Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
04060015 Building Plans
Janitor Joint Kitchen Laboratory Laminate Lavatory Locker Light Maximum Medicine Cabinet Mechanical Membrane Metal Manufacturer Manhole Minimum Mirror Miscellaneous Masonry Opening Mounted Mullion New Not in Contract Number Nominal Not to Scale Overall Obscure On Center Outside Diameter (Dim.) Office Opening Opposite Precast Plate Plastic Laminate Plaster Plywood Pair Point Paper Towel Dispenser Combination Paper Towel Dispenser & Receptacle Quarry Tile Relocate Rodius Roof Drain Reference Refrigerator Register Reinforced Required Resilient Room Rough Opening Redwood Rain Water Leader South Solid Core Seat Cover Dispenser Schedule Soap Dispenser Section Shelf Shower Sheet Similar Sanitary Napkin Dispense Sanitary Napkin Receptacle Sealant Specification Square Stainless Steel Service Sink Station Standard Steel Storage Structural Suspended Symmetrical Tread Towel Bar Top of Curb Telephone Terrazzo Tongue and Groove Thick Top of Pavement Toilet Paper Dispenser Television Top of Wall Typical Unfinished Unless Otherwise Noted Urinal Vinyl Composition Tile Vertical Vestibule Verify in Field West With Water Closet Wood Without Waterproof Wainscot Weight GENERAL NOTES 1. ABBREVIATIONS GENERAL INFORMATION & And JAN. MENTIONED OR SHOWN. UNLESS EXPRESSLY STATED, ALL SYSTEMS AND EQUIPMENT L Angle JT. REFLECTED CEILING PLAN At SPECIFIED AND APPROPRIATE ITEMS, AND ALL INCIDENTAL, ACCESSORY, AND 04A-5.0 CL Centerline KIT. PANEL PLAN 0 Diameter 2. NO WORK DEFECTIVE IN WORKMANSHIP OR QUALITY OR DEFICIENT IN ANY 1 Perpendicular LAB. IOR C Channel LAM. DURING CONSTRUCTION. DEFECTIVE WORK REVEALED WITHIN THE TIME REQUIRED BY # Pound or Number LAV. C H I C A G O (E) Existing LK R. ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS. 3. LT. ACOUS, Acoustical PENETRATIONS GENERATED BY THE WORK DESCRIBED IN THESE DOCUMENTS. A. D. Area Drain MAX. ADJ. Adjustable M. C. IN CONTRASTING INK ON THE DRAWINGS FOR ALL RUNS OF MECHANICAL, SPRINKLER, A.F.F. Above Finish Floor MECH AGGR. Aggregate MEMB WILL PROVIDE THE CONTRACTOR W/ A REPRODUCIBLE SET OF ORIGINAL DOCUMENTS FOR AL. Aluminum MTL. APPROX. Approximate MFR. IT IS INTENDED THAT THE CONTRACTOR PROVIDE A COMPLETE JOB AND ANY ARCH. Architectur I MH. ASB. Asbestos MIN. BY SCOPE OF WORK EXCEPT FOR ITEMS SPECIFICALLY NOTED. ASPH. Asphalt MIR. REASONS, UNENFORCEABLE, SUCH UNENFORCEABILITY SHALL NOT EXTEND TO THE MISC. REMAINDER OF THE CONTRACT NOR SHALL IT VOID ANY OTHER PROVISIONS OF THE BD. Board M.O. 7. BITUM. Bituminous MTD. COULD LEAD TO THE FILING OF CLAIMS OF LIEN BY SUBCONTRACTORS, BLDG. Building MUL. BILK. Block REGULATIONS UNLESS REASONABLE AND JUSTIFIABLE CAUSE CAN BE SHOWN. BLKG. Blocking APPROVAL FOR PAYMENT SHALL BE CONTINGENT UPON THE CONTRACTOR'S BM. Beam N. INDIVIDUALS OR COMPANIES. BOT. Bottom N.I.C. B.T.B. BACK TO BACK NO. c BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY NOM. CAB. Cabinet N.T.S. FOR OBTAINING A WRITTEN CLARIFICATION FROM THE ARCHITECT BEFORE C.B. Catch Basin PROCEEDING WITH WORK IN QUESTION, OR RELATED WORK. 9. CEM. Cement O.A. FEDERAL CODES, MANUFACTURER'S RECOMMENDATIONS, TRADE AND REFERENCE CER. Ceramic OBS. C. 1. Cast Iron O.C. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN CLG. Ceiling O.D. CLO. Closet OFF. CLARIFY ALL DISCREPENCIES RELATIVE TO CONSTRUCTION DOCUMENTS, SPECIFICATIONS, CLR. Clear OPNG 12. COL. Column OPP • CONIC. Concrete PRCSI CONSTR. Construction PL. j 13. CONT. Continuous P. LAM CORR. Corridor PLAS. •• CTSK. Countersunk PLYW[ CNTR. Counter PR, ALL INSTALLED PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL CTR. Center PT. • DBL. Double P.T.D. DEPT. Departmen P.T.D/ D. F. Drinking Fountain AND/OR INCOMPLETE WORK. FINAL PAYMENT WILL BE CONTINGENT UPON THE COMPLETION D ET. Detail Q.T. 17. DIA. Diameter RESPECT UNLESS OTHERWISE NOTED. MANUFACTURED MATERIALS AND EQUIPMENT DIM. Dimension R • DISP. Dispenser RAD. THE CONTRACTOR AND SUBCONTRACTORS SHALL PURCHASE AND MAINTAIN DN. Down R.D. D.O. Door Opening REF. .. DR. Door REFR. 19. DWR. Drawer RGTR. CAUSE DAMAGE TO ANY TENANT IN THE BUILDING. AVOID CONFLICT' DS. Downspout REINF D.S.P. Dry Stand ipe REQ'D DOCKS FOR DELIVERIES, HANDLING OF MATERIALS, EQUIPMENT, AND DEBRIS. DWG. Drawings RESIL. 20. VERIFY IN THE FIELD, THAT NO CONFLICTS EXIST WHICH PROHIBIT THE LOCATION RM. OF ANY AND ALL MECHANICAL, TELEPHONE, ELECTRICAL, PLUMBING AND SPRINKLER E Existing R.O. EA. Each RWD. PROVIDE PROTECTION TO ALL EXISTING FINISHES IN ALL SPACES WITHIN OR ADJACENT E.J. Expansion Joint R.W.L. t EL. Elevation ' MATCH EXISTING ADJACENT FINISH, OR AS NOTED HEREIN. ELEC. Electrical S. ELEV. Elevator S.C. UNEVEN SURFACES AND FINISHES AT GYPSUM BOARD OR DAMAGED FIREPROOFING. EMER. Emergency S.C.D. PATCH AND REPAIR SURFACES TO MATCH ADJACENT, ADJOINING SURFACES. ENCL. Enclosure SCHE[ 23. E. P. Electrical Panel S. D. EQ. Equal SECT. EQPT. Equipment SH. "SIMILAR" OR "SIM." MEANS COMPARABLE CHARACTERS -!CS TO THE CONDITION E.W.C. Electric H2D Cooler SHR. (E) Existing SHT. EXIST. Existing SIM. EXPO. Exposed S.N.D. ARCHITECT. EXP. Expansion S.N.R. EXT. Exterior SNT. 26. SPEC. F.A. Fire Alarm SQ. U.O.N.. F.B. Flat Bar S.S. 27. F. D. Floor Drain S.SK. FDN. Foundation STA. PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS F. E. Fire Exting jisher STD. F.E.C. Fire Exting Jsher Cab STL. