STROBE) SIGNALING DEVICE Q VISUAL (STROBE) ONLY SIGNALING DEVICE S❑X SMOKE DETECTOR - "X" INDICATES THE FOLLOWING: "E" DENOTES SMOKE DETECTOR WITH AUXILIARY CONTACTS FOR ELEVATOR RECALL. DEMOLITION ANNOTATION LEGEND "X" DENOTES EXISTING DEVICE/EQUIPMENT TO BE REMOVED IN ITS ENTIRETY INCLUDING JUNCTION M E B BOXES, CONDUITS AND CIRCUITRY, ETC. COMPLETE, BACK TO SOURCE OR NEXT ACTIVE DEVICE L Y BEING MAINTAINED ON CIRCUIT. "XR" DENOTES EXISTING DEVICE/EQUIPMENT TO BE RELOCATED IN ITS ENTIRETY. MAINTAIN ALL BRANCH CIRCUIT WIRING, CONDUIT, ETC. FOR RELOCATION TO NEW LOCATION ("XN") AS IS= INDICATED ON "NEW WORK" DRAWINGS. "XN" DENOTES NEW LOCATION OF EXISTING RELOCATED ("XR") DEVICE/EQUIPMENT. REWORK ALL BRANCH CIRCUIT WIRING, CONDUIT, ETC. TO NEW LOCATION AS REQUIRED. "XM" DENOTES EXISTING DEVICE/EQUIPMENT TO BE MAINTAINED. • � Integrated l� Engineering Consultants, Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 (P): 216.901.6711 (F): 216.901.6712 www.iec-inc.cc ,,,, I1111/1,,,,, S TTFR No. 11400468 = •� '• =-o'STATE OF GENERAL ELECTRICAL NOTES 1. ALL "BUILDING STANDARDS" AND/OR "BUILDING SPECIFICATIONS" SHALL BE CONSIDERED AN INTEGRAL PART OF THESE DOCUMENTS AND THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN A COPY OF THESE DOCUMENTS AND COMPLY WITH ALL REQUIREMENTS, STANDARDS, AND SPECIFICATIONS CONTAINED WITHIN. 2. THESE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ARE INTENDED TO CONVEY THE SCOPE OF WORK AND INDICATE GENERAL ARRANGEMENT OF LIGHTING FIXTURES, DEVICES, CONTROLS, ELECTRICAL FIXTURES, MOTORS, PANELBOARDS, EQUIPMENT, ETC. THE LOCATIONS OF ALL ITEMS SHOWN ON THESE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED AT THE PROJECT. ALL LOCATIONS OF WORK EXPOSED TO VIEW ARE SUBJECT TO APPROVAL OF THE ARCHITECT PRIOR TO ROUGH -INS. 3. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT ALL NEW WORK WILL FIT INTO THE EXISTING STRUCTURE AND CONDITIONS IN THE MANNER INTENDED AND AS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/OWNERS REPRESENTATIVE PRIOR TO ANY ROUGH -INS, FABRICATIONS, OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A RFI, INCLUDING A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. 4. ANY DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE PROMPTLY BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION DURING THE BIDDING PERIOD. NO ALLOWANCE SHALL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF HIS FAILURE TO HAVE BROUGHT SAID DISCREPANCIES TO THE ATTENTION OF THE ENGINEER DURING THE BIDDING PERIOD OR OF ANY ERROR ON THE CONTRACTOR'S PART. 5. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT, PROFESSIONAL AND WORKMANLIKE MANNER, RECTILINEAR TO FINISHES AND BUILDING STRUCTURE. 6. ALL COMPONENTS SHOWN ON THE RISER/ONE-LINE DIAGRAMS, BUT NOT ON THE PLAN OR VICE VERSA, SHALL BE INCLUDED AS IF SHOWN ON BOTH. 7. REFER TO ARCHITECTURAL ELEVATIONS TO DERIVE EXACT LOCATIONS OF ALL RECEPTACLES, OUTLETS/JACKS, SWITCHES, WALL AND PENDANT/CABLE MOUNTED LUMINAIRES, ETC. LUMINAIRES AND CEILING MOUNTED EQUIPMENT SHALL BE COORDINATED WITH THE ARCHITECTURAL RCP (REFLECTED CEILING PLANS). 8. ALL CIRCUITING SHALL BE RUN CONCEALED UNLESS SPECIFIED OTHERWISE. 9. ALL RACEWAYS RUNNING THROUGH BUILDING EXPANSION JOINTS SHALL BE EQUIPPED WITH APPROPRIATE EXPANSION FITTINGS. 10. CONDUIT HOME RUNS SHOWN ON THE DRAWING WITH MORE THAN (3) CURRENT CARRYING CONDUCTORS ARE SHOWN DIAGRAMATICALLY. THIS CONTRACTOR SHALL NOT INSTALL MORE THAN (3) CURRENT CARRYING CONDUCTORS IN A RACEWAY UNLESS NATIONAL ELECTRIC CODE (N.E.C), ARTICLE 310.15 DERATING FACTORS ARE APPLIED. 11. ALL LIGHTING AND GENERAL POWER BRANCH CIRCUITS SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR, UNLESS SPECIFICALLY INDICATED OTHERWISE. 