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING OF ACCES; INTO ADJACENT F.H.C. Fire Hose abinet STOR. FIN. Finish STRL. FL. Floor SUSP. FLASH. Flashing SYM. • FLUOR, Fluorescent ANY WILL BE AS BINDING AS IF CALLED FOR BY ALL. ALL WORK SHOWN OR ,1 F.O.C. Face of Cc ncrete TRD. :s F.O.F. Face of Finish T. B. ,. F.O.S. Face of St ds T. C. FPRF. Fireproof TEL. d` F. S. Full Size TER. FT. Foot or Feet T.&G. F.T. Fire Treated THK. FTG. Footing T. P. FURR. Furring T.P.D. F&I Furnish anc Install T.V. FUT. Future T.W. TYP. GA. Gauge THE ARCHITECT HAS NO KNOWLEDGE OF AND SHAD NOT BE ',IABLE FOR ANY ' GALV. Galvanized UNF. c . G.B. Grab Bar U.O.N. G.C. General Co tractor UR. r GL. Glass/glazir g GND. Ground V.C.T. GR. Grade VERT. GYP. Gypsum VEST. V.I.F. IL H.B. Home Bid H.C. Hollow Cab W. HDWD. Hardwood W/ HDWE. Hardware W.C. H.M. Hollow Metal WD. HORIZ. Horizontal W/0 HR. Hour WP. HGT. Height WSCT. WT. 1. D. Inside Diam ter (Dim.) INSUL. Insulation INT. Interior Janitor Joint Kitchen Laboratory Laminate Lavatory Locker Light Maximum Medicine Cabinet Mechanical Membrane Metal Manufacturer Manhole Minimum Mirror Miscellaneous Masonry Opening Mounted Mullion New Not in Contract Number Nominal Not to Scale Overall Obscure On Center Outside Diameter (Dim.) Office Opening Opposite Precast Plate Plastic Laminate Plaster Plywood Pair Point Paper Towel Dispenser Combination Paper Towel Dispenser & Receptacle Quarry Tile Relocate Rodius Roof Drain Reference Refrigerator Register Reinforced Required Resilient Room Rough Opening Redwood Rain Water Leader South Solid Core Seat Cover Dispenser Schedule Soap Dispenser Section Shelf Shower Sheet Similar Sanitary Napkin Dispense Sanitary Napkin Receptacle Sealant Specification Square Stainless Steel Service Sink Station Standard Steel Storage Structural Suspended Symmetrical Tread Towel Bar Top of Curb Telephone Terrazzo Tongue and Groove Thick Top of Pavement Toilet Paper Dispenser Television Top of Wall Typical Unfinished Unless Otherwise Noted Urinal Vinyl Composition Tile Vertical Vestibule Verify in Field West With Water Closet Wood Without Waterproof Wainscot Weight GENERAL NOTES 1. THE INTENT OF THE CONTRACT DOCUMENTS IS TO ALLOW FOR TELE PERFORMANCE OF GENERAL INFORMATION THE WORK. EVERY ITEM NECESSARILY REQUIRED MAY NOT BE SPECIFICALLY PARTITION PLAN MENTIONED OR SHOWN. UNLESS EXPRESSLY STATED, ALL SYSTEMS AND EQUIPMENT POWER & SIGNAL PLAN SHALL BE COMPLETED AND APPROPRIATELY OPERABLE. FURNISH AND INSTALL ALL REFLECTED CEILING PLAN 04A-4.0 SPECIFIED AND APPROPRIATE ITEMS, AND ALL INCIDENTAL, ACCESSORY, AND 04A-5.0 FURNITURE PLAN OTHER ITEMS NOT SPECIFIED BUT REQUIRED FOR A COMPLETE AND FINISHED PANEL PLAN ASSEMBLY. 2. NO WORK DEFECTIVE IN WORKMANSHIP OR QUALITY OR DEFICIENT IN ANY E REQUIREMENTS OF THE CONTRACT DOCUMENTS WILL BE ACCEPTABLE DESPITE THE IOR ARCHITECT'S FAILURE TO DISCOVER OR POINT OUT DEFECTS OR DEFICIENCIES ARCHITECTS DURING CONSTRUCTION. DEFECTIVE WORK REVEALED WITHIN THE TIME REQUIRED BY GUARANTEES SHALL BE REPLACED BY WORK CONFORMING WITH THE INTENT OF THE C H I C A G O CONTRACT. NO PAYMENT, EITHER PARTIAL OR FINAL, SHALL BE CONSTRUED AS AN ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS. 3. PATCH AND REPAIR ALL FIREPROOFING DAMAGE INCURRED DURING DEMOLITION AND/OR CONSTRUCTION. FIREPROOF AS REQUIRED BY CODE ALL NEW PENETRATIONS GENERATED BY THE WORK DESCRIBED IN THESE DOCUMENTS. 4. DURING THE COURSE OF CONSTRUCTION, ACTUAL LOCATIONS OF CONSTRUCTION ITEMS DENOTED IN THE CONSTRUCTION DOCUMENTS SHALL BE INDICATED TO SCALE, IN CONTRASTING INK ON THE DRAWINGS FOR ALL RUNS OF MECHANICAL, SPRINKLER, PLUMBING AND ELECTRICAL WORK; INCLUDING SITE UTILITIES AND CONCEALED DEVIATIONS FROM THE DRAWINGS. UPON` COMPLETION OF THE PROJECT THE ARCHITECT WILL PROVIDE THE CONTRACTOR W/ A REPRODUCIBLE SET OF ORIGINAL DOCUMENTS FOR "AS -BUILT" DOCUMENTATION. THIS SET SHALL BE CONSPICUOUSLY MARKED "AS-BUILTS" AND DELIVERED TO THE ARCHITECT. 5. IT IS INTENDED THAT THE CONTRACTOR PROVIDE A COMPLETE JOB AND ANY OMISSIONS IN THESE NOTES OR IN THE OUTLINE OF WORK SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR OF SUCH RESPONSIBILITIES IMPLIED BY SCOPE OF WORK EXCEPT FOR ITEMS SPECIFICALLY NOTED. 6. SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE, FOR WHATEVER REASONS, UNENFORCEABLE, SUCH UNENFORCEABILITY SHALL NOT EXTEND TO THE REMAINDER OF THE CONTRACT NOR SHALL IT VOID ANY OTHER PROVISIONS OF THE CONTRACT. 7. THROUGHOUT THE DURATION OF THE PROJECT REFRAIN FROM ACTIONS THAT COULD LEAD TO THE FILING OF CLAIMS OF LIEN BY SUBCONTRACTORS, SUPPLIERS OF MATERIALS, LABOR, SERVICE, EQUIPMENT OR ANY OTHER INDIVIDUAL OR COMPANY SO ENTITLED UNDER GOVERNING LAWS AND REGULATIONS UNLESS REASONABLE AND JUSTIFIABLE CAUSE CAN BE SHOWN. APPROVAL FOR PAYMENT SHALL BE CONTINGENT UPON THE CONTRACTOR'S OBTAINING AND FURNISHING TO THE ARCHITECT SIGNED RELEASES FROM SUCH INDIVIDUALS OR COMPANIES. 8. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION ISSUES, THE CONTRACTOR SHALL SUBMIT THEM, IN WRITING, TO THE ARCHITECT AND IS RESPONSIBLE FOR OBTAINING A WRITTEN CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION, OR RELATED WORK. 9. EXECUTE WORK IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, FEDERAL CODES, MANUFACTURER'S RECOMMENDATIONS, TRADE AND REFERENCE STANDARDS INCLUDING BUT NOT LIMITED TO: UBC, SEISMIC CODES, NEC, NEPA, ASIC, UMC, LATEST ENFORCED EDITIONS. 10. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. WRITTEN SPECIFICATIONS SHALL GOVERN OVER ALL. 11. CLARIFY ALL DISCREPENCIES RELATIVE TO CONSTRUCTION DOCUMENTS, SPECIFICATIONS, AND FIELD CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. 12. THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR EQUAL" IS USED, THE ARCICT ALONE SHALL DETERMINE EQUALITY BASED UPON INFORMATION SUBMITTED BY THE CONTRACTOR. j 13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER HIS JURISDICTION. 14. DO NOT PROCEED WITH ANY WORK REQUIRING ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER. FAILURE TO OBTAIN AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION. 15. ALL INSTALLED PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL OPERATE QUIETLY AND FREE OF VIBRATION. 16, UPON NOTIFICATION OF COMPLETION OF THE WORK AND DELIVERY OF THE CONTRACTOR'S PUNCHLIST, THE ARCHITECT SHALL PREPARE A PUNCH -LIST OF CORRECTIONS, UNSATISFACTORY AND/OR INCOMPLETE WORK. FINAL PAYMENT WILL BE CONTINGENT UPON THE COMPLETION OF THESE ITEMS UNDER THE TERMS OF THE OWNER/CONTRACTOR AGREEMENT. 17. ALL MATERIALS SHALL BE NEW, UNUSED, AND OF THE HIGHEST QUALITY IN EVERY RESPECT UNLESS OTHERWISE NOTED. MANUFACTURED MATERIALS AND EQUIPMENT SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS, U.O.N. 18. THE CONTRACTOR AND SUBCONTRACTORS SHALL PURCHASE AND MAINTAIN CERTIFICATIONS OF INSURANCE WITH RESPECT TO WORKERS COMPA+ISATION, PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE LIMITS AS REQUIRED BY LAW. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK 19. COORDINATE ALL WORK WITH BUILDING OWNER SO AS NOT TO D{ B OR CAUSE DAMAGE TO ANY TENANT IN THE BUILDING. AVOID CONFLICT' INTERFERENCE WITH NORMAL BUILDING OPERATIONS BY COMPLY! WITH THE BUILDING'S REGULATIONS REGARDING SCHEDULING AND USE OF ELEVATORS AND LOADING DOCKS FOR DELIVERIES, HANDLING OF MATERIALS, EQUIPMENT, AND DEBRIS. �I 20. VERIFY IN THE FIELD, THAT NO CONFLICTS EXIST WHICH PROHIBIT THE LOCATION OF ANY AND ALL MECHANICAL, TELEPHONE, ELECTRICAL, PLUMBING AND SPRINKLER EQUIPMENT (TO INCLUDE ALL REQUIRED PIPING, DUCTWORK AND CONDUIT) AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ABOVE EQUIPMENT ARE PROVIDED. 21. PROVIDE PROTECTION TO ALL EXISTING FINISHES IN ALL SPACES WITHIN OR ADJACENT TO THE SCOPE OF WORK AND THE TENANT'S SPACE. THE CONTRACTOR SHALL PATCH t AND REPAIR ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS. REFINISH TO ' MATCH EXISTING ADJACENT FINISH, OR AS NOTED HEREIN. 22. CORRECT ANY DEFECTS FOUND IN EXISTING BUILDING CONSTRUCTION WHICH AFFECT THE SCOPE OF WORK. THIS INCLUDES BUS S NOT LIMITED TO UNEVEN SURFACES AND FINISHES AT GYPSUM BOARD OR DAMAGED FIREPROOFING. PATCH AND REPAIR SURFACES TO MATCH ADJACENT, ADJOINING SURFACES. $ 23. "TYPICAL" OR "TYP." MEANS IDENTICAL FOR ALL S V _AR CONDITIONS U.O.N. 24. "SIMILAR" OR "SIM." MEANS COMPARABLE CHARACTERS -!CS TO THE CONDITION NOTED. VERIFY DIMENSIONS AND ORIENTATION ON P'_ '.. 25. 'VERIFY" OR 'VER." MEANS TO ASCERTAIN AND C'-'.-- ='.' APPLICATION WITH HIM ARCHITECT. 26. FURNITURE SHOWN IS FOR REFERENCE ONLY AND INSTALLED BY OTHERS U.O.N.. { 27. FILE CABINETS, AS SHOWN ON DRAWINGS, ARE SUPPLIED BY OTHERS. COORDINATE FILE SIZES) W/ FURNITURE INSTALLER FOR REQ'D CLEARANCES. i 28. PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS FROM EMANATING FROM CONSTRUCTION AREA. 29. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING OF ACCES; INTO ADJACENT TENANT SPACES WITH THE BUILDING MANAGEMENT AS REQUIRE-' FOR PRICING. 30. { CONTRACTOR SHALL THOROUGHLY EXAMINE THE PREMISES AN- S -ALL BASE HIS BID ON THE EXISTING CONDITIONS, NOTWITHSTANDING ANY INFORMA- L', SHOWN OR NOT 33. INDICATED ON THE CONTRACT DOCUMENTS. ALL CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS CALLED FOR BY ANY WILL BE AS BINDING AS IF CALLED FOR BY ALL. ALL WORK SHOWN OR ,1 REFERRED TO ON ANY CONTRACT DOCUMENT SHALLBE PROVIDED AS THOUGH THEY :s ARE ON ALL RELATED DOCUMENTS. �r 32. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE d` ARCHITECT OF ANY CONFLICTS HEREIN -EITHER APPARENT OR OBVIOUS -PRIOR TO THE START OF NEW WORK ON THAT ITEM OR BEAR "E RESPONSIBILITY OF CORRECTING SUCH WORK AS DIRECTED BY THE ARCri'ECT. 33. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE OPIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. 34. THE ARCHITECT HAS NO KNOWLEDGE OF AND SHAD NOT BE ',IABLE FOR ANY ' ASBESTOS OR OTHER HAZARDOUS MATERIALS ON T>~E jOB SITE. ASBESTOS OR c . OTHER HAZARDOUS MATERIALS ARE DISCOVERED DURING CONS`R„C-ON, OR DEMOLITION, STOP WORK AND CONTACT OWNER FOR FURTHER, INSTRUCTIONS SEF RE PROCEEDING. r IL I INTERNATIONAL BUILDING CODE 2000 ACKNOWLEDGEMENT, CODE SUMMARY AND NOTES BUILDING ADDRESS: 1611 N. MERIDIAN ST. CARMEL, IN 46032 4TH FLOOR OCCUPANCY GROUP: BUSINESS GROUP B (SECTION 304) OCCUPANCY CONTENT: 100 SQ FT PER OCCUPANT GROSS (TABLE 1003.2.2.2) BUILDING TYPE: TYPE -1B (TABLE 601) THIS IS A FULLY SPRINKLERED BUILDING CORRIDOR WALLS: 0 HOUR (TABLE 1004.3.2.1) WALL SEPARATION BETWEEN TENANTS: 1 HOUR (TABLE 302.3.3) MAXIMUM TRAVEL DISTANCE TO AN EXIT: 300 FEET (W/ SPRINKLER SYSTEM) (TABLE 1004.2.4) MAXIMUM TRAVEL DISTANCE FROM 50 FEET (W/ SPRINKLER SYSTEM) END OF A CORRIDOR: (SECTION 1004.3.2.3) PROJECT AREA: 3,400 SF CALCULATED OCCUPANT LOAD: 34 PERSONS 1. THIS PROJECT IS TO COMPLY WITH, AND HAS BEEN DESIGNED IN ACCORDAN�` WITH THE FOLLOWING GOVERNING AUTHORITIES:v A. INTERNATIONAL BUILDING CODE 2000 B. BUILDING OWNER'S REQUIREMENTS 2. NO CHANGE IN OCCUPANCY CLASSIFICATION OR CONSTRUCTION TYPE. 3. EXECUTE ALL WORK IN ACCORDANCE WITH LOCAL AND FEDERAL CODES, MANUFACTURERS RECOMMENDATIONS, TRADE -AND REFERENCE STANDARDS. 4. ALL EXISTING CONDITIONS INDICATED ARE AS FOUND IN THE FIELD SURVEY OF THE PREMISES BY THE ARCHITECT. EXISTING CONDITIONS NOT IN COMPLIANCE WITH THOSE SHOWN ARE THE RESPONSIBILITY OF THE BUILDING OWNER. 5. THE SPACE AROUND DUCTS, PIPES, ELECTRICAL CONDUITS, CABLE TRAYS, AND ALL OTHER ELECTRICAL/MECHANICAL WORK PENETRATING RATED WALLS OR BETWEEN FLOORS SHALL NOT EXCEED 1/2" AND SHALL BE PACKED SOLID WITH MINERAL WOOL OR AN APPROVED EQUAL MATERIAL AND BE CLOSED OFF BY CLOSE -FITTING ESCUTCHEONS ON BOTH SIDES OF THE PENETRATION. 6. THE CONTRACTOR SHALL REPLACE ALL MISSING FIREPROOFING & FIRESTOPPING. THE CONTRACTOR SHALL REPLACE ALL FIREPROOFING AFFECTED BY NEW CONSTRUCTION WITH FIREPROOFING TO MATCH BASE 91JILDING STANDARDS, APPROVED EQUAL, OR AS REQUIRED TO MATCH THE EXISTING, 7. ALL EXIT SIGNS SHALL COMPLY WITH SECTION 1003.2.10 OF THE INTERNATIONAL BUILDING CODE 2000. 8. ALL CONSTRUCTION TO BE NON-COMBUSTIBLE. 9. ALL WOOD,*Q WOOD BLOCKING SHALL BE FIRE RETARDANT AS PER SECTION 2303 OF THE INTERNATIONAL BUILDING CODE 2000. 10. ALL INTERIOR FINISHES SHALL COMPLY WITH CHAPTER 8 - INTERIOR FINISHES OF THE INTERNATIONAL BUILDING CODE 2000 FOR FLAMMABILITY & SMOKE DEVELOPED RATINGS AND TOXICITY. 11, ALL DOORS TO BE 36" WIDE CLEAR, 34" MIN. (U.O.N.) 12. ALL AREAS ARE MECHANICALLY VENTILATED. 13. THE CONTRACTOR SHALL PROTECT THE PUBLIC AND TENANT FROM ALL WORK IN PROGRESS. SITE PLAN PROJECT DIRECTORY ARCHITECT CONTRACTOR IA CHICAGO, PC REI CONSTRUCTION SERVICES 205 WEST WACKER, SUITE 1500 11711 NORTH PENNSYLVANIA STREET, SUITE 200 CHICAGO, IL 60606 CARMEL, IN 46032-4559 PROJECT MANAGER: KARA YOUNG PROJECT MANAGER: DIANE ENGLISH �312� 553-8200 553-8208 FAX 317 573-6816 �317� 573-6857 FAX CLIENT LIBERTY MUTUAL GROUP 175 BERKELEY STREET BOSTON, MA 02117 DESIGN PROJECT MANAGER: JEAN HABECK �7842-6711 15� 843-3658 FAX BUILDING MANAGER ZELLER MANAGEMAENT CORP. 11595 N. MERIDIAN STREET SUITE 320 CARMEL, IN 46032 CONTACT: JESSICA MEEK (317) 580-2430 PHONE (317) 580-2429 FAX INDEX OF DRAWINGS ARCHITECTURAL AN.1 GENERAL INFORMATION 04A-1.0 PARTITION PLAN 04A-2.0 POWER & SIGNAL PLAN 04A-3.0 REFLECTED CEILING PLAN 04A-4.0 FINISH PLAN 04A-5.0 FURNITURE PLAN 04A-5.1 PANEL PLAN A8.1 DETAILS SYMBOLS y �cny a x �D COLUMN GRID LINE ., l oo o Y N =. r c Oy x 0 _ y fl.. y fD .q rD[�7 M z own OFFICE _ ry ID y - 300 ROOM NAME & NUMBER ° a y n - 0 C) DETIL a DETAIL REFERENCE 3 E =• �7 HE = B r 7 to 12 r-, oilrD �n 3 9rD -�� �� � n na REVISION KEY a ow CJ M�"� `D Ij meD•c > A DOOR MARK B w A HARDWARE TYPE N o ' � o z �^ x s < A ® KEYED SHEET NOTE n D ZT, In pIt INTERIOR ELEVATION A7 DETAIL / SHEET r y KEY PLAN Lib rty., Mutu 10 INDIANAPOLIS LEGAL 11611 N. MERIDIAN ST. CARMEL, IN 46032 4TH FLOOR sl�kUG�`OVsstov\9 lt Vow 1 apOgy oi �lC�' rr0,\ �'�E'�? SO? to cra\-0 S100� oiof00. 3 ISSUE FOR CONSTRUCTION DESIGN RELEASE 05/17/04 2 (ISSUE FOR PRICING 04/19/04 1 ISSUE FOR CLIENT REVIEW 04/05/04 Issue Description Date 1AINT E R IOR ARCHITECTS C H I C A G O IA CHICAGO, P.C. 205 WEST WACKER, SUITE 1500 CHICAGO, ILLINOIS 60606 312-553-8200 FAX 312.553.8208 0 2004 IA, Inc. ALL DRAWINGS WRITTEN MATERIAL HEREIN CONSTTUiE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT:1N1 AND THE SAME MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OFT ARCHITECT. Drawn: ESM Check: KSY Owner Approval: ,Job No: O. 4110.00 Scale: 1/8'=1'-0' GENERAL NOTES AND Title: ABBREVIATIONS Sheet: ■ 0 O CONFERENCE 425 13'-3 10,4, OPEN C OFFICE-, A OFFICE OFFICE AREA 423 428R] 429 A A 5-0" 5 o OPEN OFFICE AREA � 427 2 C A 5 �g 0 1 FILE AREA 1 �� 420 COPY �o� 5 418 c 4 _ �a 5 5 I i OFFICE 426 DEMOLITION P 1. OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS OF SAME IN CONTRACT PRICE, IF REQUIRED. 