12. THE ELECTRICAL CONTRACTOR SHALL REFER TO THE ELECTRICAL SPECIFICATIONS FOR ACCEPTABLE CONDUIT TYPES/LOCATIONS. ALL CONDUIT SIZES ON THE DRAWINGS ARE BASED ON THE CURRENT ADOPTED EDITION OF THE N.E.C. CONDUIT FILL TABLES FOR ELECTRICAL METALLIC TUBING E.M.T . CONDUIT SIZES SHALL BE REVISED TO THE SIZE REQUIRED, RELATIVE TO THE ACTUAL CONDUIT TYPE TO BE INSTALLED. 13. IT IS NOT INTENDED THAT THE PLANS INDICATE ALL OBSTRUCTIONS, NECESSARY BENDS, OFFSETS, AND PULL BOXES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL HIS WORK TO CONFORM TO N.E.C. REQUIREMENTS, THE STRUCTURE, MAINTAIN HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR. REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS AS REQUIRED. 14. IT IS NOT INTENDED THAT THE PLANS INDICATE ALL CONDUIT ROUTES, PULL BOXES, JUNCTION BOXES, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING ACTUAL CONDUIT ROUTING, QUANTITY AND LOCATION OF PULL BOXES WITHIN ACCESSIBLE LOCATIONS. 15. PROVIDE SCREW -COVER PULL BOXES IN CONDUIT RUNS AS REQUIRED TO LIMIT THE NUMBER OF BENDS TO NO MORE THAN FOUR (4) 90° OR 360 DEGREES TOTAL. SIZE PULL BOXES IN ACCORDANCE WITH NEC, ARTICLE 314.28, DOCUMENT ON RECORD DRAWINGS, SIZE AND LOCATION OF PULL BOXES USED IN FEEDER CONDUIT RUNS. 16. WHERE MULTIPLE DEVICES OF THE SAME TYPE/STYLE ARE SHOWN NEXT TO EACH OTHER, GANG TOGETHER IN A SINGLE COVER PLATE. 17. ALL FLUSH MOUNTED PANELBOARDS SHALL HAVE THREE (3), 3/4" CONDUITS STUBBED ABOVE ACCESSABLE CEILINGS FOR FUTURE CIRCUITS. 18. FIELD VERIFY THE EXACT LOCATION OF MECHANICAL HVAC AND PLUMBING EQUIPMENT THAT REQUIRE ELECTRICAL CONNECTIONS WITH RESPECTIVE CONTRACTORS. a TYPICAL DEVICE MOUNTING FIRE ALARM AUDIBLE/VISUAL AND VISUAL ONLY SIGNALING DEVICES RECEPTACLES BEHIND 0 REFRIGERATORS AND ® VENDING MACHINES WALL TELEPHONES FIRE ALARM MANUAL PULL STATION LIGHTING CONTROLS (CONFIRM MOUNTING HEIGHT a WITH LOCAL CODE REQUIREMENTS) VOLUME CONTROLS M: DEVICES ABOVE COUNTERTOP AND/OR BACKSPLASH aa a M RECEPTACLES IN MECH/ELEC SPACES AND ADJACENT TO LAVATORIES o o ® a M: RECEPTACLES BEHIND �a DOMESTIC WASHERS AND DRYERS GENERAL PURPOSE 00 RECEPTACLES VOICE/DATA OUTLETS ap 6] O RECEPTACLES SERVING DISHWASHER AND °O GARBAGE DISPOSAL I FINISHED FLOOR a NOTES: 1. ALL MOUNTING HEIGHTS SHALL BE MEASURED FROM FINISHED FLOOR TO THE CENTERLINE OF DEVICE EXCEPT FIRE ALARM STROBE LIGHT. 2. NO WIRING DEVICE OUTLET BOXES SHALL BE MOUNTED BACK TO BACK. 3. ALL MOUNTING DEVICES SHALL BE INSTALLED AT MOUNTING HEIGHTS AS INDICATED ON THIS DETAIL UNLESS OTHERWISE NOTED. 4. FOR ALL ELEVATIONS (WHERE APPLICABLE), CASEWORK DETAILS, FIRE WALLS, SMOKE WALLS, LOCATION OF COUNTERTOP RECEPTACLES, LIGHTING FIXTURE SWITCHES, TELEPHONE OUTLETS, EQUIPMENT ROUGH -INS, HEADWALLS, ETC., SEE ARCHITECTURAL DRAWINGS. WHERE NO ARCHITECTURAL ELEVATIONS OR DETAILS OCCUR, THE ELECTRICAL CONTRACTOR SHALL USE PRACTICAL MEANS AND METHODS AS WELL AS HIS FIELD KNOWLEDGE TO LOCATE DEVICES IN THE BEST SUITED AND MOST PRACTICAL LOCATIONS FOR THE DEVICE. H E M E B L L Y E R LEW Client Approval: IS= ARCH ITECTU RE INTERIOR DESIGN 2 1 1 South 12th St. Phila., PA 1 9107 21 5.922.7066 THE GENERAL CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAL SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMBING WORK WITH THE ARCHITECTURAL WORK AND OF ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. Project: Liberty Mutual. INSURANCE 450 East 96th St 4th Floor Indianapolis IN 46240 Project No: 047.41 Drawing: Electrical Schedules, Legends and Notes No. E-0.04 Drawn by: M E B Checked by: A,JM Approved by: A,JM Client Approval: Date: Issue Date: 01 /26/18 Issue For Permit: 01 /29/18 No. Date Revision Scale: Drawing: Electrical Schedules, Legends and Notes No. E-0.04