2. FURNISH ALL LABOR AND MATERIALS/EQUIPMENT AS REQUIRED TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. 3. PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS FROM EMANATING FROM DEMOLITION/ CONSTRUCTION AREA. KEEP AREA CLEAN. 4. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN QUESTION WITH THE ARCHITECT BEFORE PROCEEDING. 5. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE DISPOSED OF PER BUILDING MANAGEMENT. 6. DEBRIS REMOVAL MUST BE PERFORMED USING THE FREIGHT ELEVATOR. CONTACT THE BUILDING MGMT. OFFICE TO OBTAIN SCHEDULE FOR THE USE OF THE FREIGHT ELEVATOR(S) PRIOR TO SUBMITTING BID. ALL DEBRIS REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT REQUIREMENTS AND PROCEDURES. 7. ALL DOORS, FRAMES, HARDWARE, MECHANICAL ITEMS, PLUMBING FIXTURES, LIGHT FIXTURES (INCLUDING DOWNLIGHTS & FLUORESCENTS), & SPECIAL EQUIPMENT SHOWN TO BE REMOVED, SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED, SAVED AND RE -USED AS DIRECTED HEREIN, RETURNED TO BUILDING STOCK OR DISPOSED OF AS DIRECTED BY BLDG. MGMT. S. THE ELECTRICAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHT AND POWER IN THE SPACE DURING CONSTRUCTION. 9. CAREFULLY REMOVE ALL EXISTING LIGHT FIXTURES AND LENSES (WHERE DEMOLITION IS NOTED AND STORE FOR FUTURE USE. BEFORE INDICATED RE -INSTALLATION, INSPECT EACH FIXTURE AND REPAIR OR REPLACE PARTS AS REQUIRED. ALL RELOCATED FIXTURES SHALL BE IN FULL OPERATING ORDER. ALL TUBES AND/OR BALLASTS NOT REUSED SHALL BE DISPOSED OF IN A PROPER MANNER. 5 OPEN OFFICE 419 0 LAN NOTES 01 OPEN OFFICE OFFICE OFFICE 415 414 413 10. IN PARTITIONS TO BE REMOVED, REMOVE AND CAP ALL OUTLETS, SWITCHES, WIRES, THERMOSTATS, ETC. TO THEIR SOURCE AS REQUIRED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND/OR REPAIRING ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS TO EXISTING CONSTRUCTION IN ELEVATOR LOBBY, PUBLIC CORRIDORS, RESTROOMS OR TENANT SPACES, REFINISH TO MATCH EXISTING ADJACENT FINISH, OR AS NOTED HEREIN. 12. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS. NO ACTIVE SMOKE DETECTOR SHALL BE COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN IT'S INTENDED PURPOSE. 13. ALL EXISTING FLOOR MOUNTED OUTLETS, WHERE NOTED TO BE REMOVED OR RELOCATED, SHALL BE CAPPED OFF TO THE NEAREST JUNCTION BOX. FILL AND LEVEL FLOOR TO ACCEPT NEW FLOOR COVERING. 14. RE -USE OR RELOCATE ALL ABOVE CEILING DUCTWORK, DIFFUSERS, GRILLES, SPRINKLER PIPES OR OTHER EQUIPMENT, AS REQUIRED FOR PROPER DISTRIBUTION WITH NEW LAYOUT. 15. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES, SERVICE OWNER OR TENANT DATA/COMMUNICATIONS REPRESENTATIVE AS REQUIRED TO PREVENT NEW CONSTRUCTION DELAYS. 16. REMOVE ALL EXISTING IRREGULAR MATERIALS WHICH CAUSE RISES OR DEPRESSIONS IN FLOORING SURFACE, SUCH AS FASTENERS, OUTLET CORES, COVER PLATES, RESILIENT FLOOR COVERINGS, CARPET, CARPET PAD, FLASH PATCH, CONCRETE FILL, PLYWOOD, ETC. 17. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DRAWINGS. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO COMPLETE THE WORK IN ACCORDANCE WITH THE CONTRACT DRAWINGS. 18. STAIRWAYS MUST REMAIN ACCESSIBLE AT ALL TIMES DURING DEMOLITION. OFFICE i 412 it 4 i DEMOLITION/PARTITION PLAN I DOOR &FRAME TYPES DOOR FRAME TO MATCH EAST. ADJACENT FRAME, DOOR AND BORROWED LIGHT TO MATCH EAST. ADJACENT FRAME TYPE 1 FRAME TYPE 2 DOOR TYPE B & C PARTITION ANNOTATION TYPES NEW DOOR A NEW PARTITION 17- 1 GLASS SIDELITE (WITH SILL) DOOR TYPE HARDWARE SET EXISTING DOOR TO REMAIN EXISTING PARTITION TO REMAIN EXISTING DOOR TO BE REMOVED EXISTING PARTITION OR MILLWORK TO BE REMOVED 1/811=1 I-011 CONSTRUCTION PLAN NOT 1. GENERAL NOTES SHEET NOTES 1. PARTITION DIMENSIONED TO FINISH FACE U.O.N. IOR PARTITION LOCATIONS SHALL BE AS SHOWN ON PARTITION PLAN. IN A 3. SEE SHEET 02A-8.0 FOR TYPICAL PARTITIONS O NEW SOFFIT TO BE INSTALLED WHERE EXISTING WALL IS DEMOLISHED. CASE OF CONFLICT NOTIFY ARCHITECT. PARTITION PLAN BY ARCHITECT DETAILS. REFER TO 04A-3.0 T AKES PRECEDENCE OVER ALL OTHER PLANS. O EXISTING DOOR, SIDELIGHT TO BE REMOVED AND SALVAGED FOR REUSE. REFER TO SHEET AN.1 FOR ADDITIONAL NOTES, LEGENDS, SYMBOLS, 3. ALL WALLS ARE EXISTING TO REMAIN EXCEPT WHERE DEMOLITION IS A -L GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH INDICATED ON THE PLAN. O NOT USED. WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH 4. ALL NEW WALLS ARE TYPE "A" UNLESS NOTED OTHERWISE. 5. NEW DOORS, FRAMES AND HARDWARE TO MATCH EXISTING IN HEIGHT ® EXISTING WALL TO BE MODIFIED AS NECESSARY TO WALL TYPE "C". SEE REFER TO POWER & SIGNAL AND REFLECTED CEILING PLANS FOR LOCATIONS AND FINISH AND TYPE. A8.0 FOR DETAIL 6. WHERE NEW CONSTRUCTION IS INDICATED ON THE PLANS, EXISTING CARPET TO BE CAREFULLY LIFTED AND REMOVED AT TIME OF O CONTRACTOR TO PROVIDE AND INSTALL CORNER GUARDS; 4'H X 2"W. CONSTRUCTION AND THEN CAREFULLY REPLACED. FLOORS AND WALLS TO REFER TO SHEET 04A-4.0 FOR SPECIFICATION. 3. BE PATCHED AND PREPPED AS NECESSARY FOR ACCEPTANCE OF NEW FINISHES. © DEMOLISH EXISTING WALL TO ACCOMODATE NEW SCHEDULED DOOR. 14. OBTAIN APPROVAL FROM ARCHITECT PRIOR TO MODIFYING COLUMN FURRING, PARTITION TYPE SYMBOLS n PARTITION TYPE "A" - SEE 1, A-8.0 RELOCATING PIPES AND SIMILAR SYSTEMS AND ITEMS, ADJUSTING r NEW FLOOR TO CEILING ACOUSTICAL " '`' PARTITION (2 1/2" STUDS) D MENSIONS NOTED "CLEAR" OR "CLR" MUST BE ACCURATELY DOOR NOTES ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR PIPING SHALL BE 4 PARTITION TYPE "C" - SEE 3, A-8.0 MAINTAINED, AND SHALL NOT VARY MORE THAN f 1/8" NEW SLAB TO SLAB ACOUSTICAL PARTITION 1. THE MAXIMUM FORCE TO PUSH OR PULL A DOOR SHALL BE 5 LBF (22N) W THOUT WRITTEN INSTRUCTION FROM ARCHITECT. (2 1/2" STUDS) AND FIRE CODES. 5. D MENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER `FAN 2. ALL DOORS USED IN CONNECTION WITH EXITS ARE READILY OPENED DOOR & HARDWARE TYPES WITHOUT A KEY FROM THE SIDE FROM WHICH EGRESS IS MADE 3. DOORS OPENING INTO REQUIRED EXIT CORRIDORS DO NOT RESTRICT -DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. BUILDING STANDARD 3'-0" X FULL HEIGHT. 1-3/4" SOLID CORE WOOD THE REQUIRED WIDTH WHEN OPENED IN ANY POSITION DOOR WITH BORROWED LIGHT TO MATCH EXIST. AT OFFICE 417. FRAME 4. SPECIFICATIONS ARE NOT SPECIFIC AS TO THE HAND, BACKSET OR VARIATIONS IN FLOOR ELEVATION EXIST, DOORS SHALL BE ORDERED WITH TYPE 2. REFER TO 5/A8.1, 6/A8.1, 7/A8.1, 8/A8.1 AND 9/A8.1 METHOD OF FASTENING OF HARDWARE; THE CONTRACTOR IS TO REVIEW C BUILDING STANDARD 3'-0" X FULL HEIGHT. 1-3/4" SOLID CORE WOOD THE APPLICATION HARDWARE ET WITHTHE DOORSIZETOVERIFY PROPER ACE OF SILL, U.O.N. DOOR FRAME TYPE 1. REFER TO 5/A8.1 AND 6/A8.1 EXISTING DOOR, FRAME AND HARDWARE TO REMAIN. E 5. ALL DOORS REQUIRED AS EXITS SHALL SWING IN THE DIRECTION OF TRAVEL ALL GLASS SHALL BE CLEAR TEMPERED GLASS, UNLESS OTHERWISE 7. 6. ALL ELECTRONIC HARDWARE SHALL BE TIED INTO THE LIFE SAFETY UQ ANTITY DESCRIPTION SYSTEM N THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION 7. ALL HARDWARE SHALL BE CYLINDER TYPE LOCK AND LATCH SETS 4 EACH BUTT HINGES 2 1 EACH PASSAGE FUNCTION LATCHSET WITH LEVER HANDLE 8. ALL DOORS WITH LOCK SETS AND LATCH SETS SHALL HAVE A LEVER 18. 1 EACH DOME STYLE FLOOR STOP HANDLE ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM. 3 EACH SILENCER WITH NO JOINTS VARYING MORE THAN 1/8" OVER 6'-0" AND NO I DOOR &FRAME TYPES DOOR FRAME TO MATCH EAST. ADJACENT FRAME, DOOR AND BORROWED LIGHT TO MATCH EAST. ADJACENT FRAME TYPE 1 FRAME TYPE 2 DOOR TYPE B & C PARTITION ANNOTATION TYPES NEW DOOR A NEW PARTITION 17- 1 GLASS SIDELITE (WITH SILL) DOOR TYPE HARDWARE SET EXISTING DOOR TO REMAIN EXISTING PARTITION TO REMAIN EXISTING DOOR TO BE REMOVED EXISTING PARTITION OR MILLWORK TO BE REMOVED 1/811=1 I-011 CONSTRUCTION PLAN NOT 1. DO NOT SCALE DRAWINGS, WRITTEN DIMENSIONS GOVERN. ALL 11. REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS AND IOR PARTITION LOCATIONS SHALL BE AS SHOWN ON PARTITION PLAN. IN A PLENUM BARRIER LOCATIONS. C CASE OF CONFLICT NOTIFY ARCHITECT. PARTITION PLAN BY ARCHITECT I T AKES PRECEDENCE OVER ALL OTHER PLANS. 12. REFER TO SHEET AN.1 FOR ADDITIONAL NOTES, LEGENDS, SYMBOLS, 2. A -L GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH ABBREVIATIONS, AND SCHEDULES. WITH NO VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR ADJOINING SURFACES WHERE REQUIRED. ALL 13. REFER TO POWER & SIGNAL AND REFLECTED CEILING PLANS FOR LOCATIONS SJRFACES SHALL BE ALIGNED AND SANDED SMOOTH. OF SWITCHES, OUTLETS AND THE LIKE TO BE REMOVED. PATCH AND REPAIR PARTITION TO MATCH ADJACENT SURFACE AND FINISH. 3. A_L PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO =_ NISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL 14. OBTAIN APPROVAL FROM ARCHITECT PRIOR TO MODIFYING COLUMN FURRING, D MENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND SHALL RELOCATING PIPES AND SIMILAR SYSTEMS AND ITEMS, ADJUSTING A -LOW FOR THICKNESSES OF ALL WALL FINISHES, U.O.N. ANY AND ALL OTHER FIELD CONDITIONS REQUIRED TO FIT PLANS. 4. D MENSIONS NOTED "CLEAR" OR "CLR" MUST BE ACCURATELY 15. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR PIPING SHALL BE MAINTAINED, AND SHALL NOT VARY MORE THAN f 1/8" FULLY PACKED AND SEALED IN ACCORDANCE WITH THE APPLICABLE BUILDING W THOUT WRITTEN INSTRUCTION FROM ARCHITECT. AND FIRE CODES. 5. D MENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER `FAN 16. TRIM THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED FLOOR, 2 INCHES FROM INDICATED DIMENSION, U.O.N. VERIFY FIELD AS APPLICABLE, BY 1/4" INCH MAXIMUM, UNLESS OTHERWISE NOTED. VERIFY -DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SLAB CONDITIONS. TRIM EACH DOOR TO FIT CONDITION. WHERE RADICAL SECURE ARCHITECT'S APPROVAL. VARIATIONS IN FLOOR ELEVATION EXIST, DOORS SHALL BE ORDERED WITH 6. A_L DIMENSIONS TO THE EXTERIOR WINDOW WALL ARE TO THE INSIDE BOTTOM STILE SIZED TO ACCOMODATE THESE UNDERCUT CONDITIONS. ACE OF SILL, U.O.N. 17. ALL GLASS SHALL BE CLEAR TEMPERED GLASS, UNLESS OTHERWISE 7. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS NOTED. GLAZING TONG MARKS SHALL NOT BE VISIBLE. CLEAN AND N THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION POLISH ALL GLASS PRIOR TO PROJECT DELIVERY. PARTITION OF THE LAYOUT, NOTIFY THE ARCHITECT. VERIFICATION OF THE LAYOUT TO BE PROVIDED BY THE ARCHITECT PRIOR TO PARTITION INSTALLATION 18. CLG. HT. PARTITIONS SHALL BE INSTALLED TIGHT TO FINISHED CLG; 8. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE METAL EDGE TRIM. WITH NO JOINTS VARYING MORE THAN 1/8" OVER 6'-0" AND NO JOINTS GREATER THAN 3/16", U.O.N. 9. ASL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE, AND IN PROPER ALIGNMENT. 19. DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. U.O.N. 10. REFER TO MILLWORK SHOP DRAWINGS FOR SPECIFIC DETAILS OF COORDINATION 3_TWEEN DRYWALL/MILLWORK CONDITIONS. SOLID CORE MOOD VENEER DOOR TO MATCH EXIST. ADJACENT SURFACE MOUNTED FIRE EXTINGUISHER ALIGN ES 20. "ALIGN" MEANS TO ACCURATELY LOCATE FINISHED FACES IN THE SAME PLANE. 21. ALL MILLWORK TO BE FASTENED TO THE PARTITION. PROVIDE BLOCKING FOR ALL MILLWORK NOT SUPPORTED BY SLABS OR ABOVE 4'-0" HT. ALL CONCEALED LUMBER & BLOCKING TO BE FIRE TREATED. 22. ALL DOORS SHALL HAVE 1'-6" CLR. ON STRIKE/PULL SIDE OF DOOR. VERIFY AND ADVISE ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS. 23. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR: • GLAZING • MILLWORK • DOORS/FRAMES INDIANAPOLIS LEGAL 11611 N. MERIDIAN ST. CARMEL, IN 46032 4TH FLOOR 3 ISSUE FOR CONSTRUCTION DESIGN RELEASE 05/17/04 2 ISSUE FOR PRICING 04/19/04 1 ISSUE FOR CLIENT REVIEW 04/05/04 Issue Description Date I�IN TE R IOR A R C H I T EC TS ® 2004 IA, Inc. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT, Drawn: ESM Check: KSY Owner Approva ]ob No: 054110.00 Scale, 1/8 -T 0' DEMOLITION/ PARTITION Title: PLAN N 0 Sheet: ■ ii a I a I I I I 0 N w I I I 0 a a !f 0 I I I NJ% OPEN J� OFFICE AREA 423 FlTl 3 2 O CONFERENCE 425 e OFFICE 426 FINISH PLAN NOTES NO PAINTING OR INTERIOR FINISHING SHALL BE DONE UNDER CONDITIONS WHICH WILL JEOPARDIZE THE QUALITY OR APPEARANCE OF SUCH WORK. ALL WORKMANSHIP WHICH IS JUDGED LESS THAN FIRST QUALITY BY THE ARCHITECT WILL BE REJECTED. ALL COLORS ARE TO BE SELECTED BY THE ARCHITECT, U.O.N. ALL SURFACES SHALL BE PREPARED TO RECEIVE THE SPECIFIED FINISH. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH AND PREPARED TO RECEIVE THE SPECIFIED FINISH. PAINT GRADE WOODWORK SHALL BE HAND SANDPAPERED BETWEEN COATS AND DUSTED CLEAN. ALL HOLES, PITCH POCKETS OR SAPPY PORTIONS SHALL BE SCRAPED AND SHELLACKED, OR EALED WITH KNOT SEALER. NAIL HOLES, CRACKS OR DEFECTS SHALL BE PUTTIED AFTER FIRST COAT, WITH PUTTY MATCHING COLOR OF STAIN OR PAINT FINISH. REMOVE OIL OR GREASE WITH MINERAL SPIRITS. ALL CRACKS, HOLES, IMPERFECTIONS IN EXISTING WALLS, PARTITIONS OR GYPBOARD SHALL BE FILLED WITH PATCHING PLASTER AND SMOOTHED OFF TO MATCH ADJOINING SURFACES. INTERIOR GYPSUM BOARD SURFACES SHALL BE WIPED WITH A DAMP CLOTH JUST PRIOR TO APPLICATION OF THE FIRST COAT, IN ORDER TO LAY FLAT ANY NAP WHICH MAY HAVE FORMED IN SANDING PROCESS. UPON COMPLETION REMOVE ALL PAINT FROM WHERE IT HAS SPILLED, SPLASHED OR SPLATTERED ON EXPOSED ADJACENT SURFACES. ALL VENEER STAINS SHALL HAVE UNIFORM COLOR. EXAMINE ALL FINISH SURFACES AFTER COMPLETION OF WORK INCLUDING WOOD FLOORING AND MILLWORK INSTALLATION AND PROCEED WITH "TOUCH-UP" AS REQUIRED. PROVIDE ARCHITECT WITH A MINIMUM OF (3) 8" X 10" BRUSH -OUTS OF EACH COLOR & FINISH FOR ARCHITECT'S APPROVAL AT LEAST 2 WEEKS PRIOR TO SITE APPLICATION. ON-SITE APPLICATION WILL BE REQUIRED ONE WEEK PRIOR TO FINAL APPROVAL. ARCHITECT RESERVES THE RIGHT TO ADJUST ANY COLOR/FINISH ONCE THE WALL TEST HAS BEEN MADE. UNDERSIDE OF SOFFITS (WHERE OCCURS) TO RECEIVE A FINISH TO MATCH ADJACENT VERTICAL FINISH, U.O.N. ELECTRICAL SWITCH AND OUTLET COVER PLATES. SURFACE HARDWARE, ETC. SHALL BE INSTALLED AFTER PAINTING AND/OR APPLICATION OF WALLCOVERINGS & CARPET SPECIFIED. P C B P C B 1 OFFICE OFFICE 428 429 OPEN OFFICE AREA 427 P C B 1 1 1 FILE AREA 420 P C B 1 1 1 000 P c B i 1 OPEN OFFICE 419 0 ® / j, COPY //// 418 OPEN OFFICE OFFICE 415 414 12. PRIOR TO SITE APPLICATION, PROVIDE ARCHITECT WITH 8" X 10" SAMP! E CUTTINGS FROM ACTUAL DYE LOTS OF ALL SPECIFIED WALLCOVERLNGS �C ARCHITECT'S APPROVAL AND PROVIDE EXPECTED DELIVERY DATE TO .,OB 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ALLOWING FOR DELIVERY _EAE FOR ALL FABRICS AND OTHER CUSTOM FINISHES WITHIN THE CONSTRl_,CT SCHEDULE. ALL DELIVERY TIMES MUST BE CONFIRMED, AND ANY EXCESSI TIME MUST BE BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATEL" FOR RE -SPECIFICATION IF NECESSARY. 14. MODIFY EXISTING FLOOR SURFACES AS REQUIRED TO INSTALL NEW '=_OOf MATERIALS, THUS PREVENTING NOTICEABLE LUMPS OR DEPRESSIONS. 15. ALL AREAS, EXCEPT AS SPECIFICALLY NOTED, SHALL RECEIVE CARPET. 16. ALL PARTITIONS, COLUMNS, AND MILLWORK TO RECEIVE STRAIGHT RES-7- BASE ES-BASE OR CARPET, COVE RESILIENT BASE AT RESILIENT FLOORING, U.O.N. 17. SEE FINISH PLAN, ELEVATIONS AND DETAILS FOR CLARIFICATION OF EX -E-1 FINISH MATERIALS. 18. PAINT CEILING ACCESS PANELS WHERE THEY OCCUR TO MATCH ADJACE-\_ CEILING FINISH. 19. STAINED AND PAINTED SURFACES SHALL BE FINISHED SUCH THAT _0\ - NOT VISIBLE WHEN VIEWED FROM ANY REASONABLE ANGLE. 20. WALLCOVERING SEAMS ARE NOT TO OCCUR WITHIN 1'-0" Or CORNERS. APPLY FABRIC SO WALL IS DIVIDED WITH A MINIMUM NUMBER OF SEA'VS, WITH EQUAL WIDTH PANELS U.O.N. 21. ALL INTERSECTIONS OF FLOOR FINISH MATERIALS SHALL BE LOCATED D z� UNDER CENTER OF DOOR, WHERE OCCURS, U.O.N. 22. ALL OPEN CABINETRY SHALL BE PLASTIC LAMINATE ON AuL EXPOSED S_, U.O.N. APPLY WHITE MELAMINE TO INTERIOR OF CABINETRY WITH DOORS DRAWERS, U.O.N.. 23. SUBMIT CARPET SEAMING PLAN TO ARCHITECT PRIOR TO ORDERING AND (4) WEEKS PRIOR TO INSTALLATION FOR ARCHITECT'S REVIEW AND APzDR-- 24. EXISTING FINISHES IN CORE AREAS TO REMAIN, U.O.N. 25. COORDINATE WINDOW COVERING, CONTROL LOCATION AND INSTALLATION WITH ARCHITECT. NO CONTROLS TO BE PLACED MORE THAN 48" AFF. 26. COORDINATE CORRIDOR FINISHES WITH BUILDING MANAGEMENT. OFFICE OFFICE 413 412 ♦ � FINISH PLAN ) O O 1/8"=l1 - 0" P�;r -41"• Liberty -2 mutu I-Im INDIANAPOLIS LEGAL 11611 N. MERIDIAN ST. CARMEL, IN 46032 4TH FLOOR 3 ISSUE FOR CONSTRUCTION DESIGN RELEASE 05/17/04 2 ISSUE FOR PRICING 04/19/04 1 ISSUE FOR CLIENT REVIEW 04/05/04 Issue Description Date I N T E FINISH SCHEDULE AR FINISH LEGEND GENERAL NOTES ECTS BASE OTHER R SITE. cc MANUFACTURER: IPC FINISH DESIGNATION RB FINISH NUMBER B 1. EXISTING FINISHES TO REMAIN UNLESS NOTED OTHERWISE. B MANUFACTURER: VINYL BASE TO MATCH EXISTING B TIMES LOCATION ADJACENT THROUGHOUT U.O.N. STYLE NAME: 160 2. WHERE SPECIFIED, CONTRACTOR SHALL PROVIDE STRAIGHT RESILIENT BASE AT ON4' COLOR. TO MATCH EXISTING HIGH X 2" WIDE 90 FLUSH MOUNT CORNER FLOOR FINISH CHANGE CARPET. ✓E LEAD GUARDS 3. SEE POWER & COMMUNICATIONS PLAN FOR RECEPTACLE/SWITCH COVER PLATE ALLOW LOCATION: ALL OUTSIDE CORNERS, U.O.N. FINISH. 4. CONTRACTOR TO PROVIDE AND INSTALL CORNER GUARDS ON ALL 'ING OUTSIDE CORNER LOCATIONS. REFER TO FINISH SCHEDULE AND SHEET 04A-1.0 ENLARGED PLAN COPY 418 5. TOUCH UP/REPAINT EXISTING WALLS AS REQUIRED WHERE NEW CONSTRUCTION OCCURS. FLOOR NT 6. WHERE NEW CONSTRUCTION IS INDICATED ON THE PLANS, EXISTING �c EXISTING CARPET TO REMAIN 1-� MANUFACTURER: SHAW CARPET TO BE CAREFULLY LIFTED AND REMOVED AT TIME OF IT OF STYLE NAME: 97540 i I CONSTRUCTION AND THEN CAREFULLY REPLACED. FLOORS AND WALLS TO COLOR: STAINLESS N BE PATCHED AND PREPPED AS NECESSARY FOR ACCEPTANCE OF NEW LOCATION: CA ION. THROUGHOUT U.O.N. �EAA L FINISHES. 3 ARE _ — — I .rm �...... t„._ — — .� SHEET NOTES P B I I I ( NOT USED. AND I I WALL =CTLY e P MANUFACTURER: POLOMYX e ',FACES STYLE NAME: TYPE: BLU 22W WATER BASED I I COPY I2 O EXISTING CARPET TO BE REPLACED WITH ATTIC STOCK WHERE DEMOLITION AND LOCATION: THROUGHOUT, U.O.N.I I OCCURS. FLOORS TO BE PATCHED AND PREPPED FOR ACCEPTANCE OF \T LEAST VAL. eMANUFACTURER: 2 BENJAMIN MOORE 418 P e I I NEW FINISHES. 3O CONTRACTOR TO FEATHER PAINT APPLICATION AT THIS POINT TO BLEND WITH EXISTING WALL PAINT. COLOR: TO MATCH EXISTING I )F SAME TYPE: LOCATION: SEMI GLOSS I ® SEE ENLARGED PLAN ON SHEET 04A-4.0 FOR FINISHES DOOR AND BORROWED LIGHT FRAMES.NIfin / P�;r -41"• Liberty -2 mutu I-Im INDIANAPOLIS LEGAL 11611 N. MERIDIAN ST. CARMEL, IN 46032 4TH FLOOR 3 ISSUE FOR CONSTRUCTION DESIGN RELEASE 05/17/04 2 ISSUE FOR PRICING 04/19/04 1 ISSUE FOR CLIENT REVIEW 04/05/04 Issue Description Date ® 2004 IA, Inc. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. DrawnF jM CheckKSY Owner Approval: Job No054M.00 Scaled/8'=T-O' FINISH PLAN Title: N O J) Sheet: ■ m m I a 0 I r I N T E R 10 R AR CH IT ECTS ® 2004 IA, Inc. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. DrawnF jM CheckKSY Owner Approval: Job No054M.00 Scaled/8'=T-O' FINISH PLAN Title: N O J) Sheet: ■ m m I a 0 I r 1 PARTITION TYPE "A " ACOUSTICAL PARTITION 3" = 1'-0" 2 i ------------- 'a I � - I I I I I - - TYPICAL DOOR HEAD 3" = 1'-0" 6 TYPICAL JAMB DETAIL 5 IN PARTITION TYPE A - EQ'-_ -. f _ EQ' L 'C I, .r - r 3 PARTITION TYPE C ACOUSTICAL PARTITION 3" =1'-0" 4 -_ _ 1'-6 SIDE L 3" = 1'-0" 7 TYPICAL NON FULL HEIGHT GLASS SIDELITE HEADER 3" = 1'-0" 8 TYPICAL JAMB DETAIL W/ GLASS SIDELITE _ -�-F -- - --E ARCHITECTS 9 TYPICAL GLASS SILL DETAIL 3" = 1'-0" 10 TYPICAL PARTITION CENTERED MULLION N.T.S. 11 TYPICAL CEILING TRANSITION 3" =1'-0" 12 Liberty-,Mutuat, INDIANAPOLIS LEGAL 11611 N. MERIDIAN ST. CARMEL, IN 46032 4TH FLOOR Drawn k JM Check: KY Owner Approval: Job No: 054110.00 Scde:1/8'-]'-0' Tale: DETAILS Sheet I I I 3 ISSUE FOR CONSTRUCTION DESIGN RELEASE 05/17/04 2 ISSUE FOR PRICING 04/19/04 1 ISSUE FOR CLIENT REVIEW 04/05/04 Issue Description Date 3" = 1'-0" I NTE R 1 0 R ARCHITECTS 4- y ® 2004 IA, Inc. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, AND THE SAME MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. r • P Drawn k JM Check: KY Owner Approval: Job No: 054110.00 Scde:1/8'-]'-0' Tale: DETAILS Sheet